AC 150/5340-26C Maintenance of Airport Visual Aid Facilities
This AC provides guidance and specifications for the Maintenance of airport Visual Aid Facilities. See also Awareness of and Guidance on Maintaining Airport-Owned Approach Lighting Systems and Visual (Including Lighted Navigational) Aids (9/13/2023).
Department of Transportation seal
U.S. Department of Transportation
Federal Aviation Administration
Advisory Circular
Subject: Maintenance of Airport Visual Aid Facilities
Date: 6/20/2014 Initiated by: AAS-100
AC No: 150/5340-26C Change:
1. Purpose. This advisory circular (AC) provides recommended guidelines for maintenance of airport visual aid facilities.
2. Applicability. The Federal Aviation Administration (FAA) recommends the guidance and specifications in this AC for the Maintenance of airport Visual Aid Facilities. In general, use of this AC is not mandatory. However, use of this AC is mandatory for all projects funded with federal grant monies through the Airport Improvement Program (AIP) and with revenue from the Passenger Facility Charges (PFC) Program. See Grant Assistance No. 34, Policies, Standards, and Specifications, and PFC Assurance No. 9, Standards and Specifications.
3. Cancellation. This AC cancels AC 150/5340-26B, Maintenance of Airport Visual Aid Facilities, dated September 30, 2009.
4. Principal Changes. General grammatical and format changes to break up large sections and to facilitate easier reading.
a. Paragraph 2.0 has an added section to better introduce the concept of safety.
b. Paragraph 2.2 – a new section is added to be in better alignment with the personnel safety
requirements in National Fire Protection Association (NFPA) 70E, Standard for Electrical Safety in the Workplace.
c. Paragraph 2.4.1.1 is added for arc flash protection description.
d. Figure 2-1 is added to show an example of an arc flash warning label.
e. Paragraph 3.2.1 is added to describe maintenance log requirements for PAPI, VASI, and
ODALS.
f. Paragraph 3.7 is added to describe what to do when visual aids are implicated in an
aircraft accident. Procedures are also furnished for actions to be taken when a visual aid that was previously NOTAM is restored to service.
g. Paragraph 5.3.4 is expanded to add requirements for bolt torque and explain one-time
bolt use for in-pavement light fixtures.
h. Paragraph 5.11 – removed “hazard beacons” and added note.
Figure 2-1 · page 4Picture of the page from the copy saved here
i. Paragraph 5.15, Omnidirectional Approach Lighting System (ODALS), is added.
j. Appendix B is added: Maintenance Log Preparation Guide.
Michael O'Donnell Director of Airport Safety and Standards
ii
iii
Table of Contents
Chapter 1. Introduction … 1
1.0 General … 1 1.1 Scope … 1 1.2 Applicable Documents … 2
Chapter 2. Safety … 5
2.0 General … 5 2.1 Common Causes of Accidents … 5 2.2 Safety Requirements … 6 2.3 Safety Procedures and Guidelines … 8 2.4 Electrical Hazards of Series Lighting Circuits … 8 2.5 Safety Practices … 10 2.6 Safety Boards … 13 2.7 Safety Checklist … 14 2.8 Safety Equipment in Vehicles … 14 2.9 Electric Shock … 14 2.10 Safety Training … 15 2.11 Safety Warning Signs/Danger Tags … 15 2.12 Grounding and Bonding … 17 2.13 Confined Spaces … 17 2.14 Lightning … 17 2.15 Toxic Agents … 18 2.16 Fire Extinguishers … 18 2.17 First Aid … 21
Chapter 3. Maintenance Management … 23
3.0 Maintenance Philosophy … 23 3.1 Maintenance Schedule … 23 3.2 Maintenance Records … 24 3.3 Preventive Maintenance Program … 24 3.4 Record Retention … 26 3.5 Reference Library … 26 3.6 Spare Part Provisioning … 27 3.7 When Lighted Navigational Aids are Identified as Suspect in an Aircraft Accident. .29
Chapter 4. Test Equipment … 31
4.0 Introduction … 31 4.1 Types of Equipment and Usage … 31
Chapter 5. Preventive Maintenance … 39
5.0 General … 39 5.1 Airport Lighting Vault … 39 5.2 Constant Current Regulators (CCRs) … 47 5.3 Light Fixture and Base Maintenance … 51 5.4 Illuminated Runway and Taxiway Guidance Signs … 68
iv
5.5 Rotating Beacons … 68 5.6 Lighted Wind Cone Assemblies … 72 5.7 Precision Approach Path Indicator (PAPI) System … 74 5.8 Visual Approach Slope Indicator (VASI) … 78 5.9 Runway End Identifier Lights (REILs) … 81 5.10 Medium Approach Lighting System (MALS, MALSF, MALSR) … 85 5.11 Obstruction Lights … 88 5.12 Airport Lighting Control and Monitoring Systems (ALCMS) … 91 5.13 Runway Status Lights (RWSL) … 93 5.14 Standby and Emergency Power Systems … 95 5.15 Omnidirectional Approach Lighting System (ODALS) … 102
Chapter 6. Troubleshooting Procedures for Series Lighting Circuits … 107
6.0 Initial Fault Investigation – Safety … 107 6.1 Locating Ground Faults in the Field … 109 6.2 Locating Open Circuit Faults … 110 6.3 Interconnected Circuit Faults … 111 6.4 Intentional Ground Test … 112 6.5 Grounded Output Test for Locating Open Circuits … 114 6.6 Using Heat Sensing Equipment to Locate Ground Faults … 115 6.7 Using Cable Fault Locating Equipment to Locate Ground Faults … 115
Appendix A. Standards and Tolerances … 127
Appendix B. Maintenance Log Preparation Guide … 137
List of Figures
Figure 2-1. An Arc Flash Warning sign … 13 Figure 2-2. Example of a “Danger – High Voltage” sign … 15 Figure 2-3. Examples of Danger Tags … 16 Figure 5-1. Sample Insulation Resistance Record … 43 Figure 5-2. Cleaning Runway Centerline and Touchdown Zone Lights … 66 Figure 5-3. PAPI Configuration … 76 Figure 5-4. REIL Layout … 83 Figure 5-5. REIL Aiming … 84 Figure 5-6. MALSR Configuration … 86 Figure 5-7. Light Fixtures Inoperative Requiring THL Shutdown … 94 Figure 6-1. Typical Series Lighting Circuit … 116 Figure 6-2. Typical Ground Faults … 117 Figure 6-3. Locating Ground Faults with the VOM … 118 Figure 6-4. Alternative Method of Finding Ground Fault Using VOM or Insulation Resistance
Tester … 119 Figure 6-5. Locating Open Circuit Faults … 120 Figure 6-6. Single Load-to-Load Fault … 121
v
Figure 6-7. Two Load-to-Load Shorts … 122 Figure 6-8. Intentional Ground Test … 123 Figure 6-9. Intentional Ground Preventive Maintenance Tool … 124 Figure 6-10. Grounded Output Test … 125 Figure 6-11. Dangerous Isolation Transformer/Circuit Ground Faults … 126
List of Tables
Figure 2-2 · page 4Picture of the page from the copy saved here
Table 5-1. Preventive Maintenance Inspection Schedule for Airport Lighting Vaults … 47 Table 5-2. 3-Step CCR Output Tolerances … 50 Table 5-3. 5-Step CCR Output Tolerances … 51 Table 5-4. Preventive Maintenance Inspection Schedule for Constant Current Regulators … 51 Table 5-5. Preventive Maintenance Inspection Schedule for Runway and Taxiway Elevated
Edge Lights … 59 Table 5-6. Preventive Maintenance Schedule for In-pavement Runway and Taxiway Lighting 65 Table 5-7. Preventive Maintenance Schedule for Rotating Beacons … 72 Table 5-8. Preventive Maintenance Schedule for Lighted Wind Cones … 74 Table 5-9. Preventive Maintenance Schedule for PAPI (Precision Approach Path Indicator) ... 77 Table 5-10. Preventive Maintenance Schedule for VASI (Visual Approach Slope Indicator) ... 81 Table 5-11. Preventive Maintenance Schedule for REIL (Runway End Identifier Lights) … 85 Table 5-12. Preventive Maintenance Schedule for MALSR (Medium Intensity Approach Light
System with Runway Alignment Lights) … 87 Table 5-13. Preventive Maintenance Inspection Schedule for Hazard Beacons and Obstruction
Lights … 91 Table 5-14. Quarterly and Annual Preventive Maintenance Checklist for Standby Generator Sets
… 101 Table 5-15. Preventive Maintenance Schedule for ODALS (Omni directional Approach Light
System) … 106
vi
Intentionally Left Blank
Chapter 1. Introduction.
1.0 General.
This Advisory Circular (AC) provides guidance for the recommended minimum maintenance practices to be used for the maintenance of airport visual aid facilities. Although this AC provides the minimum requirements for establishing a maintenance program, due to the varying complexities of individual airports and the visual aids facilities provided, the program must be tailored to suit each airport’s particular needs. Use this AC with the information available in manufacturer’s instruction books, equipment manuals, handbooks and other ACs.
Chapter 1. Introduction. › 1.1 Scope.
Because the function of airport visual aid facilities is to assist in the safe and efficient movement of aircraft during landing, takeoff and taxiing maneuvers, it is essential that a high degree of operating reliability be maintained. To achieve this, an effective preventative maintenance program must be established and maintained. This AC provides suggestions about establishing a program but, due to the varying complexities of airports and the visual aids facilities provided, the program must be tailored to suit each airport’s particular needs.
Because corrective and preventive maintenance procedures for specific equipment are usually covered in instruction manuals supplied with the equipment, this AC will address maintenance topics of a more general nature.
1.1 Scope.
This AC provides system maintenance information for establishing a preventive maintenance program for airport visual aid facilities. The information provided is for the following systems:
• Airport lighting vault and series lighting circuits • Constant current regulators • Runway and taxiway elevated edge lighting systems • Runway and taxiway in-pavement lighting systems • Runway guard lights and stop bar lights • Illuminated runway and taxiway signs • Rotating beacons • Lighted wind cone assemblies • Precision Approach Path Indicator (PAPI) system • Visual Approach Slope Indicator (VASI) • Runway End Identifier Lights (REIL) and Omni directional Approach Light System (ODALS) • Medium Intensity Approach Light System (MALS, MALSF, MALSR) • Airfield Lighting Control and Monitoring system (ALCMS) • Runway Status Lights (RWSL) • Obstruction lights • Control systems • Standby power engine generator systems
Chapter 1. Introduction. › 1.2 Applicable Documents.
In addition to equipment topics, this AC also recommends safety practices and troubleshooting procedures for airport series lighting circuits.
