CAR 63 Notice No. 63-31 Technical Standard Orders. Life Preserves - TSO-C13d
Text re-read from the scan: 20 of 20 passages.
- Date
- Nov 21, 2026
- Recorded
- Nov 21, 2026
- Passages
- 20 of 20 changed
- Paragraphs
- 43 added or rewritten, 117 removed or rewritten
Read the current text Official source ↗
What changed in the text
Key: [removed: removed words] are struck through; [added: added words] are underlined. Each changed paragraph is labelled in the margin.
FEDERAL AVIATION AGENCY
FLIGHT STANDARDS SERVICE
- Removed
[removed: [14 CFR 514] [Regulatory Docket No. lRD2; Kotice Ko. 63~31]] - Added
[added: [14 CFR 514]]
- Removed
[removed: TECHNICAL STANDARD ORDERS FOR AIRCRAFT MATERIALS,] - Added
[added: [Regulatory Docket No. 1892; Notice No. 63–31]]
- Removed
[removed: PARTS AND APPLIANCES] - Added
[added: TECHNICAL STANDARD ORDERS FOR AIRCRAFT MATERIALS, PARTS AND APPLIANCES]
NOTICE OF PROPOSED RULE MAKING
- Changed
Life
[removed: Preservers-TSO-C13d][added: Preservers—TSO-C13d] - Removed
[removed: The Federal Aviation Agency has under consideration II pJ"Opmml to revif'e Section fiH.2R of Part 514 of the Hegnlations of the Administrator by amend-] - Added
[added: The Federal Aviation Agency has under considera- this notice may be changed in the light of comments tion a proposal to revise Section 514.23 of Part 514 received. All comments submitted will be available, of the Regulations of the Administrator by amend- both before and after the closing date for comments, ing the Technical Standard Order. This Technical in the Rules Docket for examination by interested Standard Order contains minimum performance re- persons. quirements for life preservers for use on civil aircraft This amendment is proposed under the authority of of the United States engaged in operation over water. Sections 313(a) and 601 of the Federal Aviation Act The amendment is proposed to clarify the existing of 1958 (72 Stat. 752, 775; 49 U.S.C. 1354(a), 1421). Technical Standard Order and to inelude standards In consideration of the foregoing it is proposed to for survivor locator lights. Flotation is the primary amend Part 514 by revising Section 514.23 to read and most important requirement for survival after as follows : escape from a ditched aircraft.]
- Removed
[removed: ing the Technical fitandard Order. This Technical Standard Order contains minimum performance requiremf'nts for life preserverf-i for use on civil aircraft of the enited States engaged in opemtion over water.] - Added
[added: The possibility of § 514.23 Life preservers—TSO-C13d. survival is greatly increased if the survivor expedítiously boards one of the airplanes life rafts or a (a) Applicability. Minimum performance standrescue vessel. To insure and facilitate the location of ards are hereby established for life preservers (adult all survivors at night a means of illumination on the and child) including survivor locator lights which life preservers must be provided. A review of air- specifically are required to be approved for use on craft ditehings confirms that where lights on life civil aircraft of the United States.]
- Removed
[removed: The amendment is proposed to clarify the existing Technieal Standard Ol'rter and to include standard!'! for survivor locator light:;;. Flotation is the primal',v and most important requirement for survival after escape from a ditched aircraft. The pORsibility of survival is greatly increased if the ,<;urvivor expeditiously hoards one of the airplanes life rafts or a rpS('IIP vf'ssel. '1'0 inSlirp and facilitnte the location of nIl survivors at night a means of illumination on the life preservers must he provirled. A J'eview of air- (Taft ditchings confirms that \vhere lights on life preseners were provided, persons in the water who might otherwise not have been snvert \vere sightell and pickf'd up in life rafts or rescue vessels.] - Added
[added: New models of preservers were provided, persons in the water who life preservers manufactured on or after the effective might otherwise not have been saved were sighted date of this section shall meet the requirements speciand picked up in life rafts or rescue vessels. fied in Federal Aviation Standard "Life Preservers", Under this proposal the requirements would now dated July 26, 1963.1 Survivor locator lights which be incorporated into an FAA Standard instead of meet the requirements of this TSO may be mounted referring to an industry specification as was done in on previously approved life preservers. the previous TSO. The proposed TSO primarily in- (b) Markings. corporates those standards set forth in the previous (1) The life preservers shall be permanently TSO. The main substantive change is the new re- marked in accordance with the provisions of § 514.3 quirement for survivor locator lights.]
- Removed
[removed: Undf'l' this proposal the requirements would now be incorporatf'd into an FAA Standard instead of referring to an industry specification as was done in the previom:; TSO. The proposed TRO primarily in- ('orpol'ates those standards set forth in the previous 'fRO. The main substantive changf" is the new requirf"ment for survivor locator lights. Survivor locator lights which mef't the standards prescribed in this TSO may be mounted on previously approved life prf'sprvers.] - Added
[added: Survivor loca- (d) except for the following: tor líghts which meet the standards prescribed in this (i) The weight of the life preserver assembly TSO may be mounted on previously approved life may be omitted; preservers. (ii) The date of manufacture of fabric (month Interested persons are invited to participate in the and year) shall be shown; and making of the proposed rule by submitting such writ- (iii) The intended user, i.e., "adult", "child", or "adult and child" shall be shown. ten data, views or arguments as they may desire. Communications should identify the regulatory docket (2) The survivor locator light shall be permanumber and be submitted in duplicate to the Federal nently marked in accordance with provisions of Aviation Agency, Office of the General Counsel: § 514.3(d) except for the following: Attention Rules Docket, Room A-103, 1711 New York (i) The weight of the survivor locator light Avenue, N.W., Washington, D.C. 20553.]
- Removed
[removed: Interested persons are invited to participate in the making of the proposed rule by suhmitting such written data, views or arguments aR they may desire. ('ornmllnil'fttiom; Rhould identify the regulatory docket number and be submitted in duplicate to the Federal Aviation Agency, Office of the General Counsel: Attention Rules Docket, Room A-I03, 1711 New York Avenue, :.\'".W., Washington, D.C. 205!'i3. All communications rf'c(>ived on 01' hf>fOl'e Octoher 9, 196H, will be ('onsidered by the Arlministrator before taking action upon the pl'opoRefl rulf'. The proposals ('ontained in] - Added
[added: AI1 commun- may be omitted. ications received on or before October 9, 1963, will be 1 Copies may be obtained upon request addressed to Pubconsidered by the Administrator before taking action lishing and Graphics Branch, Inquiry Section, HQ-440, Fedupon the proposed rule. The proposals contained in eral Aviation Agency, Washington, D.C. 20553]
- Removed
[removed: this notice may be changed in the light of comments received. All comments submitted will be available, both before and after the closing date for comments, in the Rules Docket for examination by interested persons.] - Added
[added: (c) Data requirements. In accordance with the provisions of § 514.2. as applicable. manufacturers of life preservers and the survivor locator lights shall furnish to the Chief, Engineering and Manufacturing Branch, Flight Standards Division, Federal Aviation Agency in the region in which the manufacturer is located, the following technical data :]
- Removed
[removed: This amendment is proposed under the authority of Sertions 313 (a) and 601 of the Federal Aviation Act of 1958 (72 Stat. 702. 775; 49 U.S.C. 1304(a), 1421).] - Added
[added: Issued in Washington, D.C., on August 5, 1963.]
- Removed
[removed: In consideration of the foregoing it is proposed to amend Part 1)14 by revising Section 514.23 to read as follows:] - Added
[added: (1) Six copies of an instruction manual deseribing the products and containing information for the maintenance, overhaul and installation of the life preserver and the survivor locator light : (2) Six copies of the necessary data detailing the mounting of the survivor locator light on the life preserver.]
