ORDER 6650.8

AIRPORT FIBER OPTIC DESIGN GUIDELINES

AUGUST 14,1989

u.s. DEPARTMENT OF TRANSPORTATION

FEDERAL AVIATION ADMINISTRATION

Distribution: A-W (PS/SErrR/AS) -3; A-W(FS) -2; A-X(AF/AT/AS) -3; A-Y(DE) -2; A-Z(TE/AS/AN) -2; A-FAF-2/3/7 (STD)

Initiated By: APS-130

8/14/89 6650.8

3

FOREWORD

This order provides the basic procedures and guidance for the design of a fiber optics network at airports. It further provides for the selection of specialized components for a fiber optics system to interconnect air traffic control, communications, navigation and surveillance facilities.

Robert E. Brown Director, Program Engineering Service

Page i (and ii)

5

CHAPTER 1. INTRODUCTION

1. Purpose 2. Distribution 3. Scope 4 . Background 5. Environmental Conditions 6.-19. Reserved

TABLE OF CONTENTS

CHAPTER 2. FIBER OPTICS AS A COMMUNICATIONS MEDIUM

20. Introduction 21. Advantages of Fiber Optic Cable 22. Basic Elements 23. Fiber Types 24. Light Sources and Detectors 25. Optical Collection Factor 26. System Design 27. Cabling Design Considerations 28. Fiber Optic Cable Installations 29.-39. Reserved

CHAPTER 3. FIBER OPTIC CABLE LOOP SYSTEMS

SECTION 1. BASIC REQUIREMENTS

40. Characteristics

41. Master-Slave Relationship 42. Time-Division Multiplexing

SECTION 2. DETAILED REQUIREMENTS

43. System Design Considerations and Procedures 44. Cable 45. Airport Loop System Design 46.-59. Reserved

APPENDIX 1. CONFIGURATION GUIDELINES (23 Pages)

APPENDIX 2. ACRONYMS, UNITS OF MEASURE AND RELATED DOCUMENTATION (3 Pages)

APPENDIX 3. GLOSSARY (17 Pages)

APPENDIX 4. ALPHABETICAL INDEX (5 Pages)

Page No.

1

1 1 1 1 1 1

3

3 3 4 5 7 8 9 14 16 19

21

21

21

24 27

27

27 32 33 46

1

1

1

1

Page iii

6

6650. 8

LIST OF ILLUSTRATIONS

Figure

2-l. 2-2. 2-3. 2-4. 2-5. 2-6.

3 -l. 3-2. 3-3. 3-4. 3-5. 3-6. 3-7. 3-8. 3-9. 3-10. 3-11. 3-12. 3-13 . 3-14. 3-15. 3-16. 3-17.

2-l. 2-2. 2-3. 2-4.

3-l. 3-2.

Optical Fiber Cross-Section Three Types of Optical Fiber A Fiber's Acceptance Cone Half-Angle

Sources of Transmission Loss in an Optical Link Typical Fiber Optic Cable Loss Conditions

Examples of Loose and Tight Buffer Construction

Ring Bus Configuration Two Counter-Rotating Rings Dialog Between ATCT and Another Facility Manchester "M" Encoding Scheme Detailed Communication Loop Layout Existing and Planned Facility Locations Identification of Existing and Planned Cable Runs Proposed Loop Duct System Fiber Optic Loop Link Losses for Three Loops

Cable Routing within the ATCT ATCT Facility Typical Equipment Layout Demarcation Box Summary Source/Destination Summary for Loop 1 Determination of Fiber Requirements Type of Fiber Optic Cable and Recommended Installation Method Programmable Logic Controller Selection Criteria Standard Input/Output Configuration of Channel Bank Unit

LIST OF TABLES

Optical Performance of Typical Graded-Index Fibers Loose and Tight Buffer Tradeoffs Strength Member Comparison of Different Materials Tradeoffs of Various Jacketing Materials

Airport Signal Types

Classifications of Fiber Optic Cable

Page iv

Page No.

4 6 8 9 11 14

22 23 25 26 35 37 39 40 41 42 43 45 46 47 50 51 51

Page No.

9 15 16 17

29 48

7

8/14/89 6650.8

CHAPTER 1. GENERAL

1. PURPOSE. This order supplements Order 6950.23A, Cable Loop Systems at Airport Facilities, which established the program, planning and implementation for airport cable loop systems. This order further provides guidance towards the design of the fiber optics cable loop at airports as well as the selection of the specialized components of the fiber optics system.

2. DISTRIBUTION. This order is distributed to branch level in Program Engineering, Systems Engineering and Program Management, Air Traffic Plans and Requirements Services, the Office of Airport Standards and to division level in the Office of Flight Standards in Washington headquarters; to branch level in regional Airway Facilities, Air Traffic and Airports divisions; to division level in the FAA Depot at the Mike Monroney Aeronautical Center; to division level in the Systems Maintenance Service, Test and Evaluation, Aircraft and Airsystems Technology, and

Facilities Divisions at the FAA Technical Center; and to all Airway Facilities sectors, sector field offices, sector field units and sector field office units.

3. SCOPE. This guideline applies to all Level III, IV and V airports, and in particular, those airports included in FAA Order 6950.26, Airport Selection Criteria

for Power and Signal Distribution.

4. BACKGROUND. The following describes briefly the goals of the cable loop program and the rationale supporting the goals.

a. Modernization. The FAA is modernizing the National Airspace System (NAS). The goals of this modernization program are to increase the capacity of the national airspace, to enhance the safety of airspace operations, to increase the productivity of the FAA facilities operations, and to improve the cost effectiveness of the NAS operations. An overall upgrading of facilities and equipment reliability will contribute to these goals. Installing highly-reliable fiber optic loop communications systems at FAA faciltties is part of this modernization process.

b. Airport Cable Loop Designs. Airport cable loop designs allow the simultaneous bi-directional transmission of signals using multiple fibers. This provides inherent redundancy and increased reliability. The loop design may in fact be hybrid in nature and contain within the network, point-to-point segments other

than fiber, such as radio frequency (RF) segments.

5. ENVIRONMENTAL CONDITIONS. Refer to the appropriate maintenance handbook for the proper environmental conditions for operating, storage and installation of specific equipment referenced herein.

6.-19. RESERVED.

Chap 1 Par 1 ~Page 1 (and 2)

9

8/14/89 6650. 8

CHAPTER 2. FIBER OPTICS AS A COMMUNICATIONS MEDIUM

20. INTRODUCTION. Fiber optics is a collective term that includes optical fibers, cables, connectors, couplers/splitters, transmitters and receivers. Digital or analog signals are transmitted by modulating an opto-electronic source, e.g. a light-emitting diode (LED) into one end of a fiber optic cable and detecting the modulation at the far end of the cable. Many signals can be multiplexed, using time-or frequency-domain division, on a single fiber, or if the bandwidth requirement dictates can be transmitted individually. Fiber optic cables are now standardized, readily available and are suitable for duct installation or direct earth burial (DEB). For further information on fiber optic cable for airport applications, refer to FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable.

21. ADVANTAGES OF FIBER OPTIC CABLE. Several advantages result from using fiber optics cable for communication systems. Some of these are listed below:

!rrmunity to EM! and lightning:

Wide bandwidt"h 1:

Low signal loss:

Transmitter is electrically

isolated from the receiver:

Small physical size and weight:

Low cost:

Collocation with power cables: (i n compl i ance with NEC, 1987, Article 770.)

Secure:

Safe:

No need for ground:

Cable is unaffected in extreme electromagnetic

interference (EM!) environments.

Up to 800 MHz-km per fiber using the cable specified by FAA-E-2761a.

As low as 1 dB/km using the cable specified by

FAA-E-2761a.

Simplifies link design because there are no ground

loops. There are no requirements for maintaining a reference potential such as "ground".

Cables containing as many as 6 fibers in individual protective jackets are less than 1/2-inch in diameter, and often can be pulled into existing ducts, an advantage, especially when there would be

insufficient room for copper conductors.

Fiber optic links compete effectively with other digital point-to-point communication systems, and offer the advantage of longer service life and reduced installation costs.

Totally dielectric cables may be collocated in the same trench, safe from induced voltages from adjacent power cables.

No energy is emitted from a fiber optic cable.

May be used in an explosive atmosphere with no hazard.

Nonmetallic fiber optic cable does not require grounding.

1. Component of the system bandwidth calculation attributed exclusively to the fiber.

Chap 2 Par 20 Page 3

10

6650.8 8/14/89

a. Airport Communications. Fiber optics is especially attractive for airport communications because it is not susceptible to, nor does it emit interfering signals. It is able to accommodate all facility communications equipment on just a few fibers and existing fiber optic capacity can be expanded through the use of multiplexers, thereby avoiding future trenching and material costs.

b. Loop Systems. Loop systems are one or more transmission systems having closed paths that provide inherent redundancy in the event that any single link is severed. For airport cable loop systems, the options for loop configurations, the communication protocols used to determine communication priorities, and the construction of the fiber optic loops are all essentially site dependent. The basic requirements for each are discussed in greater detail in chapter 3.

22. BASIC ELEMENTS. This paragraph describes the physical make-up of optical fiber, and discusses characteristics of the types of optical fibers in use today.

a. Fiber Structure. The three basic parts of an optical fiber are shown in a cross-section view on figure 2-1.

FIGURE 2-1. OPTICAL FIBER CROSS-SECTION

---- CORE

1---- CLADDING

~--- COATING

(1) Core. The core is the central part of the fiber through which light is transmitted. The amount of light coupled into a fiber is directly proportional to the square of the diameter of its core.

(2) Cladding. Cladding is an outer layer of glass, the optical properties of which, complement those of the core to facilitate the transmission of light down the fiber. The relatively large diameter of the cladding makes the fiber easier to handle when a splice is to be made or the fiber is to be prepared for an interface

connection.

(3) Coating. Coatings are usually multilayers of plastic applied to absorb shock and provide protection from abrasion. These coatings are available from 250 microns to 1000 microns. Mechanically or chemically strippable coatings are commercially available.

11

8/14/89 6650. 8

b. Fiber Size. The size of an optical fiber is commonly referred to by the outer diameter of its core and cladding. For example: 50/125 indicates a fiber with a core of 50 microns, and a cladding of 125 microns. Coating is not normally referred to since it is not essential to the actual transmission of light although it does enhance transmission characteristics. It is normally removed when joining or connecting fibers. One micron (~m) is equal to one-millionth of a meter and for comparison, a sheet of paper is approximately 125 microns thick.

23. FIBER TYPES. Fiber types can be distinguished by the number of possible paths for light rays to travel within the fiber core. Fiber types are discussed in terms of modes, single mode or multimode. A mode is one of many possible solutions to the wave equation that is derived from Maxwell's equations. The superposition of modes result in composite waves, the normal projection of which are rays. A ray exists for each of the composite waves.

The first type of fiber to be discussed is single-mode (sometimes called monomode) fiber. It provides only a single path along which light rays may travel. See figure 2-2a. There are two types of multiple-mode (multimode) fibers. These are called graded-index and step-index fibers and are shown in figure 2-2b and 2-2c respectively. FAA-E-2761a specifies graded-index fiber. Discussion of the other types of fiber are for interest only so that the reader may gain a better understanding of basic fiber types and why one type is preferable in airport applications to other types.

