76 FR 44246 Special Conditions: Boeing Model 747-8 Series Airplanes; Overhead Flight Attendant Rest Compartment

These special conditions are issued for Boeing Model 747-8

Official source ↗ Official PDF ↗

14 CFR Part 25

[Docket No. NM456; Special Conditions No. 25-442-SC]

Special Conditions: Boeing Model 747-8 Series Airplanes; Overhead

Flight Attendant Rest Compartment

AGENCY: Federal Aviation Administration (FAA), DOT.

ACTION: Final special conditions.

SUMMARY: These special conditions are issued for Boeing Model 747-8

series airplanes. These airplanes will have novel or unusual design

series airplanes. These airplanes will have novel or unusual design

features associated with the installation of an overhead flight

attendant rest compartment. The applicable airworthiness regulations do

not contain adequate or appropriate safety standards for these design

features. These special conditions contain the additional safety

standards that the Administrator considers necessary to establish a

standards that the Administrator considers necessary to establish a

level of safety equivalent to that established by the existing

airworthiness standards. Additional special conditions will be issued

for other novel or unusual design features of Boeing 747-8 airplanes.

DATES: Effective Date: August 24, 2011.

For Further Information Contact

FOR FURTHER INFORMATION CONTACT: Jayson Claar, FAA, Airframe/Cabin

Safety Branch, ANM-115, Transport Standards Staff, Transport Airplane

Directorate, Aircraft Certification Service, 1601 Lind Avenue, SW.,

Renton, Washington 98055-4056; telephone (425) 227-2194; facsimile

(425) 227-1149.

Supplementary Information

SUPPLEMENTARY INFORMATION:

Background

On November 4, 2005, The Boeing Company, P.O. Box 3707, Seattle, WA

98124, applied for an amendment to Type Certificate Number A20WE to

include the new Model 747-8 passenger airplane. Boeing later applied

for, and was granted, an extension of time for the amended type

certificate, which changed the effective application date to December

certificate, which changed the effective application date to December

31, 2006. The Model 747-8 is a derivative of the 747-400. The Model

747-8 is a four-engine jet transport airplane that will have a maximum

takeoff weight of 975,000 pounds and new General Electric GEnx-2B67

engines. The Model 747-8 will have two flight crew and the capacity to

engines. The Model 747-8 will have two flight crew and the capacity to

carry 605 passengers.

Type Certification Basis

Under the provisions of Title 14, Code of Federal Regulations (14

CFR) 21.101, Boeing must show that the Model 747-8 meets the applicable

provisions of part 25, as amended by Amendments 25-1 through 25-120,

plus amendment 25-127 for § 25.795(a), except for earlier

amendments as agreed upon by the FAA. These regulations will be

amendments as agreed upon by the FAA. These regulations will be

incorporated into Type Certificate No. A20WE after type certification

approval of the 747-8.

In addition, the certification basis includes other regulations,

special conditions and exemptions that are not relevant to these

special conditions. Type Certificate No. A20WE will be updated to

special conditions. Type Certificate No. A20WE will be updated to

include a complete description of the certification basis for these

airplanes. If the Administrator finds that the applicable airworthiness

regulations (i.e., 14 CFR part 25) do not contain adequate or

appropriate safety standards for the 747-8 because of a novel or

appropriate safety standards for the 747-8 because of a novel or

unusual design feature, special conditions are prescribed under the provisions of § 21.16.

In addition to the applicable airworthiness regulations and special

conditions, the 747-8 must comply with the fuel vent and exhaust

emission requirements of 14 CFR part 34 and the noise certification

emission requirements of 14 CFR part 34 and the noise certification

requirements of 14 CFR part 36.

Special conditions, as defined in § 11.19, are issued under

§ 11.38, and become part of the type certification basis under

§ 21.101.

Special conditions are initially applicable to the model for which

they are issued. Should the type certificate for that model be amended

later to include any other model or series that incorporates the same

later to include any other model or series that incorporates the same

or similar novel or unusual design feature, or should any other model

or series already included on the same type certificate be modified to

incorporate the same or similar novel or unusual design feature, the

special conditions would also apply to the other model or series under

special conditions would also apply to the other model or series under

§ 21.101.

Compliance with these special conditions does not relieve the

applicant from the existing airplane certification basis requirements.

One particular area of concern is that installing an overhead flight

attendant rest (OFAR) compartment creates a smaller compartment volume

attendant rest (OFAR) compartment creates a smaller compartment volume

within the overhead area of the airplane. The applicant must comply

with the requirements of Sec. § 25.365(e), (f), and (g), for the

OFAR compartment, as well as any other airplane compartments whose

decompression characteristics are affected by the installation of an

OFAR compartment. Compliance with the environmental regulations

OFAR compartment. Compliance with the environmental regulations

(Sec. § 25.831, 25.832, and 25.841) must be demonstrated for all

phases of flight when occupants are present.

