AC 21-16G RTCA Document DO-160 versions D, E and F, “Environmental Conditions and Test Procedures for Airborne Equipment”

a. This advisory circular (AC) identifies RTCA Document No. (RTCA/DO)-160 versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment, dated July 27, 1997, December 20, 2005, December 6, 2007, and December 8, 2010, respectively, as containing acceptable environmental qualifications to show compliance with certain airworthiness requirements. The FAA strongly encourages the use of RTCA/DO-160G for new articles. b. Appendix 1 of this AC provides a summary of the changes from RTCA/DO-160C to RTCA/DO-160D, version D to E, version E to F, and F to G. The information in the table will assist you in determining if a particular version of RTCA/DO-160 is acceptable.

Official source ↗ Open PDF

Advisory

U.S. Department of Transportation Circular Federal Aviation Administration

Date: 06/22/2011 AC No: 21-16G Subject: RTCA Document DO-160 versions D, E, F, and G, “Environmental Conditions Initiated by: AIR-100 and Test Procedures for Airborne Equipment”

1. What is the purpose of this Advisory Circular?

a. This advisory circular (AC) identifies RTCA Document No. (RTCA/DO)-160 versions D, E, F, and G, Environmental Conditions and Test Procedures for Airborne Equipment, dated July 27, 1997, December 20, 2005, December 6, 2007, and December 8, 2010, respectively, as containing acceptable environmental qualifications to show compliance with certain airworthiness requirements. The FAA strongly encourages the use of RTCA/DO-160G for new articles.

b. Appendix 1 of this AC provides a summary of the changes from RTCA/DO-160C to RTCA/DO-160D, version D to E, version E to F, and F to G. The information in the table will assist you in determining if a particular version of RTCA/DO-160 is acceptable.

Note: When reference to RTCA/DO-160D is made in this AC, it includes Changes 1, 2, and 3, dated December 14, 2000, June 12, 2001, and December 5, 2002, respectively.

c. This AC is not mandatory and does not constitute a regulation. This AC describes a means, but not the only means, to comply with airworthiness requirements.

2. To whom does this AC apply? This AC applies to manufacturers and installers that use RTCA/DO-160 for environmental qualifications of their airborne equipment.

3. Cancellation. This AC cancels AC 21-16F, RTCA Document DO-160 versions D, E, and F, Environmental Conditions and Test Procedures for Airborne Equipment, dated November 19, 2009.

4. What is RTCA/DO-160?

a. RTCA/DO-160 (or its precursor, RTCA/DO-138) has been used as a standard for environmental testing since 1958. It defines standard environmental test conditions (categories) and applicable test procedures for airborne equipment.

06/22/2011 AC 21-16G

b. The tests in RTCA/DO-160 provide a laboratory means of demonstrating the performance characteristics of airborne equipment in environmental conditions that may be encountered in operation of the equipment in aircraft. It is not the intent of RTCA/DO-160 to be used as a measure of service life of the airborne equipment subjected to these tests.

c. As the realities of equipment operation under actual environmental conditions are better understood and new needs arise within the aviation community, RTCA/DO-160 has been revised to address the emerging and improved test techniques. The categories that have been developed over time reflect a reasonably mature understanding as to the severity of the environmental stresses, the degrees of mitigation achievable in the design of an installation, and the robustness that must be designed into equipment in order to perform in the operating environment.

5. Related Documents.

a. Title 14 of the Code of Federal Regulations, (14 CFR) parts 21, 23, 25, 27, 29, 33, and 35.

b. AC 20-136, Protection of Aircraft Electrical/Electronic Systems Against the Indirect Effects of Lightning.

c. AC 20-158, The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment.

d. AC 20-138, Airworthiness Approval of Positioning and Navigation Systems.

e. AC 33.17-1, Fire Prevention.

