AC 145-9 Guide for Developing and Evaluating Repair Station and Quality Control Manuals
This advisory circular (AC) provides information material for all repair station certificate holders or applicants under Title 14 of the Code of Federal Regulations (14 CFR) part 145 to develop and evaluate a Repair Station Manual (RSM) and Quality Control Manual (QCM). This AC describes an acceptable, but not the only means, to develop a manual and comply with the referenced regulations.
This document is cancelled. It may have been replaced. Check the official source before relying on it.
2. PRINCIPLE CHANGES.
U.S. Department of Transportation Federal Aviation Administration
Advisory Circular
Subject: Guide for Developing and
Evaluating Repair Station and Quality Control Manuals
Date: 3/19/09 Initiated by: AFS-300
AC No: 145-9 Change: 1
1. PURPOSE. This advisory circular (AC) has been revised to update contract maintenance information.
2. PRINCIPLE CHANGES. This change updates information on contract maintenance.
PAGE CONTROL CHART
Remove Pages Dated Insert Pages Dated
i and iii 7/3/03 i and iii 3/19/09
32 through 35 7/3/03 32 through 35 3/19/09
ORIGINAL SIGNED by Chester D. Dalbey for John M. Allen Director, Flight Standards Service
4. DEFINITION OF TERMS. › f. Correction. An action taken to eliminate a detected nonconformity.…
U.S. Department of Transportation Federal Aviation Administration
Advisory Circular
Subject: Guide for Developing and
Evaluating Repair Station and Quality Control Manuals
Date: 3/19/09 Initiated by: AFS-300
AC No: 145-9 Change: 1
1. PURPOSE. This advisory circular (AC) provides information material for all repair station certificate holders or applicants under Title 14 of the Code of Federal Regulations (14 CFR) part 145 to develop and evaluate a Repair Station Manual (RSM) and Quality Control Manual (QCM). This AC describes an acceptable, but not the only means, to develop a manual and comply with the referenced regulations.
2. CANCELLATION. This AC cancels AC 145-3, Guide for Developing and Evaluating Repair Station Inspection Procedures Manuals, dated February 13, 1981.
3. RELATED 14 CFR PARTS. Title 14 CFR parts 1, 21, 43, 65, 91, 121, 125, 129, 135, and 145.
4. DEFINITION OF TERMS.
a. Acceptable. Data that meets the requirements of the applicable regulations.
b. Accountable Manager. The person designated by the certificated repair station to be responsible for and have authority over all repair station operations conducted under part 145. This person’s duties include ensuring that repair station personnel follow regulations, and serving as the primary contact with the Federal Aviation Administration (FAA).
c. Approved. Approved by the Administrator unless used with reference to another person. Approval is granted to a repair station when the information, such as a process specification or rating, is listed on the operations specifications (OpSpecs).
d. Article. An aircraft, airframe, aircraft engine, propeller, appliance, or component part.
e. Contracting. Entering into an agreement between the originating certificated repair station and another person or people to perform maintenance functions on an article. The originating repair station will exercise the privileges of its certificate and assume responsibility for the work performed by the contracted person(s).
f. Correction. An action taken to eliminate a detected nonconformity. For repair stations electing to use an International Organization for Standardization (ISO 9000) quality system, a correction may involve repair or rework and may be made in conjunction with a corrective action.
n. Major Repair. A repair that: › (2) Is not done according to accepted practices or cannot be done by…
g. Corrective Action. An action taken to eliminate the cause of a detected nonconformity or other undesirable condition to prevent its reoccurrence. For repair stations electing to use an ISO 9000 or similar system, the undesirable condition may include potential regulatory violations, which differs from a nonconformity requiring correction.
h. Designated Engineering Representative (DER). A private person designated by the FAA Administrator to act as its representative for examining, inspecting, and testing aircraft and related data. A DER may recommend approval or approve data within the limitations of his or her certificate of authority.
i. Directly in Charge. Responsible for the work of a certificated repair station that performs maintenance, preventive maintenance, alterations, or other functions affecting aircraft airworthiness. A person directly in charge doesn’t need to physically observe and direct each worker constantly, but must be available for consultation on matters requiring instruction or decision from higher authority.
j. Line Maintenance.
(1) Any unscheduled maintenance resulting from unforeseen events; or
(2) Scheduled checks that contain servicing and/or inspections that do not require specialized training, equipment, or facilities.
k. Maintenance. Inspection, overhaul, repair, preservation, and the replacement of parts, excluding preventive maintenance.
l. Maintenance Function. A step or series of steps in the process of performing maintenance, preventative maintenance, or alterations, which may result in approving an article for return to service.
m. Major Alteration. An alteration not listed in the aircraft, aircraft engine, or propeller specifications that:
(1) Might appreciably affect weight, balance, structural strength, performance, power plant operation, flight characteristics, or other qualities affecting airworthiness; or
(2) Is not done according to accepted practices or cannot be done by elementary operations.
n. Major Repair. A repair that:
(1) If improperly done, might appreciably affect weight, balance, structural strength, performance, power plant operation, flight characteristics, or other qualities affecting airworthiness; or
(2) Is not done according to accepted practices or cannot be done by elementary operations.
Page ii
4. DEFINITION OF TERMS. › 5. BACKGROUND.
3/19/09 AC 145-9 CHG 1
o. Operations Specifications (OpSpecs). The official document that describes the authorizations, ratings, and limitations of the repair station.
p. Preventive Action. An action taken to eliminate the cause of a potential nonconformity or other potentially undesirable situation. For repair stations electing to use an ISO 9000 system, preventative action is taken to prevent an occurrence, whereas corrective action is taken to prevent a reoccurrence. For a repair station using an American Society for Quality (ASQ) system, preventative action is taken to remove or improve a process to prevent potential future occurrences of a nonconformance.
q. Preventive Maintenance. Simple or minor preservation operations and the replacement of small standard parts not involving complex assembly operations.
r. Procedure. A specified way to perform an activity or a series of steps, such as a procedure that describes the methods, steps, or means to carry out policy.
s. Quality Control Manual (QCM). A manual that describes the inspection and quality control procedures used by the repair station.
t. Rating. A part of the repair station’s certificate that describes the special conditions, privileges, or limitations issued under part 145, §§ 145.59 and/or 145.61.
u. Repair Station Manual (RSM). A manual that describes the procedures and policies of a repair station’s operations.
v. Required Inspection Item (RII). An item of maintenance that, if not performed properly, or done with improper parts or materials, could result in a failure, malfunction, or defect, endangering the safe operation of the aircraft. An RII must be inspected by a trained, qualified, and authorized inspector. The inspector must be listed on the repair station’s roster but can’t be the same individual who performed the work. See parts 121, 125, and 135, §§ 121.371, 125.251, and 135.429 for details of this requirement.
w. Supervisor. A person who directs the work performed under the repair station’s certificate and OpSpecs and is available in person at the repair station when work is being performed. See part 145, § 145.153 for supervisory personnel requirements.
5. BACKGROUND. The FAA has revised part 145, the regulation for repair stations because many of the former repair station regulations did not reflect advancements in the repair station business, and technologies. Part 145 reorganizes the requirements applicable to repair stations to reduce duplication of regulatory language and eliminate obsolete information. It also clarifies the minimum requirements for an RSM, introduces a QCM, and describes the items that should be included in these manuals.
Page iii
4. DEFINITION OF TERMS. › Chapter 1.
CONTENTS Paragraph … Page
CHAPTER 1. GENERAL INFORMATION … 1
1-1. Purpose … 1 1-2. The Manual(s) … 1 1-3. Combining Portions of the Repair Station Manual with the Quality Control Manual … 3 1-4. Identification and Control of Sections … 4 1-5. Sample Procedure Formats … 5
CHAPTER 2. MANUAL REVISION AND CONTROL … 11
2-1. Procedures for Revision … 11 2-2. Provisions for Control … 12 2-3. Electronic Format … 12
CHAPTER 3. REPAIR STATION ORGANIZATION CHART … 15
3-1. Organization Chart … 15 3-2. Duties and Responsibilities … 16
CHAPTER 4. REPAIR STATION AND QUALITY CONTROL MANUAL ELEMENTS … 19
4-1. Repair Station Personnel Roster … 19 4-2. Operations, Housing, Facilities, Equipment, and Materials … 21 4-3. Capability List … 23 4-4. Training Program Revision … 26 4-5. Work Performed at Another Location … 27 4-6. Maintenance, Preventive Maintenance, and Alterations Performed for Air Carriers Under Parts 121, 125, 129, and 135 … 29 4-7. Contract Maintenance Information … 32 4-8. Proficiency of Inspection Personnel … 37 4-9. Current Technical Data … 39 4-10. Inspection and Quality Control System … 41 4-11. Required Records and Recordkeeping … 50 4-12. Calibration of Measuring and Test Equipment … 53 4-13. Taking Corrective Action on Deficiencies … 56
APPENDIX 1. FORMS (2 pages) … 1 APPENDIX 2. CHECKLIST (12 pages) … 1
Page iv
(1) RSM Elements. › (a) Manual Revision and Notifying the CHDO.
CHAPTER 1. GENERAL INFORMATION
1-1. PURPOSE. This document is a guide for developing and evaluating the RSM and QCM required by part 145,§§ 145.207 through 145.211. This guide does not provide a complete sample RSM and QCM for all repair stations. The examples included illustrate one of many possible ways to comply with the regulations.
