Notice N 8200.121 MLS DME and TACAN Distance Accuracy Tolerances (FAA Order 8200.1C, Chapter 24)

This document is cancelled. Cancelled by 8200.1C. Check the official source before relying on it.

Official source ↗ Open PDF

Text read by OCR from a scanned file. Check the original, as some words may be misread.

NOTICE U.S. DEPARTMENT OF TRANSPORTATION N 8200.121 FEDERAL AVIATION ADMINISTRATION Effective Date: National Policy 8/20/10

Cancellation Date: 8/20/11

SUBJ: MLS DME and TACAN Distance Accuracy Tolerances (Order 8200.1C, Chapter 24)

1. Purpose of This Notice. Microwave Landing System (MLS) Distance Measuring Equipment (DME) and Tactical Air Navigation (TACAN) distance accuracy tolerances in Chapter 24 were changed to reflect "3.0% of charted distance or 0.2 nm, whichever is greater." This change only affects flight inspections applying Chapter 24 criteria to restore service following a major disaster, or establishing service in a military combat/ contingency area.

2. Audience. The audience for this notice is the Air Traffic Technical Operations Eastern, Central, and WesternService Areas; Aviation System Standards Flight Inspection Operations Group offices and crewmembers; Air Force Flight Standards Agency (AFFSA); the 1st Aviation Standards Flight; the U.S. Army Aviation Center, Fort Rucker, Alabama; the Flight Standards Flight Technologies and Procedures Division; and users of FAA Order 8200.1, USSFIM.

3. Where Can I Find This Notice?Go to the Directives Management System (DMS) website: https://employees.faa.gov/tools resources/orders notices/ or the Aviations System Standards website: http://www.avn.faa.gov/index.asp?xml=fioo/notices

4. Background. The old Chapter 24MLS DME tolerance simply said, "3.0% of the charted distance."When applied at distances less than 6.67 nm (the distance at which 3% equals 0.2 nm) this tolerance is more restrictive than the standard ± 0.2 nm tolerance. The old Chapter 24 TACAN DME tolerance (3% of the charted value or 1.0 nm, whichever is greater) allowed an error of ± 1.0 nm up to33.3 nm (where 1 nm equals 3% of the distance). With modern improvements in DME technology, it is reasonable to tighten the tolerance by changing 1.0 nm to 0.2 nm.

5. Guidance. Please make the following pen and ink changes to FAA Order 8200.1C, Chapter 24, Section 4.

a. In Paragraph 24.43, change the Tolerances/ Procedures column for "DME"to read, "No unlocks in final approach segment, accuracy 3.0% of charted distance, or 0.2 nm, whichever is greater.

Distribution: AJW-C/E/W/ 33;AFFSA; 1ASF Initiated By: AJW-331 Air Traffic Technical Operations AviationSystemStandards Flight Inspection Policy

N8200.121 8/20/10

b. In Paragraph 24.45, change the Tolerances/ Procedures column for “Distance Accuracy" to read, “3% of charted distance or 0.2 nm, whichever is greater."

The above guidance will be incorporated in the next change to FAA Order 8200.1C. For additional information, please contact Don McGough, Flight Inspection Policy, 405-954-3050.

Thomas C. Accardi Director of Aviation System Standards