6. Using RTCA/DO-160 for Technical Standard Orders (TSOs).

a. If you are an applicant seeking a TSO authorization for airborne equipment, you may request a deviation, in accordance with the requirements of 14 CFR part 21 subpart O, to use the conditions and procedures in a different version of RTCA/DO-160 instead of the corresponding conditions and procedures specified in the applicable TSO. Although an applicant may request to use an earlier version of DO-160, we recommend that you use RTCA/DO-160G.

b. If the TSO does not specify the environmental qualification, the applicant may choose any environmental standard conditions and test procedures appropriate for their airborne equipment. Although an applicant may choose any environmental standard, we recommend that you use RTCA/DO-160G.

c. The table in Appendix 1 of this AC provides sufficient data for an applicant to use as a comparison between RTCA/DO-160D, E, F, and G. The FAA has determined that versions D, E, F, and G provide an equivalent level of safety (ELOS) when the applicable version is identified in the Environmental Qualification Form (EQF). If the installed electrical/electronic equipment must meet lightning requirements use RTCA/DO-160D or later per the latest revision of AC 20-136. However, if the installed equipment is expected to be subject to HIRF

06/22/2011 AC 21-16G

requirements in §§ 23.1308, 25.1317, 27.1317, or 29.1317, use RTCA/DO-160F or G. RTCA/DO-160E is also acceptable to meet the HIRF requirements for level B and C systems when using test levels defined in the appropriate regulations as discussed in AC 20-158.

d. If the version of RTCA/DO-160 specified in a TSO is version D or later, and an applicant wishes to use a version prior to RTCA/DO-160D, then the applicant must meet the requirements of paragraph 6a by comparing the specific procedure and category changes, section by section, between the two versions. The applicant must also address the differences between the two test results when providing an equivalent level of safety.

e. When a new application is based on the design of an existing approved article, the applicant may ask to use environmental test data from the existing article’s environmental qualification, based on similarity between the two articles. This request must be fully supported with a detailed similarity assessment comparing the changes from the earlier approved article to the article in the new application. The aircraft certification office (ACO) may accept the data if the similarity assessment clearly shows that the design changes will not adversely affect the environmental qualification.

f. When the equipment or its associated wiring has the likelihood to be located in areas close to global positioning system (GPS) antennas, we recommend you use DO-160F section 21 category P or DO-160G section 21 categories P or Q, to reduce potential RF noise in the GPS band. For additional guidance on GPS equipment, refer to the latest revision of AC 20-138.

7. Using RTCA/DO-160 for Installers.

a. If you are an applicant installing equipment, you may use RTCA/DO-160, any version, to support compliance with the appropriate airworthiness requirements except as identified in paragraphs 7c, 7f, 7g, and 7h. When possible, we recommend that you use RTCA/DO-160G as it provides the most clear and complete test procedures.

b. Use the EQF provided by the equipment manufacturer to compare against your specific installation requirements. The EQF provides information regarding which version of DO-160 was used, which environmental tests were conducted and the environmental category of the equipment being tested. If the EQF categories do not adequately address your installation, then you or the equipment manufacturer may need to re-qualify the equipment to meet the appropriate sections and category levels.

c. When installing equipment previously qualified to other environmental standards, such as Military Standard (MIL-STD) 810G, the equipment must comply with applicable airworthiness requirements. You may use DO-160G to do a comparison analysis to show that it provides an equivalent level of safety in the expected operating environment.

d. When a new application is based on the design of an existing approved article, the applicant may ask to use environmental test data from the existing article’s environmental qualification, based on similarity between the two articles. This request must be fully supported with a detailed similarity assessment comparing the changes from the earlier approved article to

06/22/2011 AC 21-16G

the article in the new application. The ACO may accept the data if the similarity assessment clearly shows that the design changes will not adversely affect the environmental qualification.

e. Some of the environmental conditions and test procedures contained in RTCA/DO-160 such as waterproofness, sand and dust, or salt fog, may not be applicable to your installation based on intended location of the equipment. You must determine which sections and categories are applicable to your specific project.

f. When the equipment installation is required to meet the HIRF requirements in §§ 23.1308, 25.1317, 27.1317, or 29.1317, use RTCA/DO-160F or G. RTCA/DO-160E is also acceptable to meet the HIRF requirements for level B and C systems when using test levels defined in the appropriate regulations as discussed in AC 20-158. For additional guidance on HIRF, refer to the latest revision of AC 20-158.

g. When the electrical/electronic equipment installations are required to meet lightning requirements, use RTCA/DO-160D or later. For additional guidance on lightning, refer to the latest revision of AC 20-136.

h. RTCA/DO-160F, Section 26, Fire, Flammability, is not sufficient for 14 CFR parts 25 and 33. RTCA/DO-160G, Section 26, is sufficient for 14 CFR part 25 but not for 14 CFR part 33. Fire and flammability guidance for 14 CFR part 33 is provided in the latest revision of AC 33.17-1.

