Radar Vectors
Advisory Circular Cancelled Issued Oct 20, 1997 AAS-100 92 pages Copy saved Nov 18, 2026

AC 150/5220-10B Guide Specification for Water/Foam Aircraft Rescue and Firefighting Vehicles

Contains performance standards, specification, and recommendations for the design, construction, and testing of water/foam aircraft rescue and firefighting (ARFF) vehicles.

This document is cancelled. It may have been replaced. Check the official source before relying on it.

Official source ↗ Open PDF

Advisory u.s. Department of Transportation Circular Federal Aviation Administration

Subject: GUIDE SPECIFICA nON FOR W A TERIFOAM AIRCRAFT RESCUE AND FIREFIGHTING VEHICLES

1. PURPOSE. This advisory circular (AC) contains perfonnance standards, specifications, and recommendations for the design, construction, and testing of a family of aircraft rescue and firefighting (ARFF) vehicles.

2. CANCELLATION. AC l50/5220-IOA, Guide Specification for Water/ Foam Aircraft Rescue and Firefighting Vehicles, dated July 3, 1991, is canceled.

3. APPLICATION. The Federal Aviation Administration recommends the use of the guidance in

DAVID L. BENNETT Director, Office of Airport Safety and Standards

CANCELLED

Date: 10/20/97 AC No: l50/5220-IOB Initiated by: AAS-100 Change:

this publication for the preparation of ARFF vehicle specifications. For airport projects receiving Federal grant-in-aid assistance, the use of these standards is mandatory. At certificated airports, the use of equipment meeting these standards is an acceptable means of satisfying the requirements of Federal Aviation Regulations (FAR), Part 139, Subpart D­ Operations, Subparagraph 13 9.317, Aircraft rescue and firefighting: Equipment and agents.

CANCELLED

1

10/20/97 AC 150/5220-10B

CONTENTS

CHAPTER 1. INTRODUCTION …

Section 1. General Characteristics … 1

1. DEFINITIONS … 1 2. EXPECTED USE … 1 3. FIRE SUPPRESSION CHARACTERISTICS … 1 4. RESERVED … 1

Section 2. Ergonomics … 1

5. CREW SPACE … 1 • 6. RIDE QUALITY … 2 7. CONTROLS … 2 8. SAFETY FEATURES … 2

Section 3. Design Criteria … 2

9. PERFORMANCE … 2 10. FLEXIBILITY … 3 11. MAINTAINABILITY … 3 12. COMPONENT PROTECTION … 3 13. PAINTING, MARKING, AND LIGHTING … 4 14. INSULATION, WATERPROOFING, AIR CONDITIONING, AND WINTERIZATION. … 4 15. MATERIALS … 4 16. THROUGH 19. RESERVED … 4

CHAPTER 2. AUTOMOTIVE SYSTEM … 5

Section 1. Frame … 5

20. BALANCE AND CLEARANCES … 5 21. DIMENSIONS … 5 22. LOAD RATING … 5

Section 2. Body Components … 5

23. COACH WORK … 5 24. COMPARTMENTS … 5 .. 25. HANDRAILS … 6 26. RUNNING BOARDS, STEPS, WALKWAYS, AND TOWING DEVICES . … 6

Section 3. Cab and Accessories … 6

27. CONTROLS … 6 28. CREW SPACE AND DOORS … 7 29. EQUIPMENT … 8 30. INSTRUMENTS AND WARNING LIGHTS … 8

Section 4. Driveline and Controls … 8

31. AXLES … 8 32. BRAKE SYSTEM … 8 33. STEERING … 9 34. SUSPENSION … 10 35. TRANSFER CASE … 10

CANCELLED

iii

AC 150/5220-10B 10/20/97

36. TRANSMISSION … 10 37. WHEELS AND TIRE ASSEMBLY … 10

Section 5. Electrical System … 1 1

38. COOLANT HEATER … 1 1 39. LIGHTING AND MARKING SYSTEM … 1 1 40. POWER SUPPLIES … 1 1 41. STARTER … 12 42. WIRING … 12 43. RADIO INTERFERENCE … 12

Section 6. Engine and Accessories … 13

44. COOLING SYSTEM … 13 45. EXHAUST SYSTEM … 1 3 46. FUEL SYSTEM … 13 47. GOVERNOR … 1 3 48. LUBRICATION … 1 4 49. POWER REQUIREMENT … 14 50. WINTERIZATION -- OPTION … 14

Section 7. Automotive Performance … 14

51. ACCELERATION … 14 52. BRAKE SYSTEM … 14 53. DYNAMIC AND STATIC STABILITY . … 14 54. ENVIRONMENTAL CONDITIONS … 15 55. GRADABILITY … 15 56. OPERATIONAL RANGE … 15 57. TOP SPEED … 15 58. OFF-ROAD HIGH MOBILITY SUSPENSIONS … 1 5 59. DRIVER'S ENHANCED VISION SYSTEM (DEVS) … 1 6 60. THROUGH 69. RESERVED … 1 6

CHAPTER 3. FIRE EXTINGUISHING SYSTEMS … 1 9

Section 1. Dry Chemical -- Option … 1 9

70. AGENT CONTAINER(S) AND COMPONENTS … 1 9 71. AGENT DELIVERY PIPING AND VALVES … 19 72. PROPELLANT, PROPELLANT CONTAINERS AND COMPONENTS … 19

Section 2. Halotron I or an Acceptable Substitute -- Option … 20

73. AGENT CONTAINER AND COMPONENTS … 20 74. AGENT DELIVERY PIPING AND VALVES … 20 75. PROPELLANT, PROPELLANT CONTAINERS, AND COMPONENTS. … 20

Section 3. Foam Concentrate System … 2 1

76. CONCENTRATE PROPORTIONER … 21 77. CONCENTRATE RESERVOIR AND PIPING … 21

Section 4. Water System … 22

78. PIPING, COUPLINGS, CONNECTIONS, AND VALVES . … 22 79. WATER PUMPS AND PUMP DRIVE … 22 80. WATER RESERVOIR AND PIPING … 23

CANCELLED

iv

10/20/97 AC 150/5220-10B

Section 5. Handlines, Reels, and Compartments … 24

81. HAND LINES . … 24 82. WOVEN JACKET HOSE AND REEL HOSE COMPARTMENTS … 24

Section 6. Ground Sweep, Turrets, and Undertruck Nozzles … 25

83. GROUND SWEEP OR BUMPER TURRET … 25 84. PRIMARY TURRET … 25 85. HIGH-REACH, EXTENDABLE TURRET-OPTION … 25 86. UNDERTRUCK NOZZLES -- OPTION … 27 87. DUAL AGENT TURRET--OPTION … 27

• Section 7. Agent System Performance … 27

88. COMPLEMENTARY AGENT SYSTEM -- OPTION … 27 89. WATERIFOAM AGENT APPLICATORS … 27 90. THROUGH 99. RESERVED … 27

CHAPTER 4. QUALITY ASSURANCE … 3 1

Section 1. General Consideration … 3 1

100. CRITERIA FOR VEHICLE ACCEPTANCE . … 31 101. TECHNICAL SERVICE , PERFORMANCE DOCUMENTATION , AND TRAINING … 3 1 102. NAMEPLATES AND INSTRUCTION PLATES … 32

Section 2. Certification of Performance … 32

103. COMPONENT MANUFACTURER'S CERTIFICATION . … 32 104. VEHICLE MANUFACTURER'S CERTIFICATION … 33

Section 3. Prototype Vehicle Performance 33 … 105. PROTOTYPE TEST LIST … 33 106. BRAKE SYSTEMS PERFORMANCE … 34 107. COMPLEMENTARY AGENT SYSTEM … 36 108. ELECTRICAL CHARGING SYSTEM . 38 … 109. BODY AND CHASSIS FLEXIBILITY . … 40 110. FOAMIWATER AGENT SYSTEM … 41 Ill. GRADABILITY … 49 112. RADIO INTERFERENCE SUPPRESSION . … 50

114.

