AC 150/5320-15A Management Of Airport Industrial Waste

Provides basic information on the characteristics, management, and regulations of industrial wastes generated at airports. Provides guidance for the development of a Storm Water Pollution Prevention Plan (SWPPP) that applies best management practices to eliminate, prevent, or reduce pollutants in storm water runoff associated with particular airport industrial activities.

Official source ↗ Open PDF

U.S. Department of Transportation Federal Aviation Administration

Advisory Circular

Subject: MANAGEMENT OF AIRPORT

INDUSTRIAL WASTE

Date: 9/8/2008 Initiated by: AAS-100

AC No: 150/5320-15A Change:

1. PURPOSE. This advisory circular (AC) provides basic information on the characteristics, management, and regulations of industrial wastes generated at airport and guidance for the development of a Storm Water Pollution Prevention Plan (SWPPP) that applies best management practices to eliminate, prevent, or reduce pollutants in storm water runoff associated with particular airport industrial activities.

2. CANCELLATION. This AC cancels AC 150/5320-15, Management of Airport Industrial Waste, dated February 11, 1991, and Change 1, dated April 22, 1997.

3. APPLICATION. The guidelines and recommendations contained in this AC are recommended by the Federal Aviation Administration (FAA) for the management of airport generated wastes at civil airports. This AC offers general guidance for managing airport industrial waste and is not binding or regulatory.

4. PRINCIPAL CHANGES. The following principal changes are incorporated:

a. The vast majority of chapter 8 was replaced by referencing the Airport Cooperative Research Program (ACRP) document ARCP #02-02, Planning Guidelines and Best Management Practices for Aircraft and Airfield Deicing Stormwater Management Systems.

b. The concept of waste minimization and recycling deicing fluids.

c. The addition of supplementary Pollution Prevention techniques at airports.

d. The distinction between hazardous waste and non-hazardous waste.

Michael J. O’Donnell Director, Airport Safety and Standards

Intentionally left blank.

TABLE OF CONTENTS

CHAPTER 1. INTRODUCTION … 1

1.1. BACKGROUND … 1 1.2. AIRPORT INDUSTRIAL WASTES … 1 1.3. INDUSTRIAL WASTEWATER REGULATIONS AND WATER QUALITY STANDARDS … 1 1.4. HAZARDOUS AND NON-HAZARDOUS WASTE REGULATIONS … 2 1.5. DE/ANTI-ICING AND STORM WATER OCCURRING WASTES … 2 1.6. DEVELOPING A STORM WATER POLLUTION PREVENTION PLAN … 2

CHAPTER 2. HAZARDS AND NUISANCES OF AIRPORT INDUSTRIAL WASTE … 5

2.1. CHARACTERISTICS … 5 2.2. INTERFERENCE WITH WATERWAY PURIFICATION OR POTW OPERATION....5 2.3. CONTAMINATION OF GROUND WATER … 6

CHAPTER 3. TYPES OF AIRPORT INDUSTRIAL WASTE … 7

3.1. CLASSIFICATION … 7 3.2. CYANIDES … 7 3.3. CHROMIUM COMPOUNDS AND TOXIC METALS … 7 3.4. ACIDS AND ALKALIES … 8 3.5. ORGANIC SOLVENTS AND PHENOLS … 8 3.6. OIL, GREASE, AND/OR DETERGENTS … 8 3.7. BATTERIES … 8 3.8. DE/ANTI-ICING CHEMICAL WASTES … 8

CHAPTER 4. SURVEYS FOR AIRPORT INDUSTRIAL WASTE … 9

4.1. OBJECTIVES OF A WASTE SURVEY … 9 4.2. REQUIREMENTS OF WASTE SURVEY … 9 4.3. FLOW MEASUREMENT … 9 4.4. SAMPLING … 9 4.5. ANALYSIS … 9 4.6. STORMWATER POLLUTION PREVENTION DEVELOPMENT ASSESSMENT ....10

CHAPTER 5. MANAGEMENT STRATEGIES FOR AIRPORT INDUSTRIAL WASTE … 11

5.1. MANAGEMENT STRATEGIES … 11 5.2. SOURCE REDUCTION … 11 5.3. RECOVERY AND REUSE … 11 5.4. TREATMENT … 12

CHAPTER 6. MANAGEMENT OF HAZARDOUS AND NON-HAZARDOUS WASTE … 13

6.1. HAZARDOUS WASTES … 13 6.2. GENERATOR STATUS … 13 6.3. GENERATOR IDENTIFICATION NUMBER … 13 6.4. ACCUMULATION TIME … 14 6.5. ACCUMULATION UNITS … 14 6.6. ONSITE TREATMENT AND DISPOSAL … 15 6.7. MANIFESTS … 16 6.8. PERSONNEL TRAINING, PREPAREDNESS AND PREVENTION, AND CONTINGENCY PLANS AND EMERGENCY PROCEDURES … 16

iii

6.9. EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW … 17

CHAPTER 7. AIRPORT INDUSTRIAL WASTES CONVEYANCE AND COLLECTION … 19

7.1. CONVEYANCE SYSTEMS … 19 7.2. SEWER MATERIALS … 19 7.3. COLLECTION SYSTEMS … 19

CHAPTER 8. MANAGEMENT OF DE/ANTI-ICING CHEMICAL WASTES … 21

8.1. GENERAL GUIDANCE … 21 8.2. AIRCRAFT DEICING FACILITIES … 21 8.3. RUNWAY SURFACE CONDITION MONITORING SYSTEMS … 21 8.4. LAGOONS AND RETENTION PONDS … 21

CHAPTER 9. TREATMENT TECHNIQUES FOR INDUSTRIAL WASTEWATERS … 23

9.1. GENERAL … 23 9.2. PHYSICAL UNIT OPERATIONS … 23 9.3. CHEMICAL UNIT OPERATIONS … 24 9.4. MEMBRANE PROCESSES … 25 9.5. BIOLOGICAL UNIT OPERATIONS … 26 9.6. TERTIARY AND OTHER TREATMENT TECHNOLOGIES … 29 9.7. TREATABILITY STUDIES … 30 9.8. SLUDGE HANDLING … 30

CHAPTER 10. MANAGEMENT OF MAINTENANCE SHOP WASTES … 31

10.1. GENERAL … 31 10.2. PLATING ROOM WASTES … 31 10.3. SOURCES AND CHARACTERISTICS OF WASTES … 31 10.4. PLATING WASTE REDUCTION … 31 10.5. CHROMIC ACID RECOVERY … 31 10.6. CHROMIUM REDUCTION … 32 10.7. PHENOLIC WASTES … 33 10.8. CYANIDE WASTES … 34 10.9. PAINTING AND PAINT REMOVAL OPERATION … 35 10.10. OILY WASTES … 36

CHAPTER 11. MANAGEMENT OF AIRCRAFT WASHES AND SIMILAR WASTES … 37

11.1. GENERAL … 37 11.2. WASTE CONTRIBUTORS … 37 11.3. AIRCRAFT WASH WASTES TREATMENT AND DISPOSAL … 37 11.4. SLUDGE DISPOSAL … 37

CHAPTER 12. AIRPORT-ORIENTED STORM WATER POLLUTION PREVENTION PLANS

(SWPPPs) … 39 12.1. INTRODUCTION … 39 12.2. ORGANIZATION … 39 12.3. ACCIDENTS OR INCIDENTS ON THE AIRPORT … 40 12.4. USEPA GUIDANCE MANUALS … 40

SECTION 1. PLANNING AND ORGANIZATION (PHASE 1) … 40

12.5. INTRODUCTION … 40

iv

12.6. POLLUTION PREVENTION TEAM … 40 12.7. REFERENCING OTHER PLANS … 41 12.8. SPECIAL REQUIREMENTS AND DUTIES … 41

SECTION 2. ASSESSMENT (PHASE 2) … 42

12.9. INTRODUCTION … 42 12.10. DEVELOPING AN AIRPORT FACILITY SITE MAP … 42 12.11. MATERIAL INVENTORY AND DESCRIPTION OF EXPOSED SIGNIFICANT MATERIALS … 43 12.12. LIST OF PAST SIGNIFICANT SPILLS AND LEAKS … 44 12.13. NON-STORM WATER DISCHARGES ASSESSMENT AND CERTIFICATION … 45 12.14. STORM WATER MONITORING AND SAMPLING DATA … 46 12.15. SITE EVALUATION SUMMARY … 47

SECTION 3. BEST MANAGEMENT PRACTICES (BMP) IDENTIFICATION (PHASE 3) .48

12.16. INTRODUCTION … 48 12.17. GOOD HOUSEKEEPING … 49 12.18. PREVENTIVE MAINTENANCE PRACTICES … 51 12.19. SPILL PREVENTION AND RESPONSE PROCEDURES FOR AIRPORT FACILITIES … 51 12.20. SPILL PREVENTION AND RESPONSE PROCEDURES FOR AIRCRAFT FUELING/DEFUELING ACTIVITIES … 52 12.21. SPILL PREVENTION AND RESPONSE PROCEDURES FOR GROUND VEHICLE FUELING … 53 12.22. SPILL PREVENTION AND RESPONSE PROCEDURES FOR DEICING/ANTI-ICING ACTIVITIES … 53 12.23. MATERIAL SUBSTITUTION … 56 12.24. AIRCRAFT, GROUND VEHICLE, AND EQUIPMENT WASH WATER … 56 12.25. AIRCRAFT, GROUND VEHICLE, AND EQUIPMENT MAINTENANCE AREAS...56 12.26. LOADING/UNLOADING DOCKS AND STORAGE AREAS … 57 12.27. SOIL EROSION AND SEDIMENTATION CONTROLS … 58

SECTION 4. PLAN IMPLEMENTATION (PHASE 4) … 59

12.28. INTRODUCTION … 59 12.29. EMPLOYEE TRAINING PROGRAMS … 59

SECTION 5. EVALUATION (PHASE 5) … 60

12.30. INTRODUCTION … 60 12.31. VISUAL INSPECTIONS … 61 12.32. RECORDKEEPING AND INTERNAL REPORTING … 62 12.33. REVISION OF SWPPPS … 63

SECTION 6. SPECIAL SWPPP REQUIREMENTS … 63

12.34. INTRODUCTION … 63 12.35. SPECIAL REQUIREMENTS FOR DISCHARGES THROUGH LARGE AND MEDIUM MUNICIPAL SEPARATE STORM SEWER SYSTEMS … 64 12.36. SPECIAL REQUIREMENTS FOR SARA TITLE III, SECTION 313 REPORTING FACILITIES … 64 12.37. SPECIAL REQUIREMENTS FOR SALT STORAGE PILES … 65

v

SECTION 7. GENERAL ADMINISTRATIVE REQUIREMENTS … 65

12.38. INTRODUCTION … 65 12.39. COMPLIANCE DEADLINES … 65 12.40. REQUIRED SIGNATURES … 66 12.41. DESIGNATING SIGNATORY AUTHORITY … 67 12.42. CERTIFICATION STATEMENT REQUIREMENT … 67 12.43. SARA TITLE III, SECTION 313 FACILITY PLAN CERTIFICATION REQUIREMENTS … 67 12.44. AVAILABILITY OF SWPPPS FOR PUBLIC ACCESS … 67 12.45. USEPA DIRECTOR REQUIRED SWPPP MODIFICATIONS … 68

