ORDER DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION SW 6200. 6

ORDER DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION SW 6200. 6

SOUTHWEST REGION FORT WORTH, TEXAS 24 Aug 72

SUBJ: SILICON CONTROLLED RECTIFIER (SCR) TEST UNIT

1. PURPOSE. This order transmits a schematic diagram of a Silicon Controlled Rectifier (SCR) test unit.

2. DISTRIBUTION. This order is distributed to Branch level in the Airway Facilities Division and to all Airway Facilities field offices in the Southwest Region.

SUBJ: SILICON CONTROLLED RECTIFIER (SCR) TEST UNIT

3. ACTION. No suitable test equipment is presently provided ta dynamically check Silicon Controlled Rectifiers. Those facilities utilizing such equipment may fabricate an SCR test unit from the schematic diagram in Appendix 1.

Richad R Styben RICHARD R. STRYKER Chief, Airway Facilities Division

Distribution: RAF-3; FAF-O (Normal) Initiated By: ASW-431

SCR TEST UNIT

SCR TEST UNIT

Notes: 1. If lamp glows at full brilliance, the SCR is "shorted."

2. The lamp may be replaced with one of more wattage, if greater load is needed.

3. Peak inverse voltage of SCR should be at least 200 volts.

Off On Q

SW

120V 60W

3 x 2700 0hm 2W

Black

Gate

24 Aug 72

24 Aug 72

Anode

SCR Under

White

700 ma 500 piv

TP

500 Mfd 25V 200 0hm + TP Scope or 1 0hm 25 W Volt 63W TP meter TP

Page

Red

Test

Cathode

Appendix 1 SW 6200.6