Radar Vectors
Civil Air Regulation Historical Issued Jun 19, 1962 AIR-600-Policy and Innovation Division 23 pages Copy saved Nov 21, 2026

CAR 514 Draft Release No. 62-29: Revision to Technical Standard Order C35b "Radio Marker Receiving Equipment Operating in 75 mc. (For Air Carrier Aircraft)

This document is historical. It may have been replaced. Check the official source before relying on it.

Official source ↗ Open PDF

FEDERAL AVIATION AGENCY FLIGHT STANDARDS SERVICE

FEDERAL AVIATION AGENCY FLIGHT STANDARDS SERVICE

Washington 25, D. C.

June 19, 1962

REGULATIONS OF THE ADMINISTRATOR DRAFT RELEASE NO. 62-29

SUBJECT: R e v i s i o n t o T e c h n i c a l S t a n d a r d O r d e r C35b " R a d i o M a r k e r R e c e i v i n g Equipment O p e r a t i n g on 75 mc. ( F o r A i r C a r r i e r A i r c r a f t ) "

REGULATIONS OF THE ADMINISTRATOR DRAFT RELEASE NO. 62-29

The F l i g h t Standards S e r v i c e o f t h e F e d e r a l A v i a t i o n Agency has under c o n s i d e r a t i o n an amendment t o P a r t 514 o f the R e g u l a t i o n s o f t h e A d m i n i s t r a t o r to r e v i s e T e c h n i c a l Standard O r d e r C35b "Radio M a r k e r R e c e i v i n g Equipment O p e r a t i n g on 75 mc. ( F o r A i r C a r r i e r A i r c r a f t " . The reasons t h e r e f o r are s e t f o r t h i n the e x p l a n a t o r y s t a t e m e n t o f t h e a t t a c h e d p r o p o s a l w h i c h i s b e i n g p u b l i s h e d i n the F e d e r a l R e g i s t e r as a n o t i c e o f proposed r u l e m a k i n g .

The F l i g h t Standards S e r v i c e d e s i r e s t h a t a l l persons who w i l l be a f f e c t e d by t h e r e q u i r e m e n t s o f t h i s p r o p o s a l be f u l l y i n f o r m e d as t o i t s e f f e c t upon them and i s t h e r e f o r e c i r c u l a t i n g c o p i e s i n o r d e r t o a f f o r d i n t e r e s t e d persons ample o p p o r t u n i t y t o submit comments as they may d e s i r e .

Because o f t h e l a r g e number o f comments w h i c h we a n t i c i p a t e r e c e i v i n g i n response t o t h i s d r a f t r e l e a s e , we w i l l be u n a b l e t o acknowledge r e c e i p t o f each r e p l y . However, you may be a s s u r e d t h a t a l l comment w i l l be g i v e n c a r e f u l c o n s i d e r a t i o n .

I t s h o u l d be n o t e d t h a t comments s h o u l d be s u b m i t t e d , p r e f e r a b l y i n d u p l i c a t e , t o the Docket S e c t i o n o f t h e F e d e r a l A v i a t i o n Agency, and i n o r d e r to i n s u r e c o n s i d e r a t i o n must be r e c e i v e d on o r before^AuglJS"^ 13» 1962,

F l i g h t Standards S e r v i c e

FEDERAL AVIATION AGENCY

FEDERAL AVIATION AGENCY

FLIGHT STANDARDS SERVICE

(14 CFR 514)

/Regulatory Docket No. I 2 g

Q ; D r a f t Release No. 62-2ff

TECHNICAL STANDARD ORDERS FOR AIRCRAFT MATERIALS

PARTS, PROCESSES AND APPLIANCES

NOTICE OF PROPOSED RULE MAKING

Pursuant t o the a u t h o r i t y delegated t o me by the A d m i n i s t r a t o r

NOTICE OF PROPOSED RULE MAKING

(14 CFR Part 405) n o t i c e i s hereby given t h a t the Federal A v i a t i o n Agency

has under c o n s i d e r a t i o n a proposal t o r e v i s e Section 514.37 o f P a r t 514

o f the Regulations o f the A d m i n i s t r a t o r (14 CFR P a r t 514) by adding a new

t e c h n i c a l standard order. This Technical Standard Order e s t a b l i s h e s

minimum performance standards f o r a i r b o r n e r a d i o marker r e c e i v i n g equipment

o p e r a t i n g on 75 mc. t o be used on c i v i l a i r c r a f t o f the United States

engaged i n a i r c a r r i e r o p e r a t i o n s .

The amendment i s proposed t o i n c o r p o r a t e new environmental t e s t

procedures which were developed t o be more compatible w i t h e x i s t i n g and

a n t i c i p a t e d a i r c r a f t environmental c o n d i t i o n s . These are i n a new FAA

standard r e p l a c i n g RTCA Paper 87-54/D0-57 referenced i n TS0-C35b ( j 514.37).

A change t o the emission o f spurious r a d i o frequency requirement i s the

only change t o the minimum performance standards. Otherwise the FAA standard

i s s i m i l a r t o RTCA Paper 87-54/DO-57.

- 1 -

I n t e r e s t e d persons may p a r t i c i p a t e i n the making of the proposed

r u l e by s u b m i t t i n g such w r i t t e n data, views or arguments as they may d e s i r e .

Communications should be submitted i n d u p l i c a t e to the Docket Section o f the

Federal A v i a t i o n Agency, Room C-226, 1711 New York Avenue, N. W.,

Washington 25, D. C, A l l communications received on or before August 13,

1962, t r i l l be considered by the A d m i n i s t r a t o r before t a k i n g a c t i o n on the

proposed r u l e . The proposals contained i n t h i s n o t i c e may be changed i n

l i g h t o f the comments received. A l l comments submitted w i l l be a v a i l a b l e

i n the Docket Section f o r examination by i n t e r e s t e d persons a t any time.

This amendment i s proposed under the a u t h o r i t y o f Sections 313(a)

and 601 o f the Federal A v i a t i o n Act of 1958 (72 S t a t . 752, 775; 49 U.S.C.

1^54(a), 1421).

I n c o n s i d e r a t i o n o f the foregoing i t i s proposed t o amend P a r t 514

as f o l l o w s :

By r e v i s i n g s e c t i o n 514.37 to read as f o l l o w s :

- 2 -

X 514.37 Radio marker r e c e i v i n g equipment o p e r a t i n g on 75 mc.