Novel or Unusual Design Features

While the installation of an OFAR compartment is not a new concept

for large transport category airplanes, each compartment design has

unique features by virtue of its design, location, and use on the

unique features by virtue of its design, location, and use on the

airplane. Crew rest compartments have been installed and certified in

the main passenger cabin area of Model 777-200 and -300 series

airplanes and the overhead area of the passenger compartment of Model

777-200 airplanes. Other crew rest compartments have been installed

777-200 airplanes. Other crew rest compartments have been installed

below the passenger cabin area adjacent to the cargo compartment.

Similar overhead crew rest compartments have also been installed on

Model 747 series airplanes. The modification is evaluated with respect

to the interior and assessed in accordance with the certification basis

of the airplane. However, part 25 does not provide all of the

requirements for crew rest compartments within the overhead area of the

requirements for crew rest compartments within the overhead area of the

passenger compartment. Further, these special conditions do not negate

the need to address other applicable part 25 regulations.

Due to the novel or unusual features associated with the

installation of this OFAR compartment, special conditions are

considered necessary to provide a level of safety equal to that

considered necessary to provide a level of safety equal to that

established by the airworthiness regulations incorporated by reference

in the type certificate.

Operational Evaluations and Approval

These special conditions outline requirements for overhead crew

rest compartment design approvals, including the OFAR compartment,

(i.e., type design changes and supplemental type certificates)

(i.e., type design changes and supplemental type certificates)

administered by the FAA's Aircraft Certification Service.

Procedures must be developed to assure that a crewmember entering

the OFAR compartment through the vestibule to fight a fire will examine

the vestibule and the lavatory areas for the source of the fire prior

to entering the remaining areas of the OFAR compartment. These

to entering the remaining areas of the OFAR compartment. These

procedures are intended to assure that the source of the fire is not

between the crewmember and the primary exit. In the event a fire source

is not immediately self-evident to the firefighter, the firefighter

should check for potential fire sources at areas closest to the primary

exit first, then proceed to check areas in such a manner that the fire

exit first, then proceed to check areas in such a manner that the fire

source, when found, would not be between the firefighter and the

primary exit. Procedures describing methods to search the overhead crew

rests for fire source(s) must be transmitted to the operator for

incorporation into its training programs and appropriate operational

incorporation into its training programs and appropriate operational

manuals.

Discussion of the Special Conditions

In general, the requirements listed in these special conditions are

similar to those previously approved in earlier certification programs,

such as the Model 777-200 series airplanes and Model 747 overhead crew

rest compartments. These special conditions establish seating,

communication, lighting, personal safety, and evacuation requirements

communication, lighting, personal safety, and evacuation requirements

for the OFAR compartment. In addition, passenger information signs,

supplemental oxygen, and a seat or berth for each occupant of the OFAR

compartment are required. These items are necessary because of

turbulence and/or decompression. When applicable, the requirements

parallel the existing requirements for a lower deck service compartment

parallel the existing requirements for a lower deck service compartment

and provide an equivalent level of safety to that provided for main

deck occupants.

On Model 777 series airplanes, crew rest compartments have been

installed and certified in the main passenger cabin area, above the

main passenger area, and below the passenger cabin area adjacent to the

main passenger area, and below the passenger cabin area adjacent to the

cargo compartment. Also, overhead crew rest compartments have been

installed on Model 747 series airplanes.

The FAA issued special conditions that contain the additional

safety standards that must be met for the OFAR compartments on Boeing

Model 747 and 777 series airplanes. FAA Special Condition 25-ANM-16 was

Model 747 and 777 series airplanes. FAA Special Condition 25-ANM-16 was

issued in 1987 to provide adequate safety standards for the 747-300 and

747-400 Door 5 Overhead Crew Rests, and amended in 1997 (25-ANM-16A) to

address design changes in the 747-400 Door 5 Overhead Crew Rest. For

Boeing Model 777 series airplanes, the FAA issued Special Conditions

Boeing Model 777 series airplanes, the FAA issued Special Conditions

No. 25-230-SC, dated April 9, 2003, for overhead crew rest compartments

allowed to be occupied during flight and Special Conditions No. 25-260-

SC, dated April 14, 2004, for overhead flight crew rest (OFCR)

compartments allowed to be occupied during taxi, take-off, and landing,

SC, dated April 14, 2004, for overhead flight crew rest (OFCR)

as well as during flight.

