Order 6350.12C Failure of Emergency Function on Common Digitizer Cd) - Cd1 and Cd2 Equipment
This document is cancelled. It may have been replaced. Check the official source before relying on it.
ORDER
SUBJ : FAILURE OF EMERGENCY FUNCTION ON COMMON DIGITIZER (CD) -CD-1 AND CD-2 EQUIPMENT
1 . PURPOSE . This order alerts personnel of a problem with CD-1 and CD-2 operation and provides a routine test to prevent it.
2 . DISTRIBUTION. This order is distributed to the branch level of Airway Facilities Division and the Air Traffic Division, all Airway Facilities System Management Offices (SMO's) having jurisdiction over long range radar/CD-1/CD-2 facilities, and all ARTCC facilities .
3. CANCELLATION. Order SW 6350.1213, Failure of Emergency Function on Common Digitizer (CD)-1/2 Equipment, dated March 2, 1990 is canceled .
4 . ACTION . All affected SMO Managers will take the necessary steps to check the emergency function of the CD-1/2 equipment at each radar site on both 7700 and 7600 codes when radar data processing is in operation, as follows :
a. At the radar site on the CD-1/2 test target generator, set the test target generator to trigger the radio frequency (RF) test set to produce 4 beacon RF test targets at 0, 90, 180, and 270 degrees, all a nominal 30 ACPS wide . Set the beacon RF test set to generate the beacon codes of 7700 or 7600 with a nominal 2 volts of video into the CD-1 /2. Set the range of the beacon targets to a nominal 128 nautical miles .
b. At the ARTCC systems maintenance monitor console (SMMC) plan view display (PVD) with the radar site selected :
(3) The target will be approximately 0 degrees, 90 degrees, 180 degrees, and 270 degrees, at a range of 128 miles .
c . The ARTCC Facility Manager will establish documentation, frequency of test, and coordination between the radar sites and the ARTCC .
Distribution :. A-X (AT/AF) - 3; A-FAF-0 (LTD)
FAA Form 1320-1
(2) A fixed altitude will be flashing with it .
U.S . DEPARTMENT OF TRANSPORTATION
U.S . DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION SW 6350.12C SOUTHWEST REGION
(1) Radar failure (RDOF) or Emergency (EMRG) will be flashing .
2/10/98
Initiated By : ASW-471
SW 6350 .12C 2/10/98
5 . BACKGROUND . The CD-1/2 at a radar site failed to respond to an emergency beacon
FEDERAL AVIATION ADMINISTRATION SW 6350.12C SOUTHWEST REGION
transmission, and as a result, the data block displayed on the PVD in the ARTCC did not flash . The bit
that is set in the CD-1/2 to provide this function was inoperative . This problem could cause an incident
for Air Traffic .
6. EXPLANATION OF CHANGES . This directive has been updated to reflect current Airway
Facilities field organizational titles .
A Marcos Costilla Manager, Airway Facilities Division