FIGURE 2-2. THREE TYPES OF OPTICAL FIBER 0_.

a) Single Mode (Monomode)

CLADDING CORE

b) Graded Index (Multimode)

c) Step Index (Multi mode)

12

6650. 8 8/14/89 a. Step-Index. Step-index multimode fiber derives its name from the distinct, step-like difference in the refractive index of the core and the cladding. Common step-index fibers have core diameters of 100, 200 and 300 microns. Step-index fiber limits the system bandwidth to approximately 20 MHz'km

b. Graded-Index. Unlike step-index fiber, the profile of the index of refraction is approximately parabolic. Figure 2-2b shows a representative profile as well as the effect that this grading has on the light rays travelling down the fiber. The limitation of system bandwidth attributable to graded-index fiber is on the order of 1 GHz·km. Graded-index fibers are commercially available with core diameters of 50, 62.5, 85 and 100 microns.

c. Single Mode. The single mode fiber allows only a single mode to be efficiently transmitted. This eliminates any limitation attributable to intermodal effects. The core of a single mode fiber is extremely small, approximately six to ten microns. The single mode fiber has a significantly higher information carrying capacity than either of the two multimode types, and its bandwidth extends into the tens of, and perhaps even as much as 100, GHz·km.

24. LIGHT SOURCES AND DETECTORS. This paragraph discusses the characteri~tics of optical sources and detectors, and the rationale for selecting certain devices over others.

a. Light Sources.

(1) Light-Emitting Diodes vs. Laser Diodes. Although it is possible to . transmit a significantly greater bandwidth over a much longer distance using a laser

diode device, light-emitting diodes (LEDs) are preferred and are specified in the applicable FAA equipment. Specifically, LEDs provide:

(a) the probability of a significantly longer device life expectancy,

(b) simplified cooling methods,

(c) sufficiently low optical power so as to obviate concern for eye safety,

(d) simple circuit operation and design,

(e) significantly lower acquisition cost, and

(f) more than adequate capability for the intended application.

b. LED-Based Communication Links. Optical characteristics critical to LEDbased communication link design are: (1) power coupled into a multimode 50/125

fiber, (2) operating wavelength, (3) spectral width (full width at one-half maximum power), (4) risetime and falltime, and (5) source aging. These characteristics are discussed in the following paragraphs.

(1) Power Coupling. Output power from surface-emitting LEDs into a solid hemisphere can be two to three milliwatts. However, the power coupled into an optical fiber pigtail will be less because of the narrow acceptance cone of the optical fiber (determined by its numerical aperture (NA)) and the core diameter. The essential characteristics when considering an LED-pigtail assembly are the

13

8/14/89 6650.8

output power from the pigtail, the core/cladding dimensions and the NA. The typical coupling loss is 14 dB from a LED to a fiber pigtail. Thus if the total output from the LED is 2.5 mW and the NA is assumed to be 0.20, the power coupled into the fiber pigtail and available from the output end is only 0.1 mW (100 microwatts), or -10

dBm (decibels relative to 1 mW).

(2) Wavelength and Spectral Width. The operating wavelength of the LED is selected to coincide with the wavelength-attenuation characteristics specified for the fiber. Spectral widths for l300-nm LEDs are typically 80 to 100 nanometers, and for 850-nm LEDs are typically 50 nanometers, or less.

(3) Risetime and Falltime. Risetime and falltime of the LED and the detector must be considered so that the required systems data rate is not arbitrarily limited by these values.

(4) Source Aging. LEDs degrade slowly with use. The power output for a given input current gradually decreases, and the LED eventually fails. Failure of the LED is defined as a reduction to one-half of the value of the original power output for a given drive current. Therefore, system design dictates that the loop power loss budget be calculated on the assumption that the power output of the source is 3 dB less than its actual initial value.

c. Detectors. Pin diodes are preferred over avalanche photodiodes (APD) for receiver designs despite the 6dB or more disadvantage in gain for reasons similar to those cited for selecting LEDs over laser devices.

25. OPTICAL COLLECTION FACTOR. As mentioned earlier, core diameter is one determinant of how much optical power can be coupled to a fiber. Obviously, the larger the core, the more surface area at the interface that is exposed to light. A change in core from 50 ~m to 100 ~m represents an increase of four times in the

amount of light transmitted. The other measure of a fiber's ability to collect optical power is the numerical aperture (NA).

a. Numerical Aperture. NA is a measure of the fiber's ability to accept light rays that are not parallel to the fiber axis, and transmit them down the core such as shown in figure 2-3. A large difference between the refractive indices of the core and cladding means a larger NA. For equal core sizes, a fiber with a larger NA will accept more light. A power increase by about a factor of two is achieved by going from an NA of 0.20 to one of 0.29.

b. Optical Source/Emitter. Optical source/emitter packaging is designed to couple light into a fiber according to core size. Using a light source not designed for a particular fiber's core size will cause less than optimum light coupling for the system. The effects of core size and numerical aperture have been combined into an optical coupling factor normalized for (referenced to) 100/140 in table 2-1.

Chap 2 Par 24 Page 7

14

6650. 8 8/14/89

FIGURE 2-3. A FIBER'S ACCEPTANCE CONE HALF-ANGLE

RAY OUTSIDE ACCEPTANCE CONE

graded-index fiber

n, maximum refraction index of core

n2 index of refraction of cladding

TABLE 2-1. OPTICAL PERFORMANCE OF TYPICAL GRADED-INDEX FIBERS

Core Cladding Numerical Optical dia dia dia II Aperture Coupling (/.Lm) (/.Lm) (/.Lm) II Factor (dB)

!!

II 50 125 250 II 0.20 -9.5

II 62.5 125 250 II 0.29 -4.3

II 85 125 250 II 0.26 -2.6

II 100 140 250 II 0.30 0 II

26. SYSTEM DESIGN. When selecting components for a fiber optic system, there are two optical fiber factors that affect transmission performance: bandwidth and transmission loss. Transmitter and receiver design combine with the characteristics of the fiber to establish performance limits of the system.

a. Transmission Loss. In addition to changes in the optical pulse shape which result in frequency or bandwidth limitations, there are also reductions in the level of optical power that must be considered. The more significant causes of optical attenuation in optical fiber systems are: optical fiber loss, macrobending losses, connector loss, splice loss and coupling loss. Some of these losses are shown in figure 2-4, and described in greater detail in the following subparagraphs.

15

8/14/89 6650. 8

FIGURE 2-4. SOURCES OF TRANSMISSION LOSS IN AN OPTICAL LINK

FIBER FIBER (FIBER ATTENUATION) (FIBER ATTENUATION)

~TR_A_N __ SM __ ITT __ E_R~~------~J--------~~~ … J … ~~_R_E_C_E_IV_E_R __ ~

\ \ / CONNECTOR CONNECTOR CONNECTOR (INTERFACE LOSS) (INTERFACE LOSS) (INTERFACE LOSS)

(1) Optical Fiber Loss. Light is subject to transmission losses associated with a propagation medium.

(a) Propagation Loss. Propagation losses occur in the fiber due to absorption and scattering. These occur over distance, and the amount of loss depends upon the specific fiber, its size, purity "and the amount and type of dopant used to produce the refraction indices. Attenuation coefficient or the per unit distance amount of optical power loss due to absorption and scattering of optical radiation at a specified wavelength is expressed in decibels per kilometer (dB/km). Since attenuation is an accepted synonym for the fiber optic expression, attenuation coefficient, and since the term is extensively understood in the more familiar radio frequency and microwave transmission applications, it will be used herein as well to avoid unnecessary confusion.

(b) Optimum Wavelengths. Fibers are optimized for operation at certain wavelengths. For example, a loss of less than ldB/km is attainable in 50/125 ~m multimode fiber operating at 1300 nm, and less than 3.5 dB/km is attainable for the same fiber operating at 850 nm. Two wavelength regions, 850-nm or l300-nm, are the areas most often specified for multimode fiber optic transmission because transmitters and receivers operating at these wavelengths are commonly available. Optical fibers have also been optimized at the l550-nm region for single mode transmission.

(2) Microbending Loss. Without support, an optical fiber is subject to losses of optical power caused by microbending. Microbends are minute fiber deviations caused by lateral forces which cause optical power loss from the core. Cables are designed to minimize microbending losses.

(3) Macrobending Loss. Macrobends are relatively large bends in fibers such as those found in splice trays, splice enclosures, and in optical patch cords. For the fibers specified by FAA-E-276la, excess loss will occur when a bend radius is less than 1.5 inches. Particular attention is required at the time of installation and during subsequent maintenance procedures.

Chap 2 Par 26 Page 9

16

6650. 8 8/14/89

(4) Connector Loss. Connector loss is a function of the physical interface of one fiber core to another fiber core. Some of the loss conditions include axial offset, angular, tilt and rotation of the tilt misalignment, as well as end separation of the surfaces. Other loss conditions result from "matching" fibers having different physical characteristics, or the rotational misalignment of cores which are not perfectly circular or concentric with respect to the cladding, or numerical apertures. Some of these loss conditions are shown on figure 2-5. Scratches and/or dirt contamination of the connector surfaces can severely reduce system performance, but most often, the connector loss is due to misalignment or end separation. Depending upon connector type, different fiber optic terminating techniques are used:

(a) Epoxy and Polish. The fiber is epoxied in place in an alignment sleeve, then polished at the endface.

(b) Optical and Mechanical. Both lenses and rigid alignment tubes may be used. In addition, index matching mediums may be employed. The optical power loss of a connector-to-connector interface typically runs between 0.5 and 1.5dB, depending upon the style of the connector and the quality of the preparation.

(5) Splice Loss. Two fibers may be joined in a permanent fashion by welding, fusion, chemical bonding, or mechanical joining. A splice loss that is introduced to the system may be 0.10 dB or less. Various connector and splice loss conditions are shown in figure 2-5. For simplicity, these illustrations are for ray paths ina step-index fiber. The effects of the various defects on the paths in a graded-index fiber are similar. In all illustrations, the direction of transmission is from left to right. Some loss mechanisms are affected by the direction of transmission; others are not.

(a) Fresnel Reflection is caused by the refractive index mismatch between the fiber endface and the surrounding air. This is analogous to the reflection of an electrical signal at the end of an unterminated electrical transmission line. For an ordinary glass fiber, it is approximately 0.18 dB. Where there are two reflective surfaces (e.g., at a pair of mated connectors), the loss will be approximately 0.36 dB. In mated connectors, Fresnel reflection may be reduced by the application of an index-matching gel. It is not necessary for systems designed with adequate margin, and particularly not advisable for field applications where the potential for contamination exists during routine maintenance procedures. In mechanical splices using adhesives to secure the fibers, the refractive index of the adhesive approximates that of the fibers, thus reducing the amount of reflection.

