AC 150/5220-16D Automated Weather Observing Systems (AWOS) for Non-Federal Applications
This advisory circular (AC) contains the Federal Aviation Administration’s (FAA) standard for the non-Federal AWOS. This AC applies to anyone proposing to design, procure, construct, install, activate or maintain an AWOS.
This document is cancelled. It may have been replaced. Check the official source before relying on it.
Advisory
Circular
U.S. Department of Transportation
Federal Aviation Administration
Subject: AUTOMATED WEATHER OBSERVING SYSTEMS (AWOS) FOR NON-FEDERAL APPLICATIONS
Date: 04/28/2011 Initiated by: AJW-14A
AC No: 150/5220-16D Change:
1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration’s (FAA) standard for the non-Federal AWOS. This AC applies to anyone proposing to design, procure, construct, install, activate or maintain an AWOS.
2. CANCELLATION. AC 150/5220-16C, AWOS’s for Non-Federal Applications, dated 12/13/99, is canceled.
3. DEFINITION. An AWOS is a computerized system that automatically measures one or more weather parameters, analyzes the data, prepares a weather observation that consists of the parameter(s) measured, provides dissemination of the observations and broadcasts the observation to the pilot in the vicinity of the airport, typically using an integral very high frequency (VHF) radio or an existing navigational aid (NAVAID), or Automatic Terminal Information Service (ATIS). Observations may also be available by telephone dial-up service. The Non-Federal AWOS is a Non-Federal facility as defined in Appendix 1 of the latest edition of FAA Order 6700.20.
4. APPLICATION. The provisions of this AC are effective immediately for all systems, or portions thereof, that are submitted for type certification or for previously type-certified systems that are submitted for modification of their type certification certificate. The maintenance intervals and commissioning and annual revalidation criteria identified in this AC apply effective immediately to all systems that have been type certified in the past. The criteria clarifying the use of the word advisory in broadcast messages apply effective immediately to all systems that have been type certified in the past. The criteria clarifying non-Federal technician qualifications and training as well as the FAA examination and certification/verification authority issuance process apply effective immediately to anyone seeking certification/verification authority.
5. USE IN THE NATIONAL AIRSPACE (NAS). An AWOS that has been manufactured, installed, and maintained according to the criteria in this AC may constitute a National Weather Service (NWS) approved source for weather information; may be approvable as a
04/28/11 AC 150/5220-16D
ii
source of weather information that partially satisfies aviation regulations as identified in Title 14 of the Code of Federal Regulations (14 CFR); may be eligible to receive a broadcast frequency assignment or permission to broadcast over a NAVAID; may be eligible (subject to additional criteria) to transmit its weather information, directly or indirectly, to the FAA for subsequent national dissemination and may be eligible for funding under Federal grant programs.
6. CONTENT OF THIS AC. Accordingly, this AC provides guidance about the program elements that should be incorporated into an AWOS. It provides the guidance and suggestions for one method, but not the only method, of complying with all pertinent regulations.
7. PRINCIPAL CHANGES. Changes the minimum preventative maintenance interval from 90 days to tri-annual (120 days). Clarifies information about connectivity to the FAA for national dissemination of AWOS data. Changes the Office of Primary Responsibility (OPR) for type certification from the Washington DC program office to the Oklahoma City Weather Processors and Sensors Team (AJW-14A). Makes word changes to clarify sentence meanings. Changes the precipitation occurrence and measurement from one category into two distinct categories: 1) Present Weather Detector/Sensor and 2) Rain Gauge. Adds criteria for Ultrasonic Wind sensors and an AWOS to Automatic Terminal Information System (ATIS) switch.
8. HISTORICAL INFORMATION ABOUT THE PREVIOUS CHANGE DATED 12/13/99. Provided clarification as to what system performance verification testing was, why it was important to have valid performance verification checks and references, and why these checks should be accomplished at acceptable intervals. Added minimum desired and maximum operating tolerances, references, performance checks, and intervals that support reliable system performance and user confidence. Provided an incentive for manufacturers to utilize valid verification techniques and technological improvements to enhance system reliability. Redefined AWOS wind sensor tolerances to be consistent with other FAAapproved wind sensors. Clarified information about type acceptance and maintenance documentation needs. Made word changes to clarify sentence meanings.
9. REQUESTS FOR INFORMATION. Further information concerning AWOS standards and the FAA type certification approval process may be obtained from:
AWOS Non-Federal Engineering Office Weather Processors and Sensors Team (AJW-14A)
6500 S. MacArthur, Bldg 196 Oklahoma City, OK 73169 Telephone: (405) 954-8427
Brad Gee Acting Director, Safety and Operations Support
04/28/11 AC 150/5220-16D
iii
CONTENTS
Page
CHAPTER 1 . INTRODUCTION … 1
1.1. FUNCTIONAL DESCRIPTION … 1
1.2. WEATHER SENSORS … 1
1.3. OUTPUT MEDIA FOR AWOS WEATHER INFORMATION … 2
1.4. FAA’s FACILITY PERFORMANCE AND INSPECTION RESPONSIBILITY … 4
CHAPTER 2 . CERTIFICATION AND COMMISSIONING PROCESS … 7
2.1. PROCESS OVERVIEW … 7
2.2. MANUFACTURER SUBMITTALS FOR TYPE CERTIFICATION APPROVAL … 8
2.3. TEST PROGRAM … 8
2.4. SYSTEM DOCUMENTATION … 9
2.5. CONFIGURATION CONTROL PLAN … 13
2.6. PLANNING THE AWOS INSTALLATION … 14
2.7. FACILITY COMMISSIONING … 15
2.8. ON-SITE DOCUMENTATION … 16
2.9. MAINTENANCE PROGRAM … 18
2.10. ONGOING SYSTEM VALIDATION … 19
CHAPTER 3 . PERFORMANCE AND TESTING SPECIFICATIONS FOR AWOS … 23
3.1. GENERAL … 23
3.2. DEFINITIONS … 23
3.3. GENERAL PERFORMANCE STANDARDS … 24
3.4. OPERATING ENVIRONMENT … 27
3.5. MECHANICAL WINDSPEED AND DIRECTION SENSOR … 27
04/28/11 AC 150/5220-16D
iii
3.6. ULTRASONIC WIND SENSOR … 29
3.7. TEMPERATURE SENSOR … 31
3.8. HUMIDITY SENSOR … 31
3.9. DEW POINT SENSOR … 32
3.10. PRESSURE SENSOR … 34
3.11. CLOUD HEIGHT SENSOR … 36
3.12. VISIBILITY SENSOR … 43
3.13. PRECIPITATION ACCUMULATION SENSOR … 45
3.14. PRESENT WEATHER DETECTOR/SENSOR … 46
3.15. THUNDERSTORM DETECTION SENSOR OR NETWORK … 47
3.16. FREEZING RAIN OCCURRENCE SENSOR … 52
3.17. RUNWAY SURFACE CONDITION SENSOR … 53
3.18. AWOS DATA PROCESSOR … 54
3.19. OPERATOR TERMINAL (OT) … 58
3.20. VOICE SUBSYSTEM … 59
3.21. AWOS ATIS SWITCH (AAS) … 61
3.22. ELECTROMAGNETIC INTERFERENCE (EMI) PROTECTION … 62
3.23. TRANSIENT AND LIGHTNING PROTECTION … 62
CHAPTER 4 . AWOS SYSTEM MAINTENANCE AND OPERATING REQUIREMENTS … 65
4.1. INTRODUCTION … 65
4.2. SYSTEM PERFORMANCE VERIFICATION TESTING … 65
4.3. NON-FEDERAL AWOS STANDARDS, TOLERANCES, AND REFERENCES … 65
4.4. PREVENTIVE MAINTENANCE (PM) CHECKS AND SCHEDULES … 69
4.5. REQUESTING EXCEPTIONS TO MINIMUM MAINTENANCE REQUIREMENTS … 72
APPENDIX 1 . ACRONYMS USED IN THIS ADVISORY CIRCULAR … A-1
Chapter 1. INTRODUCTION › 1.2. WEATHER SENSORS.
04/28/11 AC 150/5220-16D
1
Chapter 1. INTRODUCTION
1.1. FUNCTIONAL DESCRIPTION. An AWOS automatically measures meteorological parameters, reduces and analyzes the data via computer, and broadcasts weather reports which can be received by aircraft operating up to 10,000 feet above ground level and 25 nautical miles (nm) from the AWOS. Pilots may use the certified weather information provided by the AWOS to partially fulfill the requirements of various regulations identified in Title 14 of the Code of Federal Regulations (14 CFR).
1.2. WEATHER SENSORS. The AWOS is a modular system utilizing a central processor which may receive input from several sensors. Five standard types of AWOS are defined in the following paragraphs a through e; however, an AWOS may be type certified with any combination of sensors. These five standard types are used throughout this AC and are recognized in other FAA Orders.
a. AWOS A. The AWOS A system measures and reports altimeter only.
b. AWOS I. The AWOS I system measures and reports wind data, e.g., speed, direction, and gusts; temperature; dew point; altimeter; and density altitude.
c. AWOS II. The AWOS II system measures and reports all the parameters of AWOS I system plus visibility.
d. AWOS III. The AWOS III system measures and reports all the parameters of AWOS II system plus precipitation accumulation (rain gauge) and cloud height. AWOS III can have optional sensors such as precipitation type/intensity (present weather, P) and/or thunderstorm/lightning (T). The addition of an optional sensor will change the designation to AWOS III P or AWOS III T, or AWOS III P/T.
e. AWOS IV. The AWOS IV system measures and reports all the AWOS III P/T (i.e. AWOS III with both present weather and thunderstorm/lightning) parameters plus freezing rain (Z) and/or runway surface condition (R). The addition of an optional sensor will change the designation to AWOS IV Z, AWOS IV R, or AWOS IV Z/R.
f. Any standard type certified AWOS may include additional sensors to suit individual airport needs. (For example, the AWOS AV consists of an AWOS A with a visibility sensor.) If the additional sensors are to be considered certified, they must meet the certification criteria of this AC and be installed, commissioned, inspected and maintained in accordance with this AC. All other sensors are considered advisory. Advisory sensors may not meet the criteria of this AC, may not be installed, maintained, or inspected in accordance with this AC and are not approved sources of weather information. Any advisory sensor values and parameters relying on an advisory sensor’s
Chapter 1. INTRODUCTION › 1.3. OUTPUT MEDIA FOR AWOS WEATHER INFORMATION.
04/28/11 AC 150/5220-16D
2
values must be differentiated from certified parameters by being clearly identified as such and preceded by the word advisory in the voiced message. Any information preceded by the word advisory, regardless of its source, is considered advisory. When broadcast via radio or telephone, official weather information should be broadcast first, followed by the word advisory and then followed by all remaining weather information that is not from an approved weather source. Advisory information cannot be included in any portion of the outgoing METAR message.
1.3. OUTPUT MEDIA FOR AWOS WEATHER INFORMATION.
a. The output of the AWOS is reported by a computer-generated voice, which is transmitted to pilots over a discrete VHF transmitter or the voice output of a Navigational Aid (NAVAID). The transmission may be continuous or may be triggered by three clicks of a pilot's microphone on the AWOS broadcast frequency if the AWOS broadcasts over a VHF aeronautical advisory station frequency radio, e.g., UNICOM. System design may permit the transmission of the identification of a NAVAID by using the AWOS voice capability. In all cases where the voice output of a navigational aid is used, provision should be made so that the failure of an AWOS would in no way result in any failure of the NAVAID being used.
b. AWOS messages may be offered via other formats that the owner chooses to provide, including telephone dial-up service. An option allows type certified, commissioned AWOS III and AWOS IV data to be disseminated by the FAA nationally so that the weather information is available for forecasting and flight planning purposes. The connection type can be via an approved third party vendor or the state approved interface, e.g. the National Association of State Aviation Officials (NASAO), who provides the connection to the Weather Message Switching Center Replacement (WMSCR) for type certified, commissioned AWOS III or IV systems by the means of file transfer protocol (ftp). To contribute to this network, the AWOS should provide the data in a format that is compatible with the approved third party vendor or the state approved interface. The third party vendor or the state is responsible for all coordination with the WMSCR office.
c. The third party vendor or state agency that provides non-Federal AWOS weather information to the FAA for national dissemination would be required to sign a Memorandum of Understanding (MOU) with the WMSCR office that commits them:
(1) To convert the AWOS data to the current or future WMSCR format interface.
