76 FR 44246 Special Conditions: Boeing Model 747-8 Series Airplanes; Overhead Flight Attendant Rest Compartment
These special conditions are issued for Boeing Model 747-8
[Docket No. NM456; Special Conditions No. 25-442-SC]
Special Conditions: Boeing Model 747-8 Series Airplanes; Overhead
Flight Attendant Rest Compartment
AGENCY: Federal Aviation Administration (FAA), DOT.
ACTION: Final special conditions.
SUMMARY: These special conditions are issued for Boeing Model 747-8
series airplanes. These airplanes will have novel or unusual design
series airplanes. These airplanes will have novel or unusual design
features associated with the installation of an overhead flight
attendant rest compartment. The applicable airworthiness regulations do
not contain adequate or appropriate safety standards for these design
features. These special conditions contain the additional safety
standards that the Administrator considers necessary to establish a
standards that the Administrator considers necessary to establish a
level of safety equivalent to that established by the existing
airworthiness standards. Additional special conditions will be issued
for other novel or unusual design features of Boeing 747-8 airplanes.
DATES: Effective Date: August 24, 2011.
For Further Information Contact
FOR FURTHER INFORMATION CONTACT: Jayson Claar, FAA, Airframe/Cabin
Safety Branch, ANM-115, Transport Standards Staff, Transport Airplane
Directorate, Aircraft Certification Service, 1601 Lind Avenue, SW.,
Renton, Washington 98055-4056; telephone (425) 227-2194; facsimile
(425) 227-1149.
Supplementary Information
SUPPLEMENTARY INFORMATION:
Background
On November 4, 2005, The Boeing Company, P.O. Box 3707, Seattle, WA
98124, applied for an amendment to Type Certificate Number A20WE to
include the new Model 747-8 passenger airplane. Boeing later applied
for, and was granted, an extension of time for the amended type
certificate, which changed the effective application date to December
certificate, which changed the effective application date to December
31, 2006. The Model 747-8 is a derivative of the 747-400. The Model
747-8 is a four-engine jet transport airplane that will have a maximum
takeoff weight of 975,000 pounds and new General Electric GEnx-2B67
engines. The Model 747-8 will have two flight crew and the capacity to
engines. The Model 747-8 will have two flight crew and the capacity to
carry 605 passengers.
Type Certification Basis
Under the provisions of Title 14, Code of Federal Regulations (14
CFR) 21.101, Boeing must show that the Model 747-8 meets the applicable
provisions of part 25, as amended by Amendments 25-1 through 25-120,
plus amendment 25-127 for § 25.795(a), except for earlier
amendments as agreed upon by the FAA. These regulations will be
amendments as agreed upon by the FAA. These regulations will be
incorporated into Type Certificate No. A20WE after type certification
approval of the 747-8.
In addition, the certification basis includes other regulations,
special conditions and exemptions that are not relevant to these
special conditions. Type Certificate No. A20WE will be updated to
special conditions. Type Certificate No. A20WE will be updated to
include a complete description of the certification basis for these
airplanes. If the Administrator finds that the applicable airworthiness
regulations (i.e., 14 CFR part 25) do not contain adequate or
appropriate safety standards for the 747-8 because of a novel or
appropriate safety standards for the 747-8 because of a novel or
unusual design feature, special conditions are prescribed under the provisions of § 21.16.
In addition to the applicable airworthiness regulations and special
conditions, the 747-8 must comply with the fuel vent and exhaust
emission requirements of 14 CFR part 34 and the noise certification
emission requirements of 14 CFR part 34 and the noise certification
requirements of 14 CFR part 36.
Special conditions, as defined in § 11.19, are issued under
§ 11.38, and become part of the type certification basis under
Special conditions are initially applicable to the model for which
they are issued. Should the type certificate for that model be amended
later to include any other model or series that incorporates the same
later to include any other model or series that incorporates the same
or similar novel or unusual design feature, or should any other model
or series already included on the same type certificate be modified to
incorporate the same or similar novel or unusual design feature, the
special conditions would also apply to the other model or series under
special conditions would also apply to the other model or series under
Compliance with these special conditions does not relieve the
applicant from the existing airplane certification basis requirements.
One particular area of concern is that installing an overhead flight
attendant rest (OFAR) compartment creates a smaller compartment volume
attendant rest (OFAR) compartment creates a smaller compartment volume
within the overhead area of the airplane. The applicant must comply
with the requirements of Sec. § 25.365(e), (f), and (g), for the
OFAR compartment, as well as any other airplane compartments whose
decompression characteristics are affected by the installation of an
OFAR compartment. Compliance with the environmental regulations
OFAR compartment. Compliance with the environmental regulations
(Sec. § 25.831, 25.832, and 25.841) must be demonstrated for all
phases of flight when occupants are present.