8. How To Get Related Documents.

a. Order copies of RTCA documents from RTCA, Inc, 1150 18th Street, NW, Suite 910, Washington, DC 20036-4007, telephone (202) 833-9339, fax (202) 833-9434. You can also order copies online at http://www.rtca.org.

b. Order copies of 14 CFR parts from the Superintendent of Documents, Government Printing Office, P.O. Box 979050, St. Louis, MO, 63197-9000. For general information, telephone (202) 512-1800 or fax (202) 512-2250. You can order copies from the Government Printing Office website at http://bookstore.gpo.gov. Select “Code of Federal Regulations.”

c. View a list of all ACs on the FAA’s Regulatory and Guidance Library at www.rgl.faa.gov or from the website at www.faa.gov/regulations_policies/advisory_circulars/.

David W. Hempe Manager, Aircraft Engineering

Division

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

Summary of changes between DO-160D, E, F, and G

RTCA/DO-160 will continue to be subject to revisions as needs arise in the aviation community. However, it is not always feasible

for an applicant to use the more current revision. The following table is a summary of the changes made from RTCA/DO-160C to D,

Appendix 1

D to E, E to F, and F to G. Versions of RTCA/DO-160 prior to RTCA/DO-160D are also not included in this table. The information

in the table should help you determine if your new article should be subject to a particular version of RTCA/DO-160.

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

Section 1-Section

Section 1-Section

3: Purpose and

Applicability,

Definitions of

Terms, and

Conditions of

Tests

Editorial and clarifications

changes only. Section 3: The requirement for

cumulative testing of

Temperature, Altitude,

Humidity, and Vibration was

removed, and clarification was

added with respect to the use of

multiple test articles.

Added section 2.9,

Applicability of Test Results

and section 3.9, EUT

Configuration for

Susceptibility Tests.

Section 2: Clarification added with

Section 2: Clarification added with

respect to applicability of lesser

categories when equipment is

qualified to a more severe category.

Section 3: Reference to paragraph

21.5 was removed. Clarification added on the use of special purpose

software to place the equipment in

its most susceptible mode.

Section 3: Reference to paragraph

Requirement added for operation of

equipment in its most susceptible

mode for all environmental tests, not

just susceptibility tests.

Temperature and

Altitude

Section 4.3 Equipment

Categories added reference

categories for in-flight loss of

cooling test.

Section 4.5 Temperature Test

Section 4.5 Temperature Test

was restructured to include sub­

section 4.5.2 Operating Low

Temperature.

Section 4.5.3 Ground Survival

High Temperature Test and

Short Term Operating High

Temperature Test clarified

soak time upon reaching short

time operating low and high

temperature. Section 4.5.5,

In-Flight Loss of Cooling Test

Section 4.5.3 Ground Survival

Clarified paragraph 4.5.1, Note 2

and paragraph 4.5.3, Note 2.

1 Includes Changes 1, 2, and 3 to RTCA/DO-160D.

A-1

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

in the note clarified cooling

Appendix 1

source and power.

Section 5: Section 5.3 Test Procedures Section 5.2 Temperature Change Sections, 5.3.1h, 5.3.2h, and Paragraph 5.1 – Added note

Temperature was revised to provide Rates added two temperature 5.3.3i, changed the clarifying test intent and humidity

Variation provisions for collecting data

during a single cycle of test

and reduced data collection

under certain test conditions.

shock tests, categories S1 and

S2, and Sections 5.3.2 and 5.3.3

are the tests sections that

accompany the newly added

categories, respectively.

performance compliance

timing to be in the second, or

last cycle.

control. Paragraphs 5.3.1a and d –

added clarification of temperature

change procedure for Operating

Low and Operating High

Temperatures.

