Order 1100.33E Regional Facility Review Board and Procedures
This document is cancelled. It may have been replaced. Check the official source before relying on it.
Text read by OCR from a scanned file. Check the original, as some words may be misread.
DEPARTMENT OF TRANSPORTATION ORDER FEDERAL AVIATION ADMINISTRATION EA 1100.33E
DEPARTMENT OF TRANSPORTATION ORDER FEDERAL AVIATION ADMINISTRATION EA 1100.33E
EASTERN REGION Jamaica, N.Y. 11430 1/10/83
SUBJ: REGIONAL FACILITY REVIEW BOARD AND PROCEDURES
1. PURPOSE. This order cntinues in existence a Regional Facility Review Board to insure maximum utilization of agency resources and minimum expenditures for establishment and continuing maintenance of facilities and systens without derogation of public service. It also updates procedures and guidelines for the preparation and submission of Site Selection Reports.
SUBJ: REGIONAL FACILITY REVIEW BOARD AND PROCEDURES
2. DISTRIBUrION. This order is distributed to division level in the Regional Office, section level and above in the Airway Pacilities Division and to all Airway Facilities Sectors.
3. CANCELLATION. Order EA 1100.33D is canceled.
4. APPENDIXES
a. Appendix 1 Sample of Letter Format to be prepared for use by the Chairperson, Regional Facility Review Board for recommending site selection to the Regional Director.
4. APPENDIXES
b. Appendix 2 Sample of Report Format to be used in preparing a site selection analysis.
5. BACKGROUND. The establishment of new facilities and relocation of existing facilities require that all technical, operational and economic factors be fuily considered. Selection of sites for navigation, cumunication and radar aids is governed by technical, operational and economic factors. To insure that all these factors are identified and evaluated, proper documentation is required through review and recammended approval by the Regional Facility Review Board.
6. POLICY. The permanent Facility Review Board will continue in existence. The Board shall review all proposals for location of new facilities and relocation of existing facilities to insure complete cordination and consideration of all aspects and interests, including comparative cost factors.
7. ExCEPTION. Any facility whose location is fixed by its function is exempt from this order. The following facilities are exempt: approach lighting systens, RVR's,VASI's and REIL's.
Distribution: A-XEA-2(-AF), A-XAF-4, FAF-2 (2 CYS), Initiated By:AEA-420 AEA-60 (5 cys)
EA 1100.33E 1/10/83
8. BOARD COMPOSITION AND PROCEDURE.
a. The Regional Facility Review Board shall consist of:
(1) Chairperson - Manager, Airway Facilities Division Alternate - Assistant Manager, Airway Facilities Division
(2) Member - Manager, Flight Standards Division Alternate - Manager, Flight Inspection and Procedures Staff
(3) Member - Manager, Air Traffic Division Alternate - Manager, Plans and Program Branch
(4) Member - Manager, Airports Division Altemate - Assistant Manager, Airports Division
(5) Member - Manager, Logistics Division Alternate - Manager, Real Property Branch
b. A site selection analysis shall be circulated by the Airway Facilities Division to members of the Regional Facility Review Board for recommendation to the Regional Director for approval. In the event of disagreement or need for further analysis the Chairperson may request such meetings as necessary for resolution of areas of disagreement.
c. The Board shall convene as directed by the Chairperson. Normally, a minimum of three working days aivance notification shall be provided.
9. RESPONSIBILITIES
a. The Airway Facilities Division is responsible for the facility site "Selection Decision" contained in the Site Selection Report.
9. RESPONSIBILITIES
b. The Regional Facility Review Board is responsible for reviewing the "Selection Decision" and submitting a fully coordinated recommendation to the Regional Director for approval.
10. PROCEDURES.
a. Preparation and Submission of Analysis. The Airway Facilities Division shall prepare and submit a site selection analysis in a format for Board action without the necessity for any additional research on the Board's part. A typical example is shown as Appendix 1 and Appendix 2. The analysis shall be complete in all details and must include the following:
Page 2 Par. 8
1/10/83 EA 1100.33E
(1) Consideration and development of the essentiality or justification for the facility, including its anticipated life.
(2) Determination as to whether the facility is to be collocated with an existing facility. In cases where collocation is recommended, consideration is to be given to the œost of redesign or new design and modification of an existing facility to enable collocation. If collocation is possible and is not recommended, the justification for noncollocation must be included.
(3) An economic analysis of the most practical alternative is to be made and the basis must be established for the selection of the recammended facility site. The analysis shall include alternatives and a cost estimate for each of these alternatives. Consideration is to be given to site preparation, access roads, power and control lines, property acquisitions and maintenance operational factors such as personnel staffing, travel expenses and other pertinent economic factors. Consideration to. property acquisitions shall include cmparisons of costs over the anticipated life of the facility such as outright purchase or ondemmation of fee simple title, leasing with optionto-purchase, and leasing without option-to-purchase.
