Radar Vectors
Advisory Circular Current Issued Oct 6, 2017 AFS-300 87 pages Copy saved Nov 18, 2026

AC 145-9A Guide for Developing and Evaluating Repair Station and Quality Control Manuals

This advisory circular (AC) provides informational material for all repair station certificate holders and/or applicants under Title 14 of the Code of Federal Regulations (14 CFR) part 145 to develop and evaluate a Repair Station Manual (RSM) and Quality Control Manual (QCM). This AC describes an acceptable, but not the only means, to develop a manual and comply with the referenced regulations.

Official source ↗ Open PDF

U.S. Department of Transportation Federal Aviation Administration

Advisory Circular

Subject: Guide for Developing and

Evaluating Repair Station and Quality Control Manuals

Date: 10/6/17 AC No: 145-9A Initiated by: AFS-300 Change:

This advisory circular (AC) provides informational material for all repair station certificate holders and/or applicants under Title 14 of the Code of Federal Regulations (14 CFR) part 145 to develop and evaluate a Repair Station Manual (RSM) and Quality Control Manual (QCM). This AC describes an acceptable, but not the only means, to develop a manual and comply with the referenced regulations.

John S. Duncan Executive Director, Flight Standards Service

Paragraph Page › 5.8 Proficiency of Inspection Personnel … 5-23

ii

CONTENTS Paragraph Page

Chapter 1. General Information … 1-1

1.1 Purpose … 1-1

1.2 Cancellation … 1-1

1.3 Related 14 CFR Parts … 1-1

1.4 Definition of Terms … 1-1

1.5 Background … 1-4

1.6 Where You Can Find This AC … 1-4

1.7 AC Feedback Form … 1-4

Chapter 2. Manual Contents and Format … 2-1

2.1 The Manual(s) … 2-1

2.2 Combining Portions of the RSM with the QCM … 2-4

2.3 Identification and Control of Sections … 2-5

2.4 Sample Procedure Formats … 2-6

Chapter 3. Manual Revision and Control … 3-1

3.1 Procedures for Revision … 3-1

3.2 Provisions of Control … 3-2

3.3 Electronic Format … 3-2

Chapter 4. Repair Station Organizational Chart … 4-1

4.1 Organizational Chart … 4-1

4.2 Duties and Responsibilities … 4-2

Chapter 5. Repair Station and Quality Control Manual Elements … 5-1

5.1 Repair Station Personnel Roster … 5-1

5.2 Operations, Housing, Facilities, Equipment, and Materials … 5-3

5.3 Capability List (CL) … 5-6

5.4 Training Program Revision … 5-8

5.5 Work Performed at Another Location … 5-9

5.6 Maintenance, Preventive Maintenance, and Alterations Performed for Air Carriers Under 14 CFR Parts 121, 125, 129, and 135 … 5-14

5.7 Contract Maintenance Information … 5-18

5.8 Proficiency of Inspection Personnel … 5-23

iii

5.9 Current Technical Data … 5-25

5.10 Inspection and QC System … 5-28

List of Figures › Figure 5-3. Roster Format Example 3 … 5-3

5.11 Required Records and Recordkeeping … 5-38

5.12 Calibration of Measuring and Test Equipment … 5-41

5.13 Taking Corrective Action on Deficiencies … 5-45

Appendix A. Forms … A-1

Appendix B. Checklist … B-1

List of Figures

Figure 2-1. Example Structure of a Single Manual System … 2-5

Figure 2-2. Sample Procedure Format 1 … 2-7

Figure 2-3. Sample Procedure Format 2 … 2-8

Figure 2-4. Sample Procedure Format 3 … 2-9

Figure 2-5. Sample Procedure Format 4 … 2-11

Figure 4-1. Example Repair Station Organizational Charts … 4-1

Figure 4-2. Narrative Format Sample … 4-2

Figure 4-3. Outline/List Format Sample … 4-3

Figure 4-4. ISO/Industry Format Sample … 4-3

Figure 5-1. Roster Format Example 1 … 5-2

Figure 5-2. Roster Format Example 2 … 5-3

Figure 5-3. Roster Format Example 3 … 5-3

1.4.5 Capability List (CL).

CHAPTER 1. GENERAL INFORMATION

1.1 Purpose. This document is a guide for developing and evaluating the Repair Station Manual (RSM) and Quality Control Manual (QCM) required by Title 14 of the Code of Federal Regulations (14 CFR) part 145, §§ 145.207 through 145.211. This guide does not provide a complete sample RSM and QCM for all repair stations. The examples included illustrate one of many possible ways to comply with the regulations.

1.2 Cancellation. This advisory circular (AC) cancels AC 145-9 CHG 1, Guide for Developing and Evaluating Repair Station and Quality Control Manuals, dated March 19, 2009.

1.3 Related 14 CFR Parts. Parts 1, 21, 33, 39, 43, 65, 91, 121, 125, 129, 135, and 145.

1.4 Definition of Terms.

1.4.1 Acceptable. Data that meets the requirements of the applicable regulations.

1.4.2 Accountable Manager. The person designated by the certificated repair station (CRS) who is responsible for and has the authority over all repair station operations that are conducted under part 145, including ensuring that repair station personnel follow the regulations and serving as the primary contact with the Federal Aviation Administration (FAA).

Note: The FAA’s definition of an accountable manager may differ from the European Aviation Safety Agency’s (EASA) definition of an accountable manager; however, one person may serve both positions.

1.4.3 Approved. Approved, unless used with reference to another person, means approved by the FAA or any person to whom the FAA has delegated its authority in the matter concerned; or approved under the provisions of a bilateral agreement between the United States and a foreign jurisdiction.

Note: For the FAA aviation safety inspector (ASI), “approved” or “approved by” means the item has been formally approved by the FAA (or appropriate Civil Aviation Authority (CAA)). Approvals are granted by letter, by a stamp of approval, by the issuance of operations specifications (OpSpecs), or by other official means.

1.4.4 Article. An aircraft, airframe, aircraft engine, propeller, appliance, or component part.

1.4.5 Capability List (CL). A CL is a list of articles by make and model or other nomenclature in which the repair station is rated to perform maintenance, preventive maintenance, or alterations.

2. Is not done according to accepted practices or cannot be done by… › 2. Is not done according to accepted practices or cannot be done by…

1.4.6 Contract Maintenance. Entering into an agreement between the originating CRS and another person or entity (FAA certificated or noncertificated) to perform maintenance functions on an article. The originating repair station will exercise the privileges of its certificate and assume responsibility for the work performed by the contracted person or entity.

1.4.7 Correction. A correction is an action to eliminate an identified nonconformity as it relates to the articles or the maintenance processes.

1.4.8 Corrective Action. Corrective action is an action to eliminate the cause of an identified nonconformity or other undesirable condition to prevent its recurrence. An example of a corrective action could be accomplished as a proactive initiative, such as a technically conforming article could be removed because of an upcoming life limit.

1.4.9 Designated Engineering Representative (DER). A private person designated by the FAA Administrator to act as its representative for examining, inspecting, and testing aircraft and related data. A DER may recommend approval or approve data within the limitations of his or her Certificate of Authority (COA).

1.4.10 Directly in Charge. Having the responsibility for the work of a CRS that performs maintenance, preventive maintenance, alterations, or other functions affecting aircraft airworthiness. A person directly in charge does not need to physically observe and direct each worker constantly, but must be available for consultation on matters requiring instruction or decision from a higher authority.

1.4.11 Line Maintenance. Line maintenance is any unscheduled maintenance resulting from unforeseen events, or scheduled checks that contain servicing and/or inspections that do not require specialized training, equipment, or facilities.

1.4.12 Maintenance. Inspection, overhaul, repair, preservation, and the replacement of parts, excluding preventive maintenance.

1.4.13 Maintenance Function. A step or series of steps in the process of performing maintenance, preventive maintenance, or alterations.

1.4.14 Major Alteration. An alteration not listed in the aircraft, aircraft engine, or propeller specifications that:

1. Might appreciably affect weight, balance, structural strength, performance, powerplant operation, flight characteristics, or other qualities affecting airworthiness; or

2. Is not done according to accepted practices or cannot be done by elementary operations.

1.4.25 Supervisor.

1.4.15 Major Repair. A repair that:

1. If improperly done, might appreciably affect weight, balance, structural strength, performance, powerplant operation, flight characteristics, or other qualities affecting airworthiness; or

2. Is not done according to accepted practices or cannot be done by elementary operations.

1.4.16 Mobile Field Service. Repair station personnel, materials, tools, and equipment deployed to perform work away from the fixed location for a special circumstance and/or for recurring work.

1.4.17 Mobile Maintenance Unit. A vehicle deployed by the repair station to transport materials, equipment, data, and personnel from one location to another.

1.4.18 Operations Specifications (OpSpecs). The official documents that describe the authorizations, ratings, and limitations of the repair station.

1.4.19 Preventive Maintenance. Simple or minor preservation operations and the replacement of small standard parts not involving complex assembly operations.

1.4.20 Procedure. A specified way to perform an activity or a series of steps, such as a procedure that describes the methods, steps, or means to carry out policy. A procedure should include who performs each task and when, where, and how the task is performed.

1.4.21 Quality Control Manual (QCM). A manual that describes the inspection and quality control (QC) procedures used by the repair station.

1.4.22 Rating. A part of the repair station’s certificate that describes the special conditions, privileges, or limitations issued under § 145.59 and/or § 145.61.

1.4.23 Repair Station Manual (RSM). A manual that describes the procedures and policies of a repair station’s operations.

1.4.24 Required Inspection Item (RII). The requirement to inspect an item of maintenance that, if not performed properly, or is done with improper parts or materials, could result in a failure, malfunction, or defect, endangering the safe operation of the aircraft. An RII must be inspected by a trained, qualified, and authorized inspector. The inspector must be listed on the repair station’s roster but cannot be the same individual who performed the work. (Refer to part 121, § 121.371; part 125, § 125.251; and part 135, § 135.429 for details of this requirement.)