Section 6: Editorial changes were made Section 6.3 was modified to In paragraphs 6.3.1, 6.3.2, and Corrected terminology paragraph

Humidity to eliminate redundant

description of the test

procedures. Velocity of air

throughout the exposure area

changed from “Shall not

exceed 0.75 m/s” to “Between

0.5 and 1.7 m/s”. Alternative method was added to measure

the water pH.

allow a + 4 percent tolerance to

the relative humidity

requirement.

6.3.3 changed step 2 to 38 degrees to agree with

corresponding figure.

6.3, removed word hydroxide.

Section 7: Equipment category Fixed wing and helicopter Category definitions were Added in Section 7.2.1 “Unless

Operational definitions were added for operational and crash safety test revised for clarification. Text otherwise stated in the EUT

Shocks and fixed wing and helicopter requirements were made the description and centrifuge specification, the equipment shall be

Crash Safety installations. Crash Safety

levels were identified for

helicopters (20g) and

increased for fixed wing crash

safety levels (20g). Shock

pulse was changed from half

sine to saw tooth. Half-sine

shock pulse curve changed to

reflect saw-tooth profile. Test

levels were changed from DO­

160C based on empirical data.

same. definitions were revised in

section 7.3.3 and figure 7.3,

respectively, to reflect the

correct setup direction for

acceleration load.

operating, and its temperature

stabilized. Apply to the test item

three shocks having a terminal saw­

tooth wave shape with an

acceleration peak value of six (6) g's

in each orientation."

A-2

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

Vibration New section defining

vibration requirements for

helicopters was added.

Random vibration levels were

changed by the addition of

new curves. Tables and

figures were modified to

support changes in test levels.

Fixed Wing Zone 2 features two

new test curves. High Level

Short Duration Category Test

was revised. Helicopter

endurance test times were

reduced and the unknown

helicopter test procedure was

reconfigured (Category U).

Unknown helicopter test

procedure (Category U2) was

added as an alternative to

revision D.

Performance test times were

reduced from 30 minutes to a

minimum of 10 minutes.

Robust test equipment

operating, not operating

requirements were

standardized to have

equipment not operating

during sinusoidal scans and

operating during the robust

test portion of the test, unless

specified otherwise by the

applicable equipment

specifications.

Deleted in section 8.8 "Caution

should be exercised regarding wear

/damage occurring during the tests

to DZUS (c) fasteners or other

flexible mounting devices."

Editorial change "Repeat the

sinusoidal scan of subparagraph

8.8.1.3.a."

Section 9: Fuel mixture calculation was Minor changes were made in the Environment definition and The environment descriptions are

Explosion corrected for hexane explosive procedure to improve category definitions were improved and category description

Proofness proofness test. Atmospheric repeatability. revised. Reference to 100/130 details are moved to the users guide.

test pressure requirements octane fuel was deleted from The sensor for determining the

were clarified. figure 9-4. explosiveness of the environment is

changed from a spark plug or glow

plug to a pressure sensor or

thermocouple. Also, the

containment test was changed such

that if the test case volume is greater

than 1/50 of chamber volume an

alternative to purging entire

chamber would be to prove

explosive mixture is correct after

each case explosion.

Section 10: Test step that verifies absence Minor improvements to pre-heat Drip Rate was changed from In Figure 10-1, the 75 mm height of

Waterproofness of water penetration into test unit and to reduce risk of 280 l/m2/hr to 140 l/m2/hr. water annotation is superseded by a

unit following test was deleted thermal shock were made. new note that states the volume of

because it was not consistent water emitted from the drip table

with intent and purpose of test. must be pre and post calibrated and

The test is intended to verify the level of water in the drip table

performance of unit following noted.

exposure to this environment,

not to verify the unit’s ability

A-3

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

to keep out water.

Section 11: Table 11-1 eliminated Updated list of fluids and added No changes were made. Added 2 new fluids - Cleaning fluid

Fluids reference to fire inspection. - 1-2 Dichloroethlene; and Fire

Susceptibility extinguishants and add

additional de-icing fluid,

propylene glycol. Aircraft fire

extinguishants are gaseous and

do not exist in liquid form

under normal conditions. De­

icing fluid added to reflect

current industry practices.

extinguishant, Aqueous Film

Forming Foam (ATTF) to fluids list.