( f o r a i r c a r r i e r a i r c r a f t ) - TSO-C35C--(a) A p p l i c a b i l i t y - (1) Minimum

performance standards. Minimum performance standards are hereby e s t a b l i s h e d

f o r a i r b o r n e r a d i o marker r e c e i v i n g equipment o p e r a t i n g on 75 mc. which i s

t o be used on c i v i l a i r c r a f t o f the U n i t e d States engaged i n a i r c a r r i e r

operations. New models o f a i r b o r n e r a d i o marker r e c e i v i n g equipment

o p e r a t i n g on 75 mc. manufactured f o r use on c i v i l a i r c a r r i e r a i r c r a f t on

or a f t e r the e f f e c t i v e date o f t h i s s e c t i o n s h a l l meet the minimum performance

standards contained i n Federal A v i a t i o n Agency Standard e n t i t l e d "Minimum

Performance Standards f o r A i r b o r n e Radio Marker Receiving Equipment Operating

V on 75 mc.", dated A p r i l 6, 1962, and Radio Technical Commission f o r

2/

Aeronautics Paper 120-61/DO-108

- e n t i t l e d , "Environmental Test Procedures

A i r b o r n e E l e c t r o n i c Equipment", dated J u l y 13, 1961, w i t h the exceptions t o

these standards l i s t e d i n subparagraph (2) o f t h i s paragraph.

(2) Exception. Radio Technical Commission f o r Aeronautics Paper

120-61/D0-1Q8 o u t l i n e s v a r i o u s t e s t procedures which d e f i n e the environmental

extremes over which the equipment s h a l l be designed t o operate. Some t e s t

procedures have categories e s t a b l i s h e d and some do not. Where categories

are e s t a b l i s h e d , only equipment which q u a l i f i e s under the f o l l o w i n g c a t e g o r i e s ,

as s p e c i f i e d i n RTCA Paper 120-61/DO-108, i s e l i g i b l e under t h i s order.

( i ) Temperature-Altitude Test - Categories A, B, C, or D.

( i i ) Humidity Test - Categories A or B.

( i i i ) V i b r a t i o n Test - Categories A, B, C, D, E, o r F.

1/Copies may be obtained upon request addressed t o P u b l i s h i n g and Graphics Branch I n q u i r y S e c t i o n , MS-158, Federal A v i a t i o n Agency, Washington 25, D.C.

2/Copies o f t h i s paper may be obtained from the RTCA S e c r e t a r i a t , Room 1072, T-5 B u i l d i n g , 16th & C o n s t i t u t i o n Avenue, N.W. , Washington 25, D.C, a t a cost

of 75 cents per copy.

- 3 -

(iv) A u d i o - F r e q u e n c y M a g n e t i c Field Susceptibility T e s t - C a t e g o r i e s A o r B .

(v) R a d i o - F r e q u e n c y Susceptibility T e s t - Category A .

(vi) Emission of Spurious R a d i o - F r e q u e n c y Energy T e s t - Category A .

(b) M a r k i n g . (1) In a d d i t i o n to the m a r k i n g s specified in 1 514.3 ( d ) ,

the e q u i p m e n t shall be m a r k e d to i n d i c a t e the e n v i r o n m e n t a l extremes o v e r

w h i c h it h a s been d e s i g n e d to o p e r a t e . T h e r e a r e seven e n v i r o n m e n t a l test

p r o c e d u r e s outlined in RTCA P a p e r 120-61/DO-108 which h a v e c a t e g o r i e s

e s t a b l i s h e d . T h e s e should be i d e n t i f i e d on the n a m e p l a t e by the w o r d s

" e n v i r o n m e n t a l c a t e g o r i e s " o r , a s a b b r e v i a t e d , " E n v . C a t . " followed by

seven letters w h i c h identify the c a t e g o r i e s d e s i g n a t e d in RTCA P a p e r

1 2 0 - 6 1 / D O - 1 0 8 . Reading from left to r i g h t , the category d e s i g n a t i o n s shall

a p p e a r on the n a m e p l a t e in the f o l l o w i n g o r d e r so that they m a y b e readily

i d e n t i f i e d :

<i) T e m p e r a t u r e - A l t i t u d e T e s t C a t e g o r y .

(ii) H u m i d i t y T e s t C a t e g o r y .

(iii) V i b r a t i o n T e s t C a t e g o r y .

(iv) A u d i o - F r e q u e n c y M a g n e t i c Field S u s c e p t i b i l i t y T e s t C a t e g o r y .

(v) R a d i o - F r e q u e n c y S u s c e p t i b i l i t y T e s t C a t e g o r y ,

(vi) E m i s s i o n o f Spurious R a d i o - F r e q u e n c y Energy T e s t C a t e g o r y .

(vii) E x p l o s i o n T e s t .

(2) E q u i p m e n t w h i c h m e e t s the e x p l o s i o n test r e q u i r e m e n t shall be

i d e n t i f i e d by the letter " E " , E q u i p m e n t which does n o t m e e t the explosion

test r e q u i r e m e n t shall be i d e n t i f i e d by the letter " X " . A typical n a m e p l a t e

i d e n t i f i c a t i o n w o u l d be as follows: E n v . C a t . D A B A A A X .

- 4 -

( 3 ) I n some c a s e s s u c h a s u n d e r t h e T e m p e r a t u r e - A l t i t u d e T e s t C a t e g o r y , \

a m a n u f a c t u r e r may w i s h t o s u b s t a n t i a t e h i s e q u i p m e n t u n d e r t w o c a t e g o r i e s .

I n t h i s c a s e , t h e n a m e p l a t e s h a l l be m a r k e d w i t h b o t h c a t e g o r i e s i n t h e

s p a c e d e s i g n a t e d f o r t h a t c a t e g o r y by p l a c i n g o n e l e t t e r a b o v e t h e o t h e r

i n t h e f o l l o w i n g m a n n e r : E n v . C a t . j^ABAAAX.

(4) E a c h m a j o r c o m p o n e n t o f e q u i p m e n t ( a n t e n n a , p o w e r s u p p l y , e t c . )

s h a l l be i d e n t i f i e d w i t h a t l e a s t t h e m a n u f a c t u r e r s ' n a m e , TSO n u m b e r , a n d

t h e e n v i r o n m e n t a l c a t e g o r i e s o v e r w h i c h t h e e q u i p m e n t c o m p o n e n t i s d e s i g n e d

t o o p e r a t e .

( c ) D a t a r e q u i r e m e n t s . S i x c o p i e s e a c h of t h e f o l l o w i n g , except where noted, w i t h the statement of conformance t o g e t h e r / s h a l l be f u r n i s h e d t o t h e C h i e f , E n g i n e e r i n g a n d M a n u f a c t u r i n g

B r a n c h , F l i g h t S t a n d a r d s D i v i s i o n , F e d e r a l A v i a t i o n A g e n c y , i n t h e r e g i o n i n

w h i c h t h e m a n u f a c t u r e r i s l o c a t e d :

(1) M a n u f a c t u r e r ' s o p e r a t i n g i n s t r u c t i o n s a n d e q u i p m e n t l i m i t a t i o n s .

(2) I n s t a l l a t i o n p r o c e d u r e s w i t h a p p l i c a b l e s c h e m a t i c d r a w i n g s , w i r i n g

d i a g r a m s , a n d s p e c i f i c a t i o n s . I n d i c a t e a n y l i m i t a t i o n s , r e s t r i c t i o n s , o r

o t h e r c o n d i t i o n s p e r t i n e n t t o i n s t a l l a t i o n .