1.4.25 Supervisor. Person or persons employed by the repair station that direct the work performed under the repair station certificate and OpSpecs. The supervisor must also oversee the work performed by any individuals who are unfamiliar with the methods, techniques, practices, aids, equipment, and tools used to perform the maintenance, preventive maintenance, or alterations.

1.7 AC Feedback Form.

1.4.26 Temporary/Temporarily. Transient; an arrangement without permanency, lasting for a limited time.

Note: The phrase “temporary transport” (especially as it relates to § 145.203(b) of the rule) is not defined or explained in the regulation or the preambles. An unspecified return-to-base frequency cannot be read into the current rule.

1.4.27 Traceability. The ability to verify the history, location, or application of an item by means of documented recorded identification.

1.4.28 Tracking. A method developed and utilized by the certificate holder to identify the location of work being performed away from the fixed location (by mobile field services, maintenance units, or other means).

1.5 Background. The FAA has revised this AC to incorporate policies and procedures identified in related FAA guidance for clarity and consistency. It also clarifies the minimum requirements for an RSM and QCM and provides guidance for items that should be included in these manuals. The RSM and QCM are essentially a “living” manual system. When regulations change or FAA guidance is revised, as well as when the repair station’s procedures and operations change, the manual(s) and procedures need to be reviewed, revised, and followed. Although repair stations range from very small (e.g., 1–2 person) operations to very large (e.g., 1,000+ person) repair stations, the suggested procedures within this AC should assist repair stations of all sizes in designing procedures that meet the intent of the regulations and its individual operations.

1.6 Where You Can Find This AC. You can find this AC on the FAA’s website at http://www.faa.gov/regulations_policies/advisory_circulars.

1.7 AC Feedback Form. For your convenience, the AC Feedback Form is the last page of this AC. Note any deficiencies found, clarifications needed, or suggested improvements regarding the contents of this AC on the Feedback Form.

CHAPTER 2. MANUAL CONTENTS AND FORMAT

2.1 The Manual(s).

2. Identification and Control of Sections of the Manual. › 2. Identification and Control of Sections of the Manual.

2.1.1 Combining Information. The applicant/certificate holder may combine portions required by § 145.209 with portions required by § 145.211 into one section or chapter of the manual system. For example, the procedures required in § 145.209 for RSM revision and the procedures required in § 145.211 for QCM revision could be combined into one chapter/section titled “Manual Revision.” The manual(s) content must include procedures required by the regulations, but may be formatted in any manner easily understood by employees of the repair station.

2.1.2 Accessibility. The repair station’s current RSM must be accessible for use by repair station personnel required by part 145 subpart D, as stated in § 145.207. Section 145.211 includes a QC system in which the CRS must prepare and keep current a QCM and requires repair station personnel to follow the QC system.

2.1.3 Checklist. Appendix B, Checklist, may be used to assist the applicant/certificate holder in reviewing the content of its manual(s). All items listed on the checklist may not be applicable to each repair station due to differences in ratings, sizes, and types of maintenance performed.

2.1.4 Submit the Manual. The applicant/certificate holder may submit the manual(s) to the responsible Flight Standards office on paper or electronically. If the repair station submits the manual as part of an initial certification, the manual may be submitted together with related documents, such as the application form and repairmen applications, to the responsible Flight Standards office. If the repair station submits the manual electronically, they should discuss the format, software, and revision procedures with the responsible Flight Standards office before submittal. The repair station must follow the procedures described in its manual when submitting revisions to an existing manual (see Chapter 3, Manual Revision and Control).

2.1.5 Required Content. The basic regulatory requirements for manual content are listed below and will be discussed in detail in the following sections of this AC.

2.1.5.1 RSM Elements.

1. Manual Revision and Notifying the Responsible Flight Standards Office. Procedures for revising the RSM and notifying the responsible Flight Standards office of revisions to the manual, including how often the office will be notified of the revisions (refer to § 145.209(j)).

2. Identification and Control of Sections of the Manual. A description of the system used to identify and control sections of the RSM (refer to § 145.209(k)).

• Performing the self-evaluation required by §§ 145.209(d)(2) and… › • Performing the self-evaluation required by §§ 145.209(d)(2) and…

3. Organizational Chart (§ 145.209(a)). An organizational chart identifying:

• Each management position with authority to act on behalf of the repair station.

• The areas of responsibility assigned to each management position.

• The duties, responsibilities, and authority of each management position.

4. Rosters. Procedures for maintaining and revising the rosters required by § 145.161 (refer to § 145.209(b)).

5. Housing and Facilities:

• A description of the housing (refer to § 145.209(c)). For example, this may include dimensions, construction method, heating, ventilation systems, environmental protection, lighting, door openings, and physical address.

• A description of the facilities, including the layout of the shop, hangar, work areas, segregation areas, material storage, or machining.

• A description of the equipment, tooling, and materials used to perform maintenance (refer to § 145.209(c)).

Note: The description of materials used to perform maintenance should not be a physical description of the material, but rather an explanation of the repair station’s handling and storage of the materials. If materials require specific environmental controls or cannot be stored next to certain chemicals or solvents, these should be identified. For example, it would not be acceptable to store oxygen equipment near petroleum products.

• If the repair station does not own the equipment, tools, and materials necessary to perform the maintenance, preventive maintenance, or alterations under its repair station certificate and OpSpecs in accordance with part 43, include procedures in the manual that describe how the repair station will obtain them (lease, rentals, etc.).

6. CL. Procedures for (if applicable):

• Revising the CL provided in §§ 145.209(d)(1) and 145.215.

• Responsible Flight Standards office notification of revisions to the list, including how often the repair station will notify the office of revisions (refer to § 145.209(d)(1)).

• Performing the self-evaluation required by §§ 145.209(d)(2) and 145.215(c), including methods and frequency of such evaluations and procedures for reporting the results to the appropriate manager for review and action.

7. Training Program. Procedures for revising the training program and submitting revisions to the responsible Flight Standards office for approval, in accordance with the procedures required by § 145.209(e).

3. Establishing and Maintaining Proficiency of Inspection Personnel. › 3. Establishing and Maintaining Proficiency of Inspection Personnel.

8. Procedures Governing Work Performed at Another Location (§ 145.209(f)):

• The work is necessary due to a special circumstance, as identified in § 145.203(a); or

• The work is performed on a recurring basis and the RSM includes procedures for accomplishing the work at a place other than the repair station’s fixed location, as identified in § 145.203(b).

9. Procedures for Maintenance, Preventive Maintenance, or Alterations Performed Under § 145.205 (if applicable). Procedures for performing maintenance, preventive maintenance, and alterations for certificate holders under parts 121, 125, and 135, and for foreign air carriers or foreign persons operating a U.S.-registered aircraft in common carriage under part 129 (refer to § 145.209(g)).

10. Contract Maintenance Procedures. Procedures for:

• Maintaining and revising the contract maintenance information required by § 145.217(a)(2)(i), including submitting revisions to the responsible Flight Standards office for approval (refer to § 145.209(h)(1)).

• Maintaining and revising the contract maintenance information required by § 145.217(a)(2)(ii) and notifying the responsible Flight Standards office of revisions to this information, including how often the office will be notified of revisions (refer to § 145.209(h)(2)).

11. Required Records and Recordkeeping System. A description of the required records and the recordkeeping system used to obtain, store, and retrieve the required records per §§ 145.209(i) and 145.219.

2.1.5.2 QCM Elements.

1. Revision Procedures and Notifying the Responsible Flight Standards Office. Refer to § 145.211(d).

2. Qualifying and Surveilling Noncertificated Persons Performing Maintenance, Preventive Maintenance, or Alteration for the Repair Station. Refer to § 145.211(c)(1)(vi).

3. Establishing and Maintaining Proficiency of Inspection Personnel. Refer to § 145.211(c)(1)(iv).

2.2.1 Possible Combination. › 2-1

4. Establishing and Maintaining Current Technical Data. Refer to § 145.211(c)(1)(v).

5. Inspection System. Description and procedures for (refer to § 145.211(c)(1)(i), (ii), (iii), and (vii)):

• Inspecting incoming raw materials.

• Performing preliminary inspection of all articles that are maintained.

• Inspecting all articles that have been involved in an accident for hidden damage before maintenance, preventive maintenance, or alteration is performed.

• Performing final inspection and return to service.

6. Calibration of Measuring and Test Equipment, Including Intervals of Calibration. Refer to § 145.211(c)(1)(viii).

7. Taking Corrective Action on Deficiencies. Refer to § 145.211(c)(1)(ix).

8. References. References, where applicable, to the manufacturer’s inspection standards for a particular article, including reference to any data specified by that manufacturer (refer to § 145.211(c)(2)).

9. Samples of Inspection Forms and Instructions for Completion. May be a separate manual (refer to § 145.211(c)(3)).

10. Portions Recommended for Manual Organization:

• Table of Contents.

• List of Effective Pages (LEP).

• Record of Revisions.

2.2 Combining Portions of the RSM with the QCM.

2.2.1 Possible Combination. Figure 2-1, Example Structure of a Single Manual System, illustrates one of several possible combinations that applicants/certificate holders could use to structure a single manual system. It includes the procedures required in both the RSM and the QCM. Other combinations may be possible depending upon the ratings, size, and complexity of the repair station. The manual’s content must include the applicable procedures required by the regulations, but may be formatted in any manner easily understood by employees of the repair station.

2.3.2 Related Subject Matter.

Figure 2-1. Example Structure of a Single Manual System

Repair Station Manual

Element + Quality Control Manual

Element =

Possible Chapter/Section

Title

Training program, revision, notifying responsible Flight Standards office

+

Establishing and maintaining proficiency of inspection personnel =

Training

Maintaining and revising contract information +

Qualifying and surveilling noncertificated persons =

Contract Maintenance

Manual revision, responsible Flight Standards office notification, identification, and control of sections

+

Manual revision and responsible Flight Standards office notification =

Manual Control

Records and recordkeeping system +

Establishing and maintaining current technical data =

Document Control

Etc. + Etc. = Etc.