Special Condition No. 1

This special condition requires the seats and berths to be

certified to the maximum flight loads. Due to the location and

configuration of the OFAR compartment, occupancy during taxi, take-off,

and landing is prohibited, and occupancy is limited to crewmembers

and landing is prohibited, and occupancy is limited to crewmembers

during flight. Occupancy would be limited to 12 in an OFAR compartment,

or the combined total of approved seats and berths in the OFAR,

whichever is less. This special condition has the requirements for:

[cir] Door access and locking,

[cir] Ashtray installation,

[cir] Placards to prohibit passenger access,

[cir] Access by crewmembers not trained in evacuation procedures,

[cir] Smoking, and

[cir] Hazardous quantities of flammable fluids, explosives, or

other dangerous cargo.

The phrase "hazardous quantities" as used in this special

condition permits trained crewmembers to continue to carry baggage

condition permits trained crewmembers to continue to carry baggage

containing minute quantities of flammable fluids (e.g., finger nail

polish and aerosol hairspray) that would pose no threat to the airplane

or its occupants. This wording is consistent with the existing wording

of Sec. § 25.831(d), 25.855(h)(2), 25.857(b)(2), 25.857(c)(3), and 25.1353(c)(3).

Special Condition No. 2

Special Condition No. 2

The purpose of this special condition is to prevent occupants from

being trapped in the OFAR compartment if there is an emergency. The

special condition requires at least two emergency evacuation routes

that could be used by each occupant of the OFAR compartment to rapidly

evacuate to the main cabin. These two routes must be sufficiently

evacuate to the main cabin. These two routes must be sufficiently

separated to minimize the possibility of an event rendering both routes

inoperative. The main entry route meeting the appropriate requirements

may be utilized as one of the emergency evacuation routes, or, as an

alternative, two other emergency routes must be provided. The intent of

Special Condition No. 2(b) is to ensure that one of the two routes

Special Condition No. 2(b) is to ensure that one of the two routes

would be clear of moving occupants under most foreseeable

circumstances.

Special Condition No. 2(b) identifies the three issues that should

be considered for egress routes. First, occupied passenger seats are

not considered an impediment to the use of an egress route (for

example, the egress route drops into one row of seats by means of a

example, the egress route drops into one row of seats by means of a

hatch) provided that the seated occupants do not inhibit the opening of

the egress route (for example, a hatch).

Second, an egress route may utilize areas where normal movement of

passengers occurs if it is demonstrated that the passengers would not

impede egress to the main deck. If the egress means (a hatch in this

impede egress to the main deck. If the egress means (a hatch in this

design) opens into a main aisle, cross aisle, or galley complex to an

extent that it contacts a standing ninety-fifth percentile male, then

the contact should only momentarily interrupt the opening of the egress

hatch. The interruption to the egress means can be considered momentary

hatch. The interruption to the egress means can be considered momentary

if the egress means would continue to open normally once the person has

moved out of the way.

Third, the escape hatch should be provided with a means to prevent

it from being inadvertently closed by a passenger on the main deck.

This will ensure main deck passengers can not prevent the overhead crew

This will ensure main deck passengers can not prevent the overhead crew

rest occupants from using the escape route. The crew should be able to

stow the escape hatch prior to landing.

Training requirements for the OFAR compartment occupants are

included in this special condition.

rest occupants from using the escape route. The crew should be able to

To clarify how compliance can be shown to Special Condition No.

2(a) new qualitative and quantitative criteria have been added to this

special condition since the issuance of Special Conditions No. 25-192-

SC.

Special Condition No. 3

This special condition requires each evacuation route to be

designed for and have procedures established for moving an

designed for and have procedures established for moving an

incapacitated person from the OFAR compartment to the main deck.

Additional assistants to evacuate an incapacitated person may ascend up

to one half the elevation change from the main deck to the OFAR

compartment, or to the first landing, whichever is lower. Where the

escape route is over seats, this special condition allows for five

escape route is over seats, this special condition allows for five

passenger seats to be emptied when demonstrating evacuation of an

incapacitated person.

Special Condition No. 4

This special condition requires exit signs; placards for evacuation

routes; and illumination for signs, placards, and door handles. This

special condition allows the use of exit signs with a reduced

special condition allows the use of exit signs with a reduced

background area. The material surrounding the sign must be light in

color to more closely match and enhance the illuminated background of

the sign that has been reduced in area (letter size stays the same).

Signs with a reduced background area have been allowed under previous

Signs with a reduced background area have been allowed under previous

equivalent level of safety findings for small transport executive jets.

Special Condition No. 5

This special condition requires an emergency lighting system to

prevent the occupants from being isolated in a dark area due to loss of

the normal OFAR compartment lighting. The emergency lighting must be

activated under the same conditions as the main deck emergency lighting

activated under the same conditions as the main deck emergency lighting

system.

