Radar Vectors
RegulationText changedNov 18, 2026

Appendix E to Part 420 Tables for Explosive Site Plan

Text changed: 8 of 10 passages.

Date
Nov 18, 2026
Recorded
Nov 18, 2026
Passages
8 of 10 changed
Paragraphs
34 added or rewritten, 26 removed or rewritten

Read the current text Official source ↗

What changed in the text

Key: [removed: removed words] are struck through; [added: added words] are underlined. Each changed paragraph is labelled in the margin.

  1. Changed

    [removed: NEW(lbs.)][added: Table] [removed: |][added: E-1—Division] [removed: Distance][added: 1.1 Distances] to [removed: public][added: a] [removed: area(ft)][added: Public] [removed: 1][added: Area] [removed: 2][added: or] [removed: |][added: Public] [removed: Distance][added: Traffic] [removed: to][added: Route] [removed: public][added: for] [removed: traffic][added: NEW] [removed: route][added: ≤450] [removed: distance(ft) 2][added: lbs]

  2. Added

    [added: NEW (lbs.) | Distance to public area (ft) 1 2 | Distance to public traffic route distance (ft) 2]

  3. ≤0.5 | 236 | 142

  4. 0.7 | 263 | 158

  5. 24 unchanged paragraphs
  6. 236 ft ≤d <658 ft: NEW = exp [(d/79.2)-3.678]

  7. 658 ft ≤d <1250 ft: NEW = exp [(d/389) + 2.914]

  8. Changed

    NEW is in lbs; d is in ft; exp[x] is [removed: ex.][added: e x.]

  9. 2 The public traffic route distance is 60 percent of the distance to a public area.

  10. Changed

    [removed: NEW][added: Table] [removed: (lbs)][added: E-2—Division] [removed: |][added: 1.1] Distance to [removed: public][added: Public] [removed: area(ft)][added: Area] [removed: 1][added: and] [removed: |][added: Public] [removed: Distance][added: Traffic] [removed: to][added: Route] [removed: public][added: for] [removed: traffic][added: NEW] [removed: route(ft)][added: >450 lbs]

  11. Added

    [added: NEW (lbs) | Distance to public area (ft) 1 | Distance to public traffic route (ft)]

  12. 450 lbs<NEW ≤30,000 lbs | 1,250 | 750.

  13. 30,000 lbs<NEW ≤100,000 lbs | 40*NEW 1/3 | 0.60*(Distance to Public Area).

  14. 100,000 lbs<NEW ≤250,000 lbs | 2.42*NEW 0.577 | 0.60*(Distance to Public Area).

  15. 250,000 lbs<NEW | 50*NEW 1/3 | 0.60*(Distance to Public Area).

  16. 1 To calculate NEW from distance d to a public area:

  17. Changed

    1, 243 ft<d ≤1,857 ft: NEW = [removed: d3/64,000][added: d 3/64,000]

  18. 1, 857 ft<d ≤3,150 ft: NEW = 0.2162 * d 1.7331

  19. Changed

    3,150 ft<d: NEW = [removed: d3/125,000][added: d 3/125,000]

  20. NEW is in lbs; d is in ft.

  21. Changed

    [removed: NEW(lbs)][added: Table] [removed: |][added: E-3—Division] [removed: IntralineDistance(ft)][added: 1.1 Intraline Distances 1 2 3]

  22. Added

    [added: NEW (lbs) | Intraline Distance (ft)]

  23. 50 | 66

  24. 70 | 74

  25. 31 unchanged paragraphs
  26. NEW is in pounds; d is in feet

  27. 2 To calculate maximum NEW from given intraline distance d:

  28. Changed

    NEW = [removed: d3/5,832][added: d 3/5,832]

  29. NEW is in pounds; d is in feet.

  30. 3 NEW values of more than 500,000 lbs only apply to liquid propellants with TNT equivalents equal to those NEW values. The intraline distances for NEW greater than 500,000 pounds do not apply to division 1.1 explosives.

