Radar Vectors
Advisory Circular Cancelled Issued Jul 15, 1991 ANM-110 176 pages Copy saved Nov 18, 2026

AC 25-17 [Large AC] Transport Airplane Cabin Interiors Crashworthiness Handbook

This Advisory Circular (AC) provides acceptable certification methods, but not necessarily the only acceptable methods, for demonstrating compliance with the crashworthiness requirements of part 25, as amended through Amendment 25-112, of Title 14 of the Code of Federal Regulations (14 CFR) for transport category airplanes. The guidance in this AC is not mandatory nor a regulation

This document is cancelled. Cancelled by 25-17A. Check the official source before relying on it.

Official source ↗ Open PDF

U.S. Department of Transportation

Federal Aviation Administration

Advisory Circular

AC: 25-17

DATE: 7/15/91

TRANSPORT AIRPLANE CABIN INTERIORS

CRASHWORTHINESS HANDBOOK

U.S. Deportment of Transportation Federal Aviation Administration

Advisory Circular

Subjec:t:TRANSPORT AIRPLANE CABIN INTERIORS Date: 7 /15/91 AC No: 25-17 Change: CRASHWORTHINESS HANDBOOK Initiated by: ANM-110

CRASHWORTHINESS HANDBOOK

1. PURPOSE. This Advisory Circular (AC) provides acceptable certification methods, but not necessarily the only acceptable methods, for demonstrating

compliance with the crashworthiness requirements of Part 25 of the Federal Aviation Regulations (FAR) for transport category airplanes. The guidance in this AC is not mandatory nor a regulation.

2. BACKGROUND.

a. Crashworthiness, as applied to airplane cabin interiors, denotes the incorporation in basic design of considerations pertinent to the protection of airplane occupants in a "survivable crash environment." A "survivable" crash environment prevails when the cabin occupants are subjected to crash forces within human tolerance levels, and the structural integrity of the passenger space remains intact such that the occupants can rapidly evacuate the airplane. Structural design for airplane safety has embodied airworthiness and crashworthiness design objectives to varying degrees. Airworthiness design objectives pertain to the ability of the airframe to withstand design loads, or to maintain safety of flight of the airplane relative to the operational environment. Crashworthiness design objectives pertain to safety of the occupants relative to the airplane. Some aspects of crashworthiness, e.g., fuel tank/system design, fuselage deformation ,and prevention of post-crash fires, are beyond the scope of this AC.

b. Since inception of federal civil aircraft certification standards, . prime emphasis has focused on design for airworthiness, with a preference for application of static load tests, as opposed to dynamic. The emphasis on airworthiness is understandable, since structural and handling deficiencies were inherent in early airplane designs. Further, there was not enough

theoretical or technical knowledge available from servi~e experience to generate meaningful design parameters for crash survival. Likewise, in early design, as now, dynamic criteria have been difficult to ascertain. Except for standards for seat belts, seat static load requirements and exits, crashworthiness was given very little attention until the post World War II period. During subsequent years, emphasis on crashworthiness was expanded by the regulatory process. A significant change occurred in 1967, when the Federal Aviation Administration (FAA) promulgated a series of crashworthiness standards affecting transport category airplanes. Further changes were

implemented in 1972. As reflected in the rule changes of 1967, the FAA's approach to crashworthiness principally involved three areas of concern: (1) protection of airplane occupants from crash impact; (2) minimizing development and severity of potential crash fire; and (3) rapid evacuation of airplane

For sale by the U.S. Government Printing Office Superintendent of Documents, Mail Stop: SSOP, Washington, DC 20402-9328

ISBN 0-16-035902-3

occupants. Each of these factors has been a focal point in the periodic upgrading of regulatory standards. · ·

c. Part 4b of the former Civil Air Regulations (CAR) was recodified in 1965 as Part 25 of the FAR. The related policy material contained in Civil Aeronautics Manual (CAM) 4b was applicable to Part 25 as originally recodified

and to current Part 25 except in areas that have been amended since recodification. Those policies are included in this AC and listed as guidance applicable to the original recodified version of Part 25.

d. This AC consists of the original Part 25 of the FAR (1965 recodified version), followed by appropriate guidance. Amendments to the regulation are presented in chronological order, with only those paragraphs changed by the amendment reprinted. If additional guidance exists for an amended rule, it is presented following the amended paragraphs. Unless otherwise noted, guidance for the basic rule ·applies to amended versions of the rule as· well. Additionally, guidance for an amendment will apply to later amendments, unless

otherwise noted. Regulations for which no guidance is presently available are listed as [RESERVED].

e. Certain changes, such as an increase in passenger seating capacity or the airplane operating rules, may require compliance with rules later than the type certification basis. Refe.r to §§ 21.lOl(a), 25.2, 91.58, 121.310, 121.311, 121.312, 121.317, 121.318, 121.319, 125.113, 135.170, and Appendix A of Part 135 of the FAR.

f. Advisory circulars listed in Appendix 3 may be revised after issuance of this AC. The latest available revision of the listed AC should be used.

3. APPLICABILITY. Available guidance pertaining to Part 25 is presented according to the amendment .level of Part 25 to which it applies. For modified airplanes certificated under Part 25, the pertinent guidance may be obtained from this AC by reference to the applicable amendment level. (Compliance with later rules may be required in accordance with§§ 21.lOl{a) and 25.2 or with applicable operating rules as noted above.) The guidance presented in this AC for Part 25 airplanes may be used for airplanes certificated under CAR 4b to the extent the rules contained in the older certification bases are the same as those of Part 25. The guidance presented herein applies to Part 25 through Amen(/ 25-59. . I} /) ~ ~"c CJ-.·1lJ,C

LEROY A. KEITH Manager, Transport Airplane Directorate Aircraft Certification Service, ANM-100

II

TABLE OF CONTENTS

TABLE OF CONTENTS

Paragraph

1-40. [RESERVED]

SECTION 25.772 PILOT COMPARTMENT DOORS

41. Section 25.772 Did Not Exist Prior to Amendment 25-33. 42. Amendment 25-33, Effective·October 21, 1972. 43. Amendment.25-47, Effective December 24, 1979. 44-60. [RESERVED] .

SECTION 25.783 DOORS

SECTION 25.783 DOORS

61. Regulation in Effect at Adoption of Part 25. 62. Amendment 25-15, Effective October 24, 1967. 63. Amendment 25-23, Effective May 8, 1970. 64. Amendment 25-54, Effective October 14, 1980. 65-80. [RESERVED]

81. 82. 83. 84. 85. 86-100.

SECTION 25.785 SEATS, BERTHS, SAFETY BELTS, AND HARNESSES

SECTION 25.785 SEATS, BERTHS, SAFETY BELTS, AND HARNESSES

Regulation in Effect at Adoption of Part 25. Amendment 25-15, Effective October 24, 1967. Amendment 25-20, Effective April 23, 1969. Amendment 25-32, Effective· May 1, 1972. Amendment 25-51, Effective March 6, 1980.

[RESERVED]

SECTION 25.787 STOWAGE COMPARTMENTS

101. Regulation in Effect at Adoption of Part 25. 102. Amendment 25-32, Effective May 1, 1972. 103. Amendment 25-38, Effective February 1, 1977. 104. Amendment 25-51, Effective March 6, 1980. 105-120. [RESERVED]

SECTION 25.789 RETENTION OF ITEMS OF MASS

SECTION 25.789 RETENTION OF ITEMS OF MASS

121. Section 25.789 Did Not Exist Prior to Amendment 25-32. 122. Amendment 25-32, Effective May 1, 1972. 123. Amendment 25-46, Effective December 1, 1978. 124-140. [RESERVED]

AC 25-17

Page

1

51 51 51 52

101 104 104 105 106

201 205 205 206 206 208

301 301 303 304 304

321 321 321 321

III

SECTION 25.791 PASSENGER INFORMATION SIGNS

SECTION 25.791 PASSENGER INFORMATION SIGNS

141. Section 25.791 Did Not Exist Prior to Amendment 25-32. 361 142. Amendment 25-32, Effective May 1, 1972. 361 143-160. [RESERVED] 361

SECTION 25.793 FLOOR SURFACES

161. Section 25.793 Did Not Exist Prior to Amendment 25-51. 381 162. Amendment 25-51, Effective March 6, 1980. 381 163-250. [RESERVED] 381

SECTION 25.801 DITCHING

SECTION 25.801 DITCHING

251. Regulation in Effect at Adoption of Part 25. 252-270. [RESERVED]

SECTION 25.803 EMERGENCY EVACUATION

271. Regulation i~ Effect at Adoption of Part 25. 272. Amendment 25-1, Effective June 7, 1965. 273. Amendment 25-15, Effective October 24, 1967. 274. Amendment 25-17, Effective June 20, 1968. 275. Amendment 25-20, Effective April 23, 1969. 276. Amendment 25-32, Effective May 1, 1972. 277. Amendment 25-46, Effective December 1, 1978. 278-300. [RESERVED]

SECTION 25.805 FLIGHT CREW EMERGENCY EXITS

SECTION 25.805 FLIGHT CREW EMERGENCY EXITS

301. Regulation in Effect at Adoption of Part 25. 302-320. [RESERVED]

SECTION 25.807 PASSENGER EMERGENCY EXITS

321. Regulation in Effect at Adoption of Part 25. 322. Amendment 25-15, Effective October 24, 1967. 323. Amendment 25-32, Effective May 1, 1972. 324. Amendment 25-39, Effective February 10, 1977. 325. Amendment 25-46, Effective February 11, 1978. 326. Amendment 25-55, Effective April 28, 1982. 327-350. [RESERVED]

SECTION 25.807 PASSENGER EMERGENCY EXITS

IV

401 403

451 451 451 455 456 456 456 459

501 501

521 524 530 532 533 533 534

SECTION 25.809 EMERGENCY EXIT ARRANGEMENT

351. Regulation in Effect at Adoption of Part 25. 352. Amendment 25-1, Effective June 7, 1965. 353. Amendment 25-9, Effective June 30, 1966. 354. Amendment 25-15, Effective October 24, 1967. 355. Amendment 25-32, Effective May 1, 1972. 356. Amendment 25-34, Effective December 31, 1972. 357. Amendment 25-46, Effective December 1, 1978. 358. Amendment 25-47, Effective December 24, 1979. 359-380. [RESERVED]