(3) One c o p y of t h e m a n u f a c t u r e r ' s t e s t r e p o r t .

F l i g h t Standards S e r v i c e

I s s u e d i n Washington, D. C. , on June 19 > 1962.

- 5 -

FEDERAL AVIATION AGENCY

FEDERAL AVIATION AGENCY

WASHINGTON, D.C,

M I N I M U M P E R F O R M A N C E S T A N D A R D S F O R

A I R B O R N E R A D I O M A R K E R R E C E I V I N G E Q U I P M E N T

O P E R A T I N G O N 75 M C .

APRIL: 6, 1962

TABLE OF CONTENTS

Page

INTRODUCTION m

G E N E R A L STANDARDS 1 Rating of Components 1 Operation of Controls 1 Effects of Test 1 R F Gain Control 1 Lamp Actuation (Single Lamp) 1 Lamp Actuation (Three Lamps) 1

INTRODUCTION m

MINIMUM PERFORMANCE STANDARDS UNDER STANDARD T E S T CON- DITIONS 1 Audio Frequency Response 1 Lamp Frequency Response 2 Audio Level Characteristic 2 Rated Audio Power Output 2 Audio Noise Level—Without Signal 2 Audio Noise Level—With Signal 2 Distortion , 2 Output Regulation 2 Emission of Radio Spurious Frequency Energy 2 Sensitivity Depression 2 Input Operating Differential 3 Voltage Standing Wave Ratio 3 Cross Modulation 3 Spurious Response 3 Nose Bandwidth 3 Lamp Operate Selectivity 3 Antenna Polarization 4 Lamp Actuation—Keying 4

MINIMUM PERFORMANCE STANDARDS UNDER ENVIRONMENTAL T E S T CONDITIONS 4 Temperature Altitude Test . 4 Law Temperature Test 4 High Temperature Test 4 Decompression Test 4 Altitude Test 4 Humidity Test 4 Shock Test 4 Vibration Test 5 Temperature Variation Test 5 Low Voltage Test 5 Conducted Voltage Transient Test 5 Conducted Audio Frequency Susceptibility Test 5 Audio Frequency Magnetic Field Susceptibility Test 5 Radio Frequency Susceptibility Test (Radiated and Conducted) 5 Explosion Test - 5

APPENDIX A — T E S T PROCEDURES 7

APPENDIX A — T E S T PROCEDURES 7

Part I—Definitions of Terms and Conditions of Test 9 Power Input Voltage—Direct Current 9 Power Input Voltages—Alternating Current 9

TABLE OF CONTENTS (Continued)

Page

Adjustment of Equipment 9 Test Instrument Precautions 9 Ambient Conditions 9 Warm-Cp Period 9

Connected Loads 9

R F Input Voltage 9

Test Signal Modulation 1 0

Lamp Operate Threshold 10 Receiver Sensitivity Setting 1°

Part II—Detailed Test Procedures 1 1

Part II—Detailed Test Procedures 1 1

T - l Audio Frequency Response H T-2 Lamp Frequency Response H T-3 Audio Level Characteristic H T ^ l Rated Audio Power Output H T-o Audio Noise Level—Without Signal 1 2

T-6 Audio Noise Level—With Signal 1 2

T-7 Distortion *2 T-^S Output Regulation 1 2

T-9 Emission of Spurious Radio Frequency Energy 12 T-10 Sensitivity Depression 13 T - l l Input Operating Differential 13 T-12 Voltage Standing Wave Ratio 13 T-13 Cross Modulation 13 T-14 Spurious Response 14 T-15 Nose Bandwidth I 4

T-16 Lamp Operate Selectivity 1 5

F I G U E E 1—Combining Unit 15

INTRODUCTION

T h i s document sets forth minimum performance standards for airborne

radio marker receiving equipment operating on 75 mc.

Compliance with these standards by manufacturers and users is required

as a means of assuring that the equipment will satisfactorily perform its

intended function.

Inasmuch as the measured values of radio equipment performance char-

acteristics may be a function of the method of measurement, standard test

conditions and methods of test are also included in this document.

T h e word "equipment" as used herein includes all of the components or

units necessary (as determined by the equipment manufacturer) for the

equipment to perform properly its intended function. F o r example, an

airborne radio marker receiving "equipment" may include an antenna, a

receiver unit, a control box, a power supply, a shock mount, etc. I n the

case of this example, all of the foregoing components or units comprise the

"equipment". I t should not be inferred from this example, however, that

every airborne radio marker receiving equipment will necessarily include

all of the foregoing components. T h i s will depend on the design used by

the equipment manufacturer.

r n

M I N I M U M P E R F O R M A N C E S T A N D A R D S F O R

A I R B O R N E R A D I O M A R K E R R E C E I V I N G E Q U I P M E N T

O P E R A T I N G O N 75 M C .

1.0 GENERAL STANDARDS

1.0 GENERAL STANDARDS

1.1 Rating of Components

The equipment shall not incorporate in its design any components of such rating that, when the equipment is operated throughout the range of the specified environmental tests, the rating established by the manufacturer of the component is exceeded. For electron tubes, the continuous commercial service rating of the tube manufacturer is applicable except for the heaters and filaments. The voltage applied to the heaters and filaments of electron tubes shall be within 5 % of the manufacturer's rating when the equipment is operated under standard operating conditions. When the heaters and filaments are connected in series, the 5% tolerance shall apply to the sum of their voltage ratings.

1.2 Operation of Controls

1.2 Operation of Controls

The design of the equipment shall be such that the controls intended for use during flight cannot be operated in any possible position combination of sequence which would result in a condition whose presence or continuation would be detrimental to the reliability of the equipment.

1.3 Effects of Test

1.3 Effects of Test

Unless otherwise provided, the design of the equipment shall be such that, subsequent to the application of the specified tests, no discernible condition exists which would be detrimental to the continued performance of the equipment.

1.4 RF Gain Control

Means shall be provided for so fixing the adjustment of receiver sensitivity that,

1.4 RF Gain Control

when flying over a Z marker at 1000 feet

above ground at 120 mph ground speed, a light "on" time between 12 and 15 seconds is obtained. The fixed sensitivity adjustment control shall not be readily variable by flight personnel. When the equipment is designed for in-flight control of receiver sensitivity, the in-flight controls shall not be capable of adjusting the receiver sensitivity below the fixed setting level.

1.5 Lamp Actuation (Single Lamp)

1.5 Lamp Actuation (Single Lamp)

In the case of equipment designed to operate a single lamp, the lamp shall be actuated by each of the three modulation frequencies.

1.6 Lamp Actuation (Three Lamps)

In the case of equipment designed to operate a separate lamp for each of the three modulation frequencies, the 400 cps tone shall actuate the blue light, the 1300 cps tone the amber light, and the 3000 cps tone the white light.