(b) Areal Mismatch Losses. Areal mismatch losses are a result of the receLvLng. fiber not fully nor effectively capturing the light rays emanating from the transmitting fiber and generally include lateral misalignment, core misalignment, and core cladding offset in which a loss may be minimized by rotating one fiber with respect to the other. Still another loss is through cladding diameter variation which in most types of splices and in connectors, the alignment of the fiber relies on the outside diameter of the fiber. If, because of manufacturing tolerances, the outside diameter of one fiber is greater than the other, a corresponding mismatch will exist.

17

8/14/89 6650. 8

FIGURE 2-5. TYPICAL FIBER OPTIC CABLE LOSS CONDITIONS

I stll-----~

Fresnel Reflection

Area Loss due to Lateral

Misalignment

Area Loss due to Core

Size Mismatch

d) Area Loss due to Core-Cladding Offset

Area Loss due to Cladding

Diameter Variation

Gap Loss

Poor Endface Surface Preparation

Fiber Endfaces Not Perpendicular

Mating Fibers Angled

Numerical Aperture Mismatch

i … I ~~

Perturbation of Fiber Geometry

18

6650. 8 8/14/89

(c) Gap Loss. A gap between the fibers results in some of the light rays emanating from the transmitting fiber diverging beyond the cone of the receiving fiber.

(d) Poor Endface Surface Preparation. If there is poor endface preparation: a fractured break instead of a clean, uniformly flat, perpendicular cleavage, or large deep scratch(es) instead of a good polished endface, then light will be scattered at the joint and subsequently dissipated.

(e) Fiber Endfaces Not Perpendicular. If one or both fiber ends are not perpendicular, then there will be losses attributable to a combination of factors, some intuitively obvious from "ray" diagrams. Lack of fiber end perpendicularity is especially harmful in joining single-mode fibers, where ray diagrams do not fully describe the problems.

(f) Mating Fibers Angled. all of the light rays emanating from the acceptance cone of the receiving fiber.

If connecting fibers axes are angled, not transmitting fiber will be captured by the

(g) Numerical Aperture Mismatch. If the numerical aperture of the transmitting fiber is greater than that of the receiving fiber, then even if there are no mechanical imperfections and the fibers are in perfect contact, there will be a power loss due to the fact that the receiving fiber cannot support the higher order modes of propagation. In terms of a ray analysis, not all of the rays of the transmitting fiber will be captured by the acceptance cone of the receiving fiber.

(h) Perturbation of Fiber Geometry. When two fibers are joined by fusion, there will be some disturbance to the waveguide geometry (core-cladding boundary) caused by the fusion process, creating a loss at the splice.

(6) Coupling Loss. Loss between the fiber and the signal source is a function of both the device and the cross-sectional area of the fiber core. Although LEDs emit light in a broader radiation pattern than laser diodes, LEDs, nonetheless, couple sufficient light into a 50 ~m, or greater, fiber core. Lasers are significantly more effective than LEDs for coupling light into single-mode fiber. There is no notable coupling loss between the fiber and detector when the physical interface is per industry standards.

(7) Receiver Sensitivity. Receivers are specified in terms of the amount of optical power required to achieve a given signal-to-noise ratio (SNR) , or in the case of digital signals, bit error rate (BER).

b. Bandwidth - There are four independent components in the expression to calculate system bandwidth; however, only the parameters which are attributable to characteristics of the fiber will be discussed. They are as follows:

(1) Source risetime and transmitter electronics risetime combine for the optical transmitter risetime, Tt .

(2) Detector risetime and receiver electronics risetime combine for the receiver risetime, Tr .

19

8/14/89 6650.8

(3) Intermodal delay is a characteristic associated with multimode fiber. It is a measure of the difference in arrival times at the detector of modes which have been emitted by a source simultaneously, but which are differentially propagated wi~hin a fiber.

(4) Chromatic dispersion is a component dependent upon the wavelength and the spectral width of the source.

(a) Intermodal Pulse Broadening. As discussed earlier, a mode is one of many possible solutions to the wave equation. Consider for simplicity, the ray optics example of a step-index fiber where rays of light are simultaneously incident within the acceptance angle of a longitudinal cross-section of fiber. The figure shows that ray "a" having a shorter distance to travel than ray "b", will arrive at the far end before ray "b" arrives. In one extreme, a ray "c" which has normal incidence travels in a straight line parallel to, or coincident with the

axis, and at the other extreme, the ray "b" which has an incidence angle just within the acceptance angle travels a path, which for the angle of incidence, is the longest. The cumulative difference (intermodal delay) or amount of time that ray "b" is delayed in arriving at the detector is directly proportional to the length of the fiber. Grading the index of refraction reduces the differences in propagation time extremes.

~a:: ~--- =1: .. c _ ~_ _ -- b'" -..- a - … ".'" …

The effect of grading the index is that light propagating through a medium having a decreasingly smaller index of refraction does so at an increasing rate of speed. The longer path lengths associated with rays captured at the extremes of the acceptance cones are compensated for by light which is propagating at a greater rate of speed. There is only one wavelength for which a particular fiber formulation can have optimum bandwidth. The formulation of the graded-index fiber specified in FAA- E-2761a is such that the wavelength of the optimum bandwidth is approximately 1100 nm; resulting in a bandwidth of 400 MHz-km at 850 nm and a bandwidth of 800 MHz-km

at 1300 nm, or

Ti (850 nm) ~ 0.8 ns/km, and

Ti (1300 nm) ~ 0.4 ns/km.

Chap 2 Par 26 Page 13

20

(b) Chromatic Dispersion. Chromatic dispersion is a parameter, the per unit value of which is dependent upon the wavelength of the transmitted light and the spectral width of the source. Silica based fiber is commonly formulated such that it exhibits "zero" dispersion somewhere within the range of 1290-1310 nm. At 850 nm, however, the dispersion is in the order of 110 picoseconds per nm of FWHM2 spectral width per kilometer. The contribution of the spectral bandwidth, Td, is calculated by mUltiplying the FWHM spectral width by 110 picoseconds and the distance in kilometers.

(c) System Bandwidth Calculation. System bandwidth is calculated as follows, where Bw is the -3dB bandwidth.

Bw ~ 0.35/1.1 j (T/ + T/ + Tj 2 + Ti

where:

Tt = Optical transmitter risetime (in ns),

Tr = Optical receiver risetime (in ns),

Tj = Intermoda1 delay per kilometer times link distance (relates to the

"spread" in modal group velocities).

Td = Chromatic dispersion per kilometer times link distance (relates

to spectral width especially at 850 nm; not particularly of consequence at 1300 nm).

NOTE

Since detectors are square-law devices, the 3dB optical bandwidth transforms to a 6dB electronic bandwidth.

It is important to note that an 850-nm LED having a relatively narrow spectral bandwidth of 35 nm FWHM will be a noticeably limiting factor of system bandwidth. Fortunately 1300-nm LEDs, although at the time of this writing more costly, will transfer the limitation in system bandwidth to the intermoda1 bandwidth of the fiber which for the fiber specified by FAA-E-2761A is more than adequate for FAA needs at

a respectable 800 MHz-km. The 850-nm devices will continue to be used for relatively short links in which bandwidth is not of concern. The cost differential between 850-nm and 1300-nm devices will continue to diminish - ultimately, it will

approach a value which will preclude the specification of 850-nm devices.

27. CABLING DESIGN CONSIDERATIONS. Considerations of tensile strength, ruggedness, durability, flexibility, size, resistance to the environment, flammability, temperature range and appearance are equally important in cabling optical fiber as well as electronic cable. However, fiber is considerably more fragile physically than copper, and therefore, packaging concepts for the two materials are different. The following paragraphs discuss the physical capabilities of fiber optic cables and some means of protecting fiber optic cable installations.

2

Data sheets normally provide the Full Width Half Maximum (FWHM) value.

21

8/14(89 6650. 8

a. Fiber Protection. The optical fiber is a very small waveguide. In an environment free from stress or external forces, this waveguide transmits light with minimum loss, or attenuation. However, an unsupported fiber is subject to a loss of optical power caused by microbending as discussed in paragraph 26. To handle this problem, two first-level means for protection of fiber have been developed; loose buffer, and tight buffer. These are shown in figure 2-6.

FIGURE 2-6. EXAMPLES OF LOOSE AND TIGHT BUFFER CONSTRUCTION

LOOSE BUFFER TIGHT BUFFER

OPTICAL

FIBER

BUFFER LAYERS APPLIED DIRECTLY OVER FIBER

(1) Loose Buffer. In loose buffer construction, the fiber is contained in a plastic tube that has an inner diameter considerably larger than the fiber itself. The loose tube isolates the fiber from the exterior mechanical forces acting on the cable. By controlling the amount of fiber inside the tube, the amount of allowable temperature variation can be increased and, therefore, the degree of attenuation over a temperature range is minimized.

(2) Tight Buffer. The other fiber packaging te~hnique, tight buffer, uses a direct extrusion of plastic over the basic fiber coating. Tight buffer construction serves to protect the fiber from crushing and impact loads, and to a certain degree, reduces the microbending losses that would otherwise be induced during cabling. Tight buffer design, however, provides only minimal isolation for the fiber from the stresses of temperature variations. While relatively more flexible than loose buffer, if the tight buffer is deployed with sharp bends or twists, optical losses are likely to exceed nominal specifications due to macrobending.

(3) Both Buffer Constructions. Both loose buffer and tight buffer constructions have inherent advantages. The loose buffer tube offers lower cable attenuation from microbending for any given fiber, plus a high level of isolation from external forces. Under continuous mechanical stress, the loose tube permits more stable transmission characteristics. The tight buffer construction permits smaller, lighter-weight designs for similar fiber configuration, and generally yields a more flexible, crush resistant cable. Advantages of both tight and loose buffers are summarized in table 2-2.

Chap 2 Par 27 Page 15

22

6650.8 8/14/89

b. Physical Choices. Decisions must be made about cabling the fiber to meet installation strength requirements and protection from the environment. For installation of a cable, mechanical properties such as tensile strength, impact resistance, flexing and bending are important. Environmental requirements concern the resistance to moisture, chemicals, and other types of atmospheric or in-ground conditions.

TABLE 2-2. LOOSE AND TIGHT BUFFER TRADEOFFS

Cable Parameter

Bend radius

Diameter

Tensile st~ength,

installation

Impact resistance

Crush resistance

Attenuation change

at low temperatures

c. Mechanical Protection.

Cable Loose Tube

Larger

Larger

Higher

Lower

Lower

Lower

Structure

I Tight Buffer

I Smaller

Smaller

Lower

Higher

Higher

Higher

(1) Normal cable loads sustained during installation may ultimately place the fiber in a tensile-stress state. The levels of stress may cause microbending losses which result in an attenuation increase and possible fatigue effects. To buffer the fiber from stress loads in short-term installation and long-term application, various internal strength members are added to the optical cable structure. Such strength members provide the tensile load properties similar to electronic cables, and keep the fibers free from stress by minimizing elongation and contraction. In some cases, they also act as temperature stabilization elements. Table 2-3 indicates the relative performance considerations for each of the common strength members. Optical fiber stretches very little before it breaks, so the strength members must have low elongation at the expected tensile loads. Aerial cable installation, for example, must be protected from excessive tensile loading from wind and ice. Impact resistance, flexing and bending are other mechanical factors affecting choice of strength members.