1.2 Applicable Documents.
1.2.1 National Fire Protection Association (NFPA).
• NFPA 10, Standard for Portable fire Extinguishers
• NFPA 70E, Standard for Electrical Safety in the Workplace
NFPA documents may be obtained (not free of charge) at: www.nfpa.org/catalog/category.asp?category_name=NFPA+70E
1.2.2 Occupational Safety and Health Administration (OSHA).
• General Industry Safety-Related Work Practices – 29 CFR 1910
OSHA documents may be obtained at: https://www.osha.gov/pls/oshaweb/owastand.display_standard_group?p_toc_level=1&p_part_nu mber=1910
1.2.3 American Society for Testing and Materials (ASTM).
• ASTM D120, Specification for Insulated Rubber Gloves
ASTM specifications may be obtained via standard mail from:
American Society for Testing and Materials 1916 Race Street Philadelphia, PA 19103.
Specifications may also be purchased and downloaded (charges may apply) from the internet at: webstore.ansi.org/SdoInfo.aspx?sdoid=41&Acro=ASTM&DpName=ASTM%20International&s ource=googe&keyword=astm&gclid=CPuey-Sy1boCFe5cMgodMi0AIA
1.2.4 Federal Aviation Administration (FAA) Advisory Circulars (AC).
• AC 150/5210-5, Painting, Marking, and Lighting of Vehicles Used on an Airport
• AC 150/5210-20, Ground Vehicle Operations on Airports
• AC 150/5340-30, Design and Installation Details for Airport Visual Aids
• AC 150/5345-46, Specification for Runway and Taxiway Light Fixtures
FAA ACs may be downloaded at: www.faa.gov/airports/resources/advisory_circulars/
1.2.5 FAA Engineering Briefs (EB).
• FAA EB 83, In-pavement Light Fixture Bolts
FAA EBs may be downloaded at: www.faa.gov/airports/engineering/engineering_briefs/
1.2.6 Federal Aviation Administration (FAA) Joint Orders (JO).
• JO 7930.2, Notices to Airmen (NOTAM)
May be obtained at: http://www.faa.gov/documentLibrary/media/Order/NTM.pdf
Intentionally Left Blank
Chapter 2. Safety. › 2.1 Common Causes of Accidents.
Chapter 2. Safety.
2.0 General.
This chapter provides information that will aid airport owners/operators in establishing an effective safety program. Safety is the responsibility of everyone and must be practiced in every maintenance activity that is performed. Any additional local operational procedures and OSHA requirements should also be followed. The safety program established at each airport should include preventive safety precautions used when servicing the equipment and first-aid procedures for use in the event of an injury.
We are all surrounded by various hazards every day such as the careless driver using a cell phone that we see on our way to work. Safety is everyone’s responsibility and our own responsibility. We cannot delegate our safety responsibilities to others. It is our responsibility to set the safety example for others. Safe work practices is a learned attitude and skill we should be passing on to our fellow workers and our family.
Safety is no accident. Know and comply with your company’s safety program and lockout/tagout procedure. Use and store personal protective equipment (PPE) properly. Verify that your test equipment functions properly. Become familiar and knowledgeable with National Fire Protection Association (NFPA) 70E, Standard for Electrical Safety in the Workplace. Should a conflict between your local safety plan and this document occur, we recommend adherence to the stricter (safer) requirement.
THINK SAFETY FIRST!
2.1 Common Causes of Accidents.
Some common causes of accidents are listed below:
a. Working on equipment without adequate coordination with equipment users.
b. Working on equipment without sufficient training or experience.
c. Failure to follow instructions in equipment manuals.
d. Failure to follow safety precautions.
e. Failure to properly lock and tag out equipment.
f. Using unsafe equipment.
g. Becoming lax due to working in a familiar environment.
h. Poor housekeeping of work areas.
i. Working in a hurried manner.
Chapter 2. Safety. › 2.2 Safety Requirements.
The number one cause of accidents is working in a hurried manner. It is often the main contributing factor in failing to follow proper safety guidelines in all the other causes outlined in the list above. The perception that there is not enough time to take proper safety precautions or think through the proper procedures has a high potential for causing an accident. When in emergency repair situations, maintenance personnel must be careful to follow proper safety procedures to avoid the possibility of injury or death.
2.2 Safety Requirements.
Only a qualified person, per the definition in NFPA 70E, performs maintenance work. The qualified person must possess the requisite technical skills and be trained to recognize and avoid electrical hazards. The qualified person must also be trained in the proper procedures for operations in an aircraft operation area (AOA). A person may be considered qualified for certain tasks and not qualified for others.
2.2.1 Qualified Person.
A qualified person must, at a minimum, be additionally trained to:
• Distinguish exposed live parts from other parts.
• Determine nominal voltage of exposed parts.
• Determine the approach distances in NFPA 70E; Table 130.2(C).
• Possess the decision-making skills necessary to determine the degree and extent of hazard, PPE required and planning to safely perform the job.
2.2.2 Hazard/Risk Evaluation.
Perform a Hazard/Risk evaluation of the task to be accomplished. For an example of a Hazard/Risk procedure, refer to NFPA 70E, Annex F.
When performing repetitive tasks we tend to take safety for granted. Do not let familiarity with the task provide a false sense of security. A task performed 100 times unsafely without an injury is still unsafe.
2.2.3 Job Set-up.
Before starting each task, review the following basic items:
a. Hazards associated with the work.
b. Safe work procedures and any special precautions.
c. Energy source controls.
d. PPE requirements.
2.2.4 Electrically Safe Work Condition.
Energized parts or components that an employee may be exposed to must be put into an electrically safe work condition before an employee works on or near them. Electrical components must be considered to be energized until the source(s) of energy is (are) removed, at which time they must be de-energized. In addition, remove all other sources of energy or stored energy – capacitors, pneumatic, steam, chemical, springs, gravity, jet blast, etc.
a. Determine all sources of energy to the equipment.
b. Turn off the equipment using proper controls; open the disconnecting means for each
electrical source.
c. When possible, visually verify all blades of the disconnecting device are fully open
and/or draw-out type circuit breakers are withdrawn to the fully open position.
d. Verify all other energy sources have been identified and turned off, removed, blocked or
secured as required to safely and properly control the specific energy source.
e. Apply lockout/tagout devices per documented and established policy.
f. Use an adequately rated volt meter to test phase-to-phase and phase-to-ground for
voltage. Before and after the test, verify proper operation of the test equipment.
g. Where the possibility of induced voltages or stored electrical energy exists, ground the
phase conductors or circuit parts. If components could become reenergized use grounds that can withstand fault currents.
h. Only when the previous seven steps (2.2.4a through 2.2.4g) are successfully completed,
is it possible to create an Electrically Safe Work Condition.
2.2.5 Electrically Unsafe Work Condition.
An electrically unsafe work condition is defined as “working on or near live parts of 50 volts or more.” The word, “near” is defined as “within the limited approach boundary provided by NFPA 70E, Table 130.4(C) and Table 130.4(C)(b).” To perform work on or near live parts of 50 volts or more, the following steps must be accomplished:
a. Justification – Demonstrate that de-energizing introduces additional or increased hazards
or is not feasible due to equipment design or operational limitations. (see NFPA 70E, Section 130.2)
b. Complete an energized work permit that authorizes work on energized equipment.
c. Perform an electrical hazard analysis consisting of:
1. A shock hazard analysis to determine the voltage(s) to which personnel will be exposed, boundary requirements and the personal protective equipment (PPE) necessary to minimize the possibility of electric shock to personnel.
Chapter 2. Safety. › 2.4 Electrical Hazards of Series Lighting Circuits.
2. A flash hazard analysis must be completed to protect personnel from the possibility of being injured by an arc flash. The analysis determines the flash protection boundary and the PPE that personnel within the flash protection boundary must use.
d. Implement the requirements of the shock and flash hazard analysis prior to starting any
work.
e. Complete the work safely and return the system to safe operating status.
f. Close out the energized equipment work permit.
2.3 Safety Procedures and Guidelines.
Most airport visual aid equipment is exposed to weather and may develop electrical shock hazards through damage from lightning or electrical cable insulation deterioration from exposure. Begin maintenance procedures only after a visual inspection is made for possible hazards. Due to the hazards associated with lightning, lighted navigational aids should not be serviced during periods of local thunderstorm activity. Each airport should develop and implement procedures to be followed in the event of an accident. Precious seconds are saved rendering medical assistance to injured personnel when action plans are already in place. Rehearse and review action plans regularly.
2.4 Electrical Hazards of Series Lighting Circuits.
Airport lighting circuits are very dangerous. This is especially true for maintenance personnel with little or no experience working on constant current series circuits. Airport lighting circuits can operate at potentials of several thousand volts depending on the size of the regulator driving the circuit and the load.
2.4.1 Basic Rules.
There are three basic rules to remember when working on and around airport lighting circuits:
a. ALWAYS assume that the circuit is energized until you have proven otherwise.
ALWAYS check for current before disconnecting the series circuit connector, removing the S1 cutout, or opening the primary series circuit by any other means. Make it a required practice to check the circuit with an ammeter prior to breaking the connection – NO EXCEPTIONS. Never attempt to measure voltage in a series lighting circuit using ordinary volt meters. An inductive voltage measuring device (sometimes referred to as a “ticker”) such as is described in Chapter 4 may be used to detect the presence of induced voltage on a series lighting cable after checking for the presence of current. Always use a true RMS clamp-on type ammeter to verify if the circuit is energized. ALWAYS check
the operation of the test equipment on a known live circuit before and after measurements are taken.
b. NEVER under any circumstances open or break a live airfield series circuit. The voltage
generated in the circuit can reach levels many times normal before the regulator’s open circuit protection can shut it down. As long as a current flow can be maintained, even if it is through you, the regulator will continue to operate. This is one of the reasons that series circuits can be so hazardous to work around - there is no personnel protection provided such as might be found on parallel interior wiring.
c. NEVER enter a manhole with energized conductors and never handle cables or
transformers in light bases while there is current present. Cables or connectors can have cracked insulation where it is not visible or may be deteriorated and fall apart, exposing you to live circuit conductors.
2.4.2 Induced Voltages.
Series circuits are typically run from the lighting vault in duct banks where the wires are lying parallel to each other in close proximity. Voltages may be induced in an otherwise un-energized conductor and may be a hazard when troubleshooting and testing. Circuits that have a load that varies due to flashing action of runway guard lights or REIL strobes are particularly prone to induce voltages in other conductors due to the pulsing characteristics of the voltage and current in these circuits. Always remember that there may be a possibility of an induced voltage in any conductor. Never work on or in close proximity to live circuits within any duct or manhole.
2.4.3 Re-lamping.
The most common lighting maintenance task on the airfield is re-lamping of incandescent runway and taxiway lighting fixtures.
