Order CT 3900.55A Occupational Safety and Health
This document is no longer current. Cancelled by CT 3900.55B. Check the official source before relying on it.
Text read by OCR from a scanned file (2 of 156 pages). Check the original, as some words may be misread.
CT 3900.55A
CT 3900.55A
OCCUPATIONAL SAFETY AND HEALTH
January 27, 2006
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
Distribution: A-Z-5 Initiated by: ACX-42
ii
CT 3900.55A
i
RECORD OF CHANGES DIRECTIVE NO. REC NO
CHANGE SUPPLEMENTS OPTIONAL CHANGE SUPPLEMENTS OPTIONAL TO BASIC
TO BASIC
CT 3900.55A
iiii
CT 3900.55A
iii
FOREWORD
It is the policy of the William J. Hughes Technical Center to provide a safe and healthful work environment for all employees, visitors, contractor employees, and employees of other Federal agencies.
This Occupational Safety and Health Order has been prepared in an effort to prevent injuries, illnesses, and death from work related causes and to minimize losses of material resources and interruptions due to accidental occurrences. It is directed toward the control of all types of hazards encountered in the performance of official duties.
This Order is a part of a continuing program for providing safety information to personnel. We all share in the responsibility for the safety and health of our employees, contractors, and visitors. Use this Technical Center Order to ensure a safe and healthful working environment for all of us at the William J. Hughes Technical Center. //S// (original signed on 1/27/06) Ronald Esposito Acting Director, FAA William J. Hughes Technical Center
CT 3900.55A
iv
TABLE OF CONTENTS
CHAPTER 1. ADMINISTRATION
1. Purpose. 1
1.1. Distribution. 1
1.2. Cancellation. 1
1.3. Background. 1
1.4. Standards. 1
1.5. Occupational Safety And Health Program Requirements. 2
1.6. Definitions. 2
1.7. Responsibilities Of The Center. 3
1.8. Responsibilities Of All Center Supervisors And Employees. 4
CHAPTER 2. PERSONAL PROTECTIVE EQUIPMENT
2. Purpose. 5
2.1. Program Components. 5
2.2. Description And Use Of Personal Protective Equipment. 6
2.3. Training. 8
2.4. Recordkeeping. 8
2.5. Procurement. 8
2.6. Other Documents. 8
Figure 2-1 Hazard Assessment Certification For Personal Protective Equipment. 9
Figure 2-2 Glove Chart. 12
CHAPTER 3. MEDICAL SURVEILLANCE PROGRAM
3. Purpose. 13
3.1. Medical Surveillance Requirements. 13
3.2. Medical Examination Requirements. 13
3.3. Medical Recordkeeping. 14
CHAPTER 4. INDUSTRIAL HYGIENE PROGRAM
4. Purpose. 15
4.1. Industrial Hygiene Surveys And Hazard Assessments. 15
CT 3900.55A
v
4.2. Workplace Monitoring. 15
4.3. Equipment. 15
4.4. Recordkeeping. 16
CHAPTER 5. RESPIRATORY PROTECTION PROGRAM
5. Purpose. 17
5.1. Medical Evaluation. 17
5.2. Selection And Use Of Respiratory Protective Devices. 17
5.3. Respirator Training. 19
5.4. Respirator Fit Testing. 19
5.5. Qualitative Fit Testing. 20
5.6. Quantitative Fit Testing. 20
5.7. Special Problems. 20
5.8. Maintenance And Issuance Of Respirators. 21
5.9. Issuance Of Respirators. 21
5.10. Storage. 21
5.11. Program Evaluation. 21
5.12. Recordkeeping. 22
5.13. Contractors. 22
5.14. Voluntary Use Of Respirators. 22
CHAPTER 6. HEARING CONSERVATION PROGRAM
6. Purpose. 23
6.1. Noise Evaluation And Surveillance Procedures. 23
6.2. Noise Control Methods. 24
6.3. Medical Surveillance. 25
6.4. Training. 26
6.5. Program Evaluation. 26
6.6. Recordkeeping. 26
6.7. Other Documents. 26
CT 3900.55A
vi
CHAPTER 7. ERGONOMICS PROGRAM
7. Purpose. 27
7.1. Hazard Identification/Analysis. 27
7.2. Hazard Prevention And Control. 27
7.3. Training. 28
7.4. Recordkeeping. 28
CHAPTER 8. INDOOR AIR QUALITY
8. Purpose. 29
8.1. Definitions. 29
8.2. Building Design And Maintenance Considerations. 29
8.3. Indoor Equipment Use. 30
8.4. Investigation Guidelines. 31
8.5. Mold. 31
8.6. Interpretation Of Survey Results. 31
8.7. Remediation And Control. 32
Table 8-1 Acceptable Ranges of Temperature and Humidity during Summer and Winter. 32
CHAPTER 9. RADIATION PROGRAM
9. Purpose. 33
9.1. Procurement. 33
9.2. Inventory. 33
9.3. Ionizing Radiation. 33
9.4. Equipment Containing Sealed Sources. 33
9.5. Labeling. 34
9.6. Non-Ionizing Radiation. 34
9.7. Monitoring. 35
9.8. Training. 36
9.9. Medical Surveillance. 36
9.10. Recordkeeping . 36
9.11. Other Requirements. 36
CT 3900.55A
vii
CHAPTER 10. INFECTIOUS MATERIALS/BLOODBORNE PATHOGENS
10. Purpose. 37
10.1. Exposure Control Procedures. 37
10.2. Personal Protective Equipment. 37
10.3. Housekeeping. 37
10.4. Hepatitis B Vaccination. 37
10.5. Training. 37
10.6. Recordkeeping. 38
10.7. Evaluating An Exposure Incident. 38
10.8. Contractors. 38
CHAPTER 11. BIOLOGICAL & LYME DISEASE PREVENTION
11. Purpose. 39
11.1. General Requirements. 39
11.2. General Requirements - Stings, Bites, And Allergies. 39
11.3. Poison Ivy, Oak, And Sumac. 41
CHAPTER 12. LABORATORY SAFETY
12. Purpose. 43
12.1. Chemical Hygiene Plan. 43
12.2. Radiological Hazards. 43
12.3. Toxic Materials. 43
12.4. Hazard Warning Signs And Labels. 43
12.5. Hazard Containment. 43
12.6. Safe Work Practices. 44
12.7. Personal Protective Equipment (PPE). 44
12.8. Compressed Gases. 44
12.9. Safe Use Of Laboratory Equipment And Facilities. 45
12.10. Hazard Waste Disposal Methods. 45
CHAPTER 13. TEMPERATURE
13. Purpose. 47
CT 3900.55A
viii
13.1. Cold Environments. 47
13.2. Hot Environments. 47
CHAPTER 14. OFFICE SAFETY
14. Purpose. 49
14.1. Housekeeping. 49
14.2. Electrical Safety. 49
14.3. Noise. 49
14.4. Indoor Air Quality. 50
CHAPTER 15. FIRE SAFETY
15. Purpose. 51
15.1. Fire Prevention . 51
15.2. Fire Protection. 54
15.3. Employee Life Safety Issues. 54
Figure 15-1 Hot Work Permit Form. 55
Figure 15-2 Coffee Station Form. 56
Figure 15-3 Coffee Station Inspection Form. 57
CHAPTER 16. CONTRACTOR SAFETY
16. Purpose. 59
16.1. Responsibilities. 59
16.2. Organization Requesting Contract Services. 59
16.3. Contracting Officer’s Technical Representative. 59
16.4. Safety Office. 60
16.5. Contractor. 60
16.6. Health And Safety Plan. 60
16.7. Pre-Construction Meeting. 60
16.8. Fire Prevention And Protection. 60
16.9. Noncompliance With Safety And Health Requirements. 61
16.10. Safety Training. 61
16.11. Medical Clearance. 61
CT 3900.55A
ix
16.12. Incident Reporting. 61
16.13. Safety And Personal Protective Equipment. 61
16.14. Documentation. 61
CHAPTER 17. GENERAL SHOP SAFETY
17. Purpose. 62
17.1. Employee Training. 62
17.2. Personal Protective Equipment (PPE). 62
17.3. Shop Layout. 62
17.4. Illumination. 62
17.5. Exits And Exit Markings. 63
17.6. Housekeeping. 63
17.7. Fire Prevention . 63
17.8. Material Storage. 64
17.9. Use Of Tools. 64
17.10. Use Of Compressed Air Sources. 64
17.11. Machine Guarding. 64
17.12. Local Exhaust. 64
CHAPTER 18. HAZARD COMMUNICATION PROGRAM
18. Purpose. 65
18.1. Hazard Communication Program. 65
18.2. Multi-Employer Workplaces. 66
18.3. Trade Secrets. 67
18.4. Chemical Purchases. 67
18.5. Eyewash And Emergency Showers. 67
18.6. Other Documents. 67
CHAPTER 19. LOCKOUT/TAGOUT PROGRAM
19. Purpose. 69
19.1. General Requirements. 69
19.2. Training. 70
CT 3900.55A
x
19.3. Inspection. 71
19.4. Equipment Testing. 71
19.5. Group And Shift-Change Lockout/Tagout Procedures. 72
19.6. Contractors. 72
CHAPTER 20. CONFINED SPACE ENTRY PROGRAM
20. Purpose. 73
20.1 Definitions. 73
20.2. General Requirements. 74
20.3. Training. 75
20.4. Personnel Requirements. 76
20.5. Testing And Monitoring. 76
20.6. Acceptable Entry Conditions. 77
20.7. Safety Equipment And Clothing. 77
20.8. Work Practices. 77
20.9 Rescue And Emergency Services. 78
20.10. Contractors. 78
20.11. Other Documents. 78
Figure 20-1 Confined Space Permit Form. 79
CHAPTER 21. MACHINERY AND EQUIPMENT
21. Purpose. 81
21.1. Hand-Held And Portable Powered Tools . 82
21.2. Explosive Actuated Fastening Tools. 83
21.3. Air Compressor And Receiver. 83
21.4. Fork Lifts - General Requirements. 83
Figure 21-1 Forklift Safety Checklist. 85
CHAPTER 22. CUTTING AND WELDING
22. Purpose. 87
22.1. Operating Procedures. 87
22.2. Personal Protective Equipment. 88
CT 3900.55A
xi
22.3. Fire Prevention And Protection. 88
22.4. Welding And Cutting Tanks, Cylinders, Or Containers. 88
22.5. Arc Welding. 89
22.6. Portable Gas Units. 89
CHAPTER 23. PAINTING OPERATIONS
23. Purpose. 91
23.1. Fire Prevention And Protection. 91
23.2. Ventilation. 91
23.3. Storage And Handling. 92
23.4. Electrical. 92
23.5. Location Of Paint Shops And Spray Finishing Operations. 92
23.6. Airless Paint Spraying. 93
23.7. Paint Spray Booths. 93
23.8. Portable Paint Spray Equipment. 93
23.9. Aerosol Spray Paint Cans. 93
CHAPTER 24. LEAD PAINT REMOVAL
24. Purpose. 95
24.1. Identification Of Lead-Based Paints (LBP). 95
24.2. LBP Abatement / Removal. 95
24.3. Work Practices. 95
24.4. General Practices. 96
24.5. Protective Measures. 96
24.6. Cutting/Brazing/Welding. 97
24.7. Waste Disposal. 97
24.8. Other Wastes. 97
CHAPTER 25. WORKING AT ELEVATIONS
25. Policy. 98
25.1. Responsibilities . 98
25.2. Ladders. 98
CT 3900.55A
xii
25.3. Scaffolding And Elevated Platforms. 100
25.4. Rooftop Work. 101
25.5. Personal Fall Arrest Systems. 101
25.6. Training Program. 104
Figure 25-1 Anchorage Plates. 105
Figure 25-2 Full Body Harness. 106
CHAPTER 26. EXCAVATION AND TRENCHING
26. Purpose. 107
26.1. Excavation And Trenching. 107
26.2. Excavation And Trenching Protective Systems. 107
26.3. Access And Egress. 108
26.4. Exposure To Vehicular Traffic. 108
CHAPTER 27. MOTOR VEHICLE SAFETY
27. Purpose. 109
27.1. General Requirements. 109
27.2. Motor Vehicle Accident Reporting. 110
CHAPTER 28. FITNESS ACTIVITIES
28. Purpose. 111
28.1. Fitness Center. 112
28.2. Sports Leagues. 112
28.3. Weather Conditions. 112
CHAPTER 29. SAFETY AWARDS PROGRAM
29. Background. 113
29.1. Recognition. 113
29.2. Procedures. 113
29.3. Eligibility. 113
29.4. Awards. 113
Figure 29-1 Safety Recognition Nomination Form. 114
CHAPTER 33. SAFETY INSPECTIONS
CT 3900.55A
xiii
CHAPTER 30. MISHAP REPORTING and REPORTING UNSAFE OR UNHEALTHFUL CONDITIONS
30. Purpose. 115
30.1. Procedures. 115
30.2. Reporting Schedule. 115
30.3. Contractor And Contracting Officer Reports. 115
30.4. Other Reporting Procedures. 116
Figure 30-1 FAA Mishap Report Form. 117
CHAPTER 31. SAFETY AND HEALTH PLANS FOR TESTING OPERATIONS
31. Purpose. 119
31.1. Policy. 119
31.2. Responsibilities. 119
31.3. Review And Approval Of Test Plans. 119
31.4. Test Plan Format. 120
31.5. Structure For Safety And Health Test Plan. 120
31.6. Outline Of Testing Operation Plan. 120
CHAPTER 32. ASBESTOS PROGRAM
32. Purpose. 122
32.1. Applicable Standards. 122
32.2. Definitions. 122
32.3. Asbestos Inventory and Hazard Assessment. 124
32.4. Abatement/Removal. 124
32.5. In-Place Management/Operations and Maintenance. 124
32.6. Exposure Limits. 126
32.7. Medical Surveillance. 126
32.8. Waste Disposal . 126
32.9. Recordkeeping. 127
CHAPTER 33. SAFETY INSPECTIONS
33.1. Purpose. 128
33.2. Responsibilities. 128
CT 3900.55A
xiv
33.3. Communications and Notifications. 128
33.4. Inspection Process. 128
33.5. Reports and Procedures. 128
33.6. Inspection References. 128
CHAPTER 34. SEAT BELT SAFETY
34.1. Purpose. 130
34.2. Responsibilities. 130
34.3. Executive Order 13043. 131
CHAPTER 35. SAFETY AND ENVIRONMENTAL REPRESENTATIVES COMMITTEE (SAFERCOM)