SECTION 25.811 EMERGENCY EXIT MARKING

SECTION 25.811 EMERGENCY EXIT MARKING

381. Regulation in Effect at Adoption of Part 25. 382. Amendment 25-1, Effective June 7, 1965. 383. Amendment 25-15, Effective October 24, 1967. 384. Amendment 25-32, Effective May 1, 1972. 385. Amendment 25-46, Effective December 1, 1978. 386-390. [RESERVED]

SECTION 25.812 EMERGENCY LIGHTING

SECTION 25.812 EMERGENCY LIGHTING

601 603 603 603 605 607 607 608 609

651 651 654 656 657 658

391. Section 25.812 Did Not Exist Prior to Amendment 25-15. 681 392. Amendment 25-15, Effective October 24, 1967. 681 393. Amendment 25-28, Effective September 25, 1971. 685 394. Amendment 25-32, Effective May 1, 1972. 685. 395. Amendment 25-46, Effective December 1, 1978. 688 396. Amendment 25-58, Effective November 26, 1984. 689 397-410. [RESERVED] 689

SECTION 25.813 EMERGENCY EXIT ACCESS

SECTION 25.813 EMERGENCY EXIT ACCESS

411. Regulation in Effect at Adoption of Part 25. 412. Amendment 25-1, Effective June 7, 1965. 413. Amendment 25-15, Effective October 24, 1967. 414. Amendment 25-17, Effective June 20, 1968. 415. Amendment 25-32, Effective May 1, 1972. 416. Amendment 25-46, Effective December 1, 1978. 417-440. [RESERVED] .

SECTION 25.815 WIDTH OF MAIN AISLE

SECTION 25.815 WIDTH OF MAIN AISLE

441. Regulation in Effect at Adoption of Part 25. 442. Amendment 25-15, Effective October 24, 1967. 443. Amendment 25-38, Effective February 1, 1977. 444-460. [RESERVED]

SECTION 25.817 MAXIMUM NUMBER OF SEATS ABREAST

461-480. [RESERVED].

721 724 725 726 726 727 727

SECTION 25.817 MAXIMUM NUMBER OF SEATS ABREAST

761 762 762 763

781

V

AC 25-17

SECTION 25.819 LOWER DECK SERVICE COMPARTMENTS

(INCLUDING GALLEYS}

481. Section 25.819 Did Not Exist Prior to Amendment 25-53. 801 482. Amendment 25-53, Effective·August 31, 1980. 801 483-600. [RESERVED] 802

SECTION 25.851 FIRE EXTINGUISHERS

601. Regulation in Effect at Adoption of Part 25. 602. Amendment 25-54, Effective October 14, 1980. 603-620 .. [RESERVED]

SECTION 25.853 COMPARTMENT INTERIORS

SECTION 25.853 COMPARTMENT INTERIORS

621. Regulation in Effect at Adoption of Part 25. 622. Amendment 25-15, Effective October 24, 1967. 623. Amendment 25-17, Effective June 20, 1968·. 624. Amendment 25-23, Effective May 8, 1970. 625. Amendment 25-32, Effective May I, 1972. 626. Amendment 25-51, Effective March 6, 1980. 627. Amendment 25-59, Effective November 26, 1984. 628-650. [RESERVED]

SECTION 25.855 CARGO AND BAGGAGE COMPARTMENTS

SECTION 25.855 CARGO AND BAGGAGE COMPARTMENTS

651. Regulation in Effect at Adoption of Part 25. 652. Amendment 25-15, Effective October 24, 1967. &53. Amendment 25-32, Effective May 1, 1972: 654-670. [RESERVED]

SECTION 25.857 CARGO COMPARTMENT CLASSIFICATION

671. Regulation in Effect at Adoption of Part 25. 672. Amendment 25-32, Effective May 1, 1972. 673-750. [RESERVED]

SECTION 25.1307 MISCELLANEOUS EQUIPMENT

SECTION 25.1307 MISCELLANEOUS EQUIPMENT

751. Regulation in Effect at Adoption of Part 25. 752. Amendment 25-23, Effective May 8, 1970. 753. Amendment 25-46, Effective December 1, 1978. 754. Amendment 25-54, Effective October 14, 1980. 755-780. [RESERVED]

VI

901 903 904

931 941 942 944 944 946 947 947

1001 1001 1002 1003

1051 1054 1056

1101 1101 1102 1103

SECTION 25.1359 ELECTRICAL SYSTEM FIRE AND SMOKE

SECTION 25.1359 ELECTRICAL SYSTEM FIRE AND SMOKE

PROTECTION

781. Section 25.1359(d) Did Not Exist Prior to Amendment 25-32. 1151 782. Amendment 25-32, Effective May 1, 1972. 1151 783-800. [RESERVED] 1151

SECTION 25.1411 SAFETY EQUIPMENT - GENERAL

801. Regulation in Effect at Adoption of Part 25. 802. Amendment 25-32, Effective May I, 1972. 803. Amendment 25-46, Effective December 1, 1978. 804. Amendment 25-53, Effective August 31, 1980. 805-820. [RESERVED]

SECTION 25.1413 SAFETY BELTS

SECTION 25.1413 SAFETY BELTS

821 .. Regulation in Effect at Adoption of Part 25. 822. Amendment 25-44, Effective December 4, 1978. 823. Amendment 25-51, Effective March 8, 1980. 824-840. [RESERVED]

SECTION 25.1415 DITCHING EQUIPMENT

841. Regulation in Effect at Adoption of Part 25. 842. Amendment 25-29, Effective October 21, 1971. 843. Amendment 25-52, Effective September 9, 1980. 844-880. [RESERVED]

SECTION 25.1421 MEGAPHONES

SECTION 25.1421 MEGAPHONES

881-920. [RESERVED]

SECTION 25.1439 PROTECTIVE BREATHING EQUIPMENT

921-970. [RESERVED]

SECTION 25.1447 EQUIPMENT STANDARDS FOR OXYGEN

DISPENSING UNITS

971. Regulation in Effect at Adoption of Part 25. 972. Amendment 25-41, Effective September 1, 1977. 973-1010. [RESERVED]

SECTION 25.1451 FIRE PROTECTION FOR OXYGEN

SECTION 25.1451 FIRE PROTECTION FOR OXYGEN

EQUIPMENT

1011. Regulation in Effect at Adoption of Part 25. 1012-1040. [RESERVED]

1201 1202 1203 1204 1204

1251 1251 1251 1252

1281 1283 1283 1283

1321

1341

1401 1403 1404

1451 1451

VII

AC 25-17

SECTION 25.1541 MARKINGS AND PLACARDS - GENERAL

SECTION 25.1541 MARKINGS AND PLACARDS - GENERAL

1041. Regulation in Effect at Adoption of Part 25. 1042-1080. [RESERVED] .

SECTION 25.1557(a}, (c), and (d) MISCELLANEOUS

MARKINGS AND PLACARDS

1081-1100. [RESERVED]

SECTION 25.1561 SAFETY EQUIPMENT

1101. Regulation in Effect at Adoption of Part 25. 1102. Amendment 25-46, Effective December 1, 1978. 1103-1150. [RESERVED]

APPENDIX F. ACCEPTABLE PROCEDURES FOR

APPENDIX F. ACCEPTABLE PROCEDURES FOR

FLAMMABILITY TESTING FOR COMPLIANCE WITH

SECTIONS 25.853, 25.855, AND 25.1359

1151. Appendix F Did Not Exist Prior to Amendment 25-15. 1152. Amendment 25-15, Effective October 24, 1967. 1153. Amendment 25-32, Effective May 1, 1972. 1154. Amendment 25-55, Effective April 26, 1982. 1155. Amendment 25-59, Effective November 26, 1984. 1156-1200. [RESERVED]

SECTIONS 25.853, 25.855, AND 25.1359

VIII

Appendix 1. CROSS REFERENCE FOR PART 25 ANO CAM 4b

Appendix 2. SYMBOLIC REGULATORY MESSAGES

Appendix 3. CRASHWORTHINESS ADVISORY CIRCULARS

Appendix 4. TEST PROCEDURES FOR EVALUATING NONSTANDARD

EXITS FOR TRANSPORT CATEGORY AIRPLANES

1481 1482

1501

1551 1551' 1551

1601 1601 1603 1605 1605 1610

EXITS FOR TRANSPORT CATEGORY AIRPLANES

1

1

1

1

1-40. [RESERVED]

Par 1 1 (thru 50)

SECTION 25.772 PILOT COMPARTMENT DOORS

41. Section 25.772 Did Not Exist Prior to Amendment 25-33.

42. AMENDMENT 25-33, Effective October 21, 1972.

a. Regulation.

(a) Except as provided in paragraph (b) of this section, if a lockable door is installed between the pilot compartment and the passenger compartment to comply with§ 121.313(f) of this chapter, the emergency exit configuration of the airplane must be designed so that neither crewmembers nor passengers need use that door in order to reach the emergency exits provided for them.

SECTION 25.772 PILOT COMPARTMENT DOORS

(b) The provisions of paragraph (a) of this section do not apply to an airplane that--

(1) Has a maximum passenger seating configuration of 20 seats or less; or

(2) Is excepted from the equipment requirements of § 121.313(f) under the provisions of§ 121.583(a) of this chapter.

b. Guidance. There is no guidance for this regulation.

43. AMENDMENT 25-47, Effective December 24, 1979.

a. Change to Regulation.

(a) Except as provided in paragraph (b) of this section, if a lockable door is installed between the pilot compartment and the passenger compartment to comply with§ 121.313(f) of this chapter, the emergency exit configuration of the airplane must be designed so that neither crewmembers nor passengers need use that door in order to reach the emergency exits provided for them. However, for passenger configuration, means must be provided to enable flight crewmembers to directly enter the passenger compartment from th~ pilot compartment if the cockpit door becomes jammed.

b. Guidance.

(1) Paragraph (a). Compliance may be shown by either analysis or demonstration.

Par 41 51

(2) Paragraph (a}. Acceptance of Frangible Doors. The following test procedure is acceptable to demonstrate that the door between the pilot compartment and the passenger compartment will not block the flight cre.wmembers' escap·e in the event the door is jammed. An acceptable means of showing compliance is by demonstrating that the door is frangible and the flightcrew participants can rapidly egress from the pilot compartment without assistance.