Novel or Unusual Design Features
While the installation of an OFAR compartment is not a new concept
for large transport category airplanes, each compartment design has
unique features by virtue of its design, location, and use on the
unique features by virtue of its design, location, and use on the
airplane. Crew rest compartments have been installed and certified in
the main passenger cabin area of Model 777-200 and -300 series
airplanes and the overhead area of the passenger compartment of Model
777-200 airplanes. Other crew rest compartments have been installed
777-200 airplanes. Other crew rest compartments have been installed
below the passenger cabin area adjacent to the cargo compartment.
Similar overhead crew rest compartments have also been installed on
Model 747 series airplanes. The modification is evaluated with respect
to the interior and assessed in accordance with the certification basis
of the airplane. However, part 25 does not provide all of the
requirements for crew rest compartments within the overhead area of the
requirements for crew rest compartments within the overhead area of the
passenger compartment. Further, these special conditions do not negate
the need to address other applicable part 25 regulations.
Due to the novel or unusual features associated with the
installation of this OFAR compartment, special conditions are
considered necessary to provide a level of safety equal to that
considered necessary to provide a level of safety equal to that
established by the airworthiness regulations incorporated by reference
in the type certificate.
Operational Evaluations and Approval
These special conditions outline requirements for overhead crew
rest compartment design approvals, including the OFAR compartment,
(i.e., type design changes and supplemental type certificates)
(i.e., type design changes and supplemental type certificates)
administered by the FAA's Aircraft Certification Service.
Procedures must be developed to assure that a crewmember entering
the OFAR compartment through the vestibule to fight a fire will examine
the vestibule and the lavatory areas for the source of the fire prior
to entering the remaining areas of the OFAR compartment. These
to entering the remaining areas of the OFAR compartment. These
procedures are intended to assure that the source of the fire is not
between the crewmember and the primary exit. In the event a fire source
is not immediately self-evident to the firefighter, the firefighter
should check for potential fire sources at areas closest to the primary
exit first, then proceed to check areas in such a manner that the fire
exit first, then proceed to check areas in such a manner that the fire
source, when found, would not be between the firefighter and the
primary exit. Procedures describing methods to search the overhead crew
rests for fire source(s) must be transmitted to the operator for
incorporation into its training programs and appropriate operational
incorporation into its training programs and appropriate operational
manuals.
Discussion of the Special Conditions
In general, the requirements listed in these special conditions are
similar to those previously approved in earlier certification programs,
such as the Model 777-200 series airplanes and Model 747 overhead crew
rest compartments. These special conditions establish seating,
communication, lighting, personal safety, and evacuation requirements
communication, lighting, personal safety, and evacuation requirements
for the OFAR compartment. In addition, passenger information signs,
supplemental oxygen, and a seat or berth for each occupant of the OFAR
compartment are required. These items are necessary because of
turbulence and/or decompression. When applicable, the requirements
parallel the existing requirements for a lower deck service compartment
parallel the existing requirements for a lower deck service compartment
and provide an equivalent level of safety to that provided for main
deck occupants.
On Model 777 series airplanes, crew rest compartments have been
installed and certified in the main passenger cabin area, above the
main passenger area, and below the passenger cabin area adjacent to the
main passenger area, and below the passenger cabin area adjacent to the
cargo compartment. Also, overhead crew rest compartments have been
installed on Model 747 series airplanes.
The FAA issued special conditions that contain the additional
safety standards that must be met for the OFAR compartments on Boeing
Model 747 and 777 series airplanes. FAA Special Condition 25-ANM-16 was
Model 747 and 777 series airplanes. FAA Special Condition 25-ANM-16 was
issued in 1987 to provide adequate safety standards for the 747-300 and
747-400 Door 5 Overhead Crew Rests, and amended in 1997 (25-ANM-16A) to
address design changes in the 747-400 Door 5 Overhead Crew Rest. For
Boeing Model 777 series airplanes, the FAA issued Special Conditions
Boeing Model 777 series airplanes, the FAA issued Special Conditions
No. 25-230-SC, dated April 9, 2003, for overhead crew rest compartments
allowed to be occupied during flight and Special Conditions No. 25-260-
SC, dated April 14, 2004, for overhead flight crew rest (OFCR)
compartments allowed to be occupied during taxi, take-off, and landing,
SC, dated April 14, 2004, for overhead flight crew rest (OFCR)
as well as during flight.