Special Condition No. 6

This special condition requires a two-way voice communication and

public address speaker(s) to alert the occupants of an in-flight

emergency. Also required is a system to alert the OFAR compartment

emergency. Also required is a system to alert the OFAR compartment

occupants of a decompression event and to don oxygen masks.

Special Condition No. 7

This special condition requires a means to inform occupants of the

OFAR compartment of an emergency. Also, after certain failures, power

must be maintained to the emergency alarm system for a specific period

must be maintained to the emergency alarm system for a specific period

of time.

Special Condition No. 8

This special condition requires a means that is readily detectable

by seated or standing OFAR compartment occupants to indicate when seat

belts should be fastened. The requirement for visibility of the sign by

standing occupants may be met by a general area sign that is visible to

occupants standing in the main floor area or corridor of the OFAR

occupants standing in the main floor area or corridor of the OFAR

compartment. It would not be essential that the sign be visible from

every possible location in the OFAR compartment. However, the sign

should not be remotely located or located where it may be easily

obscured.

Special Condition No. 9

Special Condition No. 9

This special condition requires the OFAR compartment, which is

remotely located from the passenger cabin, to be equipped with the

following tools for firefighting: a hand-held fire extinguisher,

protective breathing equipment (PBE), and a flashlight.

This requirement has been modified from previously issued Special

Conditions No. 25-192-SC to clarify how it should be interpreted

Conditions No. 25-192-SC to clarify how it should be interpreted

relative to the requirements of § 25.1439(a). Amendment 25-38

modified the requirements of § 25.1439(a) by adding, "In addition,

protective breathing equipment must be installed in each isolated

separate compartment in the airplane, including upper and lower lobe

galleys, in which crewmember occupancy is permitted during flight for

galleys, in which crewmember occupancy is permitted during flight for

the maximum number of crewmembers expected to be in the area during any

operation." The requirements of § 25.1439(a) apply to the OFAR

compartment, which is an isolated separate compartment. However, the

PBE requirements for isolated separate compartments of § 25.1439(a)

are not appropriate because the OFAR compartment is novel and unusual

are not appropriate because the OFAR compartment is novel and unusual

in terms of the number of occupants. In 1976 when Amendment 25-38 was

adopted, underfloor galleys were the only isolated compartments that

had been certificated with a maximum of two crewmembers expected to

occupy those galleys. Special Condition No. 9 addresses OFAR

compartments that can accommodate up to 12 crewmembers. This large

compartments that can accommodate up to 12 crewmembers. This large

number of occupants in an isolated compartment was not envisioned at

the time Amendment 25-38 was adopted. In the event of a fire, an

occupant's first action should be to leave the confined space, unless

the occupant(s) is fighting the fire. It is not appropriate for all

OFAR compartment occupants to don PBE. Taking the time to don the PBE

OFAR compartment occupants to don PBE. Taking the time to don the PBE

would prolong the time for an occupant's emergency evacuation and

possibly interfere with efforts to extinguish the fire.

Special Condition No. 10

This special condition requires a smoke detection system and

appropriate warnings since the OFAR compartment is remotely located

from the main passenger cabin and will not always be occupied. The

from the main passenger cabin and will not always be occupied. The

smoke detection system must be capable of detecting a fire throughout

the OFAR including occupiable areas of the compartment created by the

installation of a curtain or door.

Special Condition No. 11

This special condition requires the OFAR compartment to be designed

so fires within the compartment can be controlled without having to

so fires within the compartment can be controlled without having to

enter the compartment; or, the design of the access provisions must

allow crew equipped for firefighting to have unrestricted access to the

compartment. The time for a crewmember on the main deck to react to the

fire alarm, don firefighting equipment, and gain access must not exceed

fire alarm, don firefighting equipment, and gain access must not exceed

the time for the OFAR compartment to become smoke filled, making it

difficult to locate the fire source.

Special Condition No. 12

This special condition requirement concerning fires within the

compartment was developed for, and applied to, lower lobe crew rest

compartments in Model 777-200 and -300 series airplanes. It was not

compartments in Model 777-200 and -300 series airplanes. It was not

applied to the overhead crew rest compartment in earlier certification

programs such as the Model 747 airplanes. The Model 747 special

conditions were issued before the new part 25 flammability requirements

were developed. This requirement originated from a concern that a fire

in an unoccupied overhead crew rest compartment could spread into the

in an unoccupied overhead crew rest compartment could spread into the

passenger compartment, or affect other vital systems, before it could

be extinguished. This special condition would require either the

installation of a manually activated fire containment system that is

accessible from outside the OFAR compartment, or a demonstration that

the crew could satisfactorily perform the function of extinguishing a

the crew could satisfactorily perform the function of extinguishing a

fire under the prescribed conditions. A manually activated built-in

fire extinguishing system would be required only if a crewmember could

not successfully locate and extinguish the fire during a demonstration

not successfully locate and extinguish the fire during a demonstration

where the crewmember is responding to the alarm.

