Radar Vectors
Advisory Circular Cancelled Issued Nov 16, 2020 AJV-P 116 pages Copy saved Nov 18, 2026

AC 70/7460-1M Obstruction Marking and Lighting

This Advisory Circular (AC) describes the Federal Aviation Administration’s standards for marking and lighting structures to promote aviation safety.

This document is no longer current. Cancelled by 70/7460-1N. Check the official source before relying on it.

Official source ↗ Open PDF

Text read by OCR from a scanned file (1 of 116 pages). Check the original, as some words may be misread.

AC 70/7460-1M, Obstruction Marking and Lighting

Advisory

Circular

Obstruction Marking and Lighting

Date: 10/29/2024

Initiated By: AJV-P13

Advisory

U.S. Department Circular of Transportation

Federal Aviation Administration

Date: 11/16/2020 Subject: Obstruction Marking and Lighting

AC No. 70/7460-1M Initiated By: AJV-P13

Purpose.

This Advisory Circular (AC) describes the Federal Aviation Administration’s standards for marking and lighting structures to promote aviation safety.

Cancellation.

AC 70/7460-1L, change 2, Obstruction Marking and Lighting, dated August 2018 is cancelled by this version.

Effective Date.

This AC is effective November 16, 2020.

Related Documents.

Title 14 of the Code of Federal Regulations Part 77 describes the standards used relative to objects in the navigable airspace and specifies the requirements for notice to the Administrator of certain proposed construction or alteration. Federal Communications Commission (FCC) specifications are contained in Part 17 of the FCC Rules and Regulations.

Principal Changes.

This circular contains numerous editorial changes. Major changes are listed below.

a. Page 2, Addition of Note. The FAA has changed specifications for light emitting diode

(LED)-based red obstruction lights to make them visible to pilots using certain night vision goggle systems. Effective with the implementation of this change in FAA AC 150/5345-43, Specification for Obstruction Lighting Equipment, manufacturers will be required to meet the new specification for certified red LED-based obstruction lights. b. Page 6, Removed paragraph 2.8, Obstruction Height Definition. Structures lower than 499

feet AGL can be considered obstructions. As written, the paragraph caused confusion and was deleted. c. Informational paragraphs are added regarding the change to manufacturing standards for

LED-based red obstruction lights compatibility with night vision goggle systems and maintaining conspicuity to avoid misinterpretation when replacing lights. d. Reorganized information in Chapter 11, Marking and Lighting of Catenary and Catenary

Support Structures and chapter 13, Marking and Lighting Wind Turbines. e. Reorganized chapters by subject matter and figures in Pages A-1 to A-29, as well as

minor grammatical changes.

ii

f. Added Chapter 14, Marking and Lighting Temporary Structures and associated figures in

the Appendix, Figures A-31 through A-33. g. Added Figure 22, Catenary Markers - Line Spacing (Adjacent Lines Within 200 feet

(60.96 m) or Less. h. Added Figure 30, Wind Turbine Lighting During Construction.

Federal Aviation Administration Manager, Policy Assurance Attention: AJV-P13 600 Independence Avenue, S.W. Washington, DC 20591

KAREN L

CHIODINI

Digitally signed by KAREN L CHIODINI

Date: 2020.11.14

12:21:32 -05'00'

Karen Chiodini, Director (A) Policy, AJV-P

Mission Support Services Federal Aviation Administration

iii

iv

Advisory

Circular

Subject: Obstruction Marking and Lighting Date: 10/29/24 Initiated By: AJV-P13

AC No: 70/7460-1M, Change 1

Purpose.

This Advisory Circular (AC) describes the Federal Aviation Administration’s standards for marking and lighting structures to promote aviation safety. The contents of this document do not have the force and effect of law and are not meant to bind the public in any way, and the document is intended only to provide information to the public regarding existing requirements under the law or agency policies.

Audience.

This Advisory Circular applies to structure Sponsors, and serves as a reference tool for the Mission Support Services, Obstruction Evaluation Group and Office of Airports.

Effective Date.

This AC is effective October 29, 2024.

Related Documents.

a. Title 14 of the Code of Federal Regulations Part 77 describes the standards used relative to

objects in the navigable airspace and specifies the requirements for notice to the Administrator of certain proposed construction or alteration. b. Federal Communications Commission (FCC) specifications are contained in Parts 17 and 47

of the FCC Rules and Regulations. c. Sponsors are required to contact the United States Coast Guard (USCG) for prior approval

for the lighting of bridges according to 33 CFR 118.

Principal Changes.

This change is to update or correct information and modify standards to include new methods of marking structures and remove the use of steady-burning lights on tower structures. The change also clarifies information regarding modifications and deviations; updates verbiage to reflect the non-regulatory nature of the advisory circular and Meteorological Evaluation Tower name; as well as numerous editorial and formatting updates. Information regarding the major changes is listed below.

a. Page 1, Chapter 1, Paragraph 1.5. The information regarding modifications and

deviations is updated to clearly define the meaning of each, as well as how they are requested by Sponsors and analyzed by the FAA. b. Page 10, Chapter 2, Paragraph 2.7. The name of Meteorological Evaluation Towers is

changed to meteorological towers. There is no abbreviation for the title of Meteorological Tower(s), so the use of “MET” for these structures is removed.

c. Page 53, Chapter 15, Paragraph 15.2.2 item 2. and throughout the document. The FAA

has approved the use of alternative methods of marking structures, vinyl wrapping and powder coating, in addition to painting. This change adds information regarding the marking standards for the use of these methods. Additionally, due to these new marking methods for structures, paint is no longer the sole source and the term “marking” has replaced “painting” as appropriate throughout the AC. d. Flashing side lights have replaced steady burning lights to avoid avian confusion and

provide a level of protection to reduce deaths. Existing structures lit with steady burning lighting is acceptable at this time. However, as these lights necessitate replacement, they should be upgraded to flashing lights. All new construction requires the installation of flashing lights. e. In paragraphs 7.6, 7.7. and 9.5 corrected the alphanumeric lighting type to reflect

medium-intensity lighting. f. The informational paragraph in Appendix B has been updated to clearly reflect the

information as the application of data from Table-B and Figure B-1 to calculate pilot visibility of structures. g. Addition of Advisory Circular Feedback page (last page). h. Throughout the document, verbiage has been updated to reflect the non-regulatory nature

of an advisory circular. Examples include changing the use of the word “must” to “should” and “requirements” to “recommendations” or “standards” as appropriate. i. Editorial/format changes throughout the document were made where necessary, including

Appendix A.

Application

The FAA recommends the guidelines and standards in this AC for determining the proper way to light and mark obstructions affecting navigable airspace. This AC does not constitute a regulation and, in general, is not mandatory. However, a sponsor proposing any type of construction or alteration of a structure that may affect the National Airspace System (NAS) is required under the provisions of Title 14 Code of Federal Regulations to notify the FAA by completing the Notice of Proposed Construction or Alteration form (FAA Form 7460-1).

If you have suggestions for improving this AC, you may use the Advisory Circular Feedback Form on the last page of this document.

Federal Aviation Administration 600 Independence Avenue, S.W., Attention: AJV-P13 Washington, DC 20597-5580

Michael Beckles Director, Policy, AJV-P Mission Support Services | Air Traffic Organization Federal Aviation Administration