2.2.2 Meeting Manual Requirements. The repair station should include a table referencing the manual contents listed in §§ 145.209 and 145.211 to clearly identify that the RSM and QCM meet regulatory requirements.

2.3 Identification and Control of Sections.

2.3.1 Page Numbering. Sequential numbering of the manual(s) from front to back may cause difficulty for the revision process. A minor revision to one of the first pages may cause a change in the content of each successive page. The FAA advises the repair station to divide the manual into several sections, so that a revision to one page of a section does not affect the entire manual.

2.3.2 Related Subject Matter. Most RSMs are divided into sections of similar subject matter. For instance, one section of the manual may contain all of the procedures related to the inspection system. The repair station may establish these sections, or the sections may be contained within an established industry format (such as the International Organization for Standardization (ISO)). The sample formats included in this chapter contain a few examples of the many possible methods used for identification. The sections may consist of several similar individual procedures grouped together through a common numbering system, or several similar procedures described in narrative format within a section. Regardless of the method used, each section must be identified and controlled.

2.4 Sample Procedure Formats. › 145

2.3.3 Table of Contents. Many RSM sections are controlled using a table of contents. The table of contents lists each section of the manual and the location in the manual. Some repair stations choose to reissue a complete section of the manual if any page within that section is revised. The table of contents for those facilities may indicate revision status for each section, rather than each page.

2.3.4 Master Document Control List. Some RSMs are controlled using a master document control list. This document lists each procedure and the revision status of that procedure. A unique number and revision status should identify each procedure within the manual system. If a page within a procedure is revised, the entire procedure is reissued. In this system, each procedure is identified and controlled, rather than each section.

2.3.5 Section Control. The procedures to control sections of the manual should address (as applicable):

• Identification;

• Revision status;

• Page numbering;

• Issue date; and

• Approvals of internal personnel responsible for the manual and revisions.

2.3.6 Additional Combinations. Additional combinations that work effectively within the facility and are acceptable to the FAA principal inspector (PI) may be included in the manual system.

2.4 Sample Procedure Formats. The following samples are provided to help the manual writer determine a possible format for the procedures in the manual system. These are only four examples of many possible formats. Part 145 sets the requirements for content, not format. The format used for the procedures in the manual should fit the size and complexity of the facility. If there are existing procedure manuals in the facility, the manual writer may wish to include the same format in the RSM(s). If facility employees are accustomed to a particular format, the manual writer should continue to use that format.

2.4.1.2 Disadvantages.

Figure 2-2. Sample Procedure Format 1

2.4.1 Format 1 Discussion.

2.4.1.1 Advantages. Figure 2-2, Sample Procedure Format 1, includes each of the six Safety Assurance System (SAS) safety attributes to assist in designing a procedure in a narrative format. This format is easy to write, as long as the author remembers to include all of the safety attributes. This format is usually easy for the reader to understand and requires no special training for the author or reader.

2.4.1.2 Disadvantages. The narrative can easily become too complex or wordy. The author may fail to include all of the safety attributes of the procedure. The narrative must be presented in a logical sequence so the reader can easily understand the flow of the procedure.

2.4.2 Format 2 Discussion. › 2-3

Figure 2-3. Sample Procedure Format 2

THE JOHN SMITH COMPANY OPERATING PROCEDURE 123

Title: Receiving Inspection Page 1 of 4

Revision: A Issue Date: November 12, 2001

---------------------------------------------------------------------------------------------------------

Reason: To ensure consistent quality of incoming raw material.

Scope: Applies to all raw material shipments received. This procedure does not apply to incoming parts received for repair.

Responsibility: The receiving inspector is responsible for inspecting all incoming raw materials.

Procedure:

1. The receiving inspector will visually inspect the container (if used) and/or material for any shipping or handling damage.

2. The receiving inspector will immediately report any shipping or handling damage to the purchasing department.

3. Compare the purchase order (copy located in receiving file) with the shipping document to ensure the material is correct.

4. Etc.

2.4.2 Format 2 Discussion. Figure 2-3, Sample Procedure Format 2, assigns responsibility as part of each procedure. The narrative should be written in a format easily understood by the person who uses and must follow the procedure. Note that the format also includes revision status, issue date, and page numbering. The reason and scope may be used to state the company policy or objective.

7.0 Records: › 7.4 Etc.

Figure 2-4. Sample Procedure Format 3

John Smith Overhaul & Repair

Quality Procedure—Control of Inspection, Measuring, and Test Equipment

QP 4.11

Approval Approval Revision/Date Reason for Change

John Smith, Sr. Jane Doe Original—04/01/2000 Original issue

John Smith, Sr. Jane Doe A—06/15/2000 Added gage request form

1.0 Purpose: To ensure that all precision tools and equipment are properly calibrated, identified, and maintained.

2.0 Scope: This procedure applies to all employees who use inspecting, measuring, and testing equipment, and those who calibrate that equipment.

3.0 Responsibility: The Director of Quality is responsible for ensuring that all inspecting, measuring, and testing equipment is calibrated and traceable. Only trained and qualified personnel are permitted to adjust and calibrate equipment.

4.0 Reference Documents:

4.1 QAP 15.0, Inspection and Test Status. 4.2 MIL-STD-120 Gage Inspection. 4.3 Work Instruction (WI) 4.11-1 through WI 4.11-20.

5.0 Definitions:

5.1 Accuracy of Measurement: The closeness of the agreement between the result of a measurement and the conventional true value of the measurement. 5.2 Uncertainty of Measurement: The result of the evaluation aimed at characterizing the range within the true value of a measurement. It’s estimated to lie generally within a given likelihood. 5.3 Etc. 5.4 Etc.

6.0 Procedure:

6.1 The gage calibration technician will maintain a computerized list of all precision tools and equipment using the Gage Control software program. 6.2 During the first week of the month, the gage technician should run the “Calibration Required” report, listing all tools and equipment that must be calibrated before the end of the month. 6.3 The gage calibration technician will issue a John Smith Recall Slip (Form 789) to the department or individual. This form states which tools are due for calibration and the date they must be returned to the tool crib. 6.4 Etc.

7.0 Records:

7.1 Form 789, Recall Slip. 7.2 Form 456, Record of Calibration. 7.3 Form 123, Identification Sticker. 7.4 Etc.

2.4.5 Format 4 Discussion.

2.4.3 Format 3 Discussion. Figure 2-4, Sample Procedure Format 3, is often used for procedures included in an ISO 9000 quality management system document. Note that space is provided to document approval and release of the document (part of a document control system). Terms used within the procedure are defined. Additional documents associated with this procedure are listed. The format is structured (perhaps too structured) for some organizations. The procedure follows a standard numbering system for each portion of the procedure, allowing for precise reference for paragraphs that may be discussed or revised. Work instructions and records may follow the same numbering convention (e.g., QP 4.12, WI 4.12-1, and Form 4.12-A). Forms may be included within the procedure or in a separate forms section of the manual system.

2.4.4 Introduction to Figure 2-5, Sample Procedure Format 4.

2.4.4.1 The following flowchart illustrates another possible method of presenting a procedure. Although the sample illustrates a simple procedure, complex processes could also be presented using a flowchart. The person using the manual would need to be familiar and comfortable with flowcharts and flowchart symbols.

2.4.4.2 The flowchart process may also be used to develop a procedure that was not previously documented. The procedure could be initially drawn on paper using a flowchart, and then described using the narrative format in the manual. This process works well when the users of the manual are more comfortable with narrative procedures rather than flowcharts.

2.4.4.3 Another possible use of the flowchart is to verify if a narrative procedure will work. This process is essentially the opposite of the process previously described. While reading the narrative of the procedure, a flowchart is created to visually represent the various steps. A review of the completed flowchart will show any redundant or missing steps.

2.4.4.4 A flowchart can also be used during a process audit. The auditor creates a flowchart while reviewing the performance of a particular process. The auditor then compares the process he or she observed with the process described in the manual. Any differences may be noted in the auditor’s report.

2.4.5 Format 4 Discussion. Format 4 requires the reader to have some familiarity with flowcharts, but can be easily understood by someone who understands the format. Because the flowcharts contain fewer words than other formats, the process can be read and understood quickly. This format takes longer to develop unless the author has specific software for that purpose.

Figure

Figure 2-5. Sample Procedure Format 4

CHAPTER 3. MANUAL REVISION AND CONTROL

3.1 Procedures for Revision.

3.1.1 References. Title 14 CFR part 145:

• Section 145.207(e).

• Section 145.209(j).

• Section 145.209(k).

• Section 145.211(c)(4).

• Section 145.211(d).

3.1.2 Requirements. The RSM and the QCM must contain procedures for revising the manual(s) and notifying the responsible Flight Standards office of revisions.

4. How will the repair station control revisions and submittals by… › 4. How will the repair station control revisions and submittals by…

Note: The regulations do not require FAA review and acceptance of revisions before implementation, provided the repair station follows the revision procedures in its manual. The repair station should have a procedure in its manual to recall revisions if the FAA finds a revision unacceptable.

3.1.3 Control Submissions and Revisions. This section of the manual must contain procedures to control the original submission of the manual and subsequent revisions. The procedures should ensure that persons issued a manual receive revisions. Repair station employees may require training on the content of the revisions, especially if a standard operating procedure (SOP) or inspection procedure is changed.

3.1.4 Control System Description. The manual must include a description of the system used to identify and control sections of the manual. The format and structure of this system is not specified by the regulation. This flexibility will accommodate the technological changes that permit repair stations to maintain and revise the manuals in different formats and manners.

3.1.5 Procedures. Regardless of the media used for the manual, the procedures for making revisions should include:

1. A person who is clearly identifiable (by title) has the responsibility for the quality of the process for making revisions.

2. A person who is clearly identifiable (by title) has the authority to set up and change a process and will submit revisions to the FAA for review and acceptance.