2.0 MINIMUM PERFORMANCE STANDARDS UNDER STANDARD TEST CONDITIONS

2.0 MINIMUM PERFORMANCE STANDARDS UNDER STANDARD TEST CONDITIONS

The test procedures, applicable to a determination of the performance of airborne 75 Mc radio marker receiving equipment under standard test conditions, are

set forth in Appendix " A " of this report.

2.1 Audio Frequency Response

2.1 Audio Frequency Response

The total spread in audio output of the receiver shall not exceed 9 db when the frequency of the modulation on the input signal is varied over the combined ranges of 380 to 420 cps, 1235 to 1365 cps, and 2850 to 3150 cps. The rf level of the input signal shall be ten times that producing lamp operate threshold at 1300 cps.

2.2 Lamp Frequency Response

2.2 Lamp Frequency Response

The variation in r f input level required to produce lamp operate threshold shall not exceed 9 db when the frequency of the modulation on the input signal is varied over the combined ranges of 380 to 420 cps,

1235 to 1365 cps, and 2850 to 3150 cps.

2.3 Audio Level Characteristic

2.3 Audio Level Characteristic

The receiver audio output at each of the modulation frequencies of 400, 1300, and 3000 cps shall not vary more than 10 db when the level of the r f input signal is varied over the range from that producing lamp operate threshold to 200.000 /iv.

2.4 Rated Audio Power Output

The audio output power of the receiver shall be not less than the rated output when an r f signal having a level ten times that producing lamp operate threshold at 1300 cps is applied to the receiver input.

2.5 Audio Noise Level—Without Signal

2.5 Audio Noise Level—Without Signal

a. The level of the noise output of the

receiver, in the absence of an r f input signal, shall be at least 35 db below the output obtained with an r f input signal having a level ten times that

producing lamp operate threshold.

b. The level of the output at discrete

audio frequencies, in the absence of an r f input signal, shall be at least 40 db below the output obtained with an r f input signal having a level ten times that producing lamp operate

threshold. Equipment designed for an A C power source shall meet this requirement at all power frequencies

within the range for which the equipment is designed.

2.6 Audio Noise Level—With Signal

2.6 Audio Noise Level—With Signal

a. The receiver output signal plus noiseto-noise ratio shall be at least 20 db over the range of r f input signal level from that producing lamp operate threshold to 200,000 hv. b. The level of the receiver output at

discrete audio frequencies shall be at least 30 db below the signal plus noise output over the range of r f input

signal level from that producing lamp operate threshold to 200,000 /xv. Equipment designed for an A C power source shall meet this requirement at all power frequencies within the range for which the equipment is designed.

2.7 Distortion

2.7 Distortion

Over the range of r f signal input level from that producing lamp operate threshold to 200,000 p.v, the combined noise and distortion in the equipment output shall not exceed 30% of the total output.

2.8 Output Regulation

W i t h an output load of 200% of design impedance and with an output load of 50% of design impedance, the distortion in the output shall not exceed 30%, and the output voltage level shall be within 2 : 1 of the level when the load is that for which

2.8 Output Regulation

the receiver is designed.

2.9 Emission of Spurious Radio Frequency Energy

The levels of conducted and radiated spurious radio frequency energy emitted by the equipment shall not exceed those levels specified in Appendix A of R T C A Paper 120-61/DO-108—"Environmental Test Procedures—Airborne Electronic Equipment", dated July 13,1961, for the aircraft category for which the equipment is designed.

2.10 Sensitivity Depression

2.10 Sensitivity Depression

a. The level of the r f input signal at 75

Mc, required to produce lamp oper-

ate threshold, shall not increase more than 4 db when there is added to the receiver input channels 4 and5 television signals having a level of 3.5 v. b. The level of the r f input signal at 75

Mc, required to produce lamp oper-

ate threshold, shall not increase more than 4 db when there is added to the receiver input a .5 v r f signal frequency modulated 1300 cps at a devi-

ation of ±15 kc. This standard shall be met over the F M signal frequency ranges of 72.02-74.58 Mc and 75.42- 75.98 Mc.

2.11 Input Operating Differential

2.11 Input Operating Differential

T h e r a t i o o f the r f i n p u t signal level

required t o produce l a m p operate thresh-

o l d when the r f i n p u t signal level is i n -

creasing to the r f i n p u t signal level re-

q u i r e d t o produce l a m p operate threshold

when the r f i n p u t signal level is decreas-

i n g shall not exceed 2 : 1 .

2.12 Voltage Standing Wave Ratio

2.12 Voltage Standing Wave Ratio

W h e n the receiver is designed f o r use

w i t h an antenna transmission line, the

voltage s t a n d i n g wave r a t i o produced on

the transmission line h a v i n g a characteris-

t i c impedance f o r w h i c h the receiver i n p u t

c i r c u i t is designed shall not exceed a value

o f 2 to 1 when the transmission line is

connected to the receiver i n p u t a n d a 75 M c

signal is f e d to the receiver t h r o u g h the

transmission line.

2.13 Cross Modulation

2.13 Cross Modulation

a. T h e voltage across t h e i n d i c a t o r

l a m p ( s ) due t o cross m o d u l a t i o n shall

not exceed the voltage at l a m p oper-

ate threshold nor shall the audio out-

p u t exceed one-half t h e manufac-

turer's r a t e d o u t p u t when there are

a p p l i e d simultaneously to the receiver

i n p u t an u n m o d u l a t e d carrier at cen-

ter response frequency h a v i n g a level

equal to t h a t o f a signal p r o d u c i n g

l a m p operate threshold a n d a tele-

vision signal h a v i n g a level o f 3.5 v.

T h i s standard shall be met at the

television signal frequencies o f chan-

nels 2 t h r o u g h 6.

b. T h e voltage across t h e i n d i c a t o r

l a m p { s ) due to cross m o d u l a t i o n shall

not exceed the voltage at l a m p oper-

ate threshold nor shall t h e audio out-

p u t exceed one-half the manufac-

t u r e r ' s r a t e d o u t p u t when there are

a p p l i e d simultaneously t o the receiver

i n p u t an u n m o d u l a t e d carrier at cen-

ter response frequency h a v i n g a level

equal t o t h a t o f a signal p r o d u c i n g

l a m p operate threshold a n d a .5 v r f

signal frequency m o d u l a t e d 1300 cps

at a deviation o f ± 1 5 kc. T h i s

standard shall be met over the F M

signal frequency ranges o f 72.02-74.58

M c and 75.42-75.98 M c .