1-2. THE MANUAL(S).
a. Combining Information. The applicant/certificate holder may combine portions required by part 145, § 145.209 with portions required by § 145.211 into one section or chapter of the manual system. For example, the procedures required in § 145.209 for RSM revision and the procedures required in § 145.211 for QCM revision could be combined into one chapter/section titled, “Manual Revision.” Additionally, the repair station may use applicable portions of its ISO manual or other quality system, such as ASQ, to show compliance with part 145.
b. Accessibility. The repair station’s manual(s) must remain current and be accessible to repair station personnel, as required by part 145 subpart D. The manual(s) may contain more procedures than required by the regulations for the certificate holder to describe the repair station’s overall functions, responsibilities, and quality control procedures. Procedures described in the manual(s) should ensure that the repair station could satisfactorily perform maintenance in accordance with (IAW) its rating(s). In that regard, a repair station with a Limited Specialized Service Rating would have different procedures in its manual system criteria than a repair station with a Class 3 Airframe Rating. Each manual system should be developed based on the repair station’s authorized ratings and the size and complexity of the repair station.
c. Checklist. The checklist in Appendix 2 may be used to assist the applicant/certificate holder in reviewing the content of its manual(s). All items listed on the checklist may not be applicable to each repair station due to differences in rating, size, and type of maintenance performed.
d. Submit the Manual. The applicant/certificate holder may submit the manual(s) to the FAA certificate-holding district office (CHDO) on paper or electronically. If the repair station submits the manual as part of an initial certification, the manual may be submitted together with related documents, such as the application form and repairmen applications, to the CHDO. If the repair station submits the manual electronically, they should discuss the format, software, and revision procedures with the CHDO before submittal. All submissions will require a cover letter. The repair station should follow the procedures described in its manual when submitting revisions to an existing manual (see Chapter 2, Manual Revision and Control).
e. Required Content. The basic regulatory requirements for manual content are listed below and will be discussed in detail in the following sections of this AC.
(1) RSM Elements.
(a) Manual Revision and Notifying the CHDO.
(b) Identification and Control of Sections of the Manual.
(1) RSM Elements. › (k) Required Records and Recordkeeping System.
(c) Organization Chart:
• Identify each management position
• The area of responsibility assigned to each management position
• Duties and responsibilities
(d) Rosters—Procedures for Maintaining and Revising.
(e) Description of Operations, Including the Housing, Facilities, Equipment, and Materials.
(f) Capabilities List—Procedures for (if applicable):
• Revision
• CHDO Notification
• Self-Evaluation Before Revision
• Methods
• Frequency
• Reporting Results
(g) Training Program—Procedures for:
• Revision
• Submitting to CHDO
(h) Procedures Governing Work Performed at Another Location.
(i) Procedures for Maintenance, Preventive Maintenance, or Alterations for Air Carriers.
(j) Contracting—Procedures for:
• Maintaining and revising the list of approved maintenance functions, including submitting revisions to the CHDO
• ct maintenance providers, including submitting revisions to CHDO
(k) Required Records and Recordkeeping System.
Maintaining and revising the list of contra
1-3. › a. Possible Combination. The following chart illustrates one of several…
(2) QCM Elements.
(a) Revision Procedures and Notifying the CHDO.
(b) Qualifying and Surveilling Noncertificated Persons Performing Maintenance, Preventative Maintenance, or Alteration for the Repair Station.
(c) Establishing and Maintaining Proficiency of Inspection Personnel.
(d) Establishing and Maintaining Current Technical Data.
(e) Inspection System:
• Incoming raw material inspection
• Preliminary inspection
• Hidden damage inspection
• Final inspection and return to service
(f) Calibration of Measuring and Test Equipment, Including Intervals of Calibration.
(g) Corrective Action.
(h) Samples of Inspection Forms and Instructions for Completion (may be a separate manual).
(3) Portions Recommended for Most Manuals.
(a) Table of Contents.
(b) List of Effective Pages.
(c) Record of Revisions.
1-3. COMBINING PORTIONS OF THE REPAIR STATION MANUAL WITH THE QUALITY CONTROL MANUAL.
a. Possible Combination. The following chart illustrates one of several possible combinations that applicants/certificate holders could use to structure a single manual system. It includes the procedures required in both the RSM and the QCM. Other combinations may be possible depending upon the ratings, size, and complexity of the repair station. The manual’s content must include the applicable procedures required by the regulations, but may be formatted in any manner easily understood by employees of the repair station.
NOTE: A part 145 repair station that also holds an air carrier certificate may refer to sections of its air carrier approved maintenance program in its
e. Section Control. The procedures to control sections of the manual… › (4) Issue date.
part 145 manuals. If the manuals are structured in this manner, those sections must adhere to part 145 regulatory requirements. The affected sections would apply to aircraft listed on the air carrier OpSpecs or to other third party air carriers or aircraft owners that are serviced by the certificate holder.
b. Meeting the Requirements. The repair station should include a table to show the FAA that its manual system meets the requirements of §§ 145.209 and 145.211.
1-4. IDENTIFICATION AND CONTROL OF SECTIONS.
a. Page Numbering. Sequential numbering of the manual(s) from front to rear may cause difficulty for the revision process. A minor revision to one of the first pages may cause a change in the content of each successive page. The FAA advises the repair station to divide the manual into several sections, so that a revision to one page of a section does not affect the entire manual.
b. Related Subject Matter. Most RSMs are divided into sections of similar subject matter. For instance, one section of the manual may contain all of the procedures related to the inspection system. The repair station may establish these sections or the sections may be contained within an established industry format (such as ISO). The sample formats included in this chapter contain a few examples of the many possible methods used for identification. The sections may consist of several similar individual procedures grouped together through a common numbering system, or several similar procedures described in narrative format within a section. Regardless of the method used, each section must be identified and controlled.
c. Table of Contents. Many RSM sections are controlled using a table of contents. The table of contents lists each section of the manual and the location in the manual. Some repair stations choose to reissue a complete section of the manual if any page within that section is revised. The table of contents for those facilities may indicate revision status for each section, rather than each page.
d. Master Document Control List. Some RSMs are controlled using a master document control list. This document lists each procedure and the revision status of that procedure. A unique number and revision status should identify each procedure within the manual system. If a page within a procedure is revised, the entire procedure is reissued. In this system, each procedure is identified and controlled, rather than each section.
e. Section Control. The procedures to control sections of the manual should address (as applicable):
(1) Identification.
(2) Revision status.
(3) Page numbering.
(4) Issue date.
1-1. PURPOSE. › 1-5. SAMPLE PROCEDURE FORMATS.
(5) Approvals of internal personnel responsible for the manual and revisions.
EXAMPLE.
Repair Station Manual
Element + Quality Control Manual
Element = Possible Chapter/Section Title
Training program, revision, notifying CHDO +
Establishing and maintaining proficiency of inspection personnel
=
Training
Maintaining and revising contract information + Qualifying and surveilling noncertificated persons = Contracting
Manual revision, CHDO notification, identification, and control of sections
+
Manual revision and CHDO notification =
Manual Control
Records and recordkeeping system +
Establishing and maintaining current technical data
=
Document Control
Etc. + Etc. = Etc.
f. Additional Combinations. Additional combinations that work effectively within the facility and are acceptable to the FAA principal inspector (PI) may be included in the manual system.
1-5. SAMPLE PROCEDURE FORMATS. The following samples are provided to help the manual writer determine a possible format for the procedures in the manual system. These are only four examples of many possible formats. Part 145 sets the requirements for content, not format. The format used for the procedures in the manual should fit the size and complexity of the facility. If there are existing procedure manuals in the facility, the manual writer may wish to include the same format in the RSM(s). If facility employees are accustomed to a particular format, the manual writer should continue to use that format.
(1) Advantages. › (2) Disadvantages.
SAMPLE PROCEDURE FORMAT 1
Section: 5
Page: 3 John Smith Component Repair, Inc.
Revision: 1 123 Any Street Date: 11/14/2001 Somewhere, CT 12345
PRELIMINARY INSPECTION
The Chief Inspector (WHO) of the repair station is responsible for the performance of appropriate inspections, including functional and nondestructive tests. This inspection will be conducted on the hangar floor or in the inspection area (WHERE) for components. This will ensure that all units (WHAT) delivered to the repair station for maintenance are inspected to determine the state of preservation and any defects. This inspection will be recorded on the Preliminary Inspection Form 567 (RECORD) with any discrepancies noted. The form must be attached to the work order and will remain with the applicable inspection records until the unit is released for service. Forms 123 and 789 will be used to record the results of the functional and nondestructive tests. Those forms will show the work order number and will be routed, attached to the work package.
HOW
a. Format Discussion.
(1) Advantages. Format 1 includes each of the required elements of a procedure in a narrative format. This format is easy to write, as long as the author remembers to include all of the elements. This format is usually easy for the reader to understand and requires no special training for the author or reader.
(2) Disadvantages. The narrative can easily become too complex or wordy. The author may fail to include all of the required elements of the procedure. The narrative must be presented in a logical sequence so the reader can easily understand the flow of the procedure.
a. Format Discussion. › b. Format Discussion. Format 2 assigns responsibility as part of each…
SAMPLE PROCEDURE FORMAT 2
THE JOHN SMITH COMPANY OPERATING PROCEDURE 123
Title: Receiving Inspection Page 1 of 4
Revision: A Issue Date: November 12, 2001
----------------------------------------------------------------------------------------------------------
Reason: To ensure consistent quality of incoming raw material.
Scope: Applies to all raw material shipments received. This procedure does not apply to incoming parts received for repair.
Responsibility: The receiving inspector is responsible for inspecting all incoming raw materials.
Procedure:
1. The receiving inspector will visually inspect the container (if used) and/or material for any shipping or handling damage.
2. The receiving inspector will immediately report any shipping or handling damage to the purchasing department.
3. Compare the purchase order (copy located in receiving file) with the shipping document to ensure the material is correct.
4. Etc.
b. Format Discussion. Format 2 assigns responsibility as part of each procedure. The narrative should be written in a format easily understood by the person who uses and must follow the procedure. Note that the format also includes revision status, issue date, and page numbering. The reason and scope may be used to state the company policy or objective.
a. Format Discussion. › a.