3. How will the repair station incorporate changes to revisions and document methods to accomplish a process?

4. How will the repair station control revisions and submittals by checks and restraints designed into the process to ensure the desired result?

1. Security. › 1. Security.

5. Are the process measures used to validate a process and identify problems or potential problems in order to correct them?

6. What interfaces and interactions between processes that must be managed in order to ensure desired outcomes are there?

7. How will the repair station ensure that the RSM is accessible for use by repair station personnel?

8. Identification of each revision to the text on each affected page. For example, a vertical bar in the margin or other suitable method may indicate the revised portion of text.

3.2 Provisions of Control. If the manual is in paper format, the revision and control part of the manual should contain the following (or equivalent) information:

3.2.1 Revisions. Procedures for revising the RSM and notifying the responsible Flight Standards office of revisions, including how the FAA will be notified of revisions.

3.2.2 Details. Provisions for selecting the revision number, the date of the revision, the pages revised, and a place for the person making the revisions to the assigned manual to sign or initial.

3.2.3 Manual Control Number and Assignment. Although the regulations do not state how manuals should be controlled, they do state that a manual control should be included in the procedures. The FAA suggests that each manual have a unique number assigned to it and the name of the individual, department, or group assigned to that particular manual. The manual procedure should identify who will maintain a master distribution list that contains the manual number, assigned individual, and revision status.

Note: An acknowledgement form is a common method of tracking the receipt and insertion of the revision by the manual holder, which ensures accountability. With this method, after receiving a revision, each manual holder inserts the revised pages into the manual, records incorporation of the revision in the record of revisions, and returns the signed acknowledgement form to the person responsible for manual control.

3.3 Electronic Format. The manual(s) may be maintained on a computer network or other electronic medium. AC 120-78, Electronic Signatures, Electronic Recordkeeping, and Electronic Manuals, provides additional guidance for electronic systems.

3.3.1 Network. If the manual is maintained on a network server, the following concerns should be addressed in the procedures:

1. Security. How will the repair station ensure that only authorized personnel make any changes? Who (by title) will be authorized to make those changes and how is that person authorized?

Note › Note

2. Access. Have the employees been trained to access the manual on the network? Is access protected by passwords? Do all of the supervisors and inspectors have access to the manual?

3. Revisions. How will the user know that the manual has been revised, and the content of that revision?

4. Availability. How will the repair station ensure that the current manual(s) are available for all shifts? How will the repair station ensure that manual users will have access to the manuals in the event of Internet or computer outages?

3.3.2 Disk. If the manual is maintained on a disk, the following concerns should be addressed in the procedures:

1. How will the manual and any subsequent revisions be distributed? How will receipt of the revision be documented?

2. Is the software used for writing the manual compatible with the software used by all manual holders, including the FAA?

3. Are all of the manual holders trained on the procedures necessary to access the manual at their workstations?

4. How can station personnel verify if the disks are current before they use them?

Note: Federal agencies can no longer refuse electronic versions of manuals, forms, record systems, etc. Federal law prohibits agencies from making the use of electronic media more difficult, or from requiring additional steps or procedures for users of electronic media.

CHAPTER 4. REPAIR STATION ORGANIZATIONAL CHART

4.1.3.2 Are the titles for the positions the same throughout the manual?

4.1 Organizational Chart.

4.1.1 Reference. Title 14 CFR part 145, § 145.209(a).

4.1.2 Authority. The organizational chart identifies (by title only) each management position with authority to act on behalf of the repair station. If the repair station performs work for air carriers or air operators under § 145.205 and is performing Required Inspection Items (RII), the FAA suggests that the chart reflect the separation between the maintenance and inspection departments.

Figure 4-1. Example Repair Station Organizational Charts

4.1.3 Procedure Details. Ensure that the following concerns are addressed in the manual procedures.

4.1.3.1 Are the titles and reporting structure for the organizational chart appropriate for the facility?

4.1.3.2 Are the titles for the positions the same throughout the manual?

Owner/President

4.1.3.3 Is each management position with authority to act on behalf of the repair station identified?

4.1.3.4 Is an accountable manager designated?

4.2 Duties and Responsibilities.

4.2.1 Organization. This section may be combined with the organizational chart as one section/chapter of a manual system. If the repair station documents its procedures in a format that includes a Responsibility section in each procedure, it will not need to have a separate Duties and Responsibilities section (see Chapter 2, Figure 2-3, Sample Procedure Format 2, and Figure 2-4, Sample Procedure Format 3).

4.2.2 Area of Responsibility. This section includes the area of responsibility assigned to each management position and the duties, responsibilities, and authority of each management position. Ensure that the duties and responsibilities are appropriate and that the positions exist within the company. Although not required by the regulation, many repair stations choose to include duties and responsibilities beyond the required management personnel. Positions described in the organizational chart should be included in the Duties and Responsibilities section to ensure consistency.

4.2.3 Additional Responsibilities. Duties and responsibilities that are outside the scope of the management, but are part of the regulatory requirements, should be described in this section of the manual (e.g., equipment maintenance, approval for return to service, applications for repairmen, and so forth).

Note 1: Only titles, not names, should appear in this section. Titles should be the same as on the organizational chart and elsewhere in the manual.

Note 2: Titles used in the following format samples are only examples.

Figure 4-2. Narrative Format Sample

Owner/President: The Owner/President is responsible for the overall operation of (name of the repair station) in accordance with the applicable Code of Federal Regulations (CFR). The Owner/President’s duties include maintaining an adequate and knowledgeable staff to plan, perform, supervise, and inspect the work being performed on civil aviation articles. The Owner/President may delegate all duties to the qualified persons as necessary. However, such delegation does not relieve the Owner/President of the overall responsibility.

(5) Does the manual have a procedure to determine if a supervisor or…

Figure 4-3. Outline/List Format Sample

Quality Manager: The Quality Manager reports to the President and is responsible for managing the repair station quality control (QC) system. The duties of the Quality Manager include:

(1) Supervising all inspection personnel.

(2) Maintaining a current file of pertinent technical data, including CFRs,

specifications, manufacturer’s maintenance manuals, Service Bulletins (SB), Airworthiness Directives (AD), and other data acceptable to or approved by the FAA.

(3) Ensuring the proper execution of FAA Form 337, Major Repair and Alteration

(Airframe, Powerplant, Propeller, or Appliance), when required.

(4) Etc.

Figure 4-4. ISO/Industry Format Sample

The duties and responsibilities may be addressed in the management responsibility section of the manual (i.e., section 4.1).

a. The following questions or concerns are offered as a guide and are intended to help the facility initiate the procedures in its RSM. They should not be considered all-inclusive. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and the needs of the repair station.

(1) Do the duties and responsibilities include the areas of responsibility assigned to each

management position?

(2) Do the duties and responsibilities indicate the reporting structure (to what other

position does each report)?

(3) Does the narrative describe the job function(s) that person performs (i.e., calibration,

training, personnel management)?

(4) Do the procedures ensure that the duties and responsibilities of supervisory and

inspection personnel are performed in their absence?

(5) Does the manual have a procedure to determine if a supervisor or inspector is

qualified for any delegated duties?

(3) Are persons with approval for return to service authority…

b. Consider the following when assigning duties and responsibilities within the repair station:

(1) Is each supervisor certificated?

(2) Do the inspectors understand, read, and write English?

(3) Are persons with approval for return to service authority certificated?

CHAPTER 5. REPAIR STATION AND QUALITY CONTROL MANUAL ELEMENTS

2. Where will the rosters be located? › 2. Where will the rosters be located?

5.1 Repair Station Personnel Roster.

5.1.1 References. Title 14 CFR part 145:

• Section 145.161.

• Section 145.209(b).

5.1.2 Records of Management, Supervisory, and Inspection Personnel. Personnel rosters are lists of management and supervisory personnel that include repair station officials who are responsible for its management and the names of its supervisors who oversee maintenance functions. These rosters can be maintained in paper or electronic format, but they must be made available to the FAA.

5.1.3 Roster Format. Each repair station may develop its own roster format, as long as it contains all of the appropriate names and employment summaries of each individual listed on the roster and required by § 145.161(a)(1) through (3).

5.1.4 Manual Inclusion. The rosters do not need to be included in the manual, but the procedures for maintaining and revising the rosters must be in the manual. If the rosters are not included in the manual, the procedure should describe how the roster will be made available to the FAA. The procedure should describe how the roster will be revised within 5 business-days when there is a change caused by termination, reassignment, change in duties or scope of assignment, or addition of any personnel.

5.1.5 Combination Roster. Although not required by regulation, it may be appropriate for the repair station to develop a combination roster, which would include initials, signatures, stamp numbers, certificate numbers, or any other information used to designate the authority of inspection or supervisory personnel who can sign/stamp off work documents or approve articles for return to service.

5.1.6 Employment Summaries. The repair station must maintain employment summaries for each person whose name appears on the rosters. Employment summaries are required by § 145.161(a)(4)(i) through (v), to include present title, total years of experience and the type of maintenance work performed, past relevant employment with names of employers and periods of employment, scope of present employment, and the type of mechanic or repairman certificate held and the ratings on that certificate, if applicable.

5.1.7 Roster Procedures. The following questions should be answered during the development of the procedures concerning the rosters:

1. Who is responsible (by title) for maintaining the rosters and employment summaries in current condition? Has an alternate been designated?

2. Where will the rosters be located? How will the rosters be made available to the FAA?

Figure

3. How will the rosters be revised within 5 business-days?

4. Is authority to approve an article for return to service shown on the rosters? Who is responsible for designating those individuals, and how are those individuals designated?

5. Are the managers, supervisors, inspectors, and persons authorized to approve articles for return to service all listed on the rosters?

6. Are the supervisors certificated, and with what type of certificate?

7. Are the persons authorized to approve articles for return to service certificated? (Each person authorized to approve articles for return to service must be certificated under 14 CFR part 65, unless located outside the United States.)