v

AC 70/7460-1M, Obstruction Marking and Lighting › Table of Contents

Table of Contents

Paragraph Page

Chapter 1. ADMINISTRATIVE AND GENERAL PROCEDURES … 7

1.1 Reporting Requirements … 7

1.2 Preconstruction Notice … 7

1.3 FAA Acknowledgement … 7

1.4 Supplemental Notice Requirement … 7

1.5 Modifications and Deviations … 7

1.6 Additional Notification … 9

Chapter 2. GENERAL … 10

2.1 Structures to be Marked and Lighted … 10

2.2 Guyed Structures … 10

2.3 Marking and Lighting Equipment … 10

2.4 Light Failure Notification … 11

2.5 Notification of Restoration … 11

2.6 Federal Communications Commission (FCC) Requirement … 12

2.7 Voluntary Marking of Meteorological Towers Less Than 200 Feet (60.96 m) AGL … 12

Chapter 3. MARKING GUIDELINES … 13

3.1 Purpose … 13

3.2 Marking Colors … 13

3.3 Marking Standards … 13

3.4 Marking Patterns … 14

Table 3-1: Structure Height to Bandwidth Ratio … 15

3.5 Unlighted Markers … 16

3.6 Flag Markers … 18

3.7 Omission or Alternatives to Marking … 18

3.8 Unusual Complexities … 19

Chapter 4. LIGHTING GUIDELINES … 20

4.1 Purpose … 20

4.2 Standards … 20

4.3 Lighting Systems … 20

Table of Contents

Paragraph Page

4.4 Inspection, Repair, and Maintenance … 22

4.5 Nonstandard Lights … 22

4.6 Placement Factors … 22

4.7 Monitoring Obstruction Lights … 24

4.8 Ice Shields … 24

4.9 Light Shields … 24

4.10 Distractions … 24

Chapter 5. RED OBSTRUCTION LIGHT SYSTEM … 26

5.1 Purpose … 26

5.2 Standards … 26

5.3 Control Device … 27

5.4 Alternate Method of Displaying Obstruction Lights … 27

5.5 Poles, Towers, and Similar Skeletal Structures … 27

5.6 Chimneys, Flare Stacks, and Similar Solid Structures (except Hyperbolic Cooling Towers) … 29

5.7 Prominent Buildings, Bridges, and Similar Extensive Obstructions … 30

5.8 Group of Obstructions … 31

Chapter 6. MEDIUM INTENSITY FLASHING WHITE OBSTRUCTION LIGHT

SYSTEMS … 32

6.1 Purpose … 32

6.2 Standards … 32

6.3 Control Device … 32

6.4 Radio and Television Towers and Similar Skeletal Structures … 33

6.5 Chimneys, Flare Stacks, and Similar Solid Structures … 34

6.6 Prominent Buildings and Similar Extensive Obstructions … 34

6.7 Group of Obstructions … 35

6.8 Special Cases … 35

Chapter 7. HIGH INTENSITY FLASHING WHITE OBSTRUCTION LIGHT

SYSTEMS … 36

7.1 Purpose … 36

7.2 Standards … 36

Table of Contents

Paragraph Page

7.3 Control Device … 36

7.4 Units per Level … 37

7.5 Installation Guidance … 37

Table 7-1 Light Unit Elevation Above the Horizontal … 37

7.6 Radio and Television Towers and Similar Skeletal Structures … 38

7.7 Antenna or Similar Appurtenance Light … 39

7.8 Chimneys, Flare Stacks, and Similar Solid Structures … 39

7.9 Prominent Buildings and Similar Extensive Obstructions … 39

7.10 Hyperbolic Cooling Towers … 40

7.11 Special Cases … 40

Chapter 8. DUAL LIGHTING WITH RED/MEDIUM INTENSITY FLASHING WHITE

LIGHT SYSTEMS … 42

8.1 Purpose … 42

8.2 Installation … 42

8.3 Operation … 42

8.4 Control Device … 42

8.5 Antenna or Similar Appurtenance Light … 43

8.6 Mounting Lights … 43

8.7 Omission of Marking … 44

Chapter 9. DUAL LIGHTING WITH RED/HIGH-INTENSITY FLASHING WHITE

LIGHT SYSTEMS … 45

9.1 Purpose … 45

9.2 Installation … 45

9.3 Operation … 45

9.4 Control Device … 45

9.5 Antenna or Similar Appurtenance Light … 46

9.6 Omission of Marking … 46

Chapter 10. AIRCRAFT DETECTION LIGHTING SYSTEMS … 47

10.1 Purpose … 47

10.2 General Standards … 47

Table of Contents

Paragraph Page

Chapter 11. MARKING AND LIGHTING OF CATENARY AND CATENARY

SUPPORT STRUCTURES … 50

11.1 Purpose … 50

11.2 Lighted Spherical Markers … 50

11.3 Catenary Marking Standards … 50

11.4 Catenary Lighting Standards … 54

11.5 Control Device … 55

11.6 Area Surrounding Catenary Wire Support Structures … 56

11.7 Three or More Catenary Wire Support Structures … 56

Chapter 12. MARKING AND LIGHTING MOORED BALLOONS AND KITES … 57

12.1 Purpose … 57

12.2 Standards … 57

12.3 Marking … 57

12.4 Purpose … 57

12.5 Operational Characteristics … 58

Chapter 13. MARKING AND LIGHTING WIND TURBINES … 59

13.1 Purpose … 59

13.2 General Standards … 59

13.3 Wind Turbine Configurations … 59

13.4 Marking Standards … 60

Table 13-1. Wind Turbine Marking Standard Colors … 60

13.5 Lighting Standards … 60

13.6 Wind Turbines Above 499 Feet (152.10 m) … 62

13.7 Wind Turbines at or Above 699 Feet (213.36 m) … 62

13.8 Lighting of Wind Turbines During Construction Phase … 63

13.9 Lighting and Marking of Airborne Wind Turbines … 63

13.10 Lighting and Marking of Offshore Wind Turbines … 63

Chapter 14. MARKING AND LIGHTING TEMPORARY STRUCTURES … 64

14.1 Purpose … 64

14.2 General Standards … 64

14.3 Marking Standards … 64

Table of Contents

Paragraph Page

14.4 Lighting Standards … 65

14.5 Operational Characteristics … 68

Chapter 15. MARKING AND LIGHTING EQUIPMENT AND INFORMATION … 69

15.1 Purpose … 69

15.2 Marking Standard … 69

Table 15-1: Aerospace Material Specification Standard, SAE AMSSTD595A … 69

15.3 Availability of Specifications and Advisory Circulars … 70

15.4 Lights and Associated Equipment Standards … 70

15.5 Availability of Military Specifications … 71

APPENDIX A. SPECIFICATIONS FOR OBSTRUCTION LIGHTING EQUIPMENT

CLASSIFICATION … A-1

Figure A-3. Marking and Lighting of Water Towers, Storage Tanks, and Similar

Figure A-7. Dual Lighting of Poles, Towers, and Similar Structures/Lighting and

Figure A-13. High-Intensity White Obstruction Light Standards (FAA Style B)—

Figure A-14. High-Intensity White Obstruction Light Standards (FAA Style C)—

Table A-1: FAA-Approved Obstruction Lighting Fixtures … A-1

Figure A-1. Meteorological Tower Marking Standards (Monopole Structure) … A-2

Figure A-2. Meteorological Tower Marking Standards (Guyed Structure) … A-3

Structures … A-4

Figure A-4. Marking and Lighting of Water Towers and Similar Structures … A-5

Figure A-5. Marking a Single Pedestal Water Tower Using the Teardrop Pattern … A-6

Figure A-6. Red Obstruction Light Standards (FAA Style A) … A-8

Painting of Chimneys … A-8

Figure A-8. Bridge Lighting … A-9

Figure A-9. Medium-Intensity White Obstruction Light Standards (FAA Style D) … A-10

Figure A-10. Lighting of Chimneys, Flare Stacks, or Similar Solid Structures … A-11

Figure A-11. Lighting Adjacent Structures—Light Level Adjustment … A-12

Figure A-12. Lighting Adjacent Structures … A-13

With Appurtenance 40 Feet or Less … A-14

With Appurtenance Over 40 Feet High … A-15

Figure A-15. Lighting Hyperbolic Cooling Tower … A-16

Figure A-16. Medium-Intensity Dual Obstruction Light Standards (FAA Style E) … A-17

Table of Contents

Paragraph Page

Figure A-17. Medium-Intensity Lighting—Establishing the Location of Top

Beacons … A-18

Figure A-18. High-Intensity Dual Obstruction Light Standards (FAA Style F)—

Figure A-19. High-Intensity Dual Obstruction Light Standards (FAA Style G)—

Figure A-22. Catenary Markers – Line Spacing (Adjacent Lines Within 200 Feet

With Appurtenance Over 40 Feet High … A-19

With Appurtenance 40 Feet or Less … A-20

Figure A-20. Aircraft Detection Lighting System (sample coverage map) … A-21

Figure A-21. Catenary Unlighted Markers (less than 69 kV) … A-22

(60.96 m) or Less) … A-23

Figure A-23. Catenary Markers - Line Spacing (Adjacent Lines Greater Than 200

Feet (60.96 m) Away) … A-24

Figure A-24. Catenary Lighted Markers – Used in Conjunction with Unlighted

Markers (69 kV or greater) … A-25

Figure A-25. Catenary Obstruction Lighting … A-26

Figure A-26. Wind Turbine Lighting Configurations … A-27

Figure A-27. Lighting and Marking of Wind Turbines – Paint Schemes … A-28

Figure A-28. Wind Turbine Lighting and Marking in Snow Prone Areas (Optional) … A-29

Figure A-29. Wind Turbine Lighting … A-30

Figure A-30. Marking and Lighting of Turbines During Construction … A-31

Figure A-31. Crawler Crane Marking and Lighting … A-32

Figure A-32. Tower Crane Marking and Lighting … A-33

Figure A-33. Container Crane Marking and Lighting … A-34

APPENDIX B. MISCELLANEOUS … B-1

B.1 Rationale for Obstruction Light Intensities … B-1

B.2 Distance Versus Intensities … B-1

Table B-1. Distance and Intensity … B-1

Figure B-1. Acquisition Distance Calculation … B-2

B.3 Application … B-2

B.4 Definitions … B-3

APPENDIX C. ACRONYMS … C-1

APPENDIX D. ADVISORY CIRCULAR FEEDBACK FORM … D-1

Chapter 1. ADMINISTRATIVE AND GENERAL PROCEDURES › 1.5 Modifications and Deviations.

CHAPTER 1. ADMINISTRATIVE AND GENERAL PROCEDURES

1.1 Reporting Requirements. A Sponsor proposing any type of construction or alteration of a structure that may affect the National Airspace System (NAS) as required under the provisions of Code of Federal Regulations (CFR), Title 14, Aeronautics and Space, Part 77, Safe, Efficient Use, and Preservation of the Navigable Airspace (14 CFR, Part 77), must notify the Federal Aviation Administration (FAA) by completing the FAA Form 7460-1, Notice of Proposed Construction or Alteration.

This form should be filed electronically at https://oeaaa.faa.gov. The website includes the FAA Notice Criteria Tool for Sponsors use to determine if the structure exceeds criteria threshold and requires a notice to be filed.

1.2 Preconstruction Notice. The notice must be submitted:

1. At least 45 days prior to the date of proposed construction or alteration is to begin.

2. On or before the date an application for a construction permit is filed with the Federal Communications Commission (FCC). The FCC advises its applicants to file with the FAA well in advance of the 45-day period to expedite FCC processing.

1.3 FAA Acknowledgement. The FAA will acknowledge, electronically, each FAA Form 7460-1 notice received.

1.4 Supplemental Notice Requirement.

1.4.1 If required, the FAA will include a statement requiring the filing of FAA Form 7460-2, Notice of Actual Construction or Alteration, on the determination. All FAA Forms 7460-2 should be filed electronically at https://oeaaa.faa.gov.

1.4.2 FAA Form 7460-2, Part 1, must be submitted to the FAA at least ten days prior to starting the actual construction or alteration of a structure. The FAA Form 7460-2, Part 2, completed within five days after the structure has reached its greatest height.

1.4.3 In addition, notification of dismantlement or abandonment of construction must be submitted to the FAA using the supplemental notice FAA Form 7460-2.

Note: Notification as required in the determination is critical to aviation safety.

1.5 Modifications and Deviations. Requests for modification or deviation from the standards outlined in this Advisory Circular (AC) should be submitted to the FAA Obstruction Evaluation Group (OEG) by submitting FAA Form 7460-1, Notice of Proposed Construction or Alteration, to

1.5 Modifications and Deviations. › 1.5.2 `Deviations.

determine the potential effect on aviation safety. The Sponsor is responsible for adhering to approved marking and/or lighting limitations, and recommendations given, and should notify the FAA and FCC (for those structures regulated by the FCC) prior to making any changes, such as removal of marking and/or lighting.

1.5.1 Modifications. A Sponsor may request a modification from the marking and lighting recommendations contained in a determination to the OEG to use alternative methods or configurations from the AC standards. Requests received for any changes after a determination has been issued will require a new aeronautical study and may result in a modified determination, including updated marking and/or lighting recommendations. If the FAA issues a modification from the marking or lighting requirements prior to the implementation of the changes, the Sponsor may also be required to notify the FCC. Some examples of modifications are as follows:

1. Marking and/or lighting only a portion of an object. The object may be located with respect to other objects or terrain that only a portion of it needs to be marked and/or lighted.

2. No marking and/or lighting. The object may be located with respect to other objects or terrain, removed from the general flow of air traffic, or may be so conspicuous by its shape, size, or color that marking or lighting would serve no useful purpose.

3. Voluntary marking and/or lighting. The object may be located with respect to other objects or terrain that the Sponsor feels increased conspicuity would better serve aviation safety. Sponsors who desire to voluntarily mark and/or light their structure should do so in accordance with this AC.

4. Marking or lighting an object in accordance with the standards for an object of greater height or size. The object may present such an extraordinary hazard potential that higher standards may be recommended for increased conspicuity to ensure aviation safety.

The FAA strongly recommends that Sponsors become familiar with the different types of lighting systems and specifically request the type of lighting system desired when submitting FAA Form 7460-1. Information regarding types of lighting systems is provided in Chapters 5 - 10, and specifications regarding lighting equipment classifications in Appendix A, Table A-1, in this AC. While the FAA will make an effort to accommodate the structure Sponsor’s request, Sponsors should also request information from system manufacturers to determine which system best meets their needs based on purpose, installation, and maintenance costs.

1.5.2 `Deviations. The assigned Obstruction Evaluation Specialist will forward the request to the FAA Airport Safety Research and Development Section to conduct analysis and testing of the proposed deviation(s) for approval of use or to initiate testing in cooperation with the FAA. Proposed requests to deviate from current marking and lighting standards for research and development to introduce new technology or improve current standards. The FAA will perform a safety assessment for use in the NAS and may request status

Chapter 1. ADMINISTRATIVE AND GENERAL PROCEDURES › 1.6 Additional Notification.

reports and/or additional information as needed. If at any time the FAA determines the study has created an unsafe condition, the deviation request may be terminated. Research and development testing is independent of the aeronautical study process and generally requires a more lengthy analysis period for evaluation by the FAA for aviation safety. When testing is complete and the FAA concludes its review, the Sponsor will be notified of the determination. Examples of deviations that may be considered include, but are not limited to alternative painting schemes, colors/types of lights, basic signals and intensity of lights, night/day lighting combinations, and flash rate.