Note: See paragraph 5.3.2 for information about light emitting diode (LED) light fixtures.
Depending on the type of light fixture, this may be accomplished in the field or, in the case of most in-pavement lights, the entire light fixture is removed, replaced, and brought to the maintenance shop for refurbishing. The greatest unseen danger to you is re-lamping or removing the fixture with the circuit energized. This has always been a common practice by airport electricians for convenience and the dangers are often overlooked. There are two primary hazards associated with this practice:
a. The first hazard occurs when there is a short circuit between the isolation transformer
primary and secondary windings. Remember that isolation transformers are not designed for personnel protection. They are designed to isolate the secondary winding from the primary circuit to allow continued operation with a lamp burned out. A transformer with a primary to secondary short may not cause a circuit malfunction and could remain unnoticed during normal operation.
A short from the isolation transformer primary to secondary winding exposes you to the full voltage present on the primary circuit and can be especially dangerous if another
short is present on the primary circuit. When that happens, you can become the path to ground for the full primary current, a circumstance that is almost always fatal. This condition is especially dangerous when working with inset lights and removing them from the light base while the circuit is still energized. As soon as the light fixture is unbolted and lifted from the light base, you might become the path to ground. The FAA has tried to eliminate this hazard by recommending the attachment of a ground wire from the bottom of the light fixture to a grounding lug on the inside of the light base. Remember, you cannot know if the light fixture grounding wire is truly connected until you remove the fixture, at which time it is too late.
Chapter 2. Safety. › 2.5 Safety Practices.
b. The second hazard encountered when re-lamping an energized light fixture is from the
open circuit voltage present at the secondary of the isolation transformer. The open circuit voltage present on the secondary of the isolation transformer is proportional to the size of the transformer. For example, the open-circuit secondary voltage on a 300 watt transformer is approximately 110 volts. Moreover, depending on the materials used in the design of the isolation transformer and the type of regulator powering the circuit, high voltages can be generated. The larger the wattage of the isolation transformer, the higher the open circuit voltage; as much as 200 volts may be present in some circumstances. Therefore, we recommend that you perform re-lamping of the series lighting circuits with the circuits de-energized, especially during the re-lamping of fixtures with exposed contacts.
c. A final hazard that is present when re-lamping any type of fixture, whether in the field or
at the maintenance shop, is the danger of cuts from broken lamps. Many times when an airfield lamp fails, the glass envelope becomes cracked or brittle and can break during the removal process. Always wear leather gloves when removing lamps to prevent your hands from being cut in the event that a lamp shatters.
2.5 Safety Practices.
When you perform maintenance on airport visual aids, use the following safety practices:
a. Ensure that all maintenance workers are trained and familiar with electrical safety.
b. Strictly observe all safety rules.
c. Ensure that all test equipment is listed by a third party testing laboratory and properly
rated for the voltage under test and the intended application.
d. Prior to beginning any maintenance work on airport lighting circuits, coordinate the work
schedule with the air traffic control tower, facility manager, or airport operations personnel. Make sure circuits will not be energized during maintenance by observing strict lock-out tag-out procedures for the equipment and obtain authorization for local control if equipment is normally operated via remote control.
e. Where maintenance is to be conducted on a high-voltage circuit, assign at least two
electricians, with at least one having a thorough knowledge of the layout of all airport high-voltage circuits.
f. Because performing maintenance on many airport visual aids requires workers to traverse
the active airfield, all workers must be fully knowledgeable of air traffic control and radio communication procedures. Workers must also be familiar with airport runway and taxiway layouts to avoid the possibility of runway incursions. All air traffic control instructions must be read back to the controller and, if the worker has any question regarding the instructions of the controller, the worker must ask the controller to repeat the message. All vehicles operated within the aircraft operations area (AOA) must be properly marked and lighted per FAA AC 150/5210-5, Painting, Marking and Lighting of Vehicles Used on an Airport.
If you are designated as an observer electrician, your duties include:
• Keeping other personnel not involved in the work clear of the equipment.
• Being familiar with power disconnects and immediately disconnecting the power source in case of emergency.
• Being qualified in first-aid and prepared to render emergency care if necessary. You should keep in mind that prevention of an electrical accident is of primary importance though first-aid treatment is available.
• Observing the work being done to detect and prevent unsafe practices.
2.5.1 Personal Safety Precautions.
Every electrician should use the following safety precautions:
a. Know the location of main power disconnect devices.
b. Know how to summon medical aid.
c. De-energize circuits by removing the proper fuses using insulated fuse pullers or by
turning off and locking out circuit breakers or other disconnecting means. Consult circuit diagrams to identify all fuses, breakers or disconnects involved. Remember that removal of a fuse does not remove the voltage from the “hot” fuse clip. Discharge all capacitors.
d. Do not depend on interlocks to remove power or on indicating lights to signal that power
is off. Verify that power is off by using a voltmeter and/or ammeter on the component after opening the power switch. Verify operation of voltmeter (or ammeter) on known live circuit before and after measurements are taken.
e. Insulate your feet by standing on a dry rubber mat. Remember, however, that any contact
with the grounded equipment cabinet could nullify this protection.
f. Stay clear of terminals, leads, or components that carry voltages of any magnitude. Also,
avoid contact with components that are grounded, including the equipment cabinet frame.
g. Shut down and de-energize the equipment when it is necessary to reach into the
equipment in locations where rapid and direct withdrawal of the hand is not possible. In any case, only one hand should be exposed, with the other hand kept away from contact with voltages or ground.
h. Be certain that there is no power applied to a circuit when making a continuity or
resistance check (the meter will be damaged and you could be injured).
i. Ground test equipment to the equipment under test unless otherwise specified in
instruction manuals.
j. Place a warning sign, such as “DANGER - DO NOT USE OR OPERATE,” at the main
switch or circuit breaker, and provide a lockout for the circuit on which you will be working. Follow direction of local facility lock-out tag-out procedures manual.
k. Do not wear jewelry, wristwatches, or rings while working with electrical equipment.
l. Keep clothing, hands, and feet dry if at all possible.
m. Use the correct tool (screwdriver, alignment tool, etc.) for doing the job.
n. Never use toxic or flammable solvents for cleaning purposes.
o. Where air pressure is required for cleaning, use a low-pressure (30 psi or less) air source.
Eye protection (goggles or face mask) is necessary when using compressed air for cleaning.
p. Do not take anything for granted when working with inexperienced help.
2.5.1.1 Arc Flash Protection. Understanding the Arc Flash Warning Labels
a. Each piece of equipment operating at 50 volts or more and not de-energized while work
is being performed, must be evaluated for arc flash hazard and shock protection. This evaluation will determine the boundaries (i.e. prohibited, limited, restricted, etc.) of the arc flash and shock hazards. The evaluation will inform employees of what PPE must be worn.
b. When the evaluation is complete, an arc flash hazard warning label (see Figure 2-1) must
be affixed to the equipment and be conspicuous to employees who may work on the energized equipment.
Chapter 2. Safety. › 2.6 Safety Boards.
Figure 2-1. An Arc Flash Warning sign
2.6 Safety Boards.
Locate a plywood board for posting safety procedures and a pegboard for mounting safety equipment in the airport lighting vault, switchgear rooms, engine generator rooms, and other appropriate locations. In addition, provide a telephone for emergency use as well as regular communications use. Recommended safety procedures and safety items to be included on or adjacent to safety boards are as follows:
a. Accident and fire procedures. b. Emergency telephone numbers, such as doctor, hospital, rescue squad, fire department,
airport operations, police and Air Traffic Control Tower (ATCT). c. Resuscitation instructions. d. Resuscitation equipment (Resuscitube or equivalent). e. First-aid kit. f. High-voltage disconnect (hot) stick. g. Non-conductive body rescue hook. h. Rubber gloves rated for maximum voltage present with leather gloves and protective
storage bag. i. Insulated fuse puller. j. Non-metallic flashlight k. Grounding stick. l. Safety posters and bulletins. m. Portable non-conductive warning signs with non-conductive hangers. n. Fire extinguisher of proper type rating for electrical fires. o. Emergency eyewash station if not provided elsewhere in building. p. Automatic External Defibrillator (may require certified personnel)
Chapter 2. Safety. › 2.9 Electric Shock.
2.6.1 Safety Board Inspection.
Inspect the equipment located on the safety board as indicated below:
a. Test rubber gloves in accordance with ASTM D120, Specification for Insulated Rubber
Gloves.
ASTM specifications may be obtained from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103. Specifications may also be purchased and downloaded from the internet at: http://webstore.ansi.org/SdoInfo.aspx?sdoid=41&Acro=ASTM&DpName=ASTM%20Int ernational&source=googe&keyword=astm&gclid=CPuey-Sy1boCFe5cMgodMi0AIA
b. Testing may be performed by private testing labs, utility companies, and large military
and Federal establishments.
c. Gloves should be proof-tested at the following intervals:
• In daily use – 30 days. • Infrequently used – 180 days.
d. Visually inspect hot sticks for paint smears, carbon paths, dirt smears, etc., and clean
them, if required, prior to use. Re-surface and test hot sticks that cannot be cleaned and/or have significant surface-coating ruptures.
Note: Wear certified rubber gloves (ASTM D120) and protective leather gauntlets whenever hot sticks are used.
2.7 Safety Checklist.
Perform a safety inspection on a monthly basis to ensure that the safety boards contain all required items and that test equipment is in a safe operating condition. Retain the completed checklist on file for at least one year.
2.8 Safety Equipment in Vehicles.
All vehicles operated on the airfield should have a properly sized fire extinguisher and first aid kit. Equip all vehicles and/or personnel with radio communication to be available to summon help in an emergency. Mark and register all vehicles appropriately. Equip all vehicles with a lighted warning beacon (see AC 150/5210-5, Painting, Marking, and Lighting of Vehicles Used on an Airport, for additional information about airport vehicle mounted beacons).
2.9 Electric Shock.
An electric shock is the passing of an electric current through a person. The amount of damage depends on the amount of voltage and current to which the person is subjected.
a. Voltages between 200 and 1000 volts at commercial power line frequencies are
particularly harmful since, under these conditions, heart muscle spasm and paralysis of
the respiratory center occur in combination. However, lower voltages can also prove fatal, as evidenced by records of deaths caused by 32 volt farm lighting systems. The body response to current is a follows: • 5 to 15 mA stimulates the muscles • 15 to 19mA can paralyze the muscles and nerves through which it flows • 25 mA and above may produce permanent damage to nerve tissues and blood vessels • 70 mA and above may be fatal.