8. Are there employment summaries for each person on the roster?

5.1.8 Examples. The following are examples of possible roster formats.

Figure 5-1. Roster Format Example 1

5.2.3 Housing and Facilities.

Figure 5-2. Roster Format Example 2

Section: III Date Completed: 11/13/2001

Revision No. 1

Personnel

Title: Chief Inspector/Repairman

Authorized Signature: Kyle R. Bowman

FAA Airman Certificate Held: Repairman No. 123456789

Authorized to Sign: Logbooks and other approvals for return to service, Malfunction and Defect Reports

Figure 5-3. Roster Format Example 3

John Smith Component Repair, Inc.

Effective Date: 11/13/2001

Supervisory and Inspection Personnel Roster

TITLE NAME CERT. TYPE & NO. AUTHORITY

CEO John Smith N/A N/A

Q.C. Manager Jane Smith Repairman 1234567 FPI, Machining

Foreman Dan Jones Repairman 98765432 Machining, Cleaning

Chief Inspector David Jones N/A N/A

5.2 Operations, Housing, Facilities, Equipment, and Materials.

5.2.1 References:

• Title 14 CFR part 43.

• Sections 145.101 through 145.109.

5.2.2 Operations. This section of the manual should include a general description of the repair station operations. The manual should describe how the repair station operates, from receiving an article for maintenance to approval for return to service. The description could be in a narrative, flowchart, or other format. Any/all standard operating procedures (SOP) developed for the facility could be included to aid in describing the repair station’s normal, day-to-day business practices and/or operations.

5.2.3 Housing and Facilities. This section should include a description of the housing and facilities. This also could be in a narrative, flowchart, or other format, such as a drawing showing the floor plan of the facility. A drawing of the facility depicting the areas of

Note › Note

repair station operations is not regulatory, but can be helpful in describing the housing and facilities. If using a drawing to further describe the areas of operation within the repair station, the drawing could include the entrance(s), parking areas, and street locations. The drawing and description may include the type of heating, lighting, equipment location, shop areas, electrical, and compressed air outlets. A description of any facilities used for spray painting, avionics, engine or airframe repair, or any other work that would have special requirements should be included.

5.2.4 Equipment, Tools, and Materials.

5.2.4.1 The repair station must have the equipment, tools, and materials necessary to perform the maintenance in accordance with part 43. The equipment, tools, and materials must be located on the premises and under the repair station’s control when the work is being done, per § 145.109. Some of this equipment may be very expensive and the repair station may rarely use it. If the repair station does not own the equipment and it is not kept at the facility, the manual should describe how the equipment is obtained (e.g., lease, rental, etc.). The manual should also describe the procedure for ensuring the equipment is on the premises and under the repair station’s control at the time the work is being performed.

5.2.4.2 This section of the manual should also describe where the equipment is likely to be used and how the repair station will comply with special handling requirements for sensitive tools and equipment. Some test benches and special equipment may require calibration/verification after relocation. This section of the manual should describe how the repair station ensures that required calibration/verification is performed before using the equipment to perform maintenance or alteration on civil aviation articles. The RSM should identify which department is responsible for calibrating leased tools and equipment.

5.2.4.3 The RSM should include a description of the equipment used to perform maintenance. For example, if the facility includes a machining area, then a generic description of the types of machines located in that area should be included in the manual. The description should not be so specific that updating equipment would result in a manual revision. The equipment, tools, and materials must be those recommended by the manufacturer of the article or must be at least equivalent to those recommended by the manufacturer and acceptable to the FAA. The repair station may refer to a list of equipment maintained for other purposes, such as a list kept by the accounting department for tax purposes.

5.2.5 Equivalent Tools and Equipment.

Note: This section is not intended to discuss industry standard tools and equipment (e.g., wrenches, multimeters, sockets, etc.) that are manufactured to a recognized industry standard.

6. How does the repair station ensure that the equipment is in place… › 6. How does the repair station ensure that the equipment is in place…

5.2.5.1 If the repair station will be using equipment, tools, or materials other than those recommended by the manufacturer, the manual should explain the procedure it will use for determining equivalency of equipment, tools, and materials. To determine equivalency, compare the technical requirements of the special equipment or test apparatus recommended by the manufacturer with the proposed replacements. The equipment or test apparatus may look different, be made of different materials, be a different color, and so forth. However, the equipment or test apparatus must be capable of performing all necessary tests and checking all required parameters of the articles. The level of accuracy should be at least equal to that recommended by the manufacturer of the equipment/tools. Reverse engineering should include the data, drawings, testing, or reports necessary to determine that the article is equivalent to the article recommended by the manufacturer. The basis of equivalency is the requirement that the article meet the manufacturer’s standards and specifications in all respects regarding tolerances, repeatability, and accuracy.

5.2.5.2 Standard industry practice establishes that each piece of special equipment or test apparatus have a unique part number and serial number to identify it within the repair station’s inventory system. Whether the equipment or apparatus is obtained from the manufacturer or produced by the repair station, it should be identified in the system for calibration and tracking purposes.

5.2.5.3 The following questions or concerns are offered as a guide and are intended to help initiate the procedures for describing the housing, facilities, and equipment in the manual(s). They should not be considered all-inclusive. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and needs of the repair station.

1. Does the manual include a description of how the repair station operates?

2. Does the manual include a description and/or a drawing of the housing, identifying the various work facilities within the building(s) and giving a narrative description of the housing and facilities?

3. Does the description and/or layout identify areas with special requirements?

4. Does the description include a generic overview of the type of equipment?

5. When leasing or renting equipment, does the manual contain procedures describing the lease/rent process and who is responsible for managing the program, including the required calibration/verifications?

6. How does the repair station ensure that the equipment is in place and under the facility’s control when the work is performed?

3. Knowledge of the maintenance requirements for the particular… › 3. Knowledge of the maintenance requirements for the particular…

7. If the repair station is using special equipment or tools other than those recommended by the manufacturer, does the manual include procedures for determining equivalency?

8. Does the manual include a description of the stock room/area, how inventory is requisitioned for particular jobs, and how shelf life inventory is maintained?

5.3 Capability List (CL).

5.3.1 References:

• Section 145.209(d).

• Section 145.215.

5.3.2 CL. A certificated repair station (CRS) with a limited rating may perform maintenance, preventive maintenance, or alterations on an article if it is listed on a current CL acceptable to the FAA or on the repair station’s operations specifications (OpSpecs). If the repair station chooses to use a CL, the RSM must:

1. Contain procedures for revising the list and notifying the responsible Flight Standards office;

2. Include how often the responsible Flight Standards office will be notified of revisions;

3. Contain the procedures for the self-evaluation required under § 145.215(c) for revising the CL;

4. Describe the methods and frequency of such evaluations; and

5. Contain the procedures for reporting the results to the appropriate manager for review and action.

5.3.3 Revising the List. The CL itself may be included as a part of the RSM, but it is suggested that it be made a separate document for ease in revising the list without the need to revise the RSM; however, the procedures for performing the self-evaluation, revising the list, and making those revisions available to the FAA must be included in the manual.

5.3.4 Self-Evaluation.

5.3.4.1 The individual performing the self-evaluation required under § 145.215(c) should have the following qualifications:

1. Experience with performing evaluations (or audits, if that is the method selected by the repair station).

2. An understanding of the requirements of part 145.

3. Knowledge of the maintenance requirements for the particular make/model of the article to be added to the list.

5.3.8 Revising the CL.

5.3.4.2 The individual must follow the procedures in the RSM for accomplishing a self-evaluation. Checklists, working documents, and forms designed by the repair station to record the self-evaluation should be included in the forms section of the manual system. The self-evaluation should ensure that the repair station has the following:

1. The appropriate limited rating.

2. Adequate housing and facilities.

3. Recommended tools, equipment, and materials, or equivalent, as necessary to perform the maintenance in accordance with part 43.

4. Current technical data.

5. Sufficiently trained and qualified personnel.

6. Completed self-evaluation records on file.

5.3.5 Record and Report of Self-Evaluation Results. Procedures should be established for conducting the self-evaluation, recording and retaining the self-evaluation, and reporting the results to the appropriate repair station manager for review and action. The procedure used to revise the list should describe the method used to indicate any changes made to the list. Any deficiencies found during the self-evaluation should be corrected before the article can be added to the CL. When the self-evaluation establishes satisfactory results, the article may be placed on the CL. Notification of the revision to the list should be provided to the responsible Flight Standards office in accordance with the procedures required in § 145.209(d)(1). The repair station should retain documentation of the self-evaluation as long as the article is listed on the current CL. If the article was authorized in OpSpecs prior to establishing a CL, or the self-evaluation documents were missing, a baseline assessment should be documented for the current listing. For repair stations located outside the United States, the records of the self-evaluation may be in the national language; however, they must be made available to the FAA in English.

5.3.6 Person Responsible for Maintaining the CL. The procedures for revising the CL and notifying the responsible Flight Standards office should include who (by title) is responsible for maintaining the CL and communicating any revisions to the office. If the self-evaluation was satisfactory, the CL may be revised.

5.3.7 Maintaining the CL. CL currency can be shown by a List of Effective Pages (LEP) or equivalent document. The CL must identify each article by make and model or other nomenclature designated by the article’s manufacturer.

5.3.8 Revising the CL. If the repair station no longer wishes to maintain an article on its CL, the article should be deleted. The repair station must have the necessary tools, equipment, housing, facilities, and trained personnel to maintain articles on the CL at the time the work is performed. The procedures in the manual should describe how to add and delete articles from the list and how to forward the revised list to the FAA. The repair station may choose to audit the CL on a regular basis to ensure that it continues to have the

5.4.2 Chapter Information. › 145-10

housing, facilities, equipment, and technical data that meet all necessary requirements to maintain the articles listed in the document. Whenever equipment, tooling, personnel, and data must be obtained in order to perform the maintenance or alteration on an article that is going to be added to the CL, the procedures for adding the article should state how the repair station will ensure that the equipment, tooling, personnel, and data will be available when the work is being performed on the article listed.

