DEPARTMENT OF TRANSPORTATION ORDER FEDERAL AVIATION ADMINISTRATION 6930.22

DEPARTMENT OF TRANSPORTATION ORDER FEDERAL AVIATION ADMINISTRATION 6930.22

7 June 1971

SUBJ: SPECIFICATION FAA-E-247O, TRANSPARENT PLASTIC WINDOW SHADES

1. PURPOSE. This order announces the availability and application of Specification FAA-E-2470 dated 17 May 1971 which describes transparent plastic window shades for airport traffic control tower cabs and similar agency operational facilities.

SUBJ: SPECIFICATION FAA-E-247O, TRANSPARENT PLASTIC WINDOW SHADES

2. DISTRIBUTION. This order is distributed in Washington headquarters to Facility Installation, Air Traffic, Airports, Logistics, Systems Maintenance, and Systems Research and Development Services to division level; Regions, Aeronautical Center, and NAFEC to division level; Regional Airway Facilities Division and Air Traffic Division to branch level; Combined Station/Towers, Airport Traffic Control Towers and Flight Service Stations.

3. CANCELLATTON. This new specification supercedes Specification FAA-E-2328, Plastic Window Shades, dated 4 January 1968.

4. APPLICATION. Specification FAA-E-2470 incorporates desirable improvement in the quality of the shade material specified, including the rollers, hardware and installation techniques associated therewith. This specification shall be used for the procurement and installation of window shades for all airport traffic control tower cabs.

CharlroH. Newpol CHARLES H. NEWPOL

Acting Deputy Director, Facility Installation Service

Distribution: WFI/AT/AS/LG/SM/RD-2; RCN-2; RAF/RAT-3; FAT-3; Initiated By: FI-410 FAT-2; FAT-5(Minimum): MAF/AT-2 38230

MHY-25-1999 10:37 SETA DCC P.02/05

FAA-E-2470b December 5, 1985 SUPERSEDING FAA-E-2470a, 4/30/76

10A TECHNICAL UNIT JUN 11 1986 DOT LIBRARY M493.2 DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION SPECIFICATION

TRANSPARENT PLASTIC WINDOW SHADES

TRANSPARENT PLASTIC WINDOW SHADES

1. SCOPE 1.1 Scope - This specification sets forth the requirements for material, direct and reflective glare and to contribute to temperature control of tower cabs. Shades shall be installed on all exposures of the cab. fabrication, and installation of transparent plastic window.shades for use in Airport Traffic Control Tower (ATCT) cabs." These shades are required to reduce the sun's

2. APPLICABLE DOCUMENTS

2. APPLICABLE DOCUMENTS

a conflict between requirements of this equipment specification and documents listed or referenced herein, this specification shall have precedence. effect on the date of the invitation for bids or request for proposals, form a part of this specification and are applicable to the extent specified herein. In the event of 2.1 Federal Publications - The following Federal publications, of the issues in

2.I.1 Federal Specification - L-P-377b - Plastic Sheet and Strip Polyester proposals. Requests should cite the invitation for bids, request for proposals, or the contract involved or other use to be made of the requested material.) (Copies of this specification may be 'obtained from the Contracting Officer in the Federal Aviation Administration office issuing the invitation for bids or request for

obtained from General Services Administration offices in Washington, D.C.; Seattle; San Francisco; Denver; Kansas City, MO; Chicago; Atlanta; New York City; Boston; Dallas; and Los Angeles.) (Information on obtaining copies of Federal specifications and standards may be 2.1.2 Federal Standard - FED-STD-102 - Preservation, Packaging and Packing Levels

MHY-25-1999 10:57 SEIA DCC P.03/05

MHY-25-1999 10:57 SEIA DCC P.03/05

FAA-E-2470b December 5, 1985

2.2 Other Publications - The following publication, of the issue in effect on the date of the invitation for bids or request for proposals, forms a part of this specification and is applicable to the extent specified herein.

2.2.1 AIMCAL Standard Methods (Copies of the Association of Industrial Metalizers, Coaters and Laminators (AIMCAL) Standard Methods may be obtained from AIMCAL, 61 Blue Ridge Road,. Wilton, CT 06897 (203-762-5611).

3. REQUIREMENTS

3. REQUIREMENTS

3.1 Materials to be Furnished - Material furnished by the contractor shall be complete in accordance with all specification requirements and shall include the following items.

3.1.1 Transparent Plastic Shade Material - Shade film shall be manufactured from a polyester type polymer in accordance with Federal Specification L-P-377b dated February 28, 1966 for Type V (DuPont's "Mylar" clear sheet film or approved equal).

film construction shall be in accordance with Madico, Inc. of Woburn, 3.1.2 Transparent Plastic Shade Film Construction - The transparent plastic shade

consist of four-ply laminated polyester film. The two laminated center sheets shall Massachusetts Type SSLW-500-SR/Gray/SR or approved equal. Shade product shall each be 1.5 mil thick polyester vat dyed gray in color meeting the Martin Processing Co. of Martinville, VA specification (Gray dye, reference #8301 and laminate reference #51012) or approved equal. A clear 1 mil thick polyester film shall be laminated to each side of the gray dyed film laminate. Both exposed sides of the shade film surfaces shall be protected with a scratch resistant coating- The final film construction will be 5 mils thick, optically clear and totally transparent. Surface tinting and/or colored adhesives will not be an acceptable equal without independent reports qualifying the color stability in comparison with the vat dyed process.

3.1.3 Shade Solar Optical Properties

3.1.3 Shade Solar Optical Properties

3.1.3.I Visible Light Transmission - The shade shall transmit no more than 6% of the visible solar energy (from 380 to 780 nanometers) when measured by the methods. Association of Industrial Metalizers, Coaters and Laminators (AIMCAL) standard

3.1.3.2 Ultra-Violet Transmission - The shade shall transmit no more than 4% of the ultra-violet solar energy (from 300 to 380 nanometers) when measured by AIMCAL standard methods.

