Radar Vectors
Advisory Circular Cancelled Issued Nov 19, 2009 AIR-100 11 pages Copy saved Nov 18, 2026

AC 21-16F RTCA Document DO-160 versions D, E and F, “Environmental Conditions and Test Procedures for Airborne Equipment”

This document is cancelled. It may have been replaced. Check the official source before relying on it.

Official source ↗ Open PDF

U.S. Department of Transportation Federal Aviation Administration

Advisory Circular

Subject: RTCA Document DO-160 versions D, E and F, “Environmental Conditions and Test Procedures for Airborne Equipment”

Date: 11/19/09

Initiated by: AIR-100

AC No: 21-16F

1. What is the purpose of this Advisory Circular?

a. This advisory circular (AC) identifies RTCA Document No. (RTCA/DO)-160 versions D, E, and F, Environmental Conditions and Test Procedures for Airborne Equipment, dated July 27, 1997, December 20, 2005, and December 6, 2007, respectively, as containing acceptable environmental qualifications to show compliance with certain airworthiness requirements. We, the FAA, strongly encourage the use of RTCA/DO-160F for new articles.

b. Appendix 1 of this AC provides a summary of the changes from RTCA/DO-160C to RTCA/DO-160D, version D to E, and version E to F. The information in the table will assist you in determining if a particular version of RTCA/DO-160 is acceptable.

Note: When reference to RTCA/DO-160D is made in this AC, it includes Changes 1, 2, and 3, dated December 14, 2000, June 12, 2001, and December 5, 2002, respectively. c. This AC is not mandatory and does not constitute a regulation. This AC describes a means, but not the only means, to comply with airworthiness requirements.

2. To whom does this AC apply? This AC applies to manufacturers and installers that use RTCA/DO-160 for environmental qualifications of their airborne equipment. 3. Cancellation. This AC cancels AC 21-16E, RTCA Document DO-160E, Environmental Conditions and Test Procedures for Airborne Equipment, dated December 20, 2005. 4. What is RTCA/DO-160?

a. RTCA/DO-160 (or its precursor, RTCA/DO-138) has been used as a standard for environmental testing since 1958. It defines standard environmental test conditions (categories) and applicable test procedures for airborne equipment.

b. The tests in RTCA/DO-160 provide a laboratory means of demonstrating the performance characteristics of airborne equipment in environmental conditions that may be encountered in operation of the equipment in aircraft. It is not the intent of RTCA/DO-160 to be

used as a measure of service life of the airborne equipment subjected to these tests.

c. As the realities of equipment operation under actual environmental conditions are better understood and new needs arise within the aviation community, RTCA/DO-160 has been revised to address the emerging and improved test techniques. The categories that have been developed over time reflect a reasonably mature understanding as to the severity of the environmental stresses, the degrees of mitigation achievable in the design of an installation, and the robustness that must be designed into equipment in order to perform in the operating environment. 5. Related Documents.

a. Title 14 of the Code of Federal Regulations, (14 CFR) parts 21, 23, 25, 27, 29, 33 and

35 are relevant to this AC. b. AC 20-136, Protection of Aircraft Electrical/Electronic Systems Against the Indirect

Effects of Lightning.

c. AC 20-158, The Certification of Aircraft Electrical and Electronic Systems for

Operation in the High-Intensity Radiated Fields (HIRF) Environment.

d. AC 33.17-1, Fire Prevention. 6. Using RTCA/DO-160 for Technical Standard Orders (TSOs).

a. If you are an applicant seeking a TSO authorization for airborne equipment, you may request a deviation, in accordance with the requirements of 14 CFR § 21.609, to use the conditions and procedures in a different version of RTCA/DO-160 instead of the corresponding conditions and procedures specified in the applicable TSO. Although an applicant may request to use an earlier version, we recommend that you use RTCA/DO-160F.