The OFAR compartment smoke or fire detection and fire suppression

systems (including airflow management features which prevent hazardous

quantities of smoke or fire extinguishing agent from entering any other

compartment occupied by crewmembers or passengers) is considered

compartment occupied by crewmembers or passengers) is considered

complex in terms of paragraph 6d of Advisory Circular (AC) 25.1309-1A,

System Design and Analysis. In addition, the FAA considers failure of

the OFAR compartment fire protection system (i.e., smoke or fire

detection and fire suppression systems) in conjunction with an OFAR

fire to be a catastrophic event. Based on the "Depth of Analysis

Flowchart" shown in Figure 2 of AC 25.1309-1A, the depth of analysis

Flowchart" shown in Figure 2 of AC 25.1309-1A, the depth of analysis

should include both qualitative and quantitative assessments (reference

paragraphs 8d, 9, and 10 of AC 25.1309-1A). In addition, it should be

noted that hazardous quantities of flammable fluids, explosives, or

other dangerous cargo are prohibited from being carried in the OFAR

other dangerous cargo are prohibited from being carried in the OFAR

compartment, a prohibition addressed in Special Condition No. 1(a)(5).

The requirements to enable crewmember(s) to quickly enter the OFAR

compartment and locate a fire source inherently places limits on the

amount of baggage that may be carried and the size of the OFAR

compartment. The OFAR compartment is limited to stowing crew personal

luggage and is not intended for stowing cargo or passenger baggage. The

luggage and is not intended for stowing cargo or passenger baggage. The

design of such a system to include cargo or passenger baggage would

require additional requirements to ensure safe operation.

During the one-minute smoke detection time, penetration of a small

quantity of smoke from the OFAR compartment into an occupied area is

acceptable for this airplane configuration. The FAA finds this

acceptable for this airplane configuration. The FAA finds this

acceptable based on the limitations placed in this and other associated

special conditions. The FAA position is predicated on the fact that

these special conditions place sufficient restrictions on the quantity

and type of material allowed in crew carry-on bags that the threat from

a fire in this remote area would be equivalent to that experienced in

a fire in this remote area would be equivalent to that experienced in

the main cabin.

Special Condition No. 13

This special condition requires that the oxygen equipment and a

supplemental oxygen deployment warning for the OFAR compartment be

equivalent to that provided for main deck passengers. Procedures must

be established for OFAR compartment occupants to follow in the event of

be established for OFAR compartment occupants to follow in the event of

decompression.

Special Condition No. 14

This special condition has the requirements for a divided OFAR

compartment to address supplemental oxygen equipment and deployment

means, signs, placards, curtains, doors, emergency illumination,

compartment to address supplemental oxygen equipment and deployment

alarms, seat belt fasten signals, and evacuation routes.

The wording in Special Condition No. 14(a) was modified from

previously issued special conditions to clarify that oxygen masks are

not required in common areas where seats or berths are not installed. A

visual indicator to don oxygen masks is required in these areas. The

visual indicator is in addition to the aural alert for donning oxygen

visual indicator is in addition to the aural alert for donning oxygen

masks.

Special Condition No. 15

For lavatories or other small areas within an OFAR compartment,

this special condition eliminates the requirements for flight deck

communication as required by Special Condition No. 6, and emergency

fire fighting and protective equipment as required by Special Condition

fire fighting and protective equipment as required by Special Condition

No. 9.

Special Condition No. 16

This special condition requires a fitted waste disposal receptacle

to be equipped with an automatic fire extinguisher.

Special Condition No. 17

This special condition requires the materials in the OFAR

Special Condition No. 17

compartment to meet the flammability requirements of § 25.853(a),

and the mattresses and seat cushions to meet the fire blocking

requirements of § 25.853(c).

Special Condition No. 18

To clarify the applicability, this special condition reiterates the

existing requirements for the main deck lavatory. OFAR compartment

lavatories are required to comply with the existing rules on lavatories

lavatories are required to comply with the existing rules on lavatories

in the absence of other specific requirements. In addition, any

lavatory located in the OFAR compartment must also meet the

requirements of Special Condition No. 10 for smoke detection due to its

placement in this remote area.