(4) An outline of services to be provided and the area of required coverage. A statement shall be made as to whether the recommended facility site will give standard operational results. If this site does not meet full standards, an cutline of differences shall be set forth as well as justification for the recommended facility site based upon operational needs. Reference to siting and operational waivers issued shall be made where applicable.
(5) Consideration must be given to environmental factors. A statement shall be provided indicating that a negative environmental declaration has been approved, is being approved, is being prepared, or that no known factors are expected to preclude the approval of a negative environmental declaration. In the event that an environmental impact statenent is necessary, the reasons and expected ramifications must be explained.
(6) A chart showing the location of existing facilities and any planned known œonstruction in the immediate vicinity of the recammended facility site.
Par. 10 Page 3
EA 1100.33E 1/10/83
Approval. Since construction and installation work cannot be initiated at any new or relocated facility until approval, it is necessary that a fully coordinated recommendation be submitted to the Regional Director at least 30 days prior to the expected or planned date for the issuance of the construetion proposal or the start of Government-force work.
Joseph M."Del Balzo Director
Page4 Par. 10
1/10/83 EA 1100.33E Appendix 1 LETTER FORMAT
DATE:
SUBJECT: Site Selection for No Place VORIAC
FROM: Regional Facility Review Board TO: Director, AEA-1
The Board recommends establishment of the subject facility at: Latitude: 00°-00'-00" Longitude: 00°-00'-00"
This location is 35 miles southeast of Nowhere and 50 miles west of Something, near the Town of Town. Our recommendation is made after full consideration of the attached report fram which the following pertinent factors are abstracted:
The facility is required to provide diversionary routes from Metro to midsouth terminals and relieve the current heavy workload on existing routes.
Within the area dictated by the operational requirenents for this facility, there are no existing facilities with which it culd be collocated.
Extensive reconnaissance revealed only two sites worthy of consideration from the viewpoint of successful site testing, although three sites are evaluated in the attached report. From this evaluation, Site No. 3 was selected.
Manager, Airway Facilities Division
Manager, Flight Standards Division Manager, Air Traffic Division
24 1100.00E 1/10/83 d1x 1
Manege, Aieporte Division Managee, Logissies Division
Director
*Insert incubent's neame
Page2
1/10/83
SECTION I
SECTION I
SECTION II
SECTION III
SECIION IV SECTION
SECTION VI
SECTION VII
EA 1100.33E Appendix 2
SITE SELECTION REPORT FORMAT
TABLE OF CONTENTS
PAGE INTRODUCTION 2 GENERAL DISCUSSION 3 DISCUSSION OF SITE NO. 1 5
DISCUSSION OF SITE NO. 2 DISCUSSION OF SITE NO. 3 EVALUATION OF COMPARATIVE FACIORS AND RECOMMENDATION - SELECIION DECISION 8
- ENCLOSURES
- ENCLOSURES
SITE SELECTION REPORT FORMAT
SECTION I - INTRODUCTION
This report outlines the procedures of site search and site selection in connection with the proposed establishment of a vORTAC in the vicinity of No Place.
The report is submitted for consideration by the Regional Facility Review Board.
SITE SELECTION REPORT FORMAT
SITE SELECTION REPORT FORMAT
SECTION II - GENERAL DISCUSSION
Requirement:
The project was undertaken to meet an operational requirement for a facility to provide diversionary routes from Metro to midsouth terminals and relieve the current heavy workload on existing routes. It is anticipated that the facility will be required for a minimum period of 20 years.
SECTION II - GENERAL DISCUSSION
Location Limitations:
The acceptable location area was not strictly defined but was limited by airway structure requirements for the facility.
Collocation:
Within the area limitations stated above, there are no existing facilities with which the proposed facility could be collocated.
Altemnate Sites:
Only one possible site was found within the area as criginally limited. The operational probabilities of this site were so poor that the area was expanded and two additional sites were found.
Cammon Factors:
There is no apparent variation, between the sites considered, in the costs of facility construction after site preparation, power and control extensions, or maintenance; therefore, these factors are not considered in the following evaluations. Estimates of these costs are given below. All fall within limits normally anticipated and included in budget estimates of allocation requirements.
Maintenance $7,500 per annum
Regional F&E costs: Civil Engineering 8,200 Electronic Engineering 6,600 Construction (w/o access road) 41,700 Nonrecurring power and control 4,000 Electronic installation 31,500 Flight inspection 17,300 $109,300
SITE SELECTION REPORT FORMAT
Coordination:
Prior to testing, the site selection and the proposed access were coordinated with the local Sector Manager and the location was coordinated with the Air Traffic Facility Manager.
