Radar Vectors
Airworthiness Directive Current Issued Feb 2, 1981 Copy saved Nov 18, 2026

AD 80-08-06R1 GENERAL ELECTRIC COMPANY Model CJ610-8A and -9, CF700-2D and -2D-2 Engines

Turbine Disks

Official source ↗

Regulatory Text

80-08-06 R1 GENERAL ELECTRIC COMPANY: Amendment 39-3740 as amended by Amendment 39- 4005. Applies to CJ610-8A and -9 turbojet and CF700-2D and -2D-2 turbofan engines with turbine disks identified by serial numbers below.

To prevent low cycle fatigue failure of turbine disks suspected to have foreign material segregation, accomplish the following within the next 50 cycles.

Remove from service first stage turbine disks, P/N 5011T75P01, and second stage turbine disks P/N 5011T76P01, with serial numbers listed below and replace with serviceable disks:

SERIAL NUMBERS:

FIRST STAGE: GATWZA 00585 GATWZA 00637 GATWZA 00677

GATWZA 00587 GATWZA 00640 GATWZA 00679

GATWZA 00599 GATWZA 00641 GATWZA 00680

GATWZA 00601 GATWZA 00642 GATWZA 00681

GATWZA 00604 GATWZA 00644 GATWZA 00682

GATWZA 00607 GATWZA 00645 GATWZA 00683

GATWZA 00610 GATWZA 00646 GATWZA 00687

GATWZA 00611 GATWZA 00647 GATWZA 00690

GATWZA 00613 GATWZA 00649 GATWZA 00691

GATWZA 00615 GATWZA 00652 GATWZA 00692

GATWZA 00616 GATWZA 00658 GATWZA 00693

GATWZA 00617 GATWZA 00662 GATWZA 00704

GATWZA 00618 GATWZA 00663 GATWZA 00705

GATWZA 00624 GATWZA 00664 GATWZA 00706

GATWZA 00626 GATWZA 00665 GATWZA 00707

GATWZA 00627 GATWZA 00667 GATWZA 00708

GATWZA 00630 GATWZA 00671 GATWZA 00709

GATWZA 00632 GATWZA 00672 GATWZA 00710

GATWZA 00633 GATWZA 00673 GATWZA 00713

GATWZA 00634 GATWZA 00674 GATWZA 00714

GATWZA 00635 GATWZA 00676 GATWZA 00715

FIRST STAGE: OJAWZA 11J774-22

OJAWZA 11J796-20

OJAWZA 11J796-01

OJAWZA 11J796-21

OJAWZA 11J796-03

OJAWZA 11J796-23

OJAWZA 11J796-04

OJAWZA 11J796-24

OJAWZA 11J796-05

OJAWZA 11J796-31

OJAWZA 11J796-06

OJAWZA 11J796-32

OJAWZA 11J796-07

OJAWZA 11J796-35

OJAWZA 11J796-08

OJAWZA 11J796-41

OJAWZA 11J796-09

OJAWZA 11J796-42

OJAWZA 11J796-11

OJAWZA 11J796-43

OJAWZA 11J796-13

OJAWZA 11J796-44

OJAWZA 11J796-15

OJAWZA 11J796-45

OJAWZA 11J796-16

SECOND STAGE: GATWZA 00541 GATWZA 00583 GATWZA 00614

GATWZA 00542 GATWZA 00585 GATWZA 00616

GATWZA 00545 GATWZA 00587 GATWZA 00617

GATWZA 00547 GATWZA 00588 GATWZA 00618

GATWZA 00548 GATWZA 00589 GATWZA 00619

GATWZA 00549 GATWZA 00590 GATWZA 00621

GATWZA 00550 GATWZA 00592 GATWZA 00622

GATWZA 00551 GATWZA 00593 GATWZA 00623

GATWZA 00552 GATWZA 00594 GATWZA 00624

GATWZA 00553 GATWZA 00595 GATWZA 00630

GATWZA 00554 GATWZA 00596 GATWZA 00632

GATWZA 00557 GATWZA 00597 GATWZA 00634

GATWZA 00563 GATWZA 00598 GATWZA 00636

GATWZA 00564 GATWZA 00600 GATWZA 00637

GATWZA 00565 GATWZA 00601 GATWZA 00638

GATWZA 00566 GATWZA 00602 GATWZA 00640

GATWZA 00567 GATWZA 00604 GATWZA 00642

GATWZA 00570 GATWZA 00605 GATWZA 00643

GATWZA 00571 GATWZA 00607 GATWZA 00646

GATWZA 00574 GATWZA 00609 GATWZA 00648

GATWZA00575 GATWZA 00610 GATWZA 00649

GATWZA 00577 GATWZA 00611 GATWZA 00651

GATWZA 00580 GATWZA 00612

GATWZA 00581 GATWZA 00613

SECOND STAGE: OJAWZA 11J781-01

OJAWZA 11J781-19

OJAWZA 11J781-02

OJAWZA 11J781-20

OJAWZA 11J781-03

OJAWZA 11J781-21

OJAWZA 11J781-04

OJAWZA 11J781-22

OJAWZA 11J781-05

OJAWZA 11J781-23

OJAWZA 11J781-06

OJAWZA 11J781-24

OJAWZA 11J781-07

OJAWZA 11J781-25

OJAWZA 11J781-08

OJAWZA 11J781-26

OJAWZA 11J781-09

OJAWZA 11J781-27

OJAWZA 11J781-10

OJAWZA 11J781-28

OJAWZA 11J781-11

OJAWZA 11J781-29

OJAWZA 11J781-12

OJAWZA 11J781-31

OJAWZA 11J781-13

OJAWZA 11J781-32

OJAWZA 11J781-14

OJAWZA 11J781-33

OJAWZA 11J781-15

OJAWZA 11J781-34

OJAWZA 11J781-16

OJAWZA 11J781-35

OJAWZA 11J781-17

OJAWZA 11J781-37

OJAWZA 11J781-18

OJAWZA 11J781-38

General Electric Company Alert Service Bulletin Nos. (CJ610) A72-135, Addendum 1, dated May 19, 1980, and (CF700) A72-142, Addendum 1, dated May 19, 1980, refer to this subject.

This amendment was effective upon receipt of the Emergency Airworthiness Directive dated May 30, 1980, and is effective to all others on February 2, 1981.