.. 113. SIREN SOUND OUTPUT: DIRECTION AND MAGNITUDE … 51 STABILITY: DYNAMIC AND STATIC . 51 … 115. STEERING SYSTEM: RESISTANCE AND TURNING DIAMETER … 52 116. UNDERBODY CLEARANCES . … 53 117. VISIBILITY: INCLUDED ANGLES FROM DRIVER'S SEAT … 54 118. VEHICLE INTERIOR NOISE LEVEL … 55 119. THROUGH 120. RESERVED … 56

Section 4. Production Vehicle Performance Acceptance Tests … 56

121. PRODUCTION TEST LIST … 56 122. ACCELERATION … 56 123. AIR COMPRESSOR CAPACITY . 57 …

… 124. BALANCEIWEIGHT DISTRIBUTION . 58 125. BRAKING CONTROL . 59 … 126. FOAMIWATER PROPORTIONER(S) TOLERANCE . 59 … 127. FOAMIWATER SOLUTION PUMP DISCHARGE STABILITY . … 60

v

CANCELLED

AC 150/5220-10B 10/20/97

128. DUAL PUMP DISCHARGE STABILITY . … 61 129. PRESSURE TEST OF PIPING AND CONNECTIONS . … 61 130. PUMP AND ROLL CAPABILITY … 62 131. ROOF TURRET DISCHARGE RATE … 62 132. TOP SPEED … 63

APPENDIX 1. DEFINITIONS … 1

APPENDIX 2. OFF-PAVEMENT MOBILITY … 1

APPENDIX 3. EQUIPMENT FOR AIRCRAFT RESCUE AND … 1

APPENDIX 4. PURCHASER ELECTION OF SUBSYSTEM COMPONENTS … 1

TABLES

1. Minimum Usable Water (Rated Capacity) … 1 2. Automotive Performance Standards … 17 2M. Automotive Performance Standards (Metric) … 1 8 3. Extinguishing Agent System Performance Standards … 28 3M. Extinguishing Agent System Performance Standards (Metric ) … 29 4. Foam Quality Standards … 30

Appendix 3 A3-1. Recommended Equipment For Response Operations … 2

Appendix 4 A4-1. Work Sheet For Subsystem Component Selection … : … 2

FIGURES

Appendix 2 A2-1. Accident Site Locations And The Critical ARFF Access Area … 4 A2-2. Areas For Potential Off-Pavement ARFF Operations … 4

CANCELLED

vi

-

10/20/97 AC 1 50/5220-10B

CHAPTER 1. INTRODUCTION.

Section 1. General Characteristics.

1. DEFINITIONS. Terms with meanings unique or specifically related to aircraft rescue and firefighting (ARFF) vehicle design, construction, and performance requirements are contained in Appendix 1 .

2 . EXPECTED USE. This guide specification covers four classes of all-wheel drive, diesel-powered

• ARFF vehicles having a mechanical foam/water system designed for extinguishing flammable and combustible

liquid fuel fires. The dry chemical and Halotron I or approved equivalent complimentary agent systems described in chapter 3 are acceptable, optional

additions to the basic vehicle when dictated by local operational needs. However, the primary function of the vehicles described in this guide specification is to

provide an optimum level of ARFF suppression capability throughout the critical rescue and frrefighting access area for the lowest practical cost.

CANCELLED

These vehicles may also be suitable for other fire protection assignments at the airport. Vehicles complying with this basic specification meet the ARFF vehicle requirements of 14 Code of Federal Regulations (CFR) Part 1 39.

3. FIRE SUPPRESSION CHARACTERISTICS. These vehicles are designed for a degree of offpavement mobility not normally found in highway vehicles. The vehicle payload consists principally of the minimum usable (rated capacity) quantities of

water shown in Table 1 and sufficient foam concentrate to mix at the appropriate concentration with twice that

water quantity.

4. RESERVED.

Table 1. Minimum Usable Water (Rated Capacity) .

Class Gallons (US) Lih'rs

1 1,000 3785

2 1,500 5678

3 2,500 9463

4 3,000 and over 11 355 and over

Section 2. Ergonomics.

5. CREW SPACE.

a. All crew space shall be restricted to the interior of a fully enclosed cab. The maximum crew capacity of the cab (seated positions with approved, 3-point restraints as minimum seat belts or shoulder harness system) shall be clearly posted on a label in the cab.

b. Where practicable, instruments shall be used in preference to warning lights. A means to readily test the condition of all warning light bulbs shall be provided.

C. Instruments and warning lights shall be displayed so that they will be useful, convenient, and visible to the driver.

d. The instrument panel(s) shall either be easily removable as units or hinged for back access. Quick disconnect fittings shall be used for all electrical

connections to the instrument panel. All instruments, except liquid filled gauges, shall be illuminated by red lighting. Labels for control and instruments should be backlit or illuminated.

e. Provisions shall be made to mount the radio(s) and the associated controls such that they shall be

AC 150/5220-IOB 10/20/97

operable by the driver and at least one other crew member without leaving the cab or removing their seat belts. The mounting provisions shall take into consideration the fact that radio operating equipment may include boom/microphone headsets with appropriate controls, radio interconnects, and remote or foot-operated push-to-talk switches, as specified by the purchaser. If a vehicle is to be equipped with headsets, appropriate storage boxes shall be provided to protect this equipment.

f. All rotating or ,reciprocating parts, all parts with operating temperatures above 1200 F (490 C), or which are electrically energized, or are of such a nature or so located as to be a hazard to the safety of operating and maintenance personnel during their normal duties, shall be insulated, enclosed, or guarded as appropriate for the specific hazard and its location.

g. All space which is occupied or from which work is performed during operations, servicing, and maintenance of the vehicles, shall be free from hazardous protrusions, sharp edges, cracks, or other

elements which might reasonably be expected to cause injury to personnel.

6. RIDE QUALITY .

a. The design objective for the vehicle ride quality shall be to permit safe operation over rough roads and adverse terrain found at the airport of intended service at speeds up to at least 15 mph (24 km/h) without causing injury to the operating personnel (wearing seat belts) or damage to the vehicle.

b. The design objective for all vehicle and fire extinguishing system controls shall be to permit driving and firefighting operations which do not require effort by operating personnel in excess of the

limits specified in the current version of MIL-STD­

1472, Human Engineering Design Criteria for Military Systems, Equipment and Facilities.

CANCELLED

7. CONTROLS.

a. All the controls necessary for the full operation of the vehicle and for activating the frrefighting system shall be within reach of the driver. Controls for the fire extinguishing system(s) shall also be within easy reach of a second crew station or duplicated for that crew station.

b. Firefighting equipment and controls located on the vehicle exterior shall be placed between 24 inches (61 cm) and 66 inches (168 cm) above the ground, catwalks, or deck plates, as applicable.

c. All controls shall be labeled with a permanent label identifying function and/or limitation.

8. SAFETY FEATURES.

a. A warning siren/device shall be provided, and it shall:.

(1) be a multi-tone, multi-volume state-ofthe-art device used as a common industry practice on

emergency vehicles.

(2) produce a minimum sound of 95 decibels at 100 feet (30 m) directly in front of the vehicle; and 90 decibels at 100 feet (30 m) and 45 degrees left and right of front center.

(3) be mounted so as to be protected from drippings from the turret and water splashed up by the tires. The control(s) shall be accessible to both the driver and a second crew member.

b. A hom shall be provided and mounted so as to achieve optimum sound projection to the front of the vehicle. A control button or hom ring shall be located at the steering wheel.

c. A "vehicle backing" warning device, audible up to 25 feet (7.6 m) behind the vehicle, shall be provided. Shifting the transmission into reverse shall activate this device.

Section 3. Design Criteria.

9. PERFORMANCE. The design objective for the Performance for the fire extinguishing system shall be vehicle and the fire extinguishing system shall be in accordance with Section 7, Chapter 3. performance in accordance with Section 7, Chapter 2. Manufacturers shall be required to identify their loaded

10/20/97 AC 150/5220-10B

apparatus' center of gravity as well as the safe operating envelop of the loaded vehicle to include side

slope maneuverability and high speed cornering.

10. FLEXIBILITY. The design objective for the vehicle frame, suspension, and mounting of major components shall be to provide the capability for diagonally opposite wheel motion up to 14 inches (36 cm) above ground without raising the remaining wheels from the ground or causing interference or parts failure.

11. MAINTAINABILITY. The vehicle design shall be such that it:

a. Uses the fewest number of different parts consistent with the specified performance.

h. Permits maintenance with commercially available, general purpose mechanic· tools and equipment (metric sizes are permitted if required tools are "standard" and "commercially available"). The vehicle manufacturer shall identify and document in the maintenance manual introduction any special or nonstandard tools required and any unique test

equipment required to perform operator/owner maintenance and service.

c. Limits the number of tools and the variety of spare parts required for maintenance by such design practices as reducing the variety of bolt sizes, light bulb sizes, wire gages, tubing and pipe sizes consistent with safety and performance requirements.

d. Uses disconnect plugs, receptacles, junction boxes, bus bars, multiple-line connectors in the electrical systems, and readily detachable fittings in hydraulic and pneumatic systems, as applicable. All disconnect points shall be clearly labeled. All hydraulic and pneumatic lines and electrical wires shall be color- or number-coded.

e. Includes pilots, guides, slides, carriages, or other features where such provisions can add to the ease of removal and installation or attachment of components.

f. Uses a fastener system that is easily dissembled and reassembled for all cabinets and bodywork that must be removed for access for maintenance

and removal of components for repair or replacement.

CANCELLED

g. Operates with standard commercial lubricants. Grease and oil seals shall be of a design and located to provide accessibility for inspection, servicing, and replacement. Panels which must be opened for access to lubrication points shall be hinged. Lubrication fittings shall be located in accessible, protected positions. Parts or assemblies which are not readily accessible for direct lubrication, or are likely to be overlooked because of inaccessibility, shall have extended fittings. A safety chain shall attach filler caps to lubrication fill points where practical.

h. Locates drains, filler plugs, grease fittings, hydraulic line-bleeders, and checkpoints so that they are readily accessible and do not require special tools for proper servicing.

i. Ensures that the installation of each major subsystem or critical part can only be in its proper operating position.

j. Provides accessible connections, where needed, to attach troubleshooting, analytical, and diagnostic equipment to appropriate vehicle subsystems.

k. Includes the installation of continuous duty cycle lubrication systems for suspension lubrication points and other mechanical equipment joints to increase the duty cycle of components and extend the useful life of the vehicle.