(2) Cable strength members which are typically used in fiber optic cable include Kevlar™ aramid yarn, fiberglass epoxy rods, and steel wire. On an equaJ weight basis, Kevlar is considerably stronger than steel. Kevlar and fiberglass epoxy rods are often the choice when all-dielectric construction is required. Steel is sometimes used where extremely cold temperature performance is required, since it can offer better temperature stability, however, it does conduct electricity.

23

8/14/89 6650. 8

TABLE 2-3. STRENGTH MEMBER COMPARISON OF DIFFERENT MATERIALS

I I 'Elongation 'Weight Material Break Diameter , break , Lb. (lb. ) (in. ) , (%) ,(K ft) , , I Fiberglass epoxy rod 480 0.045 , 3.5 , 1.4 , , Steel 480 0.062 , 0.7 , 7.5 , , Kevlar aramid yarn 944 0.093 , 2.4 , 1.8 I I

d. Environmental Protection. As with conventional wire cables, the outermost jacket ultimately protects the innards from the external environment. In addition, the various plastics used as jackets exhibit different characteristics when exposed to the physical and chemical effects of the operating environment. Typical tradeoff characteristics of various jacketing materials are listed in table 2-4. Fiber optic cables are available with numerous combinations of jacket materials suitable for installation in underground ducts, aerial suspension, direct earth burial, plenum or cable raceways.

e. Recommended Cable. Specification FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable provides a selection of cables for the various environmental conditions.

28. FIBER OPTIC CABLE INSTALLATIONS.

a. Typical Power and Fiber Optic Cable Installation at Airports. Power cables in the loop are generally routed underground between loads. Both power cables and fiber optic cables are routed: in the same duct bank for short runs or in areas around buildings, or in a direct earth burial (DEB) trench for long, unobstructed runs. Although it is acceptable to install cable in a DEB trench for long unobstructed runs, it is generally desirable to run power cables and fiber optic cables in ducts.

(1) Installation of Fiber Optic and Power Cables in Same Trench. To minimize installation costs, totally dielectric fiber optic cable may be run

together with power cables in the same duct. Wherever practical, the fiber optic cable may be placed in the same duct with barriers or separation in accordance with NEC provisions. Generally, fiber optic runs are free of splices between terminals. Optical fiber terminations and conversions to electrical signals will be made inside

the protection of buildings.

(2) Manholes. Although the power and totally dielectric fiber optic cables may be run together, it is recommended that they have separate manholes to promote

safety during maintenance. It also makes maintenance easier.

(3) Entering Buildings. Armored fiber optic cable should be terminated and grounded in manholes or handholes at least ten feet from the building. Cable entry into a building shall be via a ferrous (rigid) conduit. After being grounded, the armor shall extend a minimum of five feet into the conduit and the entrance to the conduit appropriately sealed. Fiber optic duplex cable is used from the point of demarcation upon entry to the building. Diversity of the cable paths within the

Chap 2 Par 27 Page 17

24

6650.8 8/14/89

facility including points of entry into a facility should be considered for critical applications. Interior fiber optic cable should be installed in a manner which ensures that the cable is protected from being curled, coiled or twisted to the point that the minimum allowable bend radius limit has been violated. Installing it in a 1/2" PVC conduit is one approach; however, other less conservative techniques will be adequate. In general, the maximum vertical rise without intermediate support is 250 feet. Supports should be of a type that distribute the load and prevent bend radius problems.

TABLE 2-4. TRADEOFFS OF VARIOUS JACKETING MATERIALS

I I I I Low- High-

IpOlY

IPOlY density Cellular density Poly vinyl poly poly poly Attribute Ipropylene urethane Nylon Teflon Ichloride ethylene ethylene ethylene :

I Resistance to abrasion I F-G 0 E E F-G F-G E I I Electrical properties I E P P E I F-G E E E

Flammability resistance ~ P F P 0 I E P P P

II I

~ I

Resistance to nuclear radiation i G F-G P I G G G G

II I Corrosion resistance to water ~ E P-G P-F E I E E E E

Corrosion resistance to acid ~ E P-F E I G-E G-E G-E G-E

~ I

~ I

Resistance to aliphatic hydrocarbons such as i P-F G G E I P P-F P-F P-F kerosene, gasoline, etc. ~ I I I Resistance to aromatic hydrocarbons such as I

P-F P G E

I

P-f P P P toluel, benzol, etc.

~ I Resistance to halogenated hydrocarbons such ~ P P G E I P-F P P P as degreasing agents

~ I

II I I I Resistance to alcohol I

E P P E

I

G-E E E E

Resistance to oxidation I E E E 0 I E E E E I I Resistance to heat I

E G E 0 I

F G G G-E

I I I I Resistance to oil immersion I

E E 0 I

F G G G-E

Resistance to weathering, ultraviolet I E G E 0 I G-E E E E radiation from solar exposure I I I

I Flexibility at low temperatures I P G G 0 P-G E E E ! I Resistance to ozone exposure I E E E E I E E E E I I

KEY: P = Poor, F = Fair, G = Good, E = Excellent, o = Outstanding

Chap 2 Page 18 Par 28

25

8/14/89 6650.8

(4) Inner ducting. Inner ducts should be used to avoid subjecting the fiber optic cable to the stresses associated with pulling the power cable, and to facilitate future cable installations.

(5) Bending Radius. The minimum bending radius of the fiber optic cable must not be less than the radius specified in FAA-E-2761a, during any phase of

installation or operation.

(6) Labeling. The fiber optic communications cable and the power cables should be clearly and continuously labeled at all accessible points and in the manholes as specified in the appropriate local, state and federal electrical and

safety codes. This minimizes the possibility that maintenance personnel might confuse the power cable for the fiber optic communications cable or vice versa.

b. Safety Concerns. Personnel safety is of paramount importance at all times. The major safety concern in placing fiber optic cables in close proximity to power cables is preventing the transmission of power cable fault current or other electrical current by the armor of the fiber optic cable. Such currents would endanger personnel working on the cables. Totally dielectric fiber optic cables inherently prevent the transmission of fault currents because of the absence of conductive paths. Therefore, totally dielectric fiber optic communication cables may be placed with power cables without compromising safety.

29.-39. RESERVED.

Chap 2 Par 28 Page 19 (and 20)

27

8/14/89 6650.8

CHAPTER 3. FIBER OPTIC CABLE LOOP SYSTEMS

SECTION 1. BASIC REQUIREMENTS

40. CHARACTERISTICS. Loop systems are transmission systems having closed paths that provide inherent redundancy in the event that any single link is severed. The advantage of a fiber optic loop is that it can be implemented with as few as two fibers by using networking equipment and is in contrast to traditional field cable which normally requires mUltiple pairs per facility. Some of the characteristics are discussed below.

a. Configurations. There are two basic loop configurations to consider: one is when the loop is shared by only two facilities, and the other is when the loop is

shared by three or more facilities.

b. Protocol. A loop that is shared by three or more facilities must have some form of effective protocol to govern which facility is to have access at any given time, and to ensure that the integrity of the data being transmitted is maintained. Possible protocols might be:

(1) Token ring network where the supervisory function moves with the token,

(2) Time-division protocol such as a synchronous, time-division multiplexed network using for example, a digitized voice/data channel bank where all facilities have equal access, or

(3) Fixed master-slave relationship (poll-select) where a slave is addressed and responds according to a predetermined protocol.

c. Construction. A fiber optic loop can be constructed in one of two basic configurations: a ring bus where there is a transmit loop and a receive loop, and within which, passive optical signal splitter devices are configured to allow bidirectional transmission using only two fibers (figure 3-1); or counter-rotating

rings where the signal is retransmitted at each facility except at the master/supervisor (see figure 3-2).

d. System Constraints. The following describes the constraints of the ring bus structure and counter-rotating ring structure.

(1) Ring Bus. The ring bus structure is severely limited by a reduction in power at each node along the loop. This creates a major drawback which is inherent when the loop has been optimized for transmitting in both directions.

(2) Counter-Rotating Ring. The counter-rotating ring structure is not constrained in any obvious way by the number of facilities serviced by the loop as would be the case for a passively-coupled ring bus structure where a reduction in

power occurs at every facility. However, the counter-rotating ring is limited by the amount of pulse broadening which is introduced as a result of a pulse being retransmitted repeatedly. The extent of the limitation is a function of the data rate and the effective slew rates of elements comprising the signal path.

Chap 2 Par 29 Page 21

28

6650. 8 8/14/89

FIGURE 3-1. RING BUS CONFIGURATION

RECEIVE RECEIVE

TRANSMIT TRANSMIT

ATCT RT

GS, VASI, RVR MALSR

LEGEND

PLCM MASTER PROGRAMMABLE CONTROLLER

PLCS SLAVE PROGRAMMABLE CONTROLLER

D DELAY R fiBER OPTIC RECEIVER T fiBER OPTIC TRANSMITTER S OPTICAL SPLITTER

8/14/89 6650.8

29

FIGURE 3-2. TWO COUNTER-ROTATING RINGS

ATCT RT

GS, VASI, RVR MALSR

LEGEND

PLCM MASTER PROGRAMMABLE CONTROLLER

PLCS SLAVE PROGRAMMABLE CONTROLLER

D DELAY R FIBER OPTIC RECEIVER T FIBER OPTIC TRANSMITTER

Chap 3 Par 40 Page 23

6650.8 8/14/89

For example, at a 19.2 Kbps Non-Return-to-Zero (NRZ) data rate, a pulse width increase of as little as 2 to 3 microseconds per transmission, in conjunction with pulse jitter, can affect the bit error rate (BER) after as few as 6 or 7 repetitions. Networks including more than 6 or 7 facilities would need, therefore, to either periodically recondition the signal or more closely control both the amount of pulse broadening, and jitter.

30

e. Recommended Protocols. The two recommended protocols for multiple 'facility loops (both being implemented using a counter-rotating ring structure) are

a mas teL with multiple slaves configuration, and time-division multiplexing. Not being burdened with the operations associated with sharing of the supervisory

functions, both approaches offer acceptable performance in a real time environment.

41. MASTER-SLAVE RELATIONSHIP. Facilities in the system (ATCT, RT, ASR, etc.) are distributed about the airport at locations governed by their individual installation requirements. In a master-slave relationship each facility on the loop receives all the data transmitted on the loop, but accepts and reacts only to the information addressed to it. It is implicit in the concept that intelligent devices such as programmable logic controllers (PLC) are placed at each facility in the network for which a master-slave relationship is in effect. The principle advantages of this approach are that a loop can be designed and implemented using conventional PLCs, fiber optic modems/transceivers (standard interfaces such as EIA-232 and EIA-422), and a simple interfacing unit. The resulting configuration is modular at the facility level.

a. System Operation. This paragraph along with figure 3-3 describes the operation of a master-slave configuration using counter-rotating rings. In a counter-rotating ring configuration, two loops are used. One ring transmits in a clockwise (cw) direction, while the other transmits in a counterclockwise (ccw) direction. This provides a fully redundant system that is unaffected by a single failure in either loop.

loop. to the

(1) The ATCT (master) transmits interrogation or command signa+s into the These signals are received by a facility (slave), regenerated and transmitted next facility in the loop.