3.1.3.3 Total Solar Energy Rejected - The shade shall reject 48% of the total solar energy transmitted from 360 to 2100 nanometers when measured by AIMCAL standard methods.

RHY-25-199910:38 SETA DCC P.04/05 • December 5, 1985 FAA-E-2470b

hemline bar to cover any sharp exposed edges. cord and shade are attached. Black plastic caps shall be provided on each end of full width metal hemline bar, (minimum of 26 gauge) at bottom onto which the pull 3.1.4 Bottom Bar - Shades shall have a flat one-inch by one-half-inch, dull black,

3.1.5 Shade Cords - Shall be color black and of sufficient length to route around be 9/64" diameter rope made of 4.5 Duro Nylon or approved equal and shall be attached underneath the center of the bottom of the hemline bar. stairwell and equipment to cord lock positions whenever required. The cords shall

3.1.6 Shade Rollers - Shades shall be mounted on 1 3/4" diameter metal wrapped rollers. The rollers shall be spring loaded, single piece barrel, with a reusable safety cotter key type retainer installed through both end pins and washers to prevent roller from falling out of mounting brackets. Constant tension in shades is

pointing to the proper installation direction of the roller into the mounting B, or approved equal with a 2% inch resting ledge. Regular "industry norm" ceiling brackets are not acceptable. A label stating "THIS END DOWN" with an arrow brackets shall be placed on the spring motor end of each shade roller. The shade required. Mounting brackets shall be Plastic View, Van Nuys, CA, PV 128-205A. and

film laminate material shall be mounted on rollers so as to minimize ridgings. Roll-off direction of material from roller shall be as directed by the shade manufacturer for use in the specific tower cab under consideration. Each shade shall have a label or whatever suitable means required to specify and identify the proper roll-off direction.

3.1.7 Shade Labels - Each shade shall have a manufacturer's label attached to the metal bar hemline giving cleaning instructions and the telephone number for emergency service.

3.1.8 Lock Pulley and Cord Direction Change Pulley - Lock pulleys shall consist of a roller and a spring return side action cam cord grip #R359 Britain, Merriman, Co. Millersville, MD or approved equal. Cord direction change pulleys #PV-128route shade cord around obstructions where they exist. Pulleys shall be positioned CDC/57-1006/8 Plastic View, Van Nuys, CA or approved equaI shall be used to in direct line with cord outlet on metal hemline.

3.2 Fabrication 3.2.1 Shade Size - Shade roller width shall be to within inch of maximum possible width as determined by physical limitations. Shade material width with shade fully drawn shall be to within' 1 inch of columns on bias cut sides and to within 1 3/4 inch of columns on vertical cut sides. Horizontal seam shall be located a minimum of 55 inches from the bottom of the shade. S' ades in ATCT cabs shall be bias cut when required. To insure a safe roll-up, a minimum of 15" of shade material shall remain on the roller when the shade is fully extended.

MAY-25-1999 10:38 SETA DCC P.05/05

MAY-25-1999 10:38 SETA DCC P.05/05

FAA-E-2470b December 5, 1985

3.3 Measuring for Shades - Measuring for shades and positioning shall be strietly in accordance with the shade manufaeturer's instructions. Marks showing the precise position of all brackets, pulleys, and metal hemline positions as related to the factory measuring instructions shall be provided. All measurements shall be taken per instruetions from shade manufacturer.

3.4 Installation - Shades shall be installed in shade recess pockets or on wood or metal plates. Shades shall follow the slope of eab glass as closely as practical within physical limitations of air ducts and other equipment. No drilling is to be done in vertical uprights of cab, as some uprights contain electrical cables. Spring tension in roller shall be manually adjusted so that shades roll up comfortably. In order to safely control and limit the shade travel, the installer shall make two knots in the shade cord. One knot is to be placed before the lock pulley to prevent the metal hemline bar from hitting the window sill. The second knot is to be plaeed after the loek pulley to prevent the metal hemline bar from hitting and overrunning the shade roller. Adherence to the "THIS END DOWN" label when installing shade will prevent improper roller installation which ean result in a locked shade situation when the metal bar hemline is near the lock pulley and cannot be pulled down to release the spring motor cam lock.

4. QUALITY ASSURANCE PROVISIONS

4. QUALITY ASSURANCE PROVISIONS

4.1 Shop Drawings- The contractor shall submit shop drawings based on actual site conditions, material lists, an 8" x 10" or larger sample of shade material, and a hand sample model of the roller and hardware for inspection prior to the fabrication of shades.

4.2 Warranty - The contractor shall furnish the Government with three (3) certified copies of the product warranty that certifies that all the specification requirements have been met.

5. PREPARATION FOR DELIVERY

5. PREPARATION FOR DELIVERY

5.1 Packaging- - Packaging shall be in aecordance with FED-STD-102, Level "B". Shades shall be packaged to afford adequate protection against deterioration and damage during shipment. The supplier may use his standard practice when it meets these requirements.

6. NOTES

6. NOTES

6.1.1 Smaller Rollers - The requirement for a 1 3/4" diameter roller (section 3.1.6) shall not apply for shades being installed in portable type airport traffic control towers or in installations where physical constraints restriet the proper operation of the shade; however, the roller diameter shall be as large as possible to allow the shade material to negotiate the roller radius without damage.

6.1.2 - Notification on Concurrence - The Contracting Officer in the Federal Aviation Administration office issuing the invitation for bids shall be notified if the 1 3/4",diameter roller cannot be used. Concurrenee from the Contracting Officer shall be required prior to contract award.

page 4 TOTAL P.05