SAMPLE PROCEDURE FORMAT 3
John Smith Overhaul & Repair
Quality Procedure—Control of Inspection, Measuring, and Test Equipment
QP 4.11
Approval Approval Revision/Date Reason for Change
John Smith, Sr. Jane Doe Original—04/01/2000 Original issue
John Smith, Sr. Jane Doe A—06/15/2000 Added gage request form
1.0 Purpose: To ensure that all precision tools and equipment are properly calibrated, identified, and maintained.
2.0 Scope: This procedure applies to all employees who use inspecting, measuring, and testing equipment, and those who calibrate that equipment.
3.0 Responsibility: The Director of Quality is responsible for ensuring that all inspecting, measuring, and testing equipment is calibrated and traceable. Only trained and qualified personnel are permitted to adjust and calibrate equipment.
4.0 Reference Documents:
4.1 QAP 15.0, Inspection and Test Status 4.2 MIL-STD-120 Gage Inspection 4.3 Work Instruction (WI) 4.11-1 through WI 4.11-20
5.0 Definitions:
5.1 Accuracy of Measurement: The closeness of the agreement between the result of a measurement and the conventional true value of the measurement. 5.2 Uncertainty of Measurement: The result of the evaluation aimed at characterizing the range within the true value of a measurement. It’s estimated to lie generally within a given likelihood. 5.3 Etc. 5.4 Etc.
6.0 Procedure:
6.1 The gage calibration technician will maintain a computerized list of all precision tools and equipment using the Gage Control software program. 6.2 During the first week of the month, the gage technician should run the “Calibration Required” report, listing all tools and equipment that must be calibrated before the end of the month. 6.3 The gage calibration technician will issue a John Smith Recall Slip (Form 789) to the department or individual. This form states which tools are due for calibration and the date they must be returned to the tool crib. 6.4 Etc.
7.0 Records:
7.1 Form 789, Recall Slip 7.2 Form 456, Record of Calibration 7.3 Form 123, Identification Sticker 7.4 Etc.
a. Format Discussion. › e. Format Discussion. Format 4 requires the reader to have some…
c. Format Discussion. Format 3 is often used for procedures included in an ISO 9000 quality system document. Note that space is provided to document approval and release of the document (part of a document control system). Terms used within the procedure are defined. Additional documents associated with this procedure are listed. The format is structured— perhaps too structured—for some organizations. The procedure follows a standard numbering system for each portion of the procedure, allowing for precise reference for paragraphs that may be discussed or revised. Work instructions and records may follow the same numbering convention (i.e., QP 4.12, WI 4.12-1, and Form 4.12-A). Forms may be included within the procedure or in a separate forms section of the manual system.
d. Sample Procedure Format 4 Introduction.
(1) The following flowchart illustrates another possible method of presenting a procedure. Although the sample illustrates a simple procedure, complex processes could be presented using a flowchart. The person using the manual would need to be familiar and comfortable with flowcharts and flowchart symbols.
(2) The flowchart process may also be used to develop a procedure that was not previously documented. The procedure could be initially drawn on paper using a flowchart, and then described using the narrative format in the manual. This process works well when the users of the manual are more comfortable with narrative procedures rather than flowcharts.
(3) Another possible use of the flowchart is to verify if a narrative procedure will work. This process is essentially the opposite of the process previously described. While reading the narrative of the procedure, a flowchart is created to visually represent the various steps. A review of the completed flowchart will show any redundant or missing steps.
(4) A flowchart can also be used during a process audit. The auditor creates a flowchart while reviewing the performance of a particular process. The auditor then compares the process he or she observed with the process described in the manual. Any differences may be noted in the auditor’s report.
e. Format Discussion. Format 4 requires the reader to have some familiarity with flow charts, but can be easily understood by someone who understands the format. Because the flow charts contain fewer words than other formats, the process can be read and understood quickly. This format takes longer to develop unless the author has specific software for the purpose.
4. DEFINITION OF TERMS. › Chapter 1.
SAMPLE PROCEDURE FORMAT 4 (Continued)
Section: 5
Page: 3 Revision: 1 Date: 11/14/2001
Yes
Move to material cage
Release
form
Acceptable? Forward
to QC
Form
789
See material
review
QP
No
No
Return to
vendor
Form
456
Yes Damage acceptable?
Compare shipper to
purchase order and
specification
Determined
by QC Manager
Visually inspect container/material Damaged?
Notify Purchasing and Quality Control
Manager
Yes
No
Form
123
e. Procedures. Regardless of the media used for the manual, the… › (4) How will the repair station correct any maintenance/administrative…
CHAPTER 2. MANUAL REVISION AND CONTROL
2-1. PROCEDURES FOR REVISION.
a. References:
• Section 145.211(c)(4), and
b. Requirements. The RSM and the QCM must contain procedures for revising the manual(s) and notifying the CHDO of revisions.
NOTE: The regulations do not require FAA review and acceptance of revisions before implementation, provided the repair station follows the revision procedures in its manual. The repair station should have a procedure in its manual to recall revisions if the FAA finds a revision unacceptable.
c. Control Submissions and Revisions. This section of the manual must contain procedures to control the original submission of the manual and subsequent revisions. The procedures should ensure that persons issued a manual receive revisions. Repair station employees may require training on the content of the revisions, especially if a standard operating procedure or inspection procedure is changed.
d. Describe Control System. The manual must include a description of the system used to identify and control sections of the manual. The format and structure of this system is not specified by the regulation. This flexibility will accommodate the technological changes that permit repair stations to maintain and revise the manuals in different formats and manners.
e. Procedures. Regardless of the media used for the manual, the procedures for making revisions should include:
(1) Who, by title, is responsible for making revisions?
(2) Who will submit revisions to the FAA for review and acceptance?
(3) How will the repair station incorporate changes to revisions found not acceptable to the FAA, which do not conform to applicable regulations?
(4) How will the repair station correct any maintenance/administrative actions performed under revisions that were found not acceptable to the FAA?
a. Network. If the manual is maintained on a network server, the… › (3) Revisions—How will the user know that the manual has been revised,…
(5) How will the revisions be distributed and made available within electronic systems, and how will the FAA receive its revisions?
(6) Accountability—how will the facility ensure that each manual holder or designated location receives each revision?
(7) Identification of each revision to the text on each affected page. For example, a vertical bar in the margin or other suitable method may indicate the revised portion of text.
2-2. PROVISIONS FOR CONTROL. If the manual is in paper format, the revision and control part of the manual should contain the following (or equivalent) information:
a. Revisions. Procedures for revising the RSM and notifying its CHDO of revisions, including how the FAA will be notified of revisions.
b. Details. Provisions for selecting the revision number, the date of the revision, the pages revised, and a place for the person making the revisions to the assigned manual to sign or initial.
c. Manual Control Number and Assignment. Each manual should have a unique number assigned to it and the name of the individual, department, or group assigned to that particular manual. The manual procedure should identify who will maintain a master distribution list that contains the manual number, assigned individual, and revision status.
NOTE: An acknowledgement form is a common method of tracking the receipt and insertion of the revision by the manual holder, which ensures accountability. With this method, after receiving a revision, each manual holder inserts the revised pages into the manual, records incorporation of the revision in the record of revisions, and returns the signed acknowledgement form to the person responsible for manual control.
2-3. ELECTRONIC FORMAT. The manual(s) may be maintained on a computer network or other electronic medium. AC 120-78, Acceptance and Use of Electronic Signatures, Electronic Recordkeeping Systems, and Electronic Manuals, provides additional guidance for electronic systems.
a. Network. If the manual is maintained on a network server, the following concerns must be addressed in the procedures:
(1) Security—How will the repair station ensure that only authorized personnel make any changes? Who (by title) will be authorized to make those changes and how is that person authorized?
(2) Access—Have the employees been trained to access the manual on the network? Is access protected by passwords? Do all of the supervisors and inspectors have access to the manual?
(3) Revisions—How will the user know that the manual has been revised, and the content of that revision?
4. DEFINITION OF TERMS. › Chapter 1.
(4) Availability—How will the repair station ensure that the current manual(s) are available for all shifts?
b. Disk. If the manual is maintained on a disk, the following concerns must be addressed in the procedures:
(1) How will the manual and any subsequent revisions be distributed? How will receipt of the revision be documented?
(2) Is the software used for writing the manual compatible with the software used by all manual holders, including the FAA?
(3) Are all of the manual holders trained on the procedures necessary to access the manual at their workstations?
(4) How can station personnel verify if the disks are current before they use them?
NOTE: Federal law prohibits agencies from making the use of electronic media more difficult or from requiring additional steps or procedures for users of electronic media. Therefore, all repair station document submissions, regardless of the media used, must be accompanied by a cover letter that describes the submission and is signed by an appropriate manager. FAA inspectors will either accept or reject the manual revision. The FAA inspector will, by letter, inform the repair station of acceptance or rejection. The letter will address the manual title, manual date, and revision number. If the manual is rejected, the FAA inspector will provide a detailed explanation of the deficiencies and advise the repair station not to perform maintenance if the rejected manual procedures are in use.
Par 2-3 Page 13 (and 14)
c. Procedure Details. Ensure that the following concerns are addressed… › (4) Is an accountable manager designated?
CHAPTER 3. REPAIR STATION ORGANIZATION CHART
3-1. ORGANIZATION CHART.
a. Reference. Section 145.209(a).
b. Authority. The organization chart identifies (by title only) each management position with authority to act on behalf of the repair station. If the repair station performs work for air carriers or air operators under part 145, § 145.205, and is performing RII, the FAA suggests that the chart reflect the separation between the maintenance and inspection departments.
EXAMPLE EXAMPLE
Complex Repair Station Small Repair Station
c. Procedure Details. Ensure that the following concerns are addressed in the manual procedures.
(1) Are the titles and reporting structure for the organization chart appropriate for the facility?
(2) Are the titles for the positions the same throughout the manual?
