MAINTENANCE COORDINATION FOR AIR ROUTE TRAFFIC CONTROL CENTERS SUBJ: (ARTCC) .
1. PURPOSE. This Order assigns responsibility for maintenance coordination to the Airway Facilities Sector (AF$) at the Aif Route ~raffic Control Cen~er and provides special procedures to be followed 1n carry1ng out the respons1- ·
bilities.
2. DISTRIBUTION. This Order is distributed to the branch level in the· Airway Facilities, Air Traffic, and flight Standards DiVisions, to all flight
Inspection District Offices, and to all Airway Facilities and Air Traffic . field offices. ·
3. CANCELLATION. This Order cancels Order GL 6030.26 dated August 3, 1973.
4. GENERAL RESPONSIBILITIES. The Airway Facilities Sector Manager at the ARTCC Sector shall perform all liaison duties between the ARTCC Manager and the ~espective Airway Facilities Sector Manage.r within the Center flight advisory area. He shall serve as a technical advisor to the ARTC.C Manager on matters dealing with maintenance or continuity of facili.ty technical opera
tion. Systems E;ngineers (SE) shall be redelegated these responsibilities in keeping with their trainihg, experience, and grade level •.
5. AUTHORITY.
a. The ARTCC Assistant Manager has final authority to approve or disappove a maintenance shutdown or an extension of a shutdown of a navigational aid. When a navigational aid servesmore than one Center, the authority is vested in the Center in which geographical area the facility is located.
b. TheSE is authorized to coordinate proposed shutdown of navigational aids with adjacent ARTcc•s, control towers, combined station/towers, and flight service stations.
6. COORDINATION. The Systems Engineer (SE) shall contact the ARTCC Assistant Manager when. starting a shift of duty to see if any conditions exist that would require any facilities to be left in service for which shutdown has already been coordinated and approved •. The ARTCC Assistant Manager shall be:
(1) reminded by the SE of any routi rie shutdown approva J at least 30 minutes prior to the shutdown; and (2) advised of requests for shutdown approval for emergency or nonrouti ne reasons. ' . . . · .
,:'..
Distribution: A-XAF/AT/FS-3, A-fAF-0/fAT-O/FfS;..4 (STD). ·. lniti~te~.Sy: AGL-460
, . , 'JUL 1 9 1SSJ · ,' '· ..
7. ARTCC CONTROl.. AR~A COORDlNATION.
9. Pri pri ti ~s. The fpl1owi ng priori t.ies shall pe y~~~ b;Y t,he Sf: in processftfg facilfty shut~own requ~sts either in or ~ro~{:~nt. to the Center .control area.
(1) Priority I. A facility or a colocat~d ft~iHty hilure is fromi~ nent. (For example; Thti! miin cana $'t9nd!:>Y ~guipment§ ~re pef.e~tive and. req~Ji re · a shutdown for repair, or a- TACAN antenna is defective and r.eq~ires a ~OR ... shutdown to compl~te repairs or aetermfne c.ause of TACAN fa1lure~ &RY1Pfflent recertifitati on t.e§t~ and at:lju~rtments ~re Pri9r-i tY J wne.n requi r.ed b.V pfl «>t reports of ma1functi oni ng, } · · · .· ·
(2) Pr:ioritY lL '14 fH~ht check that r~quire5 _9 $hyt.ggwn~
(3) Pri~rity HL for ·~ch~duled in~inten9;nce.
(4) Priority IV. For unscheduled routine maintenance, maintenance inspections, technician .certific~tion .examirt~.tion~~ etc.