(i) The test should be conducted in an airplane, or a mockup if the mockup conforms to the production airplane's interior configuration. If a mockup is used, it should include the observer's seat(s), if they are part of the type design, and the bulkhead and door to be tested. The door should be blocked to simulate possible jamming from the top, bottom, and sides (closing and locking alone may not be adequate to simulate all possible jamming). If the fragments from the broken door could' cause an obstruction to the escape routes for passenger emergency egress, and if an emergency evacuation demonstration is required by airworthiness regulations or operating rules, consideration should be given to include the passengers in the test. For emergency evacuation demonstrations with passengers, refer to§ 25.803{c), Amendment 25-15.

(ii) Two participants representing a pilot in the left crew seat and a copilot in the right crew seat should be used for the test. They should be persons with no special escape abilities. The crewmembers should be a female approximately 60 inches tall and weighing 102 pounds and a male approximately 74 inches tall and weighing 210 pounds. The foregoing statures and weights represent the 5 and 95 percentiles respectively. The female participant will be instructed to break the door and be the first person to egress without assistance from the male participant. Instructions for enhancing the egress should be limited to those instructions that will be provided in the FAA-approved Airplane Flight Manual (AFM) or on the related placards.

(iii) The test should be conducted in night conditions. If conducted in a hangar during the day, the hangar should be draped and taped so that all sunlight is prevented from entering the hangar. Similar conditions should exist if conducted at night either in or out of a hangar. Lighting may be allowed at ground level to aid in leaving the area near the airplane providing the lighting is kept low and shielded so it does not aid evacuating the airplane. Use of emergency lighting is acceptable.

(iv) Personnel participating should be informed of the purpose of the demonstration and of the safety precautions. Safety of participants is the responsibility of the applicant, and should be considered to prevent

injuries to the participants without compromising the test results. Participants may wear protective gear such as crash helmets, but the protective gear, tools, or any other device should not be used to break throµgh the door. ·

44-60. [RESERVED]

44-60. [RESERVED]

. 52 ( thru 100) Par 43

SECTION 25.783 DOORS

61. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) Each cabin must have at least one easily accessible external door.

(b) There must be a means to loc~ and safeguard each external door against opening in flight (either

SECTION 25.783 DOORS

inadvertently by persons or as a result of mechanical failure). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the airplane.

Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even in darkness. Auxiliary locking devices may be used.

(c) Each external door must be reasonably free from jamming as a result of fuselage deformation in a minor crash.

(d) Each external door must be located where persons using them will not be endangered by the propellers when appropriate operating procedures are used.

(e) There must be a provision for direct visual inspection of the locking mechanism by crewmembers to determine whether external doors, for which the initial

opening movement is outward (including passenger, crew, service, and cargo doors), are fully locked. In addition, there must be a visual means to signal to appropriate crewmembers when normally used external doors are closed and fully locked.

(f) Cargo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e) of this section and be safeguarded against opening in flight as a result of mechanical f~ilure.

b. Guidance.

(1) Paragraphs (b} through {e). The requirements of these paragraphs apply to all cabin and pilot compartment external doors usable for entrance or egress. It is not restricted to the main cabin door. Cargo and service doors not suitable for emergency egress need only comply with

Par 61 101

§ 25.783(e) and be safeguarded against opening in flight as a result of mechanical failure.

(2) Paragraph (b). Auxiliary locking devices.

(i) The use of auxiliary locking devices is permitted. Such devices would include dual locking handles, other types of locking and safety devices, two position handles, and dual operation handles (where one operation

such as pushing or pulling on the handle unlocks the latching mechanism and the second operation of turning the handle unlatches the door for opening). Auxiliary locking devices should be used only as an additional safety factor

and should not be used as a means of correcting an inadequate design of the primary locking or latching means. The advantages to be gained from the installation of auxiliary or dual locking devices (safety chains and dual handle main locking means) should be weighed against the need to easily and rapidly open the door in case of emergencies so that the overall level of safety is as high as practicable.

(ii) All locking or safety means, including safety chains and latches of any kind, should be so positioned and designed that their presence, location and means of operation are obvious to one not familiar with door designs.

(A) The means of fastening safety devices should be sufficiently simple to make removal easy.

(B) Any emergency release mechanism installed to release the safety device should operate ~ith a simple motion and upon the application of relatively small forces.

(C) All locking devices should be readily operable from both inside and outside of the airplane and be appropriately marked both

inside and outside.

(iii) Auxiliary safety devices meeting the standards of paragraph (ii) above may be fastened in place during the entire flight. It will not be necessary to have such devices unlatched during takeoff and

landing. Auxiliary safety devices such as safety chains or bars that do not meet the standards of paragraph (ii) above may be used provided operating

instructions are installed at or near the device·and a placard is installed requiring the removal of such devices prior to takeoff and landing. For related guidance, see paragraph 35Ib(2).

(3) Paragraph (b). Power operated external doors. Power operated doors should be so designed that the door can be opened by manual means even when power is inactivated. The loss of power should not cause the door to become unlatched. Since emergency landings, such as the wheels-up condition, may result in the severance of electrical wires or rupture of hydraulic and pneumatic lines, the power which may be needed for operation of the doors or exits m~y be lost. Similarly, it is conceivable that under emergency. conditions, the electrical power source may be purposely interrupted to reduce the possibility of fire.

102 Par 61

(4) Paragraphs (b) and (e). Means for safeguarding against inadvertent opening in flight. Auxiliary locking devices may be used to reduce the probability of inadvertent opening in flight provi.ded they meet the standards and conditions covered above.

(i) It is acceptable to create a limited access zone in front of the door to eliminate the possibility of a passenger using the door handle as a steadying ~eans·and thereby inadvertently opening the door. Although · providing a restricted zone by means of a barrier may appear to conflict with the requirements of§ 25.813 for an unobstructed passageway to Type I and II emergency exits, it is considered that it would contribute sufficiently to the overall safety of the airplane occupants to be permitted. This device may be a rope, chain, rigid bar or gate. Such installations should be waist high to provide the maximum benefits for an adult and the end fastenings should be simple to make removal easy. It is not considered acceptable to install fulllength auxiliary doors, but waist-high rigid gates would be acceptable provided they open toward the door and will not block the opening of the cabin door in any way. The locking means should be one which could be easily overridden such as a spring-loaded ball type latch.

(ii) Flexible gates such as those made from webbing are not acceptable on the basis that persons may become entangled during an emergency egress. The use of a barrier to prevent persons from inadvertently opening the door in flight does not eliminate the need for a safety means to provide for possible malfunctioning of the primary locking mechanism; however, the auxiliary safetying means covered above may eliminate the need for a restricted zone.

(5) Paragraph (e). Direct visual inspection. The means of complying with paragraph (e} of this section will depend upon the type of door and locking mechanism used. In all cases there should be provisions to ascertain that an unsatisfactory condition does not exist after closing the door. In some instances a central window for viewing the position of the mechanism may be sufficient while other cases may require one or more windows

in the door frame to permit inspection of the bayonet location relative to that portion of the lock in the door frame. The need for or the number and location of inspection openings or windows will depend on the type of door and locking mechanism used. ·

(6) Paragraph (e). Visual indicating system. The objective herein is to be able to ascertain by visual means that the door or locking means is sufficiently engaged to eliminate hazards emanating from an improperly closed door. Outward opening doors present a different problem from inward opening doors. ·

(i) The visual indicating system may consist of an indicator for each individual door, or a system connecting all doors in series. If the latter system is used, it need not necessarily show which door is not fully locked.

(ii} It is not necessary that more than one crewmember be able to ascertain by a visual signal that all external doors, normally used by the

Par 61 103

AC 25-17

crew in supplying the airplane, or in loading and unloading passengers and cargo, are fully closed and locked. The visual signal should be located so that it may easily be seen by the appropriate crewmember from his station.

62. AMENDMENT 25-15, Effective October 24, 1967.

a. Change to Regulation.

(g) Each passenger entry door in the side of the fuselage must qualify as a Type A, Type I, or Type II passenger · emergency exit and must meet the requirement~ of§§ 25.807 through §·25.813 that apply to that type of passenger emergency exit. If an integral stair is installed at such a passenger entry door, the stair must be designed so that when subjected to the inertia forces specified in§ 25.561,

and following the collapse of one or more legs of the landing gear, it will not interfere ·to an extent that will reduce the effectiveness of emergency egress through the passenger entry door.

b. Guidance. There is no additional guidance for this amendment.

63. AMENDMENT 25-23, Effective May 8, 1970.

a. Change to Regulation.

(b) There must be a means to lock and safeguard each external door against opening in flight (either

inadvertently by persons or as a result of mechanical failure or failure of a single structural element). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the

airplane .. Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even

in darkness. Auxiliary locking devices may be used.

(f} Cargo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e} of this section and be safeguarded against opening

in flight as a result of mechanical failure or failure of a single structural element.

b. Guidance. There is no additional guidance for this amendment.

64. AMENDMENT 25-54, Effective October 14, 1980.

a. Change to Regulation.

(b) There must be a means to lock and safeguard each external door against opening in flight {either

inadvertently by persons or as a result of mechanical failure or failure of a single structural element either during or after closure). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the airplane.

Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even in darkness. Auxiliary locking devices may be used.

{e) There must be a provision for direct visual inspection of the locking mechanism to determine if external doors, for which the initial opening movement is not inward (including passenger, crew,

service, and cargo doors), are fully closed and locked. The provision must be discernible under operational lighting conditions by appropriate crewmembers using a flashlight or equivalent

lighting source. In addition, there must be a visual warning means to signal the appropriate flight crewmembers if any external door is not fully closed and locked. The means must be designed sach that any failure or combination of failures that would result in an erroneous closed and· locked

indication is improbable for doors for which the initial opening movement is not inward.

(f) External doors must have provisions to prevent the initiation of pressurization of the airplane to an unsafe level if the door is not fully closed and locked. In addition, it must be·shown by safety analysis that inadvertent opening is extremely

improbable.

(g) targo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e) of this section and be safeguarded against opening

in flight as a result of mechanical failure or failure of a single structural element.

(h) Each passenger entry door in the side of the fuselage must qualify as a Type A, Type I, or Type

AC 25-17

II passenger emergency exit and must meet the requirements of § 25.807 through§ 25.813 that apply to that type_ of passenger emergency exit.