(2) To the current METAR format.
(3) To a reporting frequency, e.g., number of reports per hour, in accordance with criteria directed by the WMSCR office within the FAA.
04/28/11 AC 150/5220-16D
3
(4) To bear all communications, quality assurance, troubleshooting, and administrative costs to provide their non-Federal AWOS information to the WMSCR.
(5) To provide a point of contact for use by the FAA and others to report problems with the AWOS or with the communications link to the WMSCR. The point of contact would be available by telephone and responsive during normal business hours, and is encouraged to be responsive on a 24-hour a day basis.
d. The output of the AWOS weather observation is controlled by one of four modes of operation. Mode 1 is applicable to all systems; modes 2, 3, and 4 are applicable only to systems configured with an operator terminal (OT). Modes 3 and 4 require an agreement with the NWS to maintain a Non-Federal Observer (NF Obs) program to augment and backup the AWOS system.
(1) Mode 1, Full-time Automated Operation. In this mode, the AWOS operates 24 hours/day without any manual input. The automated weather observations are updated on a minuteby-minute basis. There is no weather observer input to the AWOS. However, a manual observing capability may be maintained as backup provided that an agreement exists with the National Weather Service (NWS) to maintain a manual observing capability such as Supplemental Aviation Weather Reporting Service (SAWRS).
(2) Mode 2, Full-time Automated Operation with Local Notice to Airmen (NOTAM). Operation in this mode is the same as Mode 1, with the addition of the capability to append a manually recorded NOTAM to the automated voice reports (see paragraphs 3.19.a.(1)(d) and 3.20. The airport manager is responsible for the timeliness and accuracy of the NOTAM information. This NOTAM is limited to aviation related information specific to the airport in accordance with the latest edition of FAA Order 7930.2, Notice to Airmen (NOTAM), and must not include commercial announcements such as fuel prices, lodging, etc. NOTAM information is heard on the local voice broadcast, it is not transmitted over the national network. There is no weather observer input.
(3) Mode 3, Full-time Automated Operation with Manual Weather Augmentation and Local NOTAM Option. Operation in this mode is the same as Mode 1 with the addition of the capability for a NWS certified weather observer to manually augment the automated observation by appending a weather entry to the observation during the weather observer duty hours. The observer duty hours should be published in the Airport/Facility Directory. The addition of a local NOTAM, per paragraph 1.3.c.(2), is also permitted in this mode of operation, provided there is no interference with the observer augmentation. The weather observer is responsible for the accuracy and timeliness of the added weather information. The weather to be added is limited to thunderstorms, all types of precipitation, and obstructions to vision. The weather parameters added by the observer is to be manually recorded and appended to the automated voice reports using the operator terminal (OT) and, as applicable, entered manually into the system for transmission over the national network. The procedures in the latest edition of the Federal Meteorological Handbook No. 1 (FMH-1), and the latest edition of FAA Order 7900.5, Surface Weather Observing, apply.
Chapter 1. INTRODUCTION › 1.4. FAA’s FACILITY PERFORMANCE AND INSPECTION RESPONSIBILITY.
04/28/11 AC 150/5220-16D
4
(4) Mode 4, Part-time Manual Operation. Mode 4 is normally used for backup. This mode permits a NWS certified weather observer to enter a complete manual observation into the system. The procedures in the latest editions of FMH-1 and Order 7900.5 apply to the recording and formatting of these manual observations. As applicable, the manual observations are transmitted to the national network. Voice dissemination of the observations should be done manually using the OT. The manual observations include input from the automated AWOS outputs available to the weather observer on the OT display, to be modified in accordance with the latest edition of FAA Order 7900.5. For example, the manual observation includes manually derived ceiling/sky condition and visibility, using FMH-1 definitions, which differ somewhat from the AWOS algorithms. Temperature, dew point, wind direction/speed, and altimeter setting are the same and are used exactly as presented on the AWOS OT display or using FAA approved back-up instrumentation.
e. Aviation Routine Weather Report Format (METAR).
(1) All AWOS output must meet METAR format requirements. National network distribution of wind direction must be in True while local dissemination, e.g., radio and telephone, must be Magnetic.
(2) A current copy of the appropriate interface control document (ICD) can be obtained from the AWOS Non-Federal Engineering Office at the following address.
AWOS Non-Federal Engineering Office Weather Processors and Sensors Team (AJW-14A)
6500 S. MacArthur, Bldg 196 Oklahoma City, OK 73169 Telephone: (405) 954-8427.
1.4. FAA’s FACILITY PERFORMANCE AND INSPECTION RESPONSIBILITY. The General Aviation Revitalization Act of 1994 reaffirmed the FAA’s responsibility and authority to regulate and inspect air navigation facilities, including aviation meteorological services. The establishment and maintenance of non-Federal facilities, including AWOS systems, are covered in the latest edition of FAA Order 6700.20, Non-Federal Navigational Aids and Air Traffic Control Facilities.
a. Chapters 3 and 4 of this AC provide the FAA’s minimum acceptable commissioning and revalidation standards and references for a non-Federal AWOS system. Chapter 4 also provides the expected minimum checks and maximum maintenance intervals between checks.
04/28/11 AC 150/5220-16D
5
b. FAA-owned meteorological/AWOS equipment tolerances are found in the latest edition of FAA Order 6560.13, Maintenance of Aviation Meteorological Systems.
c. Non-Federal AWOS systems require on-site commissioning. In accordance with the latest edition of FAA order 6700.20, commissioning is required to be accomplished on-site by a qualified technician with the proper FAA verification authority and witnessed by a qualified FAA non-Federal inspector.
d. Non-Federal AWOS systems require annual on-site performance verification. In accordance with the latest edition of FAA Order 6700.20, this verification is required to be accomplished on-site by a qualified technician with the proper FAA verification authority and witnessed by a qualified FAA non-Federal inspector.
e. Verification is the written assurance that the facility, system, or service is providing the required/advertised service to the user. System performance checks are made to identify and correct changes or drifting of performance parameters and to provide documented assurance to the user of the validity of the published information.
f. If results of these checks are satisfactory, a maintenance technician with FAA verification authority will document this fact by making a system verification entry in the facility’s FAA Form 6030-1, Facility Maintenance Log. If the checks are not satisfactory, the maintenance technician should make an appropriate entry in the Facility Maintenance Log and the system or individual sensor should not be used. (Maintenance logs should be retained on-site.) In addition, if the sensor affects the altimeter reading, the entire AWOS is to be removed from service and a NOTAM issued to document the system status. For any other sensor, the sensor is to be NOTAMed as unreliable or out of service. For guidance on Facility Maintenance Log entries, reference 300-PML, Paper Maintenance Log, and the latest edition of FAA Order 6040.15, National Airspace Performance Reporting Systems (NAPRS).
04/28/11 AC 150/5220-16D
6
[This page intentionally left blank.]
Chapter 2. CERTIFICATION AND COMMISSIONING PROCESS › 2.1. PROCESS OVERVIEW.
04/28/11 AC 150/5220-16D
7
Chapter 2. CERTIFICATION AND COMMISSIONING PROCESS
2.1. PROCESS OVERVIEW. In order to provide confidence in the quality of the meteorological data that the AWOS provides to users in the aviation community, the FAA has initiated a three-part AWOS quality assurance process consisting of type certification, site-specific commissioning and annual revalidation.
a. Type Certification. The manufacturer should provide the FAA with the test data and other system documentation to demonstrate that the AWOS system meets the criteria of this AC. Reference paragraph 2.2, Manufacturers Submittals for Type Certification Approval. Upon completion of all the requirements set forth in this AC, the FAA will grant type certification approval to the specific system configuration documented in the request.
b. Site-Specific Approval. Prospective sponsors, i.e., owners, wanting to install an AWOS system for public use should closely coordinate their plans with the FAA Service Center non-Federal Program Implementation Manager (PIM) or coordinator and follow the procedures provided. The latest edition of FAA Order 6700.20 requires that a Memorandum of Agreement (MOA) and an Operations and Maintenance Manual (OMM) be established between the sponsor and the FAA and agreed to, i.e., signed, prior to commissioning the AWOS for public use. The MOA/OMM is used to ensure that there is a mutual understanding of what is required to operate and maintain a commissioned AWOS system. After the AWOS is installed on-site, and the MOA/OMM is signed, the FAA conducts a commissioning ground inspection to verify that the system is located, installed and operating correctly and that the owner has the resources to maintain the system in proper operating condition. Reference paragraph 2.7 for information on facility commissioning. A flight inspection is required for NAVAIDS used for AWOS VHF dissemination. This process should be successfully completed for the AWOS to be commissioned by the FAA and to be authorized to operate.
c. FAA Inspections. Finally, in addition to the annual revalidation inspection, there may be periodic visits to the operational AWOS by the FAA and other technical representatives to verify that the system continues to operate correctly. Guidance for these visits may be found in paragraph 2.10, Ongoing System Validation, and Chapter 4, AWOS System Maintenance and Operating Requirements, of this AC, the facility MOA/OMM, and the latest edition of FAA Order 6700.20.
Chapter 2. CERTIFICATION AND COMMISSIONING PROCESS › c. Product approval (including type certification, commissioning, or…
04/28/11 AC 150/5220-16D
8
2.2. MANUFACTURER SUBMITTALS FOR TYPE CERTIFICATION APPROVAL.
a. The AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2) will grant type certification approval to an AWOS design after review and approval of three submittals from the manufacturer.
(1) The first submittal consists of test procedures and data sheets that demonstrate that the proposed AWOS configuration meets the criteria of this AC. This submittal should include a single matrix showing each specific requirement from this AC, cross-referenced to the specific location, e.g., paragraph, page, etc., within the manufacturer’s submittal where the requirement has been addressed.
(2) The second submittal consists of warranty, training, and maintenance documents intended to support the AWOS system owner.
(3) The third submittal consists of a configuration control plan that identifies the components and options approved for use with the system.
b. Requests for type certification approval should be sent to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2).
c. Product approval (including type certification, commissioning, or annual revalidation) may be revoked or an individual site may be removed from service if:
(1) The equipment is not maintained or inspected in accordance with this AC.
(2) The equipment has an unacceptable failure rate.
(3) There is a deficiency that precludes or hampers valid performance verification of the system operation.
(4) Changes are made to the software, firmware or hardware without FAA approval.
(5) Transmitted data does not conform to the latest editions of the Federal Meteorological Handbook (FMH-1) or FAA Order 7900.5.
(6) The manufacturer fails to honor the warranty.
2.3. TEST PROGRAM. Chapter 3 of this AC contains the performance and testing standards for each component of the AWOS. The manufacturer should demonstrate compliance with these
04/28/11 AC 150/5220-16D
9
standards through performance testing where a test is specified or by analysis and inspection. The manufacturer provides all necessary equipment and bears all testing costs. Prior to performing tests the manufacturer should propose a test plan to the FAA containing detailed procedures for conducting the tests, as well as the name and location of the facility where the tests are to be conducted. Prior FAA review of the test plan should minimize the likelihood of improper test procedures that might result in rejection of the data. It is the responsibility of the manufacturer to provide credible test data to the FAA that is based on fact and representative of the equipment being type certified. Submissions should include all data collected during a test; data should not be omitted because it falls outside of the recommended acceptable limits of this AC. After completion of the tests, the manufacturer should reduce the data to an easily understood format to demonstrate conformity with this AC. If the manufacturer has previously performed testing, the test procedures and data sheets from these tests may be submitted for consideration. However, the FAA reserves the right to witness testing, request additional testing, and examine raw data.