(5} ~riority v. For modifications and. improvements requiring a shutdown. ·
P.~ ·· Fielq Requ@§'t§.. Terminjl cang FS~ ~PIIlmYni.ca~ior,t ~hi$. ~ml i~rminal r~!l~r, .. visual a1d, and ,ngV.igati.on.al ~id ·shytd.Pwn r~qyests requin~ l<>cal .M r !rafffc · · approvaL This lp~l!).l ~pord,im~tion is t~~- r~spp.nsibjlity of :l;h(:! r~m9t~ Ar~ maintaining the facility~ Sh~t.down requ.ests for ART.CC en route radar, .. navigational aid, and comrm.inication facilities require approval of all the ARTCC's using the faciliti~s.· · · . · · ·
. · (1) Communication Medh Pref~rence. Requests fQr .shutdown, eKtensions
o~ sh~tdown,.·a~ij_fac~tity res:torapon notifiq~tions should be mad~ usin9 commun1cat1on fac1111n~s 1n the follovt1n9 orqer of preferen~~: · . . .
{a) For requests f~r shutdown:
. . . . 1 . Teletype
2 Interphone
2 Interphone
J telephone
. (p). For .extensions of S~!oitc;lown and fa~ility restoration:
1 .. Interphone
2 Telephone
3 Teletype
. (2) Deadline. for Request·s. Routine shutdown requests shall be. sent .in t 1me to be avan·a"b'l e to the 'St ·rro 1ater than 0600Z ori' the day the shutdown is desired. ·
3 Teletype
JUl 19 1983
(3) Scheduled·.Maintenance Shutdowns •... Requests must be made for a facflity maintenance shutdowneven though it is the facility's scheduled shutdown date~ ·
. . (4) Ch.anges to Planned Shutdowns. If circumstances change the Airway Facilities Sector shutdown" plans, theSE must be advised immediately. . ; . . : . . (S) Extensjons. · If additiOnal shutdown· time is required, ;a requ~st for an extension must be sent to the .SE with as much. lead time as poss1ble pr1or to the approved ff:!Storatjon time.
(6) Data Required;. All requests for shutdOWnS shall .include the following:
(a) ·Facility location and facility type.
(b) Outage time desired and estimated restoration time.
(c). Priority (see paragraph 7 above).
(d) Emergency restoration time. (Example: Emergency restoration 30 minutes.)
(e) The reason for the shutdown if unsch-eduled.
(7) Emergency Shutdowns. Emergency shutdowns shall be coordi na_ted with theSE prior to the shutdown.when pos·sible. The avoidance of imminent danger or d.amage to a fqcility will preclude any need for prior coordination in emergency cases.
(8) Project Shutdowns and Shutdo~n .Extensions~
. (a) Shutdown Noti.ces. Shutdown noti.ces and extensions to shutdowns for SMP, F&E, and similar projects will be initiated by the office controllinythe work (Region). Notification of facility shutdown should be in. Writing, allowing sufficient time for_ advance ARTCC coordination.· A copy of the notification should be sent to AGL-430 for incorporation into the monthly Facility Shutdown Schedule. ·
.. (b) Restoral Notices and Estimates. Restoral of a facility after a project will be reported by the AF Sector maintaining the facility. SE•s shall query the remote AFS near the end of the estimated shutdown period to determine if service will be restored or to ·get a revtsed estimate of return to service. The AT Assistant Manager shall be kept informed of the CI,Jrrent estimate of return to service for all such projects in process within that Center'i boundari~s.
c. SE Action on Shutdown Requests. All requests will be processed promptly.
(1) Approval. Notification of approval must be sent to the. requesting Sector in sufficient time to issue a Notice-to Airmen (normally 5 hours).
Par 7 Page 3
JUL 19 1983 GL 6030. 26A·· ·
JUL 19 1983 GL 6030. 26A·· ·
(2} Qi~HWJ?t9vaJ~ ·.If it is necessary to disapprove a .. request:~ notification Wfll· o~ sent to the originating Sector. prior.to the time a Notice to Airinen would have·to be published. Reason for disapproval and suggested alternative time(s) should be furnished if appropriate ..
{3) . Ga~G~J1~tjpn~ Apptoval for a, faCility snu.tdown rtut.y b~ can~e1Jed whenever an emergency exists or there are unusual traffic conditions. · R~a~on
for cancellation and· sugge,sted alternate time( s) should be furnished if appropriate.
d. Pri.orit.Y Res.torati,on. When two or more navigational aids become·.· inoperative and it is 'not possible to repair themsimultaneous1y, the SE shall .. ask the Airway Facilities personnel to furnish an estimate of the time required
to restore each facility. to operation. The ARTCC Asststaht Manager shall establish a .priority of restoration. · ·
e. Adjacent ARTCC Coordin~:t;ion..