35.1. Purpose. 133
35.2. Distribution. 133
35.3. Status. 133
35.4. Background. 133
35.5. Definitions. 133
35.6. Duties and Functions. 134
35.7. Structure. 135
35.8. Membership. 135
35.9. General. 135
35.10. Public Participation. 136
35.11. Availability of Records. 137
35.12. References. 137
35.13. Appendix 1, SAFERCOM Representative. 138
35.14. Appendix 2, Training Outline. 139
1. PURPOSE. › 1.3. BACKGROUND.
CHAPTER 1. ADMINISTRATION
1. PURPOSE.
The purpose of the Federal Aviation Administration (FAA) William J. Hughes Technical Center Safety and Health Order is to provide employees with general guidelines for implementing a high quality Occupational Safety and Health (OSH) program. It is not an exhaustive source document but rather an approach to safety.
The Order brings together information that will assist employees and supervisors in carrying out their responsibilities in ensuring a safe environment at the William J. Hughes Technical Center for visitors, contractors, and employees. All personnel should read this Order and conduct their work accordingly.
1.1. DISTRIBUTION.
This order is distributed through supervisors, including tenants and contractors.
1.2. CANCELLATION. The following Orders are canceled:
a. CT 3900.16, Hot Work Permits.
b. CT 3900.9B, Fire Protection and Life Safety
Program, dated December 14, 1979.
c. CT 3900.13B, Personal Protective Equipment and
Clothing, dated August 18, 1993. d. CT 3900.20A, NAFEC Occupational Safety Policy,
dated August 2, 1979.
e. CT 3900.21A, Licensing of Coffee Stations and
Hot Pots in Technical Building, dated May 17, 1984.
f. CT 3900.49, Control of Hazardous Energy During
Maintenance, Servicing and Repair - Lock out/Tag out Program, dated July 17, 1993.
g. CT 3900.24, Safety and Health Plans for Testing
Operations, dated May 8, 1992.
h. CT 3900.25, Respiratory Protection Program, dated
November 8, 1993.
1.3. BACKGROUND.
This Order is a part of a continuing program for providing safety information to personnel. The information and requirements given in this Order are applicable to all areas of the William J. Hughes Technical Center and represent only general minimum standards. They do not substitute for special operation Orders used in certain buildings or laboratories to meet specific situations. This Order will serve as a basis to which supervisors shall add safety measures relevant to their laboratory or work operations. It must be emphasized that this is a Technical Center Order. The procedures and requirements are established based on the facilities and resources available at the William J. Hughes Technical Center. They represent, nonetheless, a code of standard safe work practices for use at other institutions.
1.4. STANDARDS.
The Occupational Health and Safety Program is established in accordance with the following references:
a. Executive Order 12196, Occupational Safety and
Health Programs for Federal Employees.
b. Section 19(a), Public Law 91-596, Williams -
Steiger Occupational Safety and Health Act, Federal Agency Safety Programs and Responsibilities.
c. Basic Program Elements for Federal Employee
Occupational Safety and Health Programs; Final Rule, Occupational Safety and Health Administration (OSHA), Department of Labor, 29 CFR 1960.
d. 29 CFR 1910, “Occupational Safety and Health
Standards for General Industry, “ and 29 CFR 1926, “Safety and Health Regulations for Construction.”
e. Existing FAA OSH orders. This Center’s OSH
program and related FAA orders shall be periodically reviewed for currency with OSHA standards and FAA organizational changes. For Center safety orders found to be inconsistent due to changes in OSHA standards, the most current OSHA standard shall apply.
f. Consensus Standards. FAA will apply OSHA
standards and other non-FAA regulatory or current industry/consensus standards to equipment, operations, or workplaces. Non-FAA regulatory or consensus standards include, but are not limited to, those published by the American National Standards Institute (ANSI), American Society for Testing and Materials (ASTM), Environmental Protection Agency (EPA), National Fire Protection Agency (NFPA), and the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE).
1.5. OCCUPATIONAL SAFETY AND HEALTH PROGRAM REQUIREMENTS.
The Center OSH program shall include the following:
a. Program Elements. The elements of an occupational
safety and health program include:
1. A safety and health organization consistent with this order and with OSHA regulations.
2. Safety and health committees at the Center level. The Safety and Environmental Representatives Committee (SAFERCOM) was established in January 1993. This committee advises and assists management in implementing and monitoring safety and health programs and provides a forum for information exchange.
3. Qualified safety and health professionals with equipment, competence, and training available to recognize and evaluate workplace hazards and to suggest means to abate those hazards.
4. A safety awards program aimed at promoting positive employee response and personal accountability in safety and health activities.
5. Written policies, programs, and procedures that provide appropriate direction, guidance, and program requirements.
6. Budgets and plans at each operating level or line of business, ensuring appropriate financial and other resources are requested for OSH program implementation and administration.
7. A safety and health management information system to record and track accidents, injuries, and illnesses.
8. A program to transmit information on
pending safety and health legislation or new regulations to appropriate staff: e.g. use of intranet homepages, subscription to a reporting service, staff meetings, etc.
b. Training. A comprehensive occupational safety and
health training program shall be established to incorporate general and job-specific training based on an individual’s duties and the workplace.
c. Workplace inspection and abatement. Formal
facility inspections shall be conducted annually and recorded through the Environmental and Safety Information System Annual Inspection Program (ESIS AIP 2000). ESIS AIP is a tool to assist inspectors in conducting Environmental and Occupational Safety and Health inspections at Center facilities. Formal procedures for hazard abatement will be established and tracked through the Center’s work request system.
d. Measures of effectiveness. The Center OSH
program will be audited and evaluated to track its success quantitatively and to identify areas requiring increased attention. In addition to the auditing performed to maintain certification in International Standards Organization (ISO) 9001 Quality Management System for certain OSH functions, the entire Center OSH program will be subject to periodic reviews by headquarters.
e. Dissemination of occupational safety and health
program information. A copy of this order and related headquarters OSH orders and implementation guidelines shall be made available for inspection to each supervisor, SAFERCOM committee members, employee representatives, and employees.
1.6. DEFINITIONS
a. Center refers to the William J. Hughes Technical
Center
b. Designated Agency Safety and Health Official
(DASHO) is the individual responsible for the management and administration of the safety and health program in the agency. At the headquarters level, the DASHO is the Division Manager of the Environmental, Energy, Occupational, Safety and Health (EEOSH) Group at ATO-W EEOSH Services. At the Center, the Center Director will appoint a Designated Region/Center Safety and Health Official (DR/CSHO) based on need.
c. Facility is a single physical location where business
is conducted or where services or operations are performed. This includes those operations occupied
by contractors or tenants.
d. Management Representative is a supervisor or
management official as defined in labor management relations program.
e. Regional/Center Occupational Safety and Health
Manager (ROSHM/COSHM) is the technical person responsible for the employee safety and health program at the regional and center level. The ROSHM/COSHM serves as advisor to the RPMES and management on occupational safety and health issues and is a permanent voting member of the SAFERCOM.
f. Regional Program Manager for Environment and
Safety (RPMES) serves as the regional and center associate program manager in performing the environmental compliance and occupational safety and health program implementation responsibilities and providing implementation guidance for compliance at regional division levels. The RPMES maintains copies of the SAFERCOM minutes and reports and is a permanent, voting member of the SAFERCOM.
g. Technically Qualified Safety Personnel:
1. OSH Professionals: safety specialists, safety managers, safety engineers, or industrial hygienists; or equally qualified agency, military, or non-government personnel who meet the basic qualifications of the above classifications as defined by AHR standards and recommended by the ROSHM.
2. Collateral Duty Safety and Health (CDSH) Personnel: personnel having sufficient OSH training and experience as determined by the ROSHM to perform general workplace safety inspections.
1.7. RESPONSIBILITIES OF THE CENTER.
a. The Director, William J. Hughes Technical Center
shall:
1. Provide top management commitment and support for the OSH program, to include the enforcement of safety regulations.
2. Ensure that the Center’s programs address OSH requirements in the planning, funding, and operation process.
3. Incorporate applicable OSH requirements into specifications as well as contracts for inspection, construction, maintenance, and
replacement of airway systems, facilities, and equipment; and acquisition of goods and services.
4. Designate a safety and health official as the DR/CSHO based on Center needs and preferences.
5. Ensure adequate funds and resources are requested to comply with applicable OSH policies and regulations like training, travel, and PPE. These requests should be made through the appropriate line of business.
6. Provide OWCP information to ROSHM’s/COSHM’s through the Safety Management Information System for accident prevention purposes.
b. Facilities Services and Engineering Division
Director shall:
1. Provide top management commitment and support for OSH program.
2. Manage and coordinate the implementation of the Center OSH program across division/staff office boundaries in include planning and funding functions, as applicable.
3. Assist division/staff offices in implementing the OSH program in their organizations.
4. Ensure Center resource requirements for OSH programs identified by all divisions are submitted to HQ.
5. Provide an adequate number of technically qualified staff to support the Center OSH program.
6. Ensure procedures are in place to respond to employee reports of unsafe conditions.
7. Ensure written guidance and procedures are in place to expedite the notification of safetyrelated accidents, fatalities, and incidents to the emergency operations facility.
c. All Center Division Managers shall:
1. Provide top management commitment and support for the agency OSH program.
2. Implement OSH policies within their respective organization.
3. Ensure that adequate funds are resources are requested in order to comply with applicable OSH policies and regulations like training, travel, and PPE. These requests should be made through the appropriate line of business.