(3) Is each management position with authority to act on behalf of the repair station identified?
(4) Is an accountable manager designated?
General Manager
Repair Station
Manager
Machinist
Supervisor/
Repairman
Shipping/ Receiving
Quality Manager/Accountable
Manager
President
Human Resource
Manager
Purchasing Comptroller
Inspectors
Chief Inspector
Owner/President Accountable Manager
Technician
Chief Inspector
3-2. DUTIES AND RESPONSIBILITIES.
a. Organization. This section may be combined with the organization chart as one section/chapter of a manual system. If the repair station documents its procedures in a format that includes a Responsibility section in each procedure, it will not need to have a separate Duties and Responsibilities section (see Chapter 1, Sample Procedure Formats 2 and 3).
3-2. DUTIES AND RESPONSIBILITIES. › c. Additional Responsibilities. Duties and responsibilities that are…
b. Area of Responsibility. This section includes the area of responsibility assigned to each management position and the duties, responsibilities, and authority of each management position. The repair station must ensure that the duties and responsibilities are appropriate and that the positions exist within the company. Although not required by the regulation, many repair stations choose to include duties and responsibilities beyond the required management personnel. Positions described in the organizational chart should be included in the duties and responsibilities section to ensure consistency.
c. Additional Responsibilities. Duties and responsibilities that are outside the scope of the management, but are part of the regulatory requirements, should be described in this section of the manual. For example, equipment maintenance, approval for return to service, applications for repairmen, and so forth.
NOTE: Only titles, not names, should appear in this section. Titles should be the same as on the organization chart and elsewhere in the manual.
NOTE: Titles used in the following format samples are only examples.
SAMPLE: NARRATIVE FORMAT.
Owner/President: The Owner/President is responsible for the overall operation of (name of the repair station) in accordance with the applicable CFRs. The Owner/President’s duties include maintaining an adequate and knowledgeable staff to plan, perform, supervise, and inspect the work being performed on civil aviation articles. The Owner/President may delegate all duties to the qualified persons as necessary. However, such delegation does not relieve the Owner/President of the overall responsibility.
4. DEFINITION OF TERMS. › Chapter 1.
SAMPLE: OUTLINE/LIST FORMAT.
Quality Manager: The Quality Manager reports to the President and is responsible for managing the repair station quality control system. The duties of the Quality Manager include:
(1) Supervising all inspection personnel. (2) Maintaining a current file of pertinent technical data, including CFRs,
specifications, manufacturer’s maintenance manuals, service bulletins (SB), Airworthiness Directives (AD), and other data acceptable to or approved by the FAA. (3) Ensuring the proper execution of FAA Form 337, Major Repair and Alteration
(Airframe, Powerplant, Propeller, or Appliance), when required. (4) Etc.
SAMPLE: ISO/INDUSTRY FORMAT.
The duties and responsibilities may be addressed in the management responsibility section of the manual (i.e., section 4.1).
a. The following questions or concerns are offered as a guide and are intended to help the facility initiate the procedures in its RSM. They should not be considered all-inclusive. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and the needs of the repair station.
(1) Do the duties and responsibilities include the areas of responsibility assigned to
each management position?
(2) Do the duties and responsibilities indicate the reporting structure (to what other
position does each report)?
(3) Does the narrative describe the job function(s) that person performs (i.e.,
calibration, training, personnel management)?
(4) Do the procedures ensure that the duties and responsibilities of supervisory and
inspection personnel are performed in their absence?
(5) Does the manual have a procedure to determine if a supervisor or inspector is
qualified for any delegated duties?
b. Consider the following when assigning duties and responsibilities within the repair station:
(1) Is each supervisor certificated?
(2) Do the inspectors understand, read, and write English?
(3) Are persons with approval for return to service authority certificated?
Par 3-2 Page 17 (and 18)
CHAPTER 4. REPAIR STATION AND QUALITY CONTROL MANUAL ELEMENTS
4-1. REPAIR STATION PERSONNEL ROSTER.
a. References:
• Section 145.161, and
g. Roster Procedures. The following questions should be answered during… › (2) Where will the rosters be located?
b. Authorized Personnel. Personnel rosters are lists of individuals within the repair station who are authorized to perform certain functions, such as approval for return to service or signing off required inspection items, or that hold certain management and supervisory positions. These lists can be maintained in paper or electronic format, but must be accessible for review and inspection by the FAA.
c. Roster Format. The repair station must maintain a personnel roster or rosters that list managers, supervisors, inspectors, including RII inspectors, and those individuals authorized to approve an article for return to service. Each repair station may develop its own roster format, as long as it contains all of the appropriate names.
d. Manual Inclusion. The rosters do not need to be included in the manual, but the procedures for maintaining and revising the rosters must be in the manual. If the rosters are not included in the manual, the procedure should describe where the rosters would be located. The procedure must describe how the roster will be changed within 5 business days of the termination, reassignment, change in duties or scope of assignment, or addition of any personnel.
e. Combination Roster. It may be appropriate for the repair station to develop a combination roster, which would include initials, signatures, stamp numbers, certificate numbers, or any other information used to designate the authority of inspection or supervisory personnel who can sign/stamp off work documents or approve articles for return to service.
f. Employment Summaries. The repair station must also maintain employment summaries for each person whose name appears on the rosters. Employment summaries of supervisors, inspectors, and persons responsible for return to service may be in the national language for repair stations located outside the United States. Such repair stations should describe in their manuals how they would provide the FAA with an English version of employee summaries. The requirements for content of the employment summaries are found in § 145.161(a)(4).
g. Roster Procedures. The following questions should be answered during development of the procedures concerning the rosters:
(1) Who is responsible (by title) for maintaining the rosters in current condition? Has an alternate been designated?
(2) Where will the rosters be located?
a. References: › h. Examples. The following are examples of possible roster formats.
(3) How will the rosters be revised within 5 business days?
(4) Is authority to approve an article for return to service shown on the rosters? Who is responsible for designating those individuals, and how are those individuals designated?
(5) Are the managers, supervisors, inspectors, and persons authorized to approve articles for return to service all listed on the rosters?
(6) Are the supervisors certificated, and with what type of certificate if located outside the United States?
(7) Are the persons authorized to approve articles for return to service certificated? (Each person authorized to approve articles for return to service must be certificated under part 65, unless located outside the United States.)
(8) Are there employment summaries for each person on the roster?
h. Examples. The following are examples of possible roster formats.
EXAMPLE 1
Name and Title Certificate
Type and
Number
Signature and
Initials
Stamp Authorization
John Smith Chief Inspector
A&P 12345678 A, B, C 2 JOHN SMITH, JS
Jane Doe Receiving Inspector
Repairman 789654321 B 4 Jane Doe, JD
David Goodeye Final Inspector
Repairman 456789123
A, C
Etc.
6 David Goodeye, DG
Explanation of Authorization:
A—Authorized to approve articles for return to service B—Authorized to sign for a specific inspection C—Authorized to sign for in-process and final inspection
EXAMPLE 2
Section: III Date Completed: 11/13/2001
4-2. OPERATIONS, HOUSING, FACILITIES, EQUIPMENT, AND MATERIALS. › c. Housing and Facilities. This section should include a description of…
Revision No. 1 Personnel
Title: Chief Inspector/Repairman
Authorized Signature: Kyle R. Bowman
FAA Airman Certificate Held: Repairman No. 123456789
Authorized to Sign: Log books and other approvals for return to service, Malfunction and Defect Reports
EXAMPLE 3
John Smith Component Repair, Inc.
Effective Date: 11/13/2001 Supervisory and Inspection Personnel Roster
TITLE NAME CERT. TYPE & NO. AUTHORITY CEO John Smith N/A N/A Q.C. Manager Jane Smith Repairman 1234567 FPI, Machining Foreman Dan Jones Repairman 98765432 Machining, Cleaning Chief Inspector David Jones N/A N/A
4-2. OPERATIONS, HOUSING, FACILITIES, EQUIPMENT, AND MATERIALS.
a. References:
• Part 43, and
• Sections 145.101 through 145.109.
b. Operations. This section of the manual should include a general description of the repair station operations. The manual should describe how the repair station operates, from receiving an article for maintenance to approval for return to service. The description could be in a narrative, flowchart, or other format. Any/all standard operating procedures developed for the facility could be included, such as contract/purchase order review, human resources, equipment and facilities maintenance, technical data, document control, and so forth.
c. Housing and Facilities. This section should include a description of the housing and facilities, and a drawing showing the floor plan of the facility. The drawing could include the entrance(s), parking areas, and street locations. The drawing and description may include the type of heating, lighting, equipment location, shop areas, electrical, and compressed air outlets.
e. Equivalent Tools and Equipment. › (1) If the repair station will be using equipment, tools, or materials…
A description of any facilities used for spray painting, avionics, engine or airframe repair, or any other work that would have special requirements should be included.
d. Equipment and Materials.
(1) The repair station must have the equipment, tools, and materials necessary to perform the maintenance in accordance with part 43. The equipment, tools, and materials must be located on the premises and under the repair station’s control when the work is being done. Some of this equipment may be very expensive and the repair station may rarely use it. If the repair station does not own the equipment and it is not kept at the facility, the manual must describe how the equipment is obtained (i.e., lease, rental, etc.). The manual should also describe the procedure for ensuring the equipment is on the premises and under the repair station’s control at the time the work is being performed.
(2) This section of the manual should also describe where the equipment is likely to be used and how the repair station will comply with special handling requirements for sensitive tools and equipment. Some test benches and special equipment may require calibration/verification after relocation. This section of the manual should describe how the repair station ensures that required calibration/verification is performed before using the equipment to perform maintenance or alteration on civil aviation articles. The RSM should identify which department is responsible for calibrating leased tools and equipment.