(2) The signals typically consist of a facility address code followed by the message (command, control or status) for that facility (figure 3-2). A facility's response to an ATCT interrogation takes the form of an immediate message into the loop. When the ATCT has received a response it repeats the sequence until all facilities have been interrogated and have responded.

(3) If a facility fails to respond within a prescribed time and after a predetermined number of polls, diagnostic operations are initiated at the ATCT to determine the failure mode. When a message becomes garbled during transmission, a request to retransmit will be generated.

(4) The ATCT receiving equipment is configured to prevent retransmission of signals.

(5) Both the cw and the ccw transceivers receive signals from their respective directions as well as retransmit them. Although the two signals are identical, they are not synchronous at any given facility because the lengths of the transmission paths are different. Therefore, some accommodation is necessary, using

31

8/14/89 6650.8

FIGURE 3-3. DIALOG BETWEEN ATCT AND ANOTHER FACILITY

ATCTsends

messages to a facility

Messages arrives at facility

Interrogate:

Arrival time at Recognized and Responded to facility

Response: facility ATCT Address Code responds and sends message toATCT

Response arrives at ATCT

FaciUty Address Code Message Code

ATCT Transmit

Bus Time

ATCT Recieve Bus Time

32

one of two methods. One is to correct for the difference in arrival times. The other method is to preferentially accept either of the two signals based on a criterion such as signal quality or some other predetermined preference, or a combination of the two methods.

(a) A digital signal is transmitted at the ATCT bidirectionally to a facility. The signal arriving first is delayed and logically OR'ed with the later of the two signals using a module defined by FAA-E-2809, Airport Facility Fiber Optic Interface. The response from the facility to the ATCT is also transmitted bidirectionally, however, the signal which would have otherwise arrived at the ATCT

first is delayed using the same module as described above. At the ATCT, both signals arrive, within tolerance of the delay logic, at the same time and are logically OR'ed. This approach provides the distinct advantage of uninterrupted and undisturbed communications in the event of a cable break or a single component

failure in either ring. An exclusive-OR logic circuit is incorporated for fault detection.

(b) The simplest implementation of the second approach is to sense for the presence of a carrier, and to switch to standby when the carrier of the primary is no longer detected. The carrier simply meant to imply that there is a measurable signal for both the ones and zeroes such as in a Manchester "M" encoding

scheme (see figure 3-4). Although this approach almost certainly results in a loss of communications for a one-bit interval, there are many applications for which it would be acceptable. It also offers the advantage of a reduced number of components with an attendant increase in reliability. In figure 3-4, a "one" is discriminated by a "zero" volt to logic level transition within a plus/minus tolerance of the midpoint of the bit cell; a zero is the complement.

BINARY CODE

IN BIT CElL CONFIGURATION

"M"CODE

FIGURE 3-4. MANCHESTER "M" ENCODING SCHEME

o o o o

I I I

vo~lj~j H H d b H i

OV ~ … ~ … ~ __ ~ __ -L-L-L __ ~~~ __ ~ __ ~ __

33

8/14/89 6650. 8

42. TIME-DIVISION MULTIPLEXING. Each facility in the loop receives data on the loop, but accepts and reacts only to the data in the serial stream during the assigned time cells for a specific facility. The design concept is modular at the channel level, clearly a potential advantage when there are enough data/voice channels to be transmitted per facility to warrant this approach. Associated with the performance characteristics and the number of channels, which can be accommodated by a T-carrier with voice/data channel bank, is a corresponding size and cost factor which dictates that the deployment of such be evaluated on a site-by-site basis. The same concept, in reduced scale, uses synchronous/ asynchronous multiplexed transceivers with drop and insert capability as described in FAA-E-2820, Fiber Optic, Multiplexing, Drop and Insert Modem which in general, although having less channel capacity and reduced performance characteristics, also has significantly lower cost.

a. System Operation. The following describes the operation of a time-division multiplexer.

(1) A synchronous bit stream is transmitted into the loop. For drop and insert, the signal is received, and retransmitted at each facility.

(2) The bit stream provides transmit and receive time cells for every channel module, even if it is not in use.

b. Channel Banks. Many of the voice channel modules used by the telecQmmunications industry include an "E" (ear) lead and an "M" (mouth) lead which is used to transmit signaling information such as IDLE/BUSY. This capability can be used to pass transmitter keying information to the remote transmitter sites: Neither the T-carrier voice/data channel bank, nor the multiplexed synchronous

transceiver with drop and insert capability provide the means to request the retransmission of data if the message is garbled during transmission. This approach, if it is a requirement, relies on the source and destination devices monitoring the integrity of transmitted messages and requesting retransmission when needed.

SECTION 2. DETAILED REQUIREMENTS

43. SYSTEM DESIGN CONSIDERATIONS AND PROCEDURES. This paragraph discusses the characteristics of the air traffic control communications, control and indication signals found at airport facilities, how they are classified, catalogued and partitioned for transmission over fiber optic cable loop systems. Each of the equipment specifications referenced herein addresses' reliability/ availability and maintainability; the requirements were defined in the context of NAS SS 1000 . Without any known exceptions this is achieved by implementing the system with some degree of redundancy. Included are discussions of transmission noise, losses and delays.

a. Air Traffic Control Signals. This paragraph discusses the characteristics of air traffic control signals to be handled by fiber optic cable loop systems.

Chap 3 Par 42 Page 27

34

6650.8 8/14/89

(1) Airport Facilities. Airports typically have the following types of facilities generating or receiving air traffic control signals:

(a) ALS Approach Lighting System

(b) ALSF Approach Lighting System with Fla.shers

(c) ASR Airport Surveillance Radar

(d) ATCBI Air Traffic Control Beacon Indicator

(d) ATCT Air Traffic Control Tower

(e) DME Distance Measuring Equipment

(f) GS Glide Slope

(g) 1M Inner Marker

(h) LOC Localizer

(i) MALSR Medium-Intensity Approach Lighting System with Runway Alignment Indicator Lights

(j) MLS Microwave Landing System

(k) MM Middle Marker

(1) MODE S Mode S

(m) OM Outer Marker

(n) RTR Remote Transmitter/Receiver

(0) RVR Runway Visual Range

(p) VOR VHF Omnidirectional Range

(2) Signal Bandwidth. The signals communicated between the ATCT and the other facilities listed above are classified as low, audio or video frequency. In preparation of the airport communications cable loop design, list all current and proposed facility frequencies as classified in the following paragraphs.

(3) Low-Frequency Signals. Low-frequency signals found at an airport range from direct current (DC) to approximately 70 Hz, and are:

(a) Binary (on/off) for control or status indicators,

(b) Analog for remote meter indicators or DC potentiometer voltage levels

(c) RVR pulses.

Chap 3 Page 28 Par 43

35

8/14/89 6650.8

These signals are transmitted in one of the above forms to and from the ATCT and the other facilities to indicate status, and to provide control information on various relay operations or meter circuits. Since these change slowly, bandwidth requirements and information rates are low. There may be 200 or more low-frequency signals at a activity Level III, IV or V airport.

(4) Audio-Frequency Signals. Audio-frequency (voice band) signals are in the frequency range from 300 to 3400 Hz. These signals have traditionally been transmitted between the ATCT and the RTRs over two wires balanced to ground. There are other voice grade circuits in an airport loop system such as the instrument landing system (ILS) control and readback tones.

(5) Video-Frequency Signals. The video-frequency signals found at an airport range up to 6.7 MHz and consist of analog video and triggers pulses. They are transmitted from the ASR site to the ATCT. The most frequently encountered video-frequency signals are:

(a) Normal video,

(b) Beacon video,

(c) Beacon triggers,

( d) Moving target indicator (MTI) video, and

(e) Normal video triggers.

(6) Signal Types. Generally, the airport signals of interest include, but are not limited to those listed in table 3-1.

b. Cataloging Signals. After classifying signals by frequency, the next step is to catalog all such data with respect to pertinent specifics such as facility location, demarcation box, terminal block number, terminal number, electrical interface parameters, etc.

TABLE 3-1 AIRPORT SIGNAL TYPES

Low Frequency

Readback/status

control

Runway visual

range

Meter circuits

General communi-

cations

Audio Frequency

Air/ground voice

Audio control/

readback tones

Mode Sand ASR-9

modem signals

Video Frequency

Normal video/trigger

Moving target indicator

video

Beacon video/trigger

Azimuth*change

pulse

Azimuth*reference

pulse

* Although the repetition rates of ACP and ARP are low, the

frequency content of the required pulse rise and fall times is high.

36

6650.8 8/14/89

c. System Partitioning. In order to retain a modular approach, especially for facilities which do not have shared-maintenance personnel, the recommended network design is one having four basic functional subsystems, each having an appropriate number of fibers assigned to it. One subsystem is radar signals which include normal video with trigger, beacon video with trigger, moving target indicator video, azimuth reference pulses and azimuth change pulses. A second subsystem radar control and readback. A third subsystem provides for voice signals and a the fourth for general communications. The approach using four subsystems has the added advantage of providing the option of an airport communications network being installed in easily defined increments. In the overall scheme, there will be instances, however, where it is clearly and logically appropriate to integrate the system functionality of each of the functional partitions above, or some combination or subset thereof. All of these subsystems are discussed in greater detail in the following subparagraphs.

(1) Radar Signals. Except for the ASR-9, the recommended equipment for transmitting radar signals is defined by FAA-E-2790, Fiber Optic, Video Airport Surveillance Radar Transmission System. Guidance for implementation is provided within the system configuration section of FAA-E-2790. For the ASR-9, a fiber optic multiplexing transceiver appropriate for that system is defined in FAA-E-2820, Fiber Optic, Multiplexing, Drop and Insert Modem.

(2) Radar Control and Readback. The recommended equipment for multiplexing and demultiplexing the control and readback signals are programmable

logic controllers (PLCs) as specified by FAA-E-2789, Monitor and Control, Programmable Logic Controllers. This equipment provides a high degree of flexibility and the capability for possible role expansion. It includes the integration of functions normally associated with the general communication subsystem as well as some requirements still undefined, such as environmental remote maintenance monitoring. The decision to include such capabilities must be evaluated on a site-by-site basis, and only after careful consideration of possible systemic

impact.

(3) Voice. T-carrier and channel bank equipment are recommended for voice communications. Drop and insert capability should be considered when two or more transmitter or receiver sites are included within the loop or system of loops. The signalling circuits of the channel module can be configured to to effect transmitter keying. An example of a level-shifting technique is shown in figure 3-5. In the near future, voice communications between the ATCT and the RTR will be handled by radio control equipment (RCE). Transmit keying will no longer be +48 vdc, but a digital control signal. The FAA specification describing the channel bank and T-carrier equipment is FAA-E-28l0, T-carrier with Drop and Insert.

(a) Channel Banks. The flexibility of having both main and standby channel banks can be exploited to simplify system design, and reduce system cost. Specifically, the main channels should be transmitted using one system and the standbys should be transmitted using the backup. Partitioning the system in this manner eliminates the need for additional crossover equipment by relying on the FAA's existing manual capability to do so at the ATCT cab and the TRACON.