2.4. SYSTEM DOCUMENTATION.
a. The manufacturer should submit one hard copy and one permanent media (CD, DVD or similar) electronic copy of the draft documentation described in this paragraph to the AWOS Non- Federal Engineering Office at the address provided in paragraph 1.3.e.(2) for review and approval. The System Description Manual, Maintenance Manual, Installation and Checkout Manual, Operating Instructions Manual, applicable schematics, and Annual System Revalidation Plan Manual should be provided as separate manuals. These documents are intended to assist the AWOS owner in the installation, operation, and maintenance of the system. The items may be cross-referenced to avoid duplication, but the elements of each portion of each document should be clear. For example, the maintenance procedures that are performed during the annual system revalidation should be explicitly referenced.
b. After the FAA has approved these manuals, five permanent media (CD, DVD or similar) electronic copies and five hard copies of these approved documents should be submitted to the FAA as follows:
(1) One electronic copy and one hard copy to:
AWOS Non-Federal Engineering Office Weather Processors and Sensors Team (AJW-14A)
6500 S. MacArthur, Bldg 196 Oklahoma City, OK 73125
04/28/11 AC 150/5220-16D
10
(2) Four electronic copies and four hard copies to:
Non-Federal AWOS Program (AJW-163)
Orville Wright Bldg. (FOB10A)
800 Independence Ave., SW Washington, DC 20591
c. The following documents must be submitted to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2) and approved before type certification approval of any system or any system modification requiring a change in any of these documents will be granted. These documents are distributed to each FAA service area and other appropriate FAA offices to keep them apprised of all type certified systems, sensors, and changes. If a manufacturer modifies the initially approved configuration, the submission process must be repeated before type certification approval is granted for the modified system, and the system is offered for sale.
(1) System Description. The system description document should identify and catalog the hardware components to the level of the smallest field-replaceable unit (FRU) module and should describe system software and firmware. The principles of system operation should be described using schematics, block diagrams, flow diagrams and pseudocode as appropriate. Sensor processing should be described using pseudocode. For peripheral devices, the performance parameters should be included along with the name and address of the original manufacturer.
(2) Manufacturer's Maintenance Manual. The manufacturer's maintenance manual should contain a comprehensive maintenance program to be implemented by the owner to ensure reliable and accurate performance over the life of the system. As a minimum, the program should define all maintenance activities that are required within a period of 5 years and a recommended frequency, e.g., tri-annually, i.e. three times per year, annually for each operation. The following topics should be addressed in the Maintenance Manual.
(a) Maintenance Procedures. The maintenance procedures manual should contain a step-by-step procedure for each scheduled, i.e., periodic, and unscheduled, i.e., repair, maintenance operation. It should discuss calibration methods including the importance of using collocated National Institute Standards & Technology (NIST) traceable calibrated test equipment; troubleshooting procedures; suggested spare parts; and identify all test equipment required. This document should also include the detailed procedures, e.g., the keystrokes, the maintenance technician follows when using the operator terminal to perform maintenance on the system.
(b) System Performance Parameters. The system performance parameters manual should contain a complete listing of the test points, sensor outputs, waveforms, and other parameters which indicate system performance that may be measured in the field as described in Chapter 4. If
04/28/11 AC 150/5220-16D
11
these quantities are field adjustable, then an initial value for use during initial commissioning certification and an operating tolerance for use during the annual verification should be given. The key system parameters should also be identified; i.e., those values which best indicate system performance and to be checked most frequently. The frequency of scheduled maintenance action, e.g., tri-annually and annually, should also be given.
(c) Data Recording Forms. This manual should contain three types of forms designed to aid the system owner in recording the system performance data described in paragraph 2.4.b.
(i) The Comprehensive Facility Performance and Adjustment Data Form. This form is similar to FAA Form 6030-17, Technical Reference Data Record, and is an initial facility commissioning data form which should be completed at system commissioning and after major repair work, i.e., after a major component has been replaced. The form should contain the standards and tolerances of each component, all of the initial commissioning checks required, space to record the actual result of each performance check, and another space to enter the standard or reference value expected from each check.
(ii) The Technical Performance Record (TPR). The TPR is similar to FAA Form 6000-8, Technical Performance Record, and is a data record form that is used to record the results of performance checks accomplished during routine and non-routine maintenance visits. It may also be used as a checklist of all of the scheduled maintenance to be done at the facility during a specific routine scheduled maintenance (SM) visit, e.g., during a visit to accomplish scheduled tri-annual or annual performance maintenance (PM). The form should also include the standards and tolerances required to be measured with a space to record each result. It is to be used to record the actions during the tri-annual maintenance visit, the annual validation inspection, during non-routine maintenance performed to capture any changes to sensor or system parameters, and to log the results of tests conducted after an aviation accident. Separate forms may be established and used to cover different PM visits.
(iii) FAA Form 6030-1. The third form is the FAA Form 6030-1, Facility Maintenance Log. The FAA will provide this form. Instructions for its use should be included in the FAA/sponsor MOA/OMM. The maintenance log should be retained on site. All site visits should be documented on this form. It will provide a historical record of all maintenance actions accomplished on the AWOS. The technician should list all maintenance actions accomplished, e.g., tri-annual scheduled maintenance actions completed, dew point sensor replaced; any damage should be logged, e.g., bullet hole in vertical fin of the wind sensor, needs replacement; and any problem with the AWOS should be noted, e.g., dew point sensor disconnected, replacement required. When a system or component repair or adjustment has been accomplished, the maintenance technician should make a performance verification statement on this form. In all cases, the technician completing the action and making the form entry should be identified on the form. These forms also contain the date of the action, the facility name and location, and other identifying data. More information on completion of the Form 6030-1 may be found in the MOA/OMM or the latest edition of FAA Order 6700.20.
04/28/11 AC 150/5220-16D
12
d. Installation and Checkout Manual. This document should thoroughly describe the installation and checkout procedures to be followed by the technician at the installation site.
e. Operating Instructions (i.e., an Observer Handbook). This document should provide detailed instructions for a National Weather Service (NWS) certified weather observer to operate the system. This document should describe and provide instructions for operation in each of the four modes described in see paragraph 1.3.d, and it should explain the procedures when using the operator terminal to augment or to backup the AWOS, or to disseminate NOTAM information.
f. Training Program. The training program should consist of a summary of the knowledge and skills that a maintenance technician should possess to service the AWOS. This document should also propose a program to familiarize maintenance technicians with the maintenance and operation of the AWOS. The training program may be conducted on-site, at the factory, via home study, or by other means suggested by the manufacturer to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2) for approval by the FAA. The training program should cover both concepts and practical performance. It should contain a written test that may be used to measure a person’s knowledge of the system. The manufacturer should submit to the AWOS Non- Federal Engineering Office at the address provided in paragraph 1.3.e.(2) two equivalent, comprehensive 50-question open book tests with answer sheets for approval. The two tests will be used interchangeably by the FAA to test the competence of a maintenance technician on the specific system. The FAA will administer the performance examination to any technician seeking verification authority on the specific system. This exam will require the technician to demonstrate the ability to accomplish all commissioning and annual reverification tasks.
g. Annual System Revalidation Plan. This plan should contain the recommended procedures to conduct an annual inspection of the facility to revalidate the system and document that it is in the approved configuration and operating within tolerance. Reference paragraph 2.10 for information on system revalidation.
h. Warranty. The manufacturer should submit to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2) a statement certifying the following minimum warranty for the equipment:
This equipment has been manufactured and should perform in accordance with requirements of this AC. Any defect in design, materials, or workmanship which may occur during proper and normal use during a period of 1 year from date of installation or a maximum of 2 years from date of shipment should be corrected by repair or replacement by the manufacturer.
04/28/11 AC 150/5220-16D
13
2.5. CONFIGURATION CONTROL PLAN. Due to the modular nature of the AWOS, many system components such as sensors and peripheral devices may be interchangeable. Since type certification approval is given only to specific combinations of components, the manufacturer should establish a configuration control mechanism that would uniquely identify each FAA-approved system, its hardware, software and firmware components (including revision levels) and its documentation (including revision levels). Before type certification approval is granted, the manufacturer should submit a Configuration Control Plan to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2) for approval.. The configuration control plan should explain and include the procedures for configuration control of all hardware, software, firmware and documentation. The identifying information for each system should be permanently inscribed on a system name plate.
Changes to an approved configuration should be submitted for FAA approval to the AWOS Non-Federal Engineering Office at the address provided in paragraph 1.3.e.(2). The manufacturer may incorporate minor product improvement changes after notifying and obtaining approval from the FAA AWOS Non-Federal Engineering Office. Major changes, such as a sensor or a major hardware, software or firmware change should be fully supported by documentation and appropriate test data. Major changes normally require the assignment of a new configuration number. The FAA will determine the scope of the change, i.e., major vs. minor. Every change to an approved AWOS should be supported by revised configuration controlled documentation. The plan should also address:
a. The manufacturer's arrangement for assigning a configuration identification number/symbol/etc., and the means used to identify which system components, e.g., hardware, software, firmware and documentation, are included in a particular system configuration.
b. Procedures for notifying system owners of changes in the approved configuration of their AWOS.
c. Procedures for identifying and maintaining a record of the configuration of each operational system that has been sold by the manufacturer.
d. Procedures for the configuration control of documentation, to include procedures for issuing changes, numbering, and dating pages.
04/28/11 AC 150/5220-16D
14
2.6. PLANNING THE AWOS INSTALLATION.
a. All airport owners, sponsors, or other parties contemplating purchase and installation of a non-Federal AWOS should coordinate with the FAA before the equipment is ordered. The FAA Service Center non-Federal PIM is the official FAA point of contact in the Service Center Planning and Requirements Group and is responsible for the overall project coordination between the sponsor and other elements in the FAA. Airport sponsors desiring to obtain a grant under the Airport Improvement Program (AIP) to install an AWOS should also coordinate with the FAA Airport District Office that has jurisdiction over its specific geographical area. The FAA non-Federal Program Implementation Manager should coordinate the proposal with the Flight Procedures Office, Operations Support Group, Frequency Management Office, Airport District Office and other FAA offices as needed.
b. The selection of a voice outlet frequency for the AWOS is a critical issue. Therefore, it is advisable to coordinate with the FCC in the early planning stages of the facility, since there are a limited number of frequencies available for this purpose. (In accordance with the latest edition of FAA Order 90-42, Multicom frequencies are not intended for automated weather broadcasts.) The following order of frequency priority has been established by the FAA and should be used to the extent possible in establishing AWOS ground-to-air communications outlets.
(1) Assigned Automatic Terminal Information Service (ATIS) Frequency. At part-time towered locations, the AWOS utilizes the existing ATIS voice outlet frequency to provide weather information when the tower is closed. Frequency sharing coordination is discussed further in paragraph 3.21, AWOS ATIS Switch (AAS).
(2) VHF omnidirectional radio range (VOR) or VHF omnidirectional radio range/tactical air navigation (VORTAC) except Doppler VOR, with voice capability.
(3) The VOR/VORTAC must be located within 3 nautical miles (nm) of the airport and must not be used to broadcast other information such as Enroute Flight Advisory Service (EFAS).
(4) Nondirectional Radio Beacon (NDB) With Voice Capability. The NDB must be located within 3 nm of the airport. At locations where frequency congestion in the VHF air-ground band is not expected to be a problem, the use of an NDB should be considered as the fourth priority. The NDB frequency may have to be changed if the existing frequency is not in the 325 to 415 kilohertz (kHz) range.