12. COMPONENT PROTECTION.

a. All oil, hydraulic, air, water, foam concentrate, and electrical system conduits, tubing and hoses shall be located in protected positions. They shall be secured to the frame or body structure and, except where a through-frame connector is necessary, shall be fitted with protective looms or grommets at each point where they pass through panels or structural members.

h. All radiator grills, louvers, lamps, tie rods, drive shafts, piping, and other vulnerable components shall be protected by component location or by guards adequate to prevent damage from brush, stones, logs, etc., likely to be encountered by the vehicle during offroad performance.

AC 150/5220-IOB

13. PAINTING, MARKING, AND LIGHTING.

a. Vehicles shall be painted and marked to comply with the painting, marking and lighting standards of AC 150/52 1O-5B, Painting, Marking, and Lighting of Vehicles Used on an Airport.

b. Lighting equipment shall be provided as specified in paragraph 39.

14. INSULATION, WATERPROOFING, AIR CONDITIONING, AND WINTERIZATION.

a. Insulation shall be fire and water resistant and of a type that will not pack or settle. Provision shall be made to allow the drainage of water from between the walls by gravity flow. The average heat loss shall not exceed 0.24 BTUlft;2 (0.76 W/m2) per degree Fahrenheit per hour. All insulation which could be exposed to abrasion or damage from equipment storage or operator activities shall be provided with a protective covering. All insulation which will be located on the exterior of the vehicle shall be protected from damage of exposure by a permanent cover to be constructed and painted to match the vehicle exterior (metal or fiber glass).

b. All components shall be designed, installed and/or protected so that their normal function will not be impaired by heavy rains, road splash, formation of condensation, or the spillage of extinguishing agents from nozzles and fittings, recharging operations, or leaks in the piping system.

C. The normal temperature design criteria shall be for vehicle use in a temperature range of 32° F (0° C) to 1 15° F (43.5° C).

d. If, in the judgment of the purchaser, the operational practices of the ARFF service at a specific airport warrant the use of air conditioning, a system that meets current automotive/truck and environmental protection standards for vehicle air conditioning may be specified by the purchaser. The use of the air conditioning shall not change the acceptable pass/fail criteria for any of the performance tests of the vehicle or the firefighting system by more than ± 5 percent

CANCELLED

when tested in ambient temperatures up to 1 15° F

(43S C).

e. If, in the judgment of the purchaser, the climatic conditions combined with the normal operational procedures at a specific airport warrant the use of special freeze protection, a winterization system that meets the requirements of paragraph 50 may be specified by the purchaser.

15. MATERIALS.

a. Materials not specifically covered by this specification or applicable referenced specifications or standards shall be of the best quality currently used in commercial practice for ARFF vehicle fabrication.

b. Dissimilar metals shall not be in contact with each other. Metal plating or metal spraying of dissimilar base metals to provide electromotively compatible abutting surfaces is acceptable. The use of dissimilar metals separated by suitable insulating material is permitted, except in systems where bridging of insulation materials by an electrically conductive fluid can occur.

C. Materials that deteriorate when exposed to sunlight, weather, or operational conditions normally encountered during service shall not be used or shall have a means of protection against such deterioration that will not prevent compliance with performance

requirements.

d. Protective coatings that chip, crack, or scale with age or extremes of climatic conditions or on exposure to heat shall not be used.

e. The use of proven, nonmetallic materials in lieu of metal is permitted if that use contributes to reduced weight, lower cost, or less maintenance and there is no degradation in performance or increase in long-term operations and maintenance costs.

16. THROUGH 19. RESERVED.

10/20/97 AC 150/5220-IOB

CHAPTER 2. AUTOMOTIVE SYSTEM.

Section 1.

20. BALANCE AND CLEARANCES.

a. The weight shall be distributed as equally as practical over the axles and tires of the fully laden vehicle.

(1) The difference in tire load between tires on any axle shall not exceed 5 percent of the average tire load for that axle.

(2) The difference in load between axles shall not exceed 10 percent of the load on the heaviest axle.

(3) The front axle shall not be the heaviest axle.

EXCEPTION: The front axle may be the heaviest loaded axle in those cases where options specified by the purchaser cannot be practically engineered to conform with this requirement. However, if the front axle is the heaviest, the weight difference between it and any other axle shall not exceed 5 percent. In addition, none of the component ratings shall be

exceeded to accommodate this deviation in the balance/weight distribution AND all other performance requirements of this specification shall be met.

(4) Under no circumstances shall axle and tire manufacturer's ratings be exceeded in an effort to

comply with any of the above.

b. The fully loaded vehicle shall be able to meet the side slope stability standards of Table 2, Performance Parameter 2, applicable to its class.

CANCELLED

Frame.

c. See Table 2, Performance Parameters 4 through 8, for standard clearances.

21. DIMENSIONS.

a. The overall height, length, and width of the vehicle shall be the smallest dimensions consistent with the rated payload for its class and the operational performance requirements of the vehicle.

b. Although payload and operational performance are of primary importance, costeffectiveness and local functional consideration, e.g., existing door, bridge, and tunnel clearances, may dictate that one or more specific dimensional requirements be specified by the purchaser.

22. LOAD RATING.

a. The functional load rating of the frame shall equal or exceed the actual gross vehicle weight (GVW). The GVW includes complete chassis; cab with attachments, accessories, and equipment; the body with rated agent payload, including a full complement of fuel, lubricant, coolant, firefighter protective clothing, equipment, and breathing apparatus in appropriate numbers; firefighting hand tools and appliances.

b. The frame shall not be altered during installation of the fire protection package in any way which will reduce its load rating.

Section 2. Body Components.

23. COACH WORK. Parts shall be fabricated from materials that will provide the lightest weight consistent with the needs for strength, as well as heat and corrosion resistance. Self-tapping bolts shall not be used in construction of the apparatus body. Safety of the crew shall be a primary consideration in coach work, especially the protection of occupants during a roll over.

24. COMPARTMENTS. The compartments shall be of weather-tight construction and equipped with

closures. Closures shall have positive holding mechanisms in both open and closed positions and maybe oftracklroll or hinge/swing type. All compartments shall:

a. Be provided with weather proof lights which are switched to automatically light when compartment doors are opened.

AC 150/5220-lOB 10/20/97

b. Have minimum of two (2) vents with a total of 10 squares inches of ventilation. The ventilation shall not be to the outside of the vehicle.

c. Have a drain to allow collected water to run out under the vehicle.

d. Be equipped with a sensor, switch, or device that would send a signal to an indicator in the cab that

a compartment door is open.

25. HANDRAILS. Handrails or a guardrail shall be provided for personnel safety at all steps, walkways, and elevated work stations: including along the vehicle tank top or tank top fill area. The rail material shall be heat and corrosion-resistant or provided with a low maintenance, durable, sunlight, weather, heat, and

corrosion-resistant finish. Handrails finish should be of a design that is slip resistant.

26. RUNNING BOARDS, STEPS, WALKWAYS, AND TOWING DEVICES.

a. Running boards, step surfaces, ladder rungs, walkways, and catwalks shall have antiskid treads, deck plates, handrails, and guards as applicable.

(1) The height between steps shall be less than 20 inches (50 cm).

CANCELLED

(2) The lower steps shall be less than 24 inches (60 cm) from the ground. The lowermost steps may extend below the angle of approach or departure or ground clearance limits if they are designed to swing clear.

(3) The tread of the bottom steps shall be at least 8 inches (20 cm) in width and succeeding steps at least 16 inches (40 cm) in width.

(4) The full width of all steps shall have at least 6 inches (15 cm) of unobstructed toe room or depth when measured from and perpendicular to the front edge of the weight-bearing surface of the step.

b. Catwalks and deck plates which provide access to equipment mounted on the vehicle shall withstand the loads imposed by personnel while performing normal service and operational functions.

c. Two towing hooks/eyes with shackles shall be attached directly to the frame rails at the front and rear of the vehicle. If requested by the purchaser as an alternate to the rear towing hooks, a pintle hook may be attached to the rear frame cross member of the vehicle if its presence will not interfere with other components necessary for the required performance. The towing devices may be allowed to intrude into the 30 degree approach angle in order to provide ease of connection if needed.

Section 3. Cab and Accessories.

27. CONTROLS. Unless otherwise noted, the following cab mounted controls shall be provided as applicable for the safe and efficient operation of the vehicle:

Accelerator Pedal. Agent Flow Control. Air Conditioner Controls, if specified. Brake Pedal. Complimentary Agent/System Activatioll Differential Lock Control. Dimmer Control. Dome Light Switch ManuallDoor Activated, with

white/red light selector switch if specified. Engine Shutdown Switch. Flashing Beacon Switch(es). Foam Concentrate Reservoir Control Valve. Headlight Switch.