37

8/14/89 6650.8

(b) Antenna Changeover Signals. Antenna changeover signals can be transmitted using the general communications subsystem; however, there will be instances where this is not feasible. In these situations, there are two options; multiplex the signals onto an EIA-232 compatible line and transmit them using a data module in place of a voice channel, or use the transmitter keying signal to energize

a corresponding latching coaxial antenna changeover switch.

(c) Other Applications. In addition to voice, the channel bank equipment can be used to transmit ASR-9 modem signals as well as the control and readback tones of a localizer or glide slope when they are within reasonable distance of a site with a channel bank. Yet another application for the channel bank is to remote alarm information for the RMMS, provided the equipment is co-

located with a channel bank.

(4) General Communications. Signals in the general communications loop are for:

(a) Monitor and control of a power loop,

(b) Glide slope and localizer control/readback,

(c) Runway visibility data and control,

(d) Runway lighting and control/readback,

(e) Antenna changeover, and

(f) Environmental sensor signals.

The programmable logic controller having an extensive variety of I/O interface modules is a near-ideal solution for integrating a diversity of signals into a common network. The general communications loop can be implemented in one of the possible approaches given below:

(a) Counter-Rotating Asynchronous Rings, one clockwise and the other counterclockwise, using transceivers and a means to multiplex and demultiplex such as a PLC, or

(b) Multiplexed Transceivers/Modems with "drop-and-insert", a synchronous ring structure with asynchronous capability, can also be configured in counter-rotating rings, a more flexible, but more costly means for equal performance which is justified only if requirements for multiple data channels are present. MUltiplexed transceivers/modems with "drop-and-insert" can be an appropriate

solution for networking a number of facilities such as RVRs or remote maintenance monitoring systems (RMMSs) which have similar communications requirements. The RMMSs are mostly EIA-232 synchronous compatible; the "Tasker" or transmissometer

type RVRs, however, are not, and will require interface modules such as those specified in FAA-E-2809, Airport Facility Fiber Optic Interface. Specification FAA-E-2820, Fiber Optic, Multiplexing, Drop and Insert Modem provides information on modules for both requirements.

d. Signal-to-Noise Ratio and Bit Error Rate. The signal-to-noise ratio (SNR) for transmitting analog and digital signals, and the bit error rate (BER) resulting from transmitting digital signals are discussed in the following paragraphs.

Chap 3 Par 43 Page 31

38

6650. 8 8/14/89

(1) Signals Sent in Analog Form. Signals sent in analog form over the fiber usually require a higher SNR than those in digital format. The digitizing process, although requiring greater bandwidth (not a problem in fiber optic

technology), allows the optical signals to be sent as pulses, which require less power while achieving a comparable signal-to-noise-ratio.

(2) Binary Signals. For binary signals representing relay or switch status, an SNR of 17.3 dB is required. For slowly varying analog signals, a band of 2 percent uncertainty at full scale is acceptable. This translates into an SNR of 17 dB.

(3) Pulse Modulated Signals. For pulse-code modulation (PCM) fiber optic carrier systems that multiplex many voice channels, the accepted (BER) standard of the industry is 10-9 . This corresponds to an SNR of 21.5 dB, or an absolute power ratio of 141:1.

(4) Video Signals The SNR of the MTI and normal video signal is set to 4:1 at the sensor site. The SNR must be preserved accurately so that when the signal is received at the tower targets can be extracted from the "noise". In order to ensure that the ability to do this is not significantly degraded by noise introduced during the transmission process, An SNR of at least 35dB is specified for the transmission system. FAA-E-2790 specifies that the condition for normal operation will yield a SNR of at least 45 dB.

e. Losses. The following discusses how optical power losses are determined.

(1) Loss Determination. In a fiber optic loop system, signal losses must be determined in order to insure that sufficient optical power is present at each

receiver to preserve an acceptable SNR (and corresponding BER). All losses must be considered between the transmitter LED at one end of the link, and the receiver photodiode at the other end of the link.

(2) Counter-Rotating Ring Losses. For the counter-rotating ring configuration, because the signal is regenerated at each facility, the consideration of link loss is limited to identifying the longest link in the system, and includes splicing, connectorization, and macrobending losses. When using 850-nm light sources, the attenuation is 3.5 dB per kilometer, and when using 1300-nm light sources, the attenuation is 1.0 dB per kilometer as specified by FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable. To this, splicing losses at

~ O.ldB/splice and connector losses at ~ 1.5 dB/mated connector must be added.

44. CABLE. This paragraph describes the primary and environmental characteristics of fiber optic cable, selection rationale, and maintenance considerations for cable loop systems in general.

a. Primary Characteristics. The opto-electronic characteristics of primary interest in the selection of fiber waveguide are attenuation (in dB/km), bandwidth

(in MHz-km), and Numerical Aperture (NA). NA is defined as the sine of the acceptance cone half angle (a measure of the fiber's ability to accept light rays that are not parallel to the fiber core axis. Attenuation and bandwidth requirements are commonly used to specify cable performance. Refer to specification FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable for more information.

39

8/14/89 6650.8

b. Fiber for FAA Use. The fiber to be used by the FAA for telecommunication purposes (multimode) has a SO/12S-micron core/cladding dimension ratio, with a NA of 0.20 to 0.24. The following attenuation and bandwidth characteristics are given for the dual window wavelengths of 8S0-nm and 1300-nm.

I Wavelength I 850 nm 1300 nm I Attenuation: I < 3.5 dB/km < 1.0 dB/km I Bandwidth: I > 400 MHz-km > 800 MHz-km I

c. Environmental Characteristics. The cable must meet environmental and certain other site-specific requirements such as resistance to the effects of

immersion in jet fuel, (for which a fluoropolymer such as polyvinylidine fluoride or other suitable material, is specified). Specification FAA-E-2761a, Multimode, Multifiber, Fiber Optic Cable provides further guidance in specifying cable type.

d. Other Maintenance Considerations. This paragraph addresses the repair of damage to the fiber optic cable.

(1) Breakage. After a fiber optic cable has been buried, it is possible that it will be crushed or severed accidentally. This is most likely to occur when heavy earth-moving construction equipment is used in the airport area. The fiber optic loop system will be the most susceptible to damage during facility changes or extensions to runways.

(2) Splicing. The general repair procedure is to cut out the damaged section and splice in a replacement section of cable. Each splice introduces power loss at the junction. When semiautomatic fusion splicing apparatus is used on multimode fiber, the loss is typically 0.3 dB or less. It can be reduced to nearly 0.1 dB if the core concentricity, core and cladding diam~ters, grading coefficient, and numerical aperture parameters have been closely controlled as specified in FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable. For quick restoration of service in an emergency, a glass tube mechanical splice is low cost, fast, and provides an optical loss comparable to fusion splicing. Fibers are identified by colored buffer tubes or distinctive coloration in the protective coating.

45. AIRPORT LOOP SYSTEM DESIGN. This paragraph provides suggestions and procedures for acquiring the types of information and allocating resources necessary to develop a detailed airport fiber optic cable loop system design.

a. Airport Information Required. The step-by-step process outlined on figure 3-5 is the best way to determine the detail hardware requirements for any given airport. It should include:

(1) planned facilities to be interlinked,

(2) proposed facilities to be relocated,

(3) proposed or anticipated facilities to be added,

Chap 3 Par 44 Page 33

40

6650.8 8/14/89

(4) types of information to be communicated such as data, voice video and power control,

(5) types and quantity of equipment to be requested.

b. Information Resources. This paragraph identifies those preliminary tasks and requirements to aid in planning the most efficient and effective installation: (1) existing airport layout drawing, (2) current aerial photograph, (3) airport master plan, (4) recent airport modification drawings, (5) visits to each facility to map internal equipment locations, (6) visits to each facility to document equipment and type of signal to be transmitted/ received, (7) discussions with airport manager about foreseeable airport modifications and site specific requirements, and, (8) determine FAA facility modifications and updates.

(1) Airport Layout Drawing. An up-to-date set of airport layout drawings are necessary since they are the best source of information for detailing the loop

layout. Items such as underground pipelines, existing underground duct systems, open water or swamps, solid rock terrain, ground fault areas, and existing communication cables should be indicated. Normally, when required, ducts shall be installed parallel to, or perpendicular to runways or building restriction lines. Cable routings when practicable shall avoid runway/taxiway crossings and other critical areas to minimize the impact upon scheduling of construction and maintenance activities.

(2) Aerial Photographs. Current aerial photographs should be obtained to supplement the airport layout drawings. The photographs should be annotated to identify the locations of facilities, and a vellum positive produced from which blue-line drawings of the overall airport and portions of the airport can be made. Loop layouts and distances can be accurately determined from the blue-line prints.

(3) Airport Master Plan. If a master plan exists and is of recent issue, it can be a good source of information. If it is more than 5 years old, steps should be initiated to update the master plan.

(4) Planned Airport Modifications. As planned airport modifications are part of the selection criteria, it is more than likely that detailed drawings of planned renovations exist. One or two sets should be obtained for planning the fiber optic communications loop.

(5) Facility Mapping. Each facility which is anticipated to be in the loop should be visited to study and sketch to scale the facility and the location of the demarcation box. For multiple-floor facilities, all cable shafts, raceways and access points should be identified and noted. Likewise, false floors and ceilings should be noted.

(6) Facility Equipment and Signal Documentation. The facility review should include a list of the facility equipment by manufacturer, type, and current FAA revision level, where applicable. At each junction box, a list of the signal leads which are entering/exiting the facility, their source/destination, signal

characteristics and a brief description of their function must be prepared.

41

8/14/89 6650. 8

FIGURE 3-5. DETAILED COMMUNICATION LOOP LAYOUT

DETAIL BY FACILITY

(PRESENT AND FUTURE)

I

1

1 1-- LENGTH OF RUNS

1 IN FACILITY

1

1 1-- LOCATIONS WITHIN

1 FACILITY FIRST

1 FLOOR

1

1 1-- NUMBER AND TYPE

1 OF SIGNALS

1

1 TYPE OF CABLE

INFORMATION

GATHERING

-- NUMBER OF FIBER LOOPS

QUANTITY AND TYPE

OF I/O

-- NUMBER AND TYPE OF PLC

NUMBER AND TYPE OF

TRANSMITTERS AND RECEIVERS

OVERALL LOOP LAYOUT

INDIVIDUAL UNINTERRUPTED

INTERFACILITY CABLE LENGTHS

-- OVERALL LOOP LENGTHS

-- DUCT REQUIREMENTS

-- MANHOLE REQUIREMENTS

-- LOOP SIGNAL LOSSES (DB)

PHYSICAL OBSTRUCTIONS

ABOVE AND BELOW GROUND

42

6650. 8 8/14/89

c. Overall Loop Layout. This paragraph discusses the information obtained in paragraph 45.b for the overall loop layout shown in figure 3-5, and applies it to an overall airport communication loop layout such as that shown in figure 3-6. It is important at this point of the loop design process to recognize that in certain instances, it will be a previously installed point-to-point fiber optic link which is the precursor to a loop configuration. The loop is created by providing one or more links to provide closure and a means to multiplex, or demultiplex, signals on

the loop in order to utilize the pre-existing fibers. It is also important to recognize that a loop system may include some point-to-point elements which mayor may not be intended to be the precursors to future loops.