  31. Removed

    [removed: NEW (lbs) | Distance to public area or public traffic route (ft) 1 | Intralinedistance (ft) 2]

  32. Added

    [added: Table E-4—Division 1.3 Separation Distances]

  33. Added

    [added: NEW (lbs) | Distance to public area or public traffic route (ft) 1 | Intraline distance (ft) 2]

  34. ≤1000 | 75 | 50

  35. 1,500 | 82 | 56

  36. 21 unchanged paragraphs
  37. d= 75 ft

  38. 1,000 lbs<NEW ≤96,000 lbs

  39. Changed

    d = exp[2.47 + 0.2368*(ln(NEW)) + [removed: 0.00384*(ln(NEW))2]][added: 0.00384*(ln(NEW)) 2]]

  40. 96,000 lbs<NEW ≤1,000,000 lbs

  41. Changed

    d = exp[7.2297−0.5984*(ln(NEW)) + [removed: 0.04046*(ln(NEW))2]][added: 0.04046*(ln(NEW)) 2]]

  42. NEW >1,000,000 lbs

  43. d = 8*NEW 1/3

  44. Changed

    NEW is in pounds; d is in feet; exp[x] is [removed: ex;][added: e x;] ln is natural logarithm.

  45. To calculate NEW from distance d to a public area or traffic route (noting that d cannot be less than 75 ft):

  46. 0 ≤d <75 ft:

  47. 4 unchanged paragraphs
  48. NEW = exp[7.395 + (−124.002 + 24.716*(ln(d)))1/2]

  49. 800 ft<d

  50. Changed

    NEW = [removed: d3/512][added: d 3/512]

  51. Changed

    NEW is in lbs; d is in ft; exp[x] is [removed: ex;][added: e x;] ln is natural logarithm

  52. 2 To calculate intraline distance d from NEW:

  53. NEW ≤1,000 lbs

  54. d = 50 ft

  55. 1,000 lbs<NEW ≤84,000 lbs

  56. Changed

    d = exp[2.0325 + 0.2488*(ln(NEW)) + 0.00313* [removed: (ln(NEW))2]][added: (ln(NEW)) 2]]

  57. 84,000 lbs<NEW ≤1,000,000 lbs

  58. Changed

    d= exp[4.338−0.1695*(ln(NEW)) + [removed: 0.0221*(ln(NEW))2]][added: 0.0221*(ln(NEW)) 2]]

  59. 1,000,000 lbs<NEW

  60. d = 5*NEW 1/3

  61. Changed

    NEW is in pounds; d is in feet; exp[x] is [removed: ex;][added: e x;] ln is natural logarithm

  62. To calculate NEW from an intraline distance d:

  63. 0 ≤d <50 ft:

  64. 4 unchanged paragraphs
  65. NEW = exp[3.834 + (−181.58 + 45.249*(ln(d)))1/2]

  66. 500 ft≤d

  67. Changed

    NEW = [removed: d3/125][added: d 3/125]

  68. Changed

    NEW is in pounds; d is in feet; exp[x] is [removed: ex;][added: e x;] ln is natural logarithm

  69. Added

    [added: Table E-5—Energetic Liquid Explosive Equivalents 1 2 3]

  70. Energetic liquids | TNT Equivalence | TNT Equivalence

  71. | Static Test Stands | Launch Pads.

  72. LO2/LH2 | See Note 3 | See Note 3.

  73. LO2/LH2 + LO2/RP-1 | Sum of (see Note 3 for LO2/LH2) + (10% for LO2/RP1) | Sum of (see Note 3 for LO2/LH2) + (20% for LO2/RP1).

  74. Changed

    LO2/RP-1 | 10% | 20% up to 500,000 [removed: lbsPlus][added: lbs Plus] 10% over 500,000 lbs

  75. IRFNA/UDMH | 10% | 10%.

  76. Changed

    [removed: N2 04/UDMH][added: N204/UDMH] + [removed: N2 H4][added: N2H4] | 5% | 10%.

  77. 1 A launch site operator must use the percentage factors of table E-5 to determine TNT equivalencies of incompatible energetic liquids that are within an intraline distance of each other.

  78. 2 A launch site operator may substitute the following energetic liquids to determine TNT equivalency under this table as follows:

  79. Alcohols or other hydrocarbon for RP-1

  80. Changed

    [removed: H2 O2][added: H2O2] for LO2 (only when [removed: H2 O2][added: H2O2] is in combination with RP-1 or equivalent hydrocarbon fuel)

  81. Changed

    MMH for [removed: N2 H4,][added: N2H4,] UDMH, or combinations of the two.

  82. 3 TNT equivalency for LO2/LH2 is the larger of:

  83. Changed

    (a) TNT equivalency of [removed: 8*W2/3,][added: 8*W 2/3,] where W is the weight of LO2/LH2 in lbs; or

  84. (b) 14 percent of the LO2/LH2 weight.