Special Condition No. 19

Special Condition No. 19

This special condition requires establishing fire protection

procedures for the OFAR compartment based on the size of the

compartment (compartment interior volume). This special condition has

been revised from previously issued special conditions for other model

airplanes because of the introduction of larger stowage compartments

airplanes because of the introduction of larger stowage compartments

into the OFAR compartment. The fire protection requirements for stowage

compartments in the OFAR compartment are more stringent than those for

stowage in the main passenger cabin because the OFAR compartment is a

remote area that can remain unoccupied for long periods of time in contrast to the main

remote area that can remain unoccupied for long periods of time in contrast to the main

cabin that is under continuous monitoring by the cabin crew and

passengers. For stowage compartments less than 25 ft\3\ the safety

objective of these requirements is to contain the fire. FAA research

indicates that properly constructed compartments meeting the material

indicates that properly constructed compartments meeting the material

requirements will prevent burn through. For stowage compartments

greater than 25 ft\3\ but less than 200 ft\3\ the safety objective is

to detect and contain the fire for sufficient time to allow it to be

extinguished by the crew. The requirements for these sizes of

compartments are comparable to the requirements for Class B cargo

compartments are comparable to the requirements for Class B cargo

compartments. The fire protection requirements are intended to provide

a level of safety for the OFAR compartment that is equivalent to the

level of safety established by the existing regulations for the main

cabin.

level of safety established by the existing regulations for the main

These special conditions along with the original type certification

basis provide the regulatory requirements necessary for certification

of this modification. Other special conditions may be developed, as

needed, based on further FAA review and discussions with the applicant,

manufacturer, and civil aviation authorities.

of this modification. Other special conditions may be developed, as

The addition of galley equipment or a kitchenette incorporating a

heat source (e.g., cook tops, microwaves, or coffee pots), other than a

conventional lavatory or kitchenette hot water heater, within the OFAR

compartment, may require additional special conditions. A hot water

heater is acceptable and will not require issuing additional special

heater is acceptable and will not require issuing additional special

conditions.

The OFAR compartment on the 747-8 series airplanes is located above

the main passenger cabin adjacent to Door 5 and will be accessed from

the main deck by stairs. The OFAR compartment will include a maximum of

10 berths and a bench style seat for a maximum occupancy of 12. An

emergency hatch that opens directly into the main passenger cabin area

emergency hatch that opens directly into the main passenger cabin area

will be provided. A smoke detection system, an oxygen system with audio

warning, emergency backup lighting, information signs, and occupant

amenities will also be provided. Additionally, the OFAR compartment

will only be occupied by trained crew members in flight, not during

will only be occupied by trained crew members in flight, not during

taxi, take-off, or landing.

Discussion of Comments

Notice of proposed special conditions No. 25-11-13-SC for Boeing

Model 747-8 airplanes was published in the Federal Register on May 10,

2011 (76 FR 26949). No comments were received and the special

conditions are adopted as proposed.

Applicability

Applicability

As discussed above, these special conditions are applicable to

Boeing Model 747-8 series airplanes. Should Boeing apply at a later

date for a change to the type certificate to include another model

incorporating the same novel or unusual design features, the special

conditions would apply to that model as well under the provisions of

conditions would apply to that model as well under the provisions of

§ 21.101.

Conclusion

This action affects only certain novel or unusual design features

of Boeing Model 747-8 airplanes. It is not a rule of general

applicability.

List of Subjects in 14 CFR Part 25

Aircraft, Aviation safety, Reporting and recordkeeping

List of Subjects in 14 CFR Part 25

requirements.

The authority citation for these special conditions is as follows:

Authority: 49 U.S.C. 106(g), 40113, 44701, 44702, 44704.

The Special Conditions

Accordingly, pursuant to the authority delegated to me by the

Administrator, the following special conditions are issued as part of

Administrator, the following special conditions are issued as part of

the type certification basis for Boeing Model 747-8 airplanes.

1. Occupancy of the overhead flight attendant rest (OFAR)

compartment is limited to the total number of bunks and seats installed

in that compartment. There must be an approved seat or berth able to

withstand the maximum flight loads when occupied for each occupant

withstand the maximum flight loads when occupied for each occupant

permitted in the OFAR compartment. The maximum occupancy is 12.

(a) Appropriate placards must be located inside and outside each

entrance to the OFAR compartment to indicate:

(1) The maximum number of occupants allowed.

(2) Occupancy is restricted to crewmembers that are trained in the

evacuation procedures for the overhead crew rest compartment.

(3) Occupancy is prohibited during taxi, take-off and landing.

(4) Smoking is prohibited in the OFAR compartment.

(5) Stowage in the OFAR compartment area is limited to crew

personal luggage. The stowage of cargo or passenger baggage is not

personal luggage. The stowage of cargo or passenger baggage is not

allowed.

(b) At least one ashtray must be located on both the inside and the

outside of any entrance to the OFAR compartment.

(c) Passengers must be prevented from entering the OFAR compartment

in the event of an emergency or when no flight attendant is present.

(d) Any door installed between the OFAR compartment and passenger

cabin must be capable of being quickly opened from inside the

cabin must be capable of being quickly opened from inside the

compartment, even when crowding occurs at each side of the door.