Special Condition No. 1
This special condition requires the seats and berths to be
certified to the maximum flight loads. Due to the location and
configuration of the OFAR compartment, occupancy during taxi, take-off,
and landing is prohibited, and occupancy is limited to crewmembers
and landing is prohibited, and occupancy is limited to crewmembers
during flight. Occupancy would be limited to 12 in an OFAR compartment,
or the combined total of approved seats and berths in the OFAR,
whichever is less. This special condition has the requirements for:
[cir] Door access and locking,
[cir] Ashtray installation,
[cir] Placards to prohibit passenger access,
[cir] Access by crewmembers not trained in evacuation procedures,
[cir] Smoking, and
[cir] Hazardous quantities of flammable fluids, explosives, or
other dangerous cargo.
The phrase "hazardous quantities" as used in this special
condition permits trained crewmembers to continue to carry baggage
condition permits trained crewmembers to continue to carry baggage
containing minute quantities of flammable fluids (e.g., finger nail
polish and aerosol hairspray) that would pose no threat to the airplane
or its occupants. This wording is consistent with the existing wording
of Sec. § 25.831(d), 25.855(h)(2), 25.857(b)(2), 25.857(c)(3), and 25.1353(c)(3).
Special Condition No. 2
Special Condition No. 2
The purpose of this special condition is to prevent occupants from
being trapped in the OFAR compartment if there is an emergency. The
special condition requires at least two emergency evacuation routes
that could be used by each occupant of the OFAR compartment to rapidly
evacuate to the main cabin. These two routes must be sufficiently
evacuate to the main cabin. These two routes must be sufficiently
separated to minimize the possibility of an event rendering both routes
inoperative. The main entry route meeting the appropriate requirements
may be utilized as one of the emergency evacuation routes, or, as an
alternative, two other emergency routes must be provided. The intent of
Special Condition No. 2(b) is to ensure that one of the two routes
Special Condition No. 2(b) is to ensure that one of the two routes
would be clear of moving occupants under most foreseeable
circumstances.
Special Condition No. 2(b) identifies the three issues that should
be considered for egress routes. First, occupied passenger seats are
not considered an impediment to the use of an egress route (for
example, the egress route drops into one row of seats by means of a
example, the egress route drops into one row of seats by means of a
hatch) provided that the seated occupants do not inhibit the opening of
the egress route (for example, a hatch).
Second, an egress route may utilize areas where normal movement of
passengers occurs if it is demonstrated that the passengers would not
impede egress to the main deck. If the egress means (a hatch in this
impede egress to the main deck. If the egress means (a hatch in this
design) opens into a main aisle, cross aisle, or galley complex to an
extent that it contacts a standing ninety-fifth percentile male, then
the contact should only momentarily interrupt the opening of the egress
hatch. The interruption to the egress means can be considered momentary
hatch. The interruption to the egress means can be considered momentary
if the egress means would continue to open normally once the person has
moved out of the way.
Third, the escape hatch should be provided with a means to prevent
it from being inadvertently closed by a passenger on the main deck.
This will ensure main deck passengers can not prevent the overhead crew
This will ensure main deck passengers can not prevent the overhead crew
rest occupants from using the escape route. The crew should be able to
stow the escape hatch prior to landing.
Training requirements for the OFAR compartment occupants are
included in this special condition.
rest occupants from using the escape route. The crew should be able to
To clarify how compliance can be shown to Special Condition No.
2(a) new qualitative and quantitative criteria have been added to this
special condition since the issuance of Special Conditions No. 25-192-
SC.
Special Condition No. 3
This special condition requires each evacuation route to be
designed for and have procedures established for moving an
designed for and have procedures established for moving an
incapacitated person from the OFAR compartment to the main deck.
Additional assistants to evacuate an incapacitated person may ascend up
to one half the elevation change from the main deck to the OFAR
compartment, or to the first landing, whichever is lower. Where the
escape route is over seats, this special condition allows for five
escape route is over seats, this special condition allows for five
passenger seats to be emptied when demonstrating evacuation of an
incapacitated person.
Special Condition No. 4
This special condition requires exit signs; placards for evacuation
routes; and illumination for signs, placards, and door handles. This
special condition allows the use of exit signs with a reduced
special condition allows the use of exit signs with a reduced
background area. The material surrounding the sign must be light in
color to more closely match and enhance the illuminated background of
the sign that has been reduced in area (letter size stays the same).
Signs with a reduced background area have been allowed under previous
Signs with a reduced background area have been allowed under previous
equivalent level of safety findings for small transport executive jets.
Special Condition No. 5
This special condition requires an emergency lighting system to
prevent the occupants from being isolated in a dark area due to loss of
the normal OFAR compartment lighting. The emergency lighting must be
activated under the same conditions as the main deck emergency lighting
activated under the same conditions as the main deck emergency lighting
system.
Special Condition No. 6
This special condition requires a two-way voice communication and
public address speaker(s) to alert the occupants of an in-flight
emergency. Also required is a system to alert the OFAR compartment
emergency. Also required is a system to alert the OFAR compartment
occupants of a decompression event and to don oxygen masks.