b. The table in Appendix 1 of this AC provides sufficient data for an applicant to use as a comparison between RTCA/DO-160D, E, and F. The FAA has determined that versions D, E and F provide an equivalent level of safety when the applicable version is identified in the Environmental Qualification Form (EQF). If the installed electrical/electronic equipment must meet lightning requirements use RTCA/DO-160D or later per the latest revision of AC 20-136. However, if the installed equipment is expected to be subject to HIRF requirements in 14 CFR §§ 23.1308, 25.1317, 27.1317, or 29.1317, use RTCA/DO-160F. RTCA/DO-160E is also acceptable to meet the HIRF requirements for level B and C systems when using test levels defined in the appropriate regulations as discussed in AC 20-158.

c. If the version of RTCA/DO-160 specified in a TSO is version D or later, and an applicant wishes to use a version prior to RTCA/DO-160D, then the applicant must still apply for a deviation as discussed in paragraph 6a. However, instead of using Appendix 1 as referenced in paragraph 6b, the applicant must compare the specific procedure and category changes, section by section, between the two versions of RTCA/DO-160 and address the differences between the two test results when providing an equivalent level of safety.

d. When a new application is based on the design of an existing approved article, the applicant may ask to use environmental test data from the existing article’s environmental qualification, based on similarity between the two articles. This request must be fully supported with a detailed similarity assessment comparing the changes from the earlier approved article to the article in the new application. The ACO may accept the data if the similarity assessment clearly shows that the design changes will not adversely affect the environmental qualification. 7. Using RTCA/DO-160 for Installers.

a. If you are an applicant installing equipment, you may use RTCA/DO-160, any version, to support compliance with the appropriate airworthiness requirements. When possible, we recommend that you use RTCA/DO-160F as it provides the most clear and complete test procedures.

b. Use the EQF provided by the equipment manufacturer to compare against your specific installation requirements. The EQF provides information regarding which version of DO-160 was used, which environmental tests were conducted and the environmental category of the equipment being tested. If the EQF categories do not adequately address your installation, then you or the equipment manufacturer may need to re-qualify the equipment to meet the appropriate sections and category levels.

c. When installing equipment previously qualified to other environmental standards, such as Military Standard (MIL-STD) 810C, the equipment must comply with applicable airworthiness requirements. You may use DO-160F to do a comparison analysis to show that it provides an equivalent level of safety in the expected operating environment.

d. When a new application is based on the design of an existing approved article, the applicant may ask to use environmental test data from the existing article’s environmental qualification, based on similarity between the two articles. This request must be fully supported with a detailed similarity assessment comparing the changes from the earlier approved article to the article in the new application. The ACO may accept the data if the similarity assessment clearly shows that the design changes will not adversely affect the environmental qualification.

e. Some of the environmental conditions and test procedures contained in RTCA/DO-160 such as waterproofness, sand and dust, or salt fog, may not be applicable to your installation based on intended location of the equipment. You must determine which sections and categories are applicable to your specific project.

f. When the equipment installation is required to meet HIRF requirements in 14 CFR §§ 23.1308, 25.1317, 27.1317, or 29.1317 use RTCA/DO-160F. RTCA/DO-160E is also acceptable to meet the HIRF requirements for level B and C systems when using test levels defined in the appropriate regulations as discussed in AC 20-158. For additional guidance on HIRF refer to the latest revision of AC 20-158.

g. When the electrical/electronic equipment installations are required to meet lightning requirements use RTCA/DO-160D or later. For additional guidance on lightning refer to the latest revision of AC 20-136.

h. RTCA/DO-160, Section 26, Fire, Flammability, is not sufficient for 14 CFR parts 25 and 33. Fire and flammability guidance for 14 CFR part 25 is provided in 14 CFR part 25 Appendix F. For 14 CFR part 33, please refer to the latest revision of AC 33.17-1. 8. How To Get Related Documents.

a. Order copies of RTCA documents from RTCA, Inc, 1828 L Street, NW, Suite 805, Washington, DC 20036-4007, telephone (202) 833-9339, fax (202) 833-9434. You can also order copies online at http://www.rtca.org.