(e) For all doors installed in the OFAR compartment, a means must

be in place to preclude anyone from being trapped inside the OFAR

compartment. If a locking mechanism is installed, it must be capable of

being unlocked from the outside without the aid of special tools. The

being unlocked from the outside without the aid of special tools. The

lock must not prevent opening from the inside of the OFAR compartment

at any time.

2. At least two emergency evacuation routes must be available which

could be used by each occupant of the OFAR compartment to rapidly

evacuate to the main cabin and be able to be closed from the main

evacuate to the main cabin and be able to be closed from the main

passenger cabin after evacuation. In addition--

(a) The routes must be located with sufficient separation within

the OFAR compartment, and between the evacuation routes, to minimize

the possibility of an event rendering both routes inoperative.

the OFAR compartment, and between the evacuation routes, to minimize

Compliance with the requirements of Special Condition No. 2(a) may

be shown by inspection or analysis. Regardless of which method is used,

the maximum acceptable distance between exit openings is 60 feet.

Compliance by Inspection

Inspection may be used to show compliance with Special Condition

No. 2(a). An inspection finding that an OFAR compartment has evacuation

No. 2(a). An inspection finding that an OFAR compartment has evacuation

routes located such that each occupant of the seats and berths has an

unobstructed route to at least one of the evacuation routes regardless

of the location of a fire would be reason for a finding of compliance.

A fire within a berth that only blocks the occupant of that berth from

A fire within a berth that only blocks the occupant of that berth from

exiting the berth need not be considered. Therefore, exits which are

located at opposite ends (i.e., adjacent to opposite end walls) of the

OFAR would require no further review or analysis with regard to exit

OFAR would require no further review or analysis with regard to exit

separation.

Compliance by Analysis

Analysis must show that the OFAR compartment configuration and

interior features allow all occupants of the OFAR to escape the

compartment in the event of a hazard inside or outside of the

compartment. Elements to consider in this evaluation are:

compartment in the event of a hazard inside or outside of the

(1) Fire inside or outside the OFAR compartment, considered

separately, and the design elements used to reduce the available fuel for the fire.

(2) Design elements to reduce the fire ignition sources in the OFAR

compartment.

(3) Distribution and quantity of emergency equipment within the

OFAR compartment.

(4) Structural failure or deformation of components that could

block access to the available evacuation routes (e.g., seats, folding

block access to the available evacuation routes (e.g., seats, folding

berths, and contents of stowage compartments).

(5) An incapacitated person blocking the evacuation routes.

(6) Any other foreseeable hazard not identified above that could

cause the evacuation routes to be compromised.

Analysis must consider design features affecting access to the

evacuation routes. The design features that should be considered

evacuation routes. The design features that should be considered

include, but are not limited to,

[cir] Seat back break over,

[cir] The elimination of rigid structure that reduces access from

one part of the compartment to another,

[cir] The elimination of items that are known to cause hazards,

[cir] The availability of emergency equipment to address fire

hazards,

[cir] The availability of communications equipment,

[cir] Supplemental restraint devices to retain items of mass that

could hinder evacuation if broken loose, and

could hinder evacuation if broken loose, and

[cir] Load path isolation between components that contain the

evacuation routes.

Analysis of the fire threats should be used in determining the

placement of required fire extinguishers and protective breathing

equipment (PBE). This analysis should take into consideration the

possibility of fire in any location in the OFAR compartment. The

possibility of fire in any location in the OFAR compartment. The

location and quantity of PBE and fire extinguishers should allow

occupants located in any approved seats or berths access to the

equipment necessary to fight a fire in the OFAR compartment.

The intent of this special condition is to provide sufficient exit

separation. The exit separation analysis described above should not be

separation. The exit separation analysis described above should not be

used to approve exits which have less physical separation (measured

between the centroid of each exit opening) than the minimums prescribed

below, unless compensating features are identified and submitted to the

below, unless compensating features are identified and submitted to the

FAA for evaluation and approval.

For OFAR compartments with one exit located near the forward or aft

end of an OFAR compartment (as measured by having the centroid of the

exit opening within 20 percent of the total OFAR compartment length

from the forward or aft end of the compartment) the exit separation

should not be less than 50 percent of the total OFAR compartment

should not be less than 50 percent of the total OFAR compartment

length.

For OFAR compartments with neither required exit located near the

forward or aft end of the OFAR compartment (as measured by having the

centroid of the exit opening within 20 percent of the total OFAR

compartment length from the forward or aft end of the compartment) the

exit separation should not be less than 30 percent of the total OFAR

exit separation should not be less than 30 percent of the total OFAR

compartment length.