Special Condition No. 7
This special condition requires a means to inform occupants of the
OFAR compartment of an emergency. Also, after certain failures, power
must be maintained to the emergency alarm system for a specific period
must be maintained to the emergency alarm system for a specific period
of time.
Special Condition No. 8
This special condition requires a means that is readily detectable
by seated or standing OFAR compartment occupants to indicate when seat
belts should be fastened. The requirement for visibility of the sign by
standing occupants may be met by a general area sign that is visible to
occupants standing in the main floor area or corridor of the OFAR
occupants standing in the main floor area or corridor of the OFAR
compartment. It would not be essential that the sign be visible from
every possible location in the OFAR compartment. However, the sign
should not be remotely located or located where it may be easily
obscured.
Special Condition No. 9
Special Condition No. 9
This special condition requires the OFAR compartment, which is
remotely located from the passenger cabin, to be equipped with the
following tools for firefighting: a hand-held fire extinguisher,
protective breathing equipment (PBE), and a flashlight.
This requirement has been modified from previously issued Special
Conditions No. 25-192-SC to clarify how it should be interpreted
Conditions No. 25-192-SC to clarify how it should be interpreted
relative to the requirements of § 25.1439(a). Amendment 25-38
modified the requirements of § 25.1439(a) by adding, "In addition,
protective breathing equipment must be installed in each isolated
separate compartment in the airplane, including upper and lower lobe
galleys, in which crewmember occupancy is permitted during flight for
galleys, in which crewmember occupancy is permitted during flight for
the maximum number of crewmembers expected to be in the area during any
operation." The requirements of § 25.1439(a) apply to the OFAR
compartment, which is an isolated separate compartment. However, the
PBE requirements for isolated separate compartments of § 25.1439(a)
are not appropriate because the OFAR compartment is novel and unusual
are not appropriate because the OFAR compartment is novel and unusual
in terms of the number of occupants. In 1976 when Amendment 25-38 was
adopted, underfloor galleys were the only isolated compartments that
had been certificated with a maximum of two crewmembers expected to
occupy those galleys. Special Condition No. 9 addresses OFAR
compartments that can accommodate up to 12 crewmembers. This large
compartments that can accommodate up to 12 crewmembers. This large
number of occupants in an isolated compartment was not envisioned at
the time Amendment 25-38 was adopted. In the event of a fire, an
occupant's first action should be to leave the confined space, unless
the occupant(s) is fighting the fire. It is not appropriate for all
OFAR compartment occupants to don PBE. Taking the time to don the PBE
OFAR compartment occupants to don PBE. Taking the time to don the PBE
would prolong the time for an occupant's emergency evacuation and
possibly interfere with efforts to extinguish the fire.
Special Condition No. 10
This special condition requires a smoke detection system and
appropriate warnings since the OFAR compartment is remotely located
from the main passenger cabin and will not always be occupied. The
from the main passenger cabin and will not always be occupied. The
smoke detection system must be capable of detecting a fire throughout
the OFAR including occupiable areas of the compartment created by the
installation of a curtain or door.
Special Condition No. 11
This special condition requires the OFAR compartment to be designed
so fires within the compartment can be controlled without having to
so fires within the compartment can be controlled without having to
enter the compartment; or, the design of the access provisions must
allow crew equipped for firefighting to have unrestricted access to the
compartment. The time for a crewmember on the main deck to react to the
fire alarm, don firefighting equipment, and gain access must not exceed
fire alarm, don firefighting equipment, and gain access must not exceed
the time for the OFAR compartment to become smoke filled, making it
difficult to locate the fire source.
Special Condition No. 12
This special condition requirement concerning fires within the
compartment was developed for, and applied to, lower lobe crew rest
compartments in Model 777-200 and -300 series airplanes. It was not
compartments in Model 777-200 and -300 series airplanes. It was not
applied to the overhead crew rest compartment in earlier certification
programs such as the Model 747 airplanes. The Model 747 special
conditions were issued before the new part 25 flammability requirements
were developed. This requirement originated from a concern that a fire
in an unoccupied overhead crew rest compartment could spread into the
in an unoccupied overhead crew rest compartment could spread into the
passenger compartment, or affect other vital systems, before it could
be extinguished. This special condition would require either the
installation of a manually activated fire containment system that is
accessible from outside the OFAR compartment, or a demonstration that
the crew could satisfactorily perform the function of extinguishing a
the crew could satisfactorily perform the function of extinguishing a
fire under the prescribed conditions. A manually activated built-in
fire extinguishing system would be required only if a crewmember could
not successfully locate and extinguish the fire during a demonstration
not successfully locate and extinguish the fire during a demonstration
where the crewmember is responding to the alarm.