2.14 Spurious Response

2.14 Spurious Response

a. T h e voltage across the indicator

l a m p ( s ) shall n o t exceed the l a m p operate threshold voltage nor shall

the audio o u t p u t exceed one-half t h e

manufacturer's rated o u t p u t w h e n an

r f i n p u t signal o f 0.5 v, a m p l i t u d e

modulated 3 0 % i n t u r n at 400, 1300,

and 3000 cps, is v a r i e d over the f r e - quency range o f .190 M c to 1500 M c ,

excluding the band f r o m 65 to 85 M c .

b. T h e voltage across the i n d i c a t o r

l a m p ( s ) shall not exceed the l a m p operate threshold voltage nor shall

the audio o u t p u t exceed one-half the

manufacturer's r a t e d o u t p u t when an

r f i n p u t signal o f .5 v, frequency

modulated i n t u r n at 400, 1300, a n d 3000 cps at a deviation o f ± 1 5 kc, is

varied over the frequency ranges o f 72.02-74.58 M c and 75.42-75.98 M c .

c. T h e voltage across t h e indicator

l a m p ( s ) shall not exceed the l a m p operate threshold voltage nor shall

the audio o u t p u t exceed one-half the

manufacturer's r a t e d o u t p u t w h e n an

r f i n p u t signal o f 3.5 v w i t h tele-

vision signal m o d u l a t i o n is applied

at television signal frequencies o f

channels 2 t h r o u g h 6.

2.15 Nose Bandwidth

2.15 Nose Bandwidth

T h e level of the i n p u t signal required to produce l a m p operate threshold over the

i n p u t signal frequency range o f 75 M e —10

kc t o 75 M c + 1 0 kc shall not be more t h a n

6 db above the i n p u t required to produce

l a m p operate t h r e s h o l d at the frequency o f

m a x i m u m response.

2.16 Lamp Operate Selectivity

2.16 Lamp Operate Selectivity

I n the case of equipment designed to

operate a separate l a m p f o r each o f the

three m o d u l a t i o n frequencies o f 400, 1300

a n d 3000 cps, the voltage across t h e t w o

lamps not intended to be operated shall be less t h a n 3 0 % o f rated l a m p voltage over

the i n p u t signal range f r o m t h a t p r o d u c i n g

l a m p operate threshold to 200,000 av.

2.17 Antenna Polarization

2.17 Antenna Polarization

T h e antenna to be used on the aircraft

shall be designed so as to produce, when

installed according to the manufacturer's

instructions, a maximum response from 75

M c signals radiated from below the air-

craft with the received electric field com-

ponent parallel to the line of flight.

2.18 Lamp Actuation—Keying

2.18 Lamp Actuation—Keying

T h e variation i n intensity of the light

from the lamps shall indicate the keying

of the modulation of the input signal.

T h e modulation of the input signal shall

be keyed at the rate of s i s dots per second,

and the modulation O X time to modulation

O F F time ratio shall be 1:1.

3.0 MINIMUM PERFORMANCE STANDARDS UNDER ENVIRONMENTAL TEST CONDITIONS

3.0 MINIMUM PERFORMANCE STANDARDS UNDER ENVIRONMENTAL TEST CONDITIONS

Unless otherwise specified, the test pro-

cedures applicable to a determination of

the performance of this equipment under

environmental test conditions are set forth

in R T C A Paper 120-61/DO-108 " E n v i -

ronmental Test Procedures — Airborne

Electronic E q u i p m e n t " dated J u l y 13,1961.

3.1 Temperature—Altitude Test

3.1 Temperature—Altitude Test

3.1.1 Low Temperature Test

When the equipment is subjected to this

test:

a. T h e r f input required to produce

lamp operate threshold shall be

within 6 db of that required under

standard operating conditions.

b. T h e audio output with an input sig-

3.1.1 Low Temperature Test

nal having a level of ten times that

producing lamp operate threshold

shall be within 6 db of the output

obtained under standard operating

conditions.

3.1.2 High Temperature Test a. W h e n the equipment is operated at

the H i g h Short-Time Operating

Temperature:

(1) A l l mechanical devices shall op-

erate satisfactorily.

(2) There shall be no evidence of ma-

terials, such as grease or potting

and sealing compounds, exuding

or dripping from the equipment.

b. W h e n the equipment is operated at

the H i g h Operating Temperature the

audio output with an input signal

having a level of ten times that pro-

ducing lamp operate threshold shall

be within 6 db of the output obtained

under standard operating conditions.

3.1.3 Decompression Test (When Required}

3.1.3 Decompression Test (When Required}

W h e n the equipment is subjected to this

test the performance requirements of para-

graphs 2.3 and 2.4 shall be met.

3.1.4 Altitude Test

W h e n the equipment is subjected to the

altitude test, the performance requirements

of paragraphs 2.3 and 2.4 shall be met.

3.2 Humidity Test

3.2 Humidity Test

a. After being subjected to humidity

and within 15 minutes after primary

power is applied, the lamp operate

sensitivity shall be within 4 : 1 of

that obtained under standard oper-

ating conditions. T h e audio output

shall be within 6 db of that obtained

under standard operating conditions

when the r f signal input level i n each

case is ten times that producing lamp

operate threshold under standard

operating conditions.

b. W i t h i n four hours from the time p r i -

mary power is applied, the lamp op-

erate sensitivity shall be within 2 db

of that obtained under standard op-

erating conditions. T h e audio out-

put shall be within 2 db of that ob-

tained under standard operating con-

ditions when the r f signal level in

each case is ten times that producing

lamp operate threshold under stand-

ard operating conditions.

3.3 Shock Test

3.3 Shock Test

a. Following the application of the

Operational Shocks, the lamp oper-

ate sensitivity shall be within 2 db of

that obtained under standard oper-

ating conditions. T h e audio output

shall be within 2 db of that obtained

under standard operating conditions

when the r f signal level i n each case

is ten times that producing lamp op-

erate threshold under standard oper-

ating conditions.

b. F o l l o w i n g the application of the

C r a s h Safety Shocks, the equipment

under test shall have remained i n its

mounting, and no parts of the equip-

ment or its mounting shall have

become detached and free of the

equipment. P a r a g r a p h 1.3 does not

apply. 1

3.4 Vibration Test

3.4 Vibration Test

W h e n subjected to this test, the stand-

ards of paragraphs 2.5(a) and 2.6(a) shall

be met. T h e level of the input signal

required to produce lamp operate threshold

shall be within 2 db of that required under

standard operating conditions.

3.5 Temperature Variation Test

3.5 Temperature Variation Test

W h e n the equipment is subjected to this

test, the standards of paragraph 2.15 shall

be met.

3.6 Low Voltage Test

a. W h e n the primary power voltage (s)

of D C operated equipment i s 8 0 %

and when that of A C operated equip-

ment is 87*4% of standard test volt-

age ( s ) , the equipment shall start and

3.6 Low Voltage Test

continue to operate electrically and

mechanically. Degradation of per-

formance is tolerable.

b. D C operated equipment shall operate

satisfactorily within two (2) minutes

upon returning the p r i m a r y power

voltage (s) to normal after the grad-

ual reduction of the primary power

1 T h e a p p l i c a t i o n o f t h i s t e s t a n d t h a t r e q u i r e d b y p a r a g r a p h

3 . 6 ( c ) m a y r e s u l t I n d a m a g e t o t h e e q u i p m e n t u n d e r t e s t .