b. Order copies of 14 CFR parts from the Superintendent of Documents, Government Printing Office, P.O. Box 979050, St. Louis, MO, 63197. For general information, telephone (202) 512-1800 or fax (202) 512-2250. You can order copies from the Government Printing Office website at www.access.gpo.gov. Select “Access” then “Online Bookstore.” Select “Aviation,” then “Code of Federal Regulations.”

c. View a list of all Advisory Circulars on the FAA’s Aviation Safety Information Management System (AVSIMS) at www.faa.gov/regulations_policies/advisory_circulars/ or from the FAA website: www.faa.gov. Order copies of ACs from the U.S. Department of Transportation, Subsequent Distribution Office, M-30, Ardmore East Business Center, 3341 Q 75th Avenue, Landover, MD 20785.

Susan J. M. Cabler Assistant Manager, Aircraft Engineering Division

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-1

Appendix 1

Summary of changes between DO-160D, E, and F

RTCA/DO-160 will continue to be subject to revisions as needs arise in the aviation community. However, it is not always feasible

for an applicant to use the more current revision. The following table is a summary of the changes made from RTCA/DO-160C to D,

D to E, and E to F. Versions of RTCA/DO-160 prior to RTCA/DO-160D are also not included in this table. The information in the

table should help you determine if your new article should be subject to a particular version of RTCA/DO-160.

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

Section 1-Section 3:

Purpose and

Applicability,

Definitions of Terms,

and Conditions of Tests

Editorial and clarifications changes only.

Section 3: The requirement for

Section 3: The requirement for

cumulative testing of Temperature,

Altitude, Humidity, and Vibration was

removed, and clarification was added

with respect to the use of multiple test

articles.

Added section 2.9, Applicability of Test

Results and section 3.9, EUT

Configuration for Susceptibility Tests.

Section 4: Temperature

Section 4: Temperature

and Altitude

Section 4.3 Equipment Categories added

reference categories for in-flight loss of

cooling test.

Section 4.5 Temperature Test was

restructured to include sub-section 4.5.2

Operating Low Temperature.

Section 4.5.3 Ground Survival High

Temperature Test and Short Term

Section 4.5.3 Ground Survival High

Operating High Temperature Test

clarified soak time upon reaching short

time operating low and high temperature.

Section 4.5.5, In-Flight Loss of Cooling

Test in the note clarified cooling source

and power.

Section 5: Temperature

Variation

Section 5.3 Test Procedures was revised

Section 5.3 Test Procedures was revised

to provide provisions for collecting data

during a single cycle of test and reduced

data collection under certain test

conditions.

Section 5.2 Temperature Change Rates

added two temperature shock tests,

categories S1 and S2, and Sections 5.3.2

and 5.3.3 are the tests sections that

Section 5.2 Temperature Change Rates

accompany the newly added categories,

respectively.

Sections, 5.3.1h, 5.3.2h, and 5.3.3i,

changed the performance compliance

timing to be in the second, or last cycle.

1 Includes Changes 1, 2, and 3 to RTCA/DO-160D.

11/19/09 AC 21-16F

Appendix 1

A-2

DO-160D1 Changes from DO-160D1 to

Appendix 1

DO-160E Changes from DO-160E to

DO-160F

Humidity Editorial changes were made to eliminate

redundant description of the test

procedures. Velocity of air throughout

the exposure area changed from “Shall

not exceed 0.75 m/s” to “Between 0.5 and

1.7 m/s”. Alternative method was added to measure the water pH.

Section 6.3 was modified to allow a + 4

Section 6.3 was modified to allow a + 4

percent tolerance to the relative humidity

requirement.

In paragraphs 6.3.1, 6.3.2, and 6.3.3

changed step 2 to 38 degrees to agree

with corresponding figure.

Operational Shocks

and Crash Safety

Equipment category definitions were

added for fixed wing and helicopter

installations. Crash Safety levels were

identified for helicopters (20g) and

increased for fixed wing crash safety

levels (20g). Shock pulse was changed

from half sine to saw tooth. Half-sine

shock pulse curve changed to reflect saw-

tooth profile. Test levels were changed

from DO-160C based on empirical data.