(b) The routes must be designed to minimize the possibility of

blockage, which might result from fire, mechanical or structural

failure, or persons standing below or against the escape route. One of

the two evacuation routes should not be located where, during times

the two evacuation routes should not be located where, during times

when occupancy is allowed, normal movement by passengers occurs (i.e.,

main aisle, cross aisle or galley complex) that would impede egress

from the OFAR compartment. If an evacuation route is in an area where

normal movement of passengers occurs, it must be demonstrated that

passengers would not impede egress to the main deck. If there is low

passengers would not impede egress to the main deck. If there is low

headroom at or near the evacuation route, provisions must be made to

prevent or to protect occupants of the OFAR compartment from head

injury. The use of evacuation routes must not depend on any powered

device. If the evacuation path is over an area where there are

passenger seats, a maximum of five passengers may be temporarily

passenger seats, a maximum of five passengers may be temporarily

displaced from their seats when evacuating an incapacitated person(s).

If the evacuation procedure involves the evacuee stepping on seats, the

seats must not be damaged to the extent that they would not be

acceptable for occupancy during an emergency landing.

seats must not be damaged to the extent that they would not be

(c) Emergency evacuation procedures, including procedures for

emergency evacuation of an incapacitated occupant from the OFAR

compartment, must be established. All of these procedures must be

transmitted to the operator for incorporation into its training

programs and appropriate operational manuals.

transmitted to the operator for incorporation into its training

(d) A limitation must be included in the airplane flight manual or

other suitable means requiring that crewmembers be trained in the use

of evacuation routes.

3. There must be a means for evacuating an incapacitated person

(representative of a ninety-fifth percentile male) from the OFAR

compartment to the passenger cabin floor. The evacuation must be

compartment to the passenger cabin floor. The evacuation must be

demonstrated for all evacuation routes. A crewmember (a total of one

assistant within the OFAR compartment) may provide assistance in the

evacuation. Additional assistance may be provided by up to three

persons in the main passenger compartment. These additional assistants

must be standing on the floor while providing assistance. For

must be standing on the floor while providing assistance. For

evacuation routes with stairways, the additional assistants may ascend

up to one half the elevation change from the main deck to the OFAR

compartment, or to the first landing, whichever is lower.

4. The following signs and placards must be provided in the OFAR

up to one half the elevation change from the main deck to the OFAR

compartment:

(a) At least one exit sign, located near each exit, meeting the

emergency lighting requirements of § 25.812(b)(1)(i); however, a

sign with a reduced background area of no less than 5.3 square inches

(excluding the letters) may be used, provided it is installed so the

(excluding the letters) may be used, provided it is installed so the

material surrounding the exit sign is light in color (e.g., white,

cream, light beige). If the material surrounding the exit sign is not

light in color, a sign with a minimum of a one-inch wide background

border around the letters is acceptable.

(b) An appropriate placard located conspicuously on or near each

exit defining the location and operating instructions for each

exit defining the location and operating instructions for each

evacuation route.

(c) Placards must be readable from a distance of 30 inches under

emergency lighting conditions.

(d) The evacuation path operating instruction placards required by

Special Condition 4(b) of these special conditions must be illuminated

Special Condition 4(b) of these special conditions must be illuminated

to at least 160 microlamberts under emergency lighting conditions.

5. A means must be available, in the event of failure of the

airplane's main power system, or of the normal OFAR compartment

lighting system, for emergency illumination to be automatically

provided in the OFAR compartment.

lighting system, for emergency illumination to be automatically

(a) This emergency illumination must be independent of the main

lighting system.

(b) The sources of general cabin illumination may be common to both

the emergency and the main lighting systems if the power supply to the

emergency lighting system is independent of the power supply to the

emergency lighting system is independent of the power supply to the

main lighting system.

(c) The illumination level must be sufficient for the occupants of

the OFAR compartment to locate and move to the main passenger cabin

floor by means of each evacuation route.

6. A means must be available for two-way voice communications

between crewmembers on the flight deck and occupants of the OFAR

between crewmembers on the flight deck and occupants of the OFAR

compartment.

Two-way voice communications must also be available between the

occupants of the OFAR compartment and each flight attendant station in

the passenger cabin that is required to have a public address system

microphone per § 25.1423(g). In addition, the public address system

must include provisions to provide only the relevant information to the

must include provisions to provide only the relevant information to the

flight attendants in the OFAR compartment (e.g., fire in flight,

airplane depressurization, or preparation of the compartment occupants

for landing).

7. A means must be available for manually activating an aural

airplane depressurization, or preparation of the compartment occupants

emergency alarm system, audible during normal and emergency conditions,

to enable crewmembers on the flight deck and at each pair of required

floor level emergency exits to alert occupants of the OFAR compartment

of an emergency situation. Use of a public address or crew interphone

Continue reading ↓ 120 of 167 passages shown