Chapter 2. Safety. › 2.11 Safety Warning Signs/Danger Tags.
b. The injurious effects suffered during electric shock depend upon the path of the current
through the body. The current path will take the most direct route through the body from the two points of contact. For this reason, any current path which involves the heart or the brain is particularly dangerous. Therefore, keeping one hand clear of the equipment will eliminate the possibility of a current path from arm to arm.
2.10 Safety Training.
Establish a safety training course and conduct for all employees. Conduct follow-up training on a periodic basis to ensure that employees are safety motivated. Include first aid and CPR (Cardio-Pulmonary Resuscitation) training in the safety training course. The safety course must include driver safety training (see AC 150/5210-20, Ground Vehicle Operations on Airports) and proper procedures on contacting local emergency, police, and fire agencies.
2.11 Safety Warning Signs/Danger Tags.
The following discusses the use of warning signs on high voltage equipment.
2.11.1 Warning Signs.
Permanently place “DANGER – HIGH VOLTAGE” signs on all fixed electrical equipment where potentials of 500 volts or more terminal-to-ground are exposed. Place signs in a conspicuous location, usually on the outside of the equipment.
Figure 2-2. Example of a “Danger – High Voltage” sign
2.11.2 Lock-Out/Tag-Out and Danger Tags.
Every airport electrical maintenance department must have a written lock-out/tag-out procedure. Equipment or circuits should never be worked on unless they are locked out and tagged by the person performing the work. In these situations, make it a rule to never trust anyone but yourself. Have your partner check behind you to make sure the proper equipment is turned off.
The lock-out tag should only be removed by the person who signed it except in some circumstances when verbal permission has been granted to another person or when the worker who signed the tag is on vacation, etc. Never rely on the air traffic controllers to assure electrical safety. Air traffic controllers are relieved periodically and the next person may not know of the work that is going on.
Always take whatever time is necessary to make sure that the circuit or equipment you are working on is safe. One of the primary reasons for accidents is when workers get in too great a hurry and don’t take proper precautions and follow proper safety procedures. Always follow safety procedures and never become negligent or lax because you are doing the “same old job” on a daily basis.
Figure 2-3. Examples of Danger Tags
2.11.3 Locks and Padlocks.
Use built-in locks on switchgear and disconnecting switches whenever the equipment is tagged, and return the keys to the supervisor responsible for their control. Padlocks need not be used if it is decided that use and control of them would be difficult because of the type of switchgear and its location. However, use padlocks with “DANGER” tags attached when equipment or electrical lines remain out of service or when electrical work has been discontinued until a later date. When outside contractors are involved, each contractor should attach and control tags and locks independently.
Figure 2-3 · page 22Picture of the page from the copy saved here
Chapter 2. Safety. › 2.14 Lightning.
2.12 Grounding and Bonding.
Never remove, alter, or attempt to repair conductors or conduit systems providing grounding or electrical bonding for any electrical equipment until all power is removed from equipment. Warn all personnel of the ungrounded condition of the equipment. Display appropriate warning signs, such as danger tags, to warn personnel of the possible hazards.
2.13 Confined Spaces.
Be sure to have a plan in place for dealing with confined spaces that conforms to OSHA standards. Make sure to test the air quality and use an approved blower to ventilate any confined spaces before entering. This includes any unventilated space especially manholes and storage tanks. Remember that gases produced by rotting materials, both vegetable and animal, will displace oxygen. These materials can be commonly found in airport lighting manholes. When working in manholes and storage tanks with vertical access, personnel must wear proper Class II or Class III harnesses and be connected to a rescue tripod-mounted winch mounted above the entrance. Use forced air blowers with flexible ducts to provide fresh air to confined spaces. Keep vehicles away from air intakes for blowers. Vehicle exhaust can quickly contaminate the quality of the forced air.
2.14 Lightning.
When personnel are subjected to direct lightning strikes, the results are nearly always fatal. Although extraordinary escapes from direct strikes have been reported, the shock is usually so great that survival is rare. The major portion of lightning casualties arises from secondary effects, such as side flashes and induced charges.
Note: If administered in time, first-aid treatment, especially artificial respiration or cardiopulmonary resuscitation may prevent death.
Assess your lightning risk and take appropriate actions. During thunderstorms, no place outside is safe. If you can hear thunder, lightning is close enough to strike. Stop what you are doing and seek safety in a substantial building or a hard-topped metal vehicle.
Lightning: What You Need to Know
• NO PLACE outside is safe when thunderstorms are in the area!!
• If you hear thunder, lightning is close enough to strike you.
• When you hear thunder, immediately move to safe shelter: a substantial building with electricity or plumbing or an enclosed, metal-topped vehicle with windows up.
Stay in safe shelter at least 30 minutes after you hear the last sound of thunder.
For additional information about lightning safety see: www.lightningsafety.noaa.gov/tips.htm
2.15 Toxic Agents.
Toxic agents are poisonous substances that can cause injury by contact or injection. Substances termed “caustic” or “corrosive” cause the flesh to be dissolved on contact; the results of contact with these agents range from minor skin irritations to severe burns. There are materials that are toxic only if they are taken internally. Toxic agents also exist as a gaseous vapor and may be injurious immediately or over a long period of time. There are also a few substances used in electric equipment that are basically non-toxic agents, but under certain conditions can become highly toxic.
Chapter 2. Safety. › 2.16 Fire Extinguishers.
2.15.1 Carbon Tetrachloride.
Never use carbon tetrachloride. Contact with liquid carbon tetrachloride destroys the natural oils of the skin, producing a whitish appearance on skin surfaces that are exposed. Continuous skin exposure may cause skin eruptions. Carbon tetrachloride fumes are highly toxic.
2.15.2 Trichloroethylene.
This agent, used principally as a degreasing solvent, is a narcotic and anesthetic material. Organic injury rarely results from overexposure, but repeated overexposure can cause anemia and liver damage.
2.15.3 Battery Acids.
The most common battery acid is sulfuric acid. Sulfuric acid is a corrosive toxic agent; repeated or prolonged inhalation of its fumes can cause inflammation of the upper respiratory tract, leading to chronic bronchitis. Loss of consciousness with severe damage to the lungs may result from inhalation of concentrated vapors when the sulfuric acid is hot. Sulfuric acid, when used in a highly concentrated form (prior to adding water for battery use), acts as a powerful caustic, destroying skin and other tissue on contact. This destruction appears as severe burns, and such exposure may be accompanied by shock and collapse. The fumes from highly concentrated sulfuric acid cause coughing and irritation of the eyes; prolonged exposure may produce chemical pneumonitis.
Batteries and battery acid also produce hydrogen gas, a by-product of the charging process. Hydrogen gas, when mixed with air in the right proportions, is highly flammable and can react explosively in conjunction with a spark or flame.
All locations where lead-acid batteries are used or housed should have, as a minimum, an emergency eyewash station installed. If water is not readily available, portable emergency eyewash stations consisting of a wall mountable water bottle should be made readily available.
2.16 Fire Extinguishers.
Conveniently locate fire extinguishers of the proper type (see paragraph 2.15.4), and in good working condition, near all high-voltage equipment. For additional details about fire extinguishers, see NFPA 10, Standard for Portable fire Extinguishers.
2.16.1 A Brief Introduction to Fire Extinguishers and Fire Types.
When used properly, portable fire extinguishers can save lives and property by extinguishing or containing a small fire until the fire department arrives.
Portable fire extinguishers, however, are not designed to fight large or spreading fires. Even for small fires, they are useful only under certain conditions:
• The operator must know how to use the extinguisher. There is no time to read directions during an emergency. • The extinguisher must be within easy reach and in working order, fully charged. • The operator must have a clear escape route that will not be blocked by fire. • The extinguisher must match the type of fire being fought. Extinguishers that contain water are unsuitable for use on grease and electrical fires. • The extinguisher must be large enough to put out the fire. Many portable extinguishers discharge completely in as few as 8 to 10 seconds.
2.16.2 How to Use Portable Fire Extinguishers.
Remember the PASS system:
P…Pull the Pin A…Aim the extinguisher nozzle at the base of the flames S…Squeeze trigger while holding the extinguisher upright S…Sweep the extinguisher from side to side
ALWAYS make sure the fire department is called and inspects the fire site, even if you think you have extinguished the fire!
2.16.3 Should You Try to Fight the Fire?
Before you begin to fight a fire:
• Make sure everyone has left or is leaving the building • Make sure the fire department is called • Make sure the fire is confined to a small area and is not spreading • Make sure you have an unobstructed escape route to which the fire will not spread • Make sure you have read the instructions and know how to use the extinguisher.
It is reckless to fight a fire in any other circumstances. Instead, leave immediately and close off the area.
2.16.4 Class of Fire Extinguishers.
Fire extinguishers are divided into four categories that are based upon different types of fires. Each fire extinguisher also has a numerical rating that serves as a guide for the amount of fire the extinguisher can handle; the higher the number, the more fire-fighting power. The following is a quick guide to help choose the right type of extinguisher:
• Class A extinguishers are for combustible materials such as paper, wood, cardboard, and most plastics. The numerical rating on these types of extinguishers indicates the amount of water it holds and the amount of fire it can extinguish.
• Class B fires involve flammable or combustible liquids such as gasoline, kerosene, grease and oil. The numerical rating for Class B extinguishers indicates the approximate number of square feet of fire it can extinguish.
• Class C fires involve electrical equipment, such as appliances, wiring, circuit breakers and outlets. Never use water to extinguish Class C fires – the risk of electrical shock is far too great! Class C extinguishers do not have a numerical rating. The C classification means the extinguishing agent is non-conductive.
• Class D fire extinguishers are commonly found in a chemical laboratory. They are for fires that involve combustible metals, such as magnesium, titanium, potassium and sodium. These types of extinguishers also have no numerical rating, nor are they given a multi-purpose rating – they are designed to Class D fires only.
Some fires may involve a combination of these classifications.
2.16.5 Most Common Types of Fire Extinguishers.
a. Water extinguishers or air-pressurized water (APW) extinguishers are suitable for Class
A fires only. Never use a water extinguisher on grease fires, electrical fires or Class D fires – the flames will spread and make the fire bigger! Water extinguishers are filled with water and pressurized with oxygen. Again – water extinguishers can be very dangerous in the wrong type of situation. Fight the fire only if you are certain it contains ordinary combustible materials.
b. Dry chemical extinguishers come in a variety of types and are suitable for a
combination of Class A, B and C fires. These are filled with foam or powder and pressurized with nitrogen.
(1) BC - This is the regular type of dry chemical extinguisher. It is filled with sodium
bicarbonate or potassium bicarbonate. The BC variety leaves a mildly corrosive residue which must be cleaned immediately to prevent any damage to materials.
(2) ABC – This is the multipurpose dry chemical extinguisher. The ABC type is filled
with monoammonium phosphate, a yellow powder that leaves a sticky residue that may be damaging to electrical appliances such as a computer.