Changed spray test to align with

MIL STD 810G - spray 8 hours,

followed by 16 hours of drying,

repeated 3 times. Change operation

of unit while wet after 24 hour spray

to while wet at end of third 8-hour

spray segment, and third change

requirement of operation of unit at

end of each fluid drying period from

2 hours to 30 minutes minimum or unit stabilized.

Section 12: Editorial and clarifications Sand and dust were separated Category definitions were Change sand composition particle

Sand and Dust changes only. into two categories. Update the

mixtures to current commercial

available characteristics.

revised for clarification.

Additional sand

concentrations were added.

Size distributions and sum of

total percentages to 100%

were adjusted in Section

12.3.2.

size to meet MIL STD 810G

requirements.

Section 13: Section 13.5.7 was revised to Other causes of fungus other Magnesium sulfate was No changes were made.

Fungus eliminate 48 hour period after than nutrient materials and adjusted to align with other

Resistance removal from chamber before

performance test. personnel safety caution were

added.

Test failure criteria were

clarified.

ingredients.

Section 14: Change functional test criteria. Title of section was changed Changed term Salt Spray to Add alternating periods of exposure

Salt Fog Functional test may now be

performed following 48 hour

dry-out period.

from Salt Spray to Salt Fog.

Category T was added for severe

salt atmosphere.

Salt Fog throughout this

section. and drying. Suppress the drying

before power up for Category T.

Magnetic Effect Text was added to clarify

source of referenced magnetic Section 15.3 was modified to

provide a more detailed test A new Category Y was added

for measurements made Added user’s guide and updated

figure 15-1.

A-4

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

field. procedure than in previous

versions, including a

requirement to verify field

uniformity if the compass must

be moved to change the

measurement distance to the

EUT (equipment under test). The

new Figure 15-1 provides a test

setup diagram and gives notes on

proper performance of the test.

immediately adjacent to the

unit under test. Descriptions

of each equipment category

were added to Section 15.1

Purpose of Test along with

discussion of how the test

results are used to determine

how close the EUT may be

installed to a compass or

compass sensor. Text allowing

the measurements to be made

with an uncompensated

compass or equivalent

magnetic sensor was also

added.

Section 16: Change 2 to DO-160D, The entire section was re- More tests are required for Added alternate test "Z" for ac

Power Input published June 12, 2001,

revised Section 16, by

including new tests, and

modifications to existing

testing, to address the issues of

AC harmonic current content

and variable frequency AC

power systems.

ordered so that all the AC tests

were in one subsection and all

DC tests were in another

subsection, making Section 16

easier to use and understand.

DO-160E also introduced some

new tests, such as a DC content

test for AC powered equipment,

and a new subsection covering

"Load Equipment Influence on

Aircraft Electrical Power

Systems."

both AC and DC powered

equipment. A 270V DC bus

generated from the A (WF)

AC power bus was added as

Category D. Discrete step test

methods were defined for AM

and FM modulation on AC

systems. AM voltage

modulation on AC buses was

increased. Double interrupt

test methods were added for

DC equipment. Manual reset

was explicitly not permitted

after single and double power

interrupts. The dwell at 28V

between the short and the long

dc voltage surge was removed.

Loss of phase testing was

added for three phase. A

Power Factor test designation

was added for ac equipment.

DC current draw tests from

inrush tests. Clarified peak current

definition in inrush testing. Allow

performance of emergency limits for

Category A(CF) equipment to

constitute performance of normal

(part c.(1)) test conditions. Allow

performance of emergency limits to

constitute performance of normal

(part b.(2)) test conditions. Added

equipment with analog circuitry to

be tested with the test conditions of

Table 16-1 and Table 16-3.

A-5

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

AC equipment current were

added. In-rush and current

modulation test designations

were added for both AC and

DC equipment. Tolerances

were added to most tests.

Category H, harmonic

emissions, measurement

methods were updated.

Section 17: Editorial changes were made No significant changes were Section 17.4 Test Procedures Editorial changes only.