The OFAR compartment smoke or fire detection and fire suppression
systems (including airflow management features which prevent hazardous
quantities of smoke or fire extinguishing agent from entering any other
compartment occupied by crewmembers or passengers) is considered
compartment occupied by crewmembers or passengers) is considered
complex in terms of paragraph 6d of Advisory Circular (AC) 25.1309-1A,
System Design and Analysis. In addition, the FAA considers failure of
the OFAR compartment fire protection system (i.e., smoke or fire
detection and fire suppression systems) in conjunction with an OFAR
fire to be a catastrophic event. Based on the "Depth of Analysis
Flowchart" shown in Figure 2 of AC 25.1309-1A, the depth of analysis
Flowchart" shown in Figure 2 of AC 25.1309-1A, the depth of analysis
should include both qualitative and quantitative assessments (reference
paragraphs 8d, 9, and 10 of AC 25.1309-1A). In addition, it should be
noted that hazardous quantities of flammable fluids, explosives, or
other dangerous cargo are prohibited from being carried in the OFAR
other dangerous cargo are prohibited from being carried in the OFAR
compartment, a prohibition addressed in Special Condition No. 1(a)(5).
The requirements to enable crewmember(s) to quickly enter the OFAR
compartment and locate a fire source inherently places limits on the
amount of baggage that may be carried and the size of the OFAR
compartment. The OFAR compartment is limited to stowing crew personal
luggage and is not intended for stowing cargo or passenger baggage. The
luggage and is not intended for stowing cargo or passenger baggage. The
design of such a system to include cargo or passenger baggage would
require additional requirements to ensure safe operation.
During the one-minute smoke detection time, penetration of a small
quantity of smoke from the OFAR compartment into an occupied area is
acceptable for this airplane configuration. The FAA finds this
acceptable for this airplane configuration. The FAA finds this
acceptable based on the limitations placed in this and other associated
special conditions. The FAA position is predicated on the fact that
these special conditions place sufficient restrictions on the quantity
and type of material allowed in crew carry-on bags that the threat from
a fire in this remote area would be equivalent to that experienced in
a fire in this remote area would be equivalent to that experienced in
the main cabin.
Special Condition No. 13
This special condition requires that the oxygen equipment and a
supplemental oxygen deployment warning for the OFAR compartment be
equivalent to that provided for main deck passengers. Procedures must
be established for OFAR compartment occupants to follow in the event of
be established for OFAR compartment occupants to follow in the event of
decompression.
Special Condition No. 14
This special condition has the requirements for a divided OFAR
compartment to address supplemental oxygen equipment and deployment
means, signs, placards, curtains, doors, emergency illumination,
compartment to address supplemental oxygen equipment and deployment
alarms, seat belt fasten signals, and evacuation routes.
The wording in Special Condition No. 14(a) was modified from
previously issued special conditions to clarify that oxygen masks are
not required in common areas where seats or berths are not installed. A
visual indicator to don oxygen masks is required in these areas. The
visual indicator is in addition to the aural alert for donning oxygen
visual indicator is in addition to the aural alert for donning oxygen
masks.
Special Condition No. 15
For lavatories or other small areas within an OFAR compartment,
this special condition eliminates the requirements for flight deck
communication as required by Special Condition No. 6, and emergency
fire fighting and protective equipment as required by Special Condition
fire fighting and protective equipment as required by Special Condition
No. 9.
Special Condition No. 16
This special condition requires a fitted waste disposal receptacle
to be equipped with an automatic fire extinguisher.
Special Condition No. 17
This special condition requires the materials in the OFAR
Special Condition No. 17
compartment to meet the flammability requirements of § 25.853(a),
and the mattresses and seat cushions to meet the fire blocking
requirements of § 25.853(c).
Special Condition No. 18
To clarify the applicability, this special condition reiterates the
existing requirements for the main deck lavatory. OFAR compartment
lavatories are required to comply with the existing rules on lavatories
lavatories are required to comply with the existing rules on lavatories
in the absence of other specific requirements. In addition, any
lavatory located in the OFAR compartment must also meet the
requirements of Special Condition No. 10 for smoke detection due to its
placement in this remote area.