5.3.9 Electronic Media. If the CL is maintained on electronic media, the repair station will need to work with the responsible Flight Standards office to ensure compatibility of the media, equipment, and software with that of the office. Revision procedures will need to address how the FAA will be notified of the revision.

5.3.10 Procedures Guide. The following questions or concerns are offered as a guide and are intended to help initiate the procedures in the manual. They should not be considered all-encompassing. Each facility is unique and therefore may require additional procedures to verify regulatory requirements and the needs of the repair station.

1. Who (by title) will maintain the CL?

2. How will the self-evaluation be performed?

3. Who (by title) will perform the self-evaluation?

4. How will the self-evaluation be documented?

5. How will results of the self-evaluation be reported to management and how will management review the addition of capabilities to the list?

6. How will items be added to and deleted from the list?

7. How are changes clearly indicated on the document?

8. If electronic media is used, is the hardware and software compatible with that of the responsible Flight Standards office?

9. Where and by whom will self-evaluation reports be maintained?

10. Are the self-evaluations retained by the repair station for as long as an article is listed on the current CL and what is the time period of retention after an article is removed?

5.4 Training Program Revision.

5.4.1 References:

• Section 145.163.

• Section 145.209.

5.4.2 Chapter Information. Repair stations developing a training program may use the information in this chapter as a reference. AC 145-10, Repair Station Training Programs, provides additional information on developing the repair station employee training program required under § 145.163.

5.5.2 Special Circumstances

5.4.3 Required Procedures. The RSM must include procedures required by § 145.163 for revising the training program. It must also include procedures for submitting those revisions to the responsible Flight Standards office for approval.

5.4.4 Responsibility for Revisions. The procedures should address who (by title) will be responsible for ensuring that revisions are submitted to the principal inspector (PI) at the responsible Flight Standards office for review and approval.

5.4.5 Frequency of Review. The procedures should address how often the program will be reviewed to determine if it is current and adequate for the type of maintenance being performed at the facility. Because the advancements in technology can cause aviation maintenance to change rapidly, a periodic review of training needs would be appropriate. Repair stations that have established a management review program should include the training program for review during that meeting.

5.4.6 Training Program. The training program may be documented as a section of the RSM or as a separate document within the manual system. If the training program is a separate document, that document will need to include the procedures for submission to the FAA for approval prior to implementing the training.

5.4.7 Training Program Guide. The following questions or concerns are offered as a guide and are intended to help the repair station initiate the procedures in its manual(s). They should not be considered all-inclusive. Each facility is unique and may require additional procedures to verify regulatory requirements and the needs of the repair station.

1. Who (by title) is responsible for submitting the initial training program and its revisions to the FAA?

2. When will the revision be submitted?

3. What are the procedures for submitting revisions to the responsible Flight Standards office for approval?

4. How often will the training program be reviewed for currency and completeness?

5. Who (by title) is responsible for performing the review?

6. How will revisions be recorded and implemented?

7. How will the revised text be identified?

5.5 Work Performed at Another Location.

5.5.1 Reference. Section 145.203.

5.5.2 Special Circumstances: § 145.203(a) (OpSpec D100 is not required). This section states that a repair station may temporarily transport material, equipment, and personnel needed to perform maintenance, preventive maintenance, alterations, or certain specialized services on an article for which it is rated to a place other than the repair station’s fixed locations due to a special circumstance, as determined by the FAA. Examples would be

7. The procedure used in notifying the responsible Flight Standards… › 7. The procedure used in notifying the responsible Flight Standards…

an aircraft on the ground or in preparation for a ferry flight (nonroutine maintenance or alteration actions).

Note: Normally, work performed at another location does not include working outside the country where the repair station is located. However, work performed outside the country under a special circumstance may be authorized under § 145.203(a). If work must be performed outside the country, the repair station should obtain required approvals from the country where the work will be performed and notify their responsible Flight Standards office.

5.5.2.1 If the repair station wishes to perform maintenance away from the fixed location for special circumstances, it may put a procedure in its manual for the types of special circumstances that it may need to perform. The RSM should address the following:

1. The types of and limitations on the work that would be considered special circumstances (e.g., emergency repairs, aircraft on the ground, and ferry flight preparation).

2. The estimated length of time away from the fixed location.

3. The procedure to ensure adequate personnel are chosen, including the person(s) responsible for performing, supervising, inspecting (including inspections regarding receiving/incoming, preliminary, hidden damage, in-process, and final), and approving the work for return to service.

4. If necessary, the procedure for ensuring the location will have the necessary housing and facilities for accomplishing the work.

5. The procedure for transporting any equipment, tools, materials, and data to the work site. If the equipment, tools, materials, and/or data will be obtained at the location, include the procedure used for ensuring they are received and controlled under the repair station’s quality system for the duration of their work.

6. The procedures used for storing any equipment, tools, materials, and data for the duration of the project.

7. The procedure used in notifying the responsible Flight Standards office of the request to work away and what type of information will be included in the request. Examples of information could include identifying the customer and describing the work requested or anticipated, and the location at which the work will be performed.

5.5.3 Recurring Work

8. The title of the person who will notify the responsible Flight Standards office of the special circumstance and how that notification will be made.

9. How the repair station will receive the FAA’s determination of acceptance or denial for the request to work away from the fixed location for the special circumstance.

5.5.2.2 By requesting the general determination of special circumstances and obtaining verification from the FAA (written response), the repair station will not need to request permission on a case-by-case basis. The repair station would follow its procedures and notify the FAA each time work was performed away from the fixed location for those special circumstances.

5.5.2.3 If the repair station will not perform work away from location on a recurring basis and does not include a procedure in its manual for work away from the fixed location for special circumstances, then it must submit each request to the FAA for evaluation on a case-by-case basis prior to performing the requested work. The FAA will make a determination and inform the repair station of any parameters that it must follow to perform the requested work. The request should provide the following information:

1. The types of and limitations on the work that would be considered special circumstances (e.g., aircraft on the ground, ferry flight preparation, maintenance that must be performed prior to moving an article due to an unsafe condition, etc.).

2. The estimated length of time away from the fixed location.

3. The procedure used to ensure the location will have the necessary housing and facilities for accomplishing the work when necessary.

4. The procedure used for transporting any equipment, tools, materials, and data to the work site. If the equipment, tools, materials, and/or data will be obtained at the location, include the method for ensuring they are received and controlled under the repair station’s quality system for the duration of their use on the project.

5. The procedure used for storing any equipment, tools, materials, and data for the duration of the project.

6. The FAA will make a determination and provide a written response to the repair station, which may include additional parameters or limitations that it must follow to ensure compliance with parts 43 and 145.

5.5.3 Recurring Work: § 145.203(b) (OpSpec D100 is required). If the repair station is performing maintenance away from the fixed location on a recurring basis (part of everyday business rather than under special circumstances), the RSM includes the

7. Procedures for providing or obtaining necessary equipment, tools,… › 7. Procedures for providing or obtaining necessary equipment, tools,…

procedures for accomplishing the maintenance, preventive maintenance, alterations, or specialized services at a place other than the repair station’s fixed location. This type of work could include fuel cell repair, Nondestructive Testing (NDT), mobile field services, etc., where most, if not all, of the work is completed away from the repair station’s fixed location. Procedures to govern work performed at another location in accordance with § 145.203(b) are required if the repair station performs work at another location on a recurring basis. This business practice will provide flexibility and mobility to meet industry needs and should not be restricted “only” to special circumstances. The procedures listed below are suggested, and those listed that support regulatory requirements will be noted as such with the regulation in parentheses. The manual procedures should address the following:

1. Procedures for generating work orders from the repair station’s fixed location for the scope, nature, and location (refer to § 145.209(i)).

2. Procedures for communication between and among personnel in the field and the repair station’s fixed location. The communication methodology needs to ensure the ability to transmit voice and data on a consistent basis. The ability to transmit verbal instruction and written documents is essential to establishing and maintaining continuous compliance with parts 43 and 145.

3. Procedures for analyzing the qualifications of and dispatching or obtaining personnel required for the scope and type of work anticipated and performed. Consider the following:

• General knowledge (through training and experience) and capability requirements (refer to §§ 145.151 and 145.163);

• The requirement for individual certification for supervisors and persons authorized to approve work for return to service (refer to §§ 145.153 and 145.157); and

• Ensuring persons performing inspection activities are listed on the roster and meet the requirements of § 145.155.

4. Procedures for ensuring employment summaries (refer to § 145.161(a)(4)) and rosters (refer to § 145.161(a)) are kept current and that the RSM reflects the appropriate duties, responsibilities, and authority of management (supervisory, inspection, and approval for return to service personnel) for persons authorized to work away from the fixed location (refer to § 145.209(a)).

5. Procedures for verifying the extent and nature of available housing and facilities (refer to § 145.209(c)).

6. Procedures for providing or obtaining the calibrated equipment needed to make final airworthiness determinations on the work performed (refer to § 145.211(c)(viii)).

7. Procedures for providing or obtaining necessary equipment, tools, and tooling needed to accomplish the work scope.

15. › 15.

8. Procedures for providing or obtaining the necessary maintenance data (e.g., maintenance manuals, overhaul manuals, instructions for continued airworthiness (ICA), Service Bulletins (SB), Supplemental Type Certificate (STC) data, and other information pertinent to the maintenance, preventive maintenance, and alteration activities that is acceptable to or approved by the Administrator) (refer to §§ 145.109, 145.205, and 145.211).

9. Procedures for providing or obtaining the proper replacement items (e.g., parts, subassemblies), materials (e.g., raw metals, solvents), and services (e.g., heat treat, welding). If the items are not dispatched from the fixed location, include the procedures used for receiving, performing incoming inspection, handling, and storage of items that will be used or installed (refer to §§ 145.109 and 145.211).

10. If hazardous material (hazmat) may or will be involved, the procedure for ensuring proper compliance with § 145.165 regarding an employer training program and air carrier notification.