Dry chemical extinguishers have an advantage over CO2 extinguishers because they leave a nonflammable substance on the extinguished material, reducing the likelihood of re-ignition.
Carbon Dioxide (CO2) extinguishers are used for Class B and C fires. CO2 extinguishers contain carbon dioxide, a non-flammable gas, and are highly pressurized. The pressure is so great that it is not uncommon for bits of dry ice to shoot out the nozzle. They don’t work very
Chapter 2. Safety. › 2.17 First Aid.
well on Class A fires because they may not be able to displace enough oxygen to put the fire out, causing it to re-ignite.
CO2 extinguishers have an advantage over dry chemical extinguishers because they don’t leave a harmful residue – a good choice for an electrical fire on a computer or other electronic device.
It is vital to know what type of extinguisher you are using. Using the wrong type of extinguisher for the wrong type of fire can be life-threatening.
2.17 First Aid.
First aid is performed before the doctor arrives - it is never a substitute for qualified medical help. The maintenance technician should perform the lifesaving measures necessary in emergencies, but avoid doing any harm. Many first-aid measures are quite simple and do not require “split-second speed” in their application. Haste without knowing what one is doing can be worse than doing nothing at all. At other times, immediate action is essential to save a life or prevent serious complications; this action can only be taken by someone who is on the scene when minutes are vital. Learn about first aid before emergencies happen. Be prepared to give help safely and beneficially when necessary. Contact the American Red Cross to provide refresher first-aid courses to maintenance personnel to keep them proficient.
Intentionally Left Blank
Chapter 3. Maintenance Management. › 3.1 Maintenance Schedule.
Chapter 3. Maintenance Management.
3.0 Maintenance Philosophy.
The purpose of the maintenance management system is to ensure the maximum availability of any given system at a minimum cost in man-hours or funds. “Availability” and “costs” are relative terms; they must be interpreted for each airport. For example, a CAT I runway may still be considered operational with 15% of the edge lights out, while a PAPI system may be unserviceable with more than one lamp out per box.
By the same reasoning, the cost of maintaining a spare regulator may be considered cost prohibitive, while stocking replacements for 10% of the runway edge lights may be considered a normal practice. In addition, operational factors are a major consideration in determining what maintenance is required. Airports with heavy traffic may require more frequent maintenance servicing than those with light traffic. The maintenance operations include maintenance planning, preventive maintenance inspection, visual inspection, repair, installation, calibration, and unscheduled maintenance procedures.
Maintenance procedures, including the work order and documentation required, may vary between airports. The purpose of this document is to provide the minimum maintenance procedures required for safe and efficient movement of aircraft during takeoff, landing, and taxiing operations.
Regardless of the actual maintenance routines decided upon, the following elements are essential to any controlled maintenance program. The maintenance procedures in this AC are considered minimum guidelines:
a. Document the service checks that comprise the maintenance program.
b. Record the performance of each maintenance action, scheduled or unscheduled.
c. Document repairs and troubleshooting performed on each piece of equipment and the
results of those actions as well as the symptoms related to the malfunction. This allows for more rapid troubleshooting of similar problems at a later date.
3.1 Maintenance Schedule.
Documenting the maintenance schedule by spelling out each item of routine maintenance is beneficial in several ways:
a. It allows planned allocation of man-hours to the maintenance function.
b. It helps to establish spare part stock levels.
c. It identifies the necessary maintenance routines to new employees, decreasing training
time needed for system familiarization.
d. It identifies the scope of the maintenance task in terms of man-hours and material
Chapter 3. Maintenance Management. › 3.3 Preventive Maintenance Program.
requirements.
3.2 Maintenance Records.
Maintenance records are an important part of an effective maintenance management system; they provide a service history of each piece of equipment, ensure regular maintenance without duplication of effort, and provide a data base for statistical analysis of lighting system performance. Without records, knowledge gained from regular inspections will not be retained, and preventive maintenance will be difficult.
An effective records system should allow for the recording and retrieval of information with a minimum of effort. The records system should compile data that will document the effectiveness of the maintenance program. By checking the records, a manager should be able to determine whether a particular maintenance task is being done too frequently or not often enough. By such a trial-and-error process, a maintenance program uniquely tailored to the facility can be developed.
3.2.1 Maintenance Logs for Lighted Navigational Aids - PAPIs, VASIs, REILs, or ODALS.
To ensure that visual lighting aids are properly maintained, maintenance logs (see example in appendix B) should be kept for all non-federal lighted navigational aids (precision approach path indicators (PAPIs), visual approach slope indicators (VASIs), runway end identifier lights (REIL), and omnidirectional approach light systems (ODALS)). The maintainer of these facilities, if different from the airport sponsor/owner, should provide copies of the completed maintenance log to the airport manager to be filed at the airport.
Upon completion of scheduled maintenance/inspections, the airport sponsor/owner should include a written statement in the maintenance log declaring that:
• maintenance/inspection of the subject facility has been performed per the applicable sections of Chapter 5 of this advisory circular,
• the facility is per equipment manufacturer’s specifications
• the facility is per Appendix A (Standards and Tolerances, Tables 3, 6, and 7) of this advisory circular.
All facility maintenance logs should be retained per the requirements in Chapter 3, Maintenance Management, of this AC. Guidance for the proper completion of a maintenance log and examples of maintenance log content are in appendix B.
3.3 Preventive Maintenance Program.
Reliable functioning of airport lighted visual aids is essential to airport safety, capacity, and operation especially for low visibility operations. Therefore, it is essential that a preventive maintenance program be established to ensure reliable service and proper equipment operation.
Properly scheduled inspections, testing, and calibrations are essential to the proper functioning of these systems. Airport lighting systems are designed to be dependable and may continue to operate for long periods of time despite neglected maintenance. Eventually a failure will occur and, if the failure occurs at a critical time, safety may be jeopardized. Lighted visual aid maintenance should receive high priority to prevent equipment failure, false signals, and overall deterioration of the system.
3.3.1 Installation and Material.
The most important element in a preventive maintenance program is high quality, properly installed equipment. Preventive maintenance is difficult on equipment that has been installed haphazardly without consideration of maintenance requirements. When such conditions exist, they should be brought to the attention of the proper authority and corrected rather than trying to establish a preventive maintenance program to compensate for the condition.
Consult the electrical maintenance supervisor at an airport prior to and during the design of any installation of new or additional visual aid systems. By so doing, the airport can avoid costly problems during and after construction. Consideration should also be given to the method of selection and training of any contractor personnel involved in the installation of airfield lighting products. The need for specialized training for airport maintenance electricians applies to the contractor personnel also.
3.3.2 Personnel.
The second element in a preventive maintenance program is trained and experienced personnel. Maintenance personnel should have a thorough knowledge of the equipment, experience with high voltage, and should be able to perform inspections and repairs. Special training is available and may be desirable, as most well-qualified electricians can be trained on-the-job if suitable supervision and instruction are provided. Qualified maintenance individuals should be present, or on-call, during the operating hours of the airport to correct any deficiencies that may develop. Airport visual aid maintenance personnel should be specialists in the field.
3.3.3 Tools and Test Equipment.
The third element in a preventive maintenance program is the tools and test equipment required to perform the maintenance. This includes specialized tools and test equipment, adequate working space, adequate storage space, spare parts, and applicable technical manuals.
3.3.4 Preventive Maintenance Inspection Program.
The fourth element in a preventive maintenance program is an effective inspection schedule for each visual aid. The schedule should also include all cable systems that are associated with visual aids. The preventive maintenance inspection (PMI) schedule is the foundation for the successful maintenance of the equipment. If the PMI is performed properly and at the scheduled time, it will ensure top system performance and will minimize unscheduled interruptions and breakdowns. Reviews of the inspection records, checks, tests, and repairs provides a constant awareness of the equipment condition and gives maintenance personnel advanced warning of impending trouble.
Chapter 3. Maintenance Management. › 3.5 Reference Library.
3.3.5 Preventive Maintenance Inspection Schedule.
Scheduled inspections and tests are those accomplished on specific types of equipment on a periodic basis. The schedule may be based either on calendar or on hourly-use increments. The PMI schedules, based upon recommendations from the manufacturers and users of the equipment, are considered to be the typical requirements to keep the equipment in good condition. Adjust the frequency of a particular PMI after experience is gained under local operating conditions.
3.4 Record Retention.
There is no set period of time that maintenance records should be kept, but in keeping within the goals mentioned above, a period of twice the longest period recorded would appear to be the minimum (i.e., 2 years in the case of annual maintenance action). Records of daily inspection will, of course, lose their significance much sooner, probably within a month. It should be noted however, that maintenance records should be retained permanently, if possible, because situations may develop years later when those records can prove invaluable.
3.5 Reference Library.
Establish a reference library to maintain a master copy of all Equipment Technical Manuals (ETMs), ACs, as-built drawings, and other useful technical data. The electrical supervisor should establish and maintain responsibility for maintaining the technical reference library and ensure that technical manuals and drawings are kept up to date and not lost or damaged.
3.5.1 Equipment Technical Manuals (ETMs).
ETMs and other manufacturer’s literature form an important part of the reference library. Obtain three copies of all technical manuals and related manufacturer’s literature. Retain a master copy in the reference library and provide a separate copy for the shop. In addition, keep a copy of each equipment manual at the equipment location. This facilitates troubleshooting and repairs without traveling back to the shop location to retrieve the manual.
Do not remove the master copy of the technical manual from the reference library because it can easily become misplaced or lost. In the event the shop copy is lost, make another photocopy of the technical manual from the reference library instead of releasing the master copy.
3.5.2 Advisory Circulars.
Important reference information about installation, design tolerances, and operation of visual aid equipment may be found in FAA ACs. Include a copy of the ACs for the equipment at the facility, along with a copy of this AC, in the reference library.
3.5.3 Other Technical Data.
Other reference information that is occasionally useful should also be added to the library. This might include local electrical codes, engineer’s handbooks, test equipment manuals, and other general information publications.
Chapter 3. Maintenance Management. › 3.6 Spare Part Provisioning.
3.5.4 As-Built Drawings.
Maintain the master copy of all as-built (record) drawings as part of the reference library. Incorporate modifications to any equipment into the drawings as soon as the modification is completed. Give a copy of the “as-built” lighting plan, showing the location of all cable runs, runway lights, etc., and including the wiring diagrams for the lighting, engine generator, and the visual aid system, to the field technicians as a working copy. Install or identify test points at appropriate locations in the field circuitry and record locations of these test points on the “asbuilt” drawings. Immediately update any notations regarding test points or discrepancies in the drawings made in the field on the master set in the reference library.
