§ 25.1391 Minimum intensities in the horizontal plane of forward and rear position lights
Text changed: 1 of 1 passage.
- Date
- Nov 18, 2026
- Recorded
- Nov 18, 2026
- Passages
- 1 of 1 changed
- Paragraphs
- 1 added or rewritten, 1 removed or rewritten
Read the current text Official source ↗
What changed in the text
Key: [removed: removed words] are struck through; [added: added words] are underlined. Each changed paragraph is labelled in the margin.
Each position light intensity must equal or exceed the applicable values in the following table:
Dihedral angle (light included) | Angle from right or left of longitudinal axis, measured from dead ahead | Intensity (candles)
- Changed
L and R (forward red and green) | 0° to
[removed: 10°10°][added: 10° 10°] to[removed: 20°20°][added: 20° 20°] to 110° |[removed: 40305][added: 40 30 5] A (rear white) | 110° to 180° | 20
Whole text before this change
Each position light intensity must equal or exceed the applicable values in the following table:
Dihedral angle (light included) | Angle from right or left of longitudinal axis, measured from dead ahead | Intensity (candles)
L and R (forward red and green) | 0° to 10°10° to 20°20° to 110° | 40305
A (rear white) | 110° to 180° | 20
Whole text after this change
Each position light intensity must equal or exceed the applicable values in the following table:
Dihedral angle (light included) | Angle from right or left of longitudinal axis, measured from dead ahead | Intensity (candles)
L and R (forward red and green) | 0° to 10° 10° to 20° 20° to 110° | 40 30 5