- Removed
[removed: § 1)14.23 Lite presert1e1'8-TSO-CnJd.] - Added
[added: Acting pirector Flight Standards Service]
- Removed
[removed: (a) Applica bilUy. Minimum performance standards are hereby established for life preservers (adult and child) including survivor locator lights which specifically are required to be approved for use on civil aircraft of the United States. New models of life preservers manufactured on or after the effective date of this section shall meet the requirements specified in Federal Aviation Standard "Life Preservers", dated July 26, 1963.1 Rurvivor locator lights which meet the requirements of this TSO may be mounted on previously approved life preservers.] - Added
[added: JuLr 26, 1963]
- Removed
[removed: (b) Marking8.] - Removed
[removed: (1) The life preRervers sha1l be permanently marked in accordance with the provisions of § 514.3] - Removed
[removed: (d) except for the following:] - Removed
[removed: (i) The weight of the life preserver assembly may be omitted;] - Removed
[removed: (ii) The date of manufacture of fabriC (month and year) shall be shown; and] - Removed
[removed: (iii) The intended user, I.e., "adult", "('hild", or "adult and child" shall be shown.] - Removed
[removed: (2) The survivor locator light shall be permanently marked in accordance with provisions of * 514.3(d) except for the following: (i) The weight of the survivor locator light may be omitted.] - Removed
[removed: 1 Copies may be obtained upon request addressed to Publishing and Graphics Branch, Inquiry Section, HQ-440, Federal Aviation Agency, Washington, D.C. 20553] - Removed
[removed: (c) Data requirements. In 8C'<.'Ordance with the pro'Visions of § 514.2. a8 applicable. manufacturers of life preser'Vers and the suni\'or lO<'ator li,2'hts ~hall furnish to the Chief, Engineering and :\Ianufllcturing Branch, Flig-ht Standards Di'Vision. Federal A'Viation Agency in the region in which the manufacturer is] - Removed
[removed: located, the following teehnic-al data:] - Removed
[removed: Issued in Washington. D.C,. on August 5, 1963.] - Removed
[removed: (1) Six ('opies of an instru('tion manual des('rih· ing the produ('tl; and ('ontaining information for the maintenan('e, o'Ve-rhaul and installation of the- lifl;'] - Removed
[removed: prl;'sen-er and rhl;' sUn"i'Vor locator light:] - Removed
[removed: (2) Six ('opi€'s of the ne-ces..<mry data de-tailin~ the mounting of th€' sUr'Vi'Vor locator Jig-ht on the life preser\'er.] - Removed
[removed: JULY 26, 1963] Federal Aviation Agency Standard
- Removed
[removed: For Life Preservers] - Added
[added: For]
- Removed
[removed: 1.0 Purpose. To establish minimum performance requirements for life preservers including survivor locator lights for use on civil aircraft of the United States engag-etl ifl operation over water.] - Added
[added: Life Preservers]
- Changed
[added: 1.0 Purpose. To establish minimum performance requirements for life preservers including survivor locator lights for use on civil aircraft of the United States engaged in operation over water. ]1.1
[removed: Scope.][added: Seope.] This standard covers life preservers (adult and child and a combination of both) and survivor locator lights intended for the use of occupants of civil[removed: air{'raft][added: aireraft] operating over water in the event of a ditching. Each life preserver shall be provided with a survivor locator light. Hereinafter, the term "life preserver" will include the survivor locator light as[removed: ,,'ell][added: well] as the life[removed: preservet'o][added: preserver.] Special requirements for child life preservers are[removed: eontained][added: contained] in paragraph 6.0 of this standard.[added: 2.0 Applicable Specifcations. The following specifications, as applicable, shall form a part of this standard and shall include the latest revisions at the time of manufacture or, in the event that any are canceled or superseded, the revision of the specification last in effect shall apply. 2.1 Military Specifications.] - Removed
[removed: 2.0 Applicable Specifications. The following specifications, as applicable, shall form a part of this standard and shall indude the latest revisions at the time of manufacture or, in the event that any are canceled or superseded, the revision of the specification last in effect shall apply.] - Added
[added: MIL–C–5540 Adhesive Neoprene MIL-T-7807 Thread Nylon MIL-V-6077 Vest, Life Preserver, Pneumatic MIL-C-19002 Cloth and Cloth Tape, Coated, Pneumatic Life Preserver MIL-C-00601 Cylinder, Carbon Dioxide Filled (For Pneumatic Life Vests and Similar Uses) MII-W-21733 Webbing, Textile Nylon Pneumatic Life Preserver MIL-W-530 Webbing, Cotton, Natural or in Colors 2.2 Federal Specifications. FED-STD-601 Federal Test Method, Rubber sampling and testing CCC-T-191 Textile Test Methods QQ-M-151 Metals, general specification for inspection of FED-STD-595 Colors for ready mixed paints 2.3 American Society for Testing Materials. ASTM-D573-53 Method of test for accelerated aging of vulcanized rubber, by the oven method ASTM-D751-52T Methods of testing rubber coated fabrics 3.0 Materials and Workmanship. 3.1 Workmanship. Life preservers shall be constructed in a thorough workmanship manner. The finished items shall be free from any defects that might affect function or appearance.]
- Removed
[removed: 2.1 Military Specifications. MIL-C-5540 Adhesive ~eoprene :\IIL-T-7807 Thread ~ylon :\HL-V---6077 Vest, Life Preserver, Pneumatic MIL-C-19002 Cloth and Cloth Tape, Coated,] - Added
[added: 3.2 Age of Nonmetallic Materials. All nonmetallic fabricated raw materials and components used in the manufacture of the life preservers shall have been manufactured not more than 12 months prior to the date of delivery of the finished product. 3.3 Coated Fabrics. All coated fabrics used in the manufacture of life preservers shall, except as otherwise provided, possess 90 percent of the physical properties called for under their applicable specifcations after these coated fabrics have been subjected to an accelerated aging test in accordance with ASTM-D573-53. 3.3.1 Flotation Chambers. Coated fabrics used for this application shall conform to the following minimum test specifications per ASTM-C751-52T: a. Tensile Strength—(Grab Test) Warp 210 lbs./inch minimum Fill 180 1bs./inch minimum b. Tear Strength—(Tongue or Strip Method— Raw Cloth) 10 x 10 lbs./inch minimum c. Permeability—Permeability to helium of not more than 5 liters per square meter per 24 hrs. at 77° F. (maximum) d. Coat Adhension—10.0 lbs./inch width 3.3.2 Seam Tape.]
- Removed
[removed: Pneumatic Life Preserver )IIL-C-OOGOl Cylinder, Carbon Dioxide Filled] - Added
[added: Tape used for the purpose of reinforcement of seams shall be suitable for the intended purpose. 3.4 Other Fabrics and Materials. 3.4.1 Webbing. Webbing used for the purpose of attaching the life preserver to the wearer shall be suitable for the intended purpose. 3.4.2 Thread. Thread used in the manufacture of life preservers shall be suitable for the intended purpose. 3.5 Seam Strength and Adhesives. Adhesives used in the manufacture of life preservers shall conform to appropriate specifications and shall develop minimum strength values specified therein. 3.6 Fungus Protection. All fabrics, threads and webbing used in the finished product which contain nutrient which will support fungus growth shall be suitably treated to prevent such growth. 3.7 Corrosion Protection. Metallic parts exposed to the atmosphere shall be corrosion resistant or protected against corrosion. 3.8 Flame Resistance. All material used in the life preserver shall be at least flame resistant.]
- Removed
[removed: (~~or Pneumatic Life Vests and Similar Uses) :\'IIL-W-21733 Webbing, Textile Nylon Pneumatic] - Added
[added: 3.9 Color. The life preserver color texcept the locator light )shall be Spanish Yellow. No. 70068. conforming to MIL—C-19002 or a color of equivalent high intensity. Note.—Crewmember life preservers. for the purpose of conspicuousness during an emergency. may be of a high intensity Red Color. 3.10 Temperature Limits. Materials used in the manufacture of life preservers and survivor locator lights shall not be affected by exposure to temperatures from − 40: F. to + 160: F.]
- Removed
[removed: Life Preserver l\IIL-W-530 Webbing, Cotton, Natural or in] - Removed
[removed: Colors 2.2 Federal Specifications. FED-STD-601 Federal Test )Iethod, Rubber sam-] - Removed
[removed: pling and testing CCC-T-l91 Textile Test l\Iethods QQ-)1-151 Metals, general specification for in-] - Removed
[removed: spection of] - Removed
[removed: FJ<~D-RTn-fi9fj Colors for rearly mixed paints 2.3 American Society for Testing Materials. AST:\I-Dfi73-53 Method of test for accelerated] - Removed
[removed: aging of vulf'anized rubber, hy the oven method AST:\I-D751-52T l\fethods of testing rubber ('ollted fahrif's 3.0 Materials and Workmanship. 3.1 Workmanship. Life preservers shall be constructed in a thorough workmanship manner. The finished items shall be fl'ee from any defects that might affect fun('tion or appearance.] - Removed
[removed: 3.2 Age of Nonmetallic Materials. All nonmetallic fabricated raw materials and components used in the manufacture of the Ufe preservers shall have been manufactured not more than 12 months prior to the date of delivery of the finished product.] - Removed
[removed: 3.3 Coated Fabrics. All coated fabriCS used in the manufacture of life preservers shall, except as otherwise provided, possess 90 percent of the physical properties called for under their applicable specifications after thpse coated fabrics have been subjected to an accelerated aging test in accordance with ASTM-D573-53.] - Removed
[removed: 3.3.1 Flotation Chambers. Coated fabrics used for this application shall conform to the following minimum test specifications per ASTM-C751-52T:] - Removed
[removed: a. Tensile Strength-(Grab Test)] - Removed
[removed: Warp 210 lbs./inch minimum Fill 180 lbs./inch minimum b. Tear Strength-(Tongue or Strip Method-] - Removed
[removed: Raw Cloth) 10 x 10 lbs./inch minimum c. Permeability-Permeability to hellum of not] - Removed
[removed: more than 5 liters per square meter per 24 hrs. at 77" F. (maximum) d. Coat Adhension-10.0 Ibs.jinch width 3.3.2 Seam Tape. Tape used for the purpose of reinforcement of seams shall be suitable for the] - Removed
[removed: intended purpose.] - Removed
[removed: 3.4 Other Fabrics and Materials. 3.4.1 Webbing. Webbing used for the purpose of attaching the life preserver to the wearer shall be suitable for the intended purpose.] - Removed
[removed: 3.4.2 Thread. Thread used in the manufacture of life preservers shall be suitable for the intended purpose.] - Removed
[removed: 3.5 Seam Strength and Adhesives. Adhesives used in the manufacture of life preservers shall conform to appropriate specifications and shall develop minimum strength values specified therein.] - Removed
[removed: 3.6 Fungus Protection. All fabrics, threads and webbing used in the finished product which contain nutrient which will support fungus growth shall be suitably treated to prevent such growth.] - Removed
[removed: 3.7 Corrosion Protection. Metallic parts exposed to the atmosphere shall be corrosion resistant or protected against corrosion.] - Removed
[removed: 3.8 Flame Resistance. All material used in the life preserver shall be at least flame resistant.] - Removed
[removed: 3.9 Color. The- life pr£'S{>ner ('Olor f eXC'ept the locator Ii/!'ht ~~hall be Spanish Yellow. :'\0. 70068. conforming to :\fIL-('-]fH)(r2 or a ('(Ilor of t"qui.al{'nt high intensity.] - Removed
[removed: XOTE.--CrewmeroJ:te.r life preservers.. for the purpose of conspicuousness during an emergency. may J:te. of a] - Removed
[removed: high intensity Red Color.] - Removed
[removed: 3.10 Temperature Limits. :\Iaterial.s used in the manufacture of Hfe }}reserwJ-i:. and 8.1ni"or locator] - Removed
[removed: lights shall not be affffted by eXJXlsure to temperatures from -..J,j)' F. to -lll1): F.] 4.0 Detail Requirements.