HeaterlDefroster Controls. Hom Control. Ignition Switch. Master Electrical Disconnect Switch. Panel Lights Switch with Dimmer. Parking Brake Control. Siren Switch with Microphone. Spotlight SWitch(es), if spcified. Starter Switch. Steering Wheel, with Self-Canceling

Direction Signal Top Deck Light Switches, if specified. Transmission Range Selector. Turret Control. Water Flow Control Valve. Windshield Deluge System Control, if requested. Windshield Wiper and Washer Controls.

10/20/97 AC 150/5220-1OB

28. CREW SPACE AND DOORS.

a. The cab shall:

(1) Have seats for a driver and at least one additional crew member.

NOTE: If additional crew positions are a local operational requirement and are specified by the purchaser, they shall be provided.

(2) Have space for the instruments, radios, controls, and the safety equipment required by the number of firefighters intended to occupy the cab, without hindering crew operations.

(3) Have door(s) which open to at least a 90 degree angle to the cab side on each side of the cab and that shall be fitted with appropriate steps and hand grabs. The location of vehicle components or mounted firefighting equipment shall not obstruct the cab entrances/exists.

(4) Be constructed and/or so mounted on the vehicle frame so to meet the provisions of paragraph 10.

(5) Be constructed to prevent cab collapse in the event of a vehicle rollover.

(6) Be weather tight and fully insulated in accordance with the provisions of paragraph 14.

b. The cab roof shall have gutters of sufficient size to prevent foam and water from dripping on the windshield and side windows during turret operation. All cab fresh air vents/intakes shall be baffled and drained in such a way that wind-driven rain water and/or water-foam solution sprayed on the vehicle cannot flow into the crew compartment through the air intakes.

c. All glass shall be a laminated or tempered, tinted safety type to meet applicable Federal standards and shall be free of imperfections which affect visibility.

d. The design and arrangement of the cab and components shall optimize visibility for a seated driver having an eye height of 3 1 3/4 inches (80 cm).

CANCELLED

(2) The ground must be visible to the driver at a point at least 15 feet (4.5 m) and beyond from the vehicle through the left two-thirds of the included angle of vision and 30 feet (9 m) from the vehicle through the right third of the included angle.

EXCEPTION: Proportional modification of the horizontal visibility range is acceptable for other than a left-mounted driver seat.

(3) The angle of visibility above the horizontal for the seated driver looking through the front cab windows shall be at least 5 degrees. For vehicles equipped with high-reach, extendible turrets, the angle of visibility above the horizon shall extent to a point 30 feet (9m) above ground level at a distance of

1 5 feet (4.5m) in front of the vehicle.

(4) Restriction of the horizontal angle of vision by window frames, comer and door posts, etc., shall not exceed 7 degrees per obstruction.

(5) Forward vision for the driver, looking through the windshield between the forward comer posts of the cab, shall be unobstructed.

EXCEPTION: A center post Is acceptable if the width is under 2 inches (50 mm), and there are no blind areas at a distance of 40 feet (12 m) from the vehicle when viewed by the driver using both eyes

and sitting in a normal operating position.

e. Cab interior noise level at the driver's ear position (eye height in paragraph (d) above) shall not exceed 85 dB(A) when measured in accordance with 49 Code of Federal Regulations (Transportation), Chapter III, Section 393.94, 10- 1-89 Edition.

f. There shall be an adjustable rear view mirror with a flat glass area of at least 60 square inches (385 cm2) on each side of the vehicle. In addition to each flat mirror, a wide angle convex mirror of at least 7 square inches (45 cm2) shall be provided. Power adjustable and heated mirrors may be specified.

g. There shall be at least one front overhead or two side mounted (one each side of windshield) mirror(s) to provide the vehicle operator a clear view of the area in front of the vehicle that is not within the operator's direct view.

(1) The lateral field of vision shall be at least h. A cab roof hatch may be requested if manual 90 degrees left and right of center. roof turret operation from outside the cab is an

AC 150/5220-IOB 10/20/97

operational requirement for the particular turret specified.

29. EQUIPMENT. The following shall be provided as applicable:

Air Conditioner, if specified. Cab Dome Light. Crew Seats(s) with approved 3-point seat belts. Driver's Enhanced Vision System (DEVS), if

specified. Driver's Seat, up and down and fore and aft

adjustable bucket type with approved seat belt. HeaterlDefroster with 200 BTU output per cubic

foot of cab space, with blower capacity equal to I cab volume per minute, with fresh air intake, and with ducts to windshield. Mounting provisions for SCBA at/in each seat. Siren/Audible Emergency Warning Device. Sun Visors - two or more. Windshield Deluge System, if specified. Windshield Washers - two or more with large

capacity reservoir. Windshield Wipers - two or more with delayed

and mUlti-speed capability.

CANCELLED

30. INSTRUMENTS AND WARNING LIGHTS. The following instruments and warning lights shall be provided in the cab as applicable:

Air Pressure (brake and other air-driven

accessories) Switch for Amber (yellow) Beacon Indicator. Complimentary Agent Tank - Charged Light. Differential Lock Indicator. Emergency Beacon Indicator.

Engine Coolant Temperature. Engine Oil Pressure. Engine Tachometer(s). Foam Agent Tank Level Indicator with test switch. Foam Pump Pressure Indicator Fuel Level. Headlight Beam Indicator. High Reach Turret Deployment Indicator, if

specified. Low Air Pressure Warning. Low oil pressure/high water temperature

audible/visual alarm. Low engine coolant audible/visual alarm. Speedometer/Odometer. Side/slope inclinometer. Voltmeter - Expanded Scale. Water Pump Pressure. Water Tank Level Indicator with test switch.

Section 4. Driveline and Controls.

31. AXLES.

a. The axles shall be rated and certified as required by paragraphs 100.a.(l ) and 103.a as being suited for the intended use. The axle manufacturer's approved rating shall not be raised by the vehicle manufacturer to conform to the requirements of this specification.

b. Front and rear axles shall have adequate capacity to carry the fully loaded vehicle under all intended operating conditions. The maximum variation in axle tread shall not exceed 20 percent of the tire(s) sectional width at rated load.

c. Tractive power at each wheel shall be achieved by use of torque proportioning differentials or

other suitable automatic devices which will ensure that each wheel of the vehicle is driven independently of the other wheels.

d. Front axles shall be equipped with steering drive ends designed to eliminate fluctuations in angular velocity of the wheels when cramped either left or right at all normal operating speeds.

32. BRAKE SYSTEM. A brake system shall be provided which has been tested and certified in accordance with the applicable requirements of paragraphs 104, l OS, and 106. The system shall include an all-wheel, split-circuit, power-assisted service brake, a modulatable emergency brake, and a parking brake.

a. Air supply. Vehicles supplied with air brakes shall have:

(1) A compressor that shall:

(a) Be engine driven.

capacity

c.

10/20/97 AC 150/5220-10B

(b) Have capacity sufficient to increase air pressure in the supply and service reservoirs from 85 to 100 psi, (552 to 690 kPa) when the engine is operating at the vehicle manufacturer's maximum recommended revolutions per minute, in 25 seconds or less.

(c) Have the capacity for quick buildup of tank pressure from 5 psi (35 kPa) to the pressure required to release the spring brakes within 12 seconds.

(d) Have an automatic air drying system immediately downstream from the compressor.

(2) A service air reservoir that shall:

(a) Have a volume at least twelve times the total combined brake chamber volume at full stroke. If the reservoir volume, inclusive of supply lines, and air dryer volumes, is greater than the minimum required, proportionately longer buildup time is acceptable using the following formula:

Maximum Time (sec) = Actual reservoir x 25 Required reservoir capacity and

(b) Have drain(s) and safety valve(s) as necessary for safe and efficient operation. Drains shall be at the lowest point of the vehicle.

(3) When specified by the purchaser, a provision for charging of air tanks by a vehiclemounted auxiliary compressor. If an auxiliary compressor is specified, there shall be a pull-away electrical connection for plug-in station electricity to power the compressor.

(4) When specified by the purchaser, a pullaway air connection for charging of air tanks from an external air source.

(5) Visual and audible low air pressure warning devices. The low pressure warning device

CANCELLED

(2) The emergency brake shall be capable of meeting the emergency brake stopping distance standard of Table 2, Performance Parameter 1 1 , with the failure of a single part in the service brake system; other than a common valve, manifold, brake fluid housing, or a break chamber housing.

c. Parking Brake. The parking brake shall be operable by the driver and shall meet the parking brake holding performance standard of table 2, Performance Parameter 12.

d. Service Brake. A service brake powered by air, hydraulic, or air over hydraulic, which meets the applicable performance standards of table 2, shall be acceptable.

(1) A chamber shall be provided for each brake for each wheel and shall be mounted so that no part of any chamber hangs below the bottom of the axle on which it is mounted.

(2) The service brake shall be capable of providing at least one power-assisted stop with the vehicle engine off, which meets the service brake stopping distance standard of Table 2, Performance Parameter 10.

e. Anti-Lock Brake System (ABS) - Option When specified by the purchaser, an all wheel ABS may be installed.