APPENDIX A. ACRONYMS AND RELATED READING MATERIAL … 69

A.1. ACRONYMS … 69 A.2. RELATED READING MATERIAL … 71

APPENDIX B. FEDERAL PRIORITY POLLUTANT LIST … 73

APPENDIX C. WORKSHEETS FOR SWPPPS … 77

APPENDIX D. SAMPLE OF AN AIRPORT SWPPP … 89

APPENDIX E. SAMPLE OF AN EMERGENCY PLANNING & COMMUNITY RIGHT-TO-

KNOW ACT (EPCRA) SECTION 313 AIRPORT TENANT FACILITY SWPPP … 113

LIST OF FIGURES

Figure 9 - 1. Neutralization (continuous method) … 25 Figure 9 - 2. Neutralization (batch method) … 25 Figure 9 - 3. Reverse Osmosis (RO) … 27 Figure 9 - 4. Sequencing Batch Reactor (SBR) … 28 Figure 10 - 1. Chromic Acid Recovery … 32 Figure 10 - 2. Chemical treatment of chromium wastes … 33 Figure 10 - 3. Chemical oxidation of phenols … 34 Figure 10 - 4. Cyanide treatment … 35 Figure 11 - 1. Air flotation treatment system … 38

LIST OF TABLES

Table 12 - 1. Five phase approach for developing airport oriented SWPPPs … 40 Table 12 - 2. Equipment to inspect … 52 Table 12 - 3. Areas to inspect … 62 Table 12 - 4. Visual Inspection Checklist … 63 Table 12 - 5. USEPA general permit requirements … 64 Table 12 - 6. Specific Section 313 Facility Controls … 66

vi

INDUSTRIAL WASTEWATER REGULATIONS AND WATER QUALITY STANDARDS

CHAPTER 1. INTRODUCTION

1.1. BACKGROUND. In 1973, the Federal Aviation Administration (FAA) published advisory circular (AC) 150/5320-10, Environmental Enhancement at Airports - Industrial Waste Treatment, to address the subject of industrial waste management at airports. The Multi Sector General Permit (MSGP) currently authorizes storm water discharges associated with industrial activity for most areas of the United States where the National Pollutant Discharge Elimination System (NPDES) permit program has not been delegated. The guidance in this AC is based on the MSGP, which is used in non-delegated states, and which may be adopted or adapted by delegated states. Subsequently in 1991 and 1997, AC 150/5320-15, Management of Airport Industrial Waste, was issued to provide additional guidance for waste management at airports and for the development of a Storm Water Pollution Prevention Plan (SWPPP) that focused on best management practices to eliminate, prevent, or reduce pollutants in storm water runoff associated with particular airport activities. At the present time, the United States Environmental Protection Agency (USEPA) will issue a notice of proposed rule making in November 2008 relative to the management of airport storm water. This advisory circular is in response to the USEPA regulation proposal. It is noted that the worksheets in Appendix C and the example SWPPP may be modified on the basis of the final USEPA regulation governing storm water runoff. Appendix A provides related reading material.

1.2. AIRPORT INDUSTRIAL WASTES. Although airports are not usually considered as industrial complexes, daily activities, such as aircraft and ground vehicle washing and cleaning, fueling operations, aircraft maintenance and repair work (including painting and metalwork), engine test cell operations; de/anti-icing operations, and ground vehicle maintenance, are all sources of airport industrial wastes. Wastes generated by these activities that are addressed by this AC are categorized as either industrial wastewater, hazardous or non-hazardous wastes.

1.2.1. Industrial Wastewaters. Industrial wastewaters are generated during aircraft and ground vehicle washing, aircraft maintenance and repair work, and de/anti-icing operations. It is recommended that renters or leasee holders on airport property whose facilities generate industrial wastewater other than that expected from airport operations also comply with Federal, state, and local waste management regulations. Industrial wastewaters may be recycled, reused or discharged for treatment to onsite airport treatment systems or to an offsite Publicly Owned Treatment Works (POTW) or, for certain types of waste, discharged without treatment to surface waters. Wastes may also be sent offsite to commercial waste treatment facilities. This is explained in detail in Chapter 8. Because of their characteristics, industrial wastewaters are generally more difficult to treat than sanitary (domestic) sewage and represent a potentially significant threat to surface and ground water quality.

1.2.2. Hazardous Wastes. Hazardous and non-hazardous wastes may be generated during ground vehicle maintenance, aircraft cleaning, fueling operations, aircraft maintenance and repair work, and engine test cell operations. Management of hazardous wastes must strictly follow the most current stringent Federal, State and local regulations governing treatment, storage, and disposal (TSD). Paragraph 2.1 defines hazardous wastes.

1.2.3. Non-Hazardous Wastes. Non-hazardous waste must be disposed of in accordance with the acceptable Federal, State and local practices; for example, the discarding of oily rags or rags containing paints or solvents.

1.3. INDUSTRIAL WASTEWATER REGULATIONS AND WATER QUALITY STANDARDS. As provided under Section 303 of the Clean Water Act (CWA), Federal regulations require that all States develop water quality standards which have been approved by the USEPA. These

DEVELOPING A STORM WATER POLLUTION PREVENTION PLAN.

standards, which impact airports, are reflective of the effects of various pollutants upon the ultimate designated uses of the receiving water and are intended to maintain water quality at a level that adequately protects those uses. Numerous sections of the CWA outline provisions for other Federal regulations to ensure that State water quality standards are achieved. Regulations that can affect airports include the NPDES program (Section 402), Effluent Limitations (Section 301), National Standards of Performance (Section 306), and Toxic and Pretreatment Effluent Standards (Section 307). Section 403 of the CWA also outlines provisions for ocean discharge criteria. In addition to these Federal regulations, State and local regulations may impose additional, more stringent, standards for the discharge of airportgenerated industrial wastewaters. Airports are advised of the necessity to coordinate all planned airport industrial waste activities with these agencies prior to the implementation of any management programs.

1.4. HAZARDOUS AND NON-HAZARDOUS WASTE REGULATIONS. As provided under the Resource Conservation and Recovery Act (RCRA), Federal regulations require that all generators of hazardous waste, including airport facilities and airport lessees, follow specific procedures for the TSD of hazardous wastes. Under certain circumstances, materials that would ordinarily be considered hazardous are exempt from RCRA regulations when they are present in industrial wastewater that is discharged to a POTW.

1.5. DE/ANTI-ICING AND STORM WATER OCCURRING WASTES.

1.5.1. Regulations. Section 405 of the Water Quality Act of 1987 (WQA) added section 402(p) of the CWA, which directed the Environmental Protection Agency (EPA) to develop a phased approach to regulate storm water discharges under the NPDES program. The USEPA published a final regulation on the first phase on this program associated with industrial activity. EPA defined the term storm water discharge associated with industrial activity in a manner to cover a wide variety of facilities. The USEPA has implemented NPDES regulations for storm water discharges from transportation facilities, which specifically identify airport de/anti-icing operations. These regulations will require proper management of wastes generated by such operations. Regulators at the State and local levels have also begun to establish more stringent limits for de/anti-icing chemicals in storm water discharges. At this writing, the USEPA informed the FAA in February 2008 that they expect to release a Notice of Proposed Rule Making (NPRM) in November 2008 with a 120 day comment period. The objective of the Effluent Limitations Guidance for deicing discharges is to set minimum standards for managing discharges of deicing runoff that will be incorporated into NPDES permits held by all airports covered by the regulations. The USEPA plans to publish the proposed rule in 2008 and take final action in September 2009. A separate branch of the USEPA is charged with regulating storm water under the NPDES program. Most airports have an NPDES permit that regulates the discharge of storm water collected at the airport.

1.5.2. Planning Team. The regulations for proper management of airport-generated industrial waste will no doubt become more restrictive with time. In addition, other chemicals currently contained in water discharges from the airport may become subject to future regulation. Thus, it is recommended that airport operators confer with the airlines, tenants, and other involved parties to plan a comprehensive program for effective management of all current and expected future waste. Besides addressing the airport’s site-specific and operational needs, this approach produces a unified program benefiting all parties. It is also recommended, in the planning of airport expansion or the designing of new airports, that airside drainage systems have the capability, when required, of channeling certain portions of or all airside runoff to specific locations for proper management.

1.6. DEVELOPING A STORM WATER POLLUTION PREVENTION PLAN. The process for developing a SWPPP is outlined in Chapter 12. The SWPPP identifies all potential pollutant sources and include descriptions of control measures to eliminate or minimize contamination of storm water. The

application of Best Management Practices (BMP) is an essential element of the SWPPP. The USEPA is expected to revise published BMPs for airport storm water in 2009.

Intentionally left blank.

POTW Operation

CHAPTER 2. HAZARDS AND NUISANCES OF AIRPORT INDUSTRIAL WASTE

2.1. CHARACTERISTICS. The Federal regulations governing hazardous substances define a hazardous substance by the following characteristics: ignitability, corrosivity, reactivity, and toxicity. If a substance meets the thresholds outlined in RCRA regulations (40 Code of Federal Regulations (CFR) §261) then the substance may interfere with the POTW operation, or contaminate groundwater or contaminate surface waters.

2.1.1. Ignitability. Highly flammable liquids and vapors contained in some airport industrial wastes are fire and explosion hazards, particularly when discharged freely to sewers, natural bodies of water, or the ground. Vapors from volatile solvents, fuels, and oils may travel considerable distances in sewers and certain soils and form explosive concentrates in low, enclosed places. Wastes with a high solids content may cause deposits that form explosive gas during decomposition.

2.1.2. Corrosivity. Corrosive wastes can dissolve metals and other materials or burn human skin. Wastes generated during rust removal and acid or alkaline cleaning, as well as spent lead acid, lithium, and nickel-cadmium batteries, are corrosive wastes.

2.1.3. Reactivity. Wastes which are reactive are unstable or undergo rapid or violent chemical reaction with water or other materials. Wastes generated from cyanide plating operations and from processes involving oxidizers, such as bleaches, are reactive wastes.

2.1.4. Toxicity. Certain airport industrial wastes are toxic to human beings, livestock, and aquatic life, either by direct contact or through the contamination of water supplies. Pollutants contained in metal finishing wastes, such as cyanide and chromium, and certain organic compounds, such as degreasing solvents, are highly toxic at low concentrations in water. Mixed solutions of metal wastes can be much more toxic than simple solutions of corresponding or greater concentration. The formation of sludge deposits in streams by certain airport industrial wastes can create a potential health hazard to prospective users of the stream and restrict or prohibit its use for recreational or agricultural purposes.

2.2. INTERFERENCE WITH WATERWAY PURIFICATION OR POTW OPERATION. The discharge of airport industrial wastes to surface waters or to a POTW may have numerous adverse consequences. The airport operator should understand the potential for and establish measures and procedures to address situations where there would be adverse consequences due to the discharge of airport industrial wastes to such waters or facilities. This may include reviewing spill prevention and countermeasure plans and notifying facility authorities of potential problems.

2.2.1. Waterway Self-purification. The self-purification of waterways depends largely on a sufficient supply of oxygen to support the life and activity of fish and other aquatic organisms. Oils and greases form mats and slicks that hinder re-oxygenation of streams. Wastes with heavy organic loads will result in the consumption of dissolved oxygen when they biodegrade, and may form sludge deposits that could interfere with stream self-purification processes.

2.2.2. POTW Operation. Increases in the organic loading to a POTW may cause the total loading to exceed its headwork loading capacity; thereby, decreasing the plant’s efficiency or violating the NPDES discharge permit. Suspended solids increase the demand on POTW sludge handling equipment and may hinder POTW sludge digestion. Emulsified oil and grease may adversely impact receiving waters. Toxic metals and toxic organic compounds may interfere with biological activity and may complicate sludge disposal. Acids and alkalies may corrode pipes, pumps, and treatment units and may interfere with settling and biological activity. Flammable materials may cause fires and may lead to explosions.

CONTAMINATION OF GROUND WATER

Noxious gases present a direct danger to worker’s health and safety, while detergents may cause foaming in aeration basins. The use of aircraft deicing fluids both ethylene glycol (EG) and propylene glycol (PG) - based fluids may not be accepted by a POTW due to the high organic load impact. Wastes with heavy organic loads will result in the consumption of dissolved oxygen when they biodegrade and may form sludge deposits that could interfere with stream self-purification processes. These consequences also need to be addressed for onsite airport wastewater treatment plants.