(1) Requests to ARTCC' S• The SE shaH coord1 nate all shutdown requests with the Centers that have facn ities adjacent to the facility being proposed
for shutdown~
(2) Request~ frol!ln.o:ther A!rf~c·~· When a request for shutdown is received from an adjacent Center, the SE shall check facility shutdown requests and facility outMes to see if there is any conflict with adjacent facility . shutdowns.' and honor- the request With highest priority as out1 ined in paragr.aph 7 above: · .· · · · ·
(3) StaJl,ls Ctt.~.rHiJ.~.~. The SE sha11 advise the. appropriate adjacent Center .when a scheduled shutdown of an adjacent facility is changed, returned to · service, or when a facility has failed. · ·
(4) Access :to :IotetphoJte Git:cl1i:ts. The SE sha11 have access to i nterphone circuit$ to adjac~nt Centers~ · Conversations shall be kept brief and are.subject to AT interruptions. ··
8. ALERT BULLETINS.
. . . a •..Aiert Type Information_. Alert items should be of the critical type . which have management, politiCal~ ot public interest impact generated during the preceding 24 hours .. · the objettive of alert bulleti~s is to. keep the Oi r~ctor and the Administrator currently aware of situations which might result irt inquiries that day fromoffiCialsof'the·.White House, Congress, Bureau of the
Budget~ embassies, .the avi'atfon industry,· aviation unions. and the pte$$. . . . . ' b. Failure of Facilities. Failures of facilities
..
that
-
result in traffic flow problemsand unanticipated Great Lakes Region facility outages of. more than 24 hours are to be feported· by· the SE to the Regional Communications .Control Center (RCCC) and AGL-430. The ARTCC AF Sector shall mafritaih a list of .... telephone numbers. and persons (see paragraph 8c bel ow) to notify concerning extended outages. Acop)' of this 1i st sha11: be· avaHab le. to th.e SE in tM control room. · · '
Pa~e 4 Par 7
JUL 1 B 1983
c. Reportjng Ptocedure~.. The SE shall report alert items to the.: Great .Lakes Regional···C.ommuni.cations. Control .Center• bY ... the~·most. expeditious·.·method ·
possible •. Members of the Airway Facilities DiVision staff shall be notified in accordance with Order GL 8020.198. The following information shall be furnished when reporting an' a 1ert i tern: >
(l) Estimated time the fadlity Will be restor.ed •..
(2) Equipment i.nvol ved.
(3) A brief description of the cause, e.g.; power, TELCO, equipment failure;. weather, flooding, earthquake, etc.
(4) Time out and restored.
> > (5) ··If not restored, state thecorrective action being taken. · .. d. Adjacent Regions. Alert items within a particular Center area but in a different region shall be reported to the· region in which the facility is
located in accordance with instructions issu~ by that region. · ·
9. IN-FLIGHT PILOT REPORTs.·
9. IN-FLIGHT PILOT REPORTs.·
. a •. Out-of-Toleran:ce Conditions. The SE iS responsible for determining . whether or not In-Flight Pilot Reports received in th~ Genter .. indicate a
. possible out-of~to·lerance condition of, faCility, operation. The SE will initiate·.
the· necessary notification to assure investigation and possible corrective action. ·
b. Publications. The following related publications provide background information for fulfillinent of these responsibilities:
(1) Order OA P 8200.1. Conditions described in two successive In-Flight Pilot Reports mustexceedtolerances permitted by this handbook before facility shutdown and recertification iS required.
(2) Airman•s Information· Manual AIM). Restric:;tio.ns to use of certain navig9tional aids· i;lre pub fshed in the M. ·· he SE shall consider these restrictions when deciding if recertffic;at'ion is required·~ · Take .no fl!rther action .if thecondition reported is carried inthe current issue of the AIM.