(5) Any 25 kHz spaced discrete VHF air-ground communications channel in the air traffic control band (118-137 MHz). If an airport is equipped with an NDB or VOR/VORTAC, a request for a discrete frequency assignment should include a justification statement as to why it is not used for the AWOS transmission.
04/28/11 AC 150/5220-16D
15
c. The service volume for an AWOS voice outlet, excluding those broadcasts over existing ATIS systems, is normally limited to 10,000 feet above ground level and 25 nm from the AWOS. The FCC should approve requirements in excess of this value. Under no circumstances should the radius of the service volume exceed the terminal control area.
d. If the AWOS system proposed for installation does not meet the requirements of this AC or the radio does not meet the requirements of the FCC-approved standards, the FCC may not assign a broadcast frequency.
e. After an AWOS III or IV has been granted type certification approval and commissioned by the FAA, it becomes the weather source for the airport. Any existing manual weather observation program whose hours conflict with the AWOS III or IV should be terminated. However, as specified in paragraph 1.3.d, the AWOS owner may elect to maintain a manual observation capability to back up the AWOS in the event the system, or any critical parameter, e.g., windspeed/direction, ceiling/sky condition, visibility, altimeter setting, fails. In addition, the AWOS owner may elect to augment the AWOS output with observed parameters, e.g., thunderstorms or precipitation that are not within the capability of the AWOS. In these cases, the supplementary aviation weather reporting station (SAWRS) agreement with the NWS should be amended accordingly.
2.7. FACILITY COMMISSIONING. The FAA should formally commission the AWOS facility before it becomes available for public use. After receiving approval of a broadcast frequency, the owner may procure and install the AWOS facility. At least 120 days prior to the anticipated commissioning date, the owner should notify the FAA Flight Procedures Office (FPO) so that routine revisions may be made to the instrument approach procedures. As the system approaches operational readiness, the owner should request a commissioning ground inspection by an FAA non- Federal inspector. This inspection should include participation by the owner or owner's maintenance representative. The commissioning inspection consists of the tests and checks identified in the following paragraphs, a review of the operations and maintenance documents on file at the facility, and the recording of the initial facility performance data which should be retained as commissioning documentation in the Facility Reference Data (FRD), or similar historic record locations.
a. Siting, Installation, and Commissioning.
(1) Siting. FAA form 7460-1, Notice of Proposed Construction or Alteration, must be filed on line through www.faa.gov for approval of the proposed AWOS location. This location should be in accordance with the siting criteria contained in the latest edition of FAA Order 6560.20, Siting Criteria for Automated Weather Observing Systems (AWOS). Following installation, the FAA Tech Ops District non-Federal inspector should also verify that the AWOS equipment is installed in accordance with the siting order and that the checkout procedures have been performed. Any exceptions to the siting order should be justified and documented in the OMM as being the best
04/28/11 AC 150/5220-16D
16
practical solution for meeting the intent of the siting criteria. Any discrepancies found during the inspection should be rectified before the facility can be commissioned.
(2) Installation. The AWOS is a permanent facility and is located, constructed, and installed in accordance with applicable code requirements. It should be installed by a technician who is fully qualified in electronic applications; has a working knowledge of the operation, testing, and maintenance of the AWOS; and is either a maintenance technician employed at the manufacturer's factory or has been certified by the FAA. The procedures in the FAA-approved Installation and Checkout Manual should be performed. Reference paragraph 2.4.d for a description of the manual.
(3) Commissioning. Once the AWOS has been properly installed in accordance with the siting criteria and demonstrates that it meets the criteria established by this AC, it is commissioned to operate in the National Airspace System (NAS).
b. Performance Test. The AWOS owner’s FAA-approved maintenance representative should operate the system and measure all system performance parameters described in this AC and the manufacturer’s Maintenance Manual. The initial commissioning data are witnessed by the FAA Non-Federal Inspector and recorded on Comprehensive Facility Performance and Adjustment Data forms, or other approved commissioning data forms and retained at the facility in the FRD as commissioning documentation.
c. Flight Inspection. All NAVAID facilities, e.g., VOR, NDB, used as a voice outlet to broadcast weather information should be flight inspected to assure that operation of the NAVAID has not been derogated. If, during flight inspection, it is determined that performance of the NAVAID has been affected, the AWOS should not be activated until the malfunction has been corrected, e.g., through modification or by employing a separate discrete frequency transmitter to broadcast the weather. An AWOS utilizing a discrete frequency transmitter is not required to undergo a flight inspection.
d. Notification of the Commissioning. Following successful completion of the commissioning inspection, the FAA non-Federal PIM should notify the necessary FAA Offices, e.g., NFDC, FPO, MOCC, national non-Federal office, etc., of the commissioning date, broadcast frequency, voice access telephone number, system owner, and maintenance arrangements.
e. Relocation of an AWOS. In the event that an AWOS is removed from service to be relocated, a decommissioning NOTAM should be issued, instead of a facility out-of-service NOTAM. After relocation, a complete facility commissioning inspection should be performed.
2.8. ON-SITE DOCUMENTATION. The following documentation should be kept and maintained at the AWOS facility. It should contain all pertinent up to date on-site documentation, including the
04/28/11 AC 150/5220-16D
17
following documentation. The FAA should review the documentation at the commissioning inspection and during annual revalidation.
a. Type Certification Approval. A copy of the FAA letter to the manufacturer granting type certification approval for the AWOS system design should be included. The subsystems should be inspected to verify that the installed AWOS configuration is consistent with the type certification approval that was given.
b. Frequency Allocation Approval. A copy of the frequency FCC station license that was obtained assigning the approved operating UHF and VHF frequencies if appropriate.
c. Manufacturer's Documentation. Copies of the AWOS operating instructions, manufacturer’s Maintenance Manual, and System Description. When changes are made to the manufacturer’s documents, the manufacturer should forward revisions to the AWOS owner who is responsible for inserting them into the appropriate on site documentation.
d. Operational Procedures. Site-specific operational procedures that set forth mandatory site procedures for both routine and nonscheduled situations should be kept at the AWOS site. These procedures may incorporate appropriate sections of the manufacturer's manuals. The following items should be covered.
(1) Physical security of the facility.
(2) Maintenance and operations by authorized persons, including who to notify if a weather parameter is discovered out of tolerance or other maintenance is necessary.
(3) Posting of licenses and signs.
(4) Notice to the FAA PIM or coordinator/inspector must be made when any AWOS service has been suspended, or when a critical weather parameter is out of tolerance.
(5) Keeping of station logs and other technical reports.
(6) Names, addresses, and telephone numbers of persons to be notified in the event of system failure.
(7) Procedures for periodic scheduled shutdown maintenance, including the office responsible for generating NOTAMs for routine or nonscheduled shutdowns.
(8) Procedures for amending or revising the site instructions.
04/28/11 AC 150/5220-16D
18
(9) Procedures to be followed to freeze the 96 hours worth of AWOS data that were gathered prior to the time of an aircraft accident or incident, and the procedures to be followed to retrieve these data files for off-line analysis. These procedures should describe the responsibility for accomplishing these actions. They should be accomplished immediately following an accident, incident, or upon the request of a member of the FAA or NTSB.
(10) Locations of AWOS components on the airport. This includes the result of the survey to establish the site elevation, the elevation of the barometric pressure sensors and a true North reference point.
(11) Copy of all software and firmware licenses with revision identification.
(12) A MOA signed by the owner and the FAA Service Area Technical Operations Director or designee. This memorandum should state that the owner agrees to maintain, repair, and modify the AWOS in accordance with the requirements, standards, or criteria governing AWOS, particularly those contained or defined in the agreed to FAA/Owner OMM. The owner understands that noncompliance with the specific site’s FAA/Owner MOA/OMM may result in the AWOS’s removal from service or decommissioning.
(13) A copy of any agreement with the NWS to maintain a SAWRS capability to augment or back up the AWOS.
e. Commissioning Documentation. The initial commissioning documentation form such as the Comprehensive Facility Performance and Adjustment Data form should be completed during commissioning to record initial values and the respective standard or reference values as described in Chapter 4.
2.9. MAINTENANCE PROGRAM. The maintenance program should cover a minimum period of 5 years as established in paragraph 2.4.c.(2), and should consist of properly trained personnel meeting all FCC and FAA requirements, adequate test equipment, and resources to fulfill the manufacturer's recommended scheduled maintenance and calibration procedures as defined in the manufacturer's Maintenance Manual. The maintenance program is the responsibility of the owner, but may only be performed by personnel meeting vendor specific, FAA and FCC requirements. A person meeting these maintenance requirements will be issued an FAA verification authority letter for the specific vendor’s system.
a. Maintenance Personnel. The owner should show that the maintenance program adopted has qualified personnel available to maintain the AWOS system. The latest edition of FAA Order 6700.20, Non-Federal Navigational Aids and Air Traffic Control Facilities, contains the qualifications for maintenance technicians that maintain non-Federal facilities. They should have the
04/28/11 AC 150/5220-16D
19
special knowledge and skills needed to maintain the AWOS facility and should have completed the manufacturer's training program or the FAA-approved Concepts Bypass exam. They should be able to demonstrate proficiency in accomplishing the required maintenance procedures including validation of test equipment calibration, and using the specialized test equipment. The FAA will issue a vendor specific verification authority letter to the candidate maintenance person if he/she is able to meet the concepts and performance requirements of the AWOS system, and has a FCC general radiotelephone license for maintenance of the associated transmitter, discrete frequency (UHF or VHF) or aeronautical advisory station (Unicom).
b. Test Equipment. The owner should have available at the facility, at the time of commissioning, all test equipment required by the approved maintenance plan for maintenance and calibration of the facility. Test equipment must be capable of accurately measuring the appropriate performance parameters to verify technical standards and tolerances needed for facility verification, and must be collocated with the AWOS. Test equipment should be calibrated to NIST traceable standards in accordance with the calibration schedule submitted to and approved by the AWOS Non- Federal Engineering Office at the address provided in paragraph 1.3.e.(2) during type certification acceptance. In case an acceptable test equipment calibration schedule was not included, test equipment will be calibrated as per the test equipment manufacturer’s recommendations. Test equipment calibration should be traceable to national standards, and proof of calibration, e.g., a current calibration sticker should accompany each piece of test equipment when it is being used. The test equipment should be available when required for commissioning, scheduled system maintenance and calibration, or for repairs following system failure. All measurements should be made with test equipment collocated with the AWOS equipment being measured.
c. Annual Performance/Configuration Revalidation. The owner should plan for complying with the manufacturer's recommended and FAA approved plan for annual system revalidation. This plan should identify the appropriate FAA Tech Ops Non-Federal District Office to notify to witness the on-site revalidation and include a list of the procedures to be followed during the on-site revalidation as well as the source of the FAA qualified non-Federal technician to perform the inspection.
2.10. ONGOING SYSTEM VALIDATION. To verify that the system is being properly maintained and that the system retains an approved configuration, the following ongoing validation program should be conducted.
a. Performance/Configuration Revalidation. An FAA Service Area non-Federal coordinator or inspector should perform an on-site verification inspection of each AWOS annually in accordance with the manufacturer's approved Annual System Revalidation Plan. This inspection should include the items in the following paragraphs, and the results should be recorded on an Annual Technical Performance Record form or on a Comprehensive Facility Performance and Adjustment Data form identified as being used for annual revalidation and retained on file at the facility.
04/28/11 AC 150/5220-16D
20
(1) Verify that the maintenance program is being followed and properly documented.
(2) Witness the owner’s maintenance technician performance of a comprehensive check and calibration to verify that system performance is within the limits specified by the manufacturer's documentation and to ensure that every component of the system is operating properly.