Fixed wing and helicopter operational and

crash safety test requirements were made

the same.

Category definitions were revised for

clarification. Text description and

centrifuge definitions were revised in

section 7.3.3 and figure 7.3, respectively,

to reflect the correct setup direction for

acceleration load.

Vibration New section defining vibration

requirements for helicopters was added.

Random vibration levels were changed

by the addition of new curves. Tables

and figures were modified to support

changes in test levels.

Fixed Wing Zone 2 features two new test

curves. High Level Short Duration

Category Test was revised. Helicopter

endurance test times were reduced and

the unknown helicopter test procedure

was reconfigured (Category U).

Unknown helicopter test procedure

(Category U2) was added as an

alternative to revision D.

Performance test times were reduced

from 30 minutes to a minimum of 10

minutes. Robust test equipment operating,

not operating requirements were

standardized to have equipment not

operating during sinusoidal scans and

operating during the robust test portion of

the test, unless specified otherwise by the

applicable equipment specifications.

Explosion Proofness Fuel mixture calculation was corrected for

hexane explosive proofness test.

Atmospheric test pressure requirements

were clarified.

Minor changes were made in the

procedure to improve repeatability.

Environment definition and category

definitions were revised. Reference to

100/130 octane fuel was deleted from figure 9-4.

Waterproofness

Test step that verifies absence of water

penetration into test unit following test

was deleted because it was not consistent

with intent and purpose of test. The test

is intended to verify performance of unit

Minor improvements to pre-heat unit and

to reduce risk of thermal shock were

made.

Drip Rate was changed from 280

l/m2/hr to 140 l/m2/hr.

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-3

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

following exposure to this environment,

not to verify the unit’s ability to keep out

water.

Fluids Susceptibility

Table 11-1 eliminated reference to fire

extinguishants and add additional de-

icing fluid, propylene glycol. Aircraft

fire extinguishants are gaseous and do not

exist in liquid form under normal

conditions. De-icing fluid added to

reflect current industry practices.

Updated list of fluids and added

inspection.

No changes were made.

Sand and Dust Editorial and clarifications changes only.

Sand and dust were separated into two

categories. Update the mixtures to

current commercial available

characteristics.

Category definitions were revised for

clarification. Additional sand

concentrations were added. Size

distributions and sum of total percentages

to 100% were adjusted in Section 12.3.2.

Fungus Resistance Section 13.5.7 was revised to eliminate

48 hour period after removal from chamber before performance test.

Other causes of fungus other than nutrient

materials and personnel safety caution

were added.

Test failure criteria were clarified.

Magnesium sulfate was adjusted to align

with other ingredients.

Salt Fog Change functional test criteria.

Functional test may now be performed

following 48 hour dry-out period.

Title of section was changed from Salt

Spray to Salt Fog. Category T was added

for severe salt atmosphere.

Changed term Salt Spray to Salt Fog

throughout this section.

Magnetic Effect Text was added to clarify source of

referenced magnetic field.

Section 15.3 was modified to provide a

Section 15.3 was modified to provide a

more detailed test procedure than in

previous versions, including a

requirement to verify field uniformity if

the compass must be moved to change the

measurement distance to the EUT

(equipment under test). The new Figure

15-1 provides a test setup diagram and gives notes on proper performance of the

test.

A new Category Y was added for

measurements made immediately

adjacent to the unit under test.

Descriptions of each equipment category

were added to Section 15.1 Purpose of

Test along with discussion of how the test

results are used to determine how close

the EUT may be installed to a compass or

compass sensor. Text allowing the

measurements to be made with an

uncompensated compass or equivalent

magnetic sensor was also added.

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-4

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

Power Input

Change 2 to DO-160D, published June

12, 2001, revised Section 16, by including new tests, and modifications to existing

testing, to address the issues of AC

harmonic current content and variable

frequency AC power systems.