11. Procedures for performing initial, in-process, and final inspections of the articles being worked on, if different from the procedures used at the fixed location. If different forms are used to record activities, they would be included in the forms section of the repair station’s manual (refer to § 145.211(c)(3)).

12. Procedures for obtaining, storing, and retrieving records of maintenance performed for the owner of the article being maintained (e.g., logbook) and for the repair station (refer to § 145.209(i)). If different maintenance records will be used for the repair station, they must be included in the forms section of the repair station’s manual (refer to § 145.211(c)(3)).

13. Procedures to ensure the RSM is current and available at the location where the work is being performed, and that the work is being performed in accordance with procedures in the manual.

14. Many repair stations transport equipment, tools, personnel, data, etc., from one location to another on a recurring basis. The use of mobile maintenance units is only one way to facilitate the movement from one location to another. Many repair stations that do transport the items listed above do so by “staging” a vehicle type of transportation throughout the United States in support of recurring work away from the fixed location. The “staging” of these units should not be considered a standalone or satellite repair station.

15. Although not a regulatory requirement, many repair stations ensure procedures for the work away from the fixed location on a recurring basis (refer to § 145.203(b)) using a “staging” or completely mobile method of transporting equipment, tools, personnel, data, etc., are identified within the manual system. Some examples of procedures using a mobile method of transporting are:

5.6.2 Requirements. › 135

• Is there a procedure the fixed location repair station can use to determine the location of each unit?

• Is there a procedure for identifying who (by title) will be responsible for the units (i.e., point of contact (POC))?

• Are there procedures addressing any audits the main fixed location repair station may conduct on the units to ensure that the units, personnel, equipment, tools, materials, data, etc., remain in compliance with the regulation, RSM, QCM, and training program requirements?

• Who (by title) will be responsible for conducting such audits and who (by title) will review the audit results and take any actions, if necessary, to correct discrepancies identified in the audits?

Note 1: The rule does not allow continuous, uninterrupted operations at another fixed or permanent location (facility) without applying for a new repair station or satellite certificate at that location.

Note 2: A combination of storing equipment, tools, parts, etc., and having repair station personnel positioned at a fixed or permanent location (facility) while performing maintenance on a daily basis at that location indicates a continuous, uninterrupted operation. (This does not imply that personnel who are assigned to a specific mobile maintenance unit are considered permanently positioned.) A continuous operation exists when a repair station permanently moves tools, equipment, and personnel to another fixed location and performs maintenance, preventive maintenance, alterations, or specialized services at that fixed location. A repair station that conducts these types of operations no longer meets the intent of § 145.203. If the repair station is to continue operations in this manner, then it must apply for certification as a satellite or standalone repair station.

5.5.4 Permanent Fixed Location. Additionally, work that is to be performed at another location does not include other authorizations, such as having a line maintenance authorization to perform work for an air carrier. Work performed at locations away from their fixed base allows repair stations the flexibility to meet industry needs and to be mobile when necessary. Repair stations must still maintain a permanent fixed location even if the majority of their work is done at another facility or location.

5.6 Maintenance, Preventive Maintenance, and Alterations Performed for Air Carriers Under 14 CFR Parts 121, 125, 129, and 135.

5.6.1 Reference. Section 145.205.

5.6.2 Requirements. Repair stations that perform maintenance, preventive maintenance, or alterations for an air carrier or commercial operator that has a Continuous Airworthiness Maintenance Program (CAMP) under part 121 or 135 must follow the air carrier’s or commercial operator’s program and applicable sections of its maintenance manual. In this case, this section of the manual should describe the procedures to ensure that

5.6.4.1 The inspectors performing RII for the air carrier will be…

maintenance is performed in accordance with the air carrier’s program and maintenance manual. The procedures should ensure that the air carrier has provided the repair station with the information necessary to ensure compliance with this requirement. The air carrier or commercial operator may provide the repair station with the applicable sections of its maintenance program or manuals at the time the work is performed. On the other hand, the purchase order or other contractual documents from the air carrier could clearly state the source of the data (manufacturer’s or air carrier’s manual) used to perform the requested maintenance, along with any other requirements of its program or maintenance manual. If the repair station performs an inspection for a certificate holder conducting operations under part 125, the manual should contain procedures to ensure the inspections are performed in accordance with the operator’s approved inspection program. Again, the operator may provide the repair station with the applicable sections of its inspection program or clearly outline the requirements on the purchase order.

5.6.3 Identify Responsibilities. The procedures should identify who is responsible (by title) for keeping all of the operators’ data current and where these manuals/sections will be located if retained at the repair station. The procedures also should explain what air carrier or commercial operator information must be available to maintenance personnel when the work is performed. Additional procedures should be included to ensure that purchase orders are thoroughly reviewed. This review will be necessary to ensure that the air carrier has clearly specified what technical data to use for performing the maintenance. Employees may need additional training to properly perform this review. The traveler or work-order system of the repair station may be used to integrate this information into the quality control (QC) system. If the repair station transfers requirements from the air carrier or commercial operator to its maintenance personnel by special instructions on the work order or traveler, that section of the QC system should clearly explain how this is accomplished.

5.6.4 Organization. The repair station performing maintenance for an air carrier should have an organization adequate to perform the work. This includes the ability to distinguish the work performed for different operators. Additionally, if the repair station is performing Required Inspection Item (RII) inspections, the organizational structure should provide separation of maintenance and inspection personnel. The air carrier, not the repair station, determines the maintenance actions that are RII. If the repair station’s inspectors are authorized to perform RII for the air carrier, the air carrier will ensure that the inspectors are trained on the air carrier’s RII procedures, including how the inspection is performed and recorded.

5.6.4.1 The inspectors performing RII for the air carrier will be qualified and authorized by the carrier. This authorization is usually in written format, often a card carried by the inspector. The authorization may need to be renewed, depending on the air carrier’s procedures. The procedures in the RSM should include who will maintain a list of current RII inspectors, how an inspector is added to the list, and where the list is located.

5.6.5.2 Title 14 CFR part , § defines maintenance as “inspection,… › 1.1

5.6.4.2 The repair station should request information from the air carrier or commercial operator pertaining to at least the following issues:

• RII;

• Training requirements for the work being performed on the operator’s behalf, including who will provide the training;

• Maintenance duty time requirements;

• Special maintenance or alteration instructions per engineering orders, build lists, and other methods, techniques, and practices in the operator’s manual per part 43, § 43.13(c); and

• Recording requirements, including who is responsible for maintaining the files.

5.6.5 Line Maintenance Authorization. The FAA may grant approval to an existing and appropriately rated CRS to perform for an air carrier the type of maintenance that meets the line maintenance definition of § 145.3(d). This approval includes, but is not limited to, locations outside the repair station’s primary housing location required in § 145.103(a). A repair station may hold a line maintenance authorization only if the repair station already provides housing as required by § 145.103(a). A repair station certificated to perform maintenance on the aircraft or engine under a class or limited rating may be authorized to perform line maintenance functions at other locations as listed on OpSpec D107, Line Maintenance Authorization. For a repair station authorized to have multiple locations across geographic boundaries, the PI will develop a surveillance program that encompasses all facilities of the repair station, regardless of location. A line maintenance authorization location may be located at an airport outside the United States; however, the PI will ensure that the surveillance program also encompasses the location.

Note: This may be accomplished by requesting assistance from the responsible Flight Standards offices and/or International Flight Standards Offices (IFO) who perform surveillance activities located in the geographic area where the line maintenance is being performed.

5.6.5.1 To be issued a line maintenance authorization, the repair station must show the capability to perform the limited scope of work defined in § 145.3(d) at each location. After the showing has been made, the repair station will perform maintenance in accordance with § 145.205.

5.6.5.2 Title 14 CFR part 1, § 1.1 defines maintenance as “inspection, overhaul, repair, preservation, and the replacement of parts, but excludes preventive maintenance.” Alterations are not included in the regulatory definition of maintenance and are therefore not included in the privileges provided for in § 145.205(d). However, under the current definition of line maintenance provided for in § 145.3(d)(2), a repair station holding a line maintenance authorization may perform scheduled checks that contain servicing and/or

Note › Note

inspections that do not require specialized training, equipment, or facilities, and may constitute a preventive maintenance action.

5.6.6 Line Maintenance Requirements. The repair station’s equipment, tools, and materials necessary to perform the line maintenance must be located on the premises and under the repair station’s control when the work is being done. If the repair station is going to perform line maintenance, its manual should include procedures to ensure that the necessary equipment, technical data, and trained personnel are available before the maintenance can be performed. This should include who (by title) will be responsible for ensuring that the necessary equipment, technical data, and trained personnel will be available when the work is being performed.

5.6.7 Coordination with the Air Carrier. The repair station’s training program can be conducted in coordination with the air carrier. The specific training an employee receives should be recorded in the employee’s training record. The procedure will need to include who (by title) is responsible to ensure that training is conducted and recorded. The repair station should maintain a list of individuals who are trained by the air carrier to perform line maintenance. Although air carrier maintenance requirements may be incorporated into the repair station’s training program, the repair station must follow its training program requirements with respect to conducting the training, recording the training in employee training records, and qualifying those individuals authorized to perform line maintenance for an air carrier. Air carrier training does not relieve the repair station from the requirement to ensure its personnel are trained for the maintenance it is rated to perform.

5.6.8 Initiate Development. Addressing the following concerns (if applicable) will initiate development of the procedures for performing maintenance for an air carrier:

1. Who is responsible (by title) for keeping a file of the air carrier’s procedures, including the necessary technical data?

2. Who is responsible (by title) for review and amendment of purchase orders for complete and correct instructions? Is that person trained?

3. Who will maintain the list of current RII inspectors?

4. Does the RSM include procedures to ensure that the necessary equipment, trained personnel, and technical data will be available for line maintenance?