Furthermore, a loop design must consider the consequences of common failure points. Independent multiplexing subsystem (subloops) will reduce the number of common failure points, thereby reducing the risk of catastrophic failures. Redundant multiplexing subsystems are generally warranted when/where concern for critical functions exist.

(1) Facilities to be Incorporated. Identify on the aerial photographs or copies of the airport plan drawing the facilities to be incorporated in the communications loop(s). In addition to the information given in the detailed loop layout (figure 3-5) include and identify the following: (a) relocation sites, (b) new sites, (c) proposed sites, (d) proposed installation dates, (e) proposed commissioning dates, and (f) fly-by test requirements. Note that for facilities requiring fly-by testing, the exact location is indeterminate, and could vary by plus or minus 300 feet. This process is illustrated in figure 3-7 for a hypothetical airport. This airport, modeled after Meadows Field Airport in Bakersfield, California is used throughout the remainder of this process as an example.

(2) Overall Loop Drawing. With information acquired by interviewing cognizant authorities, examining the master plan and drawings of the current airport layout, make a scaled layout of the airport. Create a first-draft co~munications loop system in the process, keeping in mind the possibility of utilizing existing cables and ducts as discussed in the next paragraph, or direct earth burial (DEB). Figure 3-8 shows where three basic loops are created, but which also utilize a portion of the existing duct system.

(a) Present Cable Locations. Locate and identify each of the cable paths and types of presently existing communications, power cables and ducting between the ATCT and each equipment site. Both the communications and power ducts should be shown, because with proper planning, fiber optic communication cables can share the same duct with power cables. These details should be laid out on a facility loop drawing such as shown on figure 3-6. The existing and planned facility loop drawing should show and identify current facility locations, proposed new locations for facilities to be relocated, and planned new facilities.

(b) Fully-Ducted Systems. An example of a fully-ducted cable loop system is shown in figure 3-8. A system of this type is far more versatile. Once the cable system enters the building restricted zone, DEB may be used. The cost effectiveness with regard to the ease and speed of recabling the loop for a faulty section should be assessed.

43

•

8/14/89 6650.8

FIGURE 3-6. EXISTING AND PLANNED FACILITY LOCATIONS

ACCESS ROAOWA V r >. RT I ----=== ---------~------

B

-----------------~ --------- \ --------- I

:

r·--------~-----~----=----------==:::1T~~ '-"

… -=::::M=:AI:N~R:U:NW::AV::::::::::::::::==~----------C:t±:--~~~~--i"" !e C::=I El \

I r-:-1 _-~ r---..J ~ r----------

IM1LSRl g G l [ f :

4. RUNWA Y EXTENSION ± :] : AUXILIARY RUNWAY I ---------------------------------------------------j

LEGEND

I I r

I

I I I

/ "

" /

",,; "

.,.",.------ …

…

.... , , ,

\

\

\

I

I

\

\

I B EXISTING FACILITY (TO BE MOVED)

,

I

\

\ G NEW FACILITY

f----l RUNWAY (ROADWAY) CROSSING

DATE DATE FACILITY INSTALLED COMMISSIONED

'·LOC

2· MAL5R

3· RT

4· RNWY EXT

MOVE

X

I

\

\

\

\ , , , ,

NEW

X

X

X

.... ' … --------'

FLYBY REQ'O

YES

NO

NO

NO

I /

I I

I I

RADAR CLEAR ZONE

44

FIGURE 3-7. IDENTIFICATION OF EXISTING AND PLANNED CABLE RUNS

MAIN RUNWAY

4. RUNWAY EXTENSION

LEGEND --- EXISTING D.E.B. SYSTEM --- EXISTING DUCT SYSTEM B EXISTING FACILITY (TO BE MOVED)

c:z::cz=a PLANNED D.E.B. EXTENSION

--==-==- PLANNED DUCT EXTENSION G NEW FACILITY

!-----i RUNWAY (ROADWA Y) CROSSING

AUXILIARY RUNWAY

I I I

I I

\

\

\

I

\

I I I

, ,

\

/

\

/ /

" "

"

....

""" "

....

....

…

--- --- ....

ACCESS ROADWAY

.... ,

…

....

" \

/

\ ,

\

\

I

I I

\

\

\

I I I I I I I

RADAR CLEAR ZONE

, , ,-------,'

" ,

45

8/14/89 6650.8

(c) Manholes. Excessively long cable runs (in the order of two to three thousand feet) should be considered for direct earth burial (DEB). They should also have some service loops for maintenance or for future use, and be accessible by

strategically placing manholes or handholes at about every 600 feet or fraction thereof, along the path. Round sand should be specified in the trenching operation. Round sand should tend to localize damage and in some cases may, as a result of the cable being able to move more freely between manholes, reduce the possibility of the cable from accidentally being severed during a dig up.

(3) Summary of Loop Physical Length Requirements. With the information shown in figure 3-7, prepare a tabular summary of the cable loop length requirements of all loops similar to that shown in figure 3-9. As a minimum, the table should show:

(a) Loop link from facility to facility,

(b) Loop link length,

(c) Number of manholes/handholes, and

(d) Calculated link losses for every 1000 feet at 1.1 dB at 850 nm and 0.37 dB at 1300 nm depending upon the optical wavelength used.

d. Facility Requirements. This paragraph discusses the facility requirements shown in figure 3-5 as applied to cable routing and equipment layout illustrations in figure 3-10 and figure 3-11.

(1) Cable Runs and Length. For purposes of this example, cable runs and lengths for the ATCT are shown in figure 3-10 from the entry point to the final destination on the second and fourth floors of the ATCT. All tower cab-related interfaces are assumed to be available on the fourth floor. If this is not the case, it may be advisable to consider routing them there to limit the locations of fiber optic interface equipment. All types of fiber optic cable are normally shipped on 2.2-km reels. The lengths of each link (with service and expansion allowances calculated into the total length), and the type of cable (discussed later in this section) for each link must be noted so that the proper amount of the appropriate cable can be allocated to optimize use of the cable based on 2.2-km reels.

(a) Splicing. It is recommended that when at all practicable, cables will be spliced inside a facility shelter. Open field splices should be avoided whenever possible. When it can't be avoided, low-profile, sealed above ground shelters shall be installed to house the splice enclosures. Because of the size and weight of the cable, it is both possible and practical to install full reel lengths in ducts. For paths in which numerous transitions are encountered, it is recommended that the cable be pulled out and coiled in figure-eights on the ground at convenient, intermediate manholes/handholes to limit pulling friction.

(b) Cable leader. Because the cable leader is most apt to be damaged as a result of a long tortuous cable pull, the first twenty-five feet of fiber optic cable should be discarded. An estimate of fiber attenuation utilizing optical time domain reflectometry (OTDR) techniques should be made on the fiber optic cable both

Chap 3 Par 45 Page 39

46

6650.8 8/14/89

before and after installation. This will help ensure that the fibers installed are

continuous without flaw and should conform to allowable attenuation loss within specifications.

(2) Floor Plans. Sample floor plans for the second and fourth floors of the ATCT are shown in figure 3-11. The floor plans also show the location of the new fiber optic interface console and presently existing demarcation boxes. For those sites that have existing facilities with perfectly good copper conductor

interconnections, it may be advisable to install a transfer switch with existing demarcation boxes that will permit easy switchover from fiber optic to copper conductor signal conveyance.

(3) Demarcation Box Signal List. It is necessary to review all cables in the demarcation box which connects that facility to all external facilities to identify each signal, its type, terminal location, input source, output destination, whether or not it passes through a transfer switch, which loop it is located in, and a brief description. This information should be tabulated similar to figure 3-12.

(4) Loop Summary. Once information of the type shown in figure 3-14 has been obtained for all facilities on each loop, a summary for each loop can be generated

in a manner similar to that shown in figure 3-13. In generating this tabular summary, it is required to show each item listed with the input source identified (Input-From), and the destination (Output-To) identified as a fiber optic console at the facility listed.

(5) Standard Components.- In the design of fiber optic systems, National Procurement Specifications have been prepared. This guideline is designed to utilize as much commercially available equipment and materials as possible. In addition, many basic standard items such as cables, transceivers and video transmission equipment are expected to be available from depot stores. Appendix 1 provides guidelines for the representative configurations of airport fiber optic cable loops. Equipment selection should allow for accomodating a nominal 25 perent increase in required capacity.

47

8/14/89 6650.8

FIGURE 3-8. PROPOSED LOOP DUCT SYSTEM

RUNWAY EXTENSION

LEGEND --- EXISTING DUCT SYSTEM

=== PROPOSED LOOP DUCT SYSTEM

D PROPOSED LOOP DUCT SYSTEM 8 EXISTING FACILITY (TO BE MOVED) 8 NEW FACILITY

f---i RUNWAY (ROADWAY) CROSSING

o MANHOLE INTERCONNECTION

AUXILIARY RUNWAY

I I I I

\

\

\

I I

\

\

" / " " I

\ ,

" ,

"

"".,." "

" " "

ACCESS ROADWAY

I : ] --- --- ....

" --------

" " " " , ,

\

\

I I I

\

I

\

\

\

\

I I I I I I I

RADAR CLEAR ZONE

" " " ,

48

6650.8 8/14/89

(6) Determinin~ the Number of Fibers. The final and most important step in designing the communications loop layout is to detail within each loop, the number of fibers required for that loop. A diagram such as figure 3-14 must be generated for each loop, and the length and number of fibers, in increments of six must be determined. (The FAA specified cable has six fibers.) Requirements such as RMM which are known to be emerging should be allocated two fibers. A minimum of two additional fibers per link is recommended for use as spares or for future, and as yet unspecified applications.

FIGURE 3-9. FIBER OPTIC LOOP LINK LOSSES FOR THREE LOOPS

I I IDistance No. IdB Losses dB Losses Loop From To (feet) MH/HH @ 850nm @ 1300nm

ATCT ASR 3750 3 4.2 1.2

ASR ATCT 3750 3 4.2 1.2

8.4 2.4

2 ATCT RT 1590 3 1.75 0.5

RT LOC(1) 2085 3 2.3 0.65

LOC(1) MALSR(1) 1335 2 1.5 0.45

MALSR(1) RVR 2000 3 2.2 0.65

RVR ATCT 2166 4 2.4 0.70

10.15 2.95

3 ATCT GS 1750 2 1.95 0.55

GS MALSR(2) 1000 3 1.1 0.35

MALSR(2) LOC(2) 835 2 0.95 0.30

LOC(2) ATCT 3583 3 3.95 1.15

7.95 2.35

* For duct installation, manholes/handholes (MH/HH) are required at each facility where a building does not exist and/or every 600 feet.

** Loss = 1.1 dB/1000 feet

*** Loss = 0.31 dB/1000 feet

Chap 3 Page 42 Par 45

49

8/14/89 6650. 8

FIBER OPTICS

CABLE

FIGURE 3-10. CABLE ROUTING WITHIN THE ATCT

CAI:ILE SHAFT

I I I I I I

---

----------~ … " ---- -

AIR TRAFFIC "" CONTROL '" TOVVER ' ....