2.3. CONTAMINATION OF GROUND WATER. Disposal of airport industrial wastes by land application may be constrained where there is the potential for ground water contamination. Future stringent groundwater regulations may have an impact on airport deicing operations and industrial wastes. These practices are generally unacceptable in areas where affected ground water is used as a source of drinking water.

The toxicity of chromium salts

CHAPTER 3. TYPES OF AIRPORT INDUSTRIAL WASTE

3.1. CLASSIFICATION. Proper classification of airport-generated industrial waste will assist the airport operator in implementing an effective airport waste management program. Once categorized, design alternatives for TSD can be planned in compliance with Federal, State, and local regulations. Airport industrial wastes are classified according to the pollutants they contain or the characteristics they exhibit. The classification includes industrial wastewaters, hazardous wastes and non-hazardous wastes.

3.1.1. Industrial Wastewaters. Industrial wastewaters are generally characterized in terms of conventional pollutants and priority pollutants. Conventional pollutants include oil and grease, total suspended solids (TSS), pH, and biochemical oxygen demand (BOD5). The priority pollutant list is located in Appendix B.

3.1.2. Hazardous Wastes. A waste is considered to be hazardous if it appears on any one of the four lists of hazardous wastes contained in the most recent RCRA regulations (40 CFR §261), or if it has one or more of four characteristics: ignitability, corrosivity, reactivity, and toxicity. Toxicity is currently determined by the Toxicity Characteristic Leaching Procedure (TCLP). Specific testing protocols contained in RCRA regulations (40 CFR §261, Subpart C) are used to determine if an airport’s waste has any of these procedurally defined characteristics. The primary responsibility for determining if a waste exhibits a hazardous characteristic lies with the waste generator.

3.1.3. Non-Hazardous Wastes. Should a material be determined not to be a hazardous waste, then the material should be disposed of in a responsible, reasonable manner for disposal. Such items include oily rags or a sludge that may be packaged for disposal in plastic bags or shipped to be recycled.

3.2. CYANIDES. Cyanides may be present in wastes generated during metal plating, steel hardening, rust prevention, and stain removal operations. The total cyanide concentration specified in ambient water quality criteria established by the USEPA to protect human health is 0.2 parts per million (ppm). Chapter 10 contains alternatives for management of wastes containing cyanides.

3.3. CHROMIUM COMPOUNDS AND TOXIC METALS. Chromium compounds may be present in wastes generated during chromium plating, bright dipping, copper stripping, and anodizing operations. Other toxic metals, such as copper, lead, and zinc, may be generated during metal plating operations. Chapters 9 and 10 contain alternatives for management of wastes containing chromium compounds and other toxic metals.

3.3.1. Implications for POTWs. Wastes containing these compounds above certain concentrations may be toxic to microorganisms utilized in biological treatment. Hexavalent chromium compounds generated by plating and anodizing operations are toxic to aerobic microorganisms utilized in the biological degradation of sewage. Chromium in the trivalent form has also been found to be detrimental to sludge digestion during waste treatment.

3.3.2. The toxicity of chromium salts, both trivalent and hexavalent, varies widely with the pH (acidity and alkalinity), temperature, and hardness of the receiving stream. The total chromium concentration specified in the ambient water quality criteria established by the USEPA to protect human health is 0.05 parts per million (ppm). The National Primary Drinking Water Standards for metals established by the USEPA limit total chromium to 0.10 ppm, cadmium to 0.005 ppm, and lead to 0.015 ppm. National Secondary Drinking Water Standards limit copper to 1 ppm and zinc to 5 ppm.

DE/ANTI-ICING CHEMICAL WASTES

3.4. ACIDS AND ALKALIES. Acidic and alkaline wastes, generated during pickling and cleaning operations, can corrode metal and concrete sewer pipes. Acidic wastes interfere with sludge digestion and biological activity and are toxic to fish. The pH of the airport industrial wastes that are carried through sanitary sewers should be between 6.0 and 9.0. Where both acidic and alkaline wastes are involved, neutralization by mixing of the two may be sufficient to achieve a pH in this range. Preliminary investigation of the compatibility of wastes should be conducted prior to mixing. Chapters 5 and 6 contain alternatives for waste management.

3.5. ORGANIC SOLVENTS AND PHENOLS. These wastes, generated during paint application and removal and the cleaning of aircraft and ground vehicles, can create explosion and toxicity hazards, interfere with sewage treatment, and pollute potable water. Solvents also interfere with bacterial activity in sludge digestion. Solvents and phenols, in particular, produce objectionable tastes and odors in water supplies. The concentration of phenol specified in the ambient water quality criteria for toxicity protection of human health is 3.5 ppm. The concentrations of several common industrial solvents, specified in ambient water quality criteria for carcinogenicity protection of human health, are 0.00019 ppm for methylene chloride, 0.00094 ppm for 1,2-dichloroethane, and 0.0027 ppm for trichloroethylene. Chapter 10 contains design and treatment options for organic compounds. Chapters 9 and 10 contain alternatives for waste management.

3.6. OIL, GREASE, AND/OR DETERGENTS. Precautionary measures should be taken in the design of waste treatment facilities or disposal strategies when wastes contain oil, grease, and/or detergents. These wastes are generated during cleaning of aircraft and ground vehicles and in vehicle maintenance shop operations. Segregation of wastes containing oil and grease helps to avoid coating carrier systems and increasing the BOD5. Oil and grease coatings will also interfere with the efficiency of the precipitants used for coagulation and flocculation of industrial wastes. The mixing of dirt with cleaning wastes increases emulsions and clogs small openings in treatment units unless screened out. The pH of detergent wastes, usually ranging from 9.0 to 10.8, should be lowered by treatment. Detergents may cause partial sludge flotation through release of carbon dioxide. Chapters 9 and 10 contain alternatives for waste management.

3.7. BATTERIES. Spent lead acid, lithium, and nickel-cadmium batteries are generated from routine ground vehicle maintenance. The acidity in high levels in batteries may have adverse impacts on ground water if the batteries are disposed of improperly. Unless recycled, spent batteries are hazardous wastes if they exhibit any of the characteristics noted in Chapter 2. Chapter 6 contains guidelines on hazardous waste management.

3.8. DE/ANTI-ICING CHEMICAL WASTES. For most airports, aircraft de/anti-icing operations generate more waste than pavement de/anti-icing activities. A major problem facing airport operators is the BOD5 and COD loading from de/anti-icing wastes to receiving waters and wastewater treatment plants to ensure compliance with applicable permits and regulations. Airports should take appropriate actions to meet the Federal Deicing regulations expected in December 2009. Chapter 8 contains alternatives for waste management.

ANALYSIS

CHAPTER 4. SURVEYS FOR AIRPORT INDUSTRIAL WASTE

4.1. OBJECTIVES OF A WASTE SURVEY. The general objective of a waste survey is to determine the sources, characteristics, and volumes of wastes that are generated. The specific aim is to assist the airport operator in establishing a sound basis for the management of these wastes, including waste minimization, recycling, or elimination by process modification.

4.2. REQUIREMENTS OF WASTE SURVEY. Requirements of any waste survey planning include familiarity with the airport industrial processes used, operating schedules, sources of individual wastes, and, if one exists, the airport’s industrial sewer system and treatment plant. In order for the survey results to be of maximum value to the airport operator, it is necessary to obtain data for a period of time which is sufficient in length to ensure that all waste-producing operations are surveyed.

4.3. FLOW MEASUREMENT. For continuously flowing wastewater streams, the flow rates of both individual and combined streams should be measured at representative points and expressed in standard units such as gallons per minute (gpm), gallons per hour (gph), or gallons per day (gpd). The method used by the airport operator to determine the flow rate will depend upon the magnitude of flow. Common metering devices include weirs, nozzles, flumes, and flow meters. For wastes that are generated on an intermittent basis, such as spent process baths, certain hazardous wastes, and deicing runoff generation rates can be determined from the disposal volumes and dates.

4.4. SAMPLING. Accurate sampling necessary for correct analysis of airport industrial wastes can be difficult because wastes are seldom homogeneous, e.g., their composition may vary widely over a period of minutes. Flow proportional samples are recommended where applicable. All samples collected should be preserved in the proper manner according to the latest Standard Methods for the Examination of Water and Wastewater and all Chain of Custody Sheets should be accurately and thoroughly completed by the sampler. Additionally, wastes frequently contain material in suspension as well as in solution.

4.4.1. Industrial Wastewater. For industrial wastewaters, grab or composite samples should be taken and properly preserved before analysis. The sampling operation should be as frequent as situation specific requirements dictate.

4.4.2. Hazardous Waste. For hazardous wastes, sampling to determine waste characteristics should initially be frequent (e.g., collection of several samples of wastes each time the waste is generated) and should subsequently be performed periodically (e.g., monthly, annually, or biannually) to confirm that waste characteristics have not changed.

4.4.3. Non-Hazardous Waste. Generally, once a waste is determined not to be a hazardous waste then responsible disposal practices should be used. These practices include bagging the waste for trash receptacles, or shipment of the waste to laundry facilities or recycling facilities for reuse.

4.5. ANALYSIS.

4.5.1. Industrial Wastewater. Wastewater constituents which are required to be sampled and analyzed are dictated by discharge permit limits that are applicable to the waste streams. Parameters which are typically monitored include BOD5, Chemical Oxygen Demand (COD), dissolved oxygen (DO), pH, total solids (suspended and dissolved), effluent temperature, color, turbidity, and oil and grease. Where there is reason to be concerned about toxicity testing may be required for specific toxic pollutants such as those listed in Appendix B. The recommended reference for analytical procedures for wastewaters is the latest edition of Standard Methods for the Examination of Water and Wastewater.

STORMWATER POLLUTION PREVENTION DEVELOPMENT ASSESSMENT

4.5.2. Hazardous Waste. Methods for analysis of hazardous waste characteristics are specified in 40 CFR § 261 Subpart C of the RCRA regulations.

4.5.3. Non-Hazardous Waste. If waste is determined not to meet the criteria for hazardous waste, then the waste should be disposed of in a responsible manner, typically through common waste/refuse management disposal practices.

4.6. STORMWATER POLLUTION PREVENTION DEVELOPMENT ASSESSMENT. The SWPPP must identify, through assessment, all potential pollutant sources. A map of the industrial facility is essential showing the contributing areas to each drain and ultimately each storm water discharge point. The SWPPP should identify the manufacturing process and the inventory of all materials used and the potential exposure to storm water. The quantity of each material or chemical used should also be quantified. The document Environmental Screening Checklist and Workbook for Airports and Tenant Operations, July 2000 provides an effective tool for the assessment of potential pollutant sources.

RECOVERY AND REUSE.

CHAPTER 5. MANAGEMENT STRATEGIES FOR AIRPORT INDUSTRIAL WASTE

5.1. MANAGEMENT STRATEGIES. Historically, waste management at most industrial facilities has used end-of-pipe systems for the treatment of wastewaters and other wastes. Costs of waste disposal, stringent regulations for hazardous waste management, and regulations that prohibit land disposal of certain wastes have caused attention to be focused on management strategies that reduce the total volume, toxicity, and/or mobility of toxic wastes. Source reduction, recovery, and reuse can significantly decrease or eliminate airport waste as well as an airport’s operational costs for treatment and/or disposal. To determine the potential savings of these operational costs, a study should be made of industrial and hazardous waste management at the airport. This AC highly promotes the use of an Environmental Management system (EMS). A complete EMS would monitor inventory, pollutant streams, how to maximize the potential to reduce pollutant loading/toxicity and how to reuse/recycle to the maximum extent feasible and to keep all requirements on a regular cycle for evaluation and permit re authorization. The value of the EMS is not just in compliance but in the process that formalizes asking the questions regarding impacts to the environment and how to routinely plan for reduction.