Voltage Spike to support document

consistency. Reference to

"DC only" condition was

eliminated thereby expanding

applicability to both AC and

DC systems. Figures were

modified to accommodate the

inclusion of AC power

systems. Reference to

negative pulse generation

network was eliminated.

made. was modified to clarify

application of positive and

negative transients over the

specified period of time. Test

conditions were clarified when

multiple power pins are

present.

Section 18: DO-160C referenced Figures The equipment category New test for 270V dc input Changed secondary limit from a

Audio Frequency 16-4 and 16-5 for DC ripple designators A and J were differential ripple to follow 1000W power limit to a 36A (pk- Conducted test requirements; these eliminated, and categories R and same curve as 28V Category pk) current limit. Added user’s

Susceptibilityfigures were moved to Section K were added. Z, but at 4 times the amplitude guide and moved appropriate

Power Inputs 18 as Figures 18-2 and 18-3. was added. A common mode

noise test has been added for

270V Category Z equipment. For test equipment that

generate a continuous linear

frequency sweep, the

minimum (i.e., fastest) sweep

rate has been slowed to make

swept testing equivalent to

stepped testing, especially at

resonances. An optional DC

blocking network is added to

the test setup figures to

material to the guide. Corrected

minor issues in existing figures.

A-6

06/22/2011 AC 21-16G

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

prevent damage to the signal

source.

Section 19: Category C was added to A second equipment category Clarification to existing Clarified that power leads are tested

Induced Signal include test levels that are designator was added to indicate formula used to calculate test per section 18. Clarified radiating

Susceptibility appropriate for installations

with long wire runs or

minimum wire separation.

The test levels for magnetic

and electric fields induced into

wiring were increased.

the AC power system operating

frequency (Constant, Narrow

Variable, or Wide Variable).

The frequency scan rate was

changed to 30 steps per decade,

with a 10-second dwell time at

each frequency.

frequencies was made. wire orientation for “Magnetic

Fields Induced Into the Equipment”

test. Added “Electric Fields

Induced Into the Equipment” test.

This test is similar to the existing

“Magnetic Fields Induced Into the

Equipment” test, using an open-

circuit wire radiator. This change

caused paragraph re-numbering

within this section, including those

paragraphs of existing tests.

Clarified source wire routing (spiral

vs. parallel) relative to bundle under

test.

Section 20: The revisions to Section 20, in A section providing guidance Test categories were reduced Indicated that section categories are

Radio Frequency DO-160D Change No.1, and caution related to RF power and “alternative” modulations appropriate for Transmitting

Susceptibility published December 2000, amplifier harmonics and their for Category R were Portable Electronic Device.

(Radiated and include a new, Mode-Tuned, potential to affect the test results eliminated. There is now only Clarified that power lines may, but

Conducted) Reverberation Chamber

Radiated RF Susceptibility

test method. New categories

(test levels) were also added to

Section 20, including

Section 20, including

Category L, which requires

Radiated RF Susceptibility

testing (pulsed) as high as

7200 volts/meter.

An alternate procedure was

added for mode-stirred

radiated susceptibility tests.

The mode-stirred procedure

was accepted as an alternate

that may require lower-power

was added, along with a revision

that allows the use of an

oscilloscope to measure

Conducted Susceptibility test

levels. The Mode-Tuned test

method for Radiated

Susceptibility was modified to

allow for the option of using the

received power on the monitor

antenna to determine the test

level, as opposed the E-field

readings from a 3-axis sensor.

Flexibility in the number of

tuner steps was also added,

giving the user the choice of

increasing the number of steps

one test method for conducted

susceptibility. Clarification

has been added regarding the

requirement to expose all

apertures and openings of the

EUT in anechoic chamber

method. RTCA/DO-160F

added requirements to test

several additional dwell

frequencies where the image

frequencies for n =2 through

10. 160F removed the permissive language

associated with these tests. It

used to be “should” but 160F

now uses “shall”.

are not required to, be routed with

interconnect wiring, unless this

conflicts with aircraft installation

specifications. Indicated that the

radiating antenna may be placed

further than 1 meter from EUT.

Significant change to reverberation

chamber testing made by replacing

“Mode Tuning” test technique with

“Mode Stirring” technique.