4. Ensure all divisional programs and projects address current OSH requirements.
5. Designate a representative as a contact point to work with the ROSHM/COSHM on OSH issues.
6. Require supervisors to identify employee OSH training needs and provide input during the annual budget formation.
7. Provide appropriate representation and participation at the SAFERCOM.
8. Appoint and train collateral duty safety personnel to assist in OSH program responsibilities.
1.8. RESPONSIBILITIES OF ALL CENTER SUPERVISORS AND EMPLOYEES
a. All Supervisors shall:
1. Ensure that workplaces are inspected to identify and correct hazards and that completed job safety analyses (JSA) are available for appropriate work practices.
2. Ensure that all employees are trained in safety awareness and in safety precautions appropriate for their assigned tasks. Ensure the training records are documented and maintained in accordance with OSHA standards.
3. Enforce safety rules and regulations and require the use of PPE when it is dictated by job requirements.
4. Ensure that accidents are investigated and that reports are completed to determine why they occurred.
5. Utilize the safety committee, collateral duty, and OSH personnel as a source of advice and assistance.
6. Ensure that all work-related injuries and illnesses are reported in accordance with prescribed procedures.
7. Ensure annual inspections are conducted and documented. Responding to the safety office within 30 days of receipt of inspection reports.
8. Provide commitment to the safety and health program.
b. All Center employees (including tenants and
contractors) shall:
1. Observe safe work practices, including the use of PPE, and comply with FAA and OSHA safety and health policies and standards.
2. Promptly report unsafe and/or unhealthful working conditions, situations, work-related injuries, illnesses, and accidents to supervisors.
3. Attend applicable OSH-related training sessions and committee meetings and comply with medical surveillance requirements.
4. Provide commitment to the safety and health program.
2. PURPOSE.
CHAPTER 2. PERSONAL PROTECTIVE EQUIPMENT
2. PURPOSE.
The objective of the Personal Protective Equipment (PPE) Program is to protect employees from the risk of injury by creating a barrier against workplace hazards. Personal protective equipment is not a substitute for good engineering, administrative controls, or good work practices, but should be used in conjunction with these controls to ensure the safety and health of employees. Personal protective equipment will be provided, used, and maintained when it has been determined that its use is required and that such use will lessen the likelihood of occupational injury and/or illness. This program addresses eye, face, head, foot, body and hand protection. Separate programs exist for respiratory and hearing protection since the need for participation in these programs is established through industrial hygiene monitoring and medical surveillance.
2.1. PROGRAM COMPONENTS.
a. Hazard Assessment and Equipment Selection. The
Safety Office, in conjunction with the supervisors, will conduct a hazard assessment of each work area to identify sources of hazards, including impact, penetration, compression, chemical, heat, dust, electrical sources, material handling, and light radiation. This hazard assessment will include a written certification that identifies the workplace evaluated, the person who performed the evaluation and the date the assessment was conducted (see Figure 2-1) Once the hazards of a workplace have been identified, the Safety Office will determine the appropriate PPE that will ensure a level of protection greater than the minimum required to protect the employees. Care will be taken to recognize the possibility of a multiple and simultaneous exposure to a variety of hazards. Adequate protection against the highest level of each of the hazards will be provided.
b. Protective Devices. All personal protective
clothing and equipment will be of safe design and construction for the work to be performed and shall be maintained in a sanitary and reliable condition. Protective clothing and equipment must meet NIOSH (National Institute of Occupational Safety and Health) or ANSI (American National Standards Institute) standards. Careful
consideration will be given to employee comfort and fit of PPE in order to ensure that it will be used. Consideration should be taken to ensure that the right size is selected. Defective and damaged PPE must not be used.
c. Eye and Face Protection. Prevention of eye
injuries requires that all persons who enter eye hazard areas wear protective eyewear. This includes employees, visitors, researchers, contractors, or others passing through an identified eye hazard area. Suitable protection shall be used when employees are exposed to hazards from flying particles, molten metal, acids or caustic liquids, chemicals, gases, or vapors, or potentially injurious light radiation.
1. Contact lens wearers must also wear appropriate eye and face protection devices in a hazardous environment. Contact lenses may be worn when appropriate eye protection is utilized to prevent inadvertent eye contact with chemical hazards.
2. Side protectors shall be used when there is a hazard from flying objects.
3. Goggles and face shields shall be used as protection from chemical splashes.
4. Face shields shall only be worn over primary eye protection (safety glasses).
5. Protectors shall be marked to identify the manufacturer.
6. Equipment fitted with appropriate filter lenses shall be used to protect against light radiation (i.e. welding/cutting, laser operations). Acceptable filter lenses need to be marked or identified as such.
d. Prescription Safety Eyewear. OSHA regulation
29CFR1910.133(a)(3) require that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards shall wear eye protection that incorporates the prescription in its design, or that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses. Personnel requiring
prescription safety glasses must contact the Safety Office to have their request processed.
e. Emergency Eyewash Facilities. Emergency
eyewash facilities meeting the requirements of ANSI Z358.1 will be provided in all areas where employees may be exposed to corrosive materials. Eyewash facilities should be easily accessible in an emergency situation.
f. Head Protection. Head protection will be
furnished to, and used by, all employees engaged in construction. Head protection is also required to be worn at work sites when hazards from falling or fixed objects, or electrical shock are present.
g. Foot Protection. Safety shoes shall be worn in
areas determined by the Safety Office. All safety footwear shall comply with ANSI Z41-1991, American National Standard for Personal Protection - Protective Footwear. Safety shoes or boots are required to be worn in work areas involving the carrying or handling of materials such as packages, objects, parts or heavy tools, and for other activities where objects might fall onto or over the employee’s feet, or cause a puncture if stepped on.
1. Purchasing Safety Shoes. Safety shoes can be purchased at commercial shoe stores, through catalogues, or any other acceptable means. The supervisor is responsible for making this determination and must submit the purchase request through the Safety Office to receive approval prior to the actual purchase of safety shoes. Any safety shoes purchased at a commercial shoe store must be submitted to the Safety Office for verification that they meet the ANSI standard before being worn on the job.
2. Reimbursement for Safety Shoes. The William J. Hughes Technical Center will either pay or reimburse up to $100 for one pair of safety shoes per year except where the supervisor has justified the purchase of an additional pair. Should the cost of the shoes exceed $100, then the employee must pay the difference except in cases where prescribed protection or special sizing is required. These exceptions will be handled on a per case basis by the supervisor and the Safety Office.
h. Hand Protection. Suitable gloves shall be worn
when hazards from chemicals, cuts, lacerations, abrasions, punctures, burns, and harmful temperature extremes are present. Glove selection
shall be based on the performance characteristics of the gloves, work conditions, duration of use, and hazards present. The first consideration in the selection of gloves for use against chemicals is to determine, if possible, the exact nature of the substances to be encountered. Instructions and warnings listed on chemical container labels and Material Safety Data Sheets (MSDS) will recommend a glove type for protection.
All glove materials are eventually permeated by chemicals. However, they can be used safely for limited time periods if specific use and other characteristics are known.
The Safety Office can assist in determining the specific type of glove material that should be worn for a particular chemical.
2.2. DISCRIPTION AND USE OF PERSONAL PROTECTIVE EQUIPMENT.
a. Eye Protection.
1. Safety Glasses. Protective eyeglasses are made with safety frames, tempered glass or plastic lenses, temples, and side shields which provide eye protection from moderate impact and particles encountered in job tasks such as carpentry, woodworking, grinding, scaling, etc. Safety glasses are also available in prescription form for those persons who need corrective lenses.
2. Single Lens Goggles. Vinyl framed goggles provide adequate eye protection from many chemical splash hazards and impact hazards. These goggles are available with clear or tinted lenses; perforated, port vented, or nonvented frames. Single lens goggles provide similar protection as spectacles and may be worn in combination with spectacles or corrective lenses to insure protection along with proper vision.
3. Welding/Chipping Goggles. These goggles are available in rigid and soft frames to accommodate single or two eyepiece lenses.
(a) Welding goggles provide protection from
sparking, scaling, or splashing metals and harmful light rays. Lenses are impact resistant and are available in graduated shades of filtration.
(b) Chipping/Grinding. Goggles provide eye
protection from flying particles. The dual protective eye cups house impact resistant
clear lenses with individual cover plates.
4. Face Shields. These normally consist of an adjustable headgear and face shield of tinted/transparent acetate or polycarbonate materials, or wire screen. Face shields are available in various sizes, tensile strength, impact/heat resistance, and light ray filtering capacity. Face shields will be used in operations when the entire face needs protection and should be worn to protect eyes and face against flying particles, metal sparks, and chemical splash.
5. Welding Shields. These shield assemblies consist of vulcanized fiber or glass fiber body, a ratchet/button type adjustable headgear or cap attachment, and a filter and cover plate holder. These shields will be provided to protect worker’s eyes and face from infrared or radiant light burns, flying sparks, metal spatter, and slag chips encountered during welding, brazing, soldering, resistance welding, bare or shielded electric arc welding, and oxyacetylene welding and cutting operations.
b. Head Protection. Head injuries are caused by
falling or flying objects, or by bumping the head against a fixed object. Head protectors, in the form of protective hats, must resist penetration and absorb the shock of a blow. The shell of the protective hat is hard enough to resist the blow and the headband and crown straps keep the shell away from the wearer’s skull. Protective hats can also protect against electrical shock. Protective hats are made in the following types and classes:
1. Type 1. Helmets with a full brim.
2. Type 2. Brimless helmets with a peak extending forward from the crown.
(a) Class A. General service, limited voltage.
Intended for protection against impact hazards. Used in mining, construction, and manufacturing.
(b) Class B. Utility service, high voltage.
Used by electrical workers.
(c) Class C. Special service, no voltage
protection. Designed for lightweight comfort and impact protection.
c. Foot Protection. There are many types and styles
of protective footwear and it is important to realize that a particular job may require additional
protection other than listed here. Footwear that meets established safety standards will have an American National Standards Institute (ANSI) label inside each shoe.
1. Steel-Reinforced Safety Shoes. These shoes are designed to protect feet from common machinery hazards such as falling or rolling objects, cuts, and punctures. The entire toe box and insole are reinforced with steel, and the instep is protected by steel, aluminum, or plastic materials. Safety shoes are also designed to insulate against temperature extremes and may be equipped with special soles to guard against slip, chemicals, and/or electrical hazards.
2. Safety Boots. Safety boots offer more protection when splash or spark hazards (chemicals, molten materials) are present:
(a) When working with corrosives, caustics,
cutting oils, and petroleum products, neoprene or nitrile boots are often required to prevent penetration.
(b) Foundry or "Gaiter" style boots feature
quick-release fasteners or elasticized insets to allow speedy removal should any hazardous substances get into the boot itself.
(c) When working with electricity, special
electrical hazard boots are available and are designed with no conductive materials other than the steel toe (which is properly insulated).
d. Hand Protection. Skin contact is a potential
source of exposure to toxic materials and it is important that the proper steps be taken to prevent such contact. Most accidents involving hands and arms can be classified under four main hazard categories: chemicals, abrasions, cutting, and heat.
Gloves should be replaced periodically, depending on frequency of use and permeability to the substance(s) handled. Gloves overtly contaminated should be rinsed and then carefully removed after use.
Gloves should also be worn whenever it is necessary to handle rough or sharp-edged objects, and very hot or very cold materials. The types of glove materials to be used in these situations include leather, welder’s gloves, aluminumbacked gloves, and other types of insulated glove materials.