3.6 Spare Part Provisioning.
This paragraph contains guidelines on how to establish a stock of spare parts to be used for quick repair of lighting equipment that fails unexpectedly. The purpose of a spare parts system is to have the necessary part on hand when a piece of equipment fails; this will minimize the time the system is out of operation. However, the greater the number of spare parts stored, the greater the inventory costs. The optimum spare part system balances the cost of system downtime (lost operation, tenant inconvenience, safety, etc.) with the cost of purchasing and storing spare parts.
A small airport with few operations may suffer little inconvenience with the loss of their lighting system and may, therefore, choose to stock few spare parts. A large airport may rely heavily on its lighting system for low visibility operations and would, therefore, require a substantial quantity of spare parts. In the case of a large airport, the funds lost by the tenants due to interrupted operations and the impact on the safety and security of the traveling public must also be taken into consideration. A malfunction at a major airport can have a far reaching effect on the national airspace system. When establishing a spare parts inventory, two questions must be answered:
(1) What parts should be stocked?
(2) How many of each part?
When new construction occurs or a project is funded for replacement of existing systems, fund and include a quantity of spare parts (light fixtures, lamps, fuses, relays and spare CCR control boards, etc.) in the equipment furnished by the contractor. This gives the maintenance department a built-in stock of spare parts and lessens the time required to procure parts for the new equipment. This is especially true if the equipment being installed is different from what is currently in use.
3.6.1 Choosing Spare Parts.
To answer the two questions posed above, several factors must be considered, including failure rate, part availability, and effect of the part failure on airport and flight operations.
3.6.2 Failure Rate.
The failure rate (or replacement rate) is the product of the expected life of an item and the number of items in the system. For instance, if a lamp is expected to last six months, and we have 100 lamps in the system, then an average of 100 lamps will be replaced every six months or approximately four per week. Accurate records of parts used over time will help immensely in determining a failure rate.
3.6.3 Part Availability.
Part availability refers to the time required to secure a replacement part. This usually means procurement lead time. If a part can be readily procured from shelf stock of a local supplier, it might not be necessary to add the part to the spare parts inventory; as it could be purchased when needed or the number of spare parts in the inventory could be reduced. However, if there is a six-week lead time required by the supplier, then stock six times the weekly failure rate (24 lamps in the example above). Spare parts for constant current regulators and other special equipment fall into this category. For instance, a replacement printed circuit board or other assembly typically has a six to twelve week lead time and unless a spare regulator is maintained for emergency use, the loss of a circuit could have a serious effect on airport operations.
There are methods of obtaining parts which may reduce the effect of a long lead time. These include substitution (the use of a functionally equivalent part from another manufacturer), cannibalization (replacing one of a pair of adjacent failed lamps by “borrowing” a lamp from elsewhere in the system), and temporary fixes (such as the use of portable lights in place of the fixed light installation) while awaiting corrective maintenance. It should be noted, however, that these solutions should be considered only as an emergency measure and that proper spare parts provisioning will eliminate the need for such techniques.
3.6.4 Effect of the Failure.
The effect of the failure of a particular spare part depends on how important the part is to the equipment operation and how vital the equipment is to airport operations. The failure of a lamp in an edge light would not lead to any system downtime, but the failure of a circuit board in a constant current regulator would cause the loss of the entire lighting circuit that it powers. The equipment manufacturer will give guidance on recommended spare parts. As experience is gained with the system, other parts may be added or deleted from the inventory. The impact of a part’s failure should be considered when building a spare parts inventory.
3.6.5 Part Identification.
An important part of maintaining a spare parts inventory is accurately cataloging the parts on hand by manufacturer’s part number. This is important to ensure that the correct part is used in a broken piece of equipment; many optical parts are visually similar but vary significantly in performance. The use of the manufacturer’s part number is also vital when reordering; if a part is ordered by its generic name, the manufacturer may send a later version of the part which is incompatible with the existing system. It is extremely important to maintain manufacturer’s data which reflects your equipment, describing the type, model number, and serial number details.
Chapter 3. Maintenance Management. › 3.7 When Lighted Navigational Aids are Identified as Suspect in an…
3.6.6 Use of Original Equipment Manufacturer (OEM) Part.
The use of non-OEM parts or lamps in FAA approved equipment is strongly discouraged. The FAA has strict specifications for approval of all airport lighting equipment and use of non-OEM parts or lamps in such equipment or systems can render the equipment to be functionally non- FAA approved. This could possibly lead to serious liability consequences in case of an aircraft incident at an airport following these practices. In the case of runway and taxiway lighting fixtures, the use of a generic, non-approved lamp can render the photometric output of the fixture out of specification and adversely affect the safety of low visibility operations.
3.7 When Lighted Navigational Aids are Identified as Suspect in an Aircraft Accident.
When notified by the FAA that a lighted navigational aid is declared out of service due to being suspect in an aircraft accident, the airport sponsor/owner/operator should:
• Immediately inspect the affected facility and record as found all functional parameters per the appropriate table of Appendix A, Standards and Tolerances, of this AC.
• Retain the as-found inspection record (technical performance record) per paragraph 3.4 of this AC and store it at the airport manager’s office (on site at the airport) for ready access by authorized personnel.
• Prepare a maintenance log entry and include a written statement that a facility “as-found inspection” is complete. The airport sponsor/owner/operator should also state that the equipment is functional per the manufacturer’s standards, tolerances, and specifications. The statement should be delivered to the airport manager for filing in the airport manager’s office.
• Contact the Operations Control Center (OCC) to cancel the NOTAM. NOTAM cancellation should be per FAA JO 7930.2, current revision.
Intentionally Left Blank
Chapter 4. Test Equipment. › 4.1 Types of Equipment and Usage.
Chapter 4. Test Equipment.
4.0 Introduction.
An electrician may have little day-to-day use for anything more than a voltmeter; however, when maintaining airport lighting series circuits, the equipment needs become more demanding. An airport electrician needs to be able to perform many tasks involving troubleshooting and calibration that are typically out of the norm for the average wireman. Series circuits operate at potentially high voltages and are prone to develop shorts and opens that require an advanced knowledge of the use of ohmmeters and insulation resistance testers (meggers) to properly trace the problem and get the lighting circuits back up and operating in a minimum of time.
There is also a need for current measurements at relatively low currents (<20 amps) that require accurate and calibrated equipment. A small change in the output current in a series circuit can have a large effect on light output and lamp life. At maximum output of 6.6 amps at the lamp, a current change (increase or decrease) of 1% can change the light output of the lamp by as much as 5%. That same 1% change (increase) can result in a 20% decrease in lamp life.
Accurate test equipment and proper knowledge of its usage are vital to the maintenance of the airfield lighting system. Due to the non-sinusoidal output waveform of many constant current regulators, it is imperative to verify the accuracy of all current measuring devices. Evaluate all equipment used for the calibration of regulators and have the equipment calibrated for the values to be measured (2.8 – 20 amps) by a certified calibration lab.
For maintenance purposes, it is recommended that every airport acquire at least a volt-ohmmeter, an insulation tester and an accurate true RMS measuring clamp-on AC ammeter or true RMS digital multimeter with an accurate clamp-on ammeter probe. These units are useful for various maintenance routines and are necessary for troubleshooting and calibration of constant current regulators and series lighting circuits.
4.1 Types of Equipment and Usage.
4.1.1 Volt-Ohm-Milliammeter (VOM).
An analog VOM is a highly versatile piece of test instrument that is capable of measuring AC/DC voltages, resistance, and low values of DC current. The better quality units offer reasonable accuracy and ruggedness and are useful for making a large variety of measurements. The most common use of this instrument is for making resistance measurements on series circuits for the purpose of troubleshooting when a fault has occurred. An analog VOM is useful because of its ability to show fluctuating trends and rates and the ease with which it offers a go, no-go check when rapid troubleshooting is required. An analog VOM does have limitations however. Its relatively low-input impedance and susceptibility to interference make it unsuitable for some measurements, especially when dealing with electronic circuits or when working in an environment with RF (radio frequency) energy present. Also it must be remembered that a typical VOM should not be used for making current measurements in an airfield lighting series circuit because it may not be designed for true RMS, high accuracy measurements.
4.1.1.1 Safety.
Safety must always be considered when using a VOM. Know the voltage levels and shock hazards related to all equipment to be tested. Be sure that the VOM has been tested and calibrated. Inspect and calibrate portable test instruments at least once a year. Check the condition of the VOM test leads before making any measurement. General recommendations for specific uses of a VOM are contained in the manufacturer’s manual supplied with the equipment.
a. High-voltage measurements. Never try to take direct voltage measurements on power
distribution circuits rated over 600 volts. Measurement of high voltage is accomplished by installing properly rated instrument transformers and meters.
b. Switch settings. When making voltage measurements on power and control circuits, be
sure that the meter selector and range switches are in the correct position for the circuit under test before applying test leads to the circuit conductors. To prevent damage to the meter movement, always use a range that ensures less than full-scale deflection of the pointer. A 1/3 to mid-scale deflection of the pointer assures the most accurate readings.
c. Case insulation. Do not hold the VOM in the hand while taking the reading. Support the
instrument on a flat surface. If holding the VOM is unavoidable, do not rely upon the insulation of the case.
4.1.2 Digital Multimeter (DMM).
A DMM is another piece of essential test equipment for the airport electrician’s toolbox. This versatile instrument can deliver high accuracy and, through the use of various accessories, the ability to make a wide range of measurements. The best advice when purchasing this or any type of test equipment is to buy the best you can possibly afford. Always make sure that the DMM you use is a true RMS type and that the accessories are of the highest accuracy (see paragraph 4.1.5).
A DMM with a good quality clamp on ammeter accessory is a good combination for measuring the output current of constant current regulators. Verify that all DMM accessories are within the accuracy requirements for the intended task. Ensure that the accuracy of the DMM and all accessories are checked and calibrated annually by a certified calibration lab for the ranges to be measured. In the case of airport lighting series circuits, 2.8 to 20 amps is the range for verifying proper calibration.
All safety precautions listed for VOMs also apply to DMMs.
4.1.3 Insulation Resistance Tester (MegOhmMeter).
The insulation resistance tester or megohmmeter is a necessary tool for maintaining and troubleshooting underground airport lighting series high voltage cables. Insulation resistance testers come in a variety of styles from the traditional hand-crank models to battery and AC mains powered versions. These instruments are used for testing the insulation resistance-toground of underground cables; for testing insulation resistance between conductors; and for testing resistance-to-ground or between windings of transformers, motors, regulators, etc. The
battery powered models are the most prevalent and come in all shapes and sizes in both analog and digital readout. Most of the digital models have an analog bar graph to supplement the digital reading. Another consideration in selecting an insulation resistance tester is the output voltage.