(3) Verify that the AWOS configuration is the same as approved at the time of commissioning or as formally modified in accordance with approved configuration control procedures. Additionally, it should be determined that all mandatory configuration changes approved by the FAA have been accomplished and documented.
(4) Verify that a summary of all maintenance, hardware and software, performed since the last report is on file at the facility.
b. FAA Site Visits. FAA inspectors will periodically visit certified non-Federal AWOS facilities. During the visit, the FAA inspector will verify, with the assistance of the owner’s maintenance technician, that the system operates within tolerance, that all maintenance tasks have been properly performed and documented, and that the FAA has approved the AWOS configuration. The inspector may review the facility’s FAA Form 6030-1 log and other documentation to verify that scheduled and unscheduled maintenance has been accomplished and documented in accordance with this AC, the approved FAA/Sponsor MOA/OMM, the approved manufacturer's Maintenance Manual, and the approved annual system revalidation plan. The owner’s maintenance technician holding FAA verification authority should provide access to the site and accomplish any tests on the facility requested by the FAA representative during the visit. The FAA will provide the sponsor a written inspection report following completion of the inspection. The FAA representative may visit the site with a sponsor’s representative without the non-Federal technician’s presence provided no tests or adjustments are planned or accomplished on the AWOS equipment.
c. Mandatory Configuration Changes. If the FAA determines that an AWOS system, or any element of the system, is providing data that could be in error, the FAA may direct the system manufacturer to issue a mandatory configuration change order to the owners of similar systems. The system owner should disable the appropriate part of the system and should request that the FAA issue a NOTAM describing the missing parameter and give an estimate of the time for which it will be disabled.
d. Unacceptable Failure Rate. Equipment that proves unreliable is to be removed from the type certification approval listing. The determination of unreliability should be based on judgment and experience with similar equipment. Where equipment is determined to have an unsatisfactory failure rate or is deficient in workmanship or materials, the manufacturer is to be notified in writing as to the basis for this determination. The manufacturer should then notify the FAA in writing as to
04/28/11 AC 150/5220-16D
21
its plan of action for resolving the issue. If the manufacturer does not resolve the problem within a reasonable time, the equipment would be removed from the type certification approval listing. The timeframe would, of necessity, be based on safety considerations and the nature of the problem. The FAA reserves the right to require the equipment to undergo any or all qualification and calibration tests when the equipment has been determined unreliable or deficient in design, materials, or workmanship. Owners of similar AWOS installations should be notified of any problems uncovered during this retesting through the configuration control procedure discussed in paragraph 2.10.c, and paragraph 2.5, Configuration Control Plan.
e. Note. Failure to meet the criteria of this AC may result in decommissioning the AWOS facility, i.e., withdrawal of the FCC license, and withdrawal of type certification approval.
04/28/11 AC 150/5220-16D
22
[This page intentionally left blank.]
04/28/11 AC 150/5220-16D
23
Chapter 3. PERFORMANCE AND TESTING SPECIFICATIONS FOR AWOS
3.1. GENERAL. This chapter contains the performance standards and testing specifications for components of the AWOS. Equipment should comply with these standards to establish partial compliance with the Code of Federal Regulations (CFR). However, some of the following tests are intended to be performed in a laboratory environment and may not be able to be duplicated in the field. Current standards and tolerances are those which were approved during type certification acceptance. These are intended only as guidelines based on standards approved at type acceptance. If a manufacturer has specified additional checks to be performed, requested and received approval for different checks to be performed, or specified that tighter tolerances be required, then these will be detailed by the manufacturer in the FAA-approved Maintenance Manual for that specific typecertified AWOS.
3.2. DEFINITIONS.
a. Root Mean Square Error (RMSE). RMSE is determined by comparing the output value with the true value of a parameter according to the following equation:
N
M T RMSE
N
N
2
1
Where:
N = Number of independent comparisons M = Measured value T = True value
(RMSE is in the same units as the measured and true values)
b. Time Constant. After a step change in the value of a parameter measured by a sensor, the time constant is the length of time it takes the sensor to register a given percentage (63 percent unless otherwise specified) of the change.
c. Resolution. The resolution of a sensor is the value of the least significant digit that is given as sensor output.
04/28/11 AC 150/5220-16D
24
d. Variance. For the purposes of this AC, variance is defined as the difference between the value of the reference sensor and the sensor under test.
e. Thunderstorm. For purposes of this AC, a thunderstorm occurs when a single cumulonimbus cloud (cell) generates one or more flashes of lightning which can be cloud-to-ground, in-cloud, or cloud-to-cloud. At any one time, a period of storm activity may consist of a number of thunderstorms or cells within the area surrounding the reference point.
3.3. GENERAL PERFORMANCE STANDARDS. This paragraph addresses aspects of performance that are applicable to the AWOS as a whole. The electromagnetic interference, transient, and lightning protection standards are also applicable to the entire system and are addressed in paragraphs 3.22 and 3.23.
a. Input Power. AWOS equipment should operate from a 120/240 V (±10 percent), 60 Hz ac (±5 Hz), 3-wire single-phase service.
b. Loss of Power. The AWOS system should return to normal operation without human intervention after a power outage. When power is restored, the system should not output erroneous data.
c. Wind Sensor Tower. If a separate tower is used for the wind sensor, daytime marking and nighttime lighting should be provided in accordance with the guidelines set forth in the latest edition of AC 70/7460-1, Specification for Obstruction Marking and Lighting.
(1) It should be lighted with a dual obstruction light L-810 fixture placed within five feet of the top of the tower. The two lamps on the L-810 should be wired in parallel. The standards for the L-810 fixtures may be found in latest edition of AC 150/5345-43, Specification for Obstruction Lighting Equipment. Use of a single light emitting diode (LED) obstruction light fixture is encouraged for efficiency and endurance.
(2) Since the nominal height for this tower is 30 to 33 feet and since most towers are manufactured in 10 foot sections, a waiver to AC 70/7460-1 has been granted to permit a six-band marking, with the bands alternating between aviation orange (the top band) and aviation white. This pattern will permit dip painting the tower at the factory without sacrificing the level of safety provided by the standard tower.
d. VHF Transmitter. It is the FAA policy that the output of the AWOS be transmitted on an existing NAVAID voice outlet whenever practical. When the AWOS is broadcast over a NAVAID, that NAVAID will be given a flight check during the initial commissioning procedure and will be given an annual flight check in conjunction with the annual AWOS verification. If there is no
04/28/11 AC 150/5220-16D
25
NAVAID available, then the output will be broadcast via a separate VHF transmitter that will be licensed by the FCC. The transmitter operates in the 118-137 MHz band on a frequency assigned by the FCC. The transmitter will have a FCC type-acceptance with the following operational parameters:
(1) Channel Spacing: 25 kHz
(2) Normal radio frequency (RF) Power Output: Nominal 2.5 watts (± 0.25 watts), at the transmitter output.
Note: Other transmitter powers between 1 and 10 watts may be authorized by the FCC based on unusual circumstances. However, the FCC license always lists the maximum effective radiated power authorized for any AWOS.
e. Coaxial Cable. The manufacturer should use coaxial cable with less than 3 dB line loss per 100 feet for cable runs exceeding 30-feet. The manufacturer may use coax with up to 10 dB loss per 100 feet for lines less than 30-feet long. All critical VHF radio parameters should be measured, using properly calibrated collocated test equipment, and recorded during initial and annual reverification checks. These measurements apply to both discrete frequencies as well as shared frequencies. Table 1, VHF Radio Specifications, provides the critical radio parameters.
Table 1. VHF Radio Specifications
Parameter Specifications
Frequency stability ±0.001 percent (-30o to +60o C)
Percentage of modulation of generated tone
65 percent to 95 percent
Voltage standing wave ratio (VSWR) at transmitter
3.0 to 1
VSWR at antenna for cable runs exceeding 50 feet
3.0 to 1
Line Loss for cable runs exceeding 50 feet < 3 dB of line loss per 100 feet
04/28/11 AC 150/5220-16D
26
Table 1. VHF Radio Specifications (Continued)
Parameter Specifications
Spurious and harmonic emission for cable runs exceeding 50 feet
80 dB down from the carrier minimum up to 90 percent modulation
Emission type 6A3E
Antenna Omnidirectional Occupied Bandwidth No less than 99 percent of the emitted signal energy should be contained within a 25 kHz bandwidth
f. Generation of the NAVAID Identifier by the AWOS. When the AWOS message is broadcast over a NAVAID, the AWOS should be designed to provide both the NAVAID tone identifier and the AWOS weather data over the NAVAID frequency. The tone should be generated between every AWOS voiced weather message and should only be generated between messages. This design should eliminate the interference between the AWOS voice and the NAVAID generated tone identifier and provides for better identification of the NAVAID in marginal conditions. If this design is adopted, it is imperative that the NAVAID automatically return to using its internal tone generator to provide the identifier if the AWOS capability to provide the NAVAID identifier has been lost.
g. UHF Data Link Radio Transmitter. When a UHF radio is used to transfer data between components of the system, the transmitter will have FCC type-acceptance, and the power output should be limited to the minimum necessary to accomplish the job and should not exceed 1 watt. The FCC issues the license for the use of the facility and assigns the frequency. Frequency stability, deviation/percent modulation, VSWR, and initial/operating power output should be in accordance with FCC regulations and should be clearly defined in the manufacturer's Maintenance Manual. AM and FM data link radio transmitter specifications are contained in the latest edition of FAA Order 6560.13.
h. Data Link Radios. No data link radios authorized under Part 15 of the FCC rules identified in Title 47 of the Code of Federal Regulations (47 CFR, Part 15) or other unlicensed transmitters may be used in any part of a non-Federal AWOS system.
i. Code Requirements. The AWOS should be designed in accordance with applicable paragraphs of the latest edition of the National Electrical Code (NEC) and should be installed in accordance with local code requirements.
04/28/11 AC 150/5220-16D
27
3.4. OPERATING ENVIRONMENT. All AWOS equipment and sensors should demonstrate that they meet all operating tolerances under the operational environmental conditions described in this AC.
a. Site Elevation. From 100 feet below sea level to 10,000 feet above sea level.
b. Equipment Installed Indoors in a Conditioned Space.
(1) Temperature. From +40o to +105o F (+5o to +40o C).
(2) Relative Humidity. 5 percent to 90 percent (non-condensing).
c. Equipment Installed Outdoors.
(1) Temperature. Two operational environmental temperature ranges are defined for the outdoor equipment. Class 1 is the minimum environment all outdoor equipment must operate in. Class 2 is the harsh environment the outdoor equipment must operate in when installed in locations known to exceed the Class 1 criteria.
Class 1: -30o to +130o F (-35o to +55o C) Class 2: -65o to +130o F (-55o to +55o C)
(2) Relative Humidity. 5 percent to 100 percent over the entire temperature range in increments of 10o C.
(3) Wind. Up to 85 knots.
(4) Hail. Up to 1/2 inch in diameter.
(5) Ice Buildup. Freezing rain rate equivalent to a buildup of 1/2 inch per hour, lasting for a period of 1 hour with up to 40 knot winds.
(6) Rain. Up to 3-inches per hour, with up to 40 knot winds.
3.5. MECHANICAL WINDSPEED AND DIRECTION SENSOR.
a. Performance Standard.
(1) Windspeed Sensor.
04/28/11 AC 150/5220-16D
28
(a) Range. The sensor should respond to a threshold of 2 knots and a maximum of at least 85 knots.
(b) Accuracy. The windspeed sensor should provide an accuracy of ± 2 knots up to 40 knots. Above 40 knots, RMSE should be within ± 5 percent.
(c) Resolution. The resolution should be 1 knot.