2. PURPOSE. › All purchase requests or credit card purchases for safety equipment…
The following is a guide to the most common types of protective work gloves and the types of hazards they can guard against:
1. Disposable Gloves. Disposable gloves, usually made of lightweight plastic, can help guard against mild irritants.
2. Fabric Gloves. These gloves are made of cotton or fabric blends and are generally used to improve grip when handling slippery objects. They also help insulate hands from mild heat or cold.
3. Leather Gloves. These gloves are used to guard against injuries from sparks or scraping against rough surfaces. They are also used in combination with an insulated liner when working with electricity.
4. Metal Mesh Gloves. These gloves are used to protect hands from accidental cuts and scratches. They are used most commonly by persons working with cutting tools or other sharp instruments.
5. Aluminized Gloves. Gloves made of aluminized fabric are designed to insulate hands from intense heat. These gloves are most commonly used by persons working with molten materials.
6. Chemical Resistance Gloves. These gloves may be made of rubber, nitrile, neoprene, polyvinyl alcohol, or vinyl, etc. The gloves protect hands from corrosives, oils, and solvents. When selecting chemical resistant gloves, be sure to consult the manufacturer’s recommendations, especially if the gloved hand will be immersed in the chemical. (See figure 2-2 for general guidelines for chemical glove performance.)
2.3. TRAINING.
Any employee required to wear PPE shall receive training in the proper use and care of PPE. Periodic retraining shall be offered by the Safety Office to both the employees and the supervisors, as needed. The training shall include, but not necessarily be limited to, the following subjects:
a. What PPE is necessary.
b. When PPE is necessary to be worn.
c. How to properly don, doff, adjust, and wear PPE.
d. The limitations of PPE.
e. The proper care, maintenance, useful life, and
disposal of PPE.
2.4. RECORDKEEPING. The Safety Office shall maintain training records for at least 3 years including the persons trained, the type of training provided, and the dates of training.
2.5. PROCUREMENT. All purchase requests or credit card purchases for safety equipment must be approved by the Safety Office.
2.6. OTHER DOCUMENTS.
William J. Hughes Technical Center Environmental Branch Safety Office Personal Protective Program.
2. PURPOSE. › … Projectiles
Figure 2-1 HAZARD ASSESSMENT CERTIFICATION FOR PERSONAL PROTECTIVE EQUIPMENT
Date: Location: Organization:
Assessment Conducted By:
Job Title(s):
Specific Tasks Performed at this Location:
Hazard Assessment and Selection of Personal Protective Equipment I. Overhead Hazards
Hazards Identified: … Suspended loads that could fall … Overhead beams or loads that could be hit against … Energized wires or equipment that could be hit against … Employees work at elevated site who could drop objects on others below … Sharp objects or corners at head level … Other …
Head Protection Required Yes No
Hard Hat Type: ____Type A (impact and penetration resistance, plus low-voltage electrical insulation) ____Type B (impact and penetration resistance, plus high-voltage electrical insulation) ___Type C (impact and penetration resistance)
II. Eye and Face Hazards
Hazards Identified:
… Chemical splashes
… Dust … Smoke and fumes … Welding operations … Lasers/optical radiation … Bioaerosols … Projectiles … Other …
____ Te____ Temperature extremes › Foot Protection Required
Eye Protection Required Yes No
____ Safety glasses w/ side shields ____ Goggles ____ Face Shield ____ Other …
III. Hand Hazards
Hazards Identified: ____ Chemicals ____ Sharp edges, splinters, etc. ____ Temperature extremes
____ Biological agents ____ Exposed electrical wires ____ Sharp tools, machine parts, etc. ____ Material handling ____ Other …
Hand Protection Required Yes No
Gloves: ____ Chemical resistant ____ Temperature resistant ____ Abrasion resistant ____ Other … IV. Foot Hazards
Hazards Identified ____ Heavy materials handled by employees ____ Sharp edges or points (puncture risk) ____ Exposed electrical wires ____ Unusually slippery conditions ____ Wet conditions ____ Construction/demolition ____ Other …
Foot Protection Required Yes No
Safety Shoe Types: ____ Toe protection ____ Metatarsal protection ____ Puncture resistant ____ Electrical insulation ____ Other (Explain) …
V. Other Identified Safety and/or Health Hazards:
Hazard Recommended Protection
I certify that the above inspection was performed to the best of my knowledge and ability, based on the hazards present on … (Date) … (Signature)
Figure 2-2 Glove Chart
Type Advantages Disadvantages Use Against
Natural rubber Low cost, good physical properties, dexterity
Poor vs. oils, greases, organics. Frequently imported; may be poor quality
____ Te____ Temperature extremes › Figure 2-2 Glove Chart
Bases, alcohols, dilute water solutions; fair vs. aldehydes, ketones.
Natural rubber blends Low cost, dexterity, better chemical resistance than natural rubber vs. some chemicals
Physical properties frequently inferior to natural rubber
Same as natural rubber
Polyvinyl chloride (PVC) Low cost, very good physical properties, medium cost, medium chemical resistance
Plasticizers can be stripped; frequently imported may be poor quality
Strong acids and bases, salts, other water solutions, alcohols
Neoprene Medium cost, medium chemical resistance, medium physical properties
NA Oxidizing acids, anilines, phenol, glycol ethers
Nitrile Low cost, excellent physical properties, dexterity
Poor vs. benzene, methylene chloride, trichloroethylene, many ketones
Oils, greases, aliphatic chemicals, xylene, perchloroethylene, trichloroethane; fair vs. toluene
Butyl Specialty glove, polar organics Expensive, poor vs. hydrocarbons, chlorinated solvents
Glycol ethers, ketones, esters
Polyvinyl alcohol (PVA) Specialty glove, resists a very broad range of organics, good physical properties
Very expensive, water sensitive, poor vs. light alcohols
Aliphatics, aromatics, chlorinated solvents, ketones (except acetone), esters, ethers
Fluoro- elastomer (Viton) ™ * Specialty glove, organic solvents Extremely expensive, poor
physical properties, poor vs. some ketones, esters, amines
Aromatics, chlorinated solvents, also aliphatics and alcohols
Norfoil (Silver Shield) Excellent chemical resistance Poor fit, easily punctures, poor grip, stiff
Use for Hazmat work
*Trademark of DuPont Dow Elastomers
3. PURPOSE. › 3.1. MEDICAL SURVEILLANCE REQUIREMENTS.
CHAPTER 3. MEDICAL SURVEILLANCE PROGRAM
3. PURPOSE. A medical surveillance program shall be established for the diagnosis and treatment of acute and chronic occupational injuries and illnesses, including collaboration with an employee chosen physician (if desired), to document and assess diagnosis, treatment and care in conjunction with return to work without hampering the healing process. The program will also provide for: fitness for duty examinations, baseline health data to be compared to any subsequent exposures and resultant health effects, and detection of early indicators of excessive exposure to allow for implementation of corrective actions to prevent further exposure.
3.1. MEDICAL SURVEILLANCE REQUIREMENTS. The William J. Hughes Technical Center is required to establish and implement a medical surveillance program and to maintain employee records according to Occupational Safety and Health Administration (OSHA) standards. The medical surveillance program will be implemented in accordance with Federal requirements of OSHA, Environmental Protection Agency (EPA), Nuclear Regulatory Agency (NRA) and Department of Transportation (DOT). Inclusion in the program will be determined by the results of industrial hygiene data. In the absence of exposure monitoring data, if sufficient evidence exists to demonstrate a potential for exposure above an OSHA action level, the employee shall be provisionally included in the medical surveillance program.
Each affected department must identify the employees who qualify for medical monitoring based upon job requirements and inclusion in specific occupational safety and health program (e.g., asbestos respirator use, noise exposure, hazardous materials, etc.) and identify the facilities where the employee work. Some requirements of the program follow:
a. Employees must complete the appropriate medical
work/history form prior to reporting to the designated medical facility. This form is available in the Safety Office.
b. The medical examination shall be performed by a
licensed occupational health professional at no cost and without loss of pay to the employee.
c. Medical exams and results of the exam will be
provided to the employee in a timely manner.
d. Employees shall be given an exam upon termination
of employment or removal from job activities which warranted inclusion in the program.
3.2. MEDICAL EXAMINATION REQUIREMENTS.
a. Frequency of medical examinations. The
frequency of medical examinations should be performed according to the following criteria:
1. Prior to a job assignment where medical surveillance is required.
2. Re-examination frequency as mandated by specific program, at least once every 12 months, or more frequently as deemed necessary by the attending physician.
3. Upon termination of employment or when the employee is reassigned to a new area/job classification not requiring medical surveillance (when the employee has not been examined within the previous 6 months), or when the employee’s work practices or environmental conditions change and there is no longer an exposure to the hazardous environment that required inclusion in the program.
4. As soon as possible upon notification that the employee has developed signs or symptoms indicating a possible exposure to a hazardous substance, or the employee has been injured or been exposed to an environment above the Permissible Exposure Limit (PEL) in an emergency situation.
b. Medical Examination Content. The medical exam
should include a past health and work history of the employee with emphasis on symptoms and signs related to exposure to a hazardous substance, the employee’s physical fitness related to the job classification, and the ability to wear personal protective equipment
(PPE) anticipated to be used in the workplace. The employer must supply the physician with the following:
1. Copy of the medical questionnaire.
2. Copy of the applicable Federal standard and appendices which will include mandatory clinical examination/test requirements.
3. Description of the employee’s duties pertaining to exposures.
4. Employee’s exposure or expected exposure levels, types of chemicals used or anticipated to be used should be provided.
5. Description of any PPE used.
6. Necessary information from previous medical exams.
The physician shall provide the employer (who will in turn provide the employee) a written opinion of the employee’s medical condition pertaining to the job classification, recommended limitations, the results of any medical testing, if so requested by the employee, and a statement that the employee has been informed of the medical exam findings. The written opinion obtained by the employer shall not reveal specific findings or diagnoses unrelated to occupational exposures.
3.3. MEDICAL RECORDKEEPING.
All employee medical surveillance records required by this section shall be preserved and maintained for the duration of the employee’s employment plus 30 years, as required by 29 CFR 1910.1020 (OSHA), Access to Employees Exposure and Medical Records. The medical records for employees who have worked less than 1 year for the employer, need not be kept past the duration of employment if the records are provided to the employee upon termination.
Employee exposure records contain information regarding the level of an employee’s exposure to potentially hazardous agents. These records are to be maintained in a confidential and secure manner by the Safety Office, and in the employee’s medical record, when required. Records must be made available to the employee upon request as required by 29 CFR 1910.1020.
.
4. PURPOSE.
CHAPTER 4. INDUSTRIAL HYGIENE PROGRAM
4. PURPOSE.
The Industrial Hygiene Program entails the anticipation, recognition and evaluation of physical, chemical, and biological hazards in the workplace and to provide for their reduction or elimination. Periodic field evaluations are conducted to assure the effectiveness of implemented controls. Any new/modified process, material or control change shall be re-evaluated. Industrial hygiene exposure assessment and sampling data will then be utilized for determination of employee inclusion in a medical surveillance program for hazards identified. The full resources of the Industrial Hygiene Program are available to tenant organizations of the Center through applicable Service Level Agreements (SLAs).
4.1. INDUSTRIAL HYGIENE SURVEYS AND HAZARD ASSESSMENTS.
a. Industrial Hygiene Surveys. Industrial Hygiene
field surveys are conducted in order to gather the following information:
1. Descriptions of operations and work practices, layout sketches of the work environment, and the time course of events.
2. Identification of hazardous materials that are currently in use or may be brought into the workplace that present a significant risk.
3. Identification of physical hazards.
4. Description of existing controls and an evaluation of their effectiveness.
5. Identification of personnel assigned to specific operations.
6. Identification of operations that require quantification of health hazards and subsequent sampling/monitoring.
b. Hazard Assessments. Based on the information
obtained during the industrial hygiene field survey, the next step is to assess whether or not there is a recognized potential hazard for employee exposure to toxic chemicals, physical hazards, or biological hazards. A hazard assessment shall be made by a technically qualified safety personnel and a written record maintained for each workplace where
chemical, physical, and\or biological hazards may be found. Rationale should be documented for any negative determinations.