(i) If an integral stair is installed in a passenger entry door that is qualified as a passenger emergency exit, the stair must be designed so that under the following conditions the effectiveness of passenger emergency egress will not be impaired:

(1) The door, integral stair, and operating mechanism have been subjected to the inertia forces

specified in§ 25.56I(b)(3), acting separately relative to the surrounding structure.

(2) The airplane is in the normal ground attitude and in each of the attitudes corresponding to . collapse of one or more legs of the landing gear.

(j) All lavatory doors must be designed to preclude anyone from becoming trapped inside the lavatory, and if a locking mechanism is installed, it be capable of being unlocked from the outside without the aid of special tools ..

b. Guidance. See AC 25.783-1, Fuselage Doors, Hatches, and Exits, for related guidance.

65-80. [RESERVED]

106 (thru 200) Par 64

SECTION 25.785 SEATS, BERTHS, SAFETY BELTS, AND HARNESSES

81. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

{a} Each seat, berth, safety belt, harness, and adjacent part of the airplane, at each station designated as occupiable during takeoff and landing, must be designed so that a person making proper use of these facilities will not suffer serious injury in an emergency landing as a result of the inertia forces specified in§§ 25.561.

SECTION 25.785 SEATS, BERTHS, SAFETY BELTS, AND HARNESSES

{b} Each seat and berth must be approved.

{c) Each occupant must be protected from head injury by--

{l) A safety belt and shoulder harness that will prevent the head from contacting any injurious object;

(2) A safety belt plus the elimination of any injurious object within striking radius of the head; or

(3) Safety belt plus a cushioned rest that will support the arms, shoulders, head and spine.

(d) If the seat backs do not have a firm hand hold, there must be a hand grip or rail along each aisle to enable occupants to steady themselves while using the aisles in moderately rough air.

{e) Each projecting object that would injure persons seated or moving about the airplane in normal flight must be padded.

{f) Each berth must be designed so that the forward part has a padded end board, canvas diaphragm, or equivalent means that can withstand the static load reaction of the occupant when subjected to the forward inertia force specified in§ 25.561. Berths must be free from corners and protuberances likely · to cause serious injury to a person ·occupy; ng the berth during emergency conditions.

{g) Each crewmember seat at flight deck stations must have provisions for a shoulder harness. These seats must meet strength requirements of paragraph {i) of this section.

AC 25-17

AC 25-17

(h) Cabin attendant seats must be in the passenger compartment near approved floor level emergency exits.

(i) Each seat, berth, and its supporting structure, must be designed for an occupant weight of 170 pounds, considering the maximum load factors, inertia forces, and reactions between the occupant,. seat, and safety belt or harness, at each relevant flight and ground load condition {including the emergency·Janding conditions prescribed in

§ 25.561). For berths, the forward inertia force must be considered in accordance with paragraph (f) of this section and need not be considered with respect to the safety belt.· In addition- -

(1) The structural analysis and testing of the seats, berths, and their supporting structures may be determined by--

(i) Assuming that the critical load in the forward, sideward, downward, and rearward directions (as determined from the prescribed flight, ground, and emergency landing conditions) acts separately; and

(ii) Using selected combinations of loads if the required strength in each specified direction is substantiated;

(2) Each pilot seat must be designed for the reactions resulting from the application of the pilot forces prescribed in§ 25.395; and

(3) The inertia forces specified in§ 25.561 must be multiplied by a factor of 1.33 (instead of the fitting factor prescribed in § 25.625) in determining the strength of the attachment of--

(i) Each seat to the structure; and

(ii) Each belt or harness to seat or structure.

b. Guidance.

(1) Paragraph (a). In order for the seat belt to be effective, it should be positioned to lay across the hip bone and ideally be about 45 degrees from the horizontal. An acceptable range for this angle is 35 degrees to 55 degrees. An acceptable range for the shoulder harness is 30 degrees above to 5 degrees below the horizontal. See AC 43.13-IA, Acceptable Methods, Techniques, and Practices -- Aircraft Inspection ~nd Repair.

(2) Paragraph (c). For side facing seat installations, the following are satisfactory and do not need a shoulder harness:

202 Par 81

(i) An unpadded bulkhead immediately adjacent to and forward of a normal width armrest.

(ii) Another occupant who serves as a "human cushion."

(3) Paragr.aph (c)(2). The striking radius of the head is considered to be an arc of 35 inches whose center is at the intersection of the plane of the uncompressed top of the seat cushion with the plane of the uncompressed front of the back cushion; commonly referred to- as the seat reference point

(SRP). The arc width is considered to extend to the centerlines of each armrest. Typical installations to be considered are bulkheads, cabinets, tables and passenger evacuation slide covers. If the sidewall configuration

is such that it is potentially hazardous in a combination of forward and side loads, it should be substantiated even if it might be slightly outside of the centerline of the armrest. Any surface less than 18 inches above the floor need not be considered. Surfaces within the 35-inch arc may be padded with energy absorbing material, such as one inch of either Ensolite (Type AH or HH), Klegecell or Airex 4070. Foam rubber is not satisfactory since it is an energy storing material. If the padding is easily removed, there should be acceptable placarding requiring the padding be in place during taxi, takeoff and lanqing. ·

{4) Paragraph (c){2). A flat surface, such as a table or partition, may be tested to the criteria of Society of Automotive Engineers (SAE) J921 or

the following criteria. If the surface meets either of these criteria, it is ~ot considered to be an injurious object and it need not be padded for taxi, takeoff and landing. Impact injury criteria is in AC 21-22, Injury Criteria for Human Exposure to Impact.

(i) A bowling ball may be used to simulate the head of a 170pound person whose seat belt is fastened and is subjected to 9 g. -

(ii) The ball shall impact the surface with at least 2780 inchpounds· of energy.

(iii) The rebound kinetic energy shall not exceed 375 inchpounds.

(iv) The average deceleration of the ball shall not exceed 225 g.

(v) The attachments of the test article shall not fail completely.

·{vi) No parts shall become loose or sharp·projections be formed that would be hazardous to the passengers.

(vii) The test article may deform locally.

{5) Paragraph (c)(2). Some passenger seats are designed with armrests that pivot upward such that the armrest could protrude beyond the

Par 81 203

seatbacks resulting in a potentially hazardous condi_tion to persons seated behind these seats: Armrests that are adequately delethalized or restricted such that they cannot protrude aft of either seatback in any position are acceptable.

(6) Paragraph (d). The seat back may serve as a firm hand hold. Since most seats are capable of breaking over, the breakover load must be adequate to be considered firm~ A load of 25 pounds minimum, acting horizontally, is considered adequate when applied at the top center of the seat back. {See paragraph 4llb{8) for maximum breakover force.)

{7) Paragraph (f). Each berth installation should include a seat belt located approximately at the occupant's stomach. For a berth installation with the feet facing forward, a bag, enclosing the legs to catch the upper torso when subjected to 9g, would be satisfactory in lieu of a padded end board. If the head is facing forward, a strap over each shoulder configuration would be satisfactory. If the berth is side ·facing, a padded side board or two belts, located approximately at the thighs and approximately at the chest, would be satisfactory.

(8) Paragraph (i). In order to reduce the deceleration

119 11 -forc~s on occupants, some forward facing seats are designed to collapse. Usually, the design incorporates collapsible front legs. Such is acceptable if the collapse does not occur until a minimum of 89 has been applied. After the collapse has occurred, the ultimate load of 9g should be applied and maintained for the required three seconds. The activation of the energy absorbing feature should not result in occupant injury. Various dimensions, such as 35 inches to injurious object clearance, aisle width and clearance, and interference with exits, should be evaluated before and after activation of the energy absorbing feature. Required dimensional clearances, such as aisles, passageways, flight attendant assist spaces, exit opening envelopes, and clearance between seats and potentially injurious surfaces must be maintained after the energy-absorbing feature is activated. The final position of the seat should not trap occupants.

{9) Paragraph (i). Technical Standard Order TSO-C22 is applicable only to seat belts. Technical Standard Order (TSO) Cl14 may be applicable to shoulder harnesses, or they may be approved as part of the airplane. Sled tests with anthropomorphic dummies have shown that shoulder harness loads for forward facing seats can vary between 40 percent and 60 percent of the total load. Therefore, it will be acceptable to substantiate a shoulder harness load of 60 percent (See AC 25.785-1, Flight Attendant Seat Requirements): 0.6x9gxl70 pounds= 918 pounds. If the seat belt is not approved under TS0- C22 or later revision, it should be approved as part of the airplane. The seat belt should be substantiated for 100 percent of the occupant load: 9g x 170 pounds= 1530 pounds. This is necessary even if the shoulder harness is permanently attached to the seat belt, since it is usually possible to utilize the seat belt without using the shoulder harness. The 1.33 fitting factor is applicable to these configurations.

(10) Paragraph (i){l}(i). A seat is normally approved to TSO-C39 or later revision. This approval may not account for the critical load when

204 Par 81

occupied by less than maximum occupants, e.g., one or two occupants in a trip 1 e seat. In some seat designs, occupancy by 1 es.s than the maximum could be a critical design load for a particular structural member. All possible combinations of seat place occupancy should be substantiated by test or analysis. The loads for underseat baggage restraint systems attached to the seat should be added to seat loads. See§ 25.787 guidance for underseat baggage criteria. This can be done by the TSO manufacturer when doing the TSO substantiation or by the applicant who is installing the seat.

{11) Paragraph {i)(3). The 1.33 factor is only required to be applied to the stated attachments. This factor should be applied to both ends of each attachment, i.e., the seat .end and the airplane end. If the applicant wishes to test the entire seat and belt assembly to this 1.33 factor, it is

satisfactory.

82. AMENDMENT 25-15, Effective October 24, 1967.

a. Change to Regulation.