- Removed
[removed: 4.1 Re£'ersibility. The life prf"Ser\"er shall either be re.ersible or so dpsigned as to preclude the probahility of improper donning. If of the reH"I"$ible type, the sur.j\·or lncatnt lidn in:,taHation shall he suitahle for its intewlM purpoi't" whpn rlnnnPd in pit her mannpr.] - Added
[added: 4.1 Rerersibility. The life preserver shall either be reversible or so designed as to preclude the probability of improper donning. If of the reversible type, the survivor locator light installation shal be suitable for its intended purpose when donned in either manner. 4.2 Compartmentation. The life preserver shall have a minimum of two gas-tight compartments.]
- Removed
[removed: 4.2 Compartmentation. The lifp rH-p~ner shall ha\"e a minimlllll of two gTI:<:-ti!!'ht rompartments.] - Added
[added: 43 Inflation. Each compartment of the life pre server shall have separate individual means for both mechanical and oral inflation.]
- Removed
[removed: 4.3 Inflation. Each ("olllpartmenr Ilf thp life prespr.e-r shall hll\-e i't"parate innh-i(lual means for both fi\(,>("hani<'al and oral infia{i.(\n.] - Added
[added: 4.3.1 Oral Inflation. Means for orally inflating the life preserver shall be available for immediate use and readily recognizable by persons not having previous instructions in its use. The oral inflation device shall be located so as not to interfere with the face or body of the wearer. To inflate the life preserver compartment orally. it shall be necessary only to blow into the mouthpiece of the oral inflation means. 4.32 Oral Infation Valre. The orat inftation valves shali have an opening pressure of 0.6 p.s.i.g. maximum when no back pressure is present and shall not leak under back pressures between zero p.s.i.g. to 1ù p.s.i.g. 4.3.3 Mechanical Inflation. Mechanical inflation of the preserver shall be accomplished by CO, unless it can be demonstrated that some other means of inflation is equally suitable.]
- Removed
[removed: 4.3.1 Oral Inflation. "Ipan~ for orally inflating the life- prpSPrwr ~hall be a .. ailahll?' fflr immffiiatl?' U!le and rpartily rP<'Og"TIi7 .. Hhle hy Pf'J"i4)n~ not ha.ing- prf"-- .iolls in~tnl('tinn~ in it~ 1l~. The oral inflation oevice shall bp 10C'atPd ~o a:<: nor to interfe-r€' -with the faceor booy of thp w(>arf"r. To infiat(> thl?' life- prf>i't"ner ('ompartIDf'nt orally. it :-ohall be n~~rr only to blo-w] - Added
[added: 4.3.3.1 CO. System. One cylinder shall be provided to inflate fully each flotation compartment of the life preserver. Each inflation device shall consist of an inflator assembly. The inflator shall permit insertion of a cylinder. meeting specification MIL-C-00601 Type 1. into one end and shall contain the discharging device in the opposite end. The design of the inflator shalt be such that the installed cylinder shall he punctured with a travel of the lever arm of not more than 9t F. The inflator shall have provisions for safetying the lever. The lever of each inflator shall he provided with a pull cord assembly extending between 11g and 3 inches below the edge of the life preserver. The end of the pull cord assembly shall be attached to a red pull knob or tab which shall be used to activate the inflator. 4.3.3.2 Infator. The inflator shall withstand a hydrostatie pressure of 1.500 p.s.i. without deformation or leakage. The inflator shall not leak when subjected to 2 and 40 p.s.i. air pressure. respectively.]
- Removed
[removed: into thE' mouthpiPf'e of thE' oral inflation me-ans.] - Added
[added: with the lever at any position in its normal cycle of operation. The inflator shall have an opening pressure of 25 to 35 p.s.i. and shall allow a minimum flow of 4 liters of air per minute at 40 p.s.i. inlet pressure. The inflator shall not leak when subjected to a negative pressure of 12 inches of water applied so as to reduce the seating spring pressure and with atmospheric pressure on the opposite side. 4.4 Buoyancy. The life preserver (both compartments after inflation by the mechanical inflation means) shall provide a minimum of 23 pounds of buoyance in fresh water at 85° F.]
- Removed
[removed: 4.3.2 Oral Inflation "·alre. ThE" oral inflation] - Added
[added: 5.0 Adaptability for Wearer. 5.1 Flotation Attitude. The life preserver shall support the wearer in an upright position face up not less than 15 degrees nor more than 30 degrees from the vertical. The head shall be so supported that the wearer's face shall be out of the water when he is unconscious or completely relaxed.]
- Removed
[removed: \'aj\-~ :-ohall ha.f' an "ppnin:: r~.;:.t11"(> of n.t') p.s.i.g. maximum whf'n no h:v'k P~';:'Un? b p~nt amI shall not lellk unnpr ha("k prf':<:$t1n;>;:. hf>rween Zl?'rfl p.:<:.i./!,. to] - Added
[added: 5.2 Donning Life Preserver. The life preserver shall be easily donned by a person with a minimum amount of instruction and shall be reasonably comfortable. It shall be capable of being donned by the wearer without assistance while in a sitting position. The life preserver shall be so attached to the wearer that it shall not slip off when jumping into the water from a height of 5 feet: however, straps which pass between the wearer's legs are not permissible. The life preserver shall not chafe the wearer's legs, neck or restriet breathing or blood circulation.]
- Removed
[removed: 1(1 p.s.i..!!.] - Added
[added: 5.3 Fastenings and Attachments. The means of attachment of the life preserver by straps or fasteners shall be conveniently located and easily operated by the wearer under emergency lighting conditions. There shall be a means of adjustment of the life preserver attaching means when inflated, to fit the wearer. Attachment fastening devices shall develop at least 80 percent of the tensile strength of the straps to which they are fastened without loosening. slipping or causing tearing of straps.]
- Removed
[removed: 4.3.3 .1Iechankal Inflation. ){f'('haniral inflation of the prf":"f'rw'r :-ohall hf' al'("'nmp\j~hf'(l fly ('()~ unless it can be nemon:-otr:ltPf1 rhnt ~)mp othf'r means of infla-] - Added
[added: 6.0 Child Life Preserver. All provisions of this standard apply to child life preservers with the exception of the changes indicated in the subparagraph of this paragraph. For purposes of this standard, a child is considered to be in the age bracket of 2 to 6 years.]
- Removed
[removed: tion is PQually :<:uitahll?'.] - Added
[added: 6.1 Flotation Attitude. The child life preserver shall support the wearer in a face up attitude so that the wearer's face will he supported above the water line even when he is unconscious or completely relaxed.]
- Removed
[removed: 4.3.3_1 CO~ System. Onl?' rylinnpr shall bP pro.iderl to inflatf> fully (>n('h ftotntion ('Omparttnf>nt llf the life prf>S€'r\·l?'r. Earh inftation (jP\-if"P shall mnsist of an inflator a:-<"<:'(>lIlhly. Thf> inflator ~hall Pf'rmit insertion of a C'~·li.n(ter. me-eri.ng ~ifirnti(\n :.\[(L--C-00601 Type 1. into onl?' end and ~hall ('ontain the di~charg] - Added
[added: 6.2 Compartmentation. The child life preserver shall have a minimum of one gastight compartment.]
- Removed
[removed: ing de.ire in thp oppo:<:itp I?'nd. The nl?'l"ign of the inflator shall hf> ~u('h that thl?' in~tallM ('rlinner shall] - Added
[added: 6.3 Buoyancy. The child life preserver shall provide a minimum of 9 pounds of buoyancy in fresh water at 70° F.]
- Removed
[removed: hI?' punctur~-I wirh a trll'el nf rhf' I('w'r arm of not more than nfl: F. The inflator ~hall ha.e pro'isions fnr saferyin;!, thl?' II?"er. Thp le\'l?'r of each inflator] - Added
[added: 6.4 Donning Life Preserrer. For the child life preserver, it is acceptable to incorporate straps which pass between the child's legs.]