(3) The RSM must include a description of the equipment used to perform maintenance. For example, if the facility includes a machining area, then a generic description of the types of machines located in that area should be included in the manual. The description should not be so specific that updating equipment would result in a manual revision. The equipment, tools, and materials must be those recommended by the manufacturer of the article or must be at least equivalent to those recommended by the manufacturer and accepted by the FAA. The repair station may refer to a list of equipment maintained for other purposes, such as a list kept by the accounting department for tax purposes. The list must be available for review by the FAA. The list need not include the cost of the equipment or any other financial or business information.
e. Equivalent Tools and Equipment.
NOTE: This section is not intended to discuss industry standard tools and equipment (i.e., wrenches, multimeters, sockets, etc.) that are manufactured to a recognized industry standard.
(1) If the repair station will be using equipment, tools, or materials other than those recommended by the manufacturer, the manual must explain the procedure it will use for determining equivalency of equipment, tools, and materials. To determine equivalency, compare the technical requirements of the special equipment or test apparatus recommended by the manufacturer with the proposed replacements. The equipment or test apparatus may look different, be made of different materials, be a different color, and so forth. However, the equipment or test apparatus must be capable of performing all necessary tests and checking all required parameters of the articles. The level of accuracy should be equal to or better than that
4-3. CAPABILITY LIST. › a. References:
recommended by the manufacturer of the equipment/tools. Reverse engineering must include the data, drawings, testing, or reports necessary to determine that the article is equivalent to the article recommended by the manufacturer. The basis of equivalency is the requirement that the article meet the manufacturer’s standards and specifications in all respects regarding tolerances, repeatability, and accuracy. Repair stations should review the specific requirements of part 43 before developing equivalent tools and equipment.
(2) Standard industry practice establishes that each piece of special equipment or test apparatus have a unique part number and serial number to identify it within the repair station’s inventory system. Whether the equipment or apparatus is obtained from the manufacturer or produced by the repair station, it should be identified in the system for calibration and tracking purposes.
(3) The following questions or concerns are offered as a guide and are intended to help initiate the procedures for describing the housing, facilities, and equipment in the manual(s). They should not be considered all-inclusive. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and needs of the repair station.
(a) Does the manual include a description of how the repair station operates?
(b) Does the manual include a drawing of the housing, identifying the various work facilities within the building(s) and giving a narrative description of the construction of the housing and facilities?
(c) Does the description and/or layout identify areas with special requirements?
(d) Does the description include a generic overview of the equipment?
(e) When leasing or renting equipment, does the manual contain procedures describing the lease/rent process and who is responsible for managing the program, including the required calibration/verifications?
(f) How does the repair station ensure that the equipment is in place and under the facility’s control when the work is performed?
(g) If the repair station is using special equipment or tools other than those recommended by the manufacturer, does the manual include procedures for determining equivalency?
(h) Does the manual include a description of the stock room/area, how inventory is requisitioned for particular jobs, and how shelf life inventory is maintained?
4-3. CAPABILITY LIST.
a. References:
• Section 145.209(d), and
(2) The individual should follow the procedures in the RSM, using the… › (d) Current technical data.
b. Capability List. A certificated repair station with a limited rating may perform maintenance, preventive maintenance, or alterations on an article if it is listed on a current capability list acceptable to the FAA or on the repair station’s OpSpecs. If the repair station chooses to use a capability list, the RSM must:
(1) Contain procedures for revising the list and notifying the CHDO;
(2) Include how often the CHDO will be notified of revisions;
(3) Contain the procedures for the self-evaluation required under § 145.215(c) for revising the capability list;
(4) Describe the methods and frequency of such evaluations; and
(5) Contain the procedures for reporting the results to the appropriate manager for review and action.
c. Revising the List. The capability list itself may be included as a part of the RSM or as a separate document; however, the procedures for revising the list and for performing the self-evaluation must be in the manual.
d. Self-Evaluation.
(1) The individual performing the self-evaluation required under § 145.215(c) should have the following qualifications:
(a) Experience with performing evaluations (or audits if that is the method selected by the repair station).
(b) An understanding of the requirements of part 145.
(c) Knowledge of the maintenance requirements for the particular make/model of article to be added to the list.
(2) The individual should follow the procedures in the RSM, using the checklists, working documents, and forms to record the self-evaluation. The checklists and forms may need to be customized for each self-evaluation. The self-evaluation should ensure that the repair station has the following:
(a) The appropriate limited rating.
(b) Adequate housing and facilities.
(c) Recommended tools, equipment, and materials, or equivalent.
(d) Current technical data.
4-3. CAPABILITY LIST. › j. Procedures Guide. The following questions or concerns are offered as…
(e) Sufficient qualified personnel.
e. Record and Report the Results. The individual conducting the self-evaluation must record the results and report them to the appropriate manager or management team for review and approval. The procedures should describe the acceptance process for the company officials and the FAA. The procedure used to revise the list should describe the method used to indicate any changes made to the list. Any deficiencies found during the self-evaluation must be corrected before the article can be added to the capability list. When the self-evaluation establishes satisfactory results, the capability list may be revised. The repair station should keep records of the self-evaluation on file for the period specified in the manual. For repair stations located outside the United States, the records of the self-evaluation may be in the national language, however, they must be made available to the FAA in English.
f. Person Responsible for Maintaining the List. The procedures for revising the list and notifying the CHDO should include the title of the person responsible for maintaining the list and communicating any revisions to the CHDO. If the self-evaluation was satisfactory, the capability list may be revised. The revised list and any other necessary technical data can be submitted with a cover letter to the PI at the CHDO within 5 business days. The PI will review the revisions and, if the revisions are satisfactory, signify acceptance by signing and dating the appropriate document.
g. List Currency. Capability list currency can be shown by a list of effective pages or equivalent document, which is signed by the authorized representative of the repair station and the FAA PI.
h. Deleting Articles. If the repair station no longer wishes to maintain an article on its capability list, the article should be deleted. The repair station must have the necessary tools, equipment, housing, facilities, and trained personnel to maintain articles on the capability list at the time the work is performed. The procedures in the manual should describe how to delete articles from the list and how to forward the revised list to the FAA for acceptance. The repair station may choose to audit the capability list on a regular basis to ensure that it continues to have the housing, facilities, equipment, and technical data that meet all necessary requirements to maintain the articles listed in the document. Whenever equipment, tooling, personnel, and data must be obtained in order to perform the maintenance or alteration on an article that is going to be added to the capabilities list, the repair station must explain how it will ensure these items will be available when the work is being performed.
i. Electronic Media. If the capability list is maintained on electronic media, the repair station will need to work with the CHDO to ensure compatibility of the media, equipment, and software with that of the CHDO. Revision procedures will need to address documentation of approval by the company as well as acceptance by the FAA.
j. Procedures Guide. The following questions or concerns are offered as a guide and are intended to help initiate the procedures in the manual. They should not be considered all-encompassing. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and the needs of the repair station.
4-4. TRAINING PROGRAM REVISION. › e. Frequency of Review. The procedures should address how often the…
(1) What is the title of the person who will maintain the capability list?
(2) How will the self-evaluation be performed?
(3) Who will perform the self-evaluation?
(4) How will the self-evaluation be documented?
(5) How will results of the self-evaluation be reported to management and how will management review the addition of capabilities to the list?
(6) How will items be added to and deleted from the list?
(7) How are changes clearly indicated on the document?
(8) If electronic media is used, is the hardware and software compatible with that of the CHDO?
(9) Where and by whom will self-evaluation reports be maintained?
(10) How long are self-evaluation reports maintained?
4-4. TRAINING PROGRAM REVISION.
a. References:
• Section 145.163, and
b. Chapter Information. Repair stations developing a training program may use the information in this chapter as a reference. AC 145-10, Repair Station Training Program, provides additional information on developing the repair station employee training program required under § 145.163.
c. Required Procedures. The RSM must include procedures required by § 145.163 for revising the training program. It must also include procedures for submitting those revisions to the CHDO for approval.
NOTE: Repair stations located outside the United States should submit the repair station training program in the English language.
d. Responsibility for Revisions. The procedures should address who will be responsible for ensuring that revisions are submitted to the PI at the CHDO for review and approval. The procedures should include instructions for approval by the repair station before submission to the FAA, as well as provisions for the FAA PI’s approval of the program and its revisions.
e. Frequency of Review. The procedures should address how often the program will be reviewed to determine if it is current and adequate for the type of maintenance being performed
4-5. WORK PERFORMED AT ANOTHER LOCATION. › b. Special Circumstances. The rule permits a repair station to perform…
at the facility. Because the advancements in technology can cause aviation maintenance to change rapidly, a periodic review of training needs would be appropriate. Repair stations that have established a management review program should include the training program for review during that meeting.
f. Training Program. The training program may be documented as a section of the RSM, or as a separate document within the manual system. If the training program is a separate document, that document will need to include the procedures for submission to and approval by the FAA.
g. Training Program Guide. The following questions or concerns are offered as a guide and are intended to help the repair station initiate the procedures in its manual(s). They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the needs of the repair station.
(1) Who is responsible for submitting the initial training program and its revisions to the FAA?
(2) When will the revision be submitted?
(3) How will the revision be approved (include the company approval as well as FAA)?
(4) How often will the training program be reviewed for currency and completeness?
(5) Who will perform the review?
(6) How will revisions be recorded and implemented?
(7) How will the revised text be identified?
4-5. WORK PERFORMED AT ANOTHER LOCATION.
a. Reference. Section 145.203.
b. Special Circumstances. The rule permits a repair station to perform work away from its fixed location on a temporary basis. When a special circumstance arises, or it is necessary to perform such work on a recurring basis. Section 145.203(a) permits temporarily working away from the repair station’s fixed location due to a special circumstance, as determined by the FAA. Examples would be an aircraft on the ground or in preparation for a ferry flight. Normally work performed at another location does not include working outside the country where the repair station is located. However, work performed outside the country under a special circumstance may be authorized under § 145.203(a). If work must be performed outside the country, the repair station should obtain required approvals from the country where the work will be performed. The RSM will need to include a procedure on notifying the local CHDO when these special circumstances arise in order to obtain the FAA’s approval in each instance. A manual procedure for the work performed will not be necessary. The RSM procedures should address the following:
c. Recurring Work. Section 145.203(b) permits work away from a repair… › (9) Who is responsible for transporting and storing the records?