  85. Removed

    [removed: Item | Density(lb/gal) | Temperature( °F)]

  86. Added

    [added: Table E-6—Factors To Use When Converting Energetic Liquid Densities]

  87. Added

    [added: Item | Density (lb/gal) | Temperature ( °F)]

  88. Ethyl alcohol | 6.6 | 68

  89. Hydrazine | 8.4 | 68

  90. 5 unchanged paragraphs
  91. UDMH | 6.6 | 68

  92. UDMH/Hydrazine | 7.5 | 68

  93. Removed

    [removed: Quantity(lbs) | Intraline distance or distance to public area or distance to public traffic route(ft)]

  94. Added

    [added: Table E-7—Separation Distance Criteria for Storage of Hydrogen Peroxide in Concentrations of More than 91 Percent 1 2]

  95. Added

    [added: Quantity (lbs) | Intraline distance or distance to public area or distance to public traffic route (ft)]

  96. 10,000 | 510

  97. 15,000 | 592

  98. 13 unchanged paragraphs
  99. To calculate weight of hydrogen peroxide from a distance d:

  100. d >75 ft

  101. Changed

    W = exp[−134.286 + 71.998*(ln(d)) [removed: −12.363*(ln(d))2][added: −12.363*(ln(d)) 2] + [removed: 0.7229*(ln(d))3]][added: 0.7229*(ln(d)) 3]]

  102. Added

    [added: Table E-8—Separation Distance Criteria for Storage of Liquid Hydrogen and Bulk Quantities of Hydrazine]

  103. Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids | Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids

  104. Over | Not Over | Distance in feet | Distance in feet | Over | Not Over | Distance in feet | Distance in feet

  105. 29 unchanged paragraphs
Whole text before this change

NEW(lbs.) | Distance to public area(ft) 1 2 | Distance to public traffic route distance(ft) 2

≤0.5 | 236 | 142

0.7 | 263 | 158

1 | 291 | 175

2 | 346 | 208

3 | 378 | 227

5 | 419 | 251

7 | 445 | 267

10 | 474 | 284

15 | 506 | 304

20 | 529 | 317

30 | 561 | 337

31 | 563 | 338

50 | 601 | 361

70 | 628 | 377

100 | 658 | 395

150 | 815 | 489

200 | 927 | 556

300 | 1085 | 651

450 | 1243 | 746

1 To calculate distance d to a public area from NEW:

NEW ≤0.5 lbs: d = 236

0.5 lbs <NEW <100 lbs: d = 291.3 + [79.2 *ln(NEW)]

100 lbs ≤NEW ≤450 lbs: d = −1133.9 + [389 *ln(NEW)]

NEW is in lbs; d is in ft; ln is natural logarithm.

To calculate maximum NEW given distance d (noting that d can never be less than 236 ft):

0 ≤d <236 ft: Not allowed (d cannot be less than 236 ft)

236 ft ≤d <658 ft: NEW = exp [(d/79.2)-3.678]

658 ft ≤d <1250 ft: NEW = exp [(d/389) + 2.914]

NEW is in lbs; d is in ft; exp[x] is ex.

2 The public traffic route distance is 60 percent of the distance to a public area.

NEW (lbs) | Distance to public area(ft) 1 | Distance to public traffic route(ft)

450 lbs<NEW ≤30,000 lbs | 1,250 | 750.

30,000 lbs<NEW ≤100,000 lbs | 40*NEW 1/3 | 0.60*(Distance to Public Area).

100,000 lbs<NEW ≤250,000 lbs | 2.42*NEW 0.577 | 0.60*(Distance to Public Area).

250,000 lbs<NEW | 50*NEW 1/3 | 0.60*(Distance to Public Area).

1 To calculate NEW from distance d to a public area:

1, 243 ft<d ≤1,857 ft: NEW = d3/64,000

1, 857 ft<d ≤3,150 ft: NEW = 0.2162 * d 1.7331

3,150 ft<d: NEW = d3/125,000

NEW is in lbs; d is in ft.

NEW(lbs) | IntralineDistance(ft)

50 | 66

70 | 74

100 | 84

150 | 96

200 | 105

300 | 120

500 | 143

700 | 160

1,000 | 180

1,500 | 206

2,000 | 227

3,000 | 260

5,000 | 308

7,000 | 344

10,000 | 388

15,000 | 444

20,000 | 489

30,000 | 559

50,000 | 663

70,000 | 742

100,000 | 835

150,000 | 956

200,000 | 1,053

300,000 | 1,205

500,000 3 | 1,429

700,000 | 1,598

1,000,000 | 1,800

1,500,000 | 2,060

2,000,000 | 2,268

3,000,000 | 2,596

5,000,000 | 3,078

1 To calculate intraline distance d from NEW:

d = 18*NEW 1/3

NEW is in pounds; d is in feet

2 To calculate maximum NEW from given intraline distance d:

NEW = d3/5,832

NEW is in pounds; d is in feet.