10. FLIGHT CHECK.
a. AdvancE(Notice. Flight Check Specialists> {pilots) who· will have a requirement for partidpat'i~n ·o·i'-electrohic technician's and/or traffic controllers at the Center during flight checks shall give the ARTCC AFS at 1east 2 hours advance notice.
b. Action bX ARTCC.. AF~ •.. ·Upon receipt of notification of the requirement for efectronic technicians an'd/or. traffic controllers for flight checks, the SE shall: ·
JUll 9.1983 Gl, 6030. 26A' · .
. (1) Regue.st.·.th~tSites t>e Manned. As.sure that per~onnel are available at the 1 oca 1 and r.emote fac ili tjes>to :make·. adjustments as may ·be requi.red. A11 . necessary.eq·uipment c.hecks·and calibrations should be accomplished before the··.. flight chec.k begins.. ·
(2) Arrang7 fo~ Communi:ationsand ARTCC Part~dp?tion~ Pr~v~·de the necessary video mon1tor1ng ·and pllot-controller commun1cat1ons capab1l1ty for participating personnel. .
(3) Arrange with Air Traffic Assistant Manager· so he may schedule ·sufficient .participation by. C()ntroller personnel.
11. ACCIDENT/lNCIDENT PROCEDURES •
11. ACCIDENT/lNCIDENT PROCEDURES •
.a~ _Air_wa,x,.{acilitie~ Respons}bp~ty. The responsibilit~eso~ the A.irway Fac111 t1 es serv1ce .and A1rway Fac1ht1e~ pers.onnel are qmta1 ned 1n pa:r.agraphs 135 and 153 in Order.8020.lland. its regional supplements. . . ' . b. Accidents. When notification of an aircraft accident is received; .the ARTCC SE shal1 : . . . - ·. ·. . .. . .
(1) Assist Air Traffic Personnel. · Help to determine if performance of. a facility or facilities may have been·a factor. ·
· . (2) ·. t{ot.ify AF's Con~erned... If facilities may be Jnvol ve<:t," inform the .··
re~po:ns.ib.'le Airw~.tFaciliti.Qs Sector ~nager immediately and carry .out the . instructions contained in Order 8020.11 and its regional supplements •.
· (3) Ncrtify AF Division AccidentReereserH:atiVe•. Notify the AF Division as instructed by ·Order GL. OOZO,.l9B •. · · .. . . . .· . . . ·_ . . . : . . c. Inciden.ts. When. an incident report is received, the· SE will, .upo·n the recommendation of, Air lr'i:iffH: p~r~onnel, carry out the pertinent instructions contained i-n Ora~.f' 8020~11 a·nEi its. regional supplements·. . ·.· . ·
12 •. DEFENSE PREPAREDNESS.
a. Defense Postures. Defense preparedness +smaintained through five ... . different defense rea,di ness postures.· Eacb qefen:se readi~s.s postur~, ninnbet~
five through ooe', repre·sent:S a.. posture in whi.ch preparations for emergency action are progressively advanced.. · · · · · ' ·
b. Coordination.. The SE wi 11 be the coordinator for all defense· readi.ness actions for t.he Center AFS a,s. prescrib:e.dr in. the predetermined emergency . readiness procedures •.. Emergency acttons wi 1.1 be coordinated with the ARTCC Ass i stant Manager. · ' ·
13., FACILITY STATUS REPORTS~
13., FACILITY STATUS REPORTS~
The NatiO;nal Ainspace System (NAS) :; s an intricate sys~em which· includes- more than 19,000 facilities. To. better manage this complex system, FAA. management personnel require current and accurate data that reflectsthe condition of the
·. JUL 1 9 1983
NAS ai1d the effects on the safe movement of ai r traffic. The Oa i 1 y NAS Status Report provides this information. Order 6040.15, National Airspace Performance Reporting System, will serve as tile source for definitions; procedures, and requirements for reporting air traffic delays and interruptions to facilities and services in the NAS. · · ·
\\ ,J'{\~~«-.~~ ~ P. K. Bohr · . . Dir~ctor . ·
Par 13 Page 7