(1) The method used for identifying the customer and describing the work requested or anticipated, the location at which the work will be performed, the type of material, equipment, and personnel that will be required to perform the anticipated work, the way the material, equipment, and personnel will be transported, and the precautions that will be taken to ensure that the material and equipment are adequate for the work that actually needs to be performed.
(2) The title of the person who will notify the CHDO.
(3) How the notification will be made.
(4) How the approval/denial will be recorded and stored.
c. Recurring Work. Section 145.203(b) permits work away from a repair station’s fixed location when it is necessary to perform such work on a recurring basis, such as a repair station that performs fuel tank maintenance and the work can only be performed on the aircraft away from the repair station’s fixed base, or the installation of aircraft seats after refurbishment. These are examples only; other repair stations may have their own unique circumstances that require performing maintenance away from their fixed base. A manual procedure for work performed is required if the repair station performs work at another location on a recurring basis. The RSM must include procedures for accomplishing maintenance, preventive maintenance, alterations, or specialized services at a place other than the repair station’s fixed location. This business practice will provide flexibility and mobility to meet industry needs and not be restricted “only” to special circumstances. The manual procedures should address the following:
(1) Describe the preparations and conditions to be met before performing any work away from the repair station.
(2) Who is responsible for supervising the maintenance performed at another location?
(3) Are the appropriate sections of the RSM available at the remote site?
(4) How does the facility ensure that adequate housing, facilities, tools, equipment, personnel, and current technical data are available at the site? If materials, tools, and equipment must be transported, how will their calibration be ensured?
(5) Does an individual certificated under part 65 supervise the work of persons unfamiliar with the work to be performed?
(6) When and how is the article inspected? Is the inspector qualified and authorized (on the roster)?
(7) How is the work recorded? Do the records meet the requirements of part 43, § 43.9?
(8) Are the forms at the repair station the same as those used at the other location?
(9) Who is responsible for transporting and storing the records? Where will they be stored?
4-6. › c. Identify Responsibilities. The procedures should identify who is…
(10) How does the facility ensure that each location stays in compliance with its manual and part 145?
NOTE 1: The rule does not allow continuous, uninterrupted operations at another location without applying for a repair station or satellite certificate at that location.
NOTE 2: A combination of storing equipment, tools, parts, etc., and having repair station personnel permanently positioned at a site and performing maintenance on a daily basis away from its permanent fixed base indicates a continuous, uninterrupted operation. A repair station that operates in this fashion no longer meets the intent of § 145.203. If the repair station is to continue its operations in this manner, then it must apply for certification as a satellite or stand-alone repair station.
d. Permanent Fixed Location. Additionally, work that is to be performed at another location does not include other authorizations, such as having a line maintenance authorization to perform work for an air carrier. Work performed at locations away from their fixed base allows repair stations the flexibility to meet industry needs and to be mobile when necessary. Repair stations must still maintain a permanent fixed location even if the majority of their work is done at another facility.
4-6. MAINTENANCE, PREVENTIVE MAINTENANCE, AND ALTERATIONS PERFORMED FOR AIR CARRIERS UNDER PARTS 121, 125, 129, AND 135.
a. Reference. Section 145.205.
b. Requirements. Some repair stations perform maintenance, preventive maintenance, or alterations for air carriers conducting operations under parts 121, 125, 129, and 135. In this case, this section of the manual must describe the procedures to ensure that maintenance is performed in accordance with the air carrier’s program and maintenance manual. These procedures must ensure that the air carrier has provided the repair station with the information necessary to ensure compliance with this requirement. The air carrier may provide the repair station with the applicable sections of its maintenance program or manuals at the time the work is performed. On the other hand, the purchase order or other contractual documents from the air carrier could clearly state the source of the data (manufacturer’s or air carrier’s manual) used to perform the requested maintenance along with any other requirements of its program or maintenance manual. If the repair station performs an inspection for a certificate holder conducting operations under part 125, the manual must contain procedures to ensure the inspections are performed in accordance with the operator’s approved inspection program. Again, the operator may provide the repair station with the applicable sections of its inspection program or clearly outline the requirements on the purchase order.
c. Identify Responsibilities. The procedures should identify who is responsible (by title) for keeping all of the operators’ data current, and where these manuals/sections will be located if retained at the repair station. The procedures also must explain what air carrier or commercial operator information must be available to maintenance personnel when the work is performed.
e. Line Maintenance Authorization. The FAA may authorize a certificated… › (1) The repair station performs the maintenance in accordance with the…
Additional procedures will be required to ensure that purchase orders are thoroughly reviewed. This review will be necessary to ensure that the air carrier has clearly specified what technical data to use for performing the maintenance. Employees may need additional training to properly perform this review. The traveler or work-order system of the repair station may be used to integrate this information into the quality control system. If the repair station transfers requirements from the air carrier or commercial operator to its maintenance personnel by special instructions on the work order or traveler, that section of the quality control system must clearly explain how this is accomplished.
d. Organization. The repair station performing maintenance for an air carrier must have an organization adequate to perform the work. This includes the ability to distinguish the work performed for different operators. Additionally, if the repair station is performing RII inspections the organizational structure must provide separation of maintenance and inspection personnel. The air carrier, not the repair station, determines the maintenance actions that are RII. If the repair station’s inspectors are authorized to perform RII for the air carrier, the air carrier must ensure that the inspectors are trained on the carrier’s RII procedures, including how the inspection is performed and recorded.
(1) The inspectors performing RII for the carrier must be qualified and authorized by the carrier. This authorization is usually in written format, often a card carried by the inspector. The authorization may need to be renewed, depending on the air carrier’s procedures. The procedures in the RSM should include who will maintain a list of current RII inspectors, how an inspector is added to the list, and where the list is located.
(2) The repair station should request information from the air carrier or commercial operator pertaining to at least the following issues:
(a) RII.
(b) Training requirements for the work being performed on the operator’s behalf, including who will provide the training.
(c) Maintenance duty time requirements.
(d) Special maintenance or alteration instructions per engineering orders, build lists, and other methods, techniques, and practices in the operator’s manual per part 43, § 43.13(c).
(e) Recordkeeping requirements, including who is responsible for maintaining the files.
e. Line Maintenance Authorization. The FAA may authorize a certificated repair station to perform line maintenance for an air carrier conducting operations under parts 121, 129, and 135, provided that:
(1) The repair station performs the maintenance in accordance with the operator’s manual, if applicable, and approved maintenance program.
h. Initiate Development. Addressing the following concerns (if… › (7) How does the repair station ensure that personnel comply with its…
(2) The repair station has the necessary equipment, trained personnel, and technical data to perform the line maintenance.
(3) The repair station’s OpSpecs include an authorization to perform line maintenance.
f. Line Maintenance Requirements. If the repair station is going to perform line maintenance, its manual must include procedures to ensure that the necessary equipment, technical data, and trained personnel are available before the maintenance can be performed. This should include who, by title, will be responsible for ensuring that the necessary equipment, technical data, and trained personnel will be available when the work is being performed.
g. Coordination with the Air Carrier. The repair station’s training program can be conducted in coordination with the air carrier. The specific training an employee receives should be recorded in the employee’s training record. The procedure will need to include who, by title, is responsible to ensure that training is conducted and recorded. The repair station should maintain a list of individuals who are trained by the air carrier to perform line maintenance. Although air carrier maintenance requirements may be incorporated into the repair station’s training program, the repair station must follow its training program requirements with respect to conducting the training, recording the training in employee training records, and qualifying those individuals authorized to perform line maintenance for an air carrier. Air carrier training does not relieve the repair station from the requirement to ensure its personnel are trained for the maintenance it is rated to perform.
h. Initiate Development. Addressing the following concerns (if applicable) will initiate development of the procedures for performing maintenance for an air carrier:
(1) Who is responsible (by title) for keeping a file of the air carrier’s procedures, including the necessary technical data?
(2) Who is responsible (by title) for review and amendment of purchase orders for complete and correct instructions? Is that person trained?
(3) Who will maintain the list of current RII inspectors?
(4) Does the RSM include procedures to ensure that the necessary equipment, trained personnel, and technical data will be available for line maintenance?
(5) Who is responsible for coordinating the training program with the air carrier?
(6) Does the repair station roster include authorization for individuals performing line maintenance and RII?
(7) How does the repair station ensure that personnel comply with its manual and appropriate sections of the air carrier’s manual—regardless of location?
NOTE: The authorization to perform line station maintenance for an air carrier is not a rating. A certificated repair station must have established housing and facilities. However, only the requirement to provide suitable
AC 145-9 CHG 1 3/19/09
housing to enclose the largest type and model aircraft for airframe-rated repair stations has been waived by § 145.205(d). The FAA understands that housing and facilities at airports is extremely difficult to obtain and expensive to maintain.
b. Contract Maintenance. The regulations allow a repair station to… › (6) Provide a procedure that confirms by inspection or test that the…
4-7. CONTRACT MAINTENANCE INFORMATION.
a. References:
• Section 145.211(c), and
b. Contract Maintenance. The regulations allow a repair station to contract any maintenance, preventive maintenance or alteration for which it holds a rating. A certificated repair station may not provide only approval for return to service of a complete type certificated product following contract maintenance, preventive maintenance, or alterations. The contract work can be performed by FAA-certificated or noncertificated entities when the repair station takes responsibility for the work scope performed by issuing an approval for return to service. In order to exercise the contracting privilege, the repair station must:
(1) Make a list of maintenance functions that it:
(a) Is certificated to perform but requests approval to contract out; and,
(b) Takes regulatory responsibility for issuing an approval for return to service for the exact same work under its rating.