3 NEW values of more than 500,000 lbs only apply to liquid propellants with TNT equivalents equal to those NEW values. The intraline distances for NEW greater than 500,000 pounds do not apply to division 1.1 explosives.

NEW (lbs) | Distance to public area or public traffic route (ft) 1 | Intralinedistance (ft) 2

≤1000 | 75 | 50

1,500 | 82 | 56

2,000 | 89 | 61

3,000 | 101 | 68

5,000 | 117 | 80

7,000 | 130 | 88

10,000 | 145 | 98

15,000 | 164 | 112

20,000 | 180 | 122

30,000 | 204 | 138

50,000 | 240 | 163

70,000 | 268 | 181

100,000 | 300 | 204

150,000 | 346 | 234

200,000 | 385 | 260

300,000 | 454 | 303

500,000 | 569 | 372

700,000 | 668 | 428

1,000,000 | 800 | 500

1,500,000 | 936 | 577

2,000,000 | 1,008 | 630

1 To calculate distance d to a public area or traffic route from NEW:

NEW ≤1,000lbs

d= 75 ft

1,000 lbs<NEW ≤96,000 lbs

d = exp[2.47 + 0.2368*(ln(NEW)) + 0.00384*(ln(NEW))2]

96,000 lbs<NEW ≤1,000,000 lbs

d = exp[7.2297−0.5984*(ln(NEW)) + 0.04046*(ln(NEW))2]

NEW >1,000,000 lbs

d = 8*NEW 1/3

NEW is in pounds; d is in feet; exp[x] is ex; ln is natural logarithm.

To calculate NEW from distance d to a public area or traffic route (noting that d cannot be less than 75 ft):

0 ≤d <75 ft:

Not allowed (d cannot be less than 75 ft) for NEW ≤1000 lbs

75 ft ≤d≤296 ft

NEW = exp[−30.833 + (307.465 + 260.417*(ln(d)))1/2]

296 ft<d≤800 ft

NEW = exp[7.395 + (−124.002 + 24.716*(ln(d)))1/2]

800 ft<d

NEW = d3/512

NEW is in lbs; d is in ft; exp[x] is ex; ln is natural logarithm

2 To calculate intraline distance d from NEW:

NEW ≤1,000 lbs

d = 50 ft

1,000 lbs<NEW ≤84,000 lbs

d = exp[2.0325 + 0.2488*(ln(NEW)) + 0.00313* (ln(NEW))2]

84,000 lbs<NEW ≤1,000,000 lbs

d= exp[4.338−0.1695*(ln(NEW)) + 0.0221*(ln(NEW))2]

1,000,000 lbs<NEW

d = 5*NEW 1/3

NEW is in pounds; d is in feet; exp[x] is ex; ln is natural logarithm

To calculate NEW from an intraline distance d:

0 ≤d <50 ft:

Not allowed (d cannot be less than 50 ft) for NEW ≤1000 lbs

50 ft ≤d≤192 ft

NEW = exp[−39.744 + (930.257 + 319.49*(ln(d)))1/2]

192 ft<d≤500 ft

NEW = exp[3.834 + (−181.58 + 45.249*(ln(d)))1/2]

500 ft≤d

NEW = d3/125

NEW is in pounds; d is in feet; exp[x] is ex; ln is natural logarithm

Energetic liquids | TNT Equivalence | TNT Equivalence

| Static Test Stands | Launch Pads.

LO2/LH2 | See Note 3 | See Note 3.

LO2/LH2 + LO2/RP-1 | Sum of (see Note 3 for LO2/LH2) + (10% for LO2/RP1) | Sum of (see Note 3 for LO2/LH2) + (20% for LO2/RP1).

LO2/RP-1 | 10% | 20% up to 500,000 lbsPlus 10% over 500,000 lbs

IRFNA/UDMH | 10% | 10%.

N2 04/UDMH + N2 H4 | 5% | 10%.

1 A launch site operator must use the percentage factors of table E-5 to determine TNT equivalencies of incompatible energetic liquids that are within an intraline distance of each other.

2 A launch site operator may substitute the following energetic liquids to determine TNT equivalency under this table as follows:

Alcohols or other hydrocarbon for RP-1

H2 O2 for LO2 (only when H2 O2 is in combination with RP-1 or equivalent hydrocarbon fuel)

MMH for N2 H4, UDMH, or combinations of the two.