Special Condition No. 19
Special Condition No. 19
This special condition requires establishing fire protection
procedures for the OFAR compartment based on the size of the
compartment (compartment interior volume). This special condition has
been revised from previously issued special conditions for other model
airplanes because of the introduction of larger stowage compartments
airplanes because of the introduction of larger stowage compartments
into the OFAR compartment. The fire protection requirements for stowage
compartments in the OFAR compartment are more stringent than those for
stowage in the main passenger cabin because the OFAR compartment is a
remote area that can remain unoccupied for long periods of time in contrast to the main
remote area that can remain unoccupied for long periods of time in contrast to the main
cabin that is under continuous monitoring by the cabin crew and
passengers. For stowage compartments less than 25 ft\3\ the safety
objective of these requirements is to contain the fire. FAA research
indicates that properly constructed compartments meeting the material
indicates that properly constructed compartments meeting the material
requirements will prevent burn through. For stowage compartments
greater than 25 ft\3\ but less than 200 ft\3\ the safety objective is
to detect and contain the fire for sufficient time to allow it to be
extinguished by the crew. The requirements for these sizes of
compartments are comparable to the requirements for Class B cargo
compartments are comparable to the requirements for Class B cargo
compartments. The fire protection requirements are intended to provide
a level of safety for the OFAR compartment that is equivalent to the
level of safety established by the existing regulations for the main
cabin.
level of safety established by the existing regulations for the main
These special conditions along with the original type certification
basis provide the regulatory requirements necessary for certification
of this modification. Other special conditions may be developed, as
needed, based on further FAA review and discussions with the applicant,
manufacturer, and civil aviation authorities.
of this modification. Other special conditions may be developed, as
The addition of galley equipment or a kitchenette incorporating a
heat source (e.g., cook tops, microwaves, or coffee pots), other than a
conventional lavatory or kitchenette hot water heater, within the OFAR
compartment, may require additional special conditions. A hot water
heater is acceptable and will not require issuing additional special
heater is acceptable and will not require issuing additional special
conditions.
The OFAR compartment on the 747-8 series airplanes is located above
the main passenger cabin adjacent to Door 5 and will be accessed from
the main deck by stairs. The OFAR compartment will include a maximum of
10 berths and a bench style seat for a maximum occupancy of 12. An
emergency hatch that opens directly into the main passenger cabin area
emergency hatch that opens directly into the main passenger cabin area
will be provided. A smoke detection system, an oxygen system with audio
warning, emergency backup lighting, information signs, and occupant
amenities will also be provided. Additionally, the OFAR compartment
will only be occupied by trained crew members in flight, not during
will only be occupied by trained crew members in flight, not during
taxi, take-off, or landing.
Discussion of Comments
Notice of proposed special conditions No. 25-11-13-SC for Boeing
Model 747-8 airplanes was published in the Federal Register on May 10,
2011 (76 FR 26949). No comments were received and the special
conditions are adopted as proposed.
Applicability
Applicability
As discussed above, these special conditions are applicable to
Boeing Model 747-8 series airplanes. Should Boeing apply at a later
date for a change to the type certificate to include another model
incorporating the same novel or unusual design features, the special
conditions would apply to that model as well under the provisions of
conditions would apply to that model as well under the provisions of
Conclusion
This action affects only certain novel or unusual design features
of Boeing Model 747-8 airplanes. It is not a rule of general
applicability.
List of Subjects in 14 CFR Part 25
Aircraft, Aviation safety, Reporting and recordkeeping
List of Subjects in 14 CFR Part 25
requirements.
The authority citation for these special conditions is as follows:
Authority: 49 U.S.C. 106(g), 40113, 44701, 44702, 44704.
The Special Conditions
Accordingly, pursuant to the authority delegated to me by the
Administrator, the following special conditions are issued as part of
Administrator, the following special conditions are issued as part of
the type certification basis for Boeing Model 747-8 airplanes.
1. Occupancy of the overhead flight attendant rest (OFAR)
compartment is limited to the total number of bunks and seats installed
in that compartment. There must be an approved seat or berth able to
withstand the maximum flight loads when occupied for each occupant
withstand the maximum flight loads when occupied for each occupant
permitted in the OFAR compartment. The maximum occupancy is 12.
(a) Appropriate placards must be located inside and outside each
entrance to the OFAR compartment to indicate:
(1) The maximum number of occupants allowed.
(2) Occupancy is restricted to crewmembers that are trained in the
evacuation procedures for the overhead crew rest compartment.
(3) Occupancy is prohibited during taxi, take-off and landing.
(4) Smoking is prohibited in the OFAR compartment.
(5) Stowage in the OFAR compartment area is limited to crew
personal luggage. The stowage of cargo or passenger baggage is not
personal luggage. The stowage of cargo or passenger baggage is not
allowed.
(b) At least one ashtray must be located on both the inside and the
outside of any entrance to the OFAR compartment.
(c) Passengers must be prevented from entering the OFAR compartment
in the event of an emergency or when no flight attendant is present.
(d) Any door installed between the OFAR compartment and passenger
cabin must be capable of being quickly opened from inside the
cabin must be capable of being quickly opened from inside the
compartment, even when crowding occurs at each side of the door.