(2) Obtain approval of the listed functions in accordance with § 145.217 and provide the list to the FAA in accordance with the procedures in § 145.209.
(3) Ensure that it qualifies the entities to which it contracts those maintenance functions in accordance with § 145.201(a)(2) (quality system).
(4) Maintain a current list of those contractors in accordance with § 145.217 and provide the list to the FAA in accordance with § 145.209.
(5) Ensure that it has procedures to perform the incoming inspection, final inspection and return to service of articles in accordance with the pertinent subparagraphs of § 145.211(c)(1).
(6) Provide a procedure that confirms by inspection or test that the work was performed satisfactorily (which may be able to be determine by review of the paperwork setting forth the exact steps performed and the inspections and tests performed) in accordance with § 145.217.
d. Material and Equipment. A repair station must have the material and… › (2) The repair station may also wish to provide a list of those…
3/19/09 AC 145-9 CHG 1
NOTE: Purchase of maintained parts from another repair station (including exchanges), brokerage and using another certificated repair station to perform work that is outside the original repair station’s ratings are not maintenance functions requiring FAA approval. These are instances where the purchasing repair station is not exercising the privileges of its certificate. When a repair station requests work or sells a previously maintained article (including type certificate products) it is acting solely as a distributor. Although the purchasing repair station may induct the part through its receiving inspection process, it is merely relying on the work previously performed at another certificated entity and is not exercising the privileges under 145.201(a)(2).
c. Contract Maintenance Information Required by § 145.217. The RSM must contain procedures for maintaining and revising the contract maintenance information required by § 145.217. This information is required for contracting to both FAA-certificated and noncertificated facilities. The information required includes the approved maintenance function to be contracted, the name of each outside facility to which the repair station contracts such maintenance and the type of certificate and ratings held, if any. The QCM/section should describe the system and procedures used for qualifying both FAA-certificated and noncertificated entities and surveilling noncertificated entities who perform maintenance, preventive maintenance, or alterations for the repair station. These procedures may be contained in one manual or in separate documents that are part of the manual system.
d. Material and Equipment. A repair station must have the material and equipment necessary to perform the functions appropriate to its rating. However, it need not have the tools and equipment for functions it is authorized to contract out pursuant to its FAA approved list of maintenance functions. When exercising the privileges of its certificate, a repair station may contract maintenance functions to FAA-certificated facilities and non-FAA-certificated entities only if the maintenance functions are approved by the FAA The repair station must request approval before it can contract a maintenance function. If the FAA approves the contracted maintenance function, the repair station will determine who performs the maintenance.
(1) The types of maintenance functions that the repair station may wish to have approved fall into two categories. First, the types of maintenance functions that must be contracted because the repair station does not have the housing, facilities, materials, or equipment available on its premises and under its control. These may include plating, heat treatment, special Nondestructive Testing (NDT) or inspection, or the maintenance or alteration of components or sub-assemblies. This list should be categorized broadly, such as specialized services or components of articles for which the repair station has the overall rating.
(2) The repair station may also wish to provide a list of those maintenance functions for which it has the housing, facilities, equipment, and materials “in-house,” but may need to contract to another facility because of workload or emergency situations. For example, an airframe rated repair station may have the capability to perform maintenance or alteration on landing gear, but if the in-house facility cannot accomplish the work scope within a specified time, it may want to contract that work to another facility. It would not be able to contract the
4-7. CONTRACT MAINTENANCE INFORMATION. › a.
AC 145-9 CHG 1 3/19/09
work unless the maintenance function of landing gear maintenance was on its FAA-approved list.
(3) Additionally, the repair station may wish to provide a method for which a maintenance function can be added to its FAA approved function list on an emergency basis. This would be accomplished by explaining how the maintenance function would be added and how the FAA approval would be obtained in a short period of time. The repair station should coordinate closely with its principal inspector and its local CHDO regarding these emergency procedures.
e. Establish Procedures. Before contracting out a function, the repair station should establish:
(1) Procedures to obtain approval for the maintenance function.
(2) Procedures to qualify the contractor.
(3) Procedures to surveil the contractor if the contractor does not perform approval for return to service.
(4) A list of contractors and procedures to properly maintain that list.
(5) Technical training on contracted functions for receiving inspection personnel.
(6) Procedures for receiving inspections that provide enough technical detail to determine acceptability of an article.
(7) Procedures for complying with the test and/or inspection requirement of § 145.217(b)(3) when contracting to a noncertificated person.
f. Contracting to FAA-Certificated Facilities. A certificated repair station may not provide only approval for return to service of a complete type-certificated product following contract maintenance, preventive maintenance or alterations. If the repair station chooses to exercise the privileges of its certificate by issuing an approval for return to service for a maintenance function contracted to an FAA-certificated repair station, the repair station must determine that the contracted repair station is properly rated to perform the maintenance. A repair station may issue an additional approval for return to service under its privileges, such as tagging a previously maintained or altered article as inspected, provided the repair station:
(1) Has the appropriate rating for the article,
(2) Is approved to contract out the maintenance function, and
(3) Conducts the maintenance, preventive maintenance or alteration, including inspection in accordance with § 43.13 and part 145.
3/19/09 AC 145-9 CHG 1
g. Contracting Maintenance Functions to Noncertificated Persons.
4-7. CONTRACT MAINTENANCE INFORMATION. › k. FAA Inspections. Maintenance contracts with noncertificated persons…
(1) If the repair station contracts to noncertificated persons, the repair station must ensure that:
(a) The noncertificated person follows a quality control program equivalent to the FAA-certificated repair station’s system with respect to the work being performed for the certificated repair station;
(b) The repair station remains directly in charge of the work performed;
(c) The repair station verifies by inspection or test that the work was performed satisfactorily; and
(d) The article is airworthy with respect to the work performed by the noncertificated person.
(2) The repair station must verify by test or inspection that the work has been performed satisfactorily and that the article is airworthy before approving it for return to service.
h. Procedures. Procedures in the RSM should include the title of the person responsible for the contract maintenance program. The procedures must also include provisions for maintaining the contracting information in a format acceptable to the FAA. The information is not required to be in the manual, but if included, it must identify:
(1) The name of each outside contracted source,
(2) The maintenance function(s) contracted to each source, and
(3) The type of certificate and ratings, if any, held by each source.
i. Initial Qualification. The procedures in the RSM must describe how the noncertificated person is initially qualified. It also should describe how the repair station ensures that the noncertificated person continues to follow the quality control program equal to the repair station’s for the work being performed on the repair station’s behalf.
j. Coordinating Communications. Procedures for coordinating communications between the repair station and the contracted source should be established. If the repair station performs any maintenance for an air carrier, the procedures should explain any special requirements (such as performing the work in accordance with the air carrier’s program). Procedures should describe how the repair station would address any problems with quality or delivery. Any recurring problems should be addressed in the corrective action program.
k. FAA Inspections. Maintenance contracts with noncertificated persons must include provisions that allow the FAA to make an inspection and observe the noncertificated person’s work on that article. The RSM should include procedures to ensure that contracts contain the provision for FAA inspections. The individual in charge of the contract maintenance program or a delegated assistant/auditor may be required to accompany the FAA during these inspections.
(14) How is the receiving inspection performed on articles returned… › (b) Do the receiving inspectors have the appropriate technical data to…
These inspections will determine if the repair station is able to continue to contract the maintenance function(s) to a noncertificated person.
l. Initiating Procedures. The following questions or concerns are offered as a guide and are intended to help initiate the procedures in the RSM(s). They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the repair station’s needs.
(1) Who, by title, is responsible for the contract maintenance program?
(2) What is the title of the person responsible for maintaining the list of contract maintenance functions?
(3) What is the title of the person responsible for maintaining the list of facilities to which maintenance functions are contracted?
(4) What is the title of the person responsible for forwarding revisions of the lists to the CHDO?
(5) How will the CHDO approve additions to the list of maintenance functions?
(6) When will the CHDO be notified of revisions to the list?
(7) How will the CHDO be notified?
(8) If the list is maintained on electronic media, does the CHDO have compatible hardware and software to review/refer to the contract maintenance list and procedures?
(9) Who will maintain current copies of the Air Agency Certificates and OpSpecs for the FAA-certificated contract sources (initial as well as revisions)?
(10) Do the contract provisions for noncertificated persons include provisions for FAA inspection?
(11) How will certificated and noncertificated maintenance contract sources be qualified?
(12) How often will the repair station surveil the contracted noncertificated persons?
(13) Are the auditors that inspect contract maintenance sources trained?
(14) How is the receiving inspection performed on articles returned after maintenance from certificated and noncertificated sources?
(a) Are the receiving inspectors properly trained?
(b) Do the receiving inspectors have the appropriate technical data to determine airworthiness?
4-8. PROFICIENCY OF INSPECTION PERSONNEL. › d. Training. The procedures should also describe how inspectors become…
(c) What criteria are used to determine if the contracted source is meeting all requirements?
(d) Are discrepancies with contracted sources included in the repair station’s corrective action program?
4-8. PROFICIENCY OF INSPECTION PERSONNEL.
a. References:
• Section 145.157, and
b. Requirements of Inspection Personnel.
(1) This section of the manual must include procedures for establishing and maintaining proficiency of inspection personnel. Section 145.155 requires the repair station to ensure that inspection personnel are thoroughly familiar with the following:
(a) Applicable regulations.
(b) Inspection methods, techniques, practices, aids, equipment, and tools used to determine the airworthiness of the article.