3 TNT equivalency for LO2/LH2 is the larger of:

(a) TNT equivalency of 8*W2/3, where W is the weight of LO2/LH2 in lbs; or

(b) 14 percent of the LO2/LH2 weight.

Item | Density(lb/gal) | Temperature( °F)

Ethyl alcohol | 6.6 | 68

Hydrazine | 8.4 | 68

Hydrogen peroxide (90 percent) | 11.6 | 68

Liquid hydrogen | 0.59 | −423

Liquid oxygen | 9.5 | −297

Red fuming nitric acid (IRFNA) | 12.9 | 77

RP-1 | 6.8 | 68

UDMH | 6.6 | 68

UDMH/Hydrazine | 7.5 | 68

Quantity(lbs) | Intraline distance or distance to public area or distance to public traffic route(ft)

10,000 | 510

15,000 | 592

20,000 | 651

30,000 | 746

50,000 | 884

70,000 | 989

100,000 | 1114

150,000 | 1275

200,000 | 1404

300,000 | 1607

500,000 | 1905

1 Multiple tanks containing hydrogen peroxide in concentrations of greater than 91 percent may be located at distances less than those required by table E-7; however, if the tanks are not separated from each other by 10 percent of the distance specified for the largest tank, then the launch site operator must use the total contents of all tanks to calculate each intraline distance and the distance to each public area and each public traffic route.

2 A launch site operator may use the equations below to determine permissible distance or quantity between the entries of table E-7:

W >10,000 lbs Distance = 24 * W1/3

Where Distance is in ft and W is in lbs.

To calculate weight of hydrogen peroxide from a distance d:

d >75 ft

W = exp[−134.286 + 71.998*(ln(d)) −12.363*(ln(d))2 + 0.7229*(ln(d))3]

Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids | Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids

Over | Not Over | Distance in feet | Distance in feet | Over | Not Over | Distance in feet | Distance in feet

| | | | 60,000 | 70,000 | 1,200 | 130

100 | 200 | 600 | 35 | 70,000 | 80,000 | 1,200 | 130

200 | 300 | 600 | 40 | 80,000 | 90,000 | 1,200 | 135

300 | 400 | 600 | 45 | 90,000 | 100,000 | 1,200 | 135

400 | 500 | 600 | 50 | 100,000 | 125,000 | 1,800 | 140

500 | 600 | 600 | 50 | 125,000 | 150,000 | 1,800 | 145

600 | 700 | 600 | 55 | 150,000 | 175,000 | 1,800 | 150

700 | 800 | 600 | 55 | 175,000 | 200,000 | 1,800 | 155

800 | 900 | 600 | 60 | 200,000 | 250,000 | 1,800 | 160

900 | 1,000 | 600 | 60 | 250,000 | 300,000 | 1,800 | 165

1,000 | 2,000 | 600 | 65 | 300,000 | 350,000 | 1,800 | 170

2,000 | 3,000 | 600 | 70 | 350,000

| 400,000 | 1,800 | 175

3,000 | 4,000 | 600 | 75 | 400,000 | 450,000 | 1,800 | 180

4,000 | 5,000 | 600 | 80 | 450,000 | 500,000 | 1,800 | 180

5,000 | 6,000 | 600 | 80 | 500,000 | 600,000 | 1,800 | 185

6,000 | 7,000 | 600 | 85 | 600,000 | 700,000 | 1,800 | 190

7,000 | 8,000 | 600 | 85 | 700,000 | 800,000 | 1,800 | 195

8,000 | 9,000 | 600 | 90 | 800,000 | 900,000 | 1,800 | 200

9,000 | 10,000 | 600 | 90 | 900,000 | 1,000,000 | 1,800 | 205

10,000 | 15,000 | 1,200 | 95 | 1,000,000 | 2,000,000 | 1,800 | 235

15,000 | 20,000 | 1,200 | 100 | 2,000,000 | 3,000,000 | 1,800 | 255

20,000 | 25,000 | 1,200 | 105 | 3,000,000 | 4,000,000 | 1,800 | 265

25,000 | 30,000 | 1,200 | 110 | 4,000,000 | 5,000,000 | 1,800 | 275

30,000 | 35,000 | 1,200 | 110 | 5,000,000 | 6,000,000 | 1,800 | 285

35,000 | 40,000 | 1,200 | 115 | 6,000,000 | 7,000,000 | 1,800 | 295

40,000 | 45,000 | 1,200 | 120 | 7,000,000 | 8,000,000 | 1,800 | 300

45,000 | 50,000 | 1,200 | 120 | 8,000,000 | 9,000,000 | 1,800 | 305

50,000 | 60,000 | 1,200 | 125 | 9,000,000 | 10,000,000 | 1,800 | 310

Whole text after this change

Table E-1—Division 1.1 Distances to a Public Area or Public Traffic Route for NEW ≤450 lbs