1.6 Additional Notification. Proper authorization and annotations of obstruction marking and lighting may require the Sponsor to provide notice to the FCC prior to making any change to the submitted information which the FAA based its determination. This includes modification, deviation, or optional upgrade to white lighting on structure, which may be subject to inspection and enforcement of marking and lighting requirements by the FCC. FCC forms and bulletins can be obtained from the FCC’s National Call Center at 1-888­ CALL-FCC (1-888-225-5322) or online at: Forms | Federal Communications Commission (fcc.gov) and Antenna Structure Registration (ASR) - Forms | Federal Communications Commission (fcc.gov). Additionally, upon completion of the actual change complete the Supplemental Notice (FAA Form 7460-2) at the https://oeaaa.faa.gov website.

Chapter 2. GENERAL › 2.3 Marking and Lighting Equipment

CHAPTER 2. GENERAL

2.1 Structures to be Marked and Lighted Any temporary or permanent structure, including all appurtenances, that exceeds any obstruction standard contained in 14 CFR Part 77 or an overall height of 200 feet (60.96 m) above ground level (AGL) should be marked and/or lighted. However, an FAA aeronautical study may reveal that the absence of marking and/or lighting will not impair aviation safety. Conversely, the object may present such an extraordinary hazard potential that higher standards may be recommended for increased conspicuity to ensure aviation safety. Recommendations for marking and/or lighting structures can vary, depending on terrain features, weather patterns, geographic location, number of structures, and overall design layout. The FAA may also recommend marking and/or lighting a structure that does not exceed 200 feet (60.96 m) AGL or 14 CFR Part 77 standards because of its particular location. The marking and lighting configurations are illustrated in Appendix A.

2.2 Guyed Structures Properly maintained marking and lighting are important for increased conspicuity because the guys of a structure are difficult to see until the aircraft is dangerously close. Section 91.119 of 14 CFR requires pilots, when operating over other than congested areas, to remain at least 500 feet (152.40 m) from man-made structures. Therefore, the tower must be cleared by 2,000 feet (609.60 m) horizontally to avoid all guy wires. The guys of a 2,000-foot (609.60 m) skeletal tower are anchored between 1,600 feet (487.68 m) and 2,000 feet (609.60 m) from the base of the structure. This places a portion of the guys 1,500 feet (457.20 m) from the tower at a height of between 125 feet (38.10 m) and 500 feet (152.40 m) AGL.

2.3 Marking and Lighting Equipment Considerable effort and research were expended to determine the minimum marking and lighting systems and quality of materials that will produce an acceptable level of aviation safety. The FAA will recommend only those marking and lighting systems that meet established technical standards and commercial outside lighting should not be used in lieu of FAA recommended marking and/or lighting. While additional lights may be desirable to identify an obstruction to air navigation, and may on occasion be recommended, the FAA will recommend minimum standards in the interest of safety, economy, and related concerns. Therefore, to provide an adequate level of safety, obstruction lighting systems should be installed, operated, and maintained in accordance with the recommended standards herein. Chapter 15 contains descriptions of FAAapproved obstruction marking and lighting equipment and information referred to in this AC.

Chapter 2. GENERAL › 2.5 Notification of Restoration

2.4 Light Failure Notification Sponsors should consider that conspicuity is achieved only when all recommended lights are working. Partial equipment outages decrease the margin of safety. Any flashing light outage should be REPORTED IMMEDIATELY AND corrected as soon as possible. Failure of steady-burning side or intermediate lights should be corrected as soon as possible, but notification is not required.

Manufacturers are required to meet FAA specifications for certified red LED-based obstruction lights to make them visible to pilots using certain night vision goggle systems. FAA AC 150/5345-43, Specification for Obstruction Lighting Equipment, specification ensures the light is visible to pilots operating with night vision goggles, to avoid the risk of a pilot misinterpreting the tower height if a legacy intermediate-level light is replaced with one that meets the specification unless the top light meets the new specification as well. Therefore, if a legacy specification intermediate-level LED-based light is replaced with a light that meets the specifications, then the top-level light(s) on the obstruction should also be updated to ensure the entire obstruction is visible during the use of night vision goggles.

2.4.1 Any failure or malfunction that lasts more than thirty (30) minutes and affects a top light, flashing obstruction light regardless of its position, wind turbine lighting fixture, or wind turbine synchronization should be reported immediately by calling Outage Reporting and Notice to Air Missions (NOTAM) at 877-487-6867, or in Alaska 800­ 478-3576, so a NOTAM can be issued. For structures that are regulated by the FCC, the FCC advises that noncompliance with notification procedures could subject the Sponsor to penalties or monetary forfeitures. Voluntarily installed lights (not recommended in an FAA determination) do not require a NOTAM.

2.4.2 The following information should be specified for outage reporting:

1. Name of persons or organizations reporting the light failures, including any title, address, and telephone number.

2. The type of structure.

3. Location of structure (including latitude and longitude, prominent structures, landmarks, etc.).

4. Height of structure AGL/above mean sea level (AMSL) if known.

5. Return to service date.

6. FCC Antenna Structure Registration Number (for structures that are regulated by the FCC).

Note: When the primary lamp in a double obstruction light fails and the secondary lamp comes on, no report is required.

2.5 Notification of Restoration As soon as normal operation is restored, notify Outage Reporting and NOTAM Offices (see Paragraph 2.4.1).

2.7 Voluntary Marking of Meteorological Towers Less Than 200 Feet… › 2.7.3 Spherical markers.

Note: For structures regulated by the FCC, the FCC advises that noncompliance with notification procedures could subject the Sponsor to penalties or monetary forfeitures.

2.6 Federal Communications Commission (FCC) Requirement The use of a high intensity flashing white lighting system on structures located in residential neighborhoods (as defined by applicable zoning laws) trigger requirements for FCC licenses and an environmental assessment.

2.7 Voluntary Marking of Meteorological Towers Less Than 200 Feet (60.96 m) AGL The FAA recommends marking of meteorological towers less than 200 feet (60.96 m) AGL in accordance with marking guidance contained in this AC. Historically, this guidance has not been applied; however the FAA recognizes the need to address safety impacts to low-level agricultural flight operations and believes that marking meteorological towers less than 200 feet (60.96 m) AGL in remote and rural areas enhances the conspicuity of these structures.

2.7.1 Marking. The meteorological tower should be marked in accordance with the standards and criteria contained in Chapters 3 and 15, with alternating bands of aviation orange and white. In addition, all markings should be replaced when faded or otherwise deteriorated below approved SAE AMSSTD595A standards (see Chapter 15).

2.7.2 High-visibility sleeves. It is recommended that several high-visibility sleeves be installed on the meteorological tower outer guy wires (see Figure A-2). One high-visibility sleeve should be installed on each guy wire, as close to the anchor point as possible, but at a height well above the crop or vegetation canopy. A second sleeve should be installed on the same outer guy wires midway between the location of the lower sleeve and the upper attachment point of the guy wire to the meteorological tower.

2.7.3 Spherical markers. It is also recommended that high-visibility aviation orange spherical marker (or cable) balls are attached to the guy wires. Spherical markers should be installed and displayed in accordance with Chapters 3 and 11. The FAA, however, recognizes various weather conditions and manufacturing placement standards may affect the placement and use of high-visibility sleeves and/or spherical markers. Thus, some flexibility is allowed when determining sleeve length and marker placement on the meteorological tower.

3.3 Marking Standards › 3.3.3 Skeletal Structures

CHAPTER 3. MARKING GUIDELINES

3.1 Purpose This chapter provides recommended guidelines to make certain structures conspicuous to pilots during daylight hours. One way to achieve this conspicuity is to paint and/or mark these structures. Recommendations on marking structures can vary, depending on terrain features, weather patterns, geographic location, and the number of structures.

3.2 Marking Colors Alternate sections of aviation orange and white marking should be used as the contrast in colors provides maximum visibility of an obstruction. Specific marking standards are contained in Chapter 15.

3.3 Marking Standards To be effective, the marking used should meet specific color requirements when freshly applied to a structure. Because all outdoor markings deteriorate with time, and it is not practical to give a maintenance schedule for all climates, surfaces should have markings reapplied when the color changes noticeably or its effectiveness is reduced by scaling, oxidation, chipping, or layers of contamination. The subsequent standards should be followed.

3.3.1 Materials and Application The FAA recommends that quality markings (paint, powder coat, vinyl wrap, etc.) and materials be selected to maximize years of service. The marking should be appropriate for the surfaces to be marked, including any previous applications, and suitable for the environmental conditions. Surface preparation and marking application should follow the manufacturer’s recommendations.

Note: In-Service Aviation Orange Color Tolerance Charts are available from private suppliers for determining when repainting is appropriate. The color should be sampled on the upper half of the structure where paint weathering is greater.

3.3.2 Surfaces not Requiring Marking Ladders, decks, and walkways of steel towers and similar structures do not need to be marked if a smooth surface presents a potential hazard to maintenance personnel. Marking may also be omitted from precision or critical surfaces if the marking would have an adverse effect on the transmission or radiation characteristics of a signal. However, the structure’s overall marking effect should not be reduced.

3.3.3 Skeletal Structures Complete all marking/painting prior to or immediately upon completion of construction. This applies to catenary support structures, radio and television towers, and similar skeletal structures. To be effective, marking should be applied to all inner and outer surfaces of the framework.

3.4 Marking Patterns › 3.4.5 Color Band Characteristics

3.4 Marking Patterns Various types of marking patterns are used to distinguish structures. The pattern is determined by the size and shape of the structure. The following patterns are recommended:

3.4.1 Solid Pattern Obstacles should be marked aviation orange if the structure’s horizontal and vertical dimensions do not exceed 10.5 feet (3.20 m).

3.4.2 Checkerboard Pattern Alternating rectangles of aviation orange and white are normally displayed on the following structures:

1. Water, gas, and grain storage tanks (see Figures A-3, A-4, and A-5).

2. Buildings, as required.

3. Large structures exceeding 10.5 feet (3.20 m) across, having a horizontal dimension that is equal to or greater than the vertical dimension.

3.4.3 Size of Patterns The sides of the checkerboard pattern should measure not less than five feet (1.52 m) or more than 20 feet (6.10 m) and should be as nearly square as possible. However, if it is impractical because of the size or shape of a structure, the sides of the patterns may be less than five feet (1.52 m). The pattern should be arranged so that each outer corner of the structure will be painted aviation orange.

3.4.4 Alternate Bands Alternate bands of aviation orange and white are normally displayed on the following structures:

1. Communication towers and catenary support structures.

2. Poles.

3. Smokestacks.

4. Skeletal framework of storage tanks and similar structures.

5. Structures that appear narrow from a side view that are 10.5 feet (3.20 m) or less across, and the horizontal dimension is less than the vertical dimension.