(c) Each occupant of a sideward facing seat must be protected from head injury by a safety belt and an energy absorbing rest that will support the arms, shoulders, head, and spine, or by a safety belt and a shoulder harness that will prevent the head from contacting any injurious object. Each occupant of any other seat must be protected from head injury by--

{l) A safety belt and shoulder harness that will prevent the head from contacting any injurious object;

(2) A safety belt plus the elimination of any injurious object within striking radius of the head; or

(3) A safety belt and an energy absorbing rest that will support the arms, shoulder, head, and spine.

b. Guidance. Paragraph {c). For sideward facing seats, this change removed the option of a safety belt plus eliminated any injurious object from within striking radius of the head. This option is still satisfactory for . forward and aft facing seats. The "human cushion" or unpadded bulkhead concept is not an adequate energy absorbing rest and therefore does not comply with this version of the regulation. The shoulder harness may be a diagonal shoulder harness over the forward shoulder.

83. AMENDMENT 25-20, Effective April 23, 1969.

a. Change to Regulation.

{c) Each occupant of a seat that makes more than an IS-degree angle with the vertical plane containing the airplane centerline, must be protected from head

injury by a safety belt and an energy absorbing rest

that will support the arms, shoulders, head, and spine, or by a safety·belt and shoulder harness that will prevent the head from contacting any injurious object. Each occupant of any other seat must be protected from head injury by--

b. Guidance. Paragraph (c}. The IS-degree requirement applies to both forward and aft facing seat installations. If the forward direction is considered as O degrees or 360 degrees of a circle, the segments from 18 degrees to 162 degrees and 198 degrees to 342 degrees are considered a side facing seat and the seat installation must comply with one of the two options stated in the regulation.

84. AMENDMENT 25-32, Effective May 1, 1972.

a. Change to Regulation.

(c} Each occupant of a seat that makes more than an 18degree angle with the vertical plane containing the airplane centerline, must be protected from head injury by a safety belt and an energy absorbing rest that will support the arms, shoulders, head, and spine, or by a safety belt and shoulder harness that will prevent the head from contacting any injurious object. Each occupant of any other seat must be protected from head injury by a safety

belt and, as appropriate to the type, location, and angle of facing of each seat, by one or more of the following:

(1) A shoulder harness that will prevent the head from contacting any injurious object.

(2} The elimination of any injurious object within striking radius of the head.

(3) An energy absorbing rest that will support the arms, shoulders, head, and spine.

b. Guidance. There is no additional guidance for this amendment.

85. AMENDMENT 25-51, Effective March 6, 1980.

a. Change to Regulation.

{g} fach seat at a flight deck station must have a combined safety belt and shoulder harness with a single-point release that permits the flight deck occupant, when seated with safety belt and shoulder harness fastened, to perform all of the occupant's necessary flight deck functions. There must be a means to secure each combined safety belt and

shoulder harness, when not in use, to prevent

AC 25-17

interference with the operation of the airplane and with rapid egress in an emergency.

(h) Flight attendant seats in passenger compartments must be near required floor level emergency exits and be equipped with a restraint system consisting of a combined safety belt and shoulder harness unit with a single-point release. There must be means to secure each combined safety belt and shoulder harness, when not in use, to prevent interference with rapid egress in an emergency. In addition--

Cl) To the extent possible without compromising their proximity to require~ floor level emergency exits, flight attendant seats must be located to provide a direct view of the cabin area for which the flight attendant is individually responsible.

(2) Flight attendant seats must--

(i) Either be forward or rearward facing, with an energy absorbing rest that is designed to support ·the arms, shoulders, head and spine; and

(ii) Be positioned so that when not in use they will not interfere with the use of passageways and exits.

(i) each seat, berth, and its supporting structure must be designed for an occupant weight of 170

pounds~ considering the maximum load factors, inertia forces, and reactions between the occupant, seat, and safety belt, harness or both at each relevant flight and ground load condition (including the emergency landing conditions prescribed in § 25.561). For berths, the forward inertia force must be considered in accordance with paragraph (f) of this section and need not be considered with respect to the safety belt. In addition--

(j) Each flight attendant seat must be located to minimize the probability of its occupant suffering

injury by being struck by items dislodged in a galley, or from a stowage compartment or serving cart. All items expected in these locations in service must be considered •.

(k) Each forward observer's seat required by the operating rules must be shown to be suitable for use

in .conducting the enroute inspections prescribed by § 121.58l(a).

b. Guidance.

. (1) Paragraphs (g) and (h). The combined safety belt and shoulder harness should consist of a standard safety belt and a shoulder harness with a strap over each shoulder. The shoulder harness straps should be as close to the neck as possible and may join behind the neck or each strap may attach separately to structure. In the front, the shoulder harness straps should attach to the buckle or safety belt near the buc~le. Some harness geometries have been found acceptable where the shoulder harness straps are attached to the seat belt attach fittings. Ideally, the buckle should be located near the center of the torso. The single point release should be one action in which both the safety belt and shoulder harness are released simultaneously. The means provided to secure each combined safety belt and harness should be designed so that the belt and harness strap material does not get repeatedly creased over a long period of wear.

(2) Paragraphs (g), (h} and (j). See AC 25 .. 785-1, Flight Attendant Seat Requirements, for additional acceptable means of compliance.

86-100. [RESERVED]

86-100. [RESERVED]

208 (thru 300) Par 85

SECTION 25.787 STOWAGE COMPARTMENTS

101 .. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) Each cargo and baggage compartment must be designed for its placarded maximum weight and contents and for the critical load distributions at the appropriate maximum load factors corresponding to the specified flight and ground load conditions, except the emergency landing conditions of § 25.561.

SECTION 25.787 STOWAGE COMPARTMENTS

(b) There must be.a means to prevent the contents in the compartments from becoming ·a hazard by shifting, under the loads specified in paragraph (a) of this section.

(c) There must be a means to protect the occupants from injury by the contents of any compartment, under the emergency landing conditions of§ 25.561.

b. Guidance.

(1) Paragraph (a). Compartments placarded "No Stowage" need not have a weight limit placard. Compartments placarded "Emergency Equipment Only" need not have a weight limit placard provided the compartment is filled with designated emergency equipment that does not exceed the compartment's limit.

(See paragraphs 80lb(l}(ii), 104lb(5) and 110lb(2).)

(2) Paragraph (b). Baggage can be free if it can be shown that the forward barrier and cargo liner are able to restrain impact loads and the compartment is small enough to prevent significant shifts in center of gravity

(e.g.). A 9g barrier net or other structure are required in all cargo versions if the cargo is not restrained to§ 25.561 loads. In this case the cargo is restrained to flight and ground loads to prevent e.g. movement. If no 9g barrier net is used, the cargo is restrained to§ 25.561 loads in an approved installation such as containers or pallets. (See paragraph 104lb(9).)

102. AMENDMENT 25-32, Effective May I, 1972.

a. Change to Regulation.

(a) Each compartment for the stowage of cargo, baggage, carry-on articles, and equipment (such as life rafts), and any other stowage compartment must be designed for its placarded maximum weight of contents and for the critical load distribution at the appropriate maximum load factors corresponding

to the specified flight and ground load conditions, and to the emergency landing conditions of§ 25.56l{b), except that the forces specified in the emergency landing conditions need not be applied to compartments located below, or forward, of all occupants in the airplane. If the airplane has a passenger seating configuration, excluding pilots seats, of 10 seats or. more, each stowage compartment in the passenger cabin, except for

underseat and overhead compartments for passenger convenience, must be completely enclosed.

b. Guidance. Paragraph (c)·was deleted with the adoption of§ 25.789. (ll The intent for requiring completely enclosed stowage compartments is to providemore protection than that provided by restraint devices such as tie-down straps or webbing (with or without a curtain).

(2) · Standard design criteria for underseat baggage restraint. (These criteria can be used for test or analysis purposes.)

{i) Forward·restraint design criteria.

(A) Load factor - 9g forward.

(8). Basic baggage weight - 20 pounds per individual seat.

(C) Bag dimension - 3 X 12 X 17 inches (assumed rigid).

NOTE: These dimensions represent what is considered the most severe case and are not to be construed as the maximum baggage size which should be tonsidered. The restraint device should be capable of restraining baggage of a size which can be stowed,·under-the seat in the available space, but the weight need not be more than 20 poands.

(D} The bag surface upon which it rests should be assumed smooth so as to minimize ·any friction restraint.

(E) The load (20 X 9 = 180 pounds) should be assumed. applied through the bag with the seat mounted in its normal position. The 17 X 3-inch bag dimension should impinge on the restraint device unless the underseat dimensions are such that the test bag would protrude beyond the seat. In that case the 3 X 12-inch dimension should be used.

(F} The critical load conditions for the underseat baggage restraints should be identified and demonstrated.

(G) The bottom of th~ restraint system should be no more than 2 1/2 inches above the floor level of the airplane. The top of the system should be no less than 3 inches above the floor level of the airplane.

302 Par 102

{ii) Side restraining design criteria.

(A) The underseat baggage side restraint system should be capable of restraining a 20-pound rigid article per seat with the dimensions of 3 X 12 X 17 inches at 1.5g of side loading. {20 pounds X 1.5 g = 30 pounds per article.) ·

(B) The side restraint system should be capable of restraining the article at l.Sg sidewards with the 17-inch dimension oriented fore and aft in the airplane.

(C) If the restraint system allows application of a footload, the system should be capable of withstanding a 300-pound standing load, applied in the most critical mode, without degrading either the basic forward load carrying capability or the side load carrying capabilities noted above or resulting in deformation causing the system to pose a tripping hazard.

{D) The system should be capable of withstanding the most critical loading condition due to asymmetrical loading of the system.

(E) The bottom of the restraint system should be no more than 2 1/2 inches above the floor level of the airplane~ The top of the system should be no less than 3 inches above the floor level of the airplane. The restraint system should extend a minimum of 8.75 inches aft from the aft face of the forward restraint portion of the system.

(F} The side restraint system should not present a tripping hazard either for ingress to the seat or egress to the aisle or to the evacuation route.

(G) The restraint system should not protrude into the aisle or evacuation route farther than the seat armrest on the aisle side.

{3) If overhead stowage compartments are intended for carriage of baggage, other than articles of loose clothing, they must be provided with approved restraining devices or doors(§ 121.589 (b}).

103 .. AMENDMENT 25-38, Effective February I, 1977.

a. Change to Regulation.

(c) If cargo compartment lamps are installed, each lamp must be installed so as to prevent contact between lamp bulb and cargo.

b. Guidance. There is no additional guidance for this amendment.

Par 102 303

AC 25-17

104. AMENDMENT 25-51, .Effective March 6, 1980.

a. Change to Regulation.