NEW (lbs.) | Distance to public area (ft) 1 2 | Distance to public traffic route distance (ft) 2

≤0.5 | 236 | 142

0.7 | 263 | 158

1 | 291 | 175

2 | 346 | 208

3 | 378 | 227

5 | 419 | 251

7 | 445 | 267

10 | 474 | 284

15 | 506 | 304

20 | 529 | 317

30 | 561 | 337

31 | 563 | 338

50 | 601 | 361

70 | 628 | 377

100 | 658 | 395

150 | 815 | 489

200 | 927 | 556

300 | 1085 | 651

450 | 1243 | 746

1 To calculate distance d to a public area from NEW:

NEW ≤0.5 lbs: d = 236

0.5 lbs <NEW <100 lbs: d = 291.3 + [79.2 *ln(NEW)]

100 lbs ≤NEW ≤450 lbs: d = −1133.9 + [389 *ln(NEW)]

NEW is in lbs; d is in ft; ln is natural logarithm.

To calculate maximum NEW given distance d (noting that d can never be less than 236 ft):

0 ≤d <236 ft: Not allowed (d cannot be less than 236 ft)

236 ft ≤d <658 ft: NEW = exp [(d/79.2)-3.678]

658 ft ≤d <1250 ft: NEW = exp [(d/389) + 2.914]

NEW is in lbs; d is in ft; exp[x] is e x.

2 The public traffic route distance is 60 percent of the distance to a public area.

Table E-2—Division 1.1 Distance to Public Area and Public Traffic Route for NEW >450 lbs

NEW (lbs) | Distance to public area (ft) 1 | Distance to public traffic route (ft)

450 lbs<NEW ≤30,000 lbs | 1,250 | 750.

30,000 lbs<NEW ≤100,000 lbs | 40*NEW 1/3 | 0.60*(Distance to Public Area).

100,000 lbs<NEW ≤250,000 lbs | 2.42*NEW 0.577 | 0.60*(Distance to Public Area).

250,000 lbs<NEW | 50*NEW 1/3 | 0.60*(Distance to Public Area).

1 To calculate NEW from distance d to a public area:

1, 243 ft<d ≤1,857 ft: NEW = d 3/64,000

1, 857 ft<d ≤3,150 ft: NEW = 0.2162 * d 1.7331

3,150 ft<d: NEW = d 3/125,000

NEW is in lbs; d is in ft.

Table E-3—Division 1.1 Intraline Distances 1 2 3

NEW (lbs) | Intraline Distance (ft)

50 | 66

70 | 74

100 | 84

150 | 96

200 | 105

300 | 120

500 | 143

700 | 160

1,000 | 180

1,500 | 206

2,000 | 227

3,000 | 260

5,000 | 308

7,000 | 344

10,000 | 388

15,000 | 444

20,000 | 489

30,000 | 559

50,000 | 663

70,000 | 742

100,000 | 835

150,000 | 956

200,000 | 1,053

300,000 | 1,205

500,000 3 | 1,429

700,000 | 1,598

1,000,000 | 1,800

1,500,000 | 2,060

2,000,000 | 2,268

3,000,000 | 2,596

5,000,000 | 3,078

1 To calculate intraline distance d from NEW:

d = 18*NEW 1/3

NEW is in pounds; d is in feet

2 To calculate maximum NEW from given intraline distance d:

NEW = d 3/5,832

NEW is in pounds; d is in feet.

3 NEW values of more than 500,000 lbs only apply to liquid propellants with TNT equivalents equal to those NEW values. The intraline distances for NEW greater than 500,000 pounds do not apply to division 1.1 explosives.