SITE SELECTION REPORT FORMAT
After a successful site test, the selection was coordinated with and concurred in by the Air Traffic, Flight Standards and Airway Facilities Divisions.
SITE SELECTION REPORT FORMAT
SECTION III - DISCUSSION OF SITE NO. 1
Location:
Latitude: 00°-00'-00" Longitude: 00°-00'-00"
General Description:
SECTION III - DISCUSSION OF SITE NO. 1
A heavily wooded knoll to 500' MSL, about 1/2 mile west of Route Zero.
Advantages:
This site is nearest the optimum location from the viewpoint of AT requirements.
Disadvantages:
The knoll has gentle slopes and is heavily wooded. It would be necessary to clear a full 1,000' radius and more to clear the immediate horizon. Even then, the farther horizon would be poor. A facility at this site would probably be restricted.
Cost of Comparative Factors:
Site preparation (clearing) $21,600 Access road 5,000 $26,600
Real Property Factors:
Acquisition by lease with option-to-purchase Rental for 2 years @ $5,000 $10,000 Appraisal fee 1,800 Purchase price 50,000 $61,800
Acquisition by lease without option-to-purchase Rental for 20 years @ $7,500 $150,000
SITE SELECTION REPORT FORMAT
SITE SELECTION REPORT FORMAT
SECTION IV - DISCUSSION OF SITE NO. 2
Location:
Latitude:00°-00'-00" Longitude: 00°-00'-00"
General Discussion:
Sky Mountain, a narrow, steep rock ridge to 774' MSL, less than 1/2 mile east of Route Zero. Surmounted by a fire tower.
Advantages:
The location meets AT requirements. The site is the highest in the general area and the facility would give good coverage.
SECTION IV - DISCUSSION OF SITE NO. 2
Disadvantages:
The narrow ridge and steep slopes would require the removal of an excessive amount of rock to obtain an adequate plateau since excavated material could not be placed for embankment. The fire tower would require relocation at Government expense and negotiations with the state would probably be time-consuming.
Cost of Comparative Factors:
Site preparation (rock excavation) $100,000 Relocation of fire tower 12,500 Access road 12,500 $117,500
Real Property Factors:
Acquisition by lease with option-to-purchase Not considered in view of nominal rental costs as shown below.
Acquisition by lease without option-to-purchase Rental for 20 years @ $1 per year 20
SITE SELECTION REPORT FORMAT
SITE SELECTION REPORT FORMAT
SECTION V - DISCUSSION OF SITE NO. 3
Location:
Latitude:00°-00'-00" Longitude: 00°-00'-00"
General Discussion:
Tower Hill, a rounded hilltop to 650' MSL, about 1/2 mile south of a secondary road.
Advantages:
The location meets AT requirements. The site is high enough to give god coverage. The contours are mostly rounded so that excavated material could be used to form the plateau.
SECTION V - DISCUSSION OF SITE NO. 3
Disadvantages:
None, other than its comparative elevation.
Cost of Camparative Factors:
Site preparation (clearing and grading) $13,500 Access road 5,000 $18,500
Real Property Factors:
Acquisition by lease with option-to-purchase Not possible, will lease but refuses to sell.
Acquisition of fee title by condemnation Appraisal Fee $ 1,800 Estimated just campensation 50,000 10% contingency factor against adverse ruling 5,000 Condemnation court œsts 1,200 $58,000
Acquisition by lease without option-to-purchase Rental for 20 years @ $4,000 $80,000
SITE SELECTION REPORT FORMAT
SITE SELECTION REPORT FORMAT
SECTION VI - EVALUIATION OF COMPARATIVE FACTORS AND RECOMMENDATION
Based on the preceding discussions, the following evaluations are made:
1. Site No. 1 is relatively low in elevation, the cost of site preparation is difficult to determine accurately and camparative costs would be at least as high as those for Site No. 3. It presents a very low probability of successful flight test.
SECTION VI - EVALUIATION OF COMPARATIVE FACTORS AND RECOMMENDATION
2. The cost of preparing Site No. 2 for a test is excessive.
3. Site No. 3 meets AT requirements, is the most economical and has been successfully tested.
SELECTION DECISION:
We recaumend the establishment of the No Place vORTAC at Site No. 3. We further recammend the acquisition of property rights in fee simple title by condennation.
SITE SELECTION REPORT FORMAT
SITE SELECTION REPORT FORMAT
SECTION VII - ENCLOSURES
Quadrangle Sheet (title) showing the location of the three sites evaluated. 2. Drawing 1-0-0000-1, "No Place vORTAC - Vicinity Sketch" 3. Drawing 1-0-0000-2, "No Place vORrAC - Plot Layout"