- Removed
[removed: ~hal1 he proyinPfI with a pull cord as...;;pmbly extending betwf'en 11~ an(I ~ jW'hE':" Tlf>\OW thl?' Pil!!f' of the life] - Removed
[removed: pre~l?'t\"er. Thf> I?'n(1 flf thf' pull rorn as-.<:.f>mblr ~hall be attar-hed to a red pull knoh or tah whi('h ~hall he lI:<:Pfl tll arti.ate thf' inflator.] - Removed
[removed: 4.3.3.2 Inflator. The inflator shaH withstanrl a hydrostatil' pr{>S..~l1r{> of l})Ofl p.s.L tritho\1t neformation or leaka(!'l?'. The inflator ~hall n.)t leak 'Whf'n subjected to 2 and 40 p.s.L air pres:,.--ure. re::,.--PP<'ti\"ely.] - Removed
[removed: with the lever at any position in its normal cycle of operation. The inflator shaH ha .. e an opening pressure of 25 to 3n p.s.i. and shall allow a minimum flow of 4: liters of air per minute at 40 p.s.i. inlet pressure. The inflator shall not leak when subjected to a negati .. e pressure of 12 inches of wate-r applied so as to reduce the seating spring pressure and with atmospheric pr(>ssure on the oppo~ite side.] - Removed
[removed: 4.4 Buoyancy. The life pres-ervpr (both compartments after inflation by the mechanical inflation means) shaH provide a minimum of 23 pounds of buoyanee in fresh water at 85 0 F.] - Removed
[removed: 5.0 Adaptability for Wearer.] - Removed
[removed: 5.1 Flotation Attitude. The life pr~er .. er shall support the wearer in an uprig-ht position face up not less than 15 deg-rees nor more than 30 degrees from the .. ertica1. The head shall be so supported that the trearer's face shall be out of the 'Water when he is un<,onscious or <'ompletely relaxed.] - Removed
[removed: 5.2 Donning Life Preserver. The life preserver] - Removed
[removed: ~hal1 be ea~ilr donned. by a person 'With a minimum amount of instruf'tion and shall be reasonably comfOl"table. It shall be capable of being donned by the wearer without assistance while in a sitting- pOSition. The liff> pre~l?'n-f>r shaH be so attached. to the wearer that it shall not slip off 'When jumping into the water from a hl?'ight of fi feet: ho'Wever. straps which pass between the wearE'r's legs are not p{'rmissible. The life presl?'rver shall not <'hafe the 'Wearer's legs, nP<'k fir re-stri('l brNlthing or hlood eir<'ulation.] - Removed
[removed: 5.3 Fastenings and Attachments. The meanS of Htta('hml:"nt of the lifp prese-rve-r by straps or fasteners shall hf' ("on\"enil?'ntly lo("atl?'rl anrl easily operated by thl?' tr(>nrel" undl?'r pmprgency lighting conditions. Therl?' ~hall hI?' a ml?'ans of adjustment of the life presen'er nttachin/!' mpans when inflated, to fit the wearer. Attaehml?'nt fastening devices shall develop at 1(>8st 80 pe-l'(,E'nt of the tensile strength of the straps t() whir-h th(>y are fastened without 10osl?'ning. Slipping or causing tearing of straps.] - Removed
[removed: 6.0 Child Life Preserver. All provisions of this stanrtnrd apply to child life presenE-rs with the ex· (,f'ption flf th{' ("hanges indicatE-d in the subparagraph of this parag-raph. For purposes of this standard, a rhilrl is ('nnsirll?'rf'rt to he in thE' ag-f' bra('kE't flf 2 to 6] - Removed
[removed: yf>ar~.] - Removed
[removed: 6.t Flotation Attitude. The chilo liff' preserver shnll support thf' wl?'arl?'r in a f!l<'P up attitude so that the trf'nrer's fa ("I?' will he snpport(>o ahove the water linf' I?'vl?'n 'Whl?'n hI?' is 11ll('onf':cio1l8 or rompll?'tel~' relaxed.] - Removed
[removed: 6.2 Compartmentation. The child life preserver shall ha\'f' n minim\ltl1 of one ~asti,g-ht compartment.] - Removed
[removed: 6.3 Buoyancy. Thl?' r-hild Iifl?' prE'f':er,€'r shall providE' a minimum of 9 pounds of buoyancy in fresh watpr at 70 0 F.] - Removed
[removed: 6,4 Donning Life Preserrer. For the child life PI"{,f':f'r\'f'I" it if; a('('{>ptnbll?' to in('orporate straps whirh] - Removed
[removed: pas~ hetwe-en the child's legs.] 7.0 Survivor Locator Light.
- Removed
[removed: 7.1 Survivor Locator Light. Each life preserver shall be provided with a white survivor locator light complying with the provisions of this standard.] - Added
[added: 7.1 Survivor Locator Light. Each life preserver shall be provided with a white survivor locator light complying with the provisions of thís standard. 7.1.1 Survivor Locator Light Intensity. The survivor locator light shall provide a minimum effective intensity of 3 candles in the direction specified in paragraph 7.1.2 for a period of 8 hours. Effective intensity is that intensity which will give the same visual range as would a fixed light of the same color under identical conditions of operation. If a flashing light is used, effective intensity shall be computed from the following formula :]
- Removed
[removed: 7.1.1 Survivor Locator Light Intensity. The survivor locator light shall provide a minimum effective intensity of 3 candles,in the direction specified in paragraph 7.1.2 for a period of 8 hours. Effective] - Added
[added: I(t) dt]
- Removed
[removed: intensity is that intensity which will give the same visual range as would a fixed light of the same color under identical conditions of operation. If a flashing light is used, effective intensity shall be computed from the following formula:] - Added
[added: Ie= 0.2+(T2−T1)]
- Removed
[removed: where:] - Added
[added: where: Ie=effective Intensity (candles) I(t) =instantaneous intensity as a function of time T2-T1= fiash interval in seconds]
- Removed
[removed: Ott)dt j~, Ie= --=::-'~--] - Added
[added: 7.1.2 Light Distribution. The light shall be mounted on the life preserver so as to provide illumination in all directions in the horizontal plane. 7.1.3 Attachment. The light shall incorporate a device to enable it to be easily attached to and detached from the life preserver. 7.1.4 Waterproofing. The light shall be waterproofed to the extent that prolonged immersion in fresh or salt water will not affect its operation. 7.1.5 Switch. Means for turning the light on and off shall be provided. Such means shall be readily available to the user. 8.0 Required Tests.]
- Removed
[removed: 0.2+ ('1'2-T,)] - Added
[added: 8.1 Initial Qualification Tests. The tests indicated in the following subparagraphs shall be conducted for initial qualification. These tests shall be conducted on a minimum of three samples. Each test article shall be representative of production units and shall be individually identified.]
- Removed
[removed: le= effective Intensity (candles) I (t) ::::: instantaneous intensity as a function] - Added
[added: 8.1.1 Buoyancy. When mechanically inflated and placed in fresh water at-a·temperature of 70° F. the life preserver shall support a 20 pound steel weight without becoming submerged. (In the case of a child life preserver, it shall support a 9 pound weight. 8.1.2 Salt Spray. All metal parts shall operate satisfactorily and shall not corrode when subjected to a salt spray in accordance with Federal Specification QQ–M–151 for a period of 100 hours. 8.1.3 Rubber Goods. A sample of rubber goods shall be tested in accordance with specification FED- STD-601. 8.1.4 Textiles. A sample of textile goods shall be tested in accordance with specification CCC-T-191. 8.1.5 Survivor Locator Light Intensity. It shall be demonstrated that the survivor locator líght provides a minimum effective intensity of 3 candles for a period of 8 hours. 8.1.6 Flame Resistance. All nonmetallic materials shall be tested for flame resistance in accordance with Federal Specification CCC-T-191, Method 5906. 8.1.7 Pressure Test.]
- Removed
[removed: of time T 2-T1 -= flash interval in seconds] - Added
[added: Each compartment of each test sample life preserver shall withstand separately without failure an air pressure of 10 p.s.i.g. for 5 minutes. 8.1.8 Survivor Locator Light Watertightness. Each test sample light shall be submerged for a period of 8 hours in fresh water at 70° F. to such a depth that the highest point of the light is under a three foot head. After removal from the water, the light shall be examined to determine that no leakage has taken place. 8.2 Individual Performance. 8.2.1 Life Preserver. Each compartment of each life preserver manufactured shall be inflated with oil free air at 70° F. to a pressure of 2 p.s.i.g. After a 12 hour period, the pressure loss shall not be in excess of 1⁄2 p.s.i.g. 8.2.2 Survivor Locator Light. Each survivor locator light shall be operated to demonstrate that the assembly is in an operating condition by lighting the light with the means provided.]