4.2. WORKPLACE MONITORING.
If the hazard assessment indicates that an employee is exposed above the action level and or permissible exposure limit (PEL) to toxic chemicals and/or harmful physical or biological agents, workplace monitoring shall be prepared and implemented. The frequency of monitoring shall be in accordance with Federal Occupational Safety and Health Administration (OSHA) standards, the American Conference of Governmental Industrial Hygienist (ACGIH), or the professional judgment of the technically qualified safety personnel where no standards exist. Sampling and analysis of contaminants shall be in accordance with the National Institute of Occupational Safety and Health (NIOSH) Manual of Analytical Methods. Where no relevant NIOSH method exists, standard industry practices shall be employed to ensure the full evaluation of all hazards. Any laboratory assigned to analyze the samples shall be accredited by the American Industrial Hygiene Association (AIHA). All samples collected at the Center and sent for off-site analysis shall be recorded in a sample log book (electronic or hard copy) detailing the following minimum information: sample number, location, media, analyte(s) being tested and the name of the technically qualified safety personnel who collected the sample.
4.3. EQUIPMENT.
The maintenance and calibration of industrial hygiene equipment is critical to ensure that precise and accurate measurements of the workplace are made. Determination of any given employee’s actual exposure is a difficult task. Minimizing errors and approximating employee’s exposures makes it necessary to have a comprehensive calibration program in addition to professional experience, sound sampling strategies, and established analytical procedures.
The technically qualified safety personnel utilizing the equipment is responsible for ensuring the equipment has been field calibrated prior to use. A record of field calibration or verification must be kept by the Safety Office. Most equipment requires periodic manufacturer’s calibration. Any equipment that is not maintained in accordance with manufacturer’s recommendations must be marked “Out Of Service” until the equipment is either serviced or excessed. Examples of acceptable
4. PURPOSE. › 4.4. RECORDKEEPING.
laboratories for calibration would be; those recommended by the manufacturer, those with a demonstrated ability to calibrate a specific piece of equipment and, those with a quality control program such as traceability to the National Institute of Standards and Technology (NIST) or other equivalent system. Frequency of equipment calibration shall be that which is recommended by the manufacturer or more frequently as needed.
4.4. RECORDKEEPING. The compilation and interpretation of information collected during workplace surveys, subsequent hazard assessments, and quantification shall be accurately documented and maintained. This documentation provides employees with an assessment of the occupational health hazards in their work areas and provides recommendations for engineering, administrative controls, and personal protective equipment, as well as determining hazard based medical surveillance requirements of exposed personnel. Employees for whom personnel sampling is conducted shall be notified in writing of the results of any monitoring within 15 working days of receipt of the laboratory report. Industrial hygiene sampling data, including chain of custody and hard copy laboratory report, shall be filed in the Safety Office and maintained for a minimum of 30 years. Sampling data should be included in employee medical records.
5. PURPOSE.
CHAPTER 5. RESPIRATORY PROTECTION PROGRAM
5. PURPOSE.
It is the policy of the William J. Hughes Technical Center to provide employees with a safe and healthful working environment by utilizing facilities and equipment that have all feasible safeguards incorporated into their design. When effective engineering controls are not feasible, or while they are being implemented, respiratory protection shall be used.
5.1. MEDICAL EVALUATION.
A Physician or other Licensed Healthcare Professional (PLHCP) initially will make a determination as to whether or not an employee can wear the required respiratory protection without physical or psychological risk. The Safety Office will provide the PLHCP with information on the type of respirator to be used by the employee, and the frequency, duration and conditions of use. If a medical restriction is applied, the employee, the supervisor, and the Safety Office are to be formally notified of the restriction. Written documentation provided by the PLHCP will determine the status of medical qualification for respirator use. Medical tests and procedures will be conducted in accordance with OSHA medical surveillance requirements in 1910.134 (e) Medical Evaluation. Prior to the medical evaluation by the PLHCP, employees will complete the mandatory OSHA Medical Evaluation Questionnaire from Appendix C of the OSHA standard 1910.134. This form is obtained from the Safety Office. It is a confidential questionnaire reviewed only by the PLHCP.
5.2. SELECTION AND USE OF RESPIRATORY PROTECTIVE DEVICES.
a. Respirator Use. Personnel working under the
following conditions will be authorized to wear respirators:
1. Workers in areas known to have contaminant levels above the permissible exposure limits, or in which contaminants may exceed the permissible limits without warning.
2. Workers performing operations documented to pose health hazards, and those workers unavoidably required to be in the immediate vicinity where similar levels of contaminants are generated.
3. Workers in suspect areas, or performing operations suspected of generating health hazards, but for which adequate sampling data has not been obtained.
b. Respirator Selection. Selection of the proper
respirator to be used in any work area or operation at the William J. Hughes Technical Center is made only after it has been determined that there is an exposure to employees from contaminants that exceed the permissible exposure limit. This evaluation will be performed prior to the start of any routine or non-routine tasks requiring respirators. Respiratory protective devices will be selected by the Safety Office, using ANSI Z88.2 “Respirator Protection,” NIOSH Certified Equipment List, the NIOSH Respirator Selection Decision Logic, and/or MSDS’s, if appropriate information is provided. The following items will be considered in the selection of respirators:
1. Estimated maximum concentration of the substance in the work area.
2. Effectiveness of the device against the substance of concern.
3. General environment.
4. Known limitations of the respiratory protective device where concentration of contaminant is unknown or unobtainable.
5. Comfort, fit, and worker acceptance.
6. Other contaminants in the environment or potential for oxygen deficiency. Supervisors shall contact the Safety Office prior to nonroutine work that may expose workers to hazardous substances or oxygen deficient atmospheres. Examples of work that may require respiratory protection includes, but are not limited to:
(a) Asbestos abatement activities.
(b) Abrasive blasting.
(c) Cutting or melting lead, or stripping lead-
based paints from surfaces.
(d) Welding or burning.
(e) Painting, especially with epoxy or organic
solvent coatings.
(f) Using solvents, thinners, or degreasers.
(g) Any work which generates large amounts
of particulate (dusts, mists, fumes, smoke).
(h) Working in a confined or poorly ventilated
areas.
A review of operations requiring respirators will be made at least annually to determine if respiratory protection continues to be required, and if the previously chosen respirators still provide adequate protection.
c. Types of Respirators.
1. Air-Purifying Respirator (APR). These respirators remove air contaminants by filtering, absorbing, adsorbing, or chemical reaction with the contaminants as they pass through a cartridge attached to the respirator. The air-purifying respirator is to be used only where adequate oxygen (19.5 to 23.5 percent by volume) is available. Air-purifying respirators are not certified for use in immediately dangerous to life or health atmospheres (IDLH).
2. Atmosphere-supplying Respirators. These respirators provide breathing air from a source independent of the ambient atmosphere. Such respirators are to be used when the contaminant has insufficient odor, taste, or irritating warning properties, or when the contaminant is of such high concentration or toxicity that an air-purifying respirator is inadequate.
(a) Methods of Breathing Air Regulation.
Breathing air may be regulated by the atmosphere-supplying respirator by the following methods:
(1) Demand. This respirator supplies air
to the user on demand (inhalation) when a negative pressure is created inside the facepiece. Leakage into the facepiece can occur if there is a poor seal between the respirator and the user's face.
(2) Pressure-Demand. This respirator
maintains positive pressure inside the facepiece , and admits breathing air
when the positive pressure is reduced inside the facepiece by inhalation.
(3) Continuous Flow. This respirator
maintains a continuous flow of air through the facepiece at all times, rather than only on demand.
(b) Common Types of Atmosphere-supplying
Respirators:
(1) Supplied-air Respirator (SAR) or
Airline Respirator. The source of breathing air for this respirator is not designed to be carried by the user, and may be provided by a compressed breathing air cylinder or air compressor designed to provide breathing air. Airline respirators may be demand, pressure-demand, or continuous flow.
(2) Self-Contained Breathing Apparatus
(SCBA). The breathing air source is designed to be carried by the user, allowing the user complete independence from a fixed source of air. Training and practice in its use and maintenance is essential. This type of device will be used in emergency situations, oxygen deficient atmospheres, IDLH atmospheres or unknown concentration of contaminants present in the area. This device should only be filled with type 1 Grade D breathing air. SCBA’s should never be filled with oxygen. SCBA may be demand or pressuredemand units. Pressure-demand is the most common type of SCBA.
d. Identification of Respirator Cartridges. Respirator
cartridges are designed to protect against individual or a combination of potentially hazardous atmospheric contaminants, and are specifically labeled and color coded to indicate the type and nature of protection they provide. (See Figure 1, Air Purifying Respirator, Chemical Cartridge Types).
The NIOSH approval label on the respirator will also specify the maximum concentration of contaminant(s) for which the cartridge is approved.
The most commonly used air-purifying respirator cartridges can be classified as follows:
1. Particulate removing filter out dusts, fibers,
fumes, and mists.
2. Gas and vapor-removing these devices remove specific organic vapor and acid gas contaminants listed in the manufacturer’s literature. Contaminants are removed by absorption, adsorption, or by chemical reaction. Separate cartridges are available for organic vapors and acid gases, or in combination as one cartridge.
3. Combination particulate/gas and vapor removing respirators combine the removal characteristics of all three types of cartridges, organic vapor, acid gas, and particulate.
e. Warning Signs of Respirator Failure.
1. Particulate Air-Purifying. When breathing difficulty is encountered with a filter respirator (due to partial clogging with increased resistance), the filter must be replaced.
2. Gas or Vapor Air-Purifying. If, when using a gas or vapor respirator (chemical cartridge or canister), any of the warning properties (e.g., odor, taste, eye irritation, or respiratory irritation) occur, promptly leave the area and check the following:
(a) Proper face seal.
(b) Damaged or missing respirator parts.
(c) Saturated or inappropriate cartridge or
canister.
If no discrepancies are observed, replace the cartridge or canister. If any of the warning properties appear again, the concentration of the contaminants may have exceeded the design specification.
f. End of Service Life and Change Schedules for Air-
Purifying Respirator Canisters and Cartridges . The canisters or cartridges of air-purifying respirators are at the end of their service life when filter resistance precludes further use, or the chemical sorbent is expended as signified by a specific warning property, e.g., odor, taste, or cartridge indicator etc. To ensure that canisters and cartridges are changed before the end of their service life, employees will follow the Change Schedule in the FAA Technical Center Respiratory Protection Program. New canisters, cartridges, or filters shall always be provided as needed.
g. Cartridge Change-Out Schedules. For those
organic vapor air purifying cartridges used that do not have an end-of-life-indicator, a schedule of cartridge change-out has been established and can be found in the standard operating procedures developed for each specific work area as applicable.
h. Supplied Air Respirator. When using an airline
respirator, leave the area immediately when the compressor failure alarm is activated or if an air pressure drop is sensed. When using an SCBA leave the area as soon as the low pressure alarm is activated.
5.3. RESPIRATOR TRAINING.
Respirator users and their supervisors will receive training on the contents of the Respiratory Protection Program and their responsibilities. The Safety Office will provide the initial and annual training only upon successful completion of the medical evaluation and fit-testing. The training program will include the following:
a. Nature and degree of respiratory hazard.
b. Respirator selection, based on the hazard, respirator
capabilities, and limitations.
c. Donning and doffing, positive and negative
pressure fit tests including hands-on practice.
d. Care of the respirator, e.g., cleaning, maintenance,
storage, and/or replacement.
e. Use and limitations of respirator.
5.4. RESPIRATOR FIT TESTING.
A fit test, conducted by the Safety Office, shall be used to determine the ability of each individual respirator wearer to obtain a satisfactory fit with any respirator with a negative or positive pressure tight-fitting facepiece. The test results will be the determining factor in selecting the type, model, and size of the respirator. The OSHA Respiratory Protection Standard, 1910.134, requires either quantitative or qualitative fit tests, and contains fit testing procedures in Appendix A. Personnel must successfully pass the fit test before being issued a respirator.