(i) Distance Constant. The distance constant should be less than 10 meters. The method for calculation is given in paragraph 3.5.b.(1)(b).
(ii) Threshold. 2 knots.
(2) Wind Direction Sensor. This sensor should be aligned to true north.
(a) Range. 1to 360in azimuth.
(b) Threshold. 2 knots.
(c) Accuracy. Within 5(RMSE)
(d) Resolution. To nearest 1o; dead band not to exceed 7o wide.
(e) Time constant. Less than 2 seconds.
b. Performance Testing. Testing should be conducted in a calibrated wind tunnel, except for the wind direction accuracy test that is conducted on a bench test fixture. The windspeed sensor should be compared against a calibrated Pitot - static tube or transfer reference standard traceable to the National Institute of Standards and Technology (NIST).
(1) Windspeed.
(a) Accuracy and Resolution. The test is conducted under no rain conditions. Four full-test cycles (2-85 knots) should be conducted in increments of 2 knots between 2 and 10 knots, in increments of 10 knots between 10 and 80 knots, and at 85 knots. During these test runs, data should be gathered to demonstrate compliance with the requirements for accuracy and resolution. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(b) Distance Constant. The distance constant should be computed according to the following formula:
04/28/11 AC 150/5220-16D
29
D = T X W
Where:
D = Distant constant (in meters). T = Time constant. W = Windspeed (meters per second) in the wind tunnel.
The distance constant should be determined from an average of 10 runs, 5 runs each with the tunnel windspeed at 10 knots (5 meter/sec) and at 20 knots (10 meter/sec) with the sensor propeller speed at the zero at time zero. The distance constant should be less than 10 meters for the sensor to pass this test.
(2) Wind Direction.
(a) Accuracy. This test should be conducted on a bench test fixture under no rain conditions. The accuracy of the sensor should be checked at each 10o increment. The accuracy should be checked in 2o increments between 350o and 010o. A dead band of up to 7o wide is permissible. Two complete test cycles should be conducted, and RMSE accuracy should be within specified limits. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(b) Time Constant. The time constant should be determined from an average of 10 runs, 5 runs each with the tunnel speed at 10 knots and at 20 knots. The vane should be displaced 10o from the indicated wind direction and released. The time constant should be less than 2 seconds to reach within 5o of the indicated wind direction.
3.6. ULTRASONIC WIND SENSOR.
a. Performance Standard.
(1) Windspeed.
(a) Range. The sensor should respond to a threshold of 1 knot and a maximum of at least 85 knots.
(b) Accuracy. The windspeed sensor should provide an accuracy of ± 1 knot up to 40 knots. Above 40 knots, RMSE should be within ± 3 percent.
04/28/11 AC 150/5220-16D
30
(c) Resolution. The resolution should be 1 knot.
(d) Distance Constant. The distance constant should be less than 1 meter. The method for calculation is given in paragraph 3.5.b.(1)(b).
(e) Threshold. 1 knot.
(2) Wind Direction Sensor. This sensor should be aligned to true north and withstand a windspeed of 85 knots without damage.
(a) Range. 0to 359in azimuth.
(b) Threshold. 1 knot.
(c) Accuracy. Within 3(RMSE)
(d) Resolution. To nearest 1
b. Performance Testing. Testing should be conducted in a calibrated wind tunnel. The ultrasonic sensor should be compared against a calibrated pitot-static tube or transfer reference standard traceable to the National Institute of Standards and Technology. Ultrasonic anemometers should be tested in a wind tunnel for directions using a rotating base. The mounting base should be able to be rotated as the test progresses. The following test procedures should be used.
(1) Windspeed Accuracy and Resolution. The test is conducted under no rain conditions. Four full-test cycles (2-85 knots) should be conducted in increments of 2 knots between 2 and 10 knots, in increments of 10 knots between 10 and 80 knots, and at 85 knots. During these test runs, data should be gathered to demonstrate compliance with the requirements for accuracy and resolution. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(2) Wind Direction Accuracy. The accuracy of the sensor should be checked at each 10o
increment. The accuracy should be further checked in 2o increments between any 20span. Two complete test cycles should be conducted, and RMSE accuracy should be within specified limits. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
04/28/11 AC 150/5220-16D
31
3.7. TEMPERATURE SENSOR.
a. Performance Standards. The sensor should be thermally isolated to accurately measure environments below:
(1) Range. From -35to +55C (-30to +130F) for Class 1 systems. From -55to +55C (-65to +130F) for Class 2 systems.
(2) Accuracy. 1F RMSE for the entire range of the sensor, with a maximum error of 2F.
(3) Resolution. Not greater than 1F.
(4) Time Constant. Not greater than 2 minutes.
b. Performance Testing.
(1) Accuracy. Temperature accuracy should be verified using a calibrated reference instrument traceable to the National Institute of Standards and Technology (NIST). The temperature sensor should be exercised through the full range of the device in 10F increments. This 10change in chamber temperature should be accomplished within 5 minutes of the test, and the sensor reading should be taken 5 minutes after the chamber temperature is stable. This test cycle should be performed a total of eight times or four times with two sensors in the chamber. These cycles should include two increasing and two decreasing temperature cycles without radiation heating and two increasing and two decreasing temperature cycles with radiation heating on the aspirated enclosure of 1.6 gram-calories per square centimeter per minute (1120 W/m²). The accuracy of the sensor should be within 1F (RMSE) for each test cycle, a total of 9 data points for each Class 1 system cycle; 11 data points for each Class 2 system cycle. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(2) Time Constant. The sensor should be placed in a chamber and stabilized at 85F. The temperature should be rapidly raised (within 1 minute) 5F (to 90F); the time constant should be 2 minutes or less. The same test should be repeated with a 5F decrease in temperature within 1 minute. The time constant should be 2 minutes or less.
3.8. HUMIDITY SENSOR. A single thermal shield and aspirator unit may include both the humidity and temperature sensors.
a. Performance Standards.
(1) Operating Range. From -50to +130F
04/28/11 AC 150/5220-16D
32
(2) Sensor Protection. The humidity sensor should not be damaged if the sensor becomes excessively wet, e.g., from precipitation or from absorption of moisture after a loss of power. The humidity sensor probe should return to normal operation, without damage and without human intervention, within 30 minutes after the abnormal, excessively wet condition is alleviated, i.e., after precipitation ends, or after restoration of power.
(3) Resolution. Not greater than 1%.
(4) Time constant. Less than 2 minutes.
(5) Accuracy. The accuracy should be less than or equal to 5% of the measured value.
b. Performance Testing.
(1) Accuracy. All tests should be performed with the sensor in the aspirated enclosure supplied with the sensor. Temperature and relative humidity accuracy should be verified using calibrated reference instruments traceable to the National Institute of Standards and Technology. The data points given in paragraphs 3.9.b.(1) should be taken during four test runs, two with increasing humidity and two with decreasing humidity. This may be reduced to two test runs if two sensors are placed in the chamber. During the test run, the change in temperature/relative humidity should be accomplished within 5 minutes, and the sensor reading should be taken 5 minutes after the temperature and humidity have stabilized. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(2) Time Constant. At ambient temperature and 50 percent relative humidity, change the humidity equal to a dew point increase of 5F within 1 minute, and then decrease the humidity equal to a dew point decrease of 5F within 1 minute. In each case, the time constant should be less than 2 minutes.
(3) Power Interruption. At ambient temperature and 90 percent relative humidity, with the sensor operating normally, disconnect the power from the sensor for a period of 1 hour. Power should then be reapplied and the sensor should return to normal operation and accuracy within 30 minutes.
3.9. DEW POINT SENSOR. A single thermal shield and aspirator unit may include both the dew point and temperature sensors.
a. Performance Standards.
04/28/11 AC 150/5220-16D
33
(1) Operating Range. From -35to +55C (-30to +130F) for Class 1 systems.
From -55to +55C (-65to +130F) for Class 2 systems
(2) Dewcell Protection. If the dew point sensor is a dewcell, it should not be damaged if the sensor becomes excessively wet, e.g., from precipitation or from absorption of moisture after a loss of power. The dewcell probe should return to normal operation, without damage and without human intervention, within 30 minutes after the abnormal, excessively wet condition is alleviated i.e., after precipitation ends or after restoration of power.
(3) Resolution. Not greater than 1F.
(4) Time constant. Less than 2 minutes.
(5) Accuracy. The accuracy should be as follows. All errors are RMSE.
(a) 2F dew point for dry bulb temperatures of +30to +90F, 80 to 100 percent relative humidity, with a maximum error of 3F at any dry bulb temperature.
(b) 3F dew point for dry bulb temperature of +30to +120F, 15 to 75 percent relative humidity, with a maximum error of 4F at any dry bulb temperature.
(c) 4F dew point for dry bulb temperatures of -20to +20F, 25 to 95 percent relative humidity with a maximum error of 5at any dry bulb temperature. The minimum dew point required is -30F.
b. Performance Testing.
(1) Accuracy. All tests should be performed with the sensor in the aspirated enclosure supplied with the sensor. Temperature and dew point accuracy should be verified using calibrated reference instruments traceable to the National Institute of Standards and Technology. The data points given in paragraph 3.9.b.(1)(a) through 3.9.b.(1)(c) should be taken during four test runs, two with increasing humidity and two with decreasing humidity. This may be reduced to two test runs if two sensors are placed in the chamber. During the test run, the change in temperature/relative humidity should be accomplished within 5 minutes, and the sensor reading should be taken 5 minutes after the temperature and humidity have stabilized. The following data points should be demonstrated and the RMSE calculated to demonstrate the error in each category. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(a) With an error not to exceed 2F (RMSE) dew point
04/28/11 AC 150/5220-16D
34
30F temperature; 80, 90, 100 percent relative humidity 60F temperature; 80, 90, 100 percent relative humidity 90F temperature; 80, 90, 100 percent relative humidity
(b) With an error not to exceed 3F (RMSE) dew point
30F temperature; 15, 45, 75 percent relative humidity 60F temperature; 15, 45, 75 percent relative humidity 90F temperature; 15, 45, 75 percent relative humidity 120F temperature; 15, 40 percent relative humidity
(c) With an error not to exceed 4F (RMSE) dew point
-30F temperature; between 65 and 95 percent relative humidity 0F temperature; 25, 60, 95 percent relative humidity +20F temperature; 25, 60, 95 percent relative humidity
(2) Time Constant. At ambient temperature and 50 percent relative humidity, change the dew point +5F (within 1 minute), and then -5F (within 1 minute). In each case, the time constant should be less than 2 minutes.
(3) Power Interruption. At ambient temperature and 90 percent relative humidity, with the sensor operating normally, disconnect the power from the sensor for a period of 1 hour. Power should then be reapplied and the sensor should return to normal operation and accuracy within 30 minutes.
3.10. PRESSURE SENSOR. Two or three pressure sensors should be provided for each AWOS system. All pressure sensors should have provisions for venting to the outside through a pressure port. Pressure variations due to airflow over the pressure port should be avoided. Sensor venting should be designed to avoid any damp pressure variation and oscillation due to pumping or breathing of the pressure sensor, venting, and porting equipment. Means should be provided to avoid insect nesting and moisture entrapment in the venting.
a. Performance Standards.
(1) Altitude Ranges. High pressure should be standard atmospheric pressure at -100 feet plus 1.5 inches of mercury (inHg) (30.03 + 1.5 = 31.53 inHg). Low pressure should be standard atmospheric pressure at +10,000 feet minus 3.0 inHg (20.58 - 3.00 = 17.58 inHg).
04/28/11 AC 150/5220-16D
35
(2) Pressure Range. Each sensor should be capable of measuring a pressure range at any fixed location (station) of +1.5 to -3.0 inHg from the standard atmospheric pressure at that location.
(3) Accuracy. The accuracy should be 0.02 inHg RMSE at all altitudes from -100 to +10,000 feet mean sea level (MSL), maximum error 0.02 inHg at any one pressure.