Table E-4—Division 1.3 Separation Distances

NEW (lbs) | Distance to public area or public traffic route (ft) 1 | Intraline distance (ft) 2

≤1000 | 75 | 50

1,500 | 82 | 56

2,000 | 89 | 61

3,000 | 101 | 68

5,000 | 117 | 80

7,000 | 130 | 88

10,000 | 145 | 98

15,000 | 164 | 112

20,000 | 180 | 122

30,000 | 204 | 138

50,000 | 240 | 163

70,000 | 268 | 181

100,000 | 300 | 204

150,000 | 346 | 234

200,000 | 385 | 260

300,000 | 454 | 303

500,000 | 569 | 372

700,000 | 668 | 428

1,000,000 | 800 | 500

1,500,000 | 936 | 577

2,000,000 | 1,008 | 630

1 To calculate distance d to a public area or traffic route from NEW:

NEW ≤1,000lbs

d= 75 ft

1,000 lbs<NEW ≤96,000 lbs

d = exp[2.47 + 0.2368*(ln(NEW)) + 0.00384*(ln(NEW)) 2]

96,000 lbs<NEW ≤1,000,000 lbs

d = exp[7.2297−0.5984*(ln(NEW)) + 0.04046*(ln(NEW)) 2]

NEW >1,000,000 lbs

d = 8*NEW 1/3

NEW is in pounds; d is in feet; exp[x] is e x; ln is natural logarithm.

To calculate NEW from distance d to a public area or traffic route (noting that d cannot be less than 75 ft):

0 ≤d <75 ft:

Not allowed (d cannot be less than 75 ft) for NEW ≤1000 lbs

75 ft ≤d≤296 ft

NEW = exp[−30.833 + (307.465 + 260.417*(ln(d)))1/2]

296 ft<d≤800 ft

NEW = exp[7.395 + (−124.002 + 24.716*(ln(d)))1/2]

800 ft<d

NEW = d 3/512

NEW is in lbs; d is in ft; exp[x] is e x; ln is natural logarithm

2 To calculate intraline distance d from NEW:

NEW ≤1,000 lbs

d = 50 ft

1,000 lbs<NEW ≤84,000 lbs

d = exp[2.0325 + 0.2488*(ln(NEW)) + 0.00313* (ln(NEW)) 2]

84,000 lbs<NEW ≤1,000,000 lbs

d= exp[4.338−0.1695*(ln(NEW)) + 0.0221*(ln(NEW)) 2]

1,000,000 lbs<NEW

d = 5*NEW 1/3

NEW is in pounds; d is in feet; exp[x] is e x; ln is natural logarithm

To calculate NEW from an intraline distance d:

0 ≤d <50 ft:

Not allowed (d cannot be less than 50 ft) for NEW ≤1000 lbs

50 ft ≤d≤192 ft

NEW = exp[−39.744 + (930.257 + 319.49*(ln(d)))1/2]

192 ft<d≤500 ft

NEW = exp[3.834 + (−181.58 + 45.249*(ln(d)))1/2]

500 ft≤d

NEW = d 3/125

NEW is in pounds; d is in feet; exp[x] is e x; ln is natural logarithm

Table E-5—Energetic Liquid Explosive Equivalents 1 2 3

Energetic liquids | TNT Equivalence | TNT Equivalence

| Static Test Stands | Launch Pads.

LO2/LH2 | See Note 3 | See Note 3.

LO2/LH2 + LO2/RP-1 | Sum of (see Note 3 for LO2/LH2) + (10% for LO2/RP1) | Sum of (see Note 3 for LO2/LH2) + (20% for LO2/RP1).

LO2/RP-1 | 10% | 20% up to 500,000 lbs Plus 10% over 500,000 lbs

IRFNA/UDMH | 10% | 10%.

N204/UDMH + N2H4 | 5% | 10%.

1 A launch site operator must use the percentage factors of table E-5 to determine TNT equivalencies of incompatible energetic liquids that are within an intraline distance of each other.

2 A launch site operator may substitute the following energetic liquids to determine TNT equivalency under this table as follows:

Alcohols or other hydrocarbon for RP-1

H2O2 for LO2 (only when H2O2 is in combination with RP-1 or equivalent hydrocarbon fuel)

MMH for N2H4, UDMH, or combinations of the two.

3 TNT equivalency for LO2/LH2 is the larger of:

(a) TNT equivalency of 8*W 2/3, where W is the weight of LO2/LH2 in lbs; or

(b) 14 percent of the LO2/LH2 weight.