- Removed
[removed: 7.1.2 Light Distribution. The light shall be mounted on the life preserver so as to provide illumination in all directions in the horizontal plane.] - Added
[added: 3316—64]
- Removed
[removed: 7.1.3 Attachment. The light shall Incorporate a device to enable it to be easily attached to and detached from the life preserver.] - Removed
[removed: 7.1.4 Waterproofing. The light shall be waterproofed to the extent that prolonged immerSion in fresh or salt water will not affect its operation.] - Removed
[removed: 7.1.5 Switch. Means for turning the light on and off shall be provided. Such means shall be readily available to the user.] - Removed
[removed: 8.0 Required Tests.] - Removed
[removed: 8.1 Initial Qualification Tests. The tests indicated in the following subparagraphs shall be conducted for initial qualification. These tests shall be conducted on a minimum of three samples. Each test article shall be representative of production units and shall be indivldually identified.] - Removed
[removed: 8.1.1 Buoyancy. When mechanically inflated and placed in fresh water at-a ·temperature of 70° F. the life preserver shall support a 20 pound steel weight without becoming .submerged. (In the case of a child life preserver, it shall support a 9 pound weight.)] - Removed
[removed: 8.1.2 Salt Spray. All metal parts shall operate satisfactorily and shall not corrode when subjected to a salt spray in accordance with Federal Specification QQ-M-151 for a period of 100 hours.] - Removed
[removed: 8.1.3 Rubber Goods. A sample of rubber goods shall be tested in accordance with specification FED-] - Removed
[removed: STD-60l.] - Removed
[removed: 8.1.4 Textiles. A sample of textile goods shall be tested in accordance with specification CCC-T-191.] - Removed
[removed: 8.1.5 Survivor Locator Light Intensity. It shall be demonstrated that the survivor locator light provides a minimum effective intensity of 3 candles for a period of 8 hours.] - Removed
[removed: 8.1.6 Flame Resistance. All nonmetallic materials shall be tested for fhime resistance in accordance with Federal Specification CCC-T-191, Method 5906.] - Removed
[removed: 8.1.7 Pressure Test. Each compartment of each test sample life preserver shall withstand separately without failure an air pressure of 10 p.s.i.g. for 5 minutes.] - Removed
[removed: 8.1.8 Survivor Locator Light Watertightness. Each test sample light shall be submerged for a period of 8 hours in fresh water at 700 I( to such a depth that the highest point of the light is under a three foot head. After removal from the water, the light shall be examined to determine that no leakage has taken place.] - Removed
[removed: 8.2 Individual Performance. 8.2.1 Life Preserver. Each compartment of each life preserver manufactured shall be inflated with oil free air at 70° F. to a pressure of 2 p.s.i.g. After 11 12 hour period, the pressure loss shall not be in excess of 112 p.s.i.g.] - Removed
[removed: 8.2.2 Survivor Locator Light. Each survivor locator light shall be operated to demonstrate that the assembly is in an operating condition by lighting the] - Removed
[removed: light with the means provided.]
Whole text before this change
FEDERAL AVIATION AGENCY
FLIGHT STANDARDS SERVICE
[14 CFR 514] [Regulatory Docket No. lRD2; Kotice Ko. 63~31]
TECHNICAL STANDARD ORDERS FOR AIRCRAFT MATERIALS,
PARTS AND APPLIANCES
NOTICE OF PROPOSED RULE MAKING
Life Preservers-TSO-C13d
The Federal Aviation Agency has under consideration II pJ"Opmml to revif'e Section fiH.2R of Part 514 of the Hegnlations of the Administrator by amend-
ing the Technical fitandard Order. This Technical Standard Order contains minimum performance requiremf'nts for life preserverf-i for use on civil aircraft of the enited States engaged in opemtion over water.
The amendment is proposed to clarify the existing Technieal Standard Ol'rter and to include standard!'! for survivor locator light:;;. Flotation is the primal',v and most important requirement for survival after escape from a ditched aircraft. The pORsibility of survival is greatly increased if the ,<;urvivor expeditiously hoards one of the airplanes life rafts or a rpS('IIP vf'ssel. '1'0 inSlirp and facilitnte the location of nIl survivors at night a means of illumination on the life preservers must he provirled. A J'eview of air- (Taft ditchings confirms that \vhere lights on life preseners were provided, persons in the water who might otherwise not have been snvert \vere sightell and pickf'd up in life rafts or rescue vessels.
Undf'l' this proposal the requirements would now be incorporatf'd into an FAA Standard instead of referring to an industry specification as was done in the previom:; TSO. The proposed TRO primarily in- ('orpol'ates those standards set forth in the previous 'fRO. The main substantive changf" is the new requirf"ment for survivor locator lights. Survivor locator lights which mef't the standards prescribed in this TSO may be mounted on previously approved life prf'sprvers.
Interested persons are invited to participate in the making of the proposed rule by suhmitting such written data, views or arguments aR they may desire. ('ornmllnil'fttiom; Rhould identify the regulatory docket number and be submitted in duplicate to the Federal Aviation Agency, Office of the General Counsel: Attention Rules Docket, Room A-I03, 1711 New York Avenue, :.\'".W., Washington, D.C. 205!'i3. All communications rf'c(>ived on 01' hf>fOl'e Octoher 9, 196H, will be ('onsidered by the Arlministrator before taking action upon the pl'opoRefl rulf'. The proposals ('ontained in
this notice may be changed in the light of comments received. All comments submitted will be available, both before and after the closing date for comments, in the Rules Docket for examination by interested persons.
This amendment is proposed under the authority of Sertions 313 (a) and 601 of the Federal Aviation Act of 1958 (72 Stat. 702. 775; 49 U.S.C. 1304(a), 1421).
In consideration of the foregoing it is proposed to amend Part 1)14 by revising Section 514.23 to read as follows:
§ 1)14.23 Lite presert1e1'8-TSO-CnJd.
(a) Applica bilUy. Minimum performance standards are hereby established for life preservers (adult and child) including survivor locator lights which specifically are required to be approved for use on civil aircraft of the United States. New models of life preservers manufactured on or after the effective date of this section shall meet the requirements specified in Federal Aviation Standard "Life Preservers", dated July 26, 1963.1 Rurvivor locator lights which meet the requirements of this TSO may be mounted on previously approved life preservers.
(b) Marking8.
(1) The life preRervers sha1l be permanently marked in accordance with the provisions of § 514.3
(d) except for the following:
(i) The weight of the life preserver assembly may be omitted;
(ii) The date of manufacture of fabriC (month and year) shall be shown; and
(iii) The intended user, I.e., "adult", "('hild", or "adult and child" shall be shown.
(2) The survivor locator light shall be permanently marked in accordance with provisions of * 514.3(d) except for the following: (i) The weight of the survivor locator light may be omitted.
1 Copies may be obtained upon request addressed to Publishing and Graphics Branch, Inquiry Section, HQ-440, Federal Aviation Agency, Washington, D.C. 20553
(c) Data requirements. In 8C'<.'Ordance with the pro'Visions of § 514.2. a8 applicable. manufacturers of life preser'Vers and the suni\'or lO<'ator li,2'hts ~hall furnish to the Chief, Engineering and :\Ianufllcturing Branch, Flig-ht Standards Di'Vision. Federal A'Viation Agency in the region in which the manufacturer is
located, the following teehnic-al data:
Issued in Washington. D.C,. on August 5, 1963.
(1) Six ('opies of an instru('tion manual des('rih· ing the produ('tl; and ('ontaining information for the maintenan('e, o'Ve-rhaul and installation of the- lifl;'
prl;'sen-er and rhl;' sUn"i'Vor locator light:
(2) Six ('opi€'s of the ne-ces..<mry data de-tailin~ the mounting of th€' sUr'Vi'Vor locator Jig-ht on the life preser\'er.
JULY 26, 1963
Federal Aviation Agency Standard
For Life Preservers
1.0 Purpose. To establish minimum performance requirements for life preservers including survivor locator lights for use on civil aircraft of the United States engag-etl ifl operation over water.
1.1 Scope. This standard covers life preservers (adult and child and a combination of both) and survivor locator lights intended for the use of occupants of civil air{'raft operating over water in the event of a ditching. Each life preserver shall be provided with a survivor locator light. Hereinafter, the term "life preserver" will include the survivor locator light as ,,'ell as the life preservet'o Special requirements for child life preservers are eontained in paragraph 6.0 of this standard.
2.0 Applicable Specifications. The following specifications, as applicable, shall form a part of this standard and shall indude the latest revisions at the time of manufacture or, in the event that any are canceled or superseded, the revision of the specification last in effect shall apply.
2.1 Military Specifications. MIL-C-5540 Adhesive ~eoprene :\IIL-T-7807 Thread ~ylon :\HL-V---6077 Vest, Life Preserver, Pneumatic MIL-C-19002 Cloth and Cloth Tape, Coated,
Pneumatic Life Preserver )IIL-C-OOGOl Cylinder, Carbon Dioxide Filled
(~~or Pneumatic Life Vests and Similar Uses) :\'IIL-W-21733 Webbing, Textile Nylon Pneumatic
Life Preserver l\IIL-W-530 Webbing, Cotton, Natural or in
Colors 2.2 Federal Specifications. FED-STD-601 Federal Test )Iethod, Rubber sam-
pling and testing CCC-T-l91 Textile Test l\Iethods QQ-)1-151 Metals, general specification for in-
spection of
FJ<~D-RTn-fi9fj Colors for rearly mixed paints 2.3 American Society for Testing Materials. AST:\I-Dfi73-53 Method of test for accelerated
aging of vulf'anized rubber, hy the oven method AST:\I-D751-52T l\fethods of testing rubber ('ollted fahrif's 3.0 Materials and Workmanship. 3.1 Workmanship. Life preservers shall be constructed in a thorough workmanship manner. The finished items shall be fl'ee from any defects that might affect fun('tion or appearance.
3.2 Age of Nonmetallic Materials. All nonmetallic fabricated raw materials and components used in the manufacture of the Ufe preservers shall have been manufactured not more than 12 months prior to the date of delivery of the finished product.
3.3 Coated Fabrics. All coated fabriCS used in the manufacture of life preservers shall, except as otherwise provided, possess 90 percent of the physical properties called for under their applicable specifications after thpse coated fabrics have been subjected to an accelerated aging test in accordance with ASTM-D573-53.