5.2. SOURCE REDUCTION. A waste survey (see Chapter 4) is the first step an airport operator has in identifying source reduction opportunities. After determining the volume and composition of waste streams, information should be compiled on how and where the waste is generated, process efficiencies, disposal costs, and unaccountable material losses. Keeping the number of solvents to a minimum makes recycling easier and reduces hazardous waste management costs. Conduct all liquid cleaning at a centralized station to ensure solvents and residues stay in one area. Store drip pans for direct solvents in a solvent sink or tank for reuse. Use non-hazardous cleaners when possible. Use as little water as possible to clean spills, leaks, and drips. Reuse water if possible and prevent any process water from leaking into non-contact cooling water or storm water. Operate machinery at correct temperatures and flow levels and consider using automatic control and lock-out valves. Install automatic flow controls or multiple rinse tanks in a counter-current series system and use drag-out recovery techniques. Use sprays or mist to rinse off excess process solution and agitate the rinse bath to increase its efficiency.

Raw material substitution can reduce or eliminate the use of certain materials that are difficult or costly to treat or dispose of. Maintenance associated with materials’ management should be designed to minimize the amounts of materials used and the wastes generated by industrial processes. Installation of more efficient equipment and improved process control, such as automated de/anti-icing blending equipment or involving employees, can reduce waste generation. Reduction of certain types of wastes can be achieved by installing equipment that performs the same function, for example, the use of an infra-red deicing facility in lieu of conventional deicing chemical application. Use detergent-based or water-based cleaning systems instead of organic solvent degreasers. Steam clean or pressure wash parts instead of using solvents.

5.3. RECOVERY AND REUSE. Recycling of materials that might otherwise be discharged as wastes can reduce an airport’s waste treatment and disposal costs as well as the expense for raw materials. Examples of waste recovery and reuse that are particularly applicable to activities at airports are the recovery of paint solvents by distillation, the recovery of electroplating chemicals using dragout recovery tanks, and de/anti-icing chemicals for other non-airside uses, or for airside use, after retesting and reapproval. Sludges that meet the USEPA Biosolids criteria may be considered for beneficial use for uses such as:

• Farm land

• Forest land

TREATMENT

• Public works projects

• Landscaping

• Land reclamation projects.

A typical recovery process to reclaim the glycol in runoff from aircraft deicing operations includes pretreatment to remove dirt and debris, nano-filtration to remove the high molecular weight additives and distillation to increase the concentration of glycol in solution. The performance based standards for aircraft deicing fluid indirectly limit the onsite reuse of glycols because all recovered product must undergo performance based recertification. The reuse of any glycol for aircraft or runway application must be recertified in accordance with the appropriate SAE AMS specifications.

5.4. TREATMENT. Once opportunities for source reduction and recovery and reuse are exhausted, waste treatment may be necessary to reduce the volume, toxicity, or mobility of waste prior to discharge or disposal. Some industrial wastewater treatment technologies available to the airport operator are discussed in detail in Chapters 9 and 10. Chapter 6 offers airport operators management guidelines for hazardous waste.

GENERATOR IDENTIFICATION NUMBER

CHAPTER 6. MANAGEMENT OF HAZARDOUS AND NON-HAZARDOUS WASTE

6.1. HAZARDOUS WASTES. The requirements of the hazardous waste regulations established by the USEPA are presented in 40 CFR §261 through 270. Wastes that are hazardous and regulated under RCRA are classified as either listed or characteristic wastes.

6.1.1. Listed Wastes. Listed wastes are considered to be hazardous regardless of the concentrations of hazardous chemicals contained in the waste. Listed hazardous wastes consist of wastes from nonspecific sources (F codes, 40 CFR §261.31), from specific sources (K codes, 40 CFR §261.32), and from commercial products (U and P codes, 40 CFR §261.33). The P code wastes are considered acutely hazardous and are subject to further restrictions concerning empty container storage and usage and allowable weight limits for generation and storage.

6.1.2. Characteristic Wastes. If a waste is not listed, the generator, in this case an airport facility operated by the airport itself or a lessee, should determine if a waste exhibits any of the characteristics of a hazardous waste: ignitability, corrosivity, reactivity, and toxicity.

6.2. GENERATOR STATUS. According to the Hazardous and Solid Waste Amendments (HSWA), generators are organized into three tiers based on the total quantity of non-acutely hazardous waste generated in any calendar month.

6.2.1. Conditionally Exempt Small Quantity Generators (CESQG). CESQGs generate less than 100 kilograms (kgs) of hazardous waste and no more than 1 kg of acutely hazardous waste in any calendar month. Most airport facilities fall into this category the majority of the time.

6.2.2. Small Quantity Generators (SQG). SQGs generate between 100 and 1000 kg of hazardous waste and no more than 1 kg of acutely hazardous waste in any calendar month. Some airport facilities fall into this category.

6.2.3. Large Quantity Generators (LQG). LQGs generate 1000 kg or more of hazardous waste or more than 1 kg of acutely hazardous waste in any calendar month. Airport facilities that operate aircraft maintenance and repair shops and engine test cell operations may meet this criterion.

6.2.4. Monthly Variation in Status. The status of an airport facility can change on a monthly basis if the total quantity of waste generated changes. If the generator status changes, the airport facility is subject to all of the applicable hazardous waste regulations pertaining to the new generator status. Airport facilities that anticipate process changes or that experience fluctuations in waste generation, storage, or accumulation need to be aware of their new responsibilities if their generator status changes.

6.3. GENERATOR IDENTIFICATION NUMBER. Certain hazardous waste generators must have the 12 digit USEPA Identification Number to perform the requirements of 40 CFR Part 262.12. Identification numbers are required for persons that generate or manage hazardous waste, including small and large quantity generators, transporters, and treatment, storage, and disposal facilities. A USEPA identification number for each site that generates hazardous waste is necessary. Once the proper authority has been contacted, an USEPA Form 8700-12, Notification of Regulated Waste Activity, is sent. A USEPA identification number is issued for each location. Only SQG and LQG airport facilities are required to obtain a USEPA Identification Number for the transportation of hazardous waste. However, many hazardous waste transporters will not handle waste from an airport facility that does not have an Identification Number, regardless of their generator status. Also, because the status of a generator can

ACCUMULATION UNITS

change based upon monthly hazardous waste generation, it is advisable for CESQG airport facilities to obtain a USEPA Identification Number.

6.4. ACCUMULATION TIME. Time and quantity limits are set for the accumulation and storage of hazardous wastes to minimize the amount of waste routinely accumulated onsite. The time and quantity limits have been set, however, so that facilities such as airports may accumulate enough hazardous waste to ship it economically offsite for treatment or disposal.

6.4.1. Accumulation by CESQG Airport Facilities. There is no time limit applicable to the accumulation of hazardous waste by a CESQG. If a CESQG airport facility accumulates 1000 kg or more of hazardous waste onsite; however, the generator loses the CESQG exclusion. All of the accumulated waste is subject to full regulation under 40 CFR §262.34(d) and must be sent to a designated facility within 180 days (270 days for transport over 200 miles).

6.4.2. Accumulation by SQG Airport Facilities. An SQG airport facility may accumulate hazardous waste onsite without a permit or interim status for up to 180 days (or 270 days if the waste must be transported over 200 miles) provided that the following conditions are met: 1) the generator does not accumulate 6000 kg or more of hazardous waste; 2) the waste is only accumulated in either containers or tanks; and 3) the generator complies with the requirements for personnel training, emergency procedures, preparedness and prevention, and the technical standards for accumulation units according to 40 CFR §262.34(d).

6.4.3. Accumulation by LQG Airport Facilities. An LQG airport facility may accumulate any quantity of waste onsite for up to 90 days without a permit or interim status provided the following conditions from 40 CFR §262.34 are met: 1) storage occurs only in tanks or containers (no impoundments); 2) tanks or containers comply with 40 CFR §265, Subpart I, Standards for Containers, and Subpart J, Standards for Tanks; 3) the generator does not accept shipments of hazardous waste generated from offsite sources; 4) waste is sent to a designated facility within 90 days unless the waste is treated and rendered non-hazardous within the 90 days; and 5) the generator complies with the requirements for Preparedness and Prevention and Contingency Plan and Emergency Procedures of 40 CFR §265.

6.4.4. Exceeding Time or Quantity Limits. If SQG or LQG airport facilities exceed the time or quantity limits noted above, then they are considered to be storage facilities and must obtain a storage permit (as discussed below) and meet all of the RCRA storage requirements according to 40 CFR §264, §265, and §270.

6.5. ACCUMULATION UNITS. Airport facilities are required to designate areas within its facilities where hazardous wastes are stored prior to disposal. Containers in this area should be clearly marked. The requirements for containers in which hazardous wastes are accumulated are as follows:

6.5.1. Accumulation Requirements for CESQG Airport Facilities. CESQG airport facilities are not subject to storage or accumulation requirements unless they change generator status due to the amount of waste accumulated onsite. Nevertheless, following the rules for LQGs and SQGs should minimize potential risks to both human health and the environment.

6.5.2. Accumulation Requirements for SQG Airport Facilities. SQG airport facilities accumulating hazardous waste in containers must comply with Subpart I of 40 CFR §265, except for §265.176, which requires ignitable (§261.21) and reactive (§261.23) wastes to be placed at least 50 feet (15.2 m) inside the facility’s property line.

ONSITE TREATMENT AND DISPOSAL

6.5.3. Accumulation Requirements for LQG Airport Facilities. LQG, CESQG and SQG airport facilities accumulating hazardous wastes in containers must comply with Subpart I of 40 CFR §265. The date when accumulation begins and the words "HAZARDOUS WASTE" must be clearly labeled on each accumulation unit. Tanks in which hazardous wastes are accumulated must be in compliance with the provisions of Subpart J of 40 CFR §265, except §265.197(c) and §265.200, including: 1) a one-time assessment of the tank system, including integrity test results; 2) installation standards for new tank systems; 3) design standards, including an assessment of corrosion potential; 4) secondary containment phase in provisions; 5) periodic leak testing if the tank system does not have secondary containment; 6) closure; and 7) response requirements regarding leaks, including reporting to the USEPA Regional Administrator the extent of any release and requirements for repairing or replacing leaking tanks.

6.5.4. Tank Accumulation Requirements for LQG and SQG Airport Facilities.

6.5.4.1. Tank Systems. LQG and SQG airport facilities accumulating hazardous waste in a tank must comply with the following requirements pertaining to tank systems: 1) treatment must not generate any extreme heat, explosions, fire, fumes, mists, dusts, or gases, damage the structural integrity of the tank, or threaten human health or the environment in any way; 2) hazardous wastes or reagents that may cause corrosion, erosion, or structural failure must not be placed in a tank; 3) at least 2 feet (0.6M) of freeboard must be maintained in an uncovered tank unless sufficient overfill containment capacity is supplied; 4) the containment system must have the capacity to contain 10% of the volume of containers (if they are, grouped together) or of the largest (or sole) container, whichever is greatest; 5) continuously fed tanks must have a waste-feed cutoff or bypass system; and 6) ignitable, reactive, or incompatible wastes must not be placed into a tank unless these wastes are first rendered non-ignitable, non-reactive, or nonflammable.

6.5.4.2. Inspection Timetables. The waste-feed cutoff and bypass systems, monitoring equipment data, and waste level must be inspected at least once each operating day. The construction materials and the surrounding area of the tank system must be inspected for visible signs of erosion or leakage at least weekly. At closure of the generating facility, all hazardous wastes must be removed from the tanks, containment systems, and discharge control systems. Owners or operators of 90-day accumulation tanks are not required to prepare closure or post-closure plans, contingent closure or post-closure plans, maintain financial responsibility, or conduct waste analysis and trial tests.