The entire section was re-ordered so that

all the AC tests were in one subsection

and all DC tests were in another

subsection, making Section 16 easier to

use and understand. DO-160E also

introduced some new tests, such as a DC

content test for AC powered equipment,

and a new subsection covering "Load

Equipment Influence on Aircraft

Electrical Power Systems."

More tests are required for both AC and

DC powered equipment. A 270V DC bus

generated from the A (WF) AC power

bus was added as Category D. Discrete

step test methods were defined for AM

and FM modulation on AC systems. AM

voltage modulation on AC buses was

increased. Double interrupt test methods

were added for DC equipment. Manual

reset was explicitly not permitted after

single and double power interrupts. The

dwell at 28V between the short and the

long dc voltage surge was removed. Loss

of phase testing was added for three

phase. A Power Factor test designation

was added for ac equipment. DC current

draw tests from ac equipment current

were added. In-rush and current

modulation test designations were added

for both ac and dc equipment. Tolerances

were added to most tests. Category H,

harmonic emissions, measurement

methods were updated.

Voltage Spike

Editorial changes were made to support

document consistency. Reference to "DC

only" condition was eliminated thereby

expanding applicability to both AC and

DC systems. Figures were modified to

accommodate the inclusion of AC power

systems. Reference to negative pulse

generation network was eliminated.

No significant changes were made.

Section 17.4 Test Procedures was

Section 17.4 Test Procedures was

modified to clarify application of positive

and negative transients over the specified

period of time. Test conditions were

clarified when multiple power pins are

present.

Audio Frequency

Conducted

Susceptibility-Power

Inputs

DO-160C referenced Figures 16-4 and

16-5 for DC ripple test requirements; these figures were moved to Section 18 as

Figures 18-2 and 18-3.

The equipment category designators A

and J were eliminated, and categories R

and K were added.

New test for 270V dc input differential

ripple to follow same curve as 28V

Category Z, but at 4 times the amplitude

was added. A common mode noise test

has been added for 270V Category Z

equipment. For test equipment that

generate a continuous linear frequency

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-5

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

sweep, the minimum (i.e., fastest) sweep

rate has been slowed to make swept

testing equivalent to stepped testing,

especially at resonances. An optional DC

blocking network is added to the test

setup figures to prevent damage to the

signal source.

Induced Signal

Susceptibility

Category C was added to include test

levels that are appropriate for installations

with long wire runs or minimum wire

separation. The test levels for magnetic

and electric fields induced into wiring

were increased.

A second equipment category designator

was added to indicate the AC power

system operating frequency (Constant,

Narrow Variable, or Wide Variable). The

frequency scan rate was changed to 30

steps per decade, with a 10-second dwell

time at each frequency.

Clarification to existing formula used to

calculate test frequencies was made.

Radio Frequency

Susceptibility (Radiated

and Conducted)

The revisions to Section 20, in DO-160D

Change No.1, published December 2000,

include a new, Mode-Tuned,

Reverberation Chamber Radiated RF

Susceptibility test method. New

categories (test levels) were also added to

Section 20, including Category L, which

requires Radiated RF Susceptibility

testing (pulsed) as high as 7200

volts/meter.

An alternate procedure was added for

mode-stirred radiated susceptibility tests.

Section 20, including Category L, which

The mode-stirred procedure was accepted

as an alternate that may require lower-

power amplifiers.

A section providing guidance and caution

related to RF power amplifier harmonics

and their potential to affect the test results

was added, along with a revision that

allows the use of an oscilloscope to

measure Conducted Susceptibility test

levels. The Mode-Tuned test method for

Radiated Susceptibility was modified to

allow for the option of using the received

power on the monitor antenna to

determine the test level, as opposed the E-

field readings from a 3-axis sensor.

Flexibility in the number of tuner steps

was also added, giving the user the choice

of increasing the number of steps based

on the need for greater field uniformity or

a higher test level, or decreasing the

number of tuner steps to decrease the test

time.

Test categories were reduced and

“alternative” modulations for Category R

were eliminated. There is now only one

test method for conducted susceptibility.