3.3.1 Flotation Chambers. Coated fabrics used for this application shall conform to the following minimum test specifications per ASTM-C751-52T:
a. Tensile Strength-(Grab Test)
Warp 210 lbs./inch minimum Fill 180 lbs./inch minimum b. Tear Strength-(Tongue or Strip Method-
Raw Cloth) 10 x 10 lbs./inch minimum c. Permeability-Permeability to hellum of not
more than 5 liters per square meter per 24 hrs. at 77" F. (maximum) d. Coat Adhension-10.0 Ibs.jinch width 3.3.2 Seam Tape. Tape used for the purpose of reinforcement of seams shall be suitable for the
intended purpose.
3.4 Other Fabrics and Materials. 3.4.1 Webbing. Webbing used for the purpose of attaching the life preserver to the wearer shall be suitable for the intended purpose.
3.4.2 Thread. Thread used in the manufacture of life preservers shall be suitable for the intended purpose.
3.5 Seam Strength and Adhesives. Adhesives used in the manufacture of life preservers shall conform to appropriate specifications and shall develop minimum strength values specified therein.
3.6 Fungus Protection. All fabrics, threads and webbing used in the finished product which contain nutrient which will support fungus growth shall be suitably treated to prevent such growth.
3.7 Corrosion Protection. Metallic parts exposed to the atmosphere shall be corrosion resistant or protected against corrosion.
3.8 Flame Resistance. All material used in the life preserver shall be at least flame resistant.
3.9 Color. The- life pr£'S{>ner ('Olor f eXC'ept the locator Ii/!'ht ~~hall be Spanish Yellow. :'\0. 70068. conforming to :\fIL-('-]fH)(r2 or a ('(Ilor of t"qui.al{'nt high intensity.
XOTE.--CrewmeroJ:te.r life preservers.. for the purpose of conspicuousness during an emergency. may J:te. of a
high intensity Red Color.
3.10 Temperature Limits. :\Iaterial.s used in the manufacture of Hfe }}reserwJ-i:. and 8.1ni"or locator
lights shall not be affffted by eXJXlsure to temperatures from -..J,j)' F. to -lll1): F.
4.0 Detail Requirements.
4.1 Re£'ersibility. The life prf"Ser\"er shall either be re.ersible or so dpsigned as to preclude the probahility of improper donning. If of the reH"I"$ible type, the sur.j\·or lncatnt lidn in:,taHation shall he suitahle for its intewlM purpoi't" whpn rlnnnPd in pit her mannpr.
4.2 Compartmentation. The lifp rH-p~ner shall ha\"e a minimlllll of two gTI:<:-ti!!'ht rompartments.
4.3 Inflation. Each ("olllpartmenr Ilf thp life prespr.e-r shall hll\-e i't"parate innh-i(lual means for both fi\(,>("hani<'al and oral infia{i.(\n.
4.3.1 Oral Inflation. "Ipan~ for orally inflating the life- prpSPrwr ~hall be a .. ailahll?' fflr immffiiatl?' U!le and rpartily rP<'Og"TIi7 .. Hhle hy Pf'J"i4)n~ not ha.ing- prf"-- .iolls in~tnl('tinn~ in it~ 1l~. The oral inflation oevice shall bp 10C'atPd ~o a:<: nor to interfe-r€' -with the faceor booy of thp w(>arf"r. To infiat(> thl?' life- prf>i't"ner ('ompartIDf'nt orally. it :-ohall be n~~rr only to blo-w
into thE' mouthpiPf'e of thE' oral inflation me-ans.
4.3.2 Oral Inflation "·alre. ThE" oral inflation
\'aj\-~ :-ohall ha.f' an "ppnin:: r~.;:.t11"(> of n.t') p.s.i.g. maximum whf'n no h:v'k P~';:'Un? b p~nt amI shall not lellk unnpr ha("k prf':<:$t1n;>;:. hf>rween Zl?'rfl p.:<:.i./!,. to
1(1 p.s.i..!!.
4.3.3 .1Iechankal Inflation. ){f'('haniral inflation of the prf":"f'rw'r :-ohall hf' al'("'nmp\j~hf'(l fly ('()~ unless it can be nemon:-otr:ltPf1 rhnt ~)mp othf'r means of infla-
tion is PQually :<:uitahll?'.
4.3.3_1 CO~ System. Onl?' rylinnpr shall bP pro.iderl to inflatf> fully (>n('h ftotntion ('Omparttnf>nt llf the life prf>S€'r\·l?'r. Earh inftation (jP\-if"P shall mnsist of an inflator a:-<"<:'(>lIlhly. Thf> inflator ~hall Pf'rmit insertion of a C'~·li.n(ter. me-eri.ng ~ifirnti(\n :.\[(L--C-00601 Type 1. into onl?' end and ~hall ('ontain the di~charg
ing de.ire in thp oppo:<:itp I?'nd. The nl?'l"ign of the inflator shall hf> ~u('h that thl?' in~tallM ('rlinner shall
hI?' punctur~-I wirh a trll'el nf rhf' I('w'r arm of not more than nfl: F. The inflator ~hall ha.e pro'isions fnr saferyin;!, thl?' II?"er. Thp le\'l?'r of each inflator
~hal1 he proyinPfI with a pull cord as...;;pmbly extending betwf'en 11~ an(I ~ jW'hE':" Tlf>\OW thl?' Pil!!f' of the life
pre~l?'t\"er. Thf> I?'n(1 flf thf' pull rorn as-.<:.f>mblr ~hall be attar-hed to a red pull knoh or tah whi('h ~hall he lI:<:Pfl tll arti.ate thf' inflator.
4.3.3.2 Inflator. The inflator shaH withstanrl a hydrostatil' pr{>S..~l1r{> of l})Ofl p.s.L tritho\1t neformation or leaka(!'l?'. The inflator ~hall n.)t leak 'Whf'n subjected to 2 and 40 p.s.L air pres:,.--ure. re::,.--PP<'ti\"ely.
with the lever at any position in its normal cycle of operation. The inflator shaH ha .. e an opening pressure of 25 to 3n p.s.i. and shall allow a minimum flow of 4: liters of air per minute at 40 p.s.i. inlet pressure. The inflator shall not leak when subjected to a negati .. e pressure of 12 inches of wate-r applied so as to reduce the seating spring pressure and with atmospheric pr(>ssure on the oppo~ite side.
4.4 Buoyancy. The life pres-ervpr (both compartments after inflation by the mechanical inflation means) shaH provide a minimum of 23 pounds of buoyanee in fresh water at 85 0 F.
5.0 Adaptability for Wearer.
5.1 Flotation Attitude. The life pr~er .. er shall support the wearer in an uprig-ht position face up not less than 15 deg-rees nor more than 30 degrees from the .. ertica1. The head shall be so supported that the trearer's face shall be out of the 'Water when he is un<,onscious or <'ompletely relaxed.
5.2 Donning Life Preserver. The life preserver
~hal1 be ea~ilr donned. by a person 'With a minimum amount of instruf'tion and shall be reasonably comfOl"table. It shall be capable of being donned by the wearer without assistance while in a sitting- pOSition. The liff> pre~l?'n-f>r shaH be so attached. to the wearer that it shall not slip off 'When jumping into the water from a hl?'ight of fi feet: ho'Wever. straps which pass between the wearE'r's legs are not p{'rmissible. The life presl?'rver shall not <'hafe the 'Wearer's legs, nP<'k fir re-stri('l brNlthing or hlood eir<'ulation.
5.3 Fastenings and Attachments. The meanS of Htta('hml:"nt of the lifp prese-rve-r by straps or fasteners shall hf' ("on\"enil?'ntly lo("atl?'rl anrl easily operated by thl?' tr(>nrel" undl?'r pmprgency lighting conditions. Therl?' ~hall hI?' a ml?'ans of adjustment of the life presen'er nttachin/!' mpans when inflated, to fit the wearer. Attaehml?'nt fastening devices shall develop at 1(>8st 80 pe-l'(,E'nt of the tensile strength of the straps t() whir-h th(>y are fastened without 10osl?'ning. Slipping or causing tearing of straps.
6.0 Child Life Preserver. All provisions of this stanrtnrd apply to child life presenE-rs with the ex· (,f'ption flf th{' ("hanges indicatE-d in the subparagraph of this parag-raph. For purposes of this standard, a rhilrl is ('nnsirll?'rf'rt to he in thE' ag-f' bra('kE't flf 2 to 6
yf>ar~.
6.t Flotation Attitude. The chilo liff' preserver shnll support thf' wl?'arl?'r in a f!l<'P up attitude so that the trf'nrer's fa ("I?' will he snpport(>o ahove the water linf' I?'vl?'n 'Whl?'n hI?' is 11ll('onf':cio1l8 or rompll?'tel~' relaxed.
6.2 Compartmentation. The child life preserver shall ha\'f' n minim\ltl1 of one ~asti,g-ht compartment.
6.3 Buoyancy. Thl?' r-hild Iifl?' prE'f':er,€'r shall providE' a minimum of 9 pounds of buoyancy in fresh watpr at 70 0 F.
6,4 Donning Life Preserrer. For the child life PI"{,f':f'r\'f'I" it if; a('('{>ptnbll?' to in('orporate straps whirh
pas~ hetwe-en the child's legs.
7.0 Survivor Locator Light.
7.1 Survivor Locator Light. Each life preserver shall be provided with a white survivor locator light complying with the provisions of this standard.