A-7

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

amplifiers. based on the need for greater

field uniformity or a higher test

level, or decreasing the number

of tuner steps to decrease the test

time.

Emission of

Radio Frequency

Energy

Change Category Z

requirements to reflect need

for additional scrutiny in the

VHF COM NAV and GPS

frequencies.

All of the figures were cleaned

up and made easier to read. The

Radiated Emissions limits for

Categories M and H were

modified slightly so that the

notches that occur in various

frequency ranges now have

sloped bottoms to match the rest

of the limit. The frequency range

of the first notch has also been

changed for a more precise

match with the

communications/navigation

frequency range that the notch

protects.

The conducted emissions

frequency range has been

broadened to 150 kHz - 152

MHz, and the Radiated

Emissions test frequency

range has been narrowed to

100 MHz - 6 GHz. A new procedure for radiated

emissions measurements in a

reverberation chamber was

added. In the anechoic

chamber method, clarification

has been added regarding the

requirement to expose all

apertures and openings of the

EUT. A new limit category

has been added, Category P, to

provide added protection for

certain receivers by use of

even deeper notches than

previously used.

Added optional in-line low noise

preamp to diagrams in Fig. 21-11,

Fig. 21-12, and Fig. 21-13 per

description in Table 1, Note 1.

Corrected values at 152 MHZ notch

points, 37.5dB in Fig. 21-8, 27.5 dB

in Fig. 21-9, and 27.5 dB in Fig.

21-10. Added acronym definitions for GPS and GNSS at first

21-10. Added acronym definitions for GPS and GNSS at first

occurrence of acronym in Section

21. Added verbiage in Section 21 User Guide discussing the use of

equivalent dipole directivity in

formula found in Section 21.6.3.i.

Revised Figure 21.6 and 21.11 to

show bends in the cable bundle as it

21. Added verbiage in Section 21 User Guide discussing the use of

exits the EUT. Revised frequency

ranges in Table 1: 100 kHz

bandwidth upper frequency limits =

0.4 - 0.96 GHz and 1 MHz bandwidth lower frequency limits =

0.96 – 6.0 GHz. Revise Note 1 to Table 1 to eliminate the option to

use an uncorrected 10 kHz

bandwidth in the measurement of

category M & H emission notches

above 960 MHz. Substituted a new

Note 1 which recommends use of a

low noise preamplifier if necessary

to achieve sufficiently low

measurement noise floor in the

notches. Added Category Q.

Revised Paragraph 21.2 to include

A-8

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

Category Q definition. Inserted two

new Figures for Category Q, Fig.

21-4 and Fig. 21-5. Renumbered remaining figures as required.

Added Section 21 User Guide to

Section 21.

Section 22: DO-160D Change No. 3, The DO-160E cable bundle test Section 22 was restructured The most significant change to

Lightning published December 2002, section was modified to include with additional test Section 22 in DO-160G is the

Induced added additional waveform a new section providing requirements moved from addition of a User’s Guide (UG) as

Transient sets, cable bundle test levels, guidance for performing cable notes under figures to the main an appendix to Section 22. This

Susceptibility and the procedures for

performing indirect lightning

multiple stroke and multiple

burst tests using the existing

defined test waveforms. The

category designations were

modified to allow users to

designate categories that

indicated that these additional

tests had been performed.

New Waveform Set

designators, G through K,

were added to cover the

Multiple Burst and Multiple

Stroke tests.

Another significant addition to

Change 3 was setup

information on performing pin

injection tests with power

applied. Several different

setup diagrams were added to

assist users in performing

these tests properly.

Improperly connecting the

lightning generator to a pin

with power applied could

result in insufficient stress on

the pin.

bundle tests on bundles that

normally contain shields, with

the shields removed. This

guidance allowed testing of a

cable bundle at test levels

currently defined in DO-160, but

intended to demonstrate

compliance to aircraft

installation threats that are

higher than these standardized

levels. It explicitly stated that

the test generator used for cable

bundle testing does not need to

be capable of producing the

voltage or current limit level,

provided that the current or

voltage test level can be

achieved on the cable under test.

body of the document, and

paragraphs were numbered to

provide easy reference to the

requirements contained in

each paragraph. In the

waveform set tables and the

test level tables, both the

voltage and the current

waveform number are now

shown to eliminate any

ambiguities with how

waveforms are related to each

other.