(b) There must be a means to prevent the contents in the compartments _from becoming a hazard by shifting, under the loads specified in paragraph (a) of this section. For stowage compartments in the passenger and crew cabin, if the means used is a latched door, the design must take into consideration the wear and deterioration expected in service.

b. Guidance. The intent of the last sentence of paragraph (b) is to prevent inadvertent opening of the latched doors of stowage compartments by specifically requiring that service wear and deterioration be considered in the design. This is not the same as the§ 25.789 requirement which is directed to retention of items of mass subjected to maximum load factors. The installation of acceptable dual latching devices, each of which can withstand the applicable loads, has been found to be one means to show compliance with this rule.

105-120. [RESERVED]

105-120. [RESERVED]

304 (thru 320) Par 104

SECTION 25.789 RETENTION OF ITEMS OF MASS

121. Section 25.789 Did Not Exist Prior to Amendment 25-32.

122. AMENDMENT 25-32, Effective May 1, 1972.

a. Regulation.

Means must be provided to prevent each item of mass

(that is part of the airplane type design) in a passenger or crew compartment from becoming a hazard by shifting under the appropriate maximum load factors corresponding to the specified flight and ground load conditions, and to the emergency landing conditions of§ 25.56l(b).

SECTION 25.789 RETENTION OF ITEMS OF MASS

b. Guidance. There is no guidance for this amendment.

123. AMENDMENT 25-46, Effective December 1, 1978.

a. Regulation.

(a) Means must be provided to prevent each item of mass (that is part of the airplane type design) in a

passenger or crew compartment or galley from becoming a hazard by shifting under the appropriate maximum load factors corresponding to the specified flight and ground load conditions, and to the emergency landing conditions of§ 25.56l(b) .

. (b) Each interphone restraint system must be designed so that when subjected to the load factors specified in§ 25.56I(b)(3), the interior phone will remain in its stowed position ..

b. Guidance. There is no guidance for this amendment.

124-140. [RESERVED]

124-140. [RESERVED]

AC 25-17

Par 121 321 (thru 360)

SECTION 25.791 PASSENGER INFORMATION SIGNS

141. Section 25.791 Did Not Exist Prior to Amendment 25-32.

142. AMENDMENT 25-32, Effective May 1, 1972.

a. Regulation.

When passenger information signs are installed to comply with the operating rules of this chapter, at least one sign (using either letters or symbols) notifying when smoking is prohibited and one sign (using either letters or symbols) notifying when safety belts should be fastened must, when illuminated, be legible to each person seated in the passenger cabin under all probable conditions of cabin illumination. Signs which notify when safety

SECTION 25.791 PASSENGER INFORMATION SIGNS

belts should be fastened and when smoking is prohibited must be so constructed that the crew can turn them on and off.

b. Guidance.

(1) Each cabin occupant, including cabin attendants but not pilot compartment occupants, should be able to see a passenger information sign when seated in a seat occupiable for taxi, takeoff, and landing. This should be accomplished for any seat position such as, upright, reclined, swiveled or tracked. The sign should be readable by a person with 20/20 vision. To see the sign, the head may be moved about to normal positions.

(2) The words ."FASTEN SEAT BELT" and "NO SMOKING" are acceptable. In remote areas, such as the lavatory or lower lobe galley, a sign with the words "RETURN TO SEAT" is acceptable. This s1gn should be operated by the same switch as the "FASTEN SEAT BELT" sign.

(3) See Appendix 2 for acceptable symbols for these signs.

143-160. [RESERVED]

143-160. [RESERVED]

Par 141 361 { thru · 380)

SECTION 25.793 FLOOR SURFACES

161. Section 25.793 Did Not Exist Prior to Amendment 25-SL

162. AMENDMENT 25-51, Effective March 6, 1980.

a. Regulation.

The floor surface of all areas which are likely to

become wet in service must have slip resistant properties.

SECTION 25.793 FLOOR SURFACES

AC 25-17

b. Guidance. Military Specification Mil-W-50448, entitled "Walkway Compound, Nonslip and Walkway Matting, Nonslip", provides an acceptable standard for the slip resistant properties required by this paragraph as well as that of§ 25.803.

163-250. [RESERVED]

Par 161 381 (thru 400)

SECTION 25.801 DITCHING

SECTION 25.801 DITCHING

251. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) If certification with ditching prov1s1ons is requested, the airplane must meet the requirements of this section and§§ 25.807(d), 25.1411, and 25.1415(a).

(b) Each practicable design measure, compatible with the general characteristics of the airplane, must be taken to minimize the probability that in an emergency landing on water, the behavior of the airplane would cause immediate injury to the occupants or would make it impossible for them to escape.

(c) The probable behavior of the airplane in a water landing must be investigated by model tests or

by comparison with airplanes of similar configuration for which the ditching characteristics are known. Scoops, flaps, projections, and any other factor likely to affect the hydrodynamic characteristics of the airplane, must be considered.

(d) It must be shown that, under reasonably probable water conditions, the flotation time and trim of the airplane will allow the occupants to leave the airplane and enter the liferafts required by§ 25.1415. If compliance with this provision is shown by buoyancy and trim computations, appropriate allowances must be made for probable structural damage and leakage. If the airplane has fuel tanks (with fuel jettisoning provisions) that can reasonably be expected to withstand a ditching without leakage, the jettisonable volume of fuel may

be considered as buoyancy volume.

(e) Unless the effects of the collapse of external doors and windows are accounted for in the

investigation of the probable behavior of the airplane in a water landing (as prescribed in paragraphs (c) and (d) of this section), the external doors and windows must be designed to withstand the probable maximum local pressures.

AC 25-17

b. Guidance.

(l} Background Information. The expression "reasonably probable water conditions" is considered judgmental in application to compliance for ditching and has never been specifically defined as to sea state force or wave height. Early ditching investigations of dynamic models were conducted by the National Advisory Committee for Aeronautics (NACA) at Langley Field, Virginia, and NACA Report 1347, issued in 1958 and reflecting a compilation of such test results, set the precedence for early and modern transport airplane designers

in substantiating airplanes for ditching by analyses. Such early tests were based on calm-water landings with the supposition that rough-water landings of particular models that were made ~arallel to waves or swells would exhibit the same general type of performance. Later rough-water ditching investigations of models were conducted and their results were compiled in documents such as Technical Note No. D-101, issued by the National Aeronautics and Space Administration (NASA) in 1959, and also referred to by designers in respective ditching analyses. In addition to reference to actual ditching incidents, it became an acceptable practice for designers to substantiate the ditching behavior of a proposed airplane design by comparisons in basic geometric configuration to airplane designs approved for ditching by the models tested at Langley Field. Parametric comparisons usually revealed some identicalness in geometric aspects and where obvious discrepancies in dimensional relationships were evident, predetermined correction factors were applied.

(2) Paragraph (b). Ditching load factors may be determined by model tests. Landing procedures or design measures must be established that limit the factors to those listed in§ 25.561. Load factors above these are considered to expose occupants to injurious loads. In addition, standard. parts such as seats, belts, and harnesses are designed to§ 25;551 load factors. Higher load factors in the downward direction may be acceptable provided the structural cqmponents are designed for the higher loads and also provided it can be shown that the occupants are protected from serious injury under these loads.

(3) Paragraph (d}. A maximum permissible evacuation time for liferafts per the rule is also considered judgmental in scope for ditching compliance. During certification, it is usually shown by analysis that an airplane will float for a period of time exceeding the most conservative estimate of. time required to completely evacuate the airplane. Evacuation times and rates for liferaft type devices are normally established by analysis and included in the particular airplane model ditching and flotation document presented for approval during type certification.

(4) Paragraph (d). Prior to approval of any size or type of transport airplane for ditching ~pproval under§ 25.801, there must be evidence of an engineering evaluation of the provisions for installing the emergency equipment specified in§ 25.1411.

(5) Paragraph (d). In approving an airplane for overwater flight certification, two ditching conditions are examined. The first condition is the "planned ditching" case in which there is sufficient time to prepare the

402 Par 251

airplane for ditching and adjustments have been made to airplane weight and e.g. to account for loss of such items as engines, nacelles, and trailing edge flaps on impact with the water. The other condition is the "unplanned ditching" (§ 25.807(d)) case in which the airplane enters the water with

insufficient time to prepare for ditching. The most critical situation ·for this case is at maximum gross weight due to a failed or aborted takeoff. No airplane damage is considered for the "unplanned ditching" case.

(6) Paragraph (d).· As to ditching structµral criteria, external pressures must be determined for the fuselage and all external doors and exits that are subject to hydrodynamic forces. This can be determined by measurements on ditching models or by analysis based on tests. Section 25.533

"Hull and Main Float Bottom Pressure Loads" may be a source of some pressure information if similarity can be shown. The use of pressure distribution data from similar model airplanes is acceptable-and is preferred over purely_ analytical methods.

252-270. [RESERVED]

252-270. [RESERVED]

Par 251 403 (thru 450)

SECTION 25.803 EMERGENCY EVACUATION

271. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) Each crew and passenger area must have emergency means toallow rapid evacuation in crash landings, with the landing gear extended and retracted, considering the possibility of the airplane being on fire.

SECTION 25.803 EMERGENCY EVACUATION

(b) The passenger and crew access doors and service doors may be considered as emergency exits if they meet the applicable requirements of this section and§§ 25.805 and 25.813.

(c) If the airplane is divided into separate compartments without the minimum unobstructed passageway between compartments required by§ 25.813, this section and §§ 25.805 through 25.815 apply to each compartment independently.

b. Guidance. There is no guidance for this regulation.

272. AMENDMENT 25-1, Effective June 7,§ 1965.

a. Change to Regulation.

Paragraph {c} was deleted from this regulation.

b. Guidance. There is no additional guidance for this amendment.

273. AMENDMENT 25-15, Effective October 24, 1967.

a. Change to Regulation.

(a) Each crew and passenger area must have emergency means to allow rapid evacuation in crash landings, with the landing gear extended and retracted, considering the possibility of the airplane being on fire.

(b) Passenger ventral and tail cone, crew access, and service doors may be considered as emergency exits if they meet the applicable requirements of this section and§§ 25.805 through 25.813.