7.1.1 Survivor Locator Light Intensity. The survivor locator light shall provide a minimum effective intensity of 3 candles,in the direction specified in paragraph 7.1.2 for a period of 8 hours. Effective
intensity is that intensity which will give the same visual range as would a fixed light of the same color under identical conditions of operation. If a flashing light is used, effective intensity shall be computed from the following formula:
where:
Ott)dt j~, Ie= --=::-'~--
0.2+ ('1'2-T,)
le= effective Intensity (candles) I (t) ::::: instantaneous intensity as a function
of time T 2-T1 -= flash interval in seconds
7.1.2 Light Distribution. The light shall be mounted on the life preserver so as to provide illumination in all directions in the horizontal plane.
7.1.3 Attachment. The light shall Incorporate a device to enable it to be easily attached to and detached from the life preserver.
7.1.4 Waterproofing. The light shall be waterproofed to the extent that prolonged immerSion in fresh or salt water will not affect its operation.
7.1.5 Switch. Means for turning the light on and off shall be provided. Such means shall be readily available to the user.
8.0 Required Tests.
8.1 Initial Qualification Tests. The tests indicated in the following subparagraphs shall be conducted for initial qualification. These tests shall be conducted on a minimum of three samples. Each test article shall be representative of production units and shall be indivldually identified.
8.1.1 Buoyancy. When mechanically inflated and placed in fresh water at-a ·temperature of 70° F. the life preserver shall support a 20 pound steel weight without becoming .submerged. (In the case of a child life preserver, it shall support a 9 pound weight.)
8.1.2 Salt Spray. All metal parts shall operate satisfactorily and shall not corrode when subjected to a salt spray in accordance with Federal Specification QQ-M-151 for a period of 100 hours.
8.1.3 Rubber Goods. A sample of rubber goods shall be tested in accordance with specification FED-
STD-60l.
8.1.4 Textiles. A sample of textile goods shall be tested in accordance with specification CCC-T-191.
8.1.5 Survivor Locator Light Intensity. It shall be demonstrated that the survivor locator light provides a minimum effective intensity of 3 candles for a period of 8 hours.
8.1.6 Flame Resistance. All nonmetallic materials shall be tested for fhime resistance in accordance with Federal Specification CCC-T-191, Method 5906.
8.1.7 Pressure Test. Each compartment of each test sample life preserver shall withstand separately without failure an air pressure of 10 p.s.i.g. for 5 minutes.
8.1.8 Survivor Locator Light Watertightness. Each test sample light shall be submerged for a period of 8 hours in fresh water at 700 I( to such a depth that the highest point of the light is under a three foot head. After removal from the water, the light shall be examined to determine that no leakage has taken place.
8.2 Individual Performance. 8.2.1 Life Preserver. Each compartment of each life preserver manufactured shall be inflated with oil free air at 70° F. to a pressure of 2 p.s.i.g. After 11 12 hour period, the pressure loss shall not be in excess of 112 p.s.i.g.
8.2.2 Survivor Locator Light. Each survivor locator light shall be operated to demonstrate that the assembly is in an operating condition by lighting the
light with the means provided.
Whole text after this change
FEDERAL AVIATION AGENCY
FLIGHT STANDARDS SERVICE
[14 CFR 514]
[Regulatory Docket No. 1892; Notice No. 63–31]
TECHNICAL STANDARD ORDERS FOR AIRCRAFT MATERIALS, PARTS AND APPLIANCES
NOTICE OF PROPOSED RULE MAKING
Life Preservers—TSO-C13d
The Federal Aviation Agency has under considera- this notice may be changed in the light of comments tion a proposal to revise Section 514.23 of Part 514 received. All comments submitted will be available, of the Regulations of the Administrator by amend- both before and after the closing date for comments, ing the Technical Standard Order. This Technical in the Rules Docket for examination by interested Standard Order contains minimum performance re- persons. quirements for life preservers for use on civil aircraft This amendment is proposed under the authority of of the United States engaged in operation over water. Sections 313(a) and 601 of the Federal Aviation Act The amendment is proposed to clarify the existing of 1958 (72 Stat. 752, 775; 49 U.S.C. 1354(a), 1421). Technical Standard Order and to inelude standards In consideration of the foregoing it is proposed to for survivor locator lights. Flotation is the primary amend Part 514 by revising Section 514.23 to read and most important requirement for survival after as follows : escape from a ditched aircraft.
The possibility of § 514.23 Life preservers—TSO-C13d. survival is greatly increased if the survivor expedítiously boards one of the airplanes life rafts or a (a) Applicability. Minimum performance standrescue vessel. To insure and facilitate the location of ards are hereby established for life preservers (adult all survivors at night a means of illumination on the and child) including survivor locator lights which life preservers must be provided. A review of air- specifically are required to be approved for use on craft ditehings confirms that where lights on life civil aircraft of the United States.
New models of preservers were provided, persons in the water who life preservers manufactured on or after the effective might otherwise not have been saved were sighted date of this section shall meet the requirements speciand picked up in life rafts or rescue vessels. fied in Federal Aviation Standard "Life Preservers", Under this proposal the requirements would now dated July 26, 1963.1 Survivor locator lights which be incorporated into an FAA Standard instead of meet the requirements of this TSO may be mounted referring to an industry specification as was done in on previously approved life preservers. the previous TSO. The proposed TSO primarily in- (b) Markings. corporates those standards set forth in the previous (1) The life preservers shall be permanently TSO. The main substantive change is the new re- marked in accordance with the provisions of § 514.3 quirement for survivor locator lights.
Survivor loca- (d) except for the following: tor líghts which meet the standards prescribed in this (i) The weight of the life preserver assembly TSO may be mounted on previously approved life may be omitted; preservers. (ii) The date of manufacture of fabric (month Interested persons are invited to participate in the and year) shall be shown; and making of the proposed rule by submitting such writ- (iii) The intended user, i.e., "adult", "child", or "adult and child" shall be shown. ten data, views or arguments as they may desire. Communications should identify the regulatory docket (2) The survivor locator light shall be permanumber and be submitted in duplicate to the Federal nently marked in accordance with provisions of Aviation Agency, Office of the General Counsel: § 514.3(d) except for the following: Attention Rules Docket, Room A-103, 1711 New York (i) The weight of the survivor locator light Avenue, N.W., Washington, D.C. 20553.
AI1 commun- may be omitted. ications received on or before October 9, 1963, will be 1 Copies may be obtained upon request addressed to Pubconsidered by the Administrator before taking action lishing and Graphics Branch, Inquiry Section, HQ-440, Fedupon the proposed rule. The proposals contained in eral Aviation Agency, Washington, D.C. 20553
(c) Data requirements. In accordance with the provisions of § 514.2. as applicable. manufacturers of life preservers and the survivor locator lights shall furnish to the Chief, Engineering and Manufacturing Branch, Flight Standards Division, Federal Aviation Agency in the region in which the manufacturer is located, the following technical data :
Issued in Washington, D.C., on August 5, 1963.
(1) Six copies of an instruction manual deseribing the products and containing information for the maintenance, overhaul and installation of the life preserver and the survivor locator light : (2) Six copies of the necessary data detailing the mounting of the survivor locator light on the life preserver.
Acting pirector Flight Standards Service
JuLr 26, 1963
Federal Aviation Agency Standard
For
Life Preservers
1.0 Purpose. To establish minimum performance requirements for life preservers including survivor locator lights for use on civil aircraft of the United States engaged in operation over water. 1.1 Seope. This standard covers life preservers (adult and child and a combination of both) and survivor locator lights intended for the use of occupants of civil aireraft operating over water in the event of a ditching. Each life preserver shall be provided with a survivor locator light. Hereinafter, the term "life preserver" will include the survivor locator light as well as the life preserver. Special requirements for child life preservers are contained in paragraph 6.0 of this standard. 2.0 Applicable Specifcations. The following specifications, as applicable, shall form a part of this standard and shall include the latest revisions at the time of manufacture or, in the event that any are canceled or superseded, the revision of the specification last in effect shall apply. 2.1 Military Specifications.
MIL–C–5540 Adhesive Neoprene MIL-T-7807 Thread Nylon MIL-V-6077 Vest, Life Preserver, Pneumatic MIL-C-19002 Cloth and Cloth Tape, Coated, Pneumatic Life Preserver MIL-C-00601 Cylinder, Carbon Dioxide Filled (For Pneumatic Life Vests and Similar Uses) MII-W-21733 Webbing, Textile Nylon Pneumatic Life Preserver MIL-W-530 Webbing, Cotton, Natural or in Colors 2.2 Federal Specifications. FED-STD-601 Federal Test Method, Rubber sampling and testing CCC-T-191 Textile Test Methods QQ-M-151 Metals, general specification for inspection of FED-STD-595 Colors for ready mixed paints 2.3 American Society for Testing Materials. ASTM-D573-53 Method of test for accelerated aging of vulcanized rubber, by the oven method ASTM-D751-52T Methods of testing rubber coated fabrics 3.0 Materials and Workmanship. 3.1 Workmanship. Life preservers shall be constructed in a thorough workmanship manner. The finished items shall be free from any defects that might affect function or appearance.
3.2 Age of Nonmetallic Materials. All nonmetallic fabricated raw materials and components used in the manufacture of the life preservers shall have been manufactured not more than 12 months prior to the date of delivery of the finished product. 3.3 Coated Fabrics. All coated fabrics used in the manufacture of life preservers shall, except as otherwise provided, possess 90 percent of the physical properties called for under their applicable specifcations after these coated fabrics have been subjected to an accelerated aging test in accordance with ASTM-D573-53. 3.3.1 Flotation Chambers. Coated fabrics used for this application shall conform to the following minimum test specifications per ASTM-C751-52T: a. Tensile Strength—(Grab Test) Warp 210 lbs./inch minimum Fill 180 1bs./inch minimum b. Tear Strength—(Tongue or Strip Method— Raw Cloth) 10 x 10 lbs./inch minimum c. Permeability—Permeability to helium of not more than 5 liters per square meter per 24 hrs. at 77° F. (maximum) d. Coat Adhension—10.0 lbs./inch width 3.3.2 Seam Tape.
Tape used for the purpose of reinforcement of seams shall be suitable for the intended purpose. 3.4 Other Fabrics and Materials. 3.4.1 Webbing. Webbing used for the purpose of attaching the life preserver to the wearer shall be suitable for the intended purpose. 3.4.2 Thread. Thread used in the manufacture of life preservers shall be suitable for the intended purpose. 3.5 Seam Strength and Adhesives. Adhesives used in the manufacture of life preservers shall conform to appropriate specifications and shall develop minimum strength values specified therein. 3.6 Fungus Protection. All fabrics, threads and webbing used in the finished product which contain nutrient which will support fungus growth shall be suitably treated to prevent such growth. 3.7 Corrosion Protection. Metallic parts exposed to the atmosphere shall be corrosion resistant or protected against corrosion. 3.8 Flame Resistance. All material used in the life preserver shall be at least flame resistant.
3.9 Color. The life preserver color texcept the locator light )shall be Spanish Yellow. No. 70068. conforming to MIL—C-19002 or a color of equivalent high intensity. Note.—Crewmember life preservers. for the purpose of conspicuousness during an emergency. may be of a high intensity Red Color. 3.10 Temperature Limits. Materials used in the manufacture of life preservers and survivor locator lights shall not be affected by exposure to temperatures from − 40: F. to + 160: F.
4.0 Detail Requirements.
4.1 Rerersibility. The life preserver shall either be reversible or so designed as to preclude the probability of improper donning. If of the reversible type, the survivor locator light installation shal be suitable for its intended purpose when donned in either manner. 4.2 Compartmentation. The life preserver shall have a minimum of two gas-tight compartments.
43 Inflation. Each compartment of the life pre server shall have separate individual means for both mechanical and oral inflation.
4.3.1 Oral Inflation. Means for orally inflating the life preserver shall be available for immediate use and readily recognizable by persons not having previous instructions in its use. The oral inflation device shall be located so as not to interfere with the face or body of the wearer. To inflate the life preserver compartment orally. it shall be necessary only to blow into the mouthpiece of the oral inflation means. 4.32 Oral Infation Valre. The orat inftation valves shali have an opening pressure of 0.6 p.s.i.g. maximum when no back pressure is present and shall not leak under back pressures between zero p.s.i.g. to 1ù p.s.i.g. 4.3.3 Mechanical Inflation. Mechanical inflation of the preserver shall be accomplished by CO, unless it can be demonstrated that some other means of inflation is equally suitable.
4.3.3.1 CO. System. One cylinder shall be provided to inflate fully each flotation compartment of the life preserver. Each inflation device shall consist of an inflator assembly. The inflator shall permit insertion of a cylinder. meeting specification MIL-C-00601 Type 1. into one end and shall contain the discharging device in the opposite end. The design of the inflator shalt be such that the installed cylinder shall he punctured with a travel of the lever arm of not more than 9t F. The inflator shall have provisions for safetying the lever. The lever of each inflator shall he provided with a pull cord assembly extending between 11g and 3 inches below the edge of the life preserver. The end of the pull cord assembly shall be attached to a red pull knob or tab which shall be used to activate the inflator. 4.3.3.2 Infator. The inflator shall withstand a hydrostatie pressure of 1.500 p.s.i. without deformation or leakage. The inflator shall not leak when subjected to 2 and 40 p.s.i. air pressure. respectively.
with the lever at any position in its normal cycle of operation. The inflator shall have an opening pressure of 25 to 35 p.s.i. and shall allow a minimum flow of 4 liters of air per minute at 40 p.s.i. inlet pressure. The inflator shall not leak when subjected to a negative pressure of 12 inches of water applied so as to reduce the seating spring pressure and with atmospheric pressure on the opposite side. 4.4 Buoyancy. The life preserver (both compartments after inflation by the mechanical inflation means) shall provide a minimum of 23 pounds of buoyance in fresh water at 85° F.
5.0 Adaptability for Wearer. 5.1 Flotation Attitude. The life preserver shall support the wearer in an upright position face up not less than 15 degrees nor more than 30 degrees from the vertical. The head shall be so supported that the wearer's face shall be out of the water when he is unconscious or completely relaxed.
5.2 Donning Life Preserver. The life preserver shall be easily donned by a person with a minimum amount of instruction and shall be reasonably comfortable. It shall be capable of being donned by the wearer without assistance while in a sitting position. The life preserver shall be so attached to the wearer that it shall not slip off when jumping into the water from a height of 5 feet: however, straps which pass between the wearer's legs are not permissible. The life preserver shall not chafe the wearer's legs, neck or restriet breathing or blood circulation.
5.3 Fastenings and Attachments. The means of attachment of the life preserver by straps or fasteners shall be conveniently located and easily operated by the wearer under emergency lighting conditions. There shall be a means of adjustment of the life preserver attaching means when inflated, to fit the wearer. Attachment fastening devices shall develop at least 80 percent of the tensile strength of the straps to which they are fastened without loosening. slipping or causing tearing of straps.
6.0 Child Life Preserver. All provisions of this standard apply to child life preservers with the exception of the changes indicated in the subparagraph of this paragraph. For purposes of this standard, a child is considered to be in the age bracket of 2 to 6 years.
6.1 Flotation Attitude. The child life preserver shall support the wearer in a face up attitude so that the wearer's face will he supported above the water line even when he is unconscious or completely relaxed.
6.2 Compartmentation. The child life preserver shall have a minimum of one gastight compartment.
6.3 Buoyancy. The child life preserver shall provide a minimum of 9 pounds of buoyancy in fresh water at 70° F.
6.4 Donning Life Preserrer. For the child life preserver, it is acceptable to incorporate straps which pass between the child's legs.
7.0 Survivor Locator Light.
7.1 Survivor Locator Light. Each life preserver shall be provided with a white survivor locator light complying with the provisions of thís standard. 7.1.1 Survivor Locator Light Intensity. The survivor locator light shall provide a minimum effective intensity of 3 candles in the direction specified in paragraph 7.1.2 for a period of 8 hours. Effective intensity is that intensity which will give the same visual range as would a fixed light of the same color under identical conditions of operation. If a flashing light is used, effective intensity shall be computed from the following formula :
I(t) dt
Ie= 0.2+(T2−T1)
where: Ie=effective Intensity (candles) I(t) =instantaneous intensity as a function of time T2-T1= fiash interval in seconds
7.1.2 Light Distribution. The light shall be mounted on the life preserver so as to provide illumination in all directions in the horizontal plane. 7.1.3 Attachment. The light shall incorporate a device to enable it to be easily attached to and detached from the life preserver. 7.1.4 Waterproofing. The light shall be waterproofed to the extent that prolonged immersion in fresh or salt water will not affect its operation. 7.1.5 Switch. Means for turning the light on and off shall be provided. Such means shall be readily available to the user. 8.0 Required Tests.
8.1 Initial Qualification Tests. The tests indicated in the following subparagraphs shall be conducted for initial qualification. These tests shall be conducted on a minimum of three samples. Each test article shall be representative of production units and shall be individually identified.
8.1.1 Buoyancy. When mechanically inflated and placed in fresh water at-a·temperature of 70° F. the life preserver shall support a 20 pound steel weight without becoming submerged. (In the case of a child life preserver, it shall support a 9 pound weight. 8.1.2 Salt Spray. All metal parts shall operate satisfactorily and shall not corrode when subjected to a salt spray in accordance with Federal Specification QQ–M–151 for a period of 100 hours. 8.1.3 Rubber Goods. A sample of rubber goods shall be tested in accordance with specification FED- STD-601. 8.1.4 Textiles. A sample of textile goods shall be tested in accordance with specification CCC-T-191. 8.1.5 Survivor Locator Light Intensity. It shall be demonstrated that the survivor locator líght provides a minimum effective intensity of 3 candles for a period of 8 hours. 8.1.6 Flame Resistance. All nonmetallic materials shall be tested for flame resistance in accordance with Federal Specification CCC-T-191, Method 5906. 8.1.7 Pressure Test.
Each compartment of each test sample life preserver shall withstand separately without failure an air pressure of 10 p.s.i.g. for 5 minutes. 8.1.8 Survivor Locator Light Watertightness. Each test sample light shall be submerged for a period of 8 hours in fresh water at 70° F. to such a depth that the highest point of the light is under a three foot head. After removal from the water, the light shall be examined to determine that no leakage has taken place. 8.2 Individual Performance. 8.2.1 Life Preserver. Each compartment of each life preserver manufactured shall be inflated with oil free air at 70° F. to a pressure of 2 p.s.i.g. After a 12 hour period, the pressure loss shall not be in excess of 1⁄2 p.s.i.g. 8.2.2 Survivor Locator Light. Each survivor locator light shall be operated to demonstrate that the assembly is in an operating condition by lighting the light with the means provided.
3316—64