6.5.5. Satellite Accumulation. A generator may accumulate a total of 55 gallons (208 L) of hazardous waste or 1 quart (0.97 L) of acutely hazardous waste at or near any initial generation point. As soon as the 55-gallon (208 L) or l-quart (0.97 L) limit is attained, the generator has up to three days to move that container to the regular storage area. As soon as the container is at the regular storage area, the applicable time limit starts. Satellite accumulation containers must be marked with the words “HAZARDOUS WASTE” or with other words that identify the contents of the containers (40 CFR §262.34(c)(1) and 40 CFR §261.33).

6.6. ONSITE TREATMENT AND DISPOSAL. Treatment in a tank or container without a permit or interim status is permissible provided that the airport facility maintains compliance with 40 CFR §262.34. Treatment occurs within the storage time limit for each type of generator status. An airport facility may not dispose of hazardous waste onsite unless a disposal permit has been obtained. Any airport facility desiring to store, treat, or dispose of hazardous waste in any manner not consistent with allowable methods previously described needs a permit as described in 40 CFR §270. Obtaining a permit to store, treat, or dispose of hazardous wastes onsite can be both costly and time consuming. The operator of such an airport facility can obtain a permit by: 1) notifying the USEPA or the appropriate State agency of hazardous waste activity; 2) completing Part A of the permit application; 3) complying with the interim

PERSONNEL TRAINING, PREPAREDNESS AND PREVENTION, AND CONTINGENCY PLANS…

status standards described in 40 CFR §265; 4) completing Part B of the permit application; and 5) complying with the standards described in 40 CFR §264 and §266.

6.7. MANIFESTS.

6.7.1. LQG Airport Facility Requirements. An LQG airport facility transporting hazardous waste offsite or offering it for transportation must use the Uniform Hazardous Waste Manifest (UHWM).

6.7.1.1. General Procedure. The manifest must accompany the waste wherever it travels. Each individual involved in a shipment must sign and keep one copy. When the waste reaches its final destination, the owner or operator of the designated and permitted TSD facility signs the manifest and returns a copy to the airport facility operator to confirm receipt. A designated TSD facility must have interim status or a permit. The designated TSD facility signing the manifest accepts responsibility for that shipment and cannot ship the waste back to the airport facility or any other facility unless that facility is also classified as a designated facility. Although a facility may accept responsibility for a shipment, the airport facility operator retains liability under 40 CFR §107 of the Superfund Amendments and Reauthorization Act (SARA).

6.7.1.2. Followup. Each person involved in the movement, storage, or receipt of hazardous waste requiring a manifest must retain a copy of that manifest for at least three years. If an airport facility operator does not receive a copy of the signed manifest from the designated TSD facility within 35 days after the initial transporter accepted the waste, the airport facility operator must contact the designated facility to determine the status of the waste. If the airport facility operator has not received a signed manifest within 45 days, an exception report, which consists of a copy of the original manifest and a letter explaining the efforts taken to locate the waste and the results of those efforts, must be filed with USEPA.

6.7.2. SQG Airport Facility Requirements. An SQG airport facility must use the Uniform Hazardous Waste Manifest and retain copies of manifests for at least three years.

6.7.3. CESQG Airport Facility Requirements. A CESQG airport facility is not legally required to utilize a manifest for hazardous waste. However, many transporters will not handle waste from such facilities. Since airport facilities can change status based upon monthly changes in hazardous waste generation, it is advisable to recommend CESQG airport facilities to utilize manifests and retain copies.

6.7.4. Designating Storage, Treatment, or Disposal Facilities. Any type of storage, treatment, or disposal facility that an airport facility designates to receive hazardous waste must be either: 1) permitted or have interim status under §270 of RCRA; 2) authorized to manage hazardous waste by a State with an authorized program under §271 of RCRA; 3) permitted, licensed, or registered by a State to manage municipal or industrial hazardous waste; 4) a permitted facility that beneficially uses, reuses, or legitimately recycles or reclaims the hazardous waste; or 5) a permitted facility that treats the waste prior to beneficial use or reuse or conducts legitimate recycling or reclamation.

6.8. PERSONNEL TRAINING, PREPAREDNESS AND PREVENTION, AND CONTINGENCY PLANS AND EMERGENCY PROCEDURES. As specified in 40 CFR §262.34, a generator of hazardous waste is required to comply with the requirements of 40 CFR §265.16 (personnel training) and of Subparts C (preparedness and prevention) and D (contingency plan and emergency procedures) of 40 CFR §265.

6.8.1. Personnel Training for LQG Airport Facilities. LQG airport facilities must establish a training program for appropriate facility personnel designed to reduce the potential for errors that might threaten human health or the environment. This program must also include training to ensure facility compliance

EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW

with all applicable regulations. Both initial training and annual updates are required. Either on-the-job or formal classroom instruction is allowable; however, the content, schedule, and techniques used for on-thejob training must be detailed in the training records maintained at the facility.

6.8.2. Personnel Training for SQG Airport Facilities. SQG airport facilities must ensure that all involved employees are thoroughly familiar with proper waste handling and emergency procedures relevant to their responsibilities during normal facility operations and emergencies via generatorsponsored instruction. The training requirement is minimal compared to the more comprehensive instruction required for LQG airport facilities.

6.8.3. Personnel Training for CESQG Airport Facilities. CESQG airport facilities are not legally required to provide personnel training; however, it may be advisable to provide, at a minimum, the type of training required for SQGs, particularly given that generator status could change.

6.8.4. Preparedness and Prevention. Facilities that generate waste onsite must be in compliance with 40 CFR 265.1 (c) (7).

6.8.5. Contingency Plan and Emergency Procedures. Both LQG and SQG airport facilities must have a contingency plan, as outlined in Subpart D of 40 CFR §265, that is designed to minimize hazards in the case of a sudden or non-sudden release, fire, explosion, or similar emergency.

6.8.5.1. Plan Requirements. Such a plan must contain a description of actions that will be undertaken by facility personnel, a detailed list and location of emergency equipment, and evacuation procedures. Airport facility operators who have previously prepared a Spill Prevention, Control, and Countermeasures (SPCC) Plan in accordance with either 40 CFR §112 or §300, or some other emergency or contingency plan, need only to amend that plan to incorporate hazardous waste management provisions.

6.8.5.2. Personnel Requirements. There must be at least one employee either on the premises or on call (i.e., available to respond to an emergency at the facility within a short time) at all times with the responsibility of coordinating all emergency response measures (the emergency coordinator). The emergency coordinator, in responding to any emergencies that may arise, should institute the following emergency procedures, if appropriate: 1) contact the fire department and/or attempt to extinguish any fire; 2) contain any flow and commence cleanup wherever possible; and 3) notify the National Response Center of any fire, explosion, or release that meets a Superfund reportable quantity (40 CFR §302) or a release that threatens human health or the environment. The airport facility must post the name and telephone number of the designated emergency coordinator, the telephone numbers of the fire department and appropriate emergency response organizations, and the locations of fire extinguishers, spill control equipment, and fire alarms next to all appropriate facility telephones.

6.9. EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW. In the fall of 1986, Congress passed the Emergency Planning and Community Right-To-Know Act (EPCRA). This law, which is Title III of the SARA, directs States, communities, and industry (e.g., airport facilities) to work together in order to plan for chemical accidents, develop inventories of hazardous substances, track toxic chemical releases, and provide public access to information relating to hazardous substances. Airport facilities that handle or use any of a list of extremely hazardous chemicals over certain quantities must notify public agencies that they are covered by the emergency planning provisions of Title III and must appoint representatives to provide detailed information to State commissions and local committees that will be used to prepare emergency preparedness plans. Both airport facilities and aircraft are treated as facilities under Section 40 CFR §304 (42 U.S.C. 11001). Only for the purpose of emergency notification, owners or operators of facilities must also notify the State’s emergency response commission immediately

after an accidental release of an extremely hazardous substance that is over the reportable quantity established for that substance, as well as follow-up written reports for the release. Title III also requires facilities that make, store, or use certain chemicals to file reports with the State commission and local committees if the chemicals are present above certain thresholds. Facilities that are required to maintain material safety data sheets (MSDSs) under the Occupational Safety and Health Administration (OSHA) Hazard Communication (HC) Standard must submit the MSDSs or a list of MSDSs to State and local authorities. Annual chemical inventory forms must also be supplied to State and local authorities.

COLLECTION SYSTEMS

CHAPTER 7. AIRPORT INDUSTRIAL WASTES CONVEYANCE AND COLLECTION

7.1. CONVEYANCE SYSTEMS. Airport industrial wastes containing appreciable amounts of certain materials, such as heavy metals, solvents, sludges, oils, greases, acids, or alkalies, are typically segregated and treated prior to discharge to sanitary sewers or receiving waters. Several types of collection systems are available to airport operators.

7.1.1. Closed. Closed systems are commonly used for wastes and sanitary sewage. Separate conveyance systems are required for sanitary wastes and airport industrial wastes that require pretreatment.

7.1.2. Special. Special provisions, such as the use of holding tanks or ponds, need to be made for some incompatible wastes which cannot be discharged to sewers without danger of fire, explosion, or damage to the materials used to construct the sewer.

7.2. SEWER MATERIALS. In most cases, the materials used to construct sewers to convey airport industrial wastes are the same as those used for sanitary sewers. These materials include metal, plastic, and concrete. Acid wastes are particularly corrosive to these materials. Cooling of wastes with temperatures above 180°F (82°C) prior to discharge to the sewer helps to prevent possible damage to sewer joints. For the selection of piping and pumps, consideration during design should be given to the corrosive and other damaging effects of many wastes on concrete and metal. In many applications, plastic pipe is less vulnerable to attack and is often used in place of metal pipe.

7.3. COLLECTION SYSTEMS. Concentrated waste materials can be segregated in holding tanks or ponds prior to pretreatment. This is often the case when the quantities involved are large enough to cause operational difficulties if combined with the general waste flow. Materials for which collection systems are often used include: concentrated acids, concentrated alkaline solutions, cleaners, solvents, plating solutions, stripping solutions, cyanide wastes, phenolic compounds, and de/anti-icing chemicals. Wastes are released from the collection systems for treatment at times and rates most favorable to the airport’s or community’s treatment system operation.

Intentionally left blank.

LAGOONS AND RETENTION PONDS

CHAPTER 8. MANAGEMENT OF DE/ANTI-ICING CHEMICAL WASTES

8.1. GENERAL GUIDANCE. The Airport Cooperative Research Program (ACRP) funded by the FAA, developed ARCP Report #11, Managing Runoff from Aircraft and Airfield Deicing and Anti- Icing Operations, in response to a need the airport industry identified for planning guidelines to assist airport and aircraft operators in identifying and selecting best management practices (BMPs) for controlling aircraft and airfield deicing runoff. Aircraft operators are included in this target audience because of their role as key participants and stakeholders in any decisions that may affect aircraft safety or operations. This introductory section presents background on the origins and drivers behind this research project, describes the purpose and objectives of this document, and explains the structure of the planning guidance. Subsequent sections present guidelines for developing integrated deicing runoff management systems (Section 2), guidance for evaluating and selecting individual BMPs (Section 3), and fact sheets describing each of the BMPs (Section 4). ACRP Project Report #11 is available at - http://www.trb.org/news/blurb_browse.asp?id=136.