(c) Except as provided in paragraph {d) of this section, on airplanes having a seating capacity of more than 44 passengers, it must be shown by actual demonstration that the maximum seating capacity, including the number of crewmembers required by the operating rules for which certification is requested can be evacuated from the airplane within 90 seconds. Evacuees using stands or ramps allowed by subparagraph (8) of this paragraph are

AC 25-17

considered to be on the ground when they are on the stand or ramp, provided that the acceptance rate of the stand or ramp is no greater than the acceptance rate of the means available on the airplane for descent from the wing during an actual crash situation. The demonstration must be conducted under the following conditions:

(1) It must be conducted either during the dark of the night or during daylight with the dark of the night simulated, utilizing only the emergency lighting system and utilizing only the emergency exits and emergency evacuation equipment on one side of the fuselage, with the airplane in the normal ground attitude, with landing gear extended.

(2) All emergency equipment must be installed in accordance with specified limitations of the equipment. ·

(3) Each external door and exit, and each internal door and curtain must be in a configuration to simulate a normal takeoff.

(4) Seat belts and shoulder harnesses {as required) must be fastened.

(5) A representative passenger load of persons in normal health must be used as follows:

(i) At least 30 percent must be female. . . (ii) Approximately five percent must be over 60 years of age, with a proportionate number of

females.

(iii) At least five percent but no more than 10 percent must be children under 12 years of age, prorated through that age group.

(6) Persons who have knowledge of the operation of the exits and emergency equipment may be used to represent an air carrier crew. Such representative crewmembers must be in their seats assigned for takeoff and landing and none may be seated next to an emergency exit unless that seat is his assigned seat for takeoff. They must remain in their assigned seats until receiving the signal for the beginning of the demonstration.

(7) There can be no practice or rehearsal of the demonstration for the passengers except that they may be briefed as to the location of all emergency exits before the demonstration.

(8) Stands or ramps may be used for descent from the wing to the ground.

(9) All evacuees other than those using an overwing exit must leave the airplane by the means provided as part of the airplane's equipment.

(d) The emergency evacuation demonstration need not be repeated after a change in the interior arrangement of the airplane or an

increase of not more than five percent in passenger seating capacity over that previously approved by actual demonstration, or both, if it can be substantiated by analysis, taking due account of the differences, that all the passengers for which the airplane is certificated can evacuate within 90 seconds.

(e) An escape route must be established from each overwing emergency exit, marked and (except for flap surfaces suitable as slides) covered with a slip resistant surface~)

b.. Guidance.

(1) Paragraph (c).

(i)

11The maximum capacity for which certification is requested" refers to the airplane model presented for certification. Subsequent models which have planned passenger capacities in excess of the certificated model

should be substantiated on an individual basis.

(ii) All passengers and crewmembers used in the demonstration must be evacuated to the ground or off-wing stand or ramp, if used, within 90

seconds to constitute a successful 90 seconds test. Use only the number of passengers for which approved seating is provided, not to exceed the limits of § 25.807(c) or (d). No credit is given for the number of evacuees on the ground at 90 seconds if all persons have not been evacuated.

(iii) Federal Aviation Administration observers should be stationed inside the airplane at expected critical locations, and outside the airplane at each exit to be used.

(iv) The·"acceptance rate" of the stand or ramp refers to the width of the passage to the stand or ramp.

(v) The airplane should-be configured wfth minimum aisle and passage clearance expected to be type certificated. This may require combining features of more than one model.

(2) Paragraph (c)(l). One exit from each pair of exits should be used. Illumination on the floor or ground may be used, but it. should be kept low and shielded against shining into the airplane windows or doors.

(3) Paragraph (c)(2).

(i) The emergency descent devices used in the demonstration should be those to be in the airplane type design. The slide certification

Par 273 453

program should have progressed to the point where the system is reliable and can be expected to perform safely during the demonstration.

(ii) The airplane interior need not be a specific airline configuration. For example, galleys and other furnishings may be simulated by mockups, seats need not be TSO'd, etc. The interior should be described in

sufficient detail to allow an FAA conformity inspection and an FAA interior. compliance inspection.

(4) Paragraph (c)(5). The following two age-sex distrib4tions (A and B) are acceptable alternates to that stipulated in this paragraph:

Percent Percent Age of Total of Female

A. 21-50 80 30

51-59 15 40

60+ 5 30 - - - - - - - - - - - - - - - - - - - - - . . - - - - - - B. 18-50 75 30

51-60 25 40

(5) Paragraph (c)(6).

(i) Neither the crew nor passengers should hear or otherwise receive any indication that the demonstration is about to begin. The first indication to persons on board the airplane should be the test start signal.

(ii) Following the test start signal, the flightcrew should simulate the time required for normal pilot compartment procedures prior to evacuating the flight deck.

(iii) A group of crewmembers in exce·ss of the number required for the demonstration should be available. The FAA will select the crew that will participate in the test from this group. Subsequent tests, if required, may use crewmembers from the group remaining.

(6) Paragraph (c)(S). If the airplane is equipped .with an off-wing assist means, it should be used during the demonstration in lieu of any stands or ramps.

(7) Paragraph (c)(9).

(i) If safety pillows or other equipment unique to the active exits are employed, passengers and crew should enter the airplane through a tunnel or other means that prevents them from viewing the airplane exterior.

454 Par 273

(ii) Video cameras used to record activity inside the airplane should be positioned so as not to reveal the exits used in this demonstration. This may require the installation of cameras at inoperative exits.

(iii) If exit deactivation is by an external indication {e.g. red light outside exit), this indication should not be visible from inside the airplane until after the demonstration has begun. Alternatively, unlit bulbs may be visible at all exits.

{iv) Airplanes equipped with emergency descent means should be so equipped at inactive exits as well as active exits.

(v) Safety personnel stationed outside the airplane to prevent injury to the participants, should not aid participants (until they have cleared the descent means) or interfere with the evacuation process, or

position the assist means following its deployment.

(8) Paragraph {e}.

(i) Military Specification Mil-W-5044B, entitled "Walkway Compound, Nonslip and Walkway Matting, Nonslip", provides an acceptable standard for the slip resistant surface required by this paragraph as well as that of§ 25.793.

(ii) A 42-inch wide escape path is acceptable for airplanes incorporating dual overwing Type III exits.

274. AMENDMENT 25-17, Effective June 20, 1968.

a. Change to Regulation.

(c) Except as provided in paragraph (d) of this section, on airplanes having a seating capacity of more than 44 passengers, it must be shown by actual demonstration that the maximum seating capacity, including the number or crewmembers required by the operating rules, for which certification is requested can be evacuated from the airplane to the ground within 90 seconds. Evacuees using stands or ramps allowed by subparagraph (8) of this paragraph are considered to be on the ground when they are on the stand or ramp, provided that the passage width of the stand or ramp is no greater than the acceptance rate of the means available on the airplane for descent from the wing during an actual crash situation. The demonstration must be conducted under the following conditions:

b. Guidance. There is no additional guidance for this amendment.

Par 273 455

275. AMENDMENT 25-20, Effective April 23, 1969.

a. Change to Regulation.

(b) Passenger ventral and tail cone exits and any floor level door or exit in the side of the fuselage (other than those

leading into a cargo or baggage compartment that is not accessible from the passenger cabin) that is 44 or more inches high and 20 or more inches wide, but not wider than 46 inches, must meet the applicable emergency exit requirements of this

section and§§ 25.807 through 25.813.

(c)(l) It must be conducted either during the dark of the night or during daylight with the dark of the night simulated, utilizing only the emergency lighting system and utilizing only the minimum number of required emergency exits and the emergency evacuation equipment on one side of the fuselage with the

airplane in the normal ground attitude with landing gear extended.

b. Guidance. There is no additi~nal guidance for this amendment.

276. AMENDMENT 25-32, Effective May 1, 1972.

a. Change to Regulation.

(e) An escape route must be established from each overwing emergency exit, and (except for flap surfaces suitable as slides) covered with a slip resistant surface. Except where a means for channeling the flow of evacuees is provided--

. (1) The escape route must be at least 42 inches wide at Type A passenger emergency exits and must be at least two feet wide at all other passenger emergency exits, and ·

(2) The escape route surface must have a· reflectance of at least 80 percent, and must be defined by markings with a surface-tomarking contrast ratio of at l~ast 5:1.

b. Guidance. There is no additional guidance for this amendment.

277. AMENDMENT 25-46, Effective December 1, 1978.

a. Change to Regulation.

This amendment substantially revised the regulation to

incorporate Part 121 requirements ..

(c) Except as provided in paragraph (d) of this section, for airplanes having a seating capacity of more than 44 passengers, it must be shown by actual demonstration that the maximum seating

Par 277 .

AC 25-17

capacity, including the number of crewmembers required by the operating rules for which certification is requested, can be evacuated from the airplane to the ground within 90 seconds. The demonstration must be conducted under the following conditions:

(1) It must be conducted either during the dark of the night or during daylight with the dark of the night simulated. If the demonstration is conducted indoors during daylight hours, it must

be conducted with each window covered and each door closed to minimize the daylight effect. Illumination on the floor or ground may be used, but it must be kept low and shielded against

shining into the airplane's windows or doors.

{2) The airplane must be in a normal attitude with landing gear extended.

(3) Stands or ramps may be used for descent from the wing to the ground, and safety equipment such as mats or inverted life rafts may be placed on the floor or ·ground to protect participants. No other equipment.that is not part of the airplane's emergency evacuation equipment may be used to aid the participants in reaching the ground.

{4) Except as provided in paragraph (c)(l) of this section, only the airplane's emergency lighting system may provide

ill umi nation.

{5) All emergency equipment required for the planned operation of the airplane must be installed.

(6) Each external door and exit, and each internal door or curtain, must be in the takeoff configuration.

(7) Each crewmember must be seated in the normally assigned seat for takeoff and must remain in that seat until receiving the signal for commencement of the demonstration. Each crewmember must be--

{i) For compliance wtth this section or§ 121.291 of this chapter, a member of a regularly scheduled line crew, or

(ii) For compliance -with this section, a person having knowledge of the operation of exits and. emergency equipment.

(8) A representative passenger load of persons in normal health must be used as follows: ·

(i) At least 30 percent must be females.

(ii) At least five percent must be over 60 years of age with a. proportionate number of females.