5. Who is responsible for coordinating the training program with the air carrier?

6. Does the repair station roster include authorization for individuals performing line maintenance and RII?

7. How does the repair station ensure that personnel comply with its manual and appropriate sections of the air carrier’s manual, regardless of location?

Note: The authority to perform line maintenance for an air carrier is not a rating but an authorization. A CRS must have established housing and facilities that meet the requirements of part 145 for the ratings issued in order to make application for a line maintenance authorization. If line maintenance is the only

5.7.2 Contract Maintenance Functions. › 43.9

maintenance a repair station is authorized to perform, the repair station must still meet the housing and all other applicable requirements of part 145. Housing need not be on the airport where the line maintenance is performed, but the street address must be listed on the repair station’s Air Agency Certificate and OpSpecs.

5.6.9 Notifications of Hazmat Authorizations. Procedures should address that:

1. Prior to performing maintenance on or on behalf of a part 121 or part 135 certificate holder, the repair stations must acknowledge that they have received notification from that certificate holder required under part 121, § 121.1005(e) or part 135, § 135.505(e).

2. Prior to performing work on or on behalf of the part 121 or part 135 air carrier, the repair station has notified its employees, contractors, or subcontractors that handle or replace aircraft components or other items regulated by Title 49 of the Code of Federal Regulations (49 CFR) parts 171 through 180 of each certificate holder’s OpSpec authorization permitting or prohibiting the carriage of hazmat in accordance with § 145.206.

3. Prior to performing maintenance, repair stations that meet the definition of a hazmat employer under 49 CFR part 171, § 171.8 must have a hazmat training program that meets the training requirements of 49 CFR part 172 subpart H.

4. Repair station employees may not perform or directly supervise a job function listed in § 121.1001 or § 135.501 for, or on behalf of, the part 121 or part 135 operator, including loading of items for transport on an aircraft operated by a part 121 or part 135 certificate holder, unless that person has received training in accordance with § 145.165.

Note: Refer to the FAA’s Office of Hazardous Materials Safety (ADG) website for additional information: http://www.faa.gov/about/office_org/headquarters_offices/ ash/ash_programs/hazmat/.

5.7 Contract Maintenance Information.

5.7.1 References:

• Section 145.201.

• Section 145.209(h).

• Section 145.211(c).

• Section 145.217.

5.7.2 Contract Maintenance Functions. The regulations enable a repair station to contract maintenance, preventive maintenance, or alteration for which it holds a rating, in accordance with § 145.201(a)(2). Contract maintenance functions, which require FAA approval under § 145.217(a), are only required if the repair station extends its privileges to the contractor and provides for return to service under § 43.9. In this circumstance, the

Note › Note

originating repair station chooses to exercise the privileges of its certificate and assumes responsibility for the work performed by the contractor.

5.7.2.1 To be considered a contract maintenance function that requires FAA approval, the repair station must meet both of the following conditions:

1. Entering into an agreement with another person or entity (FAA certificated or noncertificated) to perform maintenance functions on an article; and

2. The repair station chooses to exercise the privileges of its certificate and assumes responsibility for the work performed by the contracted person or entity.

5.7.2.2 In order for the repair station to contract a maintenance function, the repair station must:

1. Be certificated and appropriately rated to perform the maintenance functions to contract out.

2. Take regulatory responsibility for issuing an approval for return to service under § 43.9 for the maintenance function performed by the contractor.

3. Obtain approval of the listed maintenance functions in accordance with § 145.217 and make that list available to the FAA in accordance with the procedures in § 145.209.

4. Ensure and have procedures that qualify the sources to which it contracts those maintenance functions in accordance with § 145.201(a)(2) (QC system).

5. Have procedures and maintain a current list of those contractors in accordance with § 145.217 and make the list available to the FAA in accordance with § 145.209.

6. Ensure that it has procedures to perform the incoming inspection, final inspection, and return to service of articles in accordance with the pertinent subparagraphs of § 145.211(c)(1).

7. Provide a procedure that confirms by inspection or test that the work (i.e., maintenance function) was performed satisfactorily and the article is Airworthy before approving it for return to service.

8. Ensure the contract allows the FAA to make an inspection and observe the performance of the person’s work on the article.

Note: Purchase of maintained parts from another repair station (including exchanges), brokerage, and using another CRS to perform work that is outside the original repair station’s ratings are not maintenance functions requiring FAA approval. These are instances where the purchasing repair station is not exercising the privileges of

5.7.4.2 The repair station may also wish to provide a list of those…

its certificate. When a repair station requests work or sells a previously maintained article (including type certificated (TC) products), it is acting solely as a distributor. Although the purchasing repair station may induct the part through its receiving inspection process, it is merely relying on the work previously performed at another certificated entity and is not exercising the privileges under § 145.201(a)(2).

5.7.3 Contract Maintenance Information Required by § 145.217. The RSM should contain procedures for maintaining and revising the contract maintenance information required by § 145.217. This information is required for contracting to both FAA-certificated and noncertificated facilities. The information required includes the approved maintenance function to be contracted, the name of each outside facility to which the repair station contracts such maintenance, and the type of certificate and ratings held, if any. The QCM/section should describe the system and procedures used for qualifying both FAA-certificated and noncertificated entities and surveilling noncertificated entities who perform maintenance, preventive maintenance, or alterations for the repair station. These procedures may be contained in one manual or in separate documents that are part of the manual system.

5.7.4 Material and Equipment. A repair station must have the material and equipment necessary to perform the functions appropriate to its rating. However, it need not have the tools and equipment for functions it is authorized to contract out pursuant to its FAA-approved maintenance functions. When exercising the privileges of its certificate, a repair station may contract maintenance functions to FAA-certificated facilities and non-FAA-certificated entities only if the maintenance functions are approved by the FAA. The repair station must request approval before it can contract a maintenance function. If the FAA approves the contracted maintenance function, the repair station will determine who performs the maintenance.

5.7.4.1 The types of maintenance functions that the repair station may wish to have approved fall into two categories. First, the types of maintenance functions that must be contracted because the repair station does not have the housing, facilities, materials, or equipment available on its premises and under its control. These may include plating, heat treatment, special NDT or inspection, or the maintenance or alteration of components or subassemblies. This list should be categorized broadly, such as specialized services or components of articles for which the repair station has the overall rating.

5.7.4.2 The repair station may also wish to provide a list of those maintenance functions for which it has the housing, facilities, equipment, and materials in-house, but may need to contract to another facility because of workload or emergency situations. For example, an airframe-rated repair station may have the capability to perform maintenance or alteration on landing gear, but if the in-house facility cannot accomplish the work scope within a specified time, it may want to contract that work to another facility. It would not be able to

1. The noncertificated person follows a QC program equivalent to the… › 1. The noncertificated person follows a QC program equivalent to the…

contract the work unless the maintenance function of landing gear maintenance was on its FAA-approved maintenance function list.

5.7.4.3 Additionally, the repair station may wish to provide a method for which a maintenance function can be added to its FAA-approved function list on an emergency basis. This would be accomplished by explaining how the maintenance function would be added and how the FAA approval would be obtained in a short period of time. The repair station should coordinate closely with its PI and its responsible Flight Standards office regarding these emergency procedures.

5.7.5 Establish Procedures. Before contracting out a function, the repair station should establish:

1. Procedures to obtain approval for the maintenance function.

2. Procedures to qualify the contractor.

3. Procedures to surveil the contractor if the contractor does not perform approval for return to service.

4. A list of contractors and procedures to properly maintain that list.

5. Technical training on contracted functions for receiving inspection personnel.

6. Procedures for receiving inspections that provide enough technical detail to determine acceptability of an article.

7. Procedures for complying with the test and/or inspection requirement of § 145.217(b)(3) when contracting to a noncertificated person.

5.7.6 Contracting to FAA-Certificated Facilities. A CRS may not provide only approval for return to service of a complete TC’d product following contract maintenance, preventive maintenance, or alterations. If the repair station chooses to exercise the privileges of its certificate by issuing an approval for return to service for a maintenance function contracted to an FAA-CRS, the repair station must determine that the contracted repair station is properly rated to perform the maintenance. A repair station may issue an additional approval for return to service under its privileges, such as tagging a previously maintained or altered article as inspected, provided the repair station:

• Has the appropriate rating for the article;

• Is approved to contract out the maintenance function; and

• Conducts the maintenance, preventive maintenance, or alteration, including inspection in accordance with § 43.13 and part 145.

5.7.7 Contracting Maintenance Functions to Noncertificated Persons. If the repair station contracts to noncertificated persons, the repair station must ensure that:

1. The noncertificated person follows a QC program equivalent to the FAA-CRS’s system with respect to the work being performed for the CRS;

5.7.12 Initiating Procedures.

2. The repair station remains directly in charge of the work performed;

3. The repair station verifies by inspection or test that the work was performed satisfactorily; and

4. The article is Airworthy with respect to the work performed by the noncertificated person.

5.7.7.1 The repair station must verify by test or inspection that the work has been performed satisfactorily and that the article is Airworthy before approving it for return to service.

5.7.8 Procedures. Procedures in the RSM should include the title of the person responsible for the contract maintenance program. The procedures must also include provisions for maintaining the contracting information in a format acceptable to the FAA. The information is not required to be in the manual, but if included, it must identify:

• The name of each outside contracted source;

• The maintenance function(s) contracted to each source; and

• The type of certificate and ratings, if any, held by each source.

5.7.9 Initial Qualification. The procedures in the RSM must describe how the noncertificated person is initially qualified. It also should describe how the repair station ensures that the noncertificated person continues to follow the QC program equal to the repair station’s for the work being performed on the repair station’s behalf.

5.7.10 Coordinating Communications. Procedures for coordinating communications between the repair station and the contracted source should be established. If the repair station performs any maintenance for an air carrier, the procedures should explain any special requirements (such as performing the work in accordance with the air carrier’s program). Procedures should describe how the repair station would address any problems with quality or delivery. Any recurring problems should be addressed in the corrective action program.

Continue reading ↓ 120 of 230 passages shown