No FAA employee is permitted to wear a respirator in a work situation until he or she has demonstrated that an acceptable fit can be obtained. Respirator fitting will be conducted upon medical qualification, initially prior to task assignment requiring use of a respirator and annually thereafter.
a. Fit Checking. Each time a respirator is donned, the
user will perform positive and negative pressure fit
checks. These checks are not a substitute for fit testing. Respirator users must be properly trained in the performance of these checks and understand their limitations.
b. Negative Pressure Check.
1. Applicability/Limitations. This test cannot be carried out on all respirators; however, it can be used on facepieces of air purifying respirators equipped with tight-fitting respirator inlet covers, and on atmosphere supplying respirators equipped with breathing tubes which can be squeezed or blocked at the inlet to prevent the passage of air.
2. Procedure. Close off the inlet opening of the respirator's cartridge(s), or filter(s) with the palm of the hand, or block its inlet so that it will not allow the passage of air. Inhale gently and hold for at least 10 seconds. If the facepiece collapses slightly and no inward leakage of air into the facepiece is detected, it can be reasonably assumed that the respirator has been properly positioned and the exhalation valve and facepiece are not leaking.
c. Positive Pressure Check.
1. Applicability/Limitations: This test cannot be carried out on all respirators; however, respirators equipped with exhalation valves can be tested.
2. Procedure: Close off the exhalation valve with the palm of the hand. Exhale gently. If the respirator has been properly positioned, a slight positive pressure will build up inside the facepiece without detection of any outward air leak between the sealing surface of the facepiece and the face.
5.5. QUALITATIVE FIT TESTING
The qualitative fit test checks the subject's response to a chemical introduced outside the respirator facepiece.
This response is either voluntary or involuntary depending on the chemical used. The two most common are the irritant smoke test, and the odorous vapor test.
a. Irritant Smoke. The irritant smoke test is an
involuntary response test. Air-purifying respirators must be equipped with a high efficiency particulate air (HEPA) filter for this test. An irritant smoke is directed from a smoke tube toward the respirator. If the test subject does not respond to the irritant smoke, it is assumed that a satisfactory fit has been
achieved. Any response to the smoke indicates an unsatisfactory fit.
b. Odorous Vapor. The odorous vapor test is a
voluntary response test. It relies on the employee’s ability to detect an odorous chemical while wearing the respirator. Air purifying respirators must be equipped with an organic cartridge or canister for this test. Isoamyl acetate (banana oil) is the recognized and standard method. An isoamyl acetate ampuole is placed near the facepiece-toface seal of the respirator. If the employee is unable to smell the chemical, then it is assumed that a satisfactory fit has been achieved. If the employee smells the chemical, the fit is unsatisfactory. If the employee cannot smell the chemical, the respirator will be momentarily pulled away from the employee’s face, and if they are then able to smell the chemical, a satisfactory fit is assumed. If the employee is unable to smell the chemical without the respirator, this test is inappropriate, and a different test will be used. This test is limited by the wide variation of odor thresholds among individuals and the possibility of olfactory fatigue. Since it is a voluntary response test it depends upon an honest response.
5.6. QUANTITATIVE FIT TESTING.
Quantitative fit testing is generally performed on both full-face and half-face negative pressure respirators and positive pressure respirators with tight-fitting masks. Fit factors are determined by comparing the particle concentration outside the respirator with the concentration inside the respirator facepiece. An acceptable fit is achieved when the respirator wearer successfully completes a series of programmed exercises (normal breathing, deep breathing, moving head up and down, moving head side to side, reading, bending and touching the toes and normal breathing) with a fit factor of at least 100 for the half face respirator and a fit factor of at least 500 for the full face respirator.
5.7. SPECIAL PROBLEMS.
a. Facial Hair. No attempt will be made to conduct a
fit test on an employee who has facial hair which comes between the sealing periphery of the facepiece and the face, or if facial hair interferes with normal functioning of the exhalation valve of the respirator.
b. Glasses and Eye/Face Protective Devices. Proper
fitting of a respirator facepiece for individuals wearing corrective eyeglasses may not be
established if temple bars or straps extend through the sealing edge of the facepiece. If eyeglasses, goggles, face shield, or welding helmet must be worn with a respirator, they must be worn so as not to adversely affect the seal of the facepiece. If a full-facepiece respirator is used, special prescription glasses inserts are available.
5.8. MAINTENANCE AND ISSUANCE OF RESPIRATORS.
a. Maintenance. The maintenance of respiratory
protective devices involves a thorough visual inspection for cleanliness and defects (i.e., cracking rubber, deterioration of straps, defective exhalation and inhalation valves, broken or cracked lenses, etc.). Worn or deteriorated parts will be replaced. No respirator with a known defect shall be issued for use. No attempt shall be made to replace components, make adjustments, or make repairs on any respirator beyond those recommended by the manufacturer. Under no circumstances will parts be substituted, as such substitutions will invalidate the approval of the respirator. Any repair to supplied air respirators or self-contained breathing apparatus, including valves, regulators, alarms, masks, or cylinders, will be conducted by a manufacturer certified technician.
b. Cleaning of Respirators. All respirators in routine
use shall be cleaned and sanitized on a periodic basis. Respirators used non-routinely shall be cleaned and sanitized after each use and filters and cartridges replaced. Maintenance of routinely used respirators is the responsibility of the wearer. Cleaning and disinfecting of respirators must be done frequently to ensure that skin-penetrating and dermatitis-causing contaminants are removed from the respirator surface. Respirators maintained for emergency use or those used by more than one person must be cleaned after each use by the user.
The following procedure is recommended for cleaning and disinfecting respirators:
1. Remove and discard all used filters and cartridges.
2. Wash facepiece in warm water with a mild detergent or a cleaner-disinfectant product made specifically for respirators. Solvents or alcohol shall not be used.
3. Rinse completely in clean, warm water.
4. Air dry in a clean area in such a way as to prevent distortion.
5. Clean other respirator parts as recommended by the manufacturer.
6. Inspect valves, headstraps, and other parts to ensure proper working condition.
7. Reassemble respirator and replace any defective parts.
8. Place in a clean, dry plastic bag or other suitable container for storage after each cleaning and disinfecting.
5.9. ISSUANCE OF RESPIRATORS.
Respiratory protective equipment shall not be ordered, purchased, or issued to personnel unless the respirator wearer has received a medical evaluation, respirator training and a fit test. New employees who require respiratory protective equipment must be placed into the respirator program before being issued equipment.
Disposable paper dust masks or comfort masks are not a recognized form of respiratory protection and shall not be issued for use at any time on William J. Hughes Technical Center controlled premises.
5.10. STORAGE.
After inspection, cleaning, and any necessary minor repairs, store respirators to protect against sunlight, heat, extreme cold, excessive moisture, damaging chemicals, or other contaminants. Respirators placed at stations and work areas for emergency use shall be stored in compartments or covers clearly marked as emergency equipment, and shall be quickly accessible at all times. Routinely used respirators, such as half-mask or full-face air-purifying respirators, shall be placed in sealable plastic bags. Respirators may be stored in such places as lockers or toolboxes only if they are first placed in carrying cases or cartons. Respirators shall be packed or stored so that the facepiece and exhalation valves will rest in a normal position and not be crushed.
5.11. PROGRAM EVALUATION.
An appraisal of the effectiveness of the Respiratory Protection Program shall be carried out as necessary to ensure that the provisions of the written program are being effectively implemented. The evaluation will include investigating wearer acceptance of respirators, inspecting respirator program operation, and appraising protection provided by the respirator. The findings of the program evaluation will be documented, and this documentation will contain the revisions and changes needed to ensure continued effectiveness of the program, and set target dates for the implementation of any action items.
5.12. RECORDKEEPING.
Respirator fit-testing shall be documented and shall include the type of respirator, brand name and model, method of test and test results, test date, and the name of the instructor/tester. The medical clearance form will be kept with the employee’s medical records by the Physician or Other Licensed Health Care Professional (PLHCP) providing the medical exams for FAA, and a copy of the form will be given to the employee. The training logs, program roster, and fit-test records will be maintained by the Safety Office.
5.13. CONTRACTORS
Contractors are responsible for providing their own respiratory protection programs and respiratory protective equipment, unless otherwise stated in the contract that the FAA will provide safety- related personal protective equipment. They are required to develop and implement a respiratory protection program for their employees who must enter into or work in areas where exposure to hazardous materials cannot be controlled or avoided. This program must meet OSHA regulations and include issuance of respirators, medical evaluations, fit testing, and training.
5.14. VOLUNTARY USE OF RESPIRATORS
If employees choose to use respiratory protection voluntarily, the requirements of 29 CFR 1910.134 (c ) apply. This includes the following:
a. Ensuring that the employee is medically qualified
by a PLHCP to wear the respirator.
b. Providing the employee with information contained
in 29 CFR 1910.134, Appendix D.
c. Ensuring that the respirator is cleaned, stored, and
maintained so that it does not present a health hazard to the employee.
d. Maintaining a completed copy of the Voluntary
Respirator User Form for each employee/contractor voluntarily using a respirator. These forms can be obtained from the safety office Respiratory Protection Program Manager.
CHAPTER 6. HEARING CONSERVATION PROGRAM
6. PURPOSE.
The primary goal of the Hearing Conservation Program is to prevent hearing loss due to exposure to noise in the workplace. The program establishes requirements based on the Occupational Safety and Health Administration (OSHA) standard, 29 CFR 1910.95, Occupational Noise Exposure, and includes the following elements:
6. PURPOSE. › 6.1. NOISE EVALUATION AND SURVEILLANCE PROCEDURES.
a. Surveillance and monitoring of the work
environment to identify potentially hazardous noise levels and personnel at risk.
b. Implementation of engineering controls wherever it
is technologically and economically feasible to reduce noise levels to acceptable limits.
c. Implementation of administrative controls and/or
the use of hearing protective devices where engineering controls are not feasible.
d. Annual audiometric testing of personnel to monitor
the effectiveness of the hearing conservation program. Early detection of temporary threshold shifts will allow further protective action to be taken before permanent hearing loss occurs.
e. Training and education of personnel in the
elements of the hearing conservation program to include: the nature of noise-induced hearing loss, the employee's responsibilities under the program, and proper use and maintenance of hearing protective devices.
6.1. NOISE EVALUATION AND SURVEILLANCE PROCEDURES.
a. Identification of Hazardous Noise Areas. The
Safety Office will identify work areas within William J. Hughes Technical Center facilities where noise levels equal or exceed an 85 dBA action level, based on an 8 hour time-weighted average. Records shall be maintained by the Safety Office and updated regularly to document any alteration in noise levels as a result of new equipment or process change. Those areas where the noise levels are below 85 dBA will not be routinely monitored. Identification of hazardous noise areas and equipment and any subsequent noise monitoring will be conducted by the Safety Office.
Signs will be posted at the entrance to any work area where noise levels exceed 85 dBA, requiring anyone entering the area to wear proper hearing protection. Personnel who work in these areas shall have hearing protection supplied to them, shall be instructed in its proper use, and be required to wear this equipment when in these areas. It is the responsibility of the area supervisor to ensure that these precautions are enforced. Equipment which produces noise levels greater than 85 dBA, or 140 dB peak sound pressure levels, shall also be appropriately labeled.
b. Noise Measurements and Exposure Assessments.