(4) Resolution. The resolution of the barometer should be displayed in 0.001 inHg increments or better.
(5) Differential Accuracy. Each sensor should exhibit an average differential accuracy of 0.02 inHg or less between a series of two pressure measurements taken from the same sensor 3 hours apart. Ambient temperature over this 3-hour period should not change more than 5F. Ambient pressure should not vary more than 0.04 inHg (RMSE) over the 3-hour period.
(6) Maximum Drift With Time. Each sensor should be stable and continuously accurate within 0.02 inHg RMSE for a period of not less than 6 months. The maximum error should be 0.02 inHg.
b. Performance Tests.
(1) Accuracy. Each pressure sensor should successfully complete the following accuracy test. A calibrated barometer or transfer standard with an accuracy of at least 0.004 inHg, that is traceable to the National Institute of Standards and Technology (NIST), should be used as a standard during testing. Two test cycles should be performed on each pressure sensor. One test cycle is defined as running the sensor through the full pressure range at each of three ambient temperatures. Before taking measurements, allow sufficient time for the sensor to achieve steady state at each data point not to exceed 5 minutes. The RMSE should be within the specified limits. Tests demonstrating acceptable accuracy during environmental extremes as listed in paragraph 3.4 should be conducted.
(a) Pressure Range. The pressure sensors should be tested through the full range of performance, normally 17.5 to 32.0 inHg, in 1-inHg increments of both increasing and decreasing pressure.
(b) Temperature Range. The sensor should be tested at ambient (approximately +85) and at the hot and cold extremes called for in the environmental requirements.
(2) Differential Accuracy. Differential accuracy, i.e., change in accuracy, of the pressure sensor should be tested at ambient temperature (approximately 85F) and ambient barometric pressure.
(a) Take 14 measurements of pressure on the pressure sensor under test and 14 measurements of pressure on the reference barometer. These measurements should be taken about
04/28/11 AC 150/5220-16D
36
5 seconds apart and all 14 measurements should be completed within 90 seconds. This time should be called t=0.
(b) Repeat the 14 measurements on the pressure sensor under test and 14 measurements of pressure on the reference barometer after an elapsed time of 3 hours. The ambient temperature should have changed less than 5F, and the ambient pressure should have changed not more than 0.1 inHg. This time should be called t=3.
(c) Compute the average reading of the reference barometer at t=0. Compute the average reading of the reference barometer at t=3. Determine the difference in the two averages. If the difference is greater than 0.1 inHg, or if the average difference between the reference and the test barometer at either t=0 or t=3 is greater than 0.02 inHg, repeat steps (a) and (b).
(d) Compute the 14 errors in reading between the sensor and reference barometer at t=0.
(e) Compute the 14 errors in reading between the sensor and reference barometer at t=3.
(f) Subtract the 14 t=0 errors from the 14 t=3 errors determined in steps (d) and (e). Preserve the order of subtraction such that the first t=0 error is subtracted from the first t=3 error. These differences are the changes in accuracy, i.e., the differential accuracy.
(g) Compute the average and standard deviation of the 14 changes in accuracy determined in step (f). The average differential accuracy should be no greater than 0.02 inHg. The standard deviation should be less than 0.004 inHg.
(3) Resolution. The manufacturer should demonstrate that the barometer resolution is displayed in 0.001 inHg increments or greater.
(4) Drift Over Time. Testing should be accomplished to determine maximum drift, paragraph 3.10.a.(6), over a 6-month period and should not exceed 0.02 inHg.
3.11. CLOUD HEIGHT SENSOR. The cloud height sensor should have a design range of at least 12,500 feet. The sensor should provide an output of at least three cloud layers representative of the sky conditions when surface visibilities are equal to or greater than 1/4 mile. The sensor should comply with the performance standards throughout its design range.
a. Performance Standards. The sensor should detect the height of atmospheric phenomena, i.e., clouds and obscuring phenomena aloft, or in the event the phenomena are surface based, e.g.,
04/28/11 AC 150/5220-16D
37
fog, provide an estimate of the contact height (CH) or vertical visibility (VV). CH is defined as the vertical height above ground at which visual reference to recognized lights or objects on the surface can be established sufficiently to permit visual determination of the ground plane and position. VV is defined as the vertical distance that an observer can see vertically into surface-based obscuring phenomena, e.g., dust, fog, sand, etc., or the height corresponding to the upper limit of the return of the ceilometer signal, or the height corresponding to the height at which a balloon would completely disappear during the presence of surface-based phenomena, i.e., an obscured sky. The sensor should have the capability of discriminating between a negative response, i.e., no hit, resulting from no phenomena within the sensor's design range, and a sensor error/fault. The sensor should not indicate a response, i.e., hit, that is not the result of the detection of atmospheric phenomena.
(1) Range. The sensor should measure cloud heights and the heights of obscuring phenomena aloft to a minimum of 12,500 feet.
(2) Accuracy. Under laboratory conditions, the sensor should provide an accuracy of 100 feet or 5 percent, whichever is greater.
(3) Resolution. Not greater than: 50-feet surface to 5,500 feet; 250 feet from 5,501 to 10,000 feet; 500 feet above 10,000 feet.
(4) Detection Performance. The sensor should perform within the limits specified in paragraphs 3.11.b.(2) and 3.11.b.(3).
(5) Sampling. The sensor should provide an output at least once every 30 seconds. However, to extend sensor life, this sampling rate may be reduced to provide at least one sample every 3 minutes when no cloud, obscuring phenomena aloft, or CH/VV values, i.e., hits, are detected for the preceding 15 minutes.
(6) Eye Safety. The cloud height sensor should be designed to conform to laser radiation Class IIIb as defined in ANSI-Z 136.1, Accessible Emission Limits for Laser Radiation, with the maximum accessible emission level applied to direct viewing without optical instruments excluding ordinary eye glasses. This document may be obtained from the American National Standards Institute, 1430 Broadway, New York, New York, 10018. Interlock device(s) in the laser power circuit should be provided to disable the laser when any doors are open or the cover is removed to prevent inadvertent exposure of the laser emission to the eyes of the technician or others. The interlock(s) may have a manual override in order that power can be purposely restored during maintenance.
(7) Laser Power Stability. The sensor should contain a self-check, self-adjusting feature that should maintain laser output power at the level necessary to sustain sensor detection and accuracy. When this adjustment can no longer provide the compensation necessary to maintain the sensor within specified operational limits, sensor operation should be terminated.
04/28/11 AC 150/5220-16D
38
(8) Optics Contamination. An air blower or other device should be used to reduce the contamination of the sensor optics. A signal should be generated to indicate the amount of optics contamination, thereby indicating the need for optics cleaning.
(a) Snow. The ceilometer window should demonstrate an ability to remain clear of snow under the condition of snow accumulating at a rate of 2 inches per hour for 1 hour at a temperature of 20F.
(b) Ice. The ceilometer window should remain clear of ice for 60 minutes under conditions of freezing rain with a maximum accretion rate of ½-inch per hour radial thickness of clear ice.
b. Performance Testing.
(1) Accuracy Test. The signal should be projected horizontally to a target at known distances, two distances, separated by at least 1,000 feet, from 100 to 5,500 feet; two distances, separated by at least 1,000 feet, from 5,600 to 10,000 feet; and one distance beyond 10,000 feet. All range points should be within the accuracies specified in paragraph 3.11.a.(2). This test is a laboratory test conducted at full rated power output. It is not intended to be duplicated when the AWOS is installed in the field.
(2) Detection Tests Under Uniform Sky Conditions.
(a) Test Conditions. The sensor should be tested under the following conditions.
(i) Group A. Visibility greater than 3 miles, with a minimum of 10 percent of the data sets in each subgroup as shown in Table 2, collected with light precipitation, i.e., rain and snow, occurring, and a minimum of 10 percent with moderate precipitation, i.e., rain and snow, occurring.
Table 2. Group A Test Conditions
Subgroup Cloud Height (feet)
1 100-700
2 800-1500
3 1600-3000
4 3100-5500
04/28/11 AC 150/5220-16D
39
5 5600-12500
(ii) Group B. Visibility equal to or less than 3 miles, but equal to or greater than 1 mile, with a minimum of 10 percent of the data sets in each subgroup as shown in Table 3, with light precipitation, i.e., rain and snow, occurring, and a minimum of 10 percent with moderate precipitation, i.e., rain and snow, occurring.
Table 3. Group B Test Conditions
Subgroup Cloud Height (feet)
1 100-700
2 800-1500
3 1600-3000
4 3100-5500
5 5600-12500
(iii) Group C. Visibility equal to or greater than 1/4, but less than 1 mile, with a minimum of 10 percent of the data sets in each subgroup as shown in Table 4, collected with light precipitation, i.e., rain and snow, occurring, and a minimum of 10 percent with moderate precipitation, i.e., rain and snow, occurring.
Table 4. Group C Test Conditions
Subgroup Cloud Height (feet)
1 100-700
2 800-1500
3 1600-3000
4 3100-5500
5 5600-12500
04/28/11 AC 150/5220-16D
40
(iv) Group D. Not more than 3/10 total sky coverage with the lowest cloud layer at 2,000 feet or higher under the visibility conditions shown in Table 5, with a maximum of 80 percent of the data in each subgroup collected under daytime conditions.
Table 5. Group D Test Conditions
Subgroup Visibility (miles)
1 Equal to or greater than 1, but less than 3
2 Equal to or greater than 3, but less than 7
3 Equal to or greater than 7
(b) Collection of Test Data.
(i) A minimum of 25 data sets should be collected for each subgroup in Groups A through C, i.e., a minimum of 125 data sets should be collected under each group. However, if weather conditions at the test site over a period of 1 year make collection of at least 25 data sets in every subgroup impossible, the FAA should consider approval of a lesser number of data sets in the affected subgroups after analysis of available data. Further, for test data to be acceptable, a continuous test period should be selected to allow for collection of representative data.
(ii) Also, it should be clear that all data collected during the test period were considered. Any data not used should be explained. For example, if data analysis in a subgroup is truncated after 25 data sets are analyzed, this fact should be documented and explained.
(iii) One data set is defined as the second 10-minute period during which a uniform cloud or obscuration is detected by a rotating beam ceilometer (RBC) or is determined by a qualified weather observer. In order to be classified as a uniform cloud or obscuration, the RBC should continuously measure or a qualified weather observer should determine a cloud, obscuration aloft, or vertical visibility height for a 30-minute period that does not vary from its mean height by more than the variance shown in Table 6 more than 5 percent of the time.
(iv) A minimum of 25 data sets should be collected for each subgroup under Group D. One data set is defined as the second 10-minute period of any consecutive 30-minute period during which the cloud/sky coverage/visibility conditions specified for group D are met.
04/28/11 AC 150/5220-16D
41
Table 6. Criteria for Determining Uniform Cloud Layers
Mean Height (as determined by observer or as measured
by RBC)
Variance
(feet)
Equal to or less than 1,000 ft. 200
Greater than 1,000 ft., but equal to or less than 2,000 ft. 300
Greater than 2,000 ft., but equal to or less than 3,000 ft. 400
Greater than 3,000 ft., but equal to or less than 5,000 ft. 500
Greater than 5,000 ft., but equal to or less than 7,000 ft. 600
Greater than 7,000 ft., but equal to or less than 9,000 ft. 700
Greater than 9,000 ft., but equal to or less than 12,500 ft. 800
(c) Test Standards
(i) An FAA-approved cloud height indicator whose accuracy is traceable to an FAA or NWS approved and calibrated ceilometer standard, or observations taken by a qualified weather observer, should be the standard for determining heights and sky conditions.
(ii) An FAA-approved visibility sensor whose accuracy is traceable to an FAA standard should be the standard for determining visibilities.