Some battery and line powered units now have selectable output voltages that can range as high as 5000 volts DC. As a minimum, select an insulation resistance tester with an output of 1000 volts DC.
4.1.3.1 Safety.
a. When preparing to make an insulation resistance test, first make a complete safety check.
Make sure that equipment to be tested is disconnected from all power sources. Open all safety switches and lock out other control equipment so that the equipment cannot be accidentally energized.
b. If neutral or ground conductors must be disconnected, make sure they are not carrying
current and that, when disconnected, no other equipment will lack protection.
c. Observe the voltage rating of the tester and take suitable precautions.
d. Large equipment and cable usually have sufficient capacitance to store a dangerous
amount of energy from the test current. After taking resistance readings and before handling the test leads, allow any energy stored in the equipment to discharge by leaving the tester connected for at least 30 seconds before touching the leads. Many new testers will automatically discharge the equipment under test and give the user a visual or audible indication when it is safe to remove the test leads. Consult the equipment manual for information on manufacturer’s instructions.
e. Do not use the tester in an explosive atmosphere. An explosion may result if slight
sparking is encountered when attaching or removing test leads, or as a result of arcing through or over defective insulation.
4.1.4 Underground Cable/Fault Locators.
A cable locator is an indispensable tool for quickly locating airport lighting cable and ducts. A cable locator normally consists of a transmitter which is either directly (or indirectly by means of an inductive coupler) attached to an underground cable and a receiver that is used to pick up the transmitted signal to follow the path of the cable. Cable locators are very handy for locating the path of a conductor while troubleshooting cables in PVC conduit and are even more necessary when dealing with direct buried cables.
Whenever work on the airport requires digging of any kind, it is necessary to utilize a cable/fault locator to prevent inadvertent cutting of cables. Most of the receivers also incorporate the ability to locate 60 Hz AC cables without the necessity of applying a signal or tone to the conductor. If the airport circuits are supplied by direct-buried conductors or have direct-buried control cables, it is advisable to purchase a locator which also has the capability of locating ground faults. It should be noted, however, that faults in cables installed in conduit cannot be located using these
devices. Cable locators that include fault-finding capability are normally equipped with an Aframe probe that is used with the receiver to determine the direction of a fault between the conductor or shield to ground.
4.1.4.1 Safety.
When using a direct connection to the conductor to be located or tested, always exercise care to ensure that the circuit supplying the conductor has been de-energized and locked out, and tagged.
4.1.5 Clamp-on Ammeter.
The stand-alone clamp-on ammeter is useful for measuring AC and sometimes DC current. Most of the modern instruments of this type are provided with plug-in leads to permit the instrument to be used as a voltmeter or as an ohmmeter. Ensure that the unit is a true-RMS type so it can measure the distorted waveform output of some constant current regulators. The same warnings apply to these devices as to the DMM/clamp-on combination when it comes to accuracy of the instrument. Because most of these devices are rated to measure current far in excess of what you need to measure on airport lighting circuits, their accuracy at the low end of the measurement scale may be in question – this may be particularly true for lighting circuits that use LED lamps. Clamp-on devices having an accuracy of ±2% or better should be used because a small change in series circuit lamp current can produce a large change in lamp light output and potentially shorten lamp life. It may be beneficial to have a registered calibration laboratory check the instrument and calibrate it to the lower amp range.
4.1.5.1 Safety.
A clamp-on ammeter reduces operator exposure to high voltage. However, the operator must observe normal safety precautions to prevent coming in contact with exposed conductors when taking current readings.
4.1.6 AC Proximity Voltage Tester.
These small non-contact testers, sometimes referred to as “tickers,” can be handy for detecting voltage present in insulated cables. Depending on the model, they may have a wide measurement range. They should not, however, be used to determine if an airfield lighting series circuit is energized (4.1.6.1). The reason for this is because of the behavior of voltage in a series circuit. The voltage is reduced by the various voltage drops (loads) present in the circuit until at some point near the middle of the circuit there is no measurable voltage although current flow is still present. Breaking a live series circuit at any point can result in injury or death. See paragraph 2.3.1.
4.1.6.1 Safety.
Do not rely on these units as the only instrument used to protect oneself from coming into contact with energized conductors. A good quality clamp-on ammeter device is the only safe way to check for an energized series lighting conductor. After checking for the presence of current with a clamp-on ammeter, an inductive proximity voltage measuring device may be used to detect the presence of induced voltage. Also, as with all test instruments used for measuring
voltage or current, make sure that you test the device on a known live circuit before and after making any measurement of this kind.
4.1.7 Time Domain Reflectometer.
The Time Domain Reflectometer (TDR) was once a very expensive laboratory quality instrument used for testing control and coax cable systems. However, these instruments have evolved into less expensive hand-held units capable of pinpointing the location of opens or faults in long runs of twisted pair control cables. If your facility is using long runs of telephone type twisted pair cables for control of airfield lighting equipment from a remote control tower location, it may be useful to invest in one of these devices for troubleshooting purposes. The TDR applies a signal to the cable pair in question and can give readout in feet indicating the distance to the cable fault as well as a visual display of the cable run. This can save many hours of troubleshooting when trying to find a bad splice in a long run of control cable. The newest models have settings for testing power cables, data cables, coax cables, as well as telephone and control cables. Some of these units are capable of measuring cable lengths of up to 48,000 ft.
A similar device is the Optical Time Domain Reflectometer which is used to perform similar tests on optical fiber cable. With the advent of computerized control systems employing fiber optic networks for control of airfield lighting systems, the ability to troubleshoot these cable systems is becoming necessary. At the time of this writing, these instruments are still extremely high in price and probably not a justifiable expense to the average airport maintenance department. In most cases it may be more economical to employ outside contractors to perform any troubleshooting and repairs on fiber optic cable systems.
4.1.7.1 Safety.
For other measurement devices that require direct connections to conductors, be sure to exercise a proper safety check to verify that the conductor or circuit under test has been de-energized and is locked-out and tagged.
4.1.8 Tone and Probe Tracing Sets.
Normally used by technicians employed in the telephone industry, these devices can be a great addition to the airfield electrician’s toolbox. The kits are inexpensive and can be used for many purposes at an airport to identify individual conductors whether in a control cable or individual power cables in a manhole or vault. The simple transmitter is connected directly to any unenergized conductor and injects a tone on the conductor that can be heard by using an inductive probe.
4.1.8.1 Safety.
For other measurement devices that require direct connections to conductors, be sure to exercise a proper safety check to verify that the conductor or circuit under test has been de-energized and is locked-out and tagged.
4.1.9 Infrared Thermometer.
Infrared thermometers are hand-held devices that can give a direct temperature readout of any surface from several feet away. They can be aimed at the target via a laser target sight. In addition to identifying loose connections in electrical panelboards, these instruments may be used for troubleshooting ground faults in airfield lighting circuits. By measuring the temperature of different light bases on the runway or taxiway and comparing the temperature differential between light bases, it is possible to find the location of a ground fault if the cable and transformer assembly is arcing and burning inside a light base.
4.1.9.1 Safety.
Because the use of an infrared thermometer requires no contact with the surface of the object to be measured, these devices are generally very safe to use. Follow manufacturer’s instructions and avoid direct eye exposure to the laser sighting beam.
4.1.10 Portable Oil Dielectric Tester.
Most older constant current regulators (CCR) are oil filled for cooling. The oil also acts as an insulator and must be maintained. Dirt, sludge, and other contaminants will reduce the dielectric strength of the insulating oil causing a potential for failure of the transformer. Sample and test the oil per paragraph 5.2.5. A portable oil tester may be a justifiable expense if the airport maintains a large number of oil-cooled CCRs.
4.1.10.1 Safety.
Portable oil dielectric testers utilize high voltages up to 30 kV and extreme care must be taken operating this equipment. Always follow all manufacturer’s operation and safety instructions.
4.1.11 Ground Rod Resistance Tester.
Ground rod resistance testers come in several styles and are necessary for checking and maintaining the effectiveness of airport grounding and counterpoise systems. The testers measure the resistance between the grounding system and the earth ground. Some of the newer models are simple clamp-on units capable of measuring the resistance-to-ground of ground rods or grounding conductors by measuring the ground leakage current without disconnecting the grounding conductor under test. Follow the manufacturer’s instructions to obtain an accurate ground resistance reading.
The grounding system in question may be used for beacon towers, lighting vaults, engine generators, and for other lighted visual aids, or it may be a counterpoise system for underground cables. The maximum acceptable ground resistance is 25 ohms; the lower the resistance, the better. In many locations, the water table is gradually falling. In these cases, the ground electrode systems that were effective when initially installed may no longer be effective. This emphasizes the importance of a continuous program to periodically check the grounding system. It is not sufficient to check the grounding system only at the time of installation.
4.1.11.1 Safety.
A grounding system is a very important integral safety feature in airport lighting systems. To be effective, the grounding system must have a very low resistance-to-ground. When the grounding system has a high resistance, a very high voltage can build up on a grounded chassis or equipment frame. When this built-up voltage discharges through a person, injury or death may result. For this reason, check the effectiveness of the grounding system regularly.
4.1.12 Mobile Photometric Measurement System.
Maintain the light output of runway lighting systems within specified limits to provide effective visual cues to the pilot while landing in low visibility conditions. Clean or service the lights when the brightness of the fixture is less than 70% of the minimum output required when operated at full intensity, per values listed for that fixture in AC 150/5345-46, Specification for Runway and Taxiway Light Fixtures. A fixture degraded below this is ineffective for high background brightness, low visibility conditions and should be targeted for maintenance. See Appendix A, Standards and Tolerances, Table 8.
In the past, in situ photometric measurements were only possible using a hand held spot meter. This method has proven to be very ineffective and can only detect gross differences between lights and cannot account for alignment errors. Now, however, mobile systems are available which can test individual fixtures within a lighting system at high speed and with a high degree of accuracy. Some of these systems can produce individual isocandela diagrams of individual lights to aid in troubleshooting and maintenance as well as indicate misaligned fixtures. Some systems can also provide GPS coordinates for each light on the runway to aid in locating deficient fixtures for cleaning or repair. Equipment used for photometric measurements must be of the highest quality and be proven capable of high accuracy and repeatability to avoid the collection of erroneous data.
Chapter 5. Preventive Maintenance. › 5.1 Airport Lighting Vault.
Chapter 5. Preventive Maintenance.
5.0 General.
This chapter discusses the preventive maintenance program for the visual aid facilities and equipment. It includes a Preventive Maintenance Inspection (PMI) schedule for each major item of equipment with step-by-step instructions for performing the PMI. The PMIs establish a recommended routine which may be altered to suit local conditions.
This AC uses the following timeframe definitions:
• Quarterly: A period not to exceed three consecutive calendar months.