In order to effectively control noise it is necessary that the noise be accurately measured according to standard procedures and that the measurements be properly evaluated against accepted criteria. The 8 hour time-weighted average noise exposure will be determined according to OSHA 1910.95 Appendix A, Noise Exposure Computation, and compared to Table G-16, Permissible Noise Exposure The monitoring of employees for noise exposure is made up of two parts, area and personal monitoring. Area measurements are generally obtained first. If noise levels are at or above the 85 dBA action level, personal noise dosimeters shall then be utilized to determine 8-hour time-weighted average exposure levels. All noise exposure monitoring data will be recorded and maintained.
c. Area Measurements. In an area survey,
measurements of environmental noise levels are recorded using a sound-level meter to identify work areas where employees' exposures may be above hazardous levels. Area monitoring is conducted using a calibrated sound level meter set to the “A” scale, slow response. Within the area of interest, several different locations will be measured. Typical measurement locations would include:
1. In the hearing zone at the employee's work location.
2. Adjacent to the noise source(s).
3. At the entrance(s) to the work area.
6. PURPOSE. › 6.2. NOISE CONTROL METHODS.
4. At other locations within the area where the employee might spend time.
A detailed diagram of the area will be included with the results indicating the locations where the noise readings were obtained. If the noise levels are below 85 dBA on an 8-hour time-weighted average basis in the area, no additional noise monitoring will be required for that area. Should any of the noise measurements equal or exceed 85 dBA, records shall be maintained as to the noise levels recorded, where they were taken, and the source(s) of the noise. These records shall be updated regularly to determine if any changes have occurred that would warrant additional monitoring of exposed personnel.
d. Personal Monitoring. If initial measurements
indicate a potential for an 8 hour time-weighted average exposure at or above 85 dBA, a determination of the actual noise exposure will be accomplished using calibrated personal noise dosimeters. A noise dosimeter will be placed on the employee at the beginning of the work shift, with the microphone placed in the hearing zone, usually on the lapel or shoulder. The dosimeter will be worn for the full duration of the work shift. At the end of the work shift, the dosimeter will be removed and exposure data recorded. Background information will be collected from each employee detailing job description, unusual job activities, potential interferences, etc., for the time period sampled. Those employees whose noise exposure equals or exceeds 85 dBA on an 8-hour TWA will be referred for inclusion in the Hearing Conservation Medical Surveillance Program.
e. Repeat Monitoring of Hazardous Noise Areas.
Any area with noise levels that equal or exceed 85 dBA shall be re-monitored whenever a change in production, process, equipment, or controls increase the noise exposure such that 1) additional employees may be exposed to noise levels at or above the 85 dBA action level on a time-weighted average basis, or 2) the attenuation provided by the hearing protectors used by employees may be inadequate. Areas where the noise levels have dropped below 85 dBA shall be eliminated from the monitoring program.
6.2. NOISE CONTROL METHODS.
a. Engineering Controls. The primary means of
reducing or eliminating exposure to hazardous noise is through the application of engineering controls defined as any modification or
replacement of equipment, or related physical change at the noise source or along the transmission path that reduces the noise level at the employee's ear. Engineering controls shall be utilized where feasible to minimize exposure to hazardous noise levels. Consideration of noise exposures shall be made as early as possible in the procurement, design or modification of equipment.
b. Administrative Controls. Where the highest rated
hearing protective equipment, engineering controls, or combination of both are not sufficient to attenuate noise exposure to less than 90 dBA TWA, an employee’s duration of time spent in the noise hazard area shall be limited so as not to exceed the default maximum exposure limit of 90 dBA TWA.
For employees who have demonstrated a persistent Standard Threshold Shift, this exposure limit is reduced to 85 dBA TWA in accordance with 29 CFR 1910.95.
c. Hearing Protective Devices. Hearing-protective
devices shall be the permanent solution only when engineering or administrative controls are considered to be infeasible, or fail to adequately reduce noise. Hearing-protective devices are earmuffs or earplugs that can be worn to reduce the level of sound entering the ear. Hearing protective devices shall be worn by all personnel when they must enter or work in an area where the operations generate noise levels of 85 dBA or greater.
1. Types of Hearing Protective Devices (HPDs). Some types of hearing protective devices include the following:
(a) Insert Type Earplugs. A device designed
to seal the ear canal without being uncomfortable. Insert earplugs include the following:
(1) Pre-molded earplugs are pliable
devices of fixed proportions. Two standard styles are the single flange and triple flange. Pre-molded plugs may come in one size or in various sizes. With pre-molded plugs, a person may need a different size plug for each ear. Pre-molded earplugs are reusable and washable. They should be replaced periodically when they show signs of distortion or deterioration, or when a sealed fit cannot be obtained in the ear canal.
(2) Expandable or Formable earplugs
come in just one size. They are made of material that, after being compressed and inserted, expands to conform to the shape of the ear canal. When properly inserted, they provide noise attenuation values that are similar to or exceed those from correctly fitted pre-molded earplugs. Each earplug must be held in place while it expands enough to remain firmly seated. These earplugs may be reusable and washable, but should be replaced frequently, or when they no longer seal the ear canal when properly inserted.
(b) Earmuffs. Earmuffs are devices that
completely cover the outer ear to reduce the level of noise that reaches the ear. Their effectiveness depends on a seal between the cushion and the head. Hair, sideburns or temples of glasses can break the seal around the ear, and earplugs should be used.
2. Selection of Hearing Protective Devices. Employees will be given the opportunity to select hearing protective devices from a variety of suitable devices approved by the Safety Office. In all cases the chosen hearing protectors shall have a Noise Reduction Ratio (NRR) high enough to reduce the noise at the eardrum to below 85dBA.
3. Issuance of Hearing Protective Devices. The issuance of hearing-protective devices is coordinated through the Safety Office. Instruction on the proper use and care of earplugs and earmuffs will be provided whenever HPDs are dispensed. Personnel requiring earmuffs in addition to earplugs will be informed of this requirement and educated on the importance of using proper hearing protection.
4. Use of Hearing Protective Devices (HPD). Always use and maintain HPDs as originally intended and in accordance with instructions provided. Earmuff performance may be degraded by anything that compromises the cushion-to-skin seal. This includes other pieces of personal protective equipment such as eyewear, masks, faceshields, and helmets. HPDs shall be for the exclusive use of each employee.
5. Maintenance of Hearing Protective Devices. Reusable earplugs, such as the triple flange or
formable devices, should be washed in lukewarm water using hand soap, rinsed in clean water, and dried thoroughly before use. Wet or damp earplugs should not be placed in their containers. Cleaning should be performed as needed.
Earmuff cushions should be kept clean. The plastic or foam cushions may be cleaned in the same way as earplugs, but do not allow the inside of the muff to get wet. Allow cushions to completely dry before storing.
d. Hearing Protection Performance Information.
HPDs shall attenuate noise exposure at the ear to a level of 85 dBA-TWA or below, based on the Noise Reduction Rating (NRR) of the protector. Estimation of the adequacy of hearing protector attenuation shall be performed according to OSHA-specified methods in 1910.95, Appendix B, “Methods for Estimating the Adequacy of Hearing Protector Attenuation.”
An HPD may have a high Noise Reduction Rating, but without properly fitted HPDs, the actual noise reduction may be less because the noise may bypass the hearing-protective device and be transmitted through tissue and bone pathways to the inner ear.
The term "double hearing protection" is misleading. The attenuation provided from any combination earplug and earmuff is not equal to the sum of their individual attenuation values. The Hearing Conservation Program shall emphasize proper use and care of HPDs as a means of reducing noise exposure, rather than reliance on the NRR. Employee training shall included proper interpretation of the NRR, and the need for safety factors when estimating noise attenuation.
6.3. MEDICAL SURVEILLANCE.
a. Notification. Upon identification of employees
whose 8-hour TWA equals or exceeds 85 dBA, the Safety Office will enroll them in the Hearing Conservation Program. Information will include the employee’s name, supervisor's name, telephone number, and the noise levels recorded in the employee's work area, including any dosimetry data.
In work locations where either through administrative or engineering controls, noise levels are found to have decreased such that the employee's 8-hour TWA is below 85 dBA, those employees will no longer be enrolled in the
Hearing Conservation Program.
b. Audiometric Testing. All employees enrolled in the
Hearing Conservation Program shall receive audiometric testing. Audiometric testing will be provided by a board certified occupational physician or certified audiometric technician under the direction of the physician, and shall include baseline and annual audiometry. The audiometric testing program shall adhere to the requirements outlined in 29 CFR 1910.95 (g) and (h), and Appendices C, D and E.
Where feasible, baseline audiograms shall be obtained prior to an employee’s first exposure to noise that equals or exceeds the action level. If not feasible, it shall be obtained as soon as possible, but no longer than 6 months after it becomes known that the employee is or will be exposed to noise that equals or exceeds the action level.
6.4. TRAINING.
The training and education program will provide information concerning the adverse effects of noise and how to prevent noise-induced hearing loss. At a minimum, all training will cover the following topics:
a. Noise-induced hearing loss.
b. Recognizing hazardous noise.
c. Symptoms of overexposure to hazardous noise.
d. Hearing protection devices--advantages and
limitations.
e. Selection, fitting, use, and maintenance of hearing
protective devices.
f. Advantages, disadvantages and attenuation of
HPDs.g.
g. Engineering and administrative control measures.
h. Explanation of noise measurement procedures.
i. Hearing conservation program requirements.
j. Audiometric testing purpose, requirements and test
procedures.
Supervisors must contact the Safety Office to schedule training for new personnel assigned to work in hazardous noise environments and for retraining of current personnel.
6.5. PROGRAM EVALUATION.
Periodic program evaluations will be conducted to assess compliance with OSHA regulations and FAA program requirements. Both noise exposure monitoring and audiometric testing portions of the Hearing Conservation Program will be reviewed annually to assure its quality and effectiveness.
An evaluation of the Program, including wearer acceptance, appraisal of protection afforded, and field audits of hearing protection use and record keeping will be conducted at least annually. Items to be considered include:
a. Standard operating procedures.
b. Training records and course content for supervisors
and employees.
c. Maintenance of HPDs.
d. Field audits of HPD use.
e. Review of recorded threshold shifts on OSHA log.
The findings of the Hearing Conservation Program evaluation will be documented, and this documentation will list plans to correct faults in the program and set target dates for the implementation of the plans.
6.6. RECORDKEEPING.
Hearing Conservation Program will include the following:
a. All non-medical records will be maintained for a
period of 5 years. Results of hearing tests and medical evaluations performed for hearing conservation purposes as well as noise exposure documentation shall be recorded and shall be a permanent part of an employee's health record.
b. All personnel who routinely work in designated
hazardous noise areas shall be identified and a current roster of such personnel shall be maintained by the Safety Office and updated periodically.
6.7 OTHER DOCUMENTS
FAA WM J. Hughes Technical Center, Environmental Branch, Safety Office, Hearing Conservation Program.
FAA Occupational Safety and Health Program, Order 3900.19B, Chapter 21, Hearing Conservation Program.
7. PURPOSE. › 7.1. HAZARD IDENTIFICATION/ANALYSIS.
CHAPTER 7. ERGONOMICS PROGRAM
7. PURPOSE.
Ergonomics is the science of fitting workplace conditions and job demands to the capabilities of workers. The William J. Hughes Technical Center seeks to provide a safe and healthful work environment through the application of ergonomic principles in the identification, evaluation, and control of ergonomic problems. Ergonomic problems arise from a combination of conditions and risk factors: activities that present biomechanical stress to the body (e.g. repetitive motion); poorly designed equipment, work flow or workstation; improper work practices or techniques; insufficient rest/recovery periods, physical condition, and other such factors that may result in musculskeletal disorders (MSDs). Ergonomically-related MSDs usually reflect a gradual or chronic development, and include cumulative trauma disorders such as carpal tunnel syndrome, tendonitis, and low back pain. Both work-related and nonwork related activities and conditions may individually, or by interacting with each other, give rise to MSDs. Risk factors in the workplace that may contribute or cause ergonomic-related injuries include repetitive, forceful or prolonged exertions; prolonged static positions or awkward postures; frequent or heavy lifting, pushing, pulling or carrying of heavy objects; and vibration from tools or equipment.
The goal of the ergonomics program is to evaluate and design the environment, workstations, and equipment to complement the capabilities of employees, and prevent the potential for fatigue, operator error, accidents, and cumulative trauma disorders.