6. Coaxial cable, conduits, and other cables attached to the face of a tower.

7. Wind turbines in snow prone areas may also use off-white (see Chapter 13) for greater conspicuity.

3.4.5 Color Band Characteristics Bands for structures of any height (see Figure A-6) should be:

1. Equal in width, provided each band is not less than 1 1/2 feet (0.46 m) or more than 100 feet (30.48 m) wide.

2. Perpendicular to the vertical axis with the bands at the top and bottom marked orange.

3.4 Marking Patterns › 3.4.8 Partial Marking

3. An odd number of bands on the structure.

4. Equal and in proportion to the structure’s AGL height.

5. Approximately one-seventh the height, if the structure is equal to or less than 700 feet (213.36 m) AGL. For each additional 200 feet (60.96 m) or fraction thereof, add one additional orange and one additional white band. Table 3-1 shows the required band widths based on the height of the structure.

Table 3-1: Structure Height to Bandwidth Ratio

If a structure is: Then Band Width:

Greater Than Equal to or Less Than Band Width

10.5 feet (3.20 m) 700 feet (213.36 m) 1/7 of

700 feet (213.36 m) 900 feet (274.32 m) 1/9 of

900 feet (274.32 m) 1,100 feet (335.28 m) 1/11 of

1,100 feet (335.28 m) 1,300 feet (396.24 m) 1/13 of

3.4.6 Structures With a Cover or Roof If the structure has a cover or roof, the highest orange band should be continued to cover the entire top of the structure (see Figures A-3 and A-4).

3.4.7 Skeletal Structures Atop Buildings If a flagpole, skeletal structure, or similar object is erected on top of a building, the combined height of the object and building will determine whether marking is recommended. However, only the height of the object filed with the FAA determines the width of the color bands.

3.4.8 Partial Marking If marking is recommended for only a portion of a structure because the lower portion of the structure is shielded by other objects or terrain, the width of the bands on the exposed portion should still be determined by the overall height of the structure. Paragraph 3.4.5.5 provides details on calculating the width of the paint bands. A minimum of three bands should be displayed on the exposed portion of the structure. If the exposed portion of the structure is not large enough to have at least three bands, the

Chapter 3. MARKING GUIDELINES › 3.5 Unlighted Markers

width of the bands may be reduced equally so that three equally sized bands can be fit. This will ensure that the marking pattern provides sufficient contrast for a pilot to locate the structure.

3.4.9 Teardrop Pattern Spherical water storage tanks with a single, circular standpipe support may be marked in a teardrop-striped pattern. The tank should show alternate stripes of aviation orange and white. The stripes should extend from the top center of the tank to its supporting standpipe. The width of the stripes should be equal, and the width of each stripe at the greatest girth of the tank should not be less than five feet (1.52 m) nor more than 15 feet (4.57 m) (see Figure A-5).

3.4.10 Community Names If it is desirable to display the name of the community on the side of a tank or other structure, the stripe pattern may be broken to serve this purpose. This open area should have a maximum height of three feet (0.91 m) (see Figure A-5).

3.4.11 Exceptions Structural designs not conducive to standard markings may be marked as follows:

1. If it is not practical to mark the roof of a structure in a checkerboard pattern, it may be marked solid orange.

2. If a spherical structure is not suitable for an exact checkerboard pattern, the shape of the rectangles may be modified to fit the shape of the surface.

3. Storage tanks not suitable for a checkerboard pattern may have alternating bands of aviation orange and white or a limited checkerboard pattern applied to the upper one-third of the structure.

4. The skeletal framework of certain water, gas, and grain storage tanks may be excluded from the checkerboard pattern.

5. Solid spherical water tank stands do not require marking.

3.5 Unlighted Markers Unlighted markers are used to identify structures and to make them more conspicuous when it is impractical to mark them. Unlighted markers may also be used with aviation orange and white markings when additional conspicuity is necessary for aviation safety. Unlighted markers should be displayed in conspicuous positions on or adjacent to the structures to retain the general definition of the structure. They should be recognizable in clear, daytime visibility from a distance of at least 4,000 feet (1,219.20 m) and in all directions from which aircraft are likely to approach. Unlighted markers should be distinctively shaped, i.e., spherical or cylindrical, so that they are not mistaken for items that are used to convey other information. They should be replaced when faded or otherwise deteriorated.

3.5.3 Installation › 3.5.3.4 Adjacent Lines.

3.5.1 Spherical Markers Spherical markers are primarily used to identify overhead wires and catenary transmission lines that are less than 69 kilovolts (kV). Markers may be of another shape, i.e., cylindrical, provided the projected area of such markers is not less than that presented by a spherical marker.

3.5.2 Size and Color The diameter of the markers used on extensive catenary wires (catenary wires that cross canyons, lakes, rivers, etc.) should not be less than 36 inches (91.44 centimeters (cm)). Smaller 20-inch (50.80-cm) spheres are permitted on less extensive catenary wires or on power lines below 50 feet (15.24 m) AGL and within 1,500 feet (457.20 m) of an airport runway end. Each marker should be a solid color, specifically aviation orange, white, or yellow.

3.5.3 Installation

3.5.3.1 Spacing. Unlighted markers should be spaced equally along the wire at approximately 200-foot (60.96 m) intervals, or fraction thereof. There should be less space between markers in critical areas near runway ends (i.e., 30 feet to 50 feet (9.14 m to 15.24 m)). They should be displayed on the highest wire or by another means at the same height as the highest wire. Where there is more than one wire at the highest point, the markers may be installed alternately along each wire if the distance between adjacent markers meets the spacing standard of 200 feet (60.96 m) or less. This method distributes the weight and wind-loading factors (see Figures A-21 and A-24).

3.5.3.2 Pattern. An alternating color scheme provides the most conspicuity against all backgrounds. Unlighted markers should be installed by alternating solid-colored markers of aviation orange, white, and yellow. Normally, an orange marker is placed at each end of a line and the spacing is adjusted (not to exceed 200 feet (60.96 m)) to accommodate the rest of the markers. When less than four markers are used, they should all be aviation orange.

3.5.3.3 Wire Sag. Wire Sag, or droop, will occur due to temperature, wire weight, wind, etc. Twenty-five feet (7.62 m) is the maximum allowable distance between the highest wire installed with marker balls and the highest wire without marker balls and should not violate the sag standards of the transmission line design.

3.5.3.4 Adjacent Lines. Catenary crossings with multiple transmission lines require appropriate markers when the adjacent catenary structure’s outside lines are greater than 200 feet (60.96 m) away from the center of the primary structure. If the outside lines of the adjacent catenary structure are within 200 feet (60.96 m) or less from the center of the primary structure, markers are not required on the adjacent lines.

3.7 Omission or Alternatives to Marking › 3.7.2 Medium Intensity Flashing White Lighting Systems are operated…

3.6 Flag Markers Flags are used to mark certain structures or objects when it is technically impractical to use spherical markers or quality markings (paint, powder coat, vinyl wrap, etc.). Flag markers should be mounted at the highest point of the structure to ensure visibility. Some common examples of structures that may utilize this type of markers include, temporary construction equipment and vehicles, oil and drilling rigs, cranes, and derricks.

3.6.1 Minimum Size Each side of the flag marker should be at least two feet (0.61 m) in length.

3.6.2 Color Patterns Flags should be colored as follows:

1. Solid. Aviation orange.

2. Orange and White. Arrange two triangular sections, one aviation orange, and the other white to form a rectangle.

3. Checkerboard. Flags three feet (0.91 m) or larger should be a checkerboard pattern of aviation orange and white squares, each one foot (0.30 m) plus or minus 10 percent.

4. Shape. Flags should be rectangular in shape and have stiffeners to keep them from drooping in calm wind.

3.6.3 Display. Flag markers should be displayed around, on top, or along the highest edge of the obstruction. When flags are used to mark extensive or closely grouped obstructions, they should be displayed approximately 50 feet (15.24 m) apart. The flag stakes should be strong enough to support the flags and be higher than the surrounding ground, structures, and/or objects of natural growth.

3.7 Omission or Alternatives to Marking The alternatives listed below require FAA review and concurrence prior to making changes. See subsequent chapters for specific guidance.

3.7.1 High Intensity Flashing White Lighting Systems are more effective than aviation orange and white marking and therefore can be recommended instead of paint marking. This is particularly true under certain ambient light conditions involving the position of the sun relative to the direction of flight. High-intensity lighting systems should not be used on structures 700 feet (213.36 m) AGL or less, however, when operated during daytime, twilight, or 24 hours a day, other methods of marking and lighting may be omitted.

3.7.2 Medium Intensity Flashing White Lighting Systems are operated during daytime and twilight on structures 700 feet (213.36 m) AGL or less, but generally not on structures less than 200 feet (60.96 m) AGL. When used, other methods of marking may be omitted.

Note: Note: Sponsors may need to coordinate alternative markings with the FCC for certain structures prior to making any changes.

Chapter 3. MARKING GUIDELINES › 3.8 Unusual Complexities

3.8 Unusual Complexities The FAA may also recommend appropriate marking in an area in which grouped obstructions present a common obstruction to air navigation.

CHAPTER 4. LIGHTING GUIDELINES

4.1 Purpose

This chapter describes the various obstruction lighting systems used to identify structures that have been determined to require added conspicuity. The lighting standards in this Advisory Circular (AC) are the minimum necessary for aviation safety. Recommendations for lighting structures can vary, depending on terrain features, weather patterns, geographic location, and number of structures.

Chapter 4. LIGHTING GUIDELINES › 4.3 Lighting Systems

4.2 Standards

The standards outlined in this A/C are based on using light units that meet specified intensities, beam patterns, color, and flash rates as stated in AC 150/5345-43, Specification for Obstruction Lighting Equipment. The AC may be obtained from: https://www.faa.gov/regulations_policies/advisory_circulars/index.cfm/go/document.inf ormation/documentID/1035508.

4.3 Lighting Systems

All flashing lights on a structure should flash simultaneously except for catenary support structures, which have a distinct flashing sequence between the levels of lights (see paragraph 11.4.2). Obstruction lighting may be displayed on structures as follows (refer to subsequent chapters for details):

1. Aviation Red Obstruction Lights.

Use flashing lights and/or steady-burning lights during nighttime. Tower structures are typically marked with flashing red lights. Buildings and smaller obstructions located near airports should be marked with steady-burning red lights.

2. Medium Intensity Flashing White Obstruction Lights.

Medium intensity flashing white obstruction lights may be used during daytime and twilight with automatic reduced intensity selected for nighttime operation. When this system is used on structures 700 feet (213.36 m) AGL or less, other methods of marking and lighting the structure may be omitted. Aviation orange and white marking is always required for daytime marking on structures exceeding 700 feet (213.36 m) AGL. This system is not normally recommended on structures 200 feet (60.96 m) AGL or less.

3. High Intensity Flashing White Obstruction Lights.

High intensity flashing white obstruction lights may be used during daytime, with automatically selected reduced intensities for twilight and nighttime operations. When this system is used, other methods of marking and lighting the structure may be omitted. This system should not be used on structures 700 feet (213.36 m) AGL or less unless an FAA aeronautical study shows otherwise.

4. Dual Lighting.

This system consists of red lights for nighttime and high- or medium-intensity flashing white obstruction lights for daytime and twilight. When a dual lighting system incorporates medium-intensity flashing white lights on structures 700 feet (213.36 m) AGL or less or high-intensity flashing white lights on structures greater than 700 feet (213.36 m) AGL, other methods of marking the structure may be omitted.