Table E-6—Factors To Use When Converting Energetic Liquid Densities

Item | Density (lb/gal) | Temperature ( °F)

Ethyl alcohol | 6.6 | 68

Hydrazine | 8.4 | 68

Hydrogen peroxide (90 percent) | 11.6 | 68

Liquid hydrogen | 0.59 | −423

Liquid oxygen | 9.5 | −297

Red fuming nitric acid (IRFNA) | 12.9 | 77

RP-1 | 6.8 | 68

UDMH | 6.6 | 68

UDMH/Hydrazine | 7.5 | 68

Table E-7—Separation Distance Criteria for Storage of Hydrogen Peroxide in Concentrations of More than 91 Percent 1 2

Quantity (lbs) | Intraline distance or distance to public area or distance to public traffic route (ft)

10,000 | 510

15,000 | 592

20,000 | 651

30,000 | 746

50,000 | 884

70,000 | 989

100,000 | 1114

150,000 | 1275

200,000 | 1404

300,000 | 1607

500,000 | 1905

1 Multiple tanks containing hydrogen peroxide in concentrations of greater than 91 percent may be located at distances less than those required by table E-7; however, if the tanks are not separated from each other by 10 percent of the distance specified for the largest tank, then the launch site operator must use the total contents of all tanks to calculate each intraline distance and the distance to each public area and each public traffic route.

2 A launch site operator may use the equations below to determine permissible distance or quantity between the entries of table E-7:

W >10,000 lbs Distance = 24 * W1/3

Where Distance is in ft and W is in lbs.

To calculate weight of hydrogen peroxide from a distance d:

d >75 ft

W = exp[−134.286 + 71.998*(ln(d)) −12.363*(ln(d)) 2 + 0.7229*(ln(d)) 3]

Table E-8—Separation Distance Criteria for Storage of Liquid Hydrogen and Bulk Quantities of Hydrazine

Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids | Pounds of energetic liquid | Pounds of energetic liquid | Public area and intraline distance to incompatible energetic liquids | Intraline distance to compatible energetic liquids

Over | Not Over | Distance in feet | Distance in feet | Over | Not Over | Distance in feet | Distance in feet

| | | | 60,000 | 70,000 | 1,200 | 130

100 | 200 | 600 | 35 | 70,000 | 80,000 | 1,200 | 130

200 | 300 | 600 | 40 | 80,000 | 90,000 | 1,200 | 135

300 | 400 | 600 | 45 | 90,000 | 100,000 | 1,200 | 135

400 | 500 | 600 | 50 | 100,000 | 125,000 | 1,800 | 140

500 | 600 | 600 | 50 | 125,000 | 150,000 | 1,800 | 145

600 | 700 | 600 | 55 | 150,000 | 175,000 | 1,800 | 150

700 | 800 | 600 | 55 | 175,000 | 200,000 | 1,800 | 155

800 | 900 | 600 | 60 | 200,000 | 250,000 | 1,800 | 160

900 | 1,000 | 600 | 60 | 250,000 | 300,000 | 1,800 | 165

1,000 | 2,000 | 600 | 65 | 300,000 | 350,000 | 1,800 | 170

2,000 | 3,000 | 600 | 70 | 350,000

| 400,000 | 1,800 | 175

3,000 | 4,000 | 600 | 75 | 400,000 | 450,000 | 1,800 | 180

4,000 | 5,000 | 600 | 80 | 450,000 | 500,000 | 1,800 | 180

5,000 | 6,000 | 600 | 80 | 500,000 | 600,000 | 1,800 | 185

6,000 | 7,000 | 600 | 85 | 600,000 | 700,000 | 1,800 | 190

7,000 | 8,000 | 600 | 85 | 700,000 | 800,000 | 1,800 | 195

8,000 | 9,000 | 600 | 90 | 800,000 | 900,000 | 1,800 | 200

9,000 | 10,000 | 600 | 90 | 900,000 | 1,000,000 | 1,800 | 205

10,000 | 15,000 | 1,200 | 95 | 1,000,000 | 2,000,000 | 1,800 | 235

15,000 | 20,000 | 1,200 | 100 | 2,000,000 | 3,000,000 | 1,800 | 255

20,000 | 25,000 | 1,200 | 105 | 3,000,000 | 4,000,000 | 1,800 | 265

25,000 | 30,000 | 1,200 | 110 | 4,000,000 | 5,000,000 | 1,800 | 275

30,000 | 35,000 | 1,200 | 110 | 5,000,000 | 6,000,000 | 1,800 | 285

35,000 | 40,000 | 1,200 | 115 | 6,000,000 | 7,000,000 | 1,800 | 295

40,000 | 45,000 | 1,200 | 120 | 7,000,000 | 8,000,000 | 1,800 | 300

45,000 | 50,000 | 1,200 | 120 | 8,000,000 | 9,000,000 | 1,800 | 305

50,000 | 60,000 | 1,200 | 125 | 9,000,000 | 10,000,000 | 1,800 | 310