(iii) Liquid precipitation measurements should be made using an FAA-approved 0.01 inch per tip tipping bucket precipitation gauge. Light precipitation is defined as one, but not more than two buckets tips in a 10-minute period. Moderate precipitation is defined as more than two, but not more than five tips in a 10-minute period. Heavy precipitation is defined as more than five tips in a 10-minute period. A qualified weather observer should determine the intensity of frozen precipitation.
(d) Criteria for Acceptance Under Uniform Sky Conditions.
(i) Groups A, B, and C Conditions. The mean height of the cloud, obscuration aloft, or vertical visibility measured by the RBC or determined by a qualified weather observer should be determined for each data set. The variance for each cloud, obscuration aloft, and CH/VV height, i.e., hit, detected by the candidate sensor in each data set should be computed. Eighty-eight percent of the data sets within a subgroup, e.g., 22 out of 25 minimum, should satisfy the following condition: 90 percent of the heights determined by the candidate sensor in each data set should agree with the mean height measured by the RBC or determined by a qualified weather observer within the
04/28/11 AC 150/5220-16D
42
variance limits as shown in Table 7, Criteria to Satisfy Groups A, B, and C Conditions. Negative responses, i.e., no hits by the candidate sensor, should be included as data points and considered to be outside the variance limits. Also, the no-hit percentage in each subgroup should not exceed 5 percent. The candidate sensor should successfully demonstrate the conditions in Table 7, Criteria to Satisfy Groups A, B, and C Condition, for each subgroup to pass this test. Failure of any subgroup constitutes failure of the test.
Table 7. Criteria to Satisfy Groups A, B, and C Conditions
Mean Height (as determined by observer or as
measured by RBC)
Variance (feet) for
Cloud and Obscuration Aloft
Heights (feet)
Variance for CH/VV Values (feet)
Equal to or less than 1,000 ft. 200 400
Greater than 1,000 ft., but equal to or less than 2,000 ft. 300 600
Greater than 2,000 ft., but equal to or less than 3,000 ft. 400 800
Greater than 3,000 ft., but equal to or less than 5,000 ft. 500 1,000
Greater than 5,000 ft., but equal to or less than 7,000 ft. 600 1,200
Greater than 7,000 ft., but equal to or less than 9,000 ft. 700 1,400
Greater than 9,000 ft., but equal to or less than 12,500 ft. 800 1,600
(ii) Group D conditions. Not more than one false hit per data set in each subgroup. More than one false hit per data set should constitute failure of the test.
(3) Detection Tests Under Ragged Overcast or Obscured Sky Conditions.
(a) Heights, cloud/obscuration aloft or CH/VV, measured by the candidate sensor should be compared with heights measured by the RBC or determined by a qualified weather observer during ragged overcast or obscured sky conditions. Valid data should be that collected during overcast or obscured sky conditions below 12,500 feet as verified by an RBC hit percentage of 95 percent or more, or as determined by a qualified weather observer, during a 20-minute period. Negative responses, i.e., no hits, should be included as data points and considered to be outside the variance limits. Calculate the percent of heights, i.e., hits, by the candidate sensor falling within the ranges identified in paragraph 3.11.b.(3)(b) under each of the conditions specified in paragraph 3.11.b(3)(c) with allowable height variances as specified as in Table 7. Data should be collected under as many of the conditions as possible; however, the FAA may accept less than the specified
04/28/11 AC 150/5220-16D
43
requirement after evaluation of the available data. For test data to be accepted, a continuous test period should be selected to allow for representative data collection. It should also be clear that all data collected during the test period were considered. Any data not used should be explained.
(b) Height ranges (as determined by RBC or qualified observer)
(i) 100 - 700 feet (ii) 800 - 1,500 feet (iii) 1,600 - 3,000 feet (iv) 3,100 - 5,500 feet (v) 5,600 - 12,500 feet
(c) Conditions:
(i) No precipitation. Visibilities 1/4 to 1 mile, 1 to 3 miles, and greater than 3 miles.
(ii) Light or moderate precipitation (rain and snow). Visibilities 1/4 to 1 mile, 1 to 3 miles, and greater than 3 miles.
(iii) Heavy precipitation (rain and snow). Visibilities 1/4 to 1 mile, 1 to 3 miles, and greater than 3 miles.
(d) A minimum of 90 percent weighted average of the hits by the candidate sensor should fall within the range of the RBC or within the height range determined by a qualified weather observer. Also, the weighted negative response, i.e., no hit, percentage should not exceed 5 percent.
3.12. VISIBILITY SENSOR.
a. Performance Standards.
(1) Range. The visibility sensor should be capable of determining visibilities from less than 1/4 mile to 10 miles. A method of calibration traceable to the FAA-approved standards in paragraph 3.12.b should be provided.
(2) Resolution. In terms of equivalent visibility, the sensor should provide data to report visibility values as follows in statute miles: less than 1/4, 1/4, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 5, 7, 10 and greater than 10 miles. For information, refer to Federal Meteorological Handbook 1 (FMH-1).
04/28/11 AC 150/5220-16D
44
(3) Accuracy. The sensor should agree with the transmissometer standards as shown in Table 8, Visibility Sensor Accuracy Requirement.
Table 8. Visibility Sensor Accuracy Requirement.
Reference Transmissometer Reading Acceptable Sensor Variance
1/4 through 1-1/4 miles ± 1/4 mile
1-1/2 through 1-3/4 miles + 1/4, -1/2 mile
2 through 2-1/2 miles ± 1/2 mile
3 through 3-1/2 miles + 1/2, -1 mile
4, and greater than 4 miles ± 1 mile
(4) Time Constant. The time constant should not exceed 3 minutes.
(5) Ambient Light Sensor. The visibility sensor should contain an ambient light sensor, i.e., a photocell, to measure the ambient luminance within its field of view and generate a signal to the visibility sensor to indicate whether the ambient light level is day or night. It should indicate day for increasing illumination between 0.5 and 3 foot-candles (FC) and night for decreasing illumination between 3 and 0.5 FC. This sensor may be exposed to ambient light levels as high as 50 FC.
b. FAA-Approved Visibility Standards. The high visibility reference standard should be a visible light transmissometer(s) that uses a narrow band of light centered at 0.55 microns, 95 percent of the response within ±0.03 microns of 0.55 microns, for visibility ranges to an extinction coefficient of 3 mile-1. At higher extinction coefficients, an FAA-approved transmissometer(s) that includes some infrared radiation may be substituted as a standard. Comparisons with scatter-type instruments different from those being tested may be used to correct for small drifts in reference standard calibration.
c. Performance Tests. The visibility sensor should be tested using FAA-approved transmissometers as the reference standard.
(1) Accuracy Testing.
(a) At least 2 months of accuracy test data should be accumulated, assuring that a representative number of valid test points are experienced at each of the reporting increments provided in paragraph 3.12.a.(2), and under conditions of both with and without precipitation. All
04/28/11 AC 150/5220-16D
45
data collected during the test should be included in the test report. Any samples not included in determining the candidate sensor's accuracy should be fully explained. For example, data collected under inhomogeneous conditions may be excluded from the accuracy analysis, if so explained. The test data should consist of a number of independent samples of 10 minutes each, with at least 5 minutes between each sample. Samples should consist of visibilities from less than 1/4 mile, to greater than 10 miles, and should be weighted in the following ratio:
(i) 70 percent without precipitation, i.e., with fog, under clear conditions, and with approximately 5 percent of the data points collected under summer haze conditions
(ii) 30 percent with precipitation, e.g., 15 percent with rain, 15 percent with snow
(b) Eighty percent (overall weighted average) of the total of all sensor test data points should agree with the transmissometer standard within the allowed variances from less than 1/4 through 5 miles.
(c) Eighty percent of the sensor test samples that are obtained when the transmissometer reads greater than 5 miles should be 5 miles or greater.
(2) Time Constant Demonstration. Under conditions of 10-mile visibility, a technique should be used to reduce the sensor detector output to 1 mile or less. After the restriction is applied, the time constant should be measured to reflect the reduction of visibility. After a period of 10 minutes, the artificial restriction to visibility should be removed, and the sensor time constant should be measured to reflect the increase in visibility. The time constant should be equal to or less than 3 minutes.
(3) Ambient Light Sensor Testing. The manufacturer should demonstrate that the ambient light sensor complies with paragraph 3.12.a.(5) and the visibility output is updated accordingly when the light sensor changes status from day-to-night or night-to-day.
3.13. PRECIPITATION ACCUMULATION SENSOR. The term precipitation is defined as including all forms, i.e., liquid, freezing, frozen, or combinations thereof. The term precipitation amount is the liquid or liquid equivalent amount. There are generally two types of precipitation accumulation sensors, the tipping bucket rain gauge and the precision scale. The tipping bucket design measures every tip, e.g., 0.01 inches. The precision scale, sometimes referred to as an all weather precipitation accumulation gauge (AWPAG), measures the weight of the precipitation and reports it as inches of rain.
a. Performance Standards. The sensor should be capable of estimating the precipitation amount with a range of 0.01 to 5-inches per hour, with a resolution of 0.01 inches and an accuracy of 0.002 inches per hour (RMSE), or 4 percent of actual, whichever is greater.
04/28/11 AC 150/5220-16D
46
b. Performance Testing. The manufacturer should conduct a test program to demonstrate that the precipitation accumulation sensor(s) meet the performance requirements under the environmental conditions found in paragraph 3.4.
3.14. PRESENT WEATHER DETECTOR/SENSOR. The term precipitation type as used herein includes the following: rain, drizzle and snow. The precipitation type sensor should provide an indication of the type of precipitation occurring, or should output precipitation for any precipitation, e.g., liquid, freezing, frozen, or combinations thereof, when a type cannot be identified. However, recognizing that the sensor technology is not yet available to identify ice pellets and hail, a precipitation type sensor may qualify by identifying only rain, drizzle, and snow while outputting precipitation for those types not identified. The sensor unit may be designed as a separate unit or may be combined with the requirements of other parts of this AC, e.g., paragraph 3.12, Visibility Sensor, so that one unit fulfills the requirements of two or more paragraphs.
a. The sensor should identify the type of precipitation when the rate of precipitation equals or exceeds 0.002 inches per hour, with the goals for accuracy as follows:
(1) Within the temperature range of:
(a) +28F to +38F, identify precipitation type correctly as:
(i) Rain: 90 percent of the cases.
(ii) Drizzle: 80 percent of the cases.
(iii) Snow: 90 percent of the cases.
(b) Less than +28F. Identify precipitation type correctly as snow in 99 percent of the cases.
(c) Greater than +38F, identify precipitation type correctly as:
(i) Rain: 99 percent of the cases.
(ii) Drizzle: 90 percent of the cases.
(2) Priority: Only one precipitation type should be reported, with the reporting priority established in the following order.
04/28/11 AC 150/5220-16D
47
(a) Snow.
(b) Rain.
(c) Drizzle.
(d) Precipitation, unidentified.
b. Performance Tests. The manufacturer should conduct a test program to demonstrate that the sensor satisfies the performance standards under the environmental conditions in paragraph 3.4. As a minimum, the following test conditions should be satisfied.
(1) Prior to testing, the AWOS manufacturer should develop and submit a test plan to the FAA AWOS Non-Federal Engineering Office for approval at the address provided in paragraph 1.3.e.(2) The test plan should clearly outline the tests to be performed, it should define the capabilities of the sensor to be tested, and it should include a detailed description of the test procedures. It should contain a clear statement of pass/fail criteria. The test plan should identify the location(s) and the proposed time planned for the tests. All data collected during the test should be incorporated into the test report. Any data not included in determining the candidate sensor's compliance with the requirements of this circular should be fully explained.
Continue reading ↓ 120 of 188 passages shown