AD 47-21-08 Navion Serial Numbers NAV-4-2 Through 411

Generator Terminal Stud Insulator

Official source ↗

Regulatory Text

47-21-08 NAVION: (Was Mandatory Note 7 of AD-782-3.) Applies to Serial Numbers NAV-4-2 Through 411.

To be accomplished not later than August 1, 1947.

Short circuits have been reported caused between the generator lower terminal and the fitting on the hydraulic pump inlet hose. To prevent such short circuits, install a self-threading insulator No. 145-54053 (or equivalent) on the generator lower terminal stud.