5. Lighted Spherical Markers.

Lighted markers are available for increased night conspicuity of high-voltage (69 kV or greater) transmission line catenary wires and should be manufacturercertified as, visible and recognizable from a minimum distance of 4,000 feet (1,219.20 m) under nighttime conditions and under minimum VFR conditions and have a minimum intensity of at least 32.5 candelas. Markers should be distinctively shaped, i.e., spherical or cylindrical, so that they are not mistaken for items used to convey other information.

6. Aircraft Detection Lighting System.

Lights are controlled by sensor-based systems designed to detect aircraft approaching a single obstacle or group of obstacles and automatically activate the appropriate obstruction lights until the aircraft has departed the area and the lights are no longer needed. This technology reduces the impact of nighttime lighting on nearby communities and migratory birds, as well as extends the life expectancy of obstruction lights.

7. Obstruction Lights During Construction.

As the height of the structure exceeds each level at which permanent obstruction lights would be recommended, two or more lights of the type specified in the determination should be installed at that level. Temporary high- or mediumintensity flashing white lights, if recommended in the determination, should be operated 24 hours a day until all permanent lights are in operation. In either case, two or more lights should be installed on the uppermost part of the structure any time it exceeds the height of the temporary construction equipment. They may be turned off for periods when they could interfere with construction personnel. If practical, permanent obstruction lights should be installed and operated at each level as construction progresses. The lights should be positioned to ensure that a pilot has an unobstructed view of at least one light at each level when approaching from any direction.

8. Obstruction Lights in Urban Areas.

When a structure is located in an urban area where there are numerous other white lights (e.g., streetlights), red obstruction lights with appropriate marking or a medium-intensity dual system is recommended. White lighting is not normally recommended on structures less than 200 feet (60.96 m) or within 3 NM (5.56 km) of an airport.

Chapter 4. LIGHTING GUIDELINES › 4.6 Placement Factors

4.4 Inspection, Repair, and Maintenance

To ensure the proper candela output for fixtures with incandescent lamps, the voltage provided to the lamp filament should not vary more than plus or minus three percent of the lamp’s rated voltage. The input voltage should be measured at the closest disconnecting means to the lamp fixture with the lamp operating during the hours of normal operation (for strobes, the input voltage of the power supplies should be within 10 percent of rated voltage).

Lamps should be replaced after being in operation for approximately 75 percent of their rated life or immediately upon failure.

Flashtubes in a light unit should be replaced immediately upon failure, when the peak effective intensity falls below specification limits, when the fixture begins skipping flashes, or at the manufacturer’s recommended intervals.

Due to the effects of harsh environments, light fixture lenses should be visually inspected every 24 months or when the light fixture fails for ultraviolet (UV) damage, cracks, crazing, dirt buildup, etc., to ensure the certified light output has not deteriorated (see Chapter 2, paragraph 2.4 for reporting requirements in case of failure). Lenses that have cracks, UV damage, crazing, or excessive dirt buildup should be cleaned or replaced.

4.5 Nonstandard Lights

Moored balloons, chimneys, church steeples, teardrop water tanks, and similar obstructions may be floodlighted by fixed search light projectors installed at three or more equidistant points around the base of each obstruction. The searchlight projectors should provide an average illumination of at least 15 foot-candles (161.46 lux) over the top one-third of the obstruction.

4.6 Placement Factors The height above ground level (AGL) of the structure determines the number of light levels. The light levels may be adjusted slightly, but not to exceed 10 feet (3.05 m) when necessary to accommodate guy wires and personnel who replace or repair light fixtures. Except for catenary wire support structures (see Chapter 11), the following factors should be considered when determining the placement of obstruction lights on a structure:

1. Red Obstruction Lighting Systems.

The structure’s overall height, including all appurtenances, such as rods, antennas, and obstruction lights, determines the number of light levels.

2. Medium Intensity Flashing White Obstruction Lighting Systems.

The structure’s overall height, including all appurtenances such as rods, antennas, and obstruction lights, determines the number of light levels.

3. High Intensity Flashing White Obstruction Lighting Systems.

The main structure’s overall height, excluding all appurtenances, such as rods, antennas, and obstruction lights, determines the number of light levels.

4. Dual Obstruction Lighting Systems.

The structure’s overall height, including all appurtenances, such as rods, antennas, and obstruction lights, is used to determine the number of light levels for a mediumintensity white obstruction light/red obstruction dual lighting system. The structure’s overall height, excluding all appurtenances, is used to determine the number of light levels for a high-intensity white obstruction light/red obstruction dual lighting system.

5. Aircraft Lighting Detection System.

The system should be designed with sufficient sensors and mounted with a clear view to provide complete detection coverage for aircraft that enter a threedimensional volume of airspace, or coverage area, around an obstruction(s). The system should activate the obstruction lighting system in sufficient time to allow the lights to illuminate and synchronize to flash simultaneously prior to an aircraft penetrating the defined volume and remain on for a specified time expected for the aircraft to depart the coverage area.

6. Lighted Spherical Markers.

The lighting unit should emit a steady-burning red light and be mounted on the highest energized line, visible to a pilot approaching from any direction. If the lighted markers are installed on a line other than the highest catenary wire, then unlighted markers should be used in addition to the lighted markers and should be installed on the highest energized line. The maximum distance between the line energizing the lighted markers and the highest catenary above the lighted marker should be no more than 25 feet (7.62 m) and should not violate the sag standards of the transmission line design.

7. Adjacent Structures.

The elevation of the tops of adjacent buildings in congested areas may be used as the equivalent of ground level to determine the correct number of light levels required.

8. Shielded Lights.

If an adjacent structure or object blocks the visibility of an obstruction light, the light’s horizontal placement should be adjusted, or additional lights should be mounted on that object to retain or contribute to the definition of the obstruction.

9. Nesting of Lights.

Care should be taken to ensure that obstruction lights do not become blocked or “nested” as new antennas, hardware, or appurtenances are added to the top of a structure. If new equipment is added that blocks the obstruction light’s visibility, the light fixtures should be relocated and/or raised so that it is not blocked by the new equipment. For example, when new larger cellular antenna panels are fitted to

Chapter 4. LIGHTING GUIDELINES › 4.10 Distractions

older towers, the obstruction light should be raised so that it is not blocked by the larger antenna panels. The widest structure, appurtenance, lightning rod, or antenna that can be placed in front of an obstruction light (excluding the L-810 light) without significantly blocking the obstruction light’s visibility should be no wider than 7/8 of an inch. Due to their smaller size, L-810 lights should not be blocked by any structure.

4.7 Monitoring Obstruction Lights Obstruction lighting systems should be closely monitored by visual or automatic means. It is extremely important to visually inspect obstruction lighting in all operating intensities at least once every 24 hours on systems without automatic monitoring. In the event a structure is not readily accessible for visual observation, a properly maintained automatic monitor should be used. This monitor should be designed to register the malfunction of any light on the obstruction regardless of its position or color. When using remote monitoring devices, the system’s communication and operational status should be confirmed at least once every 24 hours. The monitor (aural or visual) should be located in an area generally occupied by the responsible personnel. In some cases, this may require a remote monitor in an attended location. For each structure, a log should be maintained in which the lighting system’s daily operations status is recorded. Light fixture lenses should be replaced if serious cracks, hazing, dirt buildup, etc., has occurred.

4.8 Ice Shields Where icing is likely to occur, metal grates or similar protective ice shields should be installed directly over each light unit to prevent falling ice or accumulation from damaging the light units. The light should be mounted in a manner to ensure an unobstructed view of at least one light by a pilot approaching from any direction.

4.9 Light Shields In general, light shields are not permitted because of the adverse effects they have on the obstruction light fixture’s photometrics. In addition, these shields can promote undesired snow accumulation, bird nesting, and wind loading.

4.10 Distractions When obstruction lights are in proximity to a navigable waterway, they may distract vessel operators. To avoid interference with marine navigation, coordinate with the Office of Navigation Systems, United States (U.S.) Coast Guard before installing the lighting system.

The contact information for the U.S. Coast Guard is:

Commandant (CG-BRG-1) U.S. Coast Guard 2703 Martin Luther King Jr. Avenue, Southeast STOP 7418 Washington, DC 20593-0001 Telephone: 202-815-2101

5.2.2 Double Obstruction Light › 5.2.2.2 Intermediate level

CHAPTER 5. RED OBSTRUCTION LIGHT SYSTEM

5.1 Purpose Red steady burning (L-810) and flashing (L-810 F or L-864) Obstruction Light Systems are used to increase conspicuity during nighttime, however additional marking and/or lighting during daytime and twilight is required. Recommendations on lighting structures can vary, depending on terrain features, weather patterns, geographic location, and number of structures.

5.2 Standards The red obstruction light system is composed of flashing omnidirectional lights (L-864) and/or steady-burning or flashing (L-810/L-810 (F)) lights. When one or more levels are comprised of flashing lights, the lights should flash simultaneously. To determine the number of light levels needed, refer to Figure A-6.

5.2.1 Single Obstruction Light A single red obstruction light may be used when more than one obstruction light is required either vertically or horizontally, or when maintenance is needed, and can be installed within a reasonable time.

5.2.1.1 Top level A single steady-burning light may be used to identify low structures, such as airport instrument landing system buildings, as well as long horizontal structures, such as perimeter fences and building roof outlines.

5.2.1.2 Intermediate level Single flashing or steady-burning lights (as appropriate for size and type of structure) may be used on skeletal and solid structures when more than one level of lights is installed and there are two or more single lights per level.

5.2.2 Double Obstruction Light A double steady-burning light should be installed when used as a top light, at each end of a row of single obstruction lights, and in areas or locations where the failure of a single unit could cause an obstruction to be totally unlighted.

5.2.2.1 Top level Structures 150 feet (45.72 m) AGL or less should have one or more double steady-burning lights installed at the highest point and operating simultaneously.

5.2.2.2 Intermediate level Double flashing or steady-burning lights (as appropriate for size and type of structure) should be installed at intermediate levels when a malfunction

of a single light could create an unsafe condition and in remote areas where immediate maintenance cannot be performed. Both units may operate simultaneously, or a transfer relay may be used to switch to a spare unit should the active system fail.

5.5.1 Top-Mounted Obstruction Lights › 5.5.1.3 Appurtenances 40 feet (12.19 m) or less.

5.2.2.3 Lowest level The lowest level of light units may be installed at a higher elevation than normal on a structure if the surrounding terrain, trees, or adjacent building(s) would obscure the lights. In certain instances, as determined by the FAA, the lowest level of lights may be eliminated.

5.3 Control Device Red obstruction lights should be operated by an acceptable control device (e.g., photocell, timer, etc.) adjusted so the lights will be turned on when the northern sky illuminance reaching a vertical surface falls below a level of 60 foot-candles (645.83 lux) but before reaching a level of 35 foot-candles (376.73 lux). The sensing device should, if practical, face the northern sky in the Northern Hemisphere (see AC 150/5345-43, Specification for Obstruction Lighting Equipment). The control device should turn the lights off when the northern sky illuminance rises to a level of not more than 60 foot-candles (645.83 lux). The lights may also remain on continuously.

