Radar Vectors
Regulation Current Copy saved Nov 18, 2026

§ 29.303 Factor of safety

Official source ↗

Unless otherwise provided, a factor of safety of 1.5 must be used. This factor applies to external and inertia loads unless its application to the resulting internal stresses is more conservative.