8.2. AIRCRAFT DEICING FACILITIES. The operation of off-gate aircraft deicing facilities is a proven effective means for managing sprayed aircraft deicing/anti-icing fluids that do not remain on the aircraft. In general, aircraft deicing facilities consist of a two or more deicing pads, a drainage collection system, and a wastewater storage facility. At some airport locations, airport operators employ the use of infra-red technology to reduce the qualities of ADFs sprayed to deice aircraft. It is noted that infra-red is only used during the deicing phase. The anti-icing of any aircraft still requires the spraying of an appropriate aircraft anti-icing fluid. For design of traditional and infra-red facilities, please see AC 150/5300-14, Design of Aircraft Deicing Facilities.

8.3. RUNWAY SURFACE CONDITION MONITORING SYSTEMS One effective mean of preventing unnecessary application of pavement deicing/anti-icing agents is using runway surface condition monitoring systems. These devices measure the change in pavement temperature with some units providing surface condition and atmospheric weather conditions. By enabling airport maintenance staff to monitor continuously runway surface conditions, maintenance staff can predict freezing conditions by tracking changes in pavement temperature and apply new or additional pavement deicers in a timely manner. See AC 150/5200-30 for surface condition sensor specifications.

8.4. LAGOONS AND RETENTION PONDS. Conversion of suitable unused airport land into lagoons or retention ponds permits collection of large volumes of glycol-based fluid waste from pavement surface runoff.

8.4.1. Capacity. The minimum design capacity handles at least the surface runoffs for winter months because microbial activity needed for biodegradation decreases during the winter season, plus incorporate additional capacity for the thawing periods. Required oxygen could be provided by mechanical aeration or photosynthesis, although there would also be a decrease in algal growth during cold weather. Capacity requirements can be reduced by continuous aeration that allows for faster biodegradation and, thus, earlier release of glycol-based fluid waste. Additionally, lagoons of this type could also stabilize and pre-treat glycol-based fluid waste prior to discharge to a wastewater treatment plant.

8.4.2. Configuration. An acceptable configuration for any retention basin is one that is easily defensible from a wildlife standpoint. Square or circular retention basins are not recommended as they are attractive to birds, and waterfowl will seek the safety of a pond’s center to escape harassment activities. Hence, linear retention basins are recommended since they facilitate wildlife harassment and, if

necessary, permit easier covering of the basin. As concentrated glycol is toxic to wildlife, covering may be necessary to prohibit any wildlife use. Fencing is recommended whenever potentially hazardous compounds are stored in open areas.

PHYSICAL UNIT OPERATIONS

CHAPTER 9. TREATMENT TECHNIQUES FOR INDUSTRIAL WASTEWATERS

9.1. GENERAL. Pretreatment is generally necessary to prevent the deleterious effects of acids, alkalies, oils, and greases on treatment units and on microorganisms utilized in biological treatment. The need for pretreatment is very application specific. The techniques used for treatment of industrial wastewaters may involve various physical, chemical, and biological unit operations, tertiary treatment, and other treatment technologies. The operator of any treatment facility should furnish operator manuals and basic employee training in the proper operation of the treatment facility.

9.2. PHYSICAL UNIT OPERATIONS. Techniques used for the physical treatment of industrial wastewaters include equalization, screening, communition, grinder pumps, grit removal, sedimentation, and flotation.

9.2.1. Equalization. Equalization is typically one of the first operations in a treatment system and is used to reduce the temporal variation in wastewater flow or concentration.

9.2.2. Screening. Bar racks (also called bar screens) with relatively wide spacing of 1 to 1.5 inches (2.5 to 3.8 cm) are often used at treatment plants for protecting pumps and treatment units from damage and clogging by large solids, rags, and other debris carried by sewage or wastewater. Revolving drum or disk screens with 1/16-inch to 1/4-inch (1.6 to 6.4 mm) openings may be suited for preliminary treatment of wastes containing coarse solids.

9.2.3. Comminution. Comminutors are devices that are used to cut up solids contained in wastewater. The cut up of solids into a smaller, more uniform size improves downstream operations and processes and eliminates other operational problems. A comminutor may be found at an airport prior to an onsite treatment system.

9.2.4. Grinder Pumps. Grinders or macerators are sometimes provided in piping systems for shredding solids, rags, and other debris to reduce wear on downstream pumps.

9.2.5. Grit Removal. Wastes from maintenance and repair operations are likely to contain considerable amounts of grit as well as dirt and grease. Washing and steam cleaning are major sources of these waste components. Grit is objectionable because it can clog sewers and cause rapid wear on pumps and sludge removal equipment. It is also harmful when treatment systems include sludge digestion because it can accumulate in the digester and clog draw-off piping. Wastes containing an excessive amount of grit should be segregated and subjected to grit removal and treatment by means of a grit chamber prior to discharge to sewer systems, pumping stations, or waste treatment systems. A grit chamber is an enlarged channel or long tank placed at the influent end of the treatment plant. A properly designed cross section will retard the flow velocity just enough to promote the gravitational settling of heavier solids prior to their removal.

9.2.6. Sedimentation. Sedimentation, with or without chemical pretreatment, is used in connection with the treatment of most industrial wastes because it produces a substantial reduction in the suspended solids content. Sedimentation basins similar to those used for sanitary sewage treatment are used for the treatment of industrial wastes. Normally, mechanical sludge and scum removal equipment is utilized during the process.

9.2.7. Flotation. Suspended material, such as oil, grease, and other substances with a specific gravity less than that of water, tends to separate from water by floating. Fine particles and some flocculent material with a specific gravity greater than that of water tend to settle, but at a very slow rate. Flotation

CHEMICAL UNIT OPERATIONS

may be employed to remove these materials and may be accomplished in simple gravity separators or in dissolved air flotation units.

9.2.7.1. Gravity Separators. Gravity oil-water separators are good processors for the treatment of wastewaters generated by activities producing large amounts of oily wastes. The American Petroleum Institute (API) Separator is an example of a gravity separator of proven usefulness for oil removal. It consists of a long, narrow, relatively shallow, baffled basin equipped with a continuous skimming and scraping mechanism. Generally, free-floating dispersed oil, which will coalesce rapidly, is readily separated from industrial wastewater in this type of basin. Emulsified oil that coalesces slowly, however, is not reduced appreciably and needs to be chemically treated to break the emulsion.

9.2.7.2. Dissolved-air Flotation. This method is used to remove oil and grease from airport industrial wastes and involves the production of many small air bubbles within the waste. These bubbles attach themselves to the suspended particles, causing them to float to the surface and be skimmed by mechanical means. The clarified water is removed from the flotation tank through submerged outlets. The efficiency of the process may be improved by the addition of flocculating chemicals, such as alum, activated silica, and polymers.

9.3. CHEMICAL UNIT OPERATIONS. Chemicals are added to industrial wastewaters to achieve neutralization, break up oil and grease emulsions, coagulate suspended or colloidal solids, oxidize cyanides, reduce chromium, and precipitate heavy metals.

9.3.1. Neutralization. Concentrated acidic or alkaline wastes normally require neutralization prior to discharge. When both types of wastes are available, mixing the two is advantageous, since only the excess acid or alkali requires further neutralization. Reactivity of the combined wastes should be evaluated prior to mixing waste streams.

9.3.1.1. Pickling Acids. Acid wastes from metal pickling and finishing operations usually present the greatest problems. The various acids used in the pickling process are sulfuric, nitric, hydrochloric, and phosphoric, with sulfuric acid being the most commonly used. Quick lime and hydrated lime are the alkaline neutralizing agents most commonly used.

9.3.1.2. Treatment Modes. Neutralization may be accomplished by either continuous or batch treatment methods (see figures 9-l and 9-2). Neutralization is carried out by feeding lime slurry to the spent pickle liquor in a tank equipped with an agitator. Lime requirements are obtained from the “acid value” of the pickle liquor and the “alkaline value” of the lime as determined by chemical analysis. The sludge formed in the process is disposed of in a sanitary landfill or as a hazardous waste if its heavy metal content is too high. Hazardous waste management is discussed in Chapter 6.

9.3.2. Breakup of Oil and Grease Emulsions. Emulsions can be broken by acidification, the addition of alum or iron salts, or the use of emulsion-breaking polymers. The disadvantage of adding alum or iron is the large quantities of volume generated. The breaking of emulsions is a complex art and often requires treatability testing prior to developing a final process design.

9.3.3. Coagulation and Flocculation. Coagulation and flocculation are employed to remove suspended or colloidal materials from wastewater. Chemicals commonly used for coagulation include alum, ferric salts, and polymers. Equipment used for coagulation and flocculation often consists of a rapid-mix tank, in which chemicals and wastewater are mixed, and a flocculation basin, in which rotating paddles promote particle aggregation. The flocculated mixture is settled in conventional settling tanks.

MEMBRANE PROCESSES.

LIQUID TO SEWER

MIXING

SETTLING

ALKALINE AGENT

FEED

ACID WASTE

SLUDGE DRAWOFF

Figure 9 - 1. Neutralization (continuous method)

NEUTRALIZED LIQUID TO SEWER

MIXING ALKALINE AGENT FEED ACID WASTE

SLUDGE DRAWOFF

Figure 9 - 2. Neutralization (batch method)

9.3.4. Oxidation, Reduction, and Precipitation. At most airport facilities, oxidation of cyanides, reduction of chromium, and precipitation of heavy metals are treatment processes normally associated with electroplating operations. These technologies are addressed in Chapter 10.

9.4. MEMBRANE PROCESSES. Several membrane processes exist for the treatment of wastewaters which include ultra filtration and reverse osmosis (RO).

9.4.1. Ultra Filtration. Ultra filtration includes a group of membrane filtration in which hydrostatic pressure forces a liquid against a semi-permeable membrane. Suspended solids and solutes of high molecular weight are retained, while water and low molecular weight solutes pass through the membrane. This separation process is used in industry and research for purifying and concentrating macromolecular

BIOLOGICAL UNIT OPERATIONS

(103 - 106 Dalton (Da)) solutions, especially protein solutions. Ultra filtration is not fundamentally different from RO, microfiltration, or nano-filtration, except in terms of the size of the molecules it retains.

9.4.2. Reverse Osmosis (RO). Reverse osmosis is a separation process that uses pressure to force a solvent through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side. More formally, it is the process of forcing a solvent from a region of high solute concentration through a membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure (see figure 9-3). This is the reverse of the normal osmosis process, which is the natural movement of solvent from an area of low solute concentration, through a membrane, to an area of high solute concentration when no external pressure is applied. The membrane here is semi-permeable, meaning it allows the passage of solvent but not of solute.

9.5. BIOLOGICAL UNIT OPERATIONS. The destruction of the organic component of many industrial wastes may be accomplished by biological degradation. Wastes which exhibit a biochemical oxygen demand are potentially amenable to biological treatment. Biological processes are usually employed after a substantial proportion of suspended matter has been removed.

9.5.1. Trickling Filters. Trickling filters, similar to those employed for domestic sewage, generally provide effective treatment of organic industrial wastes. Both standard and high-rate trickling filters with recirculation can be used. Trickling filters are reliable treatment devices which are relatively easy and inexpensive to operate and, in general, provide the best type of biological treatment for industrial wastes or for combined sanitary and industrial wastes.

9.5.2. Activated Sludge. The activated sludge process is useful for treating airport industrial wastes where the organic loading is relatively uniform or homogeneous. This method is sensitive to heterogeneous or shock loads and toxic substances and requires careful operating controls.

9.5.3. Aerobic Biological Treatment. In aerobic systems, organisms that respire oxygen grow on the wastes by breaking them down into carbon dioxide, water and new cell mass. Primary treated wastewater enters the aeration unit and mixes with dissolved oxygen and suspended and/or attached microbes. The aerobic microbes convert organic compounds into energy, new cells and residual matter. As the water moves through the clarifier, a portion of the biological solids are separated out of the effluent and are retained within the ATU. The biological solids settle back into the aeration chamber where they serve as seed for new microbial growth. Settled biomass and residuals will accumulate in the bottom of the chamber and must be removed with periodic maintenance. As the biomass creates an oxygen demand, clarification is an important part of generating a high-quality effluent. Many ATUs have a conical-shaped clarifier to promote separation of the biomass. As the cross-sectional area of upflow increases, the fluid velocity decreases.