7.1. HAZARD IDENTIFICATION/ANALYSIS. Ergonomic risk identification at the William J. Hughes Technical Center will consist of the evaluation of workplace injuries and illnesses for identification of trends, the results of worksite ergonomic analyses, and employee concerns. When a workstation, task or operation has been identified for ergonomic analysis, the following methods may be used to determine potential problems, and the corrections needed to control or prevent injury or illness: directly observing the job performance; interviewing employees; workstation measurements; and video monitoring the job performance. Results of the analysis will be documented to provide necessary data for implementing control measures.
Workstations should be evaluated for risk factors.
Checklists for evaluation of ergonomic risk factors in the workplace are available from the Safety Office. If the workstation contains one or more of these risk factors, ergonomic principles and control measures should be applied (e.g. proper work practices, design correction or modification, work flow adjustment, work/rest regimen):
a. Repetition - Repeating the same motion or motion
pattern every few seconds or using the keyboard or mouse steadily for several hours per day.
b. Awkward Positions - Raising or working with the
hands above the head for prolonged periods of time.
c. Vibration - Tools or equipment that produce
vibration.
d. Contact Stress - Frequent or repetitive pressure on
the body (e.g., hand, finger, forearm, foot, knee) by a hard or sharp object, e.g. using the hand like a hammer, prolonged kneeling, unpadded tools, levers or handles requiring force.
e. Force - Lifting, pushing or pulling heavy objects
f. Prolonged static postures - Holding of the body or
arms in a fixed position for an extended period of time with little or no movement.
g. Using inadequate tools for the required job.
h. Inadequate seating or seat support.
i. Improper lighting.
7.2. HAZARD PREVENTION AND CONTROL
The results of an ergonomic analysis will be used to implement engineering controls and reduce or eliminate ergonomic risk factors. Some engineering controls include: redesign or modification of the workstation, work method, or tool to reduce stress. Administrative controls may be needed in addition to engineering controls, and include such things as work/rest regimens and job rotation. Proper work practices and ergonomically correct movement is critical to preventing injury, and a key element of employee awareness and training. These techniques include proper lifting techniques, posture correction, work object/movement adjustments (positioning objects closer or lower to reduce reaching up or out), and corrective exercises (moving and stretching
7. PURPOSE. › 7.4. RECORDKEEPING
muscle sets in the opposite direction of the potentially harmful posture or movement). Training personnel to recognize ergonomic risk factors, to apply proper working techniques and exercises, and to recognize early warning signs of cumulative trauma disorders will assist in early detection and prevention of injury\illness. When plans are developed for new or modified facilities, processes, or equipment, ergonomic analysis should be performed.
a. Engineering Controls. The concept of ergonomic
design is to make the job, equipment or tool compatible with the person.
1. Proper egonomic design of a workstation should include the following:
(a) Reduction of static loading on muscles.
(b) Proper work surface height, with
adjustable features where necessary.
(c) Chair design which may include adjustable
heights, swivel, and back/lumbar support.
(d) Reducing reaching distances in front, to
the side, overhead, behind the back, far in front, or to the side of the worker.
(e) Padding work surfaces where employees
may contact or rest on hard edges.
(f) Workstation layout to facilitate the flow of
material and products through the station.
(g) Proper lighting to reduce eyestrain.
Inadequate lighting reduces the contrast between surfaces. Bright lighting causes excessive reflection off work surfaces. Video display terminals (VDT) should be positioned to reduce the glare from interior lights and sunlight, and increase the contrast of the images on the screen.
2. Tool Design. Improper hand tool selection and design may contribute to cumulative trauma disorders. Several factors should be considered when selecting a tool. Some of these factors include the following:
(a) Selecting the correct tool for the job and
using the tool in the proper manner.
(b) Minimizing vibration
(c) Selecting tools that are designed to reduce
excessive hand gripping to perform a job function.
(d) Selecting hand tools that do not have pre-
molded, form-fitting grips on the handle. These grips will fit only one size of hand.
b. Administrative Controls. Administrative controls
are applied to limit the duration, frequency, and severity of exposure to the risk factors related to cumulative trauma disorders. Administrative controls do not eliminate risk factors. Administrative controls are designed to allow for stressed and strained muscles and joints to rest and recover. Administrative controls include the following:
1. Employee rotation on a job containing risk factors.
2. Rest breaks.
3. Decrease production rates and limit overtime work.
4. Increasing the number of employees.
c. Personal Protective Equipment. Personal
Protective Equipment should be selected in conjunction with other controls, and not used in place of other controls. The equipment should be provided in a variety of sizes, and accommodate the physical requirements of the job and the employee.
7.3. TRAINING.
Training should be provided to personnel who are assigned to workstations or tasks involving ergonomic risk factors. The training should include but not be limited to the following topics:
a. How to identify ergonomic risk factors in the
workplace.
b. Signs and symptoms of musculoskeletal disorders
(MSDs).
c. Reporting procedures for MSD’s.
7.4. RECORDKEEPING Records shall be maintained for all workstation/work activity ergonomic analyses. All MSD injuries and illnesses shall be reported to the Safety Office immediately via the guidelines outlined in Chapter 30, Mishap Reporting and Reporting Unsafe or Unhealthful Conditions.
8. PURPOSE.
CHAPTER 8. INDOOR AIR QUALITY
8. PURPOSE. The indoor environment is a result of the interaction among many factors such as: the building’s location, climate, construction methods and materials, renovations, occupant activities, furnishings, and equipment. The goal of an indoor air quality (IAQ) program is to proactively anticipate and prevent conditions and/or building systems from contributing to a compromise of the quality of indoor air that may lead to or exacerbate adverse physiological conditions or discomfort among building occupants. Some parameters that can contribute to poor indoor air quality are: extremes of humidity and temperature, lack of outdoor air introduction, off-gassing of furnishings, equipment and construction materials, tobacco smoke, and biological contamination such as fungi, bacteria, and pollen which may be present in stagnant water, air ducts, humidifiers, and drain pans. The indoor air quality investigation serves to identify and abate building conditions contributing to compromised indoor air quality and to prevent similar situations or conditions from recurring. Further guidance for conducting an IAQ investigation can be found in the Indoor Environment Quality Investigator work instruction (FSED-WI-ENV-0130). Once IAQ concerns are filed or noted by building occupants, an IAQ investigation shall be conducted to identify the nature and severity of the observed IAQ conditions. The information collected during the initial investigation may dictate more advanced IAQ investigation methodologies.
8.1. DEFINITIONS.
a. ASHRAE. American Society of Heating,
Refrigeration and Air Conditioning Engineers. The consensus standard organization for heating, ventilating, and air conditioning (HVAC) design.
b. Biological Contaminants. Agents that are living or
derived from living organisms, such as fungi, bacteria, viruses, and animal antigens. Such biologicals can be inhaled and may cause allergic reactions, hypersensitivity, and respiratory irritation.
c. Building Related Illness (BRI). Illnesses for which
there is a clinically defined etiology and for which there may be confirming laboratory and physical evidence. Examples include legionella, psittacosis, and hypersensitivity pneumonitis.
d. Particulates. Particles, especially allergens and
irritants can be present in the air. Particulates may
serve as a core carrier for volatile organic compounds (VOCs) or other chemicals.
e. Sick Building Syndrome (SBS). A condition
associated with complaints of discomfort that may include headache, nausea, dizziness, dermatitis, upper respiratory irritation, cough, fatigue, eye irritation, and difficulty concentrating. Symptoms generally appear after spending some period of time in the workplace but lessen or disappear after leaving the work site.
f. Volatile Organic Compounds (VOCs). Refers
collectively to the organic vapors that contaminate indoor air emanating from building materials, cleaners, paints, adhesives, and solvents.
8.2. BUILDING DESIGN AND MAINTENANCE CONSIDERATIONS.
Many potential IAQ problems can be precluded by designing and constructing new or renovated buildings to meet the latest ASHRAE standards.
a. HVAC System Preventative Measures
1. Replace filters according to the HVAC System manufacturer’s recommendations or more frequently as needed. The efficiency of the air filters should be a minimum of 60 percent or that which is feasible for the HVAC system, as recommended by ASHRAE.
2. Draw a minimum of 20 cubic feet per minute (cfm) of outside air per person into the building through the HVAC system. This is necessary to control air contaminants and odors.
3. Ensure that the HVAC system supply and return air grill locations are properly spaced for the thorough mixing and distribution of conditioned supplied air throughout work area.
4. Perform an overall inspection of the HVAC system including the following:
(a) Verify that the system is properly balanced
and adequate air flow is being delivered.
(b) Ensure the air intake for the HVAC
system is located a sufficient distance from the system exhaust stack and any ventilation pipes.
(c) Check the system for accumulating water
or water leaks.
(d) Add appropriate treatment chemicals as
indicated by the equipment specifications.
(e) Re-balance system whenever its
configuration or the area served has changed.
(f) Perform an overall inspection of the
plumbing system including the following:
(1) Water leaks.
(2) Filled drain traps.
(3) Clogged ventilation pipes.
b. Housekeeping.
1. Establish a routine cleaning schedule that includes regular trash storage and pick-up, and cleaning of all surfaces. Store cleaning supplies in a designated room or closet.
2. Inform employees of the application schedules and storage areas for pesticides.
3. Smoking is permitted only in outside designated areas.
8.3 INDOOR EQUIPMENT USE
a. Combustion equipment commonly used indoors
such as forktrucks and generators can create serious health risks if used improperly. Combustion pollutants are the gases and particles made by burning any fuel such as wood, natural gas, kerosene, or charcoal. The major indoor combustion pollutants are carbon monoxide (CO), nitrogen dioxide (NO2), particles (PM10), and polycyclic aromatic hydrocarbons (PAHs). Whenever practicable, alternatives to gasoline burning motor vehicle equipment shall be considered when intended to be used indoors at the Center. Alternative power sources with less harmful emissions than gasoline include electricity, liquefied petroleum gas (propane), and compressed natural gas. In instances where no alternative is available, the equipment exhaust shall be vented directly to the outside and away from any air intakes.
b. Air cleaning devices that rely on ion generation and
electrostatic precipitation may produce ozone, particularly if they are not properly installed and
maintained. Ozone is a lung irritant, producing an unintended secondary indoor air quality hazard. The use of all air cleaning devices must be approved by the Safety Office prior to use. Often, engineering controls can be implemented to abate the indoor air quality concern. All air cleaning devices must be tested by the Underwriters Laboratory (UL) and used in accordance to manufacturer’s recommendations.
c. Indoor Temporary Heating Devices
1. Portable electric space heaters intended to be used indoors are permitted for use inside building of the Center only under the following two conditions:
(a) An employee has a medical condition that
renders the temperature ranges listed in Table 8-1 unacceptable. A physician’s note must be provided to the Safety Office.
(b) Engineering controls are unable to
maintain the workspace in the temperature ranges listed in Table 8-1. Temperatures outside of the recommended ranges during normal working hours must be documented by the Safety Office through temperature monitoring.
2. Typical indoor space heaters employ circulating oil or water or ceramic plates to radiate heat. All space heaters must be tested by the Underwriters Laboratory (UL), positioned on the floor of the work area (NOT on top of desks, machines, etc.), and used in accordance with manufacturer’s recommendations. Space heaters must have three feet of clearance from the nearest object. Space heaters must be turned off when the employee leaves the area. Furthermore, the following properties should be present in the heater:
(a) Have a tip-over switch that automatically
shuts off the unit in the event it is accidentally turned over,
(b) An indicator light that illuminates when the
unit is on, and
(c) An element guard to prevent anyone from
touching hot elements.
d. Outdoor Temporary Heating Devices
1. Outdoor temporary heating devices are
commonly used in construction. These devices are also known as Salamander heaters and Torpedo heaters. Their use is regulated under 29 CFR 1926.154.
Continue reading ↓ 120 of 450 passages shown