5.4 Alternate Method of Displaying Obstruction Lights In certain cases, instead of installing lights on the obstruction, the FAA may recommend the placement of a light(s) on an adjacent pole of equal height.

5.5 Poles, Towers, and Similar Skeletal Structures The following standards apply to radio and television towers, supporting structures for overhead transmission lines, and similar structures.

5.5.1 Top-Mounted Obstruction Lights

5.5.1.1 Structures 150 feet (45.72 m) AGL or less. Two or more steady-burning red (L-810) lights should be installed in a manner to ensure an unobstructed view of one or more lights by a pilot.

5.5.1.2 Structures exceeding 150 feet (45.72 m) AGL. At least one red flashing (L-864) light should be installed in a manner to ensure an unobstructed view of one or more lights by a pilot.

5.5.1.3 Appurtenances 40 feet (12.19 m) or less. If a rod, antenna, or other appurtenance 40 feet (12.19 m) or less in height is incapable of supporting a red flashing light, then it may be placed at the base of the appurtenance. If the mounting location does not allow an

5.5.2 Mounting Intermediate Levels. › 5.5.2.3 Flashing lights (L-864)

unobstructed view of the light by a pilot approaching in any direction, then additional lights should be added.

5.5.1.4 Appurtenances exceeding 40 feet (12.19 m). If a rod, antenna, or other appurtenance exceeding 40 feet (12.19 m) in height is incapable of supporting a red flashing light, a supporting mast with one or more lights should be installed adjacent to the appurtenance. Adjacent installations should not exceed the appurtenance’s height and be within 40 feet (12.19 m) of the tip to allow the pilot an unobstructed view of at least one light. If the rod, antenna, or other appurtenance is 7/8 inch wide or more, at least two lights should be installed on the supporting mast to provide the necessary unobstructed view.

5.5.2 Mounting Intermediate Levels.

The number of light levels is determined by the height of the structure, including all appurtenances, as shown in, Figure A-6. The number of lights on each level is determined by the shape and height of the structure. These lights should be mounted to ensure an unobstructed view of at least one light by a pilot approaching in any direction.

5.5.2.1 Steady-burning lights (L-810)

1. Structures 150 feet (45.72 m) AGL or less.

Two or more steady-burning lights should be installed diagonally or on diametrically opposite positions.

2. Structures exceeding 150 feet (45.72 m) AGL.

These structures do not require steady-burning lights.

5.5.2.2 Flashing lights (L-810 F) For structures exceeding 150 feet (45.72 m) but not more than 350 feet (106.68 m), two or more flashing lights should be mounted outside at diagonally opposite positions at intermediate levels. These lights should be configured to flash simultaneously with the L-864 flashing light on the top of the structure at a rate of 30 flashes per minute (fpm) (± 3 fpm).

5.5.2.3 Flashing lights (L-864)

1. Structures 350 feet (106.68 m) AGL or less.

These structures do not require flashing (L-864) lights at intermediate levels.

2. Structures exceeding 350 feet (106.68 m) AGL.

At intermediate levels, two (L-864) lights should be mounted outside at diagonally opposite positions.

5.6 Chimneys, Flare Stacks, and Similar Solid Structures (except Hyperbolic Cooling Towers)

5.6 Chimneys, Flare Stacks, and Similar Solid Structures (except… › 5.6.3 Mounting Intermediate Levels

5.6.1 Number of Light Units The number of units recommended depends on the diameter of the structure at the top. The number of lights recommended below is the minimum (see Figure A-10).

5.6.1.1 Structures 20 feet (6.10 m) or less in diameter. Three light units per level.

5.6.1.2 Structures exceeding 20 feet (6.10 m) but not more than 100 feet (31 m) in diameter. Four light units per level.

5.6.2 Top-Mounted Obstruction Lights

5.6.2.1 Structures 150 feet (45.72 m) AGL or less. L-810 lights should be installed horizontally at regular intervals at or near the top.

5.6.2.2 Structures exceeding 150 feet (45.72 m) AGL. At least three L-864 lights should be installed.

5.6.2.3 Chimneys, Cooling Towers, and Flare Stacks. Lights may be displayed as low as 20 feet (6.10 m) below the top (Figure A-7) to avoid the obscuring effect of deposits and heat generally emitted by this type of structure. It is important that these lights are readily accessible for cleaning and lamp replacement. It is understood that with flare stacks, as well as any other structures associated with the petrolchemical industry, normal lighting requirements may not be necessary. This could be due to the location of the flare stack/structure within a large, well-lighted, petrol-chemical plant, or the fact that the flare, or working lights surrounding the flare stack/structure, is as conspicuous as obstruction lights.

5.6.3 Mounting Intermediate Levels The number of light levels is determined by the height of the structure including all appurtenances. Structures between 150 feet and 350 feet (45.72 m and 106.68 m) AGL should have a second level of steady-burning red-light units installed approximately at the midpoint of the structure and in a vertical line with the top level of lights. Structures exceeding 350 feet (106.68 m) AGL should have a second level of flashing light units. For cooling towers 600 feet (182.88 m) AGL or less, intermediate light levels are not necessary.

Chapter 5. RED OBSTRUCTION LIGHT SYSTEM › 5.7 Prominent Buildings, Bridges, and Similar Extensive Obstructions

5.6.3.1 Steady-burning (L-810) lights. The recommended number of light levels is shown in Figure A-6. At least three lights should be installed on each level.

5.6.3.2 Flashing (L-864) lights. The recommended number of light levels is shown in Figure A-6.

5.6.3.3 Structures 350 feet (106.68 m) AGL or less. These structures do not need intermediate levels of flashing lights.

5.6.3.4 Structures exceeding 350 feet (106.68 m) AGL. At least three flashing (L-864) lights should be installed on each level in a manner allowing an unobstructed view of at least one light.

5.7 Prominent Buildings, Bridges, and Similar Extensive Obstructions When objects within a group of obstructions are approximately the same overall height above the surface and are located a maximum of 150 feet (45.72 m) apart, the group of obstructions may be considered an extensive obstruction. Light units should be installed on the same horizontal plane at the highest portion, or edge, of the prominent obstructions. Light units should be placed to ensure the light is visible to a pilot approaching from any direction. If the structure is a bridge (see Figure A-8) and is over navigable water, the Sponsor must obtain prior approval of the lighting installation from the Commander of the District Office of the U.S. Coast Guard to avoid interference with marine navigation. Steady-burning lights should be displayed to indicate the extent of the obstruction as follows:

1. Structures 150 feet (45.72 m) or less in any horizontal direction.

If the structure/bridge/ extensive obstruction is 150 feet (45.72 m) or less horizontally, at least one steady-burning light (L-810) should be displayed on the highest point at each end of the obstruction’s major axis. If this is impractical because of the overall shape, display a double obstruction light in the center of the highest point.

2. Structures exceeding 150 feet (45.72 m) in at least one horizontal direction.

If the structure/bridge/extensive obstruction exceeds 150 feet (45.72 m) horizontally, at least one steady-burning light should be displayed for each 150 feet (45.72 m), or fraction thereof, of the overall length of the major axis. At least one of these lights should be displayed on the highest point at each end of the obstruction. Additional lights should be displayed at approximately equal intervals, not to exceed 150 feet (45.72 m) on the highest points along the edge between the end lights. If an obstruction is located near a landing area and two or more edges are the same height, the edge nearest the landing area should be lighted.

Chapter 5. RED OBSTRUCTION LIGHT SYSTEM › 5.8 Group of Obstructions

3. Structures exceeding 150 feet (45.72 m) AGL

Steady-burning red obstruction lights should be installed on the highest point at each end. At intermediate levels, steady-burning red lights should be displayed for each 150 feet (45.72 m), or fraction thereof. The vertical position of these lights should be equidistant between the top lights and the ground level, as the shape and type of obstruction will permit. A steady-burning red light should be displayed at each outside corner on each level with the remaining lights evenly spaced between the corner lights.

4. Exceptions

Flashing red lights (L-864) may be used instead of steady-burning lights if early or special warning is necessary. These lights should be displayed on the highest points of an extensive obstruction at intervals not exceeding 3,000 feet (914.40 m). At least three lights should be displayed on one side of the extensive obstruction to indicate a line of lights.

5. Ice Shields

Where icing is likely to occur, metal grates or similar protective ice shields should be installed directly over each light unit to prevent falling ice or accumulation from damaging the light units. The light should be mounted in a manner to ensure an unobstructed view of at least one light by a pilot approaching from any direction.

5.8 Group of Obstructions With the exception of wind turbines, when individual structures within a group of obstructions differ in height and are spaced no more than 150 feet (45.72 m) apart, the prominent structures within the group should be lighted in accordance with the standards for individual obstructions based on its corresponding height. Shorter structures within the group of obstructions do not need to be lighted based on its corresponding height. When structures are shorter than the prominent structure and are located on the outside of the group of obstructions, those structures should be lighted in accordance with the standards for individual obstructions based on its corresponding height. In addition to lighting the shorter structures on the outside of the group, at least one flashing light should be installed either at the top of the tallest, most prominent center structure, or on a dedicated tower that is located near the center of the group and is the same height as the most prominent structure. Light units should be placed on the structures to ensure that the lights are visible to a pilot approaching from any direction. If one or more of the structures within the group are a solid mass (non-skeletal), additional lighting may be necessary to make sure that the light is not being blocked by the more prominent structure(s). For the purpose of marking and lighting these structures, a group of obstructions is considered to be three or more structures.

Chapter 6. MEDIUM INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS › 6.3 Control Device.

CHAPTER 6. MEDIUM INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS

6.1 Purpose Medium intensity flashing white (L-865) obstruction lights may provide conspicuity both day and night. Recommendations on lighting structures can vary, depending on terrain features, weather patterns, geographic location, and number of structures.

Using a 24-hour, medium intensity, flashing white light system in urban/populated areas is not normally recommended due to their tendency to blend with the background lighting in these areas at night. This makes it extremely difficult for some types of aviation operations, i.e., medical-evacuation (medevac) and police helicopters to see these structures. In addition, to avoid pilot distractions during low-level flight this system is not recommended on structures within 3 NM (5.56 km) of an airport.

6.2 Standards The medium intensity flashing white light system is normally composed of flashing omnidirectional lights. Medium intensity flashing white obstruction lights may be used during daytime and twilight with automatically selected, reduced intensity for nighttime operation. When this system is used on structures 700 feet (213.36 m) AGL or less, other methods of marking and lighting the structure may be omitted, however, structures exceeding 700 feet (213.36 m) AGL always require aviation orange and white marking for daytime. The number of light levels needed is shown in Figure A-9. This system is not normally recommended on structures 200 feet (60.96 m) AGL or less and use in urban and rural areas often results in complaints.

6.3 Control Device. The light intensity is controlled by a device (photocell) that changes the light’s intensity when the ambient light changes. The illuminance sensing device should, if practical, face the northern sky in the Northern Hemisphere and the system should automatically change intensity steps when the illuminance reaching a north-facing vertical surface is as follows:

1. Twilight-to-Night.

This should not occur before the illumination drops below 5 foot-candles (53.82 lux) but should occur before it drops below 2 foot-candles (21.53 lux).