Once the settling velocity of the biomass is greater than the fluid velocity, the biomass will no longer move upward. During periods of no flow, the biomass will settle back into the aeration chamber. Other ATUs may incorporate in-line filters to separate the biomass from the effluent. Such filters require periodic maintenance to remove the build up of solids. In the aerobic process, organic nitrogen and ammonia are converted to nitrate. Under anoxic conditions (no molecular oxygen), the nitrate is denitrified to nitrogen gas. Some ATUs are designed to provide denitrification as part of their operation. Design modifications include intermittently supplying air and recirculating the nitrified wastewater into the anoxic regions within the treatment unit.

9.5.4. Anaerobic Treatment. In anaerobic treatment systems, microorganisms ferment the wastes to methane and carbon dioxide (CO2) in the absence of oxygen. Anaerobic digestion is a bacterial process that is carried out in the absence of oxygen. The process can either be thermophilic digestion, in which sludge is fermented in tanks at a temperature of 55°C, or mesophilic, at a temperature of around 36°C.

Though allowing shorter retention time (and thus smaller tanks), thermophilic digestion is more expensive in terms of energy consumption needed for heating the sludge.

One major feature of anaerobic digestion is the production of biogas, which can be used in generators for electricity production and/or in boilers for heating purposes.

Automatic Valve Automatic Valve

RO 3 hp Pump

Sink Pump (Dispensing)

Drain

300 Gallon Tank

300 Gallon Tank

Charcoal

Tank

Filter

#1

Charcoal

Tank

Filter

#2

Incoming Water

Discharge Line

Discharge Line

20 Micron

5 Micron

9 Faucet Dispensing Stations

.00010 RO Membrane Filter

.00010 RO Membrane Filter

.00010 RO Membrane Filter

.00010 RO Membrane Filter

Last Stage Carbon

Filter

UV Light Air Bladder

Figure 9 - 3. Reverse Osmosis (RO)

9.5.5. Sequencing Batch Reactor. Sequencing Batch Reactors (SBRs) or Sequential Batch Reactors are industrial processing tanks for the treatment of wastewater (see figure 9-4). SBR reactors treat wastewater such as sewage or output from anaerobic digesters or mechanical biological treatment facilities in batches. Oxygen is bubbled through the wastewater to reduce BOD5 and COD to make

suitable for discharge into sewers or for use on land. The process includes filling, aeration, settling, and decanting.

While there are several configurations of SBRs, the basic process is similar. The installation consists of at least two identically equipped tanks with a common inlet that can be switched between them. The tanks have a “flow through” system, with raw wastewater (influent) coming in at one end and treated water (effluent) flowing out the other. While one tank is in settle/decant mode, the other is aerating and filling. At the inlet is a section of the tank known as the bio-selector. This consists of a series of walls or baffles which direct the flow either from side to side of the tank or under and over consecutive baffles. This helps to mix the incoming influent and the returned activated sludge, beginning the biological digestion process before the liquor enters the main part of the tank.

The aeration stage involves adding air to the mixed solids and liquid either by the use of fixed or floating mechanical pumps or by blowing it into finely perforated membranes fixed to the floor of the tank. During this period, the inlet valve to the tank is open and a returned activated sludge pump takes mixed liquid and solids (mixed liquor) from the outlet end of the tank to the inlet. This provides the incoming sewage with live bacteria. Aeration times vary according to the plant size and the composition/quantity of the incoming liquor but are typically 60 to 90 minutes. The addition of oxygen to the liquor encourages the multiplication of aerobic bacteria which consume the nutrients. This process encourages the production of nitrogen compounds as the bacteria increase their number, a process known as nitrification. To remove phosphorus compounds from the liquor, aluminum sulphate (alum) is often added during this period. It reacts to form non-soluble compounds, which settle into the sludge in the next stage.

The settling stage is usually the same length in time as the aeration. During this stage, the sludge formed by the bacteria is allowed to settle to the bottom of the tank. The aerobic bacteria continue to multiply until the DO is all but used up. Conditions in the tank, especially near the bottom, are now more suitable for the anaerobic bacteria to flourish. Many of these, and some of the bacteria which would prefer an oxygen environment, now start to use nitrogen as a base element and extract it from the compounds in the liquid, using up the nitrogen compounds created in the aeration stage. This is known as de-nitrification.

High Level

(React) Decant

Pump

Effluent

Decant System

or Primary Effluent

in

Raw

Aerators

Low Level

Figure 9 - 4. Sequencing Batch Reactor (SBR)

TERTIARY AND OTHER TREATMENT TECHNOLOGIES

As the bacteria multiply and die, the sludge within the tank increases over time and a waste activated sludge pump removes some of the sludge during the settle stage to a digester for further treatment. The quantity of sludge within the tank is closely monitored, as this can have a marked effect on the treatment process. The sludge is allowed to settle until clear water is on the top 20%-30% of the tank contents.

The decanting stage most commonly involves the slow lowering of a scoop or trough into the basin. This has a piped connection to a lagoon where the final effluent is stored for disposal to a wetland, tree growing lot, ocean outfall, or to be further treated for use on parks, golf courses, etc.

9.5.6. Wetlands. Sub-surface flow wetlands are typically used where the wastewater being treated is noxious or odorous; where a higher degree of freeze protection is desired; where the attraction of wildlife (especially waterfowl) may be undesirable (e.g., at airports); and/or where ample, economic supplies of suitable substrate material are readily available.

These wetlands consist of submerged gravel beds constructed below ground level. To the untrained eye, they are difficult to discern from open fields. Technically, they are wetlands because wetland plants can grow in them, though there is no open water. Their water surfaces are typically 12 inches (30.5 cm) below their mulch and unsaturated gravel surfaces.

They can be operated either with the wastewater flowing horizontally through the bed or with the water percolating down vertically through the gravel. Bacteria attached to the gravel are responsible for pollutant removal. For high-strength deicing liquids, aeration of the bed is required to assist the bacteria in metabolizing the glycol.

Engineered wetlands are semi-passive constructed wetlands designed so that operating and process conditions can be modified, manipulated, and/or controlled, in contrast to the more passive operation of ordinary constructed wetlands. With engineered wetlands, higher levels of contaminant removals are possible at higher throughputs and with much shorter residence times. Constructed wetland systems can be “engineered” in many ways to improve performance greatly.

An aerated vertical subsurface flow (SSF) engineered wetland is one kind in which air (supplied by blowers) is introduced under thicker gravel substrate (4 – 12 feet (1.2 - 3.7M) thick). Aeration air flows up through the gravel from a buried fine bubble diffusion system, countercurrent to downward percolating wastewater. The vegetated gravel surfaces of engineered wetlands are insulated with layers of mulch or compost to prevent freezing problems, and the systems are designed to operate throughout northern winters — whatever the ambient air temperatures.

9.6. TERTIARY AND OTHER TREATMENT TECHNOLOGIES. Technologies used for tertiary treatment of industrial wastewater include: ion exchange, electrolytic recovery, air stripping, and adsorption.

9.6.1. Ion Exchange. In the ion exchange process, charged ions in the influent industrial wastewater are electrostatically attracted to ion-exchange resins to produce an effluent in which certain elements have been exchanged for others. The resins themselves are not altered chemically and can readily be regenerated, depending on the resin, by the use of a salt, base, or acid. This method is used to remove cyanides and chromates from rinse water, remove impurities from chromic acid plating and anodizing solutions, and produce demineralized water from raw water.

9.6.2. Electrolytic Recovery. In electrolytic recovery, industrial wastewater is subjected to a direct electrical current to achieve specific oxidation and reduction reactions in a manner similar to that employed in electroplating. By this method, heavy metals are removed from industrial wastewater by

SLUDGE HANDLING

plating them onto electrodes. Cyanide oxidation can also be accomplished by this technique. A major advantage to airport operators in using the electrolytic recovery technology for metal removal as compared to conventional treatment technologies, such as precipitation, is that little or no sludge generated by this method requires disposal as a hazardous waste.

9.6.3. Air Stripping and Adsorption. Air stripping and activated carbon adsorption are technologies commonly used for the removal of solvents and other toxic organic compounds from industrial wastewater. In air stripping, water is contacted with air in a countercurrent flow stripping tower which effects the partitioning of the organic compound from the water into the air. In activated carbon adsorption, wastewater is passed through a column packed with granular activated carbon. Organic compounds in the industrial wastewater are removed by adsorption onto the activated carbon. In some cases, bacterial growth within the pores of the activated carbon allows for biological degradation of organic compounds which extends the adsorption capacity of the activated carbon. Once its adsorption capacity is exhausted, the carbon is disposed of or regenerated in a furnace. The use of these technologies will probably increase in the future when more stringent discharge standards for toxic organics are developed and enforced.

9.7. TREATABILITY STUDIES. There is no standard method for treating industrial wastes, as each airport’s industrial plant effluent presents a special treatment problem. Laboratory and pilot-plant studies may be required to determine the type of treatment required for a particular waste. Depending on waste characteristics, combinations of these basic procedures may be implemented to provide the required degree of treatment. Some treatability studies have been conducted for the treatability of glycol but the USEPA is still evaluating which technologies are best for airport waste.

9.8. SLUDGE HANDLING. With the exception of sludges that are either listed or characteristic hazardous wastes (e.g., sludges from electroplating or metal finishing that contain certain heavy metals or cyanides), organic sludge resulting from industrial waste treatment is dried and disposed of in the same manner as sanitary sewage sludge. Organic sludge may be handled by the digestion methods used in wastewater treatment facilities. Sludge drying may be accomplished on open beds, vacuum filters or the more common belt filter presses. Belt presses squeeze water out of the matter to form a cake of a certain percentage solids. The sludge cake is usually hauled offsite for incineration or land application. Industrial wastes containing large quantities of chemical coagulants generally produce a large volume of sludge that ordinarily does not dry as rapidly as sanitary sewage sludge.

CHROMIC ACID RECOVERY

CHAPTER 10. MANAGEMENT OF MAINTENANCE SHOP WASTES

10.1. GENERAL. The operations conducted at aircraft maintenance shops include cleaning, reconditioning, and overhauling aircraft. The principal wastes produced, in addition to those discussed in Chapter 11, are metal cleaning, treating, and plating solutions. This chapter describes treatment facilities for these major airport industrial wastes, including specific systems for the treatment of chromates and other heavy metals, phenols, and cyanides.

10.2. PLATING ROOM WASTES. Plating room wastes, which are mainly inorganic, consist of acids, cyanides, and heavy metals such as zinc, copper, lead, and chromium. The chief plating room operations contributing to the generation of these wastes are:

10.2.1. Stripping. The use of acidic or alkaline baths to remove undesirable films or coating on the metal to be plated.

10.2.2. Cleaning. The removal of oil, grease, dirt, and corrosion through the use of acidic and alkaline cleaners.

10.2.3. Plating. The process of using a direct electrical current to deposit metal on the material being plated produces metal and cyanide wastes.

10.3. SOURCES AND CHARACTERISTICS OF WASTES. The chief sources of wastes in plating room operations are: dragout losses (solutions carried out of the bath and into overflow rinses on the part being plated); spray losses (chiefly in chrome plating where the gas produced causes a fine spray); and the dumping of spent solutions. The characteristics of plating wastes vary considerably. They may be either acidic or alkaline, depending on the baths used. Chromate baths produce highly acidic wastes while alkaline cleaning baths and cyanides produce alkaline wastes. In general, plating wastes are highly toxic and corrosive.