• Semi-Annually: A period not to exceed six consecutive calendar months.
• Annually: A period not to exceed twelve consecutive calendar months
General troubleshooting procedures for airport lighting systems are contained in Chapter 6. Corrective maintenance procedures for specific equipment will be found in the manufacturer's operating and maintenance instructions and are not included in this AC.
5.1 Airport Lighting Vault.
To perform the PMIs per Table 5.1, proceed as follows:
5.1.1 Daily Checks.
Check the operation of all controls. If the airport is equipped with a computer control system that allows control and monitoring from the maintenance shop or other remote location, verify the proper operation of all controls from that location.
5.1.2 Weekly Checks.
a. Cleanliness. Check the general cleanliness of the vault. Sweep out the vault regularly.
Keep it free from dust, dirt, sand, spider webs, insect nests, etc.
b. Moisture. Check for any collection of moisture. If there is a drain in the floor, make sure
that it is operating properly. Mop up moisture from the floor.
c. Screens. Check the intake screens on all ventilators. Clean, repair, or replace the screens
to maintain equipment air flow and keep out wasps and other nest-building insects. Check the operation of ventilation fans and thermostat controls. If the vault is equipped with air conditioning, check for proper operation of system and thermostat control in warm weather months.
d. Storage. Check the vault for improper use as a storeroom. Avoid storing spare parts,
rags, etc., near high-voltage equipment. If the vault has an attached room, use this room for storing spare lamps, fuses, rags, spare parts, etc.
5.1.3 Monthly Checks.
5.1.3.1 Insulation-Resistance Test.
Performing regular preventive maintenance checks on airfield lighting circuits is absolutely necessary for reliable operation of the system. Because of the potential of operating at very high voltages, the components of the series circuit are extremely susceptible to failure.
a. Perform insulation resistance tests on all airfield circuits on a monthly basis as a
minimum. If the airport has circuits that fail regularly due to age or other reasons, consider weekly checks. Many potential failures can be found during daylight hours before they become a problem by making weekly PM insulation resistance checks a habit. Keep records in the regulator vault with the circuit identified as well as the date and results of the test. Provide space for notes as to special conditions such as weather conditions at the time of the test, recent lightning activity and to note failure locations and causes when found. A sample form is shown in Figure 5-1.
b. A single insulation resistance test (IR test) (megger test) does not present a true picture
Figure 5-1 · page 49Picture of the page from the copy saved here
of the condition of a cable’s insulation system. A single IR test provides an insulation condition assessment at that particular point in time only. For IR testing to have real value the IR testing needs to be trended over time. The trending can be used as a tool to predict cable failure allowing (preventative maintenance) replacement of failing cable to be scheduled. The values set by the FAA for initial testing and acceptance are easily obtained by the installers. Typically a high initial reading would seem to indicate a good installation.
(1) Starting with a high initial reading may sound good, but how the cable maintains
that IR value over time is the important factor. A system with a 500 megohm IR value on day 1 and a 1 megohm value on day 365, is not as good as a system with a 75 megohm value on day 1 and 25 megohm value on day 365. The downward trend is much steeper in the first example.
(2) The test voltage is not as important as the consistent application of the test
parameters. A 1,000 volt IR test is sufficient for most airfield lighting applications, provided the IR test is precisely duplicated each time, with temperature correction, to provide accurate results that can be trended.
c. Insulation resistance test sets can be purchased that are operated by hand-crank,
batteries, or on 120 volt AC supply. The battery operated sets are the most versatile. Hand-crank units are the least accurate as the operation of the instrument can vary significantly between operators. Take care in selecting a test set and potential output voltages. As a minimum, the test set should have an output of 1000 volts DC. Test sets with outputs of 2500 VDC to 5000 VDC are also available and are superior at detecting high resistance faults. It should be noted, however, that when testing older circuits,
especially circuits that normally operate at lower voltages, use of a 5000 VDC tester may show a fault in an otherwise undetected weak spot in a cable or transformer. It is therefore advisable, when testing at voltages higher than 1000 VDC, to be prepared to make immediate repairs if necessary.
(1) When performing insulation resistance tests for preventive maintenance, it is
necessary to be consistent in the way the tests are carried out from one session to the next. Test results may vary due to a number of circumstances. For instance, the test should be administered for the same length of time each time it is performed and at the same test voltage so that the results may be accurately compared.
(2) A very important consideration when performing insulation resistance tests is the
time required for the reading of insulation resistance to reach a maximum. The primary cause of delay in reaching full charge is known as the dielectric absorption effect. It may be a matter of several minutes before this is completed and for the reading to reach an absolute maximum. It is best to establish a minimum time for conducting the tests based on experience.
(3) For short time readings of insulation resistance, operate the instrument for a
definite length of time, either 30 seconds to 1 minute, and read at the end of that time. Make future tests with the same length of operating time.
(4) Other variables such as moisture, weather, and time of day may affect the readings.
Readings should ideally be taken after circuits have been de-energized for several hours. Readings may appear higher immediately after operating the circuit. This is a sign of deteriorating insulation in transformers and possibly the series lighting high voltage cable that is allowing moisture to enter. Operating the circuits raises the temperature and drives moisture from the insulation resulting in an artificially higher reading.
d. There is no ideal value for insulation resistance readings on series circuits due to factors
such as circuit length, age, etc. The best rule here is to base this decision on past experience with your own facility. Each circuit may be different based on age, manufacturer of cable and equipment, installation methods (direct buried or installed in conduit), local weather conditions, and amount of moisture normally present in the system.
e. The decision of when to consider a circuit failing and in need of preventive
maintenance repairs may vary from one circuit to another at the same facility. Generally speaking, any circuit that measures less than 1 megohm is certainly destined for rapid failure. The time it takes for a circuit to fail is affected by the output voltage of the regulator, type of fault and presence of moisture at the location of the fault. The larger the circuit size in kW, the higher the output voltage and hence, the more the condition of the insulation becomes critical.
(1) The important information is the deterioration of the resistance values from month
to month and year to year. The resistance value inevitably declines over the service life of the circuit; a 10-20 percent decline per year may be considered normal.
(2) A yearly decline of 50 percent (4 percent monthly) or greater indicates the
existence of a problem (such as a high resistance ground) or serious deterioration of the circuit insulation. In this instance the maintenance supervisor should consider performing troubleshooting to locate the problem (Chapter 6).
(3) It should also be noted that the insulation resistance that is required for new
installations will have a great effect on the ability of the maintenance staff to maintain the series lighting circuits after installation and acceptance. With newer cable installations being more frequently installed in conduit and light bases as opposed to direct burial, initial resistance values up to and in excess of 500 megohms are achievable.
5.1.3.2 Input Voltage.
Measure the input voltage to the vault. Take this measurement at various times of the day and/or night because the demand on the commercial power network varies throughout the day. Record the input voltage of each phase for future reference. If it is out of tolerance, contact the power company and have them correct the problem.
AIRPORT LIGHTING CIRCUIT INSULATION RESISTANCE TEST RECORD
VAULT OR SUBSTATION # …
CIRCUIT IDENTIFICATION …
DATE OHMS WEATHER CONDITIONS AND COMMENTS INITIALS
Figure 5-1. Sample Insulation Resistance Record
5.1.4 Semi-annual Checks.
5.1.4.1 Ground Resistance.
Perform a ground-resistance measurement for each item of equipment using a ground resistance tester. Record the readings and compare with previous readings to discover deterioration in the grounding system. The lower the resistance value, the better; a value of 5 to 10 ohms is desirable. If the resistance is greater than 25 ohms, immediate action must be taken to lower the resistance.
5.1.4.2 Primary High-Voltage Buses and Ground Buses.
Check the high-voltage bus installation with particular attention to the condition of the insulators, supports, and electrical connections. Keep the bus insulators wiped free of dust or any other deposits. Check the ground bus carefully throughout its entire length. If the bus or any ground connection to the bus is broken, make immediate repairs. De-energize the system before cleaning or repairing the bus.
5.1.4.3 Relays.
Inspect the protective relay, circuit selector switches, and auxiliary relay panels when servicing the vault equipment. Check the operation of these devices, clean the contacts, adjust release springs, and check contact arms and dash pots. Replace all unserviceable parts.
5.1.4.4 Oil Fuse Cutouts.
Check operation and electrical connections of the oil fuse cutouts. Check the contacts and check the oil level. Add oil when necessary. If fuses with replaceable links have failed, replace them with fuse links especially manufactured for this purpose. If the oil fuse cutouts have a manual operating lever, check the operation of the locking arrangement. Be sure the manual operating handle is locked in the “OFF” position before servicing vault equipment that is being supplied through the oil fuse cutout.
5.1.4.5 Oil Switches.
Check the operation of the oil switches. Be sure that the moveable handle on the oil switch, which has three positions, “MANUAL OFF,” “MANUAL ON,” and “AUTOMATIC,” is in the “AUTOMATIC” position at all times. This allows the switch to be remotely controlled. Check the contacts and oil level and service when necessary.
5.1.4.6 Power Transfer Switches.
Check operation of power transfer switches. Check contacts for dirt or corrosion.
5.1.4.7 Control Panel or Computer Control Equipment.
In some cases, an auxiliary airport lighting control panel is installed in the vault, or a computer controlled system is installed along with a monitor interface that may provide control capabilities
from the vault. In such cases, carefully check the operation of all parts of the panel. Make sure that all electrical connections are in good condition. Clean the panel with cleaning agents approved/recommended by the manufacturer. Using non-approved cleaning agents may cause smears that are difficult to remove or may damage the screen surface (especially true for low glare screens). If airport lighting control panels are computer-controlled, inspect and clean all air filters associated with the cooling fans for the computers and uninterruptible power supply units if so equipped.
5.1.4.8 Photoelectric Time Switch.
If a photoelectric time switch is installed, maintain per the manufacturer’s instructions. Check light levels with a calibrated light meter (foot candles or lux) to ensure that the control turns on and off at the proper ambient light levels.
5.1.4.9 Astronomic Time Switch.
If this switch is installed, service per according to the manufacturer’s instruction book. Inspect the operation, check clock for proper time, clean motor commutator and main switch contacts, and check all electrical connections. Because an astronomic time switch is a precision instrument, only the manufacturer or an authorized service representative should make repairs.
5.1.4.10 Radio-Control of Airport Lighting.
Check the operation of radio-controlled airport lighting by keying a portable transmitter and observing the actuation of the airport runway/taxiway lights and switching mechanism. If a fault is detected, follow the manufacturer’s recommendation for repair or replacement.
5.1.4.11 Lightning Arresters.
Check lightning arresters for burning, scorching, or other signs of failure. Inspect lightning arresters for damage after each lightning storm in the area.
5.1.4.12 Miscellaneous.