(2) Inspection personnel must also be proficient in using the various types of inspection equipment and visual inspection aids appropriate for the article being inspected. Inspectors must be listed on a roster and also understand, read, and write English.
c. Establish the Qualifications of the Inspection Personnel. Procedures in this section of the manual should address how the repair station will establish the qualifications of the inspection personnel. This initial qualification may be based on testing or previous experience or training. If the inspector has previous experience, the employment records should describe the type of inspections and maintenance work performed, methods and techniques used, and total years of experience as an inspector, as required by § 145.161. The procedure should establish the minimum amount of experience required before an inspector can be listed on the roster, and who by job title will make that determination.
d. Training. The procedures should also describe how inspectors become qualified through on-the-job training (OJT) and/or formal classroom training. This training may be described in this section of the manual or in the section describing the training program for all repair station personnel. Training should include initial qualification as well as recurrent training or testing to maintain proficiency. Inspection personnel may also require additional special training in new techniques. This may be necessary after additional components are added to the
g. Initiate Procedures in the QCM. The following questions or concerns… › (9) Are the persons performing RII inspections and approvals for return…
ratings or capabilities of the repair station or when new inspection aids or techniques are applied. Inspectors performing NDT may need to meet the qualification requirements of other industry standards, such as eye exams.
e. Specifications and Current Data. Inspection personnel need current technical data to properly perform their tasks. They need to understand current specifications involving inspection tolerances, limitations, procedures established by the manufacturer, SBs, and ADs. Inspection personnel also need to be familiar with the RSM and QCM for the repair station, as well as the applicable Federal aviation regulations. Procedures in the manual should address where the technical data is located, who is responsible for maintaining the current data, and how the inspectors will be made aware of changes.
f. Authority to Approve an Article for Return to Service. If the person performing the final inspection is also authorized to approve an article for return to service, that person must be certificated under part 65 for repair stations located within the United States. If the repair station is located outside the United States, the person authorized to perform a final inspection and approve an article for return to service must meet the requirements of § 145.157. If final inspection personnel are authorized to approve an article for return to service, procedures in the manual will need to address how they are authorized and qualified.
g. Initiate Procedures in the QCM. The following questions or concerns are offered as a guide and are intended to help initiate the procedures in the QCM. They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the needs of the repair station.
(1) How does the repair station establish minimum qualifications for inspection personnel? What is the title of the person making this determination?
(2) How will the inspector maintain proficiency? What methods are used?
(3) Do the records of training indicate the method, length, instructor, and dates? Are they current?
(4) Do the employment records of the inspectors describe any previous experience?
(5) Is the necessary current technical data available and accessible for the inspectors?
(6) What is the title of the person responsible for ensuring that inspectors maintain proficiency?
(7) Are the inspectors listed on the roster?
(8) Do the inspectors read, write, and understand English?
(9) Are the persons performing RII inspections and approvals for return to service certificated under part 65 (if in the United States)?
4-9. CURRENT TECHNICAL DATA. › e. Document Control Procedures. In some repair stations, the technical…
(10) Will the inspectors require any special training, such as NDT? Who will be responsible for the training? How will the repair station ensure that NDT personnel continue to meet any required industry standards?
4-9. CURRENT TECHNICAL DATA.
a. References:
• Section 145.201(c), and
b. Currency of Technical Data. This section of the manual must contain the procedures for ensuring that current technical data is available for the scope of work the repair station is performing. Section 43.13(a) requires each person performing maintenance, alteration, or preventive maintenance to use the methods, techniques, and practices prescribed in the current manufacturer’s maintenance manual, Instructions for Continued Airworthiness (ICA), or other methods, techniques, or practices acceptable to the Administrator. Section 145.201(c) states that a certificated repair station may not approve for return to service any article unless the maintenance, preventive maintenance, or alteration was performed in accordance with the applicable approved technical data or data acceptable to the FAA.
c. Data Used. The technical data used by repair stations could include any of the following:
(1) FAA technical data (such as ADs, Type Certificate Data Sheets, etc.).
(2) Manufacturer’s technical data (such as maintenance manuals and SBs).
(3) Engineering data (such as DER-approved data or data developed by the repair station and approved by the FAA).
d. Availability. The data used by the repair station to perform a specific maintenance function must be current and available to maintenance and inspection personnel when the maintenance is being performed. The procedures should ensure that someone in the facility is responsible for maintaining the technical data in a current condition. Status of the manuals may be confirmed by making periodic phone calls to the manufacturer, etc. The procedures should ensure that any subscriptions to required technical data are renewed as necessary. The procedure should describe how the revised technical data will be inserted into existing documents and how the appropriate individuals in the repair station will be notified about revisions.
e. Document Control Procedures. In some repair stations, the technical data is issued in the form of controlled documents. Procedures for these facilities will need a complete description of the document control system, including distribution, accountability, and availability. Document control procedures may include:
j. Guide. The following questions or concerns are offered as a guide… › (1) What is the title of the person responsible for revising and…
(1) Approval of the documents before distribution.
(2) Identification of changes.
(3) Provisions to ensure that relevant versions of applicable documents are available at points of use.
(4) Provisions to ensure that documents of external origin are identified and controlled.
(5) Procedures to prevent the use of obsolete documents.
f. Master Library. Larger repair stations may include provisions for distributing data from a master library to individuals or shop libraries throughout the facility. The procedure must ensure accurate and timely distribution of the material. Additional procedures will need to address who revises the shop library documents, how the documents are revised, and how the information is distributed.
g. Manufacturer’s Drawings and Data. Repair stations that are associated with or part of a production approval holder facility often use the manufacturer’s drawings and data to perform maintenance. This data may not meet the requirements of § 43.13(a). These facilities should also be cautioned that the parts manufactured by the production side of the facility cannot be used by the repair station unless the parts are FAA-approved through a Parts Manufacturer Approval (PMA), Technical Standard Order (TSO), Type Certification (TC), or other means.
h. National Language. Technical data used by repair stations located outside the United States may be translated into the national language. If the data requires translation before distribution, the procedures must ensure an accurate, timely, and complete translation. Provisions should be made for quality control personnel to review and approve the translated material before distribution. The technical data that needs to be translated may include graphs, diagrams, or other visual aids. The repair station must retain in English any data that demonstrates compliance with the requirements of part 43.
i. Software Revisions. Those facilities that use computer software for component testing (of airborne systems or equipment, avionics systems, engines, etc.) will need to include procedures describing how revisions/updates are made and how the current software is distributed. The procedures will need to address system security to prevent inadvertent changes to the software and methods to ensure that only the current revision/version of the software is used. Distribution and revision of software is often handled by a group other than those responsible for revision and distribution of paper documents.
j. Guide. The following questions or concerns are offered as a guide and are intended to help initiate the procedures in the manual. They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the needs of the repair station.
(1) What is the title of the person responsible for revising and maintaining the technical data?
4-10. INSPECTION AND QUALITY CONTROL SYSTEM. › d. General. Describe the inspection system in detail, from establishing…
(2) How does the repair station ensure that the data is current?
(3) How is the technical data distributed throughout the company?
(4) How does the repair station ensure that current technical data is available to the staff?
(5) What is the title of the person responsible for control and distribution of the documents from a master library to the shop/office libraries located in the facility?
(6) If the technical data requires translation, who is responsible for performing the translation and quality checks? How will the data be revised and distributed?
(7) If the repair station uses computer software for component testing, who is responsible for maintaining the software, and how are revisions made and distributed?
4-10. INSPECTION AND QUALITY CONTROL SYSTEM.
a. References:
• Section 145.211, and
b. System and Procedures. This section of the manual must include a description of the system and the procedures used for:
(1) Inspecting incoming raw materials to ensure acceptable quality.
(2) Performing preliminary inspections of all articles that are maintained.
(3) Inspecting all articles involved in an accident for hidden damage.
(4) Performing the final inspection and approval for return to service of maintained articles.
c. Guide to Initiate Inspection Procedures. The concerns or questions in the following paragraphs are offered as a guide and are intended to help initiate the inspection procedures in the QCM/section. They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the needs of the repair station.
d. General. Describe the inspection system in detail, from establishing the purchase of aviation articles and how that material is inspected upon receipt, receiving customer’s articles, progressing through each inspection step, and ending in final inspection and approval for return to service. Describe each step in a format easily understood by the employees. A flowchart may be helpful in developing these procedures. This section should also describe the system for controlling and documenting the work in process (work order system).
g. Receiving Policy. This section of the manual should address the… › (4) If the Repair station is dual certificated under another authority…
e. Reporting Malfunctions or Defects. Section 145.221 requires the repair station to notify the FAA within 96 hours after discovering any failure, malfunction, or defect of an article. Many repair stations use FAA Form 8010-4, Malfunction or Defect Report, to comply with this requirement. Information for completion of this form maybe found in AC 20-109, current edition. Examples of the types of information received on these reports may be found in AC 43-16, Aviation Maintenance Alerts, current edition. The regulation also states that the repair station may submit a Service Difficulty Report—Aeronautical Equipment, FAA Form 8070-1, for a certificate holder operating under 14 CFR parts 121, 125, or 135. Information on completing Form 8070-1 is attached to the form. The repair station should not report the same failure, malfunction, or defect using more than one report. The manual should contain procedures describing how the report will be completed and forwarded to the FAA. A copy of the form and instructions for its completion should be included in the forms section of the manual.
f. Continuity of Inspection Responsibility. Include procedures for ensuring that the responsibilities of its inspectors are properly performed if they cannot complete the task. If the facility uses multiple shifts, include procedures to ensure a continuing responsibility for maintenance in progress with status books, shift change logs, or similar documents.
g. Receiving Policy. This section of the manual should address the procedures used for accepting consumable materials and customer parts. Procedures included within this section will depend on the size, complexity, and ratings of the facility. The manual should describe generally how material is ordered, stocked, and requisitioned for maintenance or alteration purposes. A general description of how the stock room operates with respect to handling and storage should be included in this section. Additionally, this section may include the method for handling, storing, and using shelf life items and materials.
Continue reading ↓ 120 of 197 passages shown