10.4. PLATING WASTE REDUCTION. Dragout losses may be reduced by providing adequate drainage of the metal being plated and the use of a dragout recovery tank. Spray losses may be reduced by the installation of an exhaust system to recover finely divided spray for return to the solution tank. The use of series rather than parallel rinse tanks reduces water consumption. Drip pans to collect overflow solutions are recommended. Finally, good housekeeping and supervision decrease wastes, prevent improper dumping, and improve the segregation and collection of waste.

10.5. CHROMIC ACID RECOVERY. Streams containing chromates may be treated separately to remove contaminating metals from chrome plating and anodizing solutions. The contaminants are iron, trivalent chromium, copper in plating solutions and aluminum in anodizing solutions. A flow diagram of a chromic acid recovery system is shown in figure 10-l.

CHROMIUM REDUCTION

FROM CHROMIC ACID PROCESS TANK

REGENERANT WASTE TO WASTE ACID STORAGE TANK

TO CHROMIC ACID PROCESS TANK CONCENTRATED CHROMIC ACID PROCESS TANK

CHROME PLATING SOLUTION WASTE STORAGE TANK

ION EXCHANGE

UNIT

EVAPORATOR

H2SO4 REGENERANT

CR CR CR CR CR

Figure 10 - 1. Chromic Acid Recovery

10.5.1. Waste Storage Tank. Spent chrome plating solutions from process tanks are collected in a storage or holding tank for dilution to a suitable chromic acid content. Anodizing solutions may be sufficiently low in chromic acid concentration and require no dilution. Dilution of plating solutions is necessary to avoid damage to the equipment used in the next step, ion exchange. The use of electronic equipment may help to regulate properly the amount of spent chromium at the proper concentrations to the storage tank.

10.5.2. Ion Exchange Equipment. A sulfonic cation exchange resin bed in the hydrogen form is used to exchange the contaminating metals in the solution with hydrogen ions in the resin bed. The purified solutions are then passed to an evaporator. When the accumulated impurities from the plating solutions inhibit the ability of the resin in the exchanger to continue purification, the exchanger is removed from service and the resin is regenerated with sulfuric acid. In the regeneration process, the sulfuric acid removes the contaminating metal ions and restores the exchanger resin to the hydrogen form. The sulfuric acid regenerant waste is treated by neutralization and precipitation.

10.5.3. Evaporator. The chrome plating solutions, which are diluted before passing through the cation exchanger to avoid excessive decomposition of the exchanger resin, are brought back to original concentrations by evaporation before return to the plating process tanks.

10.5.4. Chromic Acid Storage Tank. The purified and concentrated chromic acid is stored and returned to the plating process tanks as required.

10.6. CHROMIUM REDUCTION. Another method of treating chromate wastes is by the reduction of the chromate ion through the addition of ferrous sulfate, followed by neutralization with lime to precipitate heavy metals (see figure 10-2). Normally, batch treatment is used. The waste is discharged to acid-resistant tanks equipped with mixing devices, skimmers, baffled decanting outlets, and sludge withdrawal ports. Chemical doses for waste treatment are approximately twice the theoretical amount of either ferrous sulfur dioxide or barium. Following thorough mixing and a standing period of approximately one hour, oil and grease are skimmed from the top. Milk of lime is then added until the pH of the mixture is approximately 8.0. This mixture is then agitated and allowed to settle for a period of approximately 12 hours. The supematant liquor is then decanted and the sludge removed.

PHENOLIC WASTES

MIXING REDUCING AGENT FEED

pH CONTROL POINT

SUPERNATANT LIQUID TO SEWER

SLUDGE DRAWOFF (SLUDGE CONTAINS

CHROMIUM AS Cr(OH)3)

ACID FEED (AS NECESSARY)

CHROMIUM (Cr

+6) WASTES

MIXING

ALKALINE AGENT FEED

pH 8.0 ±

Figure 10 - 2. Chemical treatment of chromium wastes

10.7. PHENOLIC WASTES. Concentrated phenol and cresol wastes result from the cleaning of aircraft parts and require separate treatment. Biological treatment in sewage plants of wastes containing phenols and cresols has been used in some cases where the quantity of sewage is sufficient to dilute the phenols to a concentration of not more than 20 ppm. Pretreatment of phenol wastes for oils and suspended solids removal can be accomplished by the air flotation method previously described in paragraph 9.2.7.2.

10.7.1. Chemical Oxidation. Figure 10-3 shows a flow diagram of the system used for chemical treatment of phenolic wastes. Concentrated phenol and cresol wastes are collected in a receiving tank

CYANIDE WASTES

with a capacity sufficient to hold at least the daily flow of these wastes. The tank contents are then transferred to the phenol oxidation tank where the pH of the phenol bearing wastes is raised by the addition of lime. Chemicals, such as alum or ferrous sulfate, are added to assist in coagulating the solids in the waste. The entire contents of the tank are then mixed and allowed to stand for a time to permit sludge and scum to separate out of the liquid. After separation, the scum and sludge are removed by oil skimming and sludge scraping mechanisms in the tank. Chlorine is added and the tank contents are thoroughly mixed to ensure complete oxidation of the phenols.

PHENOL RECEIVING

TANK

PUMP STATION

PUMPS

SLUDGE & SCUM BATCHED & HAULED

PHENOL OXIDATION TANK

CHLORINE DIOXIDE

FERROUS SULPHATE

LIME

CYANIDE BATCH

TREATMENT

TANK

Figure 10 - 3. Chemical oxidation of phenols

10.7.2. Biological Treatment. Phenols at low concentrations (not greater than 20 ppm) can be treated by biological treatment processes such as trickling filters, the activated sludge process, or a combination of both. In these processes, the wastes, after neutralization with an alkali such as lime, flow to a primary sedimentation tank. The tank effluent flows through a two-stage trickling filter which removes a large part of the BOD5 and phenol content. The effluent from the trickling filter is passed through aeration tanks in which further reduction of phenol content takes place. The effluent flow continues through secondary sedimentation units to remove biological flocs and other suspended materials. If necessary, the effluent flows to a holding pond for further retention before discharge to a stream.

10.8. CYANIDE WASTES. Cyanide wastes are normally treated by the alkaline chlorination method. While either batch or continuous treatment may be used, batch treatment facilities are best for small and medium-size plants.

10.8.1. Batch Treatment. In terms of waste management, batch treatment offers the advantage of positive control of effluent quality, since no wastes need to be discharged until analysis reveals complete cyanide destruction. Cyanide wastes are alternately collected in one of two holding tanks, each having

PAINTING AND PAINT REMOVAL OPERATION.

one day’s capacity of waste flow. While one tank is filling, the contents of the other are being treated (see figure 10-4). Lime or caustic soda is added to raise the pH of the wastes above 8.5, and the pH is then continually maintained at this point by the addition of lime. A minimum pH of 8.5 is required to prevent formation of the toxic gas cyanogen chloride. After a thorough, vigorous mixing, chlorine is added for cyanide destruction. For small-scale operations, the chlorine is often applied in hypochlorite form. The approximate ratio, by weight, of the caustic and chlorine required to treat the cyanide is 10:1, with a minimum exposure period of one hour. Completion of reactions is assured by the application of a slight excess of chlorine.

10.8.2. Waste Release. After destruction of the cyanide, the alkaline wastewater may be mixed with other waste streams and used in neutralizing acid wastes.

WASTE

pH RECORDER INDICATOR

CHLORINATOR

CAUSTIC

SODA

MIXING

TANK

SLUDGE DRAW-OFF

REACTION

TANK

SLUDGE DRAW-OFF

TEST COCK

DISCHARGE TO WASTE SYSTEM OR STREAM

Figure 10 - 4. Cyanide treatment

10.9. PAINTING AND PAINT REMOVAL OPERATION. Facilities should not bury or discard waste paint cans, residuals, or unused paint products on site. Organic solvent-based paints and residuals may be classified as hazardous waste and may require manifesting, storage, transportation, and disposal in full compliance with RCRA (See Section 3.1.2 of this AC for guidance on hazardous waste and 40 CFR 262.34 for guidance on accumulation.). Paint cans (that once contained hazardous waste) that are classified as “empty” by the RCRA definition and latex paints may be recycled or disposed off site at an approved facility as non-hazardous waste.

Metal finishing processes are used to prepare the surface of a part for better adhesion, improved surface hardness, and improved corrosion resistance. Typical metal finishing operations include chemical conversion coating, anodizing, electroplating, and any operation that chemically affects the surface layer of a part. Each of these operations has the potential to significantly impact the environment by discharging metals, cyanides, phosphates, acids, and other contaminants to waterways, soil, or groundwater. Coating Application involves a material being applied to the surface of a part to form a decorative or functional solid film. The most common coatings are primers and topcoats. Facilities can apply coatings to aircraft components using several methods of application, which include spraying,

OILY WASTES.

brushing, rolling, flow coating, and dipping. Nearly all coatings contain a mixture of organic solvents that must be disposed of properly.

10.10. OILY WASTES. Facilities should consider several environmental issues when performing any oil handling activities such as oil changes or oil/fuel filter replacement to motor vehicles, maintenance equipment, and other motors. Most facilities recycle or reclaim used oil. Used oils are regulated under the Used Oil Standards (40 CFR Part 279), and are typically not classified as hazardous wastes at the federal level. However, some states may have stricter disposal requirements. In addition, used oil generators are also subject to all applicable SPCC and underground storage tank (UST) standards. Contact the state regulatory agency to determine the used oil disposal requirements. Facilities should maintain all records on their used oil storage and recycling activities.

SLUDGE DISPOSAL

CHAPTER 11. MANAGEMENT OF AIRCRAFT WASHES AND SIMILAR WASTES

11.1. GENERAL. Discussion in this chapter involves the collection and treatment of wastes from aircraft wash racks, motor vehicle service areas, engine tests cells, engine repair shops, and other activities contributing large quantities of oil, grease, and emulsified wastes.

11.2. WASTE CONTRIBUTORS.

11.2.1. Aircraft Washing. In general, aircraft washing involves the following: 1) pressure spraying the entire aircraft surface with cleaning agents to loosen accumulated oil film, dirt, and oxides; 2) brushing the surfaces with an alkaline water-base cleaner to help loosen foreign matter; and 3) hosing down the surfaces with hot or cold water for thorough removal of emulsified oil, grease, and dirt from the aircraft.

11.2.2. Vehicle Service Areas. Vehicle maintenance wastes result from washing operations and the disposal of used grease and oil.

11.2.3. Engine Repair. Engine repair shop wastes result from cleaning engines and parts with alkaline cleaners.

11.2.4. Engine Test. Engine test cell wastes result from engine and floor cleaning operations and generally contain oil, grease, and emulsified materials.

11.3. AIRCRAFT WASH WASTES TREATMENT AND DISPOSAL. When large quantities of oil, grease, and emulsified wastes are being discharged, it may be necessary to use specifically designed treatment plants. A typical treatment plant consisting of a holding tank and air compression, chemical induction, and flotation units, is shown in figure 11-l and described as follows:

11.3.1. Closed Loop. Many parts washers are closed loop and are self contained units. Typically, an outside contract service company is responsible for collecting and disposing of the parts washer tank wastewater.

11.3.2. Primary Treatment. Raw industrial wastes are piped to a combination holding tank and grit chamber. The tank is provided with devices for the removal of grit, free oil, and free solvent. Usually suitable stirring and mixing devices are installed to keep wastes from stratifying. This type of unit is called an oil/water separator.

11.3.3. Secondary Treatment. The secondary treatment system consists of a continuous operation of flocculation and flotation by air under compression. The components of the system are: inflow pumps, a chemical mixing tank, and mechanical sludge collection equipment for removing floated sludge from the liquid surface in the flotation tank to the sludge trough or hopper. Automatic controls are required for starting and stopping the operation of the inflow pumps at preset liquid levels in the surge tank.