2. Night-to-Day.

The intensity changes listed in subparagraph 6.3.1 above should be reversed when changing from the night-to-day mode.

6.4 Radio and Television Towers and Similar Skeletal Structures. › 6.4.3 Lowest Levels.

6.4 Radio and Television Towers and Similar Skeletal Structures.

6.4.1 Mounting Lights. The number of levels recommended depends on the height of the structure, including antennas and similar appurtenances.

6.4.1.1 Top levels. One or more lights should be installed at the highest point to provide 360degree coverage, ensuring an unobstructed view by a pilot approaching from any direction.

6.4.1.2 Appurtenances 40 feet (12.19 m) or less. If a rod, antenna, or other appurtenance 40 feet (12.19 m) or less in height is incapable of supporting the medium intensity flashing white light, then it may be placed at the base of the appurtenance. If the mounting location does not allow an unobstructed view of the medium intensity flashing white light by a pilot approaching from any direction, then additional lights should be added.

6.4.1.3 Appurtenances exceeding 40 feet (12.19 m). If a rod, antenna, or other appurtenance exceeds 40 feet (12.19 m) above the tip of the main structure, a medium intensity flashing white light should be placed within 40 feet (12.19 m) from the top of the appurtenance. If the appurtenance (such as a whip antenna) is incapable of supporting the light, one or more lights should be mounted on a pole adjacent to the appurtenance. Adjacent installations should not exceed the height of the appurtenance and be within 40 feet (12.19 m) of the tip to allow the pilot an unobstructed view of at least one light. If the rod, antenna, or other appurtenance is 7/8 of an inch wide or more, at least two lights should be installed on the supporting mast to provide the necessary unobstructed view.

6.4.2 Mounting Intermediate Levels. At intermediate levels, two or more lights (L-865) should be mounted outside at diagonally or diametrically opposite positions of intermediate levels. The lowest light level should not be less than 200 feet (60.96 m) AGL.

6.4.3 Lowest Levels. The lowest level of light units may be installed at a higher elevation than normal on a structure if the surrounding terrain, trees, or adjacent building(s) would obscure the lights. In certain instances, as determined by the FAA, the lowest level of lights may be eliminated.

6.6 Prominent Buildings and Similar Extensive Obstructions. › 6.6.1 Structures 150 feet (45.72 m) or less in any horizontal direction.

6.4.4 Structures 700 feet (213.36 m) AGL or less. When medium-intensity flashing white lights are used during nighttime and twilight only, marking is required for daytime. When operated 24 hours a day, other methods of marking and lighting are not required.

6.4.5 Structures exceeding 700 feet (213.36 m) AGL. Medium intensity lights should be used during nighttime, twilight, and may be used 24 hours a day. Additionally, marking is always required for daytime. The number of light levels needed is the same as high intensity lights as shown in Figures A-13 and A-14.

6.4.6 Ice Shields. Where icing is likely to occur, metal grates or similar protective ice shields should be installed directly over each light unit to prevent falling ice or accumulation from damaging the light units. The light should be mounted in a manner to ensure an unobstructed view of at least one light by a pilot approaching from any direction.

6.5 Chimneys, Flare Stacks, and Similar Solid Structures. The recommended number of top-level light units depends on the diameter of the structure at the highest point of a structure. The lights should be installed at the highest point, however, top level chimney lights may be installed as low as 20 feet (6.10 m) below the top to minimize deposit build-up due to emissions (see Figure A-10). The number of lights per level below is the minimum recommended.

1. Structures 20 feet (6.10 m) or less in diameter. Three light units per level.

2. Structures exceeding 20 feet (6.10 m) but not more than 100 feet (31 m) in diameter. Four light units per level.

6.6 Prominent Buildings and Similar Extensive Obstructions. With the exception of wind turbines, when objects within a group of obstructions are approximately the same overall height above the surface and are located a maximum of 150 feet (45.72 m) apart, the group of obstructions may be considered an extensive obstruction. Light units should be installed on the same horizontal plane at the highest portion, or edge, of the prominent obstructions. Light units should be placed to ensure that the light is visible to a pilot approaching from any direction. Lights should be displayed to indicate the extent of the obstruction as follows:

6.6.1 Structures 150 feet (45.72 m) or less in any horizontal direction. If the structure/extensive obstruction is 150 feet (45.72 m) or less horizontally, at least one light should be displayed on the highest point at each end of the obstruction’s major axis. If this is impractical because of the overall shape, display a double obstruction light in the center of the highest point.

Chapter 6. MEDIUM INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS › 6.8 Special Cases.

6.6.2 Structures exceeding 150 feet (45.72 m) in at least one horizontal direction. If the structure/extensive obstruction exceeds 150 feet (45.72 m) horizontally, at least one light should be displayed for each 150 feet (45.72 m), or fraction thereof, of the overall length of the major axis. At least one of these lights should be displayed on the highest point at each end of the obstruction. Additional lights should be displayed at approximately equal intervals not to exceed 150 feet (45.72 m) on the highest points along the edge between the end lights. If an obstruction is located near a landing area and two or more edges are the same height, the edge nearest the landing area should be lighted.

6.6.3 Structures exceeding 150 feet (45.72 m) AGL. Lights should be installed on the highest point at each end. At intermediate levels, lights should be displayed for each 150 feet (45.72 m), or fraction thereof. The vertical position of these lights should be equidistant between the top lights and the ground level as the shape and type of obstruction will permit. One such light should be displayed at each outside corner on each level with the remaining lights evenly spaced between the corner lights.

6.7 Group of Obstructions. With the exception of wind turbines, when individual structures within a group of obstructions differ in height and are spaced no more than 150 feet (45.72 m) apart, the prominent structures within the group should be lighted in accordance with the standards for individual obstructions based on its corresponding height. Shorter structures within the group of obstructions do not need to be lighted. When structures are shorter than the prominent structure and located on the outside of the group of obstructions, those structures should be lighted in accordance with the standards for individual obstructions based on its corresponding height. In addition to lighting the shorter structures on the outside of the group, at least one flashing light should be installed either at the top of the tallest, most prominent center structure, or on a dedicated tower that is located near the center of the group and is the same height as the most prominent structure. Light units should be placed on the structures to ensure that the lights are visible to a pilot approaching from any direction. If one or more of the structures within the group are a solid mass (non-skeletal), additional lighting may be necessary to make sure that the light is not being blocked by the more prominent structure(s). For the purpose of marking and lighting these structures, a group of obstructions is considered to be three or more structures.

6.8 Special Cases. When lighting systems are installed on structures located near highways, waterways, airport approach areas, etc., caution should be exercised to ensure that the lights do not distract or otherwise cause a hazard to motorists, vessel operators, or pilots on an approach to an airport. In these cases, shielding may be necessary and should not derogate the lighting system’s intended purpose.

Chapter 7. HIGH INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS › 7.3 Control Device.

CHAPTER 7. HIGH INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS

7.1 Purpose. High-intensity (L-856) flashing white obstruction lights provide the highest degree of conspicuity both day and night. Recommendations on lighting structures can vary, depending on terrain features, weather patterns, geographic location, and number of structures.

Use extreme caution when using high intensity flashing white lights. Using a 24-hour, high intensity flashing white light system within 3 NM (5.56 km) of an airfield or in urban/populated areas is not normally recommended due to their tendency to merge with background lighting in these areas at night. This makes it extremely difficult for some types of aviation operations (i.e., medevac) and police helicopters to see these structures. Additionally, this type of system in urban and rural areas often results in complaints.

7.2 Standards. High intensity flashing white obstruction lights should be used during daytime with automatically selected, reduced intensities for twilight and nighttime operations. When high-intensity white obstruction lights are operated 24 hours a day, other methods of marking and lighting may be omitted. This system should not be on structures 700 feet (213.36 m) AGL or less unless an FAA aeronautical study shows otherwise. The number of light levels needed is shown in Figures A-13 and A-14.

7.3 Control Device. Light intensity is controlled by a device (photocell) that changes the light’s intensity when the ambient light changes. The illuminance sensing device should, if practical, face the northern sky in the Northern Hemisphere and the system should automatically change intensity steps when the illuminance reaching a north-facing vertical surface is as follows:

1. Day-to-twilight.

This should not occur before the illumination drops to 60 foot-candles (645.83 lux) but should occur before it drops below 35 foot-candles (376.74 lux).

2. Twilight-to-night.

This should not occur before the illumination drops below 5 foot-candles (53.82 lux) but should occur before it drops below 2 foot-candles (21.53 lux).

3. Night-to-day. The intensity changes listed in subparagraphs 7.3.1 and 7.3.2 above should be reversed when changing from the night-to-day mode.

7.5 Installation Guidance. › 7.5.1 Vertical Aiming.

Height of Light Unit Above TerrainDegrees of Elevation Above

Exceeding 500 feet AGL 0°

Above 400 feet to 500 feet AGL 1°

Above 300 feet to 400 feet AGL 2°

300 feet AGL or less 3°

7.4 Units per Level. One or more light units are needed to obtain the desired horizontal coverage. The number of light units recommended per level (except for the supporting structures of catenary wires and buildings) depends upon the average outside diameter of the specific structure and the horizontal beam width of the light fixture. Light units should be installed to ensure an unobstructed view of the system by a pilot approaching from any direction. The number of lights recommended below is the minimum.

1. Structures 20 feet (6.10 m) or less in diameter. Three light units per level.

2. Structures exceeding 20 feet (6.10 m) but not more than 100 feet (30.48 m) in diameter. Four light units per level.

3. Structures exceeding 100 feet (30.48 m) in diameter. Six light units per level.

4. Structures exceeding 200 feet (60.96 m) in diameter. Eight light units per level.

7.5 Installation Guidance. On most obstruction high-intensity light fixtures, the effective peak intensity of the light beam can be adjusted from zero-to-eight degrees above the horizon. Standard installation should place the top light at zero degrees to the horizontal and all other light units installed in accordance with Table 7-1.

Table 7-1 Light Unit Elevation Above the Horizontal

7.5.1 Vertical Aiming. When terrain, nearby residential areas, or other situations dictate, the light beam may be further elevated above the horizontal. The main beam of light at the lowest level should not strike the ground closer than 3 SM (4.83 kilometers (k)) from the structure. If additional adjustments are necessary, the lights may be individually adjusted upward, in

7.6 Radio and Television Towers and Similar Skeletal Structures. › 7.6.1 Mounting Lights.

one-degree increments, starting at the bottom. Excessive elevation may reduce conspicuity by raising the beam above a collision course flight path.

7.5.2 Relocation or Omission of Light Units. Light units should not be installed in such a manner that the light pattern/output is disrupted by the structure.

7.5.2.1 Lowest Level. The lowest level of light units may be installed at a higher elevation than normal on a structure if the surrounding terrain, trees, or adjacent building(s) would obscure the lights. In certain instances, as determined by the FAA, the lowest level of lights may be eliminated.

7.5.2.2 Two Adjacent Structures. When two structures are within 500 feet (152.40 m) of each other and the light units are installed at the same levels, the sides of the structures facing each other do not need be lighted (see Figures A-11 and A-12). However, all lights on both structures must flash simultaneously, except for adjacent catenary support structures (see paragraph 11.4). Vertical placement of the lights should be adjusted to either or both structures’ intermediate levels to place the lights on the same horizontal plane. If one structure is higher than the other, a complete level of lights should be installed on the higher structure that extends above the top of the lower structure. If the structures are of such heights that the levels of lights cannot be placed in identical horizontal planes, then the light units should be placed so that the center of the horizontal beam patterns do not face toward the adjacent structure. For example, structures situated north and south of each other should have the light units on both structures installed on a northwest/southeast and northeast/southwest orientation.