(e) For all doors installed in the OFAR compartment, a means must
be in place to preclude anyone from being trapped inside the OFAR
compartment. If a locking mechanism is installed, it must be capable of
being unlocked from the outside without the aid of special tools. The
being unlocked from the outside without the aid of special tools. The
lock must not prevent opening from the inside of the OFAR compartment
at any time.
2. At least two emergency evacuation routes must be available which
could be used by each occupant of the OFAR compartment to rapidly
evacuate to the main cabin and be able to be closed from the main
evacuate to the main cabin and be able to be closed from the main
passenger cabin after evacuation. In addition--
(a) The routes must be located with sufficient separation within
the OFAR compartment, and between the evacuation routes, to minimize
the possibility of an event rendering both routes inoperative.
the OFAR compartment, and between the evacuation routes, to minimize
Compliance with the requirements of Special Condition No. 2(a) may
be shown by inspection or analysis. Regardless of which method is used,
the maximum acceptable distance between exit openings is 60 feet.
Compliance by Inspection
Inspection may be used to show compliance with Special Condition
No. 2(a). An inspection finding that an OFAR compartment has evacuation
No. 2(a). An inspection finding that an OFAR compartment has evacuation
routes located such that each occupant of the seats and berths has an
unobstructed route to at least one of the evacuation routes regardless
of the location of a fire would be reason for a finding of compliance.
A fire within a berth that only blocks the occupant of that berth from
A fire within a berth that only blocks the occupant of that berth from
exiting the berth need not be considered. Therefore, exits which are
located at opposite ends (i.e., adjacent to opposite end walls) of the
OFAR would require no further review or analysis with regard to exit
OFAR would require no further review or analysis with regard to exit
separation.
Compliance by Analysis
Analysis must show that the OFAR compartment configuration and
interior features allow all occupants of the OFAR to escape the
compartment in the event of a hazard inside or outside of the
compartment. Elements to consider in this evaluation are:
compartment in the event of a hazard inside or outside of the
(1) Fire inside or outside the OFAR compartment, considered
separately, and the design elements used to reduce the available fuel for the fire.
(2) Design elements to reduce the fire ignition sources in the OFAR
compartment.
(3) Distribution and quantity of emergency equipment within the
OFAR compartment.
(4) Structural failure or deformation of components that could
block access to the available evacuation routes (e.g., seats, folding
block access to the available evacuation routes (e.g., seats, folding
berths, and contents of stowage compartments).
(5) An incapacitated person blocking the evacuation routes.
(6) Any other foreseeable hazard not identified above that could
cause the evacuation routes to be compromised.
Analysis must consider design features affecting access to the
evacuation routes. The design features that should be considered
evacuation routes. The design features that should be considered
include, but are not limited to,
[cir] Seat back break over,
[cir] The elimination of rigid structure that reduces access from
one part of the compartment to another,
[cir] The elimination of items that are known to cause hazards,
[cir] The availability of emergency equipment to address fire
hazards,
[cir] The availability of communications equipment,
[cir] Supplemental restraint devices to retain items of mass that
could hinder evacuation if broken loose, and
could hinder evacuation if broken loose, and
[cir] Load path isolation between components that contain the
evacuation routes.
Analysis of the fire threats should be used in determining the
placement of required fire extinguishers and protective breathing
equipment (PBE). This analysis should take into consideration the
possibility of fire in any location in the OFAR compartment. The
possibility of fire in any location in the OFAR compartment. The
location and quantity of PBE and fire extinguishers should allow
occupants located in any approved seats or berths access to the
equipment necessary to fight a fire in the OFAR compartment.
The intent of this special condition is to provide sufficient exit
separation. The exit separation analysis described above should not be
separation. The exit separation analysis described above should not be
used to approve exits which have less physical separation (measured
between the centroid of each exit opening) than the minimums prescribed
below, unless compensating features are identified and submitted to the
below, unless compensating features are identified and submitted to the
FAA for evaluation and approval.
For OFAR compartments with one exit located near the forward or aft
end of an OFAR compartment (as measured by having the centroid of the
exit opening within 20 percent of the total OFAR compartment length
from the forward or aft end of the compartment) the exit separation
should not be less than 50 percent of the total OFAR compartment
should not be less than 50 percent of the total OFAR compartment
length.
For OFAR compartments with neither required exit located near the
forward or aft end of the OFAR compartment (as measured by having the
centroid of the exit opening within 20 percent of the total OFAR
compartment length from the forward or aft end of the compartment) the
exit separation should not be less than 30 percent of the total OFAR
exit separation should not be less than 30 percent of the total OFAR
compartment length.