This section was modified to

clarify when a test was

successfully completed and

when, in the case of reaching a

limiting level before a test

level, another waveform test

was needed. The cable bundle

section now contains a path to

follow for every waveform set

and criteria for acceptable and

unacceptable test limit

waveforms that leads the user

to successful test completion

regardless of the configuration

of the cable under test.

appendix removes guidance material

from the requirements portion of the

section. This allows for an in-depth

discussion on relevant topics

without “muddying” the procedures

and test level definitions contained

in the requirements portion of

Section 22. The UG format is a

Section 22. The UG format is a

paragraph by paragraph match with

the requirements section for easy

references to guidance on specific

topics. Where no guidance material

was added, the UG paragraph is not

populated. It is expected that the

UG will assist equipment designers

with design and test considerations

as well as improve standardization

of testing between test facilities.

For example, by providing a

detailed discussion on dealing with

noise during waveform

measurements, labs are more likely

to use the same methodology for

making measurements, resulting in

much more consistency across the

industry.

The DO-160G Section 22

A-9

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

requirements portion adds the test

methods and test levels for

performing Waveform 6 Multiple

Burst testing. Voltage limits for

Waveform 6 are based on the open

circuit voltage level from Waveform

3 Pin Injection, as Waveform 6, by definition, does not have a voltage

3 Pin Injection, as Waveform 6, by definition, does not have a voltage

limit. The Waveform 6 Multiple

Burst test resulted in the addition of

another waveform set character to

identify the waveform used for

Multiple Burst testing. Waveform

set ‘L’ is used to identify Waveform

3 Multiple Burst and waveform set ‘M’ identifies Waveform 6 Multiple

3 Multiple Burst and waveform set ‘M’ identifies Waveform 6 Multiple

Burst.

Due to potential inconsistencies

between the two Pin Injection test

calibration methods, the resistor

method was removed. The open

circuit voltage/short circuit current

method is considered the preferred

method. As a result of the method

elimination, several test setup

diagrams were updated to reflect the

change.

Clarification was added for the use

of the ‘Z’ designator when the

waveform generator is switched

because the generator used did not

produce a compliant ‘limit’

waveform. It is now specified that

switching generators requires that

the waveform set designation be a

‘Z’, the only exception being where

A-10

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

this is done for power line testing

only. Testing of the power line

separate from a standard

interconnect bundle is the most

common way of testing, therefore

the exception is allowed providing

better representation of the

waveform set used for testing on the

EUT interconnect bundle.

Lightning Direct

Effects

Additional procedure with

associated electrode was

provided for producing

flashover when flashover is

not produced during the

normal procedure and it is

desired that flashovers occur.

No significant changes were

made. Clarification of test

waveforms and methods has

been added throughout the

section. Category

designations have been added

to separate voltage and current

tests. Category designations

have been clarified, and

Category F was deleted.

No changes were made.

Icing Editorial and clarifications

changes only. No changes were made. No major changes were made.

Clarification of type of ice was

incorporated.

No changes were made.

Section 25: A new section was added to No significant changes were No significant changes were Added note that ESD connection

Electrostatic address device level made. made, except correcting point is not applicable to connector

Discharge susceptibility issues for ESD. typographical errors in the

figures. pins. Added expansion of type and

of the list of test points to be

considered. Address case of no

discharge.

Section 26: Section 26 was introduced in No changes were made. Categories A and B minor wording

Section 26: Section 26 was introduced in No changes were made. Categories A and B minor wording

Fire, DO-160E. changes, test method remained the

Flammability same. Category C: Flammability

Entire section removed and replaced

with FAA accepted methods

verbatim from FAA Fire Test

Handbook. Added configurations

exempt from testing. Added

definitions for “small parts

exemption”. Added user guide

A-11

06/22/2011 AC 21-16G

Appendix 1

Appendix 1

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F Changes from DO-160F to

DO-160G

addressing all three categories.

Appendix A Abandon the use of nameplate

marking for equipment

environmental qualification

category declaration.

A-12