T h e r e f o r e , t h e y m a y b e c o n d u c t e d a f t e r t h e o t h e r t e s t s a r e

c o m p l e t e d . P a r a g r a p h 1.3 d o e s n o t a p p l y .

voltage(s) from 8 0 % to 5 0 % of

standard test voltage(s).

c. T h e gradual reduction of the primary

power voltage (s) of D C operated

equipment from 5 0 % to 0 % of stand-

ard test voltage(s) shall produce no

evidence of the presence of fire or

smoke. 2

3.7 Conducted Voltage Transient Test

3.7 Conducted Voltage Transient Test

a. F o l l o w i n g the Intermittent Transient

Test, the performance requirements

of paragraph 2,4 shall be met.

b. D u r i n g the Repetitive Transients

Tests, the performance requirements

of paragraphs 2.5 and 2.6 shall be

met.

3.8 Conducted Audio-Frequency Susceptibility

3.8 Conducted Audio-Frequency Susceptibility

Test

W h e n the equipment is subjected to this

test, the performance requirements of par-

agraphs 2.5 and 2.6 shall be met.

3.9 Audio-Frequency Magnetic Field Susceptibility Test

W h e n the equipment is subjected to this

test, the performance standards of para-

graphs 2.5 and 2.6 shall be met.

3.10 Radio-Frequency Susceptibility Test

3.10 Radio-Frequency Susceptibility Test

(Radiated and Conducted!

W h e n the equipment is subjected to this

test, the performance requirements of para-

graphs 2.4 and 2.7 shall be met, excepting

within the band of ± 1 0 0 k c of 75 Mc.

3.11 Explosion Test {When Required)

D u r i n g the application of this test, the

3.11 Explosion Test {When Required)

equipment shall not cause detonation of

the explosive mixture within the test

chamber.

3 T h e a p p l i c a t i o n o f t h i s t e s t a n d t h a t r e q u i r e d b y p a r a g r a p h

3 . 3 ( 6 ) m a y r e s u l t i n d a m a g e to t h e e q u i p m e n t u n d e r t e s t .

T h e r e f o r e , t h e y m a y be c o n d u c t e d a f t e r t h e o t h e r t e s t s a r e

c o m p l e t e d . P a r a g r a p h 1.3 d o e s n o t a p p l y .

APPENDIX A

APPENDIX A

TEST P R O C E D U R E S

A I R B O R N E R A D I O M A R K E R R E C E I V I N G E Q U I P M E N T

O P E R A T I N G O N 7 5 M C .

NOTE

T H E T E S T P R O C E D U R E S S E T F O R T H I N P A R T I I O F T H I S

A P P E N D I X A R E S A T I S F A C T O R Y F O R U S E I N D E T E R M I N I N G

TEST P R O C E D U R E S

T H E P E R F O R M A N C E O F A I R B O R N E R A D I O M A R K E R R E C E I V -

I N G E Q U I P M E N T O P E R A T I N G O N 75 M C . TEST PROCEDURES

WHICH PROVIDE EQUIVALENT INFORMATION MAY BE USED.

PART I

D E F I N I T I O N S O F T E R M S A N D C O N D I T I O N S O F T E S T

PART I

T h e following definitions of terms and condi-

tions of test are applicable to the equipment tests

specified herein:

a. Power Input Voltage—Direct Current

Unless otherwise specified, when the re-

ceiver is designed for operation from a d i -

rect current power source, all measurements

shall be conducted with the power input

voltage adjusted to 13.75 v, ± 2 % for 12-14 v

equipment, or to 27.5 v, ± 2 % for 24-28 v

equipment. T h e input voltage shall be

measured at the receiver power input ter-

minals.

b. Power Input Voltage—Alternating Current

Unless otherwise specified, when the re-

ceiver is designed for operation from an

alternating current power source, all tests

shall be conducted with the power input

voltage adjusted to design voltage ± 2 % .

I n the case of receivers designed for opera-

tion from a power source of essentially con-

stant frequency (e.g, 400 c p s ) , the input fre-

quency shall be adjusted to design fre-

quency ± 2 % . I n the case of receivers de-

signed for operation from a power source of

variable frequency (e.g., 350 to 1000 c p s ) ,

tests shall be conducted with the input fre-

quency adjusted to within 5 % of a selected

frequency within the range for which the

equipment is designed.

c. Adjustment of Equipment

T h e circuits of the receiver shall be prop-

erly aligned and otherwise adjusted i n ac-

cordance with the manufacturer's recom-

mended practices prior to the application of

the specified tests.

d. Test Instrument Precautions

D u e precautions shall be taken to prevent

the introduction of errors resulting from

the connection of headphones, voltmeters,

oscilloscopes, and other test instruments

across the input and output impedances of

the receiver during the conduct of the tests.

e. Ambient Conditions

Unless otherwise specified, all tests shall

be conducted under conditions of ambient

room temperature, pressure, and humidity.

However, the room temperature shall not be

lower than 10° C .

f. Warm-up Period

Unless otherwise specified, a l l tests shall

be conducted after a warm-up period of not

less than fifteen (15) minutes.

g. Connected Loads

Unless otherwise specified, a l l tests shall

be performed with the receiver outputs con-

nected to loads having the impedance value

for which the receiver is designed.

h. RF Input Voltage

T h e " r f input voltage" is defined as the

"open circuit" voltage of the circuit con-

nected to the receiver input. T h e circuit

connected to the receiver input shall be the

equivalent of the r f input voltage in series

with an impedance having a resistance

within 1 0 % and a reactance of not more

than 1 0 % of the characteristic impedance of

the transmission line for which the receiver

is designed.

N O T E : The rf input voltages specified herein are

for the case of a receiver designed for a transmission line having a nominal characteristic impedance of 52 ohms. In the case of a receiver designed for a transmission line having a nominal characteristic Impedance of other than 52 ohms, the rf input voltage values shall be computed accord-

ing to the following equation:

E 2 = \/E,

2

52

Where E , is the rf input voltage to be used

in the case of a receiver designed for a transmission line having a nominal characteristic impedance other than 52 ohms— E j is the rf input voltage specified

herein— Rj is the nonunal characteristic im-

pedance of the transmission line for which the receiver is designed.

Test Signal Modulation

Unless otherwise specified, the r f input

signal shall be a 75 Mc ± . 0 0 5 % signal am-

plitude modulated 9 5 % successively at 400

± 1 % cps, 1300 ± 1 % cps, and 3000 ± 1 %

cps.

j . Lamp Operate Threshold

T h e term " l a m p operate threshold", as

used herein, is defined as that condition

wherein an increase of 5 % or less in r f input

signal voltage results in lighting of the indi-

cator lamp. I n the case of receivers in

which the voltage across the indicator

lamp(s) varies with the signal input, the

lamp(s) is considered lit when the voltage

appearing across the lamp terminals is one-

half or more of its average rated voltage.

k. Receiver Sensitivity Setting

Unless otherwise specified, the receiver

gain shall be adjusted to produce lamp oper-

ate threshold with an r f input signal level

of 2000 y*V.