33. STEERING . All classes of vehicles shall have power-assisted steering.

a. The power assist shall have sufficient capacity so that no more than 15 pounds (6.8 kg) pull is necessary on the steering wheel rim to tum the vehicle wheels from lock to lock.

b. The design of the steering mechanism shall permit manual steering to bring the fully loaded

vehicle to a safe stop after power-assist failure.

shall be visible and audible from the inside of the cab. The vehicle shall perform as follows when driven on a steering pad around a 100-foot (30 m) b. Emergency Brake. radius circle:

(1) The emergency brake shall be operable by (1) With increasing speed, the steering angle the driver and shall be capable of modulation through shall increase; oversteer is not acceptable. the use of the service brake control.

(2) The vehicle shall remain on the prescribed path until achieving a speed at least equal to

AC 150/5220-IOB

the standard specified in Table 2, Perfonnance Parameter 3, applicable to its class.

d. The wall-to-wall turning diameter shall be no grater than three times the length of the vehicle.

34. SUSPENSION.

a. The axles and suspension system shall be such that the total unsprung weight of the vehicle will not be

greater than 20 percent of the in-service vehicle gross weight.

b. Double acting hydraulic shock absorbers or an equivalent energy adsorbing device shall be provided for all axles or bogies as applicable.

c. Energy absorbing stops shall be installed so as to prevent damage to axles, drive shafts, engine oil pan, or any other portions of the chassis from bottoming.

35. TRANSFER CASE.

a. The transfer case shall be certified as suitable for the intended service in accordance with the requirements of paragraph 103.

b. A transfer case, which is either separate or integral with the transmission, shall be acceptable.

c. A single or a two-speed transfer case, as required to meet the perfonnance requirements, shall be acceptable.

d. A transfer case which has either a front axle disconnect, a center differential with automatic or manual lockout, or an overriding clutch to compensate for difference in travel between front and rear wheels, shall be acceptable.

e. A transfer case which either engages the front and rear axles at all times, engages all axles automatically, or which is driver-operator selectable to engage all-wheel drive and which will not allow the vehicle to stall as long as the tires of engaged axle(s) have traction, shall be acceptable.

36. TRANSMISSION.

a. The transmission shall be certified as suitable for the intended service in accordance with the requirements of paragraph 103.

b. The transmission shall be a continuous drive system. Either hydrostatic, hydrostatic/automatic, or automatic powershift, incorporating a torque converter with suitable torque ratio, shall be acceptable. The use of a transfer case to achieve the required perfonnance is acceptable.

c. The transmission range selector shall have all positions clearly identified and back lit.

d. All drive-line components shall be of the same power ratings, i.e., no reduction in transfer through bulkheads.

e. The hydraulic system shall include oil pumps, oil filter and screens, a hydraulic control system, and an oil cooling system capable of limiting the transmission temperature to the maximum recommended by the transmission manufacturer.

f. In addition to meeting the acceleration, gradability, and top speed standards of paragraphs 5 1, 55, and 57, the transmission shall have sufficient spacing of intennediate ranges to provide a smooth, unifonnly spaced transfer of power over the entire operating range.

g. When electronically provided.

specified controlled

by the purchaser, transmission shall

37. WHEELS AND TIRE ASSEMBLY.

an be

a. The wheel and tire assembly, including the recommended tire inflation pressure, shall be certified in accordance with paragraph 103 as being suitable for the intended service.

b. Rim and tire rating shall confonn to FMVSS 1 19, 120, and applicable tire and rim association recommendations for the type and size of tires furnished.

c. All tires, rims, and wheels shall be identical.

d. The tires shall provide good lateral stability during off-road mobility use in the terrain and climatic conditions expected at the intended airport. They shall also demonstrate safe on-road handling characteristics for operation on wet pavement.

CANCELLED

e. Tires shall have a rated capacity at least equal to the load imposed on each tire measured at each wheel at the ground.

f. Tires shall be repairable and replaceable. There shall be a spare tire and wheel/rim assembly provided with, but not mounted on the vehicle.

NOTE: The principle objective in the selection of the wheel and tire assemblies is to enhance the offpavement mobility performance on the terrain encountered at the intended airport and, at the same

AC 15015220-10B

time, meet highway automotive performance standards. However, the off-pavement mobility and overall handling characteristics of a vehicle depend on a number of other factors in addition to tire selection. Additional information to aid the purchaser during specification development, as well as during consultations with the vehicle and tire manufacturers, is provided in appendix 2.

g. When specified by the purchaser tires shall include beadlocks.

Section 5. Electrical System.

38. COOLANT HEATER. An engine coolant preheating device with thermostat shall be provided. It

shall have sufficient capacity to maintain the engine at the manufacturer's recommended temperature for rapid starting and immediate high initial engine performance.

39. LIGHTING AND MARKING SYSTEM.

a. The lighting and marking system, including reflectors, beacons, and clearance lights, shall satisfy the applicable State and Federal safety standards.

b. The system shall include:

(1) Two or more sealed beam, halogen headlights with upper and lower driving beams.

(2) Spotlight mounted on any turret.

(3) At least one taillight and one stoplight, or one combination taillight/stoplight on each side of the rear of the vehicle.

(4) Tum signals, front and rear, with selfcanceling control, a visual as well as audible indicator, and a four-way flasher switch.

(5) Reflectors, markers, and clearance lights as applicable.

(6) Engine compartment light(s), non-glare type, arranged to illuminate both sides of the engine with switches(s) located in the engine compartment.

(7) Two backup lights, one installed on each side of the rear of the vehicle.

(8) One or more emergency flashing beacons as needed to meet visibility requirements. For recognition, the color red shall be used as stand-alone or in combination.

(9) Compartment light(s), non-glare type, arranged to illuminate the inside of all storage, maintenance access, and piping compartments.

c. Optional:

(1) Spotlights, quartz lights, fog lights, and area/service lighting, as specified, shall be included ..

(2) If under normal local operational procedures there are circumstances where it is desirable to identify the status of an ARFF vehicle as other than an ARFF vehicle in emergency response status, at least one amber (yellow) flashing beacon, if requested, shall be provided in addition to the requirements of paragraph 39.b.

40. POWER SUPPLIES.

a. All components such as alternator, circuit breakers, etc., shall be as waterproof/water resistant as the state-of-the-art permits without the use of marine quality components. They shall be accessibly mounted and protected against exterior and engine heat.

b. One of the following electrical systems shall be provided:

(1) 12-volt electrical and starting.

(2) 12-volt electrical/24-volt starting.

1 1

CANCELLED

AC 150/5220-10B

(3) 24-volt electrical and starting.

c. For 12-volt systems, an alternator shall be provided which has a minimum curb idle charging rate of 160 amps. For 24-volt systems, an alternator shall be provided which has a minimum curb idle charging rate of 80 amps. In either case, the alternator shall have a total current output capacity adequate to service the full operational electrical load. It shall have automatic regulation.

NOTE: Provisions to handle the additional load imposed by the winterization kit and/or air conditioning shall be included, when appropriate.

d. A weatherproof, grounded, polarized male plug (or plugs as required to service the anticipated electrical load), suitable for receiving l lO-volts AC from an outside electrical supply, shall be provided.

(1) The plug(s) shall be mounted as specified by the purchaser.

(2) The plug(s) shall be wired to a built-in battery conditioner, the engine coolant pre-heating device, and the on-board air compressor, if specified.

(3) The plug(s) shall be designed to breakaway or auto-eject.

(4) The matching female receptacle(s) shall be provided with the vehicle.

e. A battery system shall be provided as follows:

(1) The system shall contain at least two 12volt batteries connected in an approved manner.

(2) Sufficient cold cranking battery capacity shall be provided to meet the engine manufacturers recommendation for the lowest ambient starting temperature.

(3) If a 24-volt starter is specified, the system shall include a solid-state battery circuit connection for the starter.

NOTE: Additional or larger capacity batteries may be necessary on vehicles equipped with the optional winterization kit.

1 0/20/97

(4) Batteries shall be securely mounted and protected against mechanical damage, water spray, and

engine and exhaust heat.

f. If an enclosed battery compartment is provided, it shall be adequately ventilated. The battery connections and the batteries shall be readily accessible for removal and installation, as well as for examination, test, and maintenance. Roll out trays are an acceptable means Of providing the required accessibility .

41. STARTER. An electric starting device shall be provided. When operating under maximum load, the current draw shall not cause a voltage drop sufficient to adversely affect the function of other electrical equipment required to be operational during the start up process.

42. WIRING.

a. All wiring shall be numbered or color coded for proper identification, stranded conductors, and of a wire gauge commensurate with the anticipated maximum electrical load of the circuit.

b. Wires shall be insulated in accordance with the applicable standards of the Society of Automotive Engineers (SAE).

c. All connections shall be made with lugs or terminals mechanically secured to the conductors.

d. Wiring shall be protected from heat, oil, lubricants, fire fighting agents, and physical damage and secured in place. Appropriate circuit breakers shall be provided. Circuit breaker panels shall be easily accessible for service. A diagram and labeling scheme shall be affixed to the inside of the removable or hinged panel over the breakers. A copy of this diagram shall also be included in the maintenance manual.