7.5.2.3 Three or More Adjacent Structures. The treatment of a cluster of structures as an individual or a complex of structures will be determined by the FAA, taking into consideration the location, heights, and spacing of other structures.

7.6 Radio and Television Towers and Similar Skeletal Structures.

7.6.1 Mounting Lights. The number of levels recommended depends on the height of the structure, excluding antennas and similar appurtenances. At least three lights should be installed on each level and mounted to ensure that the effective intensity of the full horizontal beam coverage is not impaired by the structural members.

Chapter 7. HIGH INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS › 7.9 Prominent Buildings and Similar Extensive Obstructions.

7.6.2 Top Level. One level of lights should be installed at the highest point of the structure. If the highest point is a rod or antenna incapable of supporting a lighting system, then the top level of lights should be installed at the highest portion of the main skeletal structure. If guy wires come together at the top, it may be necessary to install this level of lights as low as 10 feet (3.05 m) below the top. If the appurtenance (rod, antenna, etc.) exceeds 40 feet (12.19 m) above the main structure, a medium-intensity, flashing white light (L­ 865) should be mounted on the highest point (see Figure A-7). If the appurtenance (such as a whip antenna) is incapable of supporting a medium-intensity light, one or more lights should be installed on a pole adjacent to the appurtenance. The pole should not exceed the height of the appurtenance and no lower than 40 feet (12.19 m) from the top, allowing a pilot an unobstructed view of at least one light in any direction. If the pole, rod, antenna, or other appurtenance is 7/8 of an inch wide or more, at least two lights should be installed on the supporting mast to provide the necessary unobstructed view.

7.6.3 Ice Shields. Where icing is likely to occur, metal grates or similar protective ice shields should be installed directly over each light unit to prevent falling ice or accumulation from damaging the light units. The light should be mounted in a manner to ensure an unobstructed view of at least one light by a pilot approaching from any direction.

7.7 Antenna or Similar Appurtenance Light. When a structure lighted by a high-intensity, flashing white light system is topped with an antenna or similar appurtenance exceeding 40 feet (12.19 m) in height, a mediumintensity flashing white light (L-865) should be placed within 40 feet (12.19 m) from the tip of the appurtenance. This light should operate 24 hours a day and flash simultaneously with the rest of the lighting system. The location of the appurtenance light is shown in, Figure A-14. Structures with an appurtenance 40 feet (12.19 m) or less in height should be lit in accordance with Figure A-13.

7.8 Chimneys, Flare Stacks, and Similar Solid Structures. The number of light levels depends on the height of the structure, excluding appurtenances. Three or more lights should be installed on each level to ensure an unobstructed view by the pilot. Normally, the top-level lights are on the highest point of a structure, however, top level chimney lights may be installed as low as 20 feet (6.10 m) below the top to minimize deposit buildup due to emissions.

7.9 Prominent Buildings and Similar Extensive Obstructions. When objects within a group of obstructions are approximately the same overall height above the surface and are located a maximum of 150 feet (45.72 m) apart, the group of obstructions may be considered an extensive obstruction. Light units should be placed to ensure that the light is visible to a pilot approaching from any direction. These lights may require shielding, such as louvers, to ensure minimum adverse impact on local

Chapter 7. HIGH INTENSITY FLASHING WHITE OBSTRUCTION LIGHT SYSTEMS › 7.11 Special Cases.

communities. Light units should be installed on the same horizontal plane at the highest portion or edge of the prominent obstructions and displayed to indicate the extent of the obstruction as follows:

7.9.1 Obstructions 200 feet (60.96 m) or less in either horizontal dimension. Three or more light units should be installed at the highest portion of the structure to ensure that at least one light is visible to a pilot approaching from any direction. Light units may be mounted on a single pedestal at or near the center of the obstruction. If the light units are placed more than 10 feet (3.05 m) from the center point of the structure, use a minimum of four light units.

7.9.2 Obstruction exceeds 200 feet (60.96 m) in one horizontal dimension but is 200 feet (60.96 m) or less in the other. Two light units should be placed on each of the shorter sides. These light units may be installed either adjacent to each other at the midpoint of the obstruction’s edge or at (near) each corner, with the light unit aimed to provide 180 degrees of coverage at each edge. One or more light units should be installed along the overall length of the major axis at approximate equal intervals, not to exceed a distance of 100 feet (30.48 m) from the corners or from each other.

7.9.3 Obstruction exceeds 200 feet (60.96 m) in both horizontal dimensions. The light units should be equally spaced along the overall perimeter of the obstruction at intervals of 100 feet (30.48 m), or fraction thereof.

7.10 Hyperbolic Cooling Towers. High intensity light units should be installed to ensure an unobstructed view of at least two lights by a pilot approaching from any direction.

7.10.1 Number of light units. The number of units recommended depends on the diameter of the structure at the top, as shown in Figure A-15. The minimum number of light units recommended is indicated below.

1. Structures exceeding 100 feet (30.48 m) but not more than 200 feet (60.96 m) diameter. Six light units per level.

2. Structures exceeding 200 feet (60.96 m) in diameter. Eight light units per level.

7.11 Special Cases. When lighting systems are installed on structures located near highways, waterways, airport approach areas, etc., caution should be exercised to ensure that the lights do not distract or otherwise cause a hazard to motorists, vessel operators, or pilots on an approach to an airport. In these cases, shielding or adjusting the aim of the vertical or horizontal light may be necessary. This adjustment should not derogate the lighting

system’s intended purpose. Such adjustments may require an additional review, as described in paragraph 7.5.

Chapter 8. › 8.4 Control Device.

CHAPTER 8. DUAL LIGHTING WITH RED/MEDIUM INTENSITY FLASHING WHITE LIGHT

SYSTEMS

8.1 Purpose. This dual lighting system includes red lights (L-864) for nighttime and mediumintensity flashing white lights (L-865) for daytime and twilight use. This lighting system may be used in lieu of operating a medium intensity flashing white lighting system at night. There may be some populated areas where nighttime use of mediumintensity light systems may cause significant environmental concerns. Using the dual lighting system should reduce/mitigate those concerns and complaints. Recommendations for lighting structures can vary, depending on terrain features, weather patterns, geographic location, and number of structures.

8.2 Installation. The light units should be installed as specified in Chapters 4, 5, and 6 of this advisory circular. The number of light levels needed is dependent on the height of the obstruction, as shown in Figure, A-16.

8.3 Operation. Light systems should be operated as specified in Chapters 4, 5, and 6. These systems should not be operated simultaneously; however, there should be no more than a 2second delay when changing from one system to the other. Outage of the uppermost red light should activate the white obstruction light system and operate in its specified “night” step intensity.

8.4 Control Device. The light system is controlled by a device (photocell) that changes the intensity of the lights when the ambient light changes. The illuminance sensing device should, if practical, face the northern sky in the Northern Hemisphere and the system should automatically change intensity steps when the illuminance reaching a north-facing vertical surface is as follows:

1. Twilight-to-Night.

This should not occur before the illumination drops below 5 foot-candles (53.82 lux) but should occur before it drops below 2 foot-candles (21.53 lux).

2. Night-to-Day.

The intensity changes listed in subparagraph 8.4.1 above should be reversed when changing from the night-to-day mode.

8.6 Mounting Lights › 8.6.3 When a structure equipped with a dual lighting system is topped…

8.5 Antenna or Similar Appurtenance Light.

8.5.1 When a structure equipped with a dual lighting system is topped with an antenna or similar appurtenance exceeding 40 feet (12.19 m) in height, a medium-intensity flashing white (L-865) and a flashing red light (L-864) should be placed within 40 feet (12.19 m) from the tip of the appurtenance. The white light should operate during daytime and twilight and the red light during nighttime. These lights should flash simultaneously with the rest of the lighting system.

8.5.2 When a structure equipped with a dual lighting system is topped with an antenna or similar appurtenance less than 40 feet (12.19 m) in height and exceeds 7/8 of an inch, a minimum of two medium-intensity flashing white (L-865) and flashing red lights (L­ 864) should be placed immediately below, within 40 feet (12.19 m) from the tip of the appurtenance (see Figure A-17). The white light should operate during daytime and twilight and the red light between the hours of sunset and sunrise. These lights should flash simultaneously with the rest of the lighting system.

8.6 Mounting Lights The number of levels recommended depends on the height of the structure, including antennas and similar appurtenances.

8.6.1 Top levels. One or more lights should be installed at the highest point to provide 360-degree coverage, ensuring an unobstructed view by a pilot approaching from any direction.

8.6.2 Appurtenances 40 feet (12.19 m) or less. When a structure equipped with a dual lighting system is topped with an antenna or similar appurtenance less than 40 feet (12.19 m) in height and exceeds 7/8 of an inch, a minimum of two medium-intensity flashing white (L-865) and flashing red lights (L­ 864) should be placed immediately below, within 40 feet (12.19 m) from the tip of the appurtenance (see Figure A-17). The white lights should operate during daytime and twilight and the red light between the hours of sunset and sunrise. These lights should flash simultaneously with the rest of the lighting system. If a rod, antenna, or other appurtenance 40 feet (12.19 m) or less in height is incapable of supporting the dual lighting system, then it may be placed at the base of the appurtenance. If the mounting location does not allow an unobstructed view by a pilot approaching from any direction, then additional lights should be added.

8.6.3 When a structure equipped with a dual lighting system is topped with an antenna or similar appurtenance exceeding 40 feet (12.19 m) in height, a medium-intensity flashing white (L-865) and a flashing red light (L-864) should be placed within 40 feet (12.19 m) from the tip of the appurtenance. The white light should operate during daytime and twilight and the red light during nighttime. These lights should flash simultaneously with the rest of the lighting system. If the appurtenance (such as a whip antenna) is incapable of supporting the light, one or more lights should be mounted on a pole adjacent to the appurtenance. Adjacent installations should not exceed the height of the

Chapter 8. › 8.7 Omission of Marking

appurtenance and be within 40 feet (12.19 m) of the tip to allow the pilot an unobstructed view of at least one light. If the rod, antenna, or other appurtenance is 7/8 of an inch wide or more, at least two lights should be installed on the supporting mast to provide the necessary unobstructed view.

8.6.4 Mounting Intermediate Levels. At intermediate levels, two or more lights (L-864/L-865) should be mounted outside at diagonally or diametrically opposite positions of intermediate levels. The lowest light level should not be less than 200 feet (60.96 m) AGL.

8.6.5 Lowest Levels. The lowest level of light units may be installed at a higher elevation than normal on a structure if the surrounding terrain, trees, or adjacent building(s) would obscure the lights. In certain instances, as determined by the FAA, the lowest level of lights may be eliminated.

8.7 Omission of Marking When medium intensity white obstruction lights are operated on structures 700 feet (213.36 m) AGL or less during daytime and twilight, other methods of marking may be omitted.

Continue reading ↓ 120 of 204 passages shown