AC 25-17

(iii) At least five percent but not more than 10 percent, must be children under 12 years of age~ prorated through that age group.

(iv) Three life-size dolls, not included as part of the total passenger ·load, must be carried by passengers to simulate live

infants two years old or younger.

(v) Cr~wmembers, mechanics, and training personnel who maintain or operate the airplane in the normal course of their duties, may not be used as passengers.

(9) No passenger may be assigned a specific seat except as the Administrator may require. Except as required by paragraph {c)(I2) section, no employee of the applicant may be seated next to an emergency exit.

(10) Seat belts and shoulder harness (as required) must be fastened.

(11) Before the start of the demonstration, approximately onehalf of the total average amount of carry-on baggage, blankets, pillows, and other similar articles must be distributed at several locations in the aisles and emergency exits access ways to create minor obstructions.

(12) Each crewmember must be seated in his normally assigned seat for takeoff and must remain in that seat until receiving the signal. for commencement of the demonstration. ·

(13) No prior indication may be given to any crewmember or passenger of the particular exits to be used in the demonstration.

(14) The applicant may not practice, rehearse, or describe the demonstration for the participants nor may any participant have taken part in this type of demonstration within the preceding six months.

{15) The pretakeoff passenger briefing required by§ 121.571 of this chapter may be given. The passengers may also be advised to follow directions of crewmembers, but not be instructed on the procedures to be followed in the demonstration.

(16) If safety equipment as allowed by paragraph (c)(3) of this section is provided, either all passenger and cockpit windows must be blacked out or all of the emergency exits must have

safety equipment in order to prevent disclosure of the available emergency exits.

(17) Not more than 50 percent of the emergency exits in the sides of the fuselage of an airplane that meet all of the

requirements applicable to the required emergency exits for that airplane may be used for the demonstration. Exits that are not to be used in the demonstration must have the exit handle deactivated or must be indicated by red lights, red tape, or

other acceptable means, placed outside the exits to indicate fire or other reason why they are unusable. The exits to be used must be representative of all of the emergency exits on the airplane and must be designated by the applicant, subject to approval by the Administrator. At least one floor level exit must be used.

(18) All evacuees, except those using an over-the-wing exit, must leave the airplane by a means provided as part of the

airplane's equipment.

(19) The applicant's approved procedures must be fully utilized during the demonstration.

(20) The evacuation time period is completed when the last occupant has evacuated the airplane and is on the ground. Provided that the acceptance rate of the stand or ramp is no greater than the acceptance rate of the means available on the

airplane for descent from the wing during an actual crash situation, evacuees using stands or ramps allowed by paragraph

(c)(3) of this section are considered to be on the ground when they are on the stand or ramp.

(d) A combination of analysis and test may be used to show that the airplane is capable of being evacuated within 90 seconds under the conditions specified in§ 25.803(c) of this chapter if the Administrator finds that the combination of analysis and tests will provide data with respect to the emergency evacuation capability of the airplane equivalent to that which would be obtained by actual demonstration.

b. Guidance.

(1) Paragraph (c){l7). One exit from each pair of exits may be used to satisfy the 50 percent requirement.

(2) Paragraph (d). Evacuation analyses should be based on actual demonstrations used to show compliance with§§ 25.803 or 121.291 and/or other

appropriate tests. If the test data is available, and applicable to the additional configuration, analysis may be conducted. The analysis should include consideration of exit size and distribution; slide deployment times and evacuee evacuation rates; analysis of critical passenger flow points i.e. door, aisle, slide, for evacuation rate limiting factor; expected evacuee behavior (hesitation, etc.) as observed on previous tests; and any other consideration pertinent to the particular model airplane.

278-300. [RESERVED]

278-300. [RESERVED]

Par 277 459 (thru 500)

SECTION 25.805 FLIGHTCREW EMERGENCY EXITS

301. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

Except for airplanes with a passenger capacity of 20 or less in which the proximity of passenger emergency exits to the

flightcrew ar~a offers a convenient and readily accessible means of evacuation for the flightcrew, the following apply:

SECTION 25.805 FLIGHTCREW EMERGENCY EXITS

(a) There must be either one exit on each side of.the airplane or a top hatch, in the flightcrew area.

{b) Each exit must be of sufficient size and must be located so as to.allow rapid evacuation of the crew. An exit size and shape· of other than at least 19 by 20 inches unobstructed rectangular opening may be used only if exit utility is satisfactorily shown, by a typical flight crewmember, to the Administrator.

b. Guidance. The demonstration required for acceptance of other than at least a 19 by 20-inch opening should be accomplished by at least a 95 percentile male (74 inches tall, and weighing 210 pounds) with at least analytical consideration to the effects of the failure of one or more landing gear~

302-320. [RESERVED]

302-320. [RESERVED]

Par 301 501 (thru 520)

SECTION 25.807 PASSENGER EMERGENCY EXITS

321. REGULATION IN EFFECT AT ADOPTION OF PART 25.

a. Regulation.

(a) Type and location. For the purpose of this Part, the types and locations of exits are as follows:

(1) Type I. This type must have a rectangular opening of not less than 24 inches wide by 48 inches high, with corner radii not greater than 1/3 the width of the exit. The first Type I exit on each side of the fuselage must be in the rearward part of the passenger compartment unless another location affords a more effective means of passenger evacuation. Type I exits must be

SECTION 25.807 PASSENGER EMERGENCY EXITS

floor level exits.

(2) Type II. This type must have a rectangular opening of not less than 20 inches wide by 44 inches high, with corner radii not greater than 1/3 the width of the exit. Unless Type I exits are

required, one Type II exit on each side of the fuselage must be in the rearward part of the passenger compar~ment unless another location affords a more effective means of passenger evacuation. Type II exits must be floor level exits unless located over the wing, in which case they may not have a step-up inside the

airplane of more than 10 inches nor a step-down outside the airplane of more than 17 inches.

(3) Type III. This type must have a rectangular opening of not less than 20 inches wide by 36 inches high, with corner radii not greater than 1/3 the width of the exit, located over the wing, with a step-up inside the airplane of not more than 20 inches and .

a step-down outside the airplane of not more than 27 inches.

(4) Type IV. This type must have a rectangular opening of not less than 19 inches wide by 26 inches high, with corner radii not greater than 1/3 the width of the exit, located over the wing, with a step-up inside the airplane of not more than 29 inches and

a step-down outside the airplane of not more than 36 inches. Step-down distance, as used in this section, means the actual distance between the bottom of the required opening and a usable foothold, extending out from the fuselage, that is large enough to be effective without searching by sight or feel.

(b) Accessibility. Each required passenger emergency exit must be accessible to the passengers and located where it will afford the most effective means of passenger evacuation. Openings larger than those specified in this section, whether or not of rectangular shape, may be used.if--

(1) The specified rectangular opening can be inscribed within the opening; and

AC 25-17

(2) The base of the inscribed rectangular opening meets the specified step-down heights.

(c) Passenger emergency exits; side-of-fuselage. The exits prescribed in this paragraph need not be diametrically opposite each other, but must .be provided as follows:

(1) Except as provided in subparagraphs (2) through (5) of this paragraph, the number and type of passenger emergency exits must be in accordance with the following table: ·

Emergency exits for

Passenger seating

capacity

each

Type

I

side of

Type

II

the fuselage

Type Type III IV

1 through 10 I through 19 2 through 39 -------- ------ … -----1 -------- ------ 1 ------ -------- 1 … 1 1 ------ ------ 1 40 through 59 60 through 79 80 through 109 1 ------ 1 … 1 ------ 1 1 110 through 139 140 through 179 }80 through 219

2 ------ 1 -------- 2 ------ 2 ------ 2 ------ 2 …

(2) Two Type IV exits may be installed instead of each required Type III exit.

(3) Additional exits, providing an effective means of passenger evacuation consistent with the minimum number prescribed in subparagraph (1) of this paragraph are required for airplanes with a passenger capacity of 220 or more.

(4) If there are additional emergency evacuation means on the airplane, the passenger/emergency exit relationship may be

increased by not more than 10 passengers beyond the limits specified in subparagraph (1) of this paragraph. If this means is an approved inflatable slide installed at each floor level exit (other than over-the-wing exits), the passenger/emergency exit relationship may be increased by--

(i) ·Not more than five passengers on airplanes with at least two of these exits; and

(ii} Not more than 10 passengers on airplanes with at least four of these exits.

(5) For airplanes on which the vertical location of the wing does not allow the installation of over-the-wing exits, an exit of at least the dimensions of a Type III must·be installed

instead of each Type III and each Type IV exit required by subparagraph (1} of this paragraph.

(d) Ditching emergency exits. In addition to the requirements of paragraph (c} of this section, the following apply:

(l} There must be at least one emergency exit for each unit (or part of a unit} of 35 passengers, but no less than two such exits, both above the waterline with one on each side of the airplane, meeting the minimum dimensions of--

(i} A Type IV exit for airplanes with a passenger seating capacity of 10 or less; and

(ii} A Type III exit for airplanes with a passenger seating capacity of 11 or more.

(2} If side exits cannot be above the waterline, the side exits must be replaced by an equal number of overhead hatches of not

less than the dimensions of a Type "III exit except that, for airplanes with a passenger capacity of 35 or less, the two required Type III side exits need be replaced by only one overhead hatch.

{3} Two Type IV exits may be installed instead of each required Type III exit.

b. Guidance.

(l} The equivalency to that required by the regulations of nonstandard exits or arrangements may be determined by use of the Latin-Square test procedure. See Appendix 4 which was derived from Notice FS 8110.12, May 21, 1964, "Test Procedure for Evaluating Non-Standard Exits for Transport Category Airplanes."

(2) Paragraphs (c) and (d). An airplane design is determined to be eligible for a certain passenger seating complement which is commensurate with meeting all of the relevant portions of§ 25.807. That is, in addition to meeting the table of§ 25.807(c}(l), the eligibility complement is also governed by the ditching requirements of§ 25.807(d}, whether certification for ditching is requested or not.

(3) Paragraph (c) and (d). Flight attendants are considered part of the crew and are not included in the passenger seating capacity mentioned in § 25.807(c) and (d).

Par 321 523

322. AMENDMENT 25-15, Effective October 24, 1967.

a. Change to Regulation.

{a) Type and location. For the purpose of this Part, the types and locations of exits are as follows: