8-153 9

15-0 CIVIL AERONAUTICS AUTHCRITY WASHINGTON, D. C.

NOTIOE

Redistribution of attached Amendment No. 20 of the

Civil Air Regulations has been made in order to correct

errors discovered in some of tho copies previously circu-

lated. All copies initially distributed were not in

orror, but in order to make sure that you have the correct

information, please substitute the attached for the one

you have.

Regulations Serial Number 30

THE UNITED STATES OF AMERICA CIVIL AERONAUTICS AUTHORITY WASHINGTON, D. C.

At a session of the Civil Aeronautics Authority held at its office in Washington, D. C. on the 25th day of July, i939.

Acting pursuant to the authority vested in 't by the Civil Aeronautics

Act of 1938, particularly sections 205(a) and 60l(a) of said Act, and

finding that its action is desirable in the public interest and is necessary

to carry out the provisions of, and to exercise and perform its powers

and duties under said Act, the Civil Aeronautics Authority hereby amends

the Civil Air Regulations as follows:

AMENDMENT NO. 20 OF THE CIVIL AIR POSITION LIGHTS REGULATIONS

AMENDMENT NO. 20 OF THE CIVIL AIR POSITION LIGHTS REGULATIONS

Effective August 15, 1939, Part 15 of the Civil Air Regulations is

amended as follows:

l. By striking the word "equipment" in tho title of section l5.2

and inserting in lieu thereof the word "appliances".

2. By striking section 15.20 and inserting in lieu thereof the

following new section:

"15.20 Position lights

"15.200 General provisions. Position ligl.s prescribed in Part 04

of the Civil Air Regulations, in order to be certificated, shall be so

constructed and capable of being so mounted as to comply with the regula-

tions hereinafter prescribed."

"15.2000 A request for certification and such supporting data as

may be prescribed herein shall be accompanied by a complete set of lights

described in the data, Such data shall include a copy of the instructions

for the mounting of the lights in aircraft as furnished by the light manu-

facturer to purchasers."

"15.200l As the forward (right and left) lights are complementary

they will be certificated as a unit. The rear (tail) light will be cer-

tificated as a separate unit."

"15.2002 Forward lights are classified as follows:

(a) Standard forward position lights.

(b) Air Carrier forward position lights.

(c) Auxiliary position lights."

"15.201 Light distribution reguirements. (See CAAM 15 for diagrans.)"

"15.2010 Definitions. Three dihedral angles hereinafter referred to

as dihedral angle L, dihedral angle R, and dihedral angle A are defined as

follows: dihedral angle L is formed by the intersection of two vertical

planes, one passing through the forward axis of the light unit, as defined

in the mounting instructions, and the other at an angle of ll0 degrees to

the first, measured to the left when looking away from the unit; dihedral

angle R is formed by the intersection of two vertical planes, one passing

through the forward axis of the light unit, as defined in the mounting

instructions, and the other at an angle of ll0 degrees to the first measured

to the right when looking away from the unit; and dihedral angle A (aft)

is formed by the intersection of two vertical planes maling dihedral angles

of 70 degrees to the left and 70 degrees to the right, respectively, of a

vertical plane passing through the rear axis of the light unit, as defined

in the mounting instructions. Each dihedral angle shall be understood to

include the bounding planes as well as the space between the planes."

"15.20ll Standord forword position lights, Ecch stonderd forwerd

position light shall heve en intensity of not lcss than 3 cendlcs in all

dircctions in dihodrel anglo L for thc lcft light and in dihodrel anglo R

for the right light. Within theso dihodrel anglos, rcspcctivoly, tho in-

tonsity in all diroctions shcll equcl or cxcccd the minimm veluos given

in Tcblc I cccording to thc anglo botweon the direction of mocsurcnent and

tho forward exis of the unit.

Tcblc I

Minimum pornissiblc intonsitics in any plano through the forwrd cxis of tho unit

At anglos fron forwerd axis not oxccoding Intonsity

60 dogrcos 4 cendlcs 30 dogrcos 8 cendles

In all dircctions in dihcdrel anglc R for thc lcft light and in dihedrel

anglo L for the right light, a tolcrence of 10 dcgroos will bo allowed in

which tho intonsity of those lights shell bo rcduced to not over 2 cendlcs.

In th.so same dircctions c furthor tolorencc of an additional 10 dogrcos

will bo allowed in which the intonsity shell bo rcduced to not more than

0.5 candlc. In cll directions in dihedrel englo 4 a tolcrencc of 10 degrocs

will bo cllowed in vhich tho intonsity of thcsc lights shell bo rcduced to

a mexirun intonsity of 0.5 candle. In all dircctions outsido tho spccificd

dihodrel angle and thc allowed toloranco anglos for ach unit, tho stray

light intonsity shall not cxcoed 0.5 candlo."

"15.2012 fir Cerricr forward position lights. Each cir ccrrier for-

ward position light shall have en intensity of not loss thcn 3 candles in

all dircctions in dihedrel angle L for thc loft light and in dihedrel angle

R for thc right light. Within these dihodrel anglos, respectively, the

intensity in all cirections shall equal or exceed the minimum values,given

in Table II according to the angle between the diraction of measurement

and the forward axis of the unit.

Table II Kinimum pemissible intensities in any plane through the forward axis o? the unit

At angles fron forward Intensity axis not exceeding

60 Degrees 5 Candles 30 Degrees 10 Candles 20 Defrees 20 Candles 15 Degrees 30 Candles 10 Degrees 35 Candles 5 Degrees 40 Candles

Within the sane dihedrcl angles the intensities in the horizontal plane

shall equal or exceed the rinimm vlues given in Table III according to

the angle between the direction of measurement and the forward axis of the

unit.

Table III Hinimum permissible intensities in the horizontal plane thrugh the forward axis of the unit

At angles froz forvard Intensity axis not exceeding

80 Degrecs 5 Candles 40 Degrees 10 Candles 30 Dorees 20 Candles 20 Deprees 30 Candles 10 Degrees 40 Candles

In all directions in dihedral angle R for the left light and in dihedral

andle L for the right light, a tolerance .of 10 degrees will be allowed in

which the intensity of these lights shall be reduced to not over l0 candles.

In these same directions a further tolerance of an addi.tional 10 degrees

will be allowed in :hich the intensity shall be reduced to not moro than

1 candle. In all directions in dihedral angle A a tolerance of 10 degrees

will be allowed in which the intensity of those lights shall be reduced

to not more than 1 candle. In all directions outside the specified

dihedral angle and the allowed tolerance angles for cach unit, the stray

light intensity shall not exceed 1 candle."

"15.20l3 Auxiliory forward position lights. Each auxiliary forward

position light shall have an intensity of not less than 20 candles in all

directions not excceding 30 degrces of the forward axis of the unit, measur-

ed in dihedral angle L for the left unit and in dihedral angle R for the

right unit. Within the afore-described angles the intensity in all direct-

ions shall equal or exceed the minimn values given in Table IV according

to the angle between the diroction of the measurement and the forward axis

of the unit.

Table IV.

Minimun permissible intensities in any plane through the forward axis of the unit

At angles fron forward axis not excecding Intensity

20 Begrecs 30 Candles 10 Degrees 40 Candlcs

20 Begrecs 30 Candles 10 Degrees 40 Candlcs

In all directions in dihodral angle R for the left light and in dihedral

angle L for the right light, a tolcrance of l0 degrees will bo allowed in

which tho intensity of those lights shall be reduced to not over 8 candles.

In those same directions a further tolerance of an additional 10 degrees will

be allowed in which the intensity shall be reduced to not nore than 0.5

candle. In all directions in dihedral anglc A thc maximum intensity shall

be less than 0.5 candle. In all diroctions outside tho specified dihedral

angle and the allowed tolcrarce angles for each unit, the stray light in-

tensity shall not exceed 0.5 candle."

"15.20l4 Pear pcsitier liihts. Fach rear pcsition light. shall. have

an intensity of not Less than 4 contles in cihcarel angle i. Within this

dihedral angle the intensity ir. all diroctions not xcceding 70 degrees

fror. th: reor axis of thc urit, shall be not ies. than 8 cendles. In all

directiors in cihccral angle L and in dihceral angle R, a tolcrance of 20

deerees will be allowed in which the intensity of this light rust be re-

duced to a maximu stray light intensity of 1 candle. In all directions

outside the spccified dihedral angl, and the allowed toleranct angles, the

stray light intensity shall not excecd 1. canle."

"15.202 Coler. All lcft forward lights shall bo aviation red, all

right forward lights shall be aviation froon, and all rcar lights shall be

aviation white. These cclors are dofined as follcws:

(a) Aviation red is a color having thc fcllowing ICI chronaticity coordinates:

y is not roater than 0.335 ard z is not εreater than 0.002

(b) Aviatien green is a colcr havirs the following ICI chromaticity ceordinates:

x is not reater than 0.440 - 0.320y x is not reate than y - 0.170 end y is not less than 0.390 - 0.170x

(c) Aviation white is a color having tho fcllowing ICI chrcmaticity ccordinates:

x is not less than 0.350 x is ret greater than 0.540 y - is not numerically Ereat er than 0.01 y beinc the J coorcincte of the Planckian radiator for 0 which xC = x." "15.203 Light covers. Tha lanp and reflectors shall bc protected by

a cover which shall be f non-corbustible naterial. and so constructed that

it will net change color or shape, or clcud, or suffer any considerable

7 loss of transmission in ncrmal use.

Tho coloring of those portions which ere intended to transnit light shall be coapletely dliffused through the

·material."

(SmL)

By tho Authority: /s/ Paul J. Frizzell Pcul J. Frizzoll, Secrctary.