PART II

PART II

DETAILED TEST

T - l A U D I O F R E Q U E N C Y R E S P O N S E Equipment Required

R F S i g n a l Generator (Hewlett Pack-

ard Model 608B or equivalent).

A F Signal Generator (Hewlett P a c k -

ard Model 200B or equivalent).

Audio Output Meter (General Radio

Model 583A or equivalent).

DETAILED TEST

Voltmeter of suitable impedance and

range ( i f required) for determining

lamp operate threshold. Measurement Procedure

A p p l y to the receiver input an r f sig-

nal having a level ten times that produc-

ing lamp operate threshold at 1300 cps

and measure the audio output over the

input signal modulation frequency

ranges of 380-420 cps, 1235-1365 cps,

and 2850-3150 cps.

T-2 L A M P F R E Q U E N C Y R E S P O N S E Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

A F Signal Generator (Hewlett P a c k -

ard Model 200B or equivalent).

Voltmeter, i f required, of suitable im-

pedance and range for determining lamp

operate threshold.

Measurement P r o c e d u r e

A p p l y to the receiver input a n r f sig-

nal amplitude modulated 9 5 % at each

of the following frequencies: 380, 400, 420,1235,1300,1365, 2850,3000, and 3150

cps. F o r each modulation frequency,

determine the level of the input signal

required to produce lamp operate thresh-

old. Compute the difference i n db be-

tween the maximum and minimum input

signal levels.

PROCEDURES

T-3 A U D I O L E V E L C H A R A C T E R I S T I C Equipment Required

R F S i g n a l Generator (Hewlett P a c k -

ard Model 608B or equivalent).

A F Signal Generator (Hewlett P a c k -

ard Model 200B or equivalent).

Audio Output Meter (General Radio

Model 583A or equivalent).

Voltmeter of suitable impedance and

range ( i f required) for determining

lamp operate threshold.

M e a s u r e m e n t Procedure

A p p l y an r f signal to the receiver

input and measure the audio output at

each of the modulation frequencies of

400, 1300, and 3000 cps over the r f sig-

nal input level range from that produc-

ing lamp operate threshold to 200,000 ^v.

Determine the difference in db between

the maximum and minimum output

levels.

T-4 R A T E D A U D I O P O W E R O U T P U T

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

A F Signal Generator (Hewlett P a c k -

ard Model 200B or equivalent).

Audio Output Meter (General Radio

Model 583A or equivalent).

Voltmeter of suitable impedance and

range, i f required, for determining lamp

operate threshold.

M e a s u r e m e n t P r o c e d u r e

A p p l y to the receiver input an r f sig-

nal having a level ten times that produc-

ing lamp operate threshold at 1300 cps.

Determine the audio power output at

the modulation frequencies of 400, 1300,

and 3000 cps.

AUDIO NOISE LEVEL—WITHOUT SIGNAL

AUDIO NOISE LEVEL—WITHOUT SIGNAL

Equipment Required

Resistance having a value equal to the

impedance for which the receiver output

is designed.

V a c u u m Tube Voltmeter (Ballantine

Model 300 or equivalent).

W a v e Analyzer (General Radio Model

736A or equivalent).

Measurement Procedure

Connect to the receiver input an i m -

pedance equal to that for which the re-

ceiver is designed. Measure (a) the

wide band audio noise output and (b)

the output at discrete frequencies over

the range of 50 to 10,000 cps.

I n the case of receivers designed for

an A C power source, detennine the max-

imum audio output over the range of

input power frequency for which the

equipment is designed.

AUDIO NOISE LEVEL—WITH SIGNAL

AUDIO NOISE LEVEL—WITH SIGNAL

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Audio Output Meter (General Radio

Model 583A or equivalent).

W a v e Analyzer (General Radio Model

736A or equivalent).

Measurement Procedure

A p p l y to the receiver input an r f sig-

nal.

a. Determine the minimum signal

plus noise-to-noise ratio over the

range of input signal level from

that producing lamp operate

threshold to 200,000 / i v .

b. Remove the modulation from the

input signal and determine the

maximum output at discrete fre-

quencies over the range of 50 to

10,000 cps when the input signal

level is varied over the range from

that producing lamp operate

threshold to 200,000 p.v.

I n the case of receivers designed for

an A C power source, make the above

determinations over the combined ranges

of signal input level from that produc-

ing lamp operate threshold to 200,000 j*v

and input power frequency for which (

the receiver is designed.

T-7 DISTORTION

T-7 DISTORTION

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Distortion and Noise Meter ( R C A

69B or equivalent).

Measurement Procedure

A p p l y to the receiver input an r f sig-

nal. Determine the maximum percent-

age of distortion plus noise at 400, 1300,

and 3000 cps at a n input signal level

producing lamp operate threshold at 1300 cps and at an input signal level ten

times that producing lamp operate

threshold at 1300 cps.

T-8 OUTPUT REGULATION

T-8 OUTPUT REGULATION

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Distortion and Noise Meter ( R C A

Model 69B or equivalent).

Output load resistors having values

equal to 5 0 % , 100%, and 2 0 0 % of the

output load impedance for which the

receiver is designed.

Measurement Procedure

A p p l y to the receiver input a n r f sig-

nal having a level ten times that pro-

ducing lamp operate threshold at 1300

cps. Determine, at the modulation fre-

quencies of 400, 1300, and 3000 cps, the

percentage of distortion plus noise in the

audio output and the audio output volt-

age level with output loads equal to 5 0 % ,

100%, and 2 0 0 % of that for which the

receiver is designed.

T-9 EMISSION OF SPURIOUS RADIO

T-9 EMISSION OF SPURIOUS RADIO

FREQUENCY ENERGY

Equipment Required

See Paragraphs 1 and 2, Page 3 of

Appendix A of P a p e r 120-61/DO-108.

Measurement Procedure

See P a r a g r a p h 3, Page 5 of Appen-

dix A .

12

T-10 SENSITIVITY DEPRESSION

Equipment Required

A Combining U n i t as shown in F i g -

T-10 SENSITIVITY DEPRESSION

ure 1.

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Frequency modulated signal genera-

tor.

Television signal amplifier capable of

boosting the level of a T V signal to at

least 3.5 v peak. T h e frequency re-

sponse characteristic of the amplifier

shall be within 3 db over the frequency

range from —.5 M c to +4 M c of the

video carrier frequency. F o r the pur-

pose of this test, a signal simulating that

of a T V signal may be used. Such sim-

ulated T V signal shall be a 3.5 v peak r f

signal pulse modulated at a rate of 60

pps. T h e pulse duration shall be 800 to

1000 jus, and the rise and decay time

shall not exceed .08 /ts.