Clarification has been added regarding

the requirement to expose all apertures

and openings of the EUT in anechoic

chamber method. RTCA/DO-160F added

requirements to test several additional

dwell frequencies where the image

frequencies for n =2 through 10. 160F

removed the permissive language

associated with these tests. It used to be

“should” but 160F now uses “shall”.

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-6

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

Emission of Radio

Frequency Energy

Change Category Z requirements to

reflect need for additional scrutiny in the

VHF COM NAV and GPS frequencies.

All of the figures were cleaned up and

made easier to read. The Radiated

Emissions limits for Categories M and H

were modified slightly so that the notches

that occur in various frequency ranges

now have sloped bottoms to match the

rest of the limit. The frequency range of

the first notch has also been changed for a

more precise match with the

communications/navigation frequency

range that the notch protects.

The conducted emissions frequency range

has been broadened to 150 kHz - 152

MHz, and the Radiated Emissions test

frequency range has been narrowed to

100 MHz - 6 GHz. A new procedure for radiated emissions measurements in a

reverberation chamber was added. In the

anechoic chamber method, clarification

has been added regarding the requirement

to expose all apertures and openings of

the EUT. A new limit category has been

added, Category P, to provide added

protection for certain receivers by use of

even deeper notches than previously used.

Lightning Induced

Transient Susceptibility

DO-160D Change No. 3, published

December 2002, added additional

waveform sets, cable bundle test levels,

and the procedures for performing

indirect lightning multiple stroke and

multiple burst tests using the existing

defined test waveforms. The category

designations were modified to allow users

to designate categories that indicated that

these additional tests had been performed.

New Waveform Set designators, G

through K, were added to cover the

Multiple Burst and Multiple Stroke tests.

Another significant addition to Change 3

was setup information on performing pin

injection tests with power applied.

Several different setup diagrams were

added to assist users in performing these

tests properly. Improperly connecting the

lightning generator to a pin with power

applied could result in insufficient stress

on the pin.

The DO-160E cable bundle test section

was modified to include a new section

providing guidance for performing cable

bundle tests on bundles that normally

contain shields, with the shields removed.

This guidance allowed testing of a cable

bundle at test levels currently defined in

DO-160, but intended to demonstrate

compliance to aircraft installation threats

that are higher than these standardized

levels. It explicitly stated that the test

generator used for cable bundle testing

does not need to be capable of producing

the voltage or current limit level,

provided that the current or voltage test

level can be achieved on the cable under

test.

Section 22 was restructured with

Section 22 was restructured with

additional test requirements moved from

notes under figures to the main body of

the document, and paragraphs were

numbered to provide easy reference to the

requirements contained in each

paragraph. In the waveform set tables

and the test level tables, both the voltage

and the current waveform number are

now shown to eliminate any ambiguities

with how waveforms are related to each

other.

This section was modified to clarify when

a test was successfully completed and

when, in the case of reaching a limiting

level before a test level, another

waveform test was needed. The cable

bundle section now contains a path to

follow for every waveform set and

criteria for acceptable and unacceptable

test limit waveforms that leads the user to

successful test completion regardless of

the configuration of the cable under test.

11/19/09 AC 21-16F

Appendix 1

Appendix 1

A-7

DO-160D1 Changes from DO-160D1 to

DO-160E Changes from DO-160E to

DO-160F

Lightning Direct

Effects

Additional procedure with associated

electrode was provided for producing

flashover when flashover is not produced

during the normal procedure and it is

desired that flashovers occur.

No significant changes were made.

Clarification of test waveforms and

methods has been added throughout the

section. Category designations have been

added to separate voltage and current

tests. Category designations have been

clarified, and Category F has been

deleted.

Icing Editorial and clarifications changes only.

No changes were made.

No major changes were made.

Clarification of type of ice was

incorporated.

Electrostatic Discharge A new section was added to address

device level susceptibility issues for ESD. No significant changes were made.

No significant changes were made, except

correcting typographical errors in the

figures.

Fire, Flammability

Section 26 was introduced in DO-160E. No changes were made.