I I I I I I _-------- -:-,",--'-

I

FIBER OPTICS

CABLE

I --- … _--------- I … I " I I I I I I I

I ----------} … ---- I .... I ' I I I I I I

NEW CONSOLE

ACCESS

NEW CONSOLE

ACCESS

RADAR INDICATOR LOCATION (FOURTH FLOOR)

RT DEMARCATION LOCATION (SECOND FLOOR)

SECOND FLOOR RUN 95 FEET FROM ENTRY

FOURTH FLOOR RUN 125 FEET FROM ENTRY

50

6650. 8 8/14/89

FIGURE 3-11. ATCT FACILITY TYPICAL EQUIPMENT LAYOUT

OVERHEAD CABLE RUN CABLE SHAFT 0 E M A OFFICE R K REST. I-- ROOM

STAIR ELEVATOR WELL

~

OVERHEAD CABLE RUN CABLE SHAFT

OFFICE

REST· ROOM

STAIR ELEVATOR OFFICE WEll

FilE - l

FilE -

RT

RT

RT

RT

NEW COMM.

CONS. -

B E N

C H

RADAR

ROOM (DARK)

m … ~ I""""· [ I CABLE 1.0

DEMARK BOX

F.O. CABLE

SECOND FLOOR

FOU RTH FLOOR

51

8/14/89 6650. 8

e. Choices When Planning an Installation. There are some site-dependent decisions to be made when planning a fiber optic cable installation. These decisions are concerned with the various physical types of fiber optic cable available, the type of programmable logic controller to be used, and the planned use of a channel bank for voice channel linkage with the loop.

(1) Physical Types of Fiber Optic Cable. There are several types of fiber optic cable available, the use of each is site dependent upon various physical requirements. Fiber optic cable is available armored, unarmored, and with or without a jet fuel resistant sheath. The six type classifications and respective characteristics is ~hown in table 3-2. Refer to FAA-E-276la, Multimode, Multifiber, Fiber Optic Cable for recommendations on the use of each type. A flow chart to be used as an aid in planning is given in figure 3-15. It provides decision points about proper cable types, and conditions where cost savings may be realized when planning a cable loop. For example, it may not be cost effective to use Type D cable in areas of a loop where jet fuel is not likely to be spilled, use Type A instead.

TABLE 3-2. CLASSIFICATIONS OF FIBER OPTIC CABLE

Resistant to Fiber No. of Mode of Type Fibers Installation Armored Rodents Fuel Spill Lightning

A 6 Exterior-Duct No No No Yes

B 6 Exterior-DEB Yes* Yes No No*

elF 2 Interior only No No No Yes

D 6 Exteri or-Duct No No Yes Yes

E 6 Exterior-DEB Yes* Yes Yes No*

* Use of copper counterpoise system recommended in high lightning areas.

(2) Programmable Logic Controller. A programmable controller (PLC) , hereafter called a programmable logic controller or PLC, provides, monitor and

control functions, multiplexing and demultiplexing, and fault isolation capability for a communications network comprised of counter-rotating rings. There are three types of PLCs, the choice of which is dependent upon capacity and processing requirements, most notably whether the PLC is to be used to reconfigure and control power where speed and interrupt capabilities are important. A brief description of each is given below, and a decision tree shown in figure 3-16 can aid in selecting the proper PLC. Additional guidance is available in FAA-E-2789, Monitor and Control, Programmable Controllers.

Chap 3 Par 45 Page 45

52

6650. 8 8/14/89

FIGURE 3-12. DEMARCATION BOX SUMMARY

LOCATION: ATCT BOX NO. DATE: BY:

Term Signal Input Output L M H 2 3 Description

Normal video ASR X X Normal video

2 Pulse ASR X X ASR antenna change pulse (ACP)

3 Pulse ASR X X ASR antenna reference pulse (ARP)

4 MTI ASR X X Target indicator

5 Beacon ASR X X Beacon

6 Tone GS X X Tone signal for gl ide slope

7 MM ASR X X Meter movement (1 of 6)

8 MM ASR X X Meter movement (2 of 6)

9 MM ASR X X Meter movement (3 of 6)

10 MM ASR X X Meter movement (4 of 6)

11 +48 VDC RT X Transmitter keying (1 of 24)

12 +48 VDC RT X Transmitter keying (2 of 24)

(3) Channel Bank Usa~e. A channel bank unit is a commercially available telephone multiplexing system. A standard configuration of a channel bank is shown on figure 3-17. Given that data modules such as EIA-232, are available, and further assuming that all signals to be transmitted are either compatible or could be made compatible to EIA-232 or voice, all general and voice communication could be transmitted using a channel bank unit. For those airports that have ASR-9 radars, there is no need for ASR video equipment, and all signals could be transmitted using the channel bank. The decision to do so should be evaluated on a site-specific basis by determining the most cost effective design with special regard for overall system reliability and performance.

46.-59. RESERVED.

Chap 3 Page 46 Par 45

53

8/14/89 6650.8

Chap 3

Par 46

FIGURE 3-13. SOURCE/DESTINATION SUMMARY FOR LOOP 1

NlI1lber of Input Interface Mode of Transmission Channels or Frequency Module ASR

PLC2 Chann3l ATCT ASR Output Type Band Required Video1 Bank

47 31 In +28 VDC Low No X

0 In +48 VDC Low No X

7 In AC Low No X

0 6 In Meter movement Low Yes X

2 2 In Voice Medi lI1l Yes X

3 In Video/triggers High Yes X

0 4 In Intermediate Medi lI1l No X frequency pulse

32 39 Out +28 VDC Low No X

7 0 Out AC Low No X

6 0 Out Meter movement Low Yes X

2 2 Out Voice Medi lI1l Yes X

3 Out Video triggers High Yes X

4 0 Out Intermediate

frequency pulse Medium No X

6 9 Out Relay Low No X

Notes:

1. Refer to ASR Video specification, FAA·E-2790.

2. Refer to Programmable Logic Controller specification, FAA-E-2789 and FAA-E-2788.

3. Refer to Channel Bank specification, FAA-E-2810 and FAA-E-2820

54

6650. 8 8/14/89

FIGURE 3-14. DETERMINATION OF FIBER REQUIREMENTS

ASR ATCT

INPUTS ~

31 (28v)

7 (AC) FIBER OPTICS l OOPS

6 ANALOG PLC R ~

MODEM ~ r 1 (48v) T

r R MODEM ~ OUTPUTS T

,

r

T

r

T

39 (28v)

9 RELA YS

'-------

I I MTI r CN:P'~E!l I 1v;~E'J 1 r I ,.~ 1 I I TIWI~lm~ f- ; r

"]

MTI I aN)IT1[}1ER I I VIOEO I r I I I I

I TiWIS'1m~ r-- )

N'"'~

: CllmilcrlEl : I VIDEO I r I irwlSMl~ t- )

f'

)

f'

)

NORW. I IT' 1 I Vloeo 1 r -I aN) • [}lEA J I TFW&IITIEII r J

r

J"

lAPe QJ.U }-

~ l!Oc:JN r ctl{l1T1 [}IER l I vlOeo I ( I I I

I ;1WI~1TT8 t- )

lCPO +

1- QJ.TA

f'

)

lRl'! }- I

OUl

• eEA~

~ 0Kl1T1[}16'1 : lylOEO 1 r 1 TiWIS'1I~ r ) ,

"T

lCP! QJ.U

f

}-

~ ~ FU+2S011

IT91 I FU+Z790

cw

CW T ~

CCW R

ccw ~

~

I r V!CEO I rl RECEIV"ElI

HSYITOi t:

I vlOeo HRECElVER I I r VIDEO 1 HRECE1~

HS'tITOi t: r VIDEO ARECEIVE~ I

HOAIA

1 I VIDEO 1 nRECE;VER r • Hom H SllTOi I

Hom

!

r{VlOEO l- RECElYElI 1 + Hom r-

LJ~

FA1-E-2790

..--

PLC MODEM

~ MODEM

'---

I RESTORE.! 1 I I CIRCUIT I

I RESTt:!IE.! 1 I C1RCUTT I I I RE!TORE! 1 Imam I

I RE!TORE! I I mom r

I I RE!TORE.! l I C:~CUlT r

I RESTORE! I I C:ROJIT r

I I I

FU+2!05 I 11e1 2

OUTPUTS

32 (28v)

7(AC)

6 ANALOG

INPUTS

47(28v)

"'I

MTI

NC~.c..

~

lR=O

eSlCC'l

1::;0

AI'?!

BEAC:>l

lG'!

, (AC)

55

8/14/89 6650. 8

Chap 3

Par 46

FIGURE 3-15. TYPE OF FIBER OPTIC CABLE AND RECOMMENDED INSTALLATION METHOD

*

DUCT

INSTALLATION UNDER RUNWAYS,

PAVED SURFACES,

OR OTHER AREAS

SEAL DUCT

For description of fiber optic types, see specification FAA-E-2761A.

** In areas of high-lightning activity, a copper counterpoise system shall be installed per FAA practices.

Fiber optic cable runs inside a building should use Type C or F cable.

56

6650.8 8/14/89

FIGURE 3-16. PROGRAMMABLE LOGIC CONTROLLER SELECTION CRITERIA

TYPE I TYPE H tYPE III

• TYPICALLY, ANALOG VO REQUIRES 32 POINTS PER CHANNEL

8/14/89 6650.8

FIGURE 3-17. STANDARD INPUT/OUTPUT CONFIGURATION OF CHANNEL BANK UNIT

ATCT

,~--------------~ ~-----------------,

57

2

3 • • • 24

C H A N N

E L

• FULL DUPLEX VOICE (INCLUDING SIGNALLING) CHANNELS

• DIGITAL COMMUNICATION CAPABILITY IS AVAILABLE

RTR

• EITHER. A AND B ARE ROUTED CLOCKWISE ON THE LOOP. AND. C AND D ARE ROUTED COUNTER·ClOCKWISE. OR. VICE VERSA

,

C 2 H A 3 N • N • • E L 24

Page 51 (and 52)

59

APPENDIX 1. CONFIGURATION GUIDELINES

6650.8 Appendix 1

1. GENERAL. This appendix presents configuration information and guidance for planning implementation of airport fiber optic cable loops. The rationale for the four configurations presented herein is discussed in detail in Chapters 2 and 3 of the Airport Fiber Optic Communications Loop Guideline. The four configurations discussed herein assume that certain equipment common to a given configuration is either available or is planned for. Each configuration identifies the basic generic components required, the number required, and the FAA specification that describes the performance requirements for the component.

2. COUNTER-ROTATING RING CONFIGURATION. The counter-rotating ring configuration is comprised of the following components at each node:

Quantity Component Specification

2 (1 for Fiber Optic Transceiver FAA-E-2788 each loop)

a

b

c

d

Chassis and Power Sugplies

(+5, +15, -15, +24 Vdc)

Modem Interface and Adjustable

Delay Lines

Power Control Unit Module

Programmable Logic Controllerc

Analog Inputd (PLC I/O)

VDC Inputd (PLC I/O)