/Weasuremenf Procedure

Connect the two signal generators (or

the amplitude modulated signal gener-

ator and the television signal amplifier)

as shown in F i g u r e 1.

A p p l y a 75 M c desired signal modu-

lated 1300 cps. A d j u s t the signal input

level to produce lamp operate threshold.

A p p l y , successively, a television signal

having a level of 3.5 v and an F M signal

modulated 1300 cps at a deviation of

± 1 5 k c and having a level of .5 v and

determine the db increase i n level of the

desired signal required to produce lamp

operate threshold. Conduct this test at

television channel frequencies 4 and 5 i n

the case of the television signal and at

74.6 M c and 75.4 M c in the case of the

F M modulated signal.

T-11 INPUT OPERATING DIFFERENTIAL

T-11 INPUT OPERATING DIFFERENTIAL

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Measurement Procedure

A p p l y to the receiver input an r f sig-

nal. Determine the ratio i n db of the

r f input signal level required to produce

lamp operate threshold when the input

signal level is slowly increasing to the

r f input signal level required to produce

lamp operate threshold when the input

signal level is slowly decreasing.

T-12 VOLTAGE STANDING WAVE RATIO

T-12 VOLTAGE STANDING WAVE RATIO

Equipment Required

R F Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

Slotted line or impedance bridge.

Measurement Procedure

a. W h e n the slotted line is used:

Connect the slotted line between

the receiver input and the signal

generator. T u r n the receiver on

and operate it normally. Set the

level of the input signal below the

level which overloads the receiver

input circuit. Measure the maxi-

mum and minimum voltages along

the slotted line and calculate the

V S W R using the following equa-

tion:

V S W R - ^ a X ' m U m T ° ^ t a £ e Minimum voltage

along the slotted line

along the slotted line b. When the impedance bridge is

used, measure the impedance of the

input circuit and compute the

V S W R .

T-13 CROSS MODULATION

T-13 CROSS MODULATION

Equipment Required

A M Signal Generator (Hewlett P a c k -

ard Model 608B or equivalent).

F M signal generator.

Television signal amplifier capable of

boosting the level of a T V signal to at

least 3.5 v peak. T h e frequency re-

sponse characteristic of the amplifier

shall be within 3 db over the range from

— .5 M c to + 4 M c of the video carrier

frequency. F o r the purpose of this test,

a simulated T V signal may be used.

S u c h simulated T V signal shall be an r f

signal pulse modulated at a rate of 60

pps. T h e pulse duration shall be 800 to

1000 ^s, and the rise and decay time shall

not exceed .08 fis.

A Combining Unit as shown in F i g -

ure 1.

Audio Output Meter (General Radio

Model 583A or equivalent).

Measurement Procedure

Connect the two signal generators to-

gether by means of the •"Combining

U n i t " as shown in Figure 1.

A p p l y to the receiver input a 75 Mc

desired signal modulated 1300 cps. A d -

just the signal input level to produce

lamp operate threshold. Remove the

modulation from the desired carrier.

Apply, successively, a television signal

having a level of 3.5 v and an F M signal

modulated 1300 cps at a deviation of

± 1 5 kc and having a level of .5 v and

determine whether the lamp voltage ex-

ceeds lamp operate threshold voltage

and whether the audio output exceeds

one-half the manufacturer's rated out-

put. Conduct this test at television

channel frequencies 2 through 6 in the

case of the television signal and over the

ranges of 72.02-74.58 M c and 75.42-75.93

M c in the case of the F M signal.

N O T E : At each setting, determine whether the

output is due to cross modulation or to direct demodulation of the undesired signal. Make this determination by turning off the desired carrier and noting audio output. If tbe output drops, ( T O S S modulation has been encountered, and the data should be recorded. If the output does not drop, the undesired signal is at a spurious

response frequency, and the data should not be recorded.

FURIOUS RESPONSE

FURIOUS RESPONSE

Equipment Required

A M signal generators to cover the

band from .190 M c to 1500 Mc.

Audio Output Meter (General Radio

Model 583A or equivalent).

Voltmeter, i f required, of suitable i m -

pedance and range for determining lamp

operate threshold.

F M signal generator.

Television signal amplifier capable of

boosting the level of a T V signal to at

least 3.5 v peak. T h e frequency re-

sponse characteristic of the amplifier

shall be within 3 db over the range from

— .5 M c to + 4 M c of the video carrier

frequency. F o r the purpose of this test,

a simulated T V signal may he used.

S u c h simulated T V signal shall be a n r f

signal pulse modulated at a rate of 60

pps. T h e pulse duration shall be 800 to

1000 fts, and the rise and decay time shall

not exceed .08 us.

Measurement Procedure

Determine whether the voltage across

the indicator l a m p ( s ) exceeds lamp op-

erate threshold or the audio output ex-

ceeds one-half rated output w h e n :

a. T h e r f input signal has a level of

.5 v is amplitude modulated 3 0 %

successively at 400, 1300, and 3000

cps, and its radio-frequency is

varied over the range from .190 M c

to 1500 M c , excluding the band 65

M c to 85 Mc.

b. T h e r f input signal is a television

signal having a level of 3.5 v and

frequencies of television channels

2 through 6.

c. T h e r f input signal has a level of

.5 v, is frequency modulated suc-

cessively at 400,1300, and 3000 cps,

and its center frequency is varied

over the range of 65 M c to 85 M c ,

excluding the band 74.6 M c to

75.4 M c .

T - l 5 NOSE BANDWIDTH

T - l 5 NOSE BANDWIDTH

Equipment Required

Signal Generator (Hewlett P a c k a r d

Model 608B or equivalent).

Voltmeter, i f required, of suitable im-

pedance and range for determining lamp

operate threshold.

Measurement Procedure

A p p l y to the receiver input a n r f sig-

nal and determine the signal level re-

quired to produce lamp operate thresh-

old over the r f signal frequency range

from 75 M c - 1 0 k c to 75 M c + 1 0 kc.

T - 1 6 L A M P O P E R A T E S E L E C T I V I T Y

(Applies only to receivers designed to

operate a separate lamp for each modula-

tion frequency.)

Equipment Required

R F S i g n a l Generator (Hewlett P a c k -

ard Model 608B or equivalent).

A F Signal Generator (Hewlett P a c k -

ard Model 200B or equivalent).

Voltmeter of suitable impedance and

range for determining the voltage across

the indicator lamps or the relay coils. Measurement Procedure

A p p l y to the receiver input an r f sig-

nal. Determine the voltage across the

indicator lamps not intended to be lit

over the r f input signal range from that

producing lamp operate threshold to

200,000 /tv.

Desired Signal

R/2

To Receiver

Undesired

Signal

-o

characteristic impedance of the transmission line for which the receiver i s designed*

F I G U R E 1—Combining Unit.