(b) The routes must be designed to minimize the possibility of
blockage, which might result from fire, mechanical or structural
failure, or persons standing below or against the escape route. One of
the two evacuation routes should not be located where, during times
the two evacuation routes should not be located where, during times
when occupancy is allowed, normal movement by passengers occurs (i.e.,
main aisle, cross aisle or galley complex) that would impede egress
from the OFAR compartment. If an evacuation route is in an area where
normal movement of passengers occurs, it must be demonstrated that
passengers would not impede egress to the main deck. If there is low
passengers would not impede egress to the main deck. If there is low
headroom at or near the evacuation route, provisions must be made to
prevent or to protect occupants of the OFAR compartment from head
injury. The use of evacuation routes must not depend on any powered
device. If the evacuation path is over an area where there are
passenger seats, a maximum of five passengers may be temporarily
passenger seats, a maximum of five passengers may be temporarily
displaced from their seats when evacuating an incapacitated person(s).
If the evacuation procedure involves the evacuee stepping on seats, the
seats must not be damaged to the extent that they would not be
acceptable for occupancy during an emergency landing.
seats must not be damaged to the extent that they would not be
(c) Emergency evacuation procedures, including procedures for
emergency evacuation of an incapacitated occupant from the OFAR
compartment, must be established. All of these procedures must be
transmitted to the operator for incorporation into its training
programs and appropriate operational manuals.
transmitted to the operator for incorporation into its training
(d) A limitation must be included in the airplane flight manual or
other suitable means requiring that crewmembers be trained in the use
of evacuation routes.
3. There must be a means for evacuating an incapacitated person
(representative of a ninety-fifth percentile male) from the OFAR
compartment to the passenger cabin floor. The evacuation must be
compartment to the passenger cabin floor. The evacuation must be
demonstrated for all evacuation routes. A crewmember (a total of one
assistant within the OFAR compartment) may provide assistance in the
evacuation. Additional assistance may be provided by up to three
persons in the main passenger compartment. These additional assistants
must be standing on the floor while providing assistance. For
must be standing on the floor while providing assistance. For
evacuation routes with stairways, the additional assistants may ascend
up to one half the elevation change from the main deck to the OFAR
compartment, or to the first landing, whichever is lower.
4. The following signs and placards must be provided in the OFAR
up to one half the elevation change from the main deck to the OFAR
compartment:
(a) At least one exit sign, located near each exit, meeting the
emergency lighting requirements of § 25.812(b)(1)(i); however, a
sign with a reduced background area of no less than 5.3 square inches
(excluding the letters) may be used, provided it is installed so the
(excluding the letters) may be used, provided it is installed so the
material surrounding the exit sign is light in color (e.g., white,
cream, light beige). If the material surrounding the exit sign is not
light in color, a sign with a minimum of a one-inch wide background
border around the letters is acceptable.
(b) An appropriate placard located conspicuously on or near each
exit defining the location and operating instructions for each
exit defining the location and operating instructions for each
evacuation route.
(c) Placards must be readable from a distance of 30 inches under
emergency lighting conditions.
(d) The evacuation path operating instruction placards required by
Special Condition 4(b) of these special conditions must be illuminated
Special Condition 4(b) of these special conditions must be illuminated
to at least 160 microlamberts under emergency lighting conditions.
5. A means must be available, in the event of failure of the
airplane's main power system, or of the normal OFAR compartment
lighting system, for emergency illumination to be automatically
provided in the OFAR compartment.
lighting system, for emergency illumination to be automatically
(a) This emergency illumination must be independent of the main
lighting system.
(b) The sources of general cabin illumination may be common to both
the emergency and the main lighting systems if the power supply to the
emergency lighting system is independent of the power supply to the
emergency lighting system is independent of the power supply to the
main lighting system.
(c) The illumination level must be sufficient for the occupants of
the OFAR compartment to locate and move to the main passenger cabin
floor by means of each evacuation route.
6. A means must be available for two-way voice communications
between crewmembers on the flight deck and occupants of the OFAR
between crewmembers on the flight deck and occupants of the OFAR
compartment.
Two-way voice communications must also be available between the
occupants of the OFAR compartment and each flight attendant station in
the passenger cabin that is required to have a public address system
microphone per § 25.1423(g). In addition, the public address system
must include provisions to provide only the relevant information to the
must include provisions to provide only the relevant information to the
flight attendants in the OFAR compartment (e.g., fire in flight,
airplane depressurization, or preparation of the compartment occupants
for landing).
7. A means must be available for manually activating an aural
airplane depressurization, or preparation of the compartment occupants
emergency alarm system, audible during normal and emergency conditions,
to enable crewmembers on the flight deck and at each pair of required
floor level emergency exits to alert occupants of the OFAR compartment
of an emergency situation. Use of a public address or crew interphone
Continue reading ↓ 120 of 167 passages shown