43. RADIO INTERFERENCE. Radio suppression of electrical system interference shall be in accordance with SAE J 55 1, Standard on Performance Levels and Methods of Measurements of Electromagnetic Radiation from Vehicles and Devices (20-1000 MHz) or an equivalent radio interference suppression standard.

CANCELLED

10/20/97 AC 150/5220-1 0B

Section 6. Engine and Accessories.

44. COOLING SYSTEM.

a. The vehicle manufacturer shall certify and provide appropriate documentation in accordance with paragraph 100.a.(2) and 104, that the complete cooling system installation is suitable for the intended service.

h. The cooling system shall be provided with an automatic thermostat.

c. If a liquid-cooled system is provided, it shall:

(1) Have the capacity to stabilize the engine coolant temperature within the engine manufacturer's prescribed limits under operational conditions at the ambient temperature range normally encountered at the airport.

(2) Have drain cocks installed at the low point of the cooling system and at such other points as may be necessary to drain the system completely.

d. If an air-cooled system is provided, it shall have the capacity to stabilize the cylinder head and oil temperatures within the engine manufacturer's prescribed limits under operational conditions at the ambient temperature range normally encountered at the airport.

e. When provided, radiator or air inlet shutters shall be automatic and shall be "fail safe" in the open position.

45. EXHAUST SYSTEM.

a. The vehicle manufacturer shall certify that the exhaust system is suitable for the intended service.

h. The engine exhaust system shall be constructed of rust-resistant materials and shall be designed and installed so as to prevent the discharge of exhaust towards the ground, engine or cab air intake, or onto vehicle tires.

c. The exhaust system exit shall be located to prevent exhaust gasses from entering the closed cab under all operational conditions and shall include a muffler.

d. System components shall be protected from damage that could result from traversing off-road terrain.

e. Environmental requirements. ARFF vehicle/ engines must meet all applicable Federal emission standards and regulations, e.g., 40 CFR Part 89, and EPA Off-Road emissions standards.

46. FUEL SYSTEM.

a. The vehicle manufacturer shall provide a fuel system which meets the engine manufacturer's installation approval and shall certify that the fuel system is suitable for the intended service.

h. All components shall be installed in a protected location or otherwise protected from operational damage, exhaust heat, and exposure to ground fires.

c. The fuel tank(s) shall:

(1) Be constructed of an approved material.

(2) Have an accessible drain plug.

(3) Have a filler pipe (accessible from outside of the cab) that is at least 2.25 inches (5.7 cm) in diameter.

(4) Have sufficient capacity to provide for a minimum of30 miles (48 km) of highway travel at 45 mph (73km/h) average plus 2 hours of pumping at the full rated discharge.

(5) Be so located and mounted that it will prevent gravity feed.

d. An approved filter, mounted in an accessible location, shall be provided for each fuel supply line. The fuel supply line filter should be installed in such a manner that allows the free flow fueling of the vehicle without causing back ups and spills.

e. A heated fuel/water separator in connection with a winterization kit when specified by the purchaser shall be provided.

47. GOVERNOR. An engine governor, which will not adversely affect the automotive or extinguishing

1 3

CANCELLED

AC 150/5220-IOB

agent system performance, shall be provided. It shall be set to limit engine speed so that it cannot exceed the maximum rpm recommended by the engine and drive line component manufacturers.

48. LUBRICATION.

a. The engine and transmission shall operate efficiently and without detrimental effect to any drive train components when lubricated with standard commercially available lubricants in accordance with recommendations of the engine and transmission manufacturers.

b. The engine oil and transmission fluid filters shall be full-flow type with replaceable spin-on element.

c. All moving parts requiring lubrication shall have a means provided for such lubrication. There shall be no pressure lubrication fittings where their normal use would damage grease seals or other parts.

d. The vehicle shall be serviced prior to delivery with lubricants, brake and hydraulic fluids, and a cooling system fluid suitable for use in the temperature range expected at the purchaser's airport.

49. POWER REQUIREMENT.

a. The engine(s) shall be an internal combustion diesel capable of developing the torque and horsepower needed to meet the automotive performance standards

of table 2 and the extinguishing agent discharge performance standards of table 3 for the applicable vehicle class. This power requirement shall be achieved without exceeding a "no load" governed speed at the peak of a certified gross brake horsepower (bhp) curve.

b. The engine shall be capable of meeting the specified performance standards while operating on commercial grade diesel fuel.

50. WINTERIZATION -- OPTIONŀ

a. Vehicles purchased for use in areas where it is common industrial practice to winterize vehicles shall have a winterization kit installed.

b. The winterization kit shall not detract from the performance of the vehicle or the fire fighting

system in ambient temperatures up to 1 15° F (43.5° C).

c. The winterization kit shall provide sufficient insulation and heating capacity, by means of hot circulating liquids and forced air heat exchangers, to permit satisfactory operation of the vehicle and firefighting systems for a period of at least 2 hours at ambient temperatures as low as -40°F (-40° C) with the vehicle fully operational and the engine running. At the end of this 2-hour period, the vehicle shall be capable of successfully discharging its agent(s).

Section 7. Automotive Performance.

51. ACCELERATION. Each vehicle shall meet the applicable standard of Table 2, Performance

Parameter 9.

52. BRAKE SYSTEM. The stopping and holding performance for each type of brake for each vehicle class shall meet the applicable standards of table 2, Performance Parameters 10, 1 1, and 12.

53. DYNAMIC AND STATIC STABILITY. The

unanticipated stream interruption or vehicle instability. Pumping capacity shall supply an intermittent discharge as desired.

b. Remain stationary while headed in either direction across a 20 percent (or 12°) side slope and while the steering is being moved to a maximum turning angle both right and left without any vehicle instability .

vehicle shall be able to: c. Meet the applicable side slope stability

a. Pump while rolling in both directions across a 20 percent (or 12°) side slope with extinguishing agents being discharged in any direction of turret azimuth at maximum rated turret capacity without

standard of table 2, Performance Parameter 2.

d. Meet the applicable dynamic balance standard of Table 2, Performance Parameter 3.

CANCELLED

. 10/20/97

54. ENVIRONMENTAL CONDITIONS. The vehicle shall be capable of withstanding the following conditions without detrimental effect to subsequent

operation of the vehicle or any of the fire extinguishing systems:

a. Dust particles as encountered in desert areas.

b. The corrosive effects of salt fog.

c. Material decay from fungus and mildew.

d. Relative humidity up to 100 percent, as well as wind driven snow, sleet, rain, and vehicle selfsplashing of water.

e. Ambient temperature ranging from 32°F to 1 15° F (O°C to 43.5° C). (See paragraph 50 for winterization). If winterization is necessary, the temperature performance range shall extend to at least

_40° F (-40° C).

55. GRADABILITY. The vehicle shall be able to:

a. Ascend a smooth, dry, paved road having a 20 percent grade and maintain a speed of at least 8 mph (13 km/h).

b. Ascend, stop, start, and continue ascending; and descend, stop, start, and continue descending on a 20 percent grade at a speed of at least 2 mph (3.2 km/h) with extinguishing agents being discharged at maximum rated capacity from the primary turret(s).

c. Ascend and descend a dry, hard surface incline having a 50 percent grade at not less than 1 mph (1.6 km/h).

d. Climb a vertical wall at least 18 inches (45 cm) high and negotiate terrain which will deflect the opposite wheels of the truck in alternatively contrary directions at least 14 inches without the remaining wheels loosing traction.

56. OPERATIONAL RANGE. The fully loaded vehicle shall be able to:

a. Operate continuously for 25 miles (40 km) at speeds up to 60 mph (96 km/h). The test route shall include agricultural lands, paved and unpaved roads, and grades typical of those encountered at the intended airport. During this performance evaluation, the

AC 150/5220-IOB

vehicle shall operate in all-wheel drive. At least 5 miles (8 km) of this operation shall be "off-road" travel.

b. Operate on smooth, dry, level pavement through a range from 1 mph (1.6 km/h) to at least 10

mph (16 km/h) while discharging agents from the primary turret(s) at rated maximum capacity without interruption.

c. Negotiate pooled water to a depth of 2 inches (5 cm) for a distance of at least 150 feet (45 m) at a speed of at least 40 mph (65 km/h) without engine flooding/stalling, loss of directional control, loss of braking, or electrical system(s) shorting.

d. Operate for 10 minutes on dry, paved roadway at not more than 2 mph (3.2 km/h) at an engine speed that does not result in rough, irregular operation.

e. Ascend dry, paved incline having an 8 percent grade for a distance of one-quarter mile (0.4 km) at a speed of not less than 20 mph (32 km/h).

57. TOP SPEED. The vehicle shall be able to consistently reach a top speed of 65 mph (104 km/h) and maintain a constant speed of at least 60 mph (96 km/h) on typical paved, level (grades of less than 1 percent) highway surfaces for a minimum distance of 20 miles (32 km) without showing overheat symptoms in any portion of the cooling system or power train.

58.0FF-ROAD HIGH MOBILITY SUSPENSIONS An off-road, high mobility suspension system such as independent, active/reactive, and articulated suspensions, combined with lowering of the vehicle center of gravity, when specified:

a. To include a central tire inflation/deflation system when specified, should support an off-road response at 35 mph when operating within the runway safety area over similar terrain in close proximity to the improved surface areas of the airfield. Typically this area has been moderately graded, has had most major obstruction removed, and has a sod cover.

b. The applicable test for this performance is no more than 0.5 g rms acceleration at the seat of the vehicle when traversing an 8 inch (24 cm) half round at 15 mph (24 km/h).

CANCELLED

AC 150/5220-10B

59. DRIVER'S ENHANCED VISION SYSTEM (DEVS). DEVS equipment can aid normal operations and provide an additional margin of safety for airport rescue response during periods of very low visibility operations. The DEVS equipment, when justified, will improve emergency response time during

periods of low visibility , reduce the probability of secondary accidents often associated with poor weather and low visibility conditions, and improve command and control in the event of an aircraft incident or accident. DEVS normally consists of three subsystems: night vision, navigation, and tracking. Because of the complexity of a DEVS, procurement and installation may be optional and by separate contract and comply with AC 150/52 10- 19.

a. Night vision. The purpose of the night vision subsystem is to improve the ARFF vehicle driver's ability to see at night and through smoke, fog, and adverse weather; it consists of a Forward Looking

InfraRed (FUR) camera and a monitor in the cab. The vehicle shall be fitted with this subsystem.

b. Navigation. Using a differential GPS and a moving map display inside the cab, the navigation subsystem shows ARFF vehicle drivers their location, the accident site, and the path between to ensure rapid advance toward the site. The vehicle shall be fitted with this subsystem if specified by the purchaser.

c. Tracking. The vehicle tracking subsystem allows an overview of all vehicles at the command center and provides reliable digital communications with vehicles. It is comprised of a display at the command center and a digital radio datal ink between the command center and vehicles. The vehicle shall be fitted with this subsystem if specified by the purchaser.

60. THROUGH 69. RESERVED.

CANCELLED

10/20/97 AC 1 5015220-10B

Table 2. Automotive Performance Standards

PERFORMANCE PARAMETER FOR

FULLY LOADED VEHICLE VEHICLE CLASS ----

I . Minimum Rated Water Capacity: (gallons) 1,000 1 ,500 2,500 3,000 and above

2. Side Slope Stability: Degrees 30° 28° 28° 28°

Percent Grade 58% 53% 53% 53%

3. Dynamic Balance: Minimum Speed 22 22 1 8.5 1 8.5

on 100 ft. Radius Circle (mph)

4. Approach and Departure: Angles 30° 30° 30° 30°

5. Interaxle Clearance: Angle 12° 12° 12° 12°

6. Underbody Clearance: 1 8" 1 8" 18" 1 8"

7. Underaxle Clearance at Differential 13" 13" 13" 13" Housing Bowl:

8. Wall-to-Wall Turning Diameter: Less than 3 x vehicle length

9. Maximum Acceleration Time from 0 to 50 25 30 40 45 mph: Seconds

10. Service Brake:

Stopping Distance From: 20 mph Maximum 35 feet 40 40 feet 40 mph Maximum 1 3 1 feet 160 160 feet

Hold Fully Loaded Vehicle: Minimum 50 percent grade Ascending and Descending

1 1 . Emergency Brake: Maximum 288 Feet Stopping Distance From 40 mph

12. Parking Brake: Minimum 20 percent grade Hold Fully Loaded Vehicle: Ascending or descending

CANCELLED

AC 150/5220-10B 10/20/97

Table 2M. Automotive Performance Standards (Metric)

PERFORMANCE PARAMETER FOR

FULLY LOADED VEHICLE VEHICLE CLASS ----

I . Minimum Rated Water Capacity: (Liters) 3 785 5 678 9 463 I I 355

and above

2. Side Slope Stability: Degrees 30° 28° 28° 28°

Percent Grade 58% 53% 53% 53%

3. Dynamic Balance: Minimum Speed on 35 35 29.5 29.5 30 m. Radius Circle (kmlh)

4. Approach and Departure: Angles 30° 30° 30° 30°

5. Interaxle Clearance: Angle 12° 12° 12° 12°

6. Underbody Clearance: (cm) 46 46 46 46

7. Underaxle Clearance at Differential 33 33 33 33 Housing Bowl: (cm)

8. Wall-to-Wall Turning Diameter: Less than 3 x vehicle length

9. Maximum Acceleration Time from 0 to 80 25 30 40 45 kmlh: Seconds

10. Service Brake:

Stopping Distance From: 32 kmlh Maximum 1 1 m 14 14 m 64 kmlh Maximum 40 m 48 48 m

Hold Fully Loaded Vehicle: Minimum 50 percent grade Ascending and Descending

I I . Emergency Brake: Maximum 86 m Stopping Distance From 64 kmlh

12. Parking Brake: Minimum 20 percent grade Hold Fully Loaded Vehicle: Ascending or descending

1 8

CANCELLED

10/20/97 AC 150/5220-1 DB

CHAPTER 3. FIRE EXTINGUISHING SYSTEMS.

Section 1. Dry Chemical - Option.

70. AGENT CONTAINER(S) AND COMPONENTS.

a. The dry chemical container(s) shall:

(1) Be constructed and stamped in accordance with the ASME "Code for Unfired Pressure Vessels."

(2) Be certified in accordance with paragraph 103 .c.

(3) Be able to hold at least 450 usable Ibs (204 kg) of a potassium-based dry chemical fire extinguishing agent.

(4) Have an accessible fill opening that is easy to open and close and be provided with a

compatible funnel to permit filling from dry chemical storage containers. The overall design shall allow filling without the removal of any of the extinguisher piping or any major component other than the fill cap.

(5) Have a pressure relief device conforming to appropriate ASME codes that will protect both the container and the low pressure piping.

(6) Have a gauge that indicates the pressure in the agent container at all times.

b. A check valve shall be provided in the gas piping to prevent the agent from being forced back into the propellant gas line.

c. A quick-acting agent system activation control shall be accessible to the seated driver and at least one other crew position. A similar control shall be located near the agent handline.

d. The agent pressurization system shall ensure fluidization of the dry chemical at the time of activation. Designs which include the automatic movement of the chemical or chemical container to help fluidize the contents shall also include a manual operating feature.

e. There shall be provisions for purging agent from all piping and hose after use without discharging the remaining chemical. Also, there shall be

provisions for the depressurization of the chemical container without the loss of the remaining chemical.

71. AGENT DELIVERY PIPING AND VALVES.

a. The piping, couplings, and valves shall be sized to provide the gas flow into the system and the agent flow out of the chemical container needed to meet the requirements of table 3, Performance Parameter I .a and b.

b. All piping and fittings shall conform to the appropriate AŰME code. The completed system shall be designed and installed so as to withstand the recommended working pressure of the system.

c. The integrity of the installed discharge piping shall be tested at a pressure equal to 150 percent of the system working pressure.

d. Material for all piping, couplings, and valves shall be resistant to agent, weather, and galvanic corrosion.

e. Piping shall be securely mounted and provided with flexible couplings where needed to minimize stress.

f. When more than one agent discharge outlet is provided, the size and design of piping, pressure regulators and fittings shall provide equal flow to each handline nozzle, regardless of the location of the hose reel or the number of lines placed in operation.

g. All valves shall be quarter-tum type, selected for ease of operation and freedom from leaks.

72. PROPELLANT, PROPELLANT CONTAINERS AND COMPONENTS.

a. The propellant gas shall be either dry nitrogen or dry air. Sufficient container capacity shall be provided to ensure enough gas to discharge all of the agent and to permit purging of all pipes and hose lines after use.

b. All propellant gas cylinders and valves shall comply with US Department of Transportation (DOT) requirements. Cylinders shall bear the DOT marking,

CANCELLED

AC 150/5220-IOB

including evidence of a current hydrostatic test and shall be certified in accordance with paragraph 103.f.

c. Pressure gages shall be provided which will indicate the pressure on the propellant gas system downstream of the pressure regulator and in the propellant cylinders at all times.

d. Cylinder valves, gages, and plpmg shall be arranged or protected to preclude accidental mechanical damage during firefighting operations.

e. The pressure reduction system shall automatically reduce the normal storage cylinder pressure to (and hold it at) the designed operating pressure of the dry chemical container. The regulator may be of a type without pressure indicating gages.

(1) Pressure regulating devices shall be equipped with a spring-loaded relief valve that will relieve any excess pressure that may develop in the regulator.

(2) All pressure regulating devices shall be sealed or pinned at the designed operating pressures after final adjustment by the system manufacturer and shall be certified in accordance with paragraph 103.g.

(3) Regulators must be of a high flow variety which allows a rapid build-up time for system pressure for a full system charge and operation.

f. When specified, a hoist shall be provided to aid in propellant cylinder removal. The hoist shall be manual or electric, as specified by the purchaser.

Section 2. Halotron I or an Acceptable Substitute - Option.

73. AGENT CONTAINER AND COMPONENTS.

a. The container material shall be suitable for the storage of Halotron I or an acceptable substitute and shall be constructed in accordance with ASME "Code for Unfired Pressure Vessels" and shall be so stamped.

(1) The capacity of the container shall be as specified by the purchaser.

(2) A fill coupling of sufficient size to allow agent tank filling, without loss of agent, shall be provided. It shall permit tank filling without the removal/disconnection of any plpmg or major components. The fill coupling shall be provided with a dust cap secured to the coupling with a safety chain.

(3) A means shall be provided to determine the contents of the container as a guide in recharging partial loads and to prevent overfilling of the tank.

(4) The container shall have a gauge that indicates the pressure in the agent container at all times.

h. A means of pressure relief conforming to appropriate ASME codes shall be provided for the

chemical container and piping. A check valve shall be provided in the gas piping to prevent agent from being forced back into the propellant gas line.

c. Provisions shall be made for the purging of agent from the discharge piping and hose without discharging the chemical remaining in the container. Provisions also shall be made for the depressurization of the chemical container without the loss of the remaining chemical.

74. AGENT DELIVERY PIPING AND VALVES.

a. The piping, couplings, and valves shall be sized to provide the gas flow into the system and the agent flow out of the chemical container needed to meet the requirements of table 3, Performance Parameter 2.

h. The applicable requirements of paragraph 7 1 .b through 7 1 .g also apply.

75. PROPELLANT, PROPELLANT CONTAINERS, AND COMPONENTS. The requirements of paragraph 72 also apply here.

CANCELLED

10/20/97 AC 150/5220- 10B

Section 3. Foam Concentrate System.

76. CONCENTRATE PROPORTIONER.

a. A foam concentrate proportioning system shall be provided to control the ratio of foam concentrate to water in the foam/water solution being discharged from all orifices nonnally used for ARFF operations.

(1) The proportioning system for a 6 percent concentrate shall be sufficiently accurate to provide for the discharge of finished foam within the range of 5.5 percent to 7.0 percent foam concentrate in the discharged foam/water solution.

(2) If a foam concentrate other than 6 percent is used, the precision range shall be modified in direct ratio. Thus, a 3 percent concentrate shall be in the 2.8 to 3.5 percent concentrate range in the discharged

solution. A 1 percent concentrate shall be in the 0.92 to 1 .2 percent concentrate range in the discharged solution.

h. This precision shall be maintained for all individual discharges, and for the maximum simultaneous discharge rate of all turrets, handlines, and ground sweeps while delivering the quantity of concentrate required to meet the agent discharge requirements oftable 3.

77. CONCENTRATE RESERVOIR AND PIPING.

a. Materials used in reservoir construction and piping shall be compatible with the foam concentrate, the foam/water solution, and water.

h. A rigid or a flexible foam concentrate reservoir shall be acceptable.

(1) If separate from the water tank, the reservoir shall be mounted in a manner that limits the transfer of the torsional strains from the chassis to the reservoir.

(2) The reservoir shall be separate and distinct from the crew compartment, engine compartment, and chassis. It shall be removable as a unit.

(3) The reservoir(s) shall have a working capacity sufficient for two tanks of water based on the use of 6 percent foam concentrate. If a 3 percent foam

concentrate is specified, the working capacity of the foam tank shall not exceed that required to mix with four tanks of water or six tanks of water with a

1 percent concentrate. The actual capacity needed to comply with the perfonnance requirements will depend on the water tank capacity and the proportioner accuracy.

(4) A flexible reservoir shall be supported in a manner that does not depend on the fluid level in either the foam or water reservoirs for its structural integrity.

(5) Provisions shall be made for access for internal and external inspection and service. Reservoirs, large enough to require baffles, shall be provided with access to each baffled compartment. NOTE: In case of life time warranted poly tanks, there is no need to provide inspection access unless specified by the purchaser.

(6) The reservoir shall be fitted with a sump, complete with antiswirl baffles, and a 1 .5 inch (38 mm) minimum diameter drain with a valve and an accessible control.

(7) The reservoir outlet(s) shall be located above the bottom of the sump and shall pennit a continuous flow of foam concentrate to the proportioning system with that system supporting the discharge standards of table 3 during the discharge of two consecutive tanks of water.

(8) Reservoirs shall be vented to pennit the required fill rate without exceeding the design working pressure and to pennit emptying at the maximum design flow rate without danger of collapse. The vent outlets shall be directed so as to prevent spillage of foam concentrate on vehicle components.

c. The fill system shall be capable of delivering foam concentrate to the reservoir at a rate at least equal to the maximum use rate of the foam proportioning system.

(1) Bottom fill connection(s) shall be provided and shall be no more than 60 inches (150 cm) from the ground. The inlets shall be fitted with stainless steel strainers of 1/4 inch (6 mm) mesh, and shall have check valves or be so constructed that no more than .25 gal (1 L) of foam is lost from the

CANCELLED

AC 1 50/5220-lOB

reservoir during connection or disconnection of the foam resupply line. An isolation valve shall be installed on the foam line as it leaves the tank to allow easy maintenance on foam plumbing.

(2) A top fill opening shall be provided which shall be equipped with a No. 10 gauge mesh, corrosion resistant (stainless steel or equal) screen, and a sufficient number of 5-gallon agent container openers to permit the rapid emptying of 5-gallon containers into the reservoir(s). The fill line from the trough shall

introduce foam concentrate into the reservoir so as to minimize foaming.

d. The foam concentrate piping shall be sized to permit the flow rates needed to meet the agent discharge requirements of table 3 and shall be arranged to prevent water from entering the foam reservoir.

e. The foam concentrate piping shall be so arranged that the entire system, including any foam concentrate pumps, can be flushed with water from the water tank without contaminating the foam reservoir.

Section 4. Water System.

78. PIPING, COUPLINGS, CONNECTIONS, AND VALVES.

a. A pressure relief valve shall be fitted to the discharge system which is set to ensure discharge standards can be met and that surges above the designed operating pressure are relieved.

b. All suction and discharge outlets shall have National (American) Standard fire hose coupling threads.

EXCEPTION: Adapters, securely attached to each outlet, shall be acceptable if local couplings are not National (American) Standards as specified in NFPA 1963, Standard for Screw Threads and

Gaskets for Fire Hose Connections, and the outlet(s) with adapters do not add to the width or length of the vehicle.

c. All water system piping on the suction side of the pum p shall be tested to detect leaks. All water and

foam solution discharge piping, together with the agent pump(s), shall be tested at 150 percent of the normal system operating pressure.

d. If two pumps are used, they shall be arranged in parallel with a manifold so that either or both may supply any discharge outlet at the required operating pressure. During single pump operation, total discharge capacity may be proportionally reduced.

e. Piping, couplings, and valves shall be sized to provide agent flow to all discharge devices operating to the applicable standards of table 3.

f. A drain shall be provided in the suction system at the lowest point with a valve for draining all of the liquid from the pumping system.

g. A drainage system, with collector tubing from the low points on pump(s) and piping, shall be provided.

h. All valves shall be quarter-tum type and selected for ease of operation and leak-free design.

i. Material for all piping, couplings, and valves shall be selected to avoid corrosion.

j. Piping shall be securely mounted and provided with flexible couplings to minimize stress from chassis flexing. Union, gasketed, or victaulic fittings shall be provided where required to facilitate removal of piping.

79. WATER PUMPS AND PUMP DRIVE.

a. The water pump drive, if common with the vehicle drive, shall have sufficient power to meet the automotive performance and foam/water agent discharge standards of tables 2 and 3, individually and simultaneously, as applicable.

b. If an independent pump engine is used, it shall:

(1) Have fuel, electrical, hydraulic, and coolant requirements compatible with the chassis engine.

lubrication,

that are

(2) Have sufficient power capacity to meet the foam/water agent discharge standards of table 3

CANCELLED

10120/97

under all normal vehicle operational modes and

environmental conditions.

(3) Be certified by the manufacturer as suitable for the intended service.

c. The water pump(s) shall:

(1) Have sufficient capacity to supply the foam/water solution at the pressures and volumes required to simultaneously fulfill the discharge standards of table 3.

(2) Be a centrifugal type, single or multiple stage shall be acceptable.

(3) Be gravity primed from the vehicle reservoir, regardless of the water level in the tank, and the associated piping shall be designed and installed so as to prevent air lock. NOTE: A hydrant pressure can only be used for resupply of tank system.

EXCEPTION: If design considerations require the water pump to be mounted above the bottom of the water tank, it shall have an automatic priming system and provisions shall be made to prevent the loss of prime during intermittent pumping operations, particularly for the situation where the water level falls below the pump inlet level.

(4) Be constructed of materials which are compatible with water, water/foam solutions, and foam concentrate.

d. The design, construction, and installation of the pump, pump drive system, and associated piping and controls shall:

(1) Allow the vehicle motive drive to be engaged while pumping operations are in progress without damage to or cause lurching of the vehicle.

(2) Permit the engagement of the pump at any engine and vehicle speed combination encountered during a normal vehicle operations profile.

(3) Allow pump engagement during vehicle operations, without engine stall and without causing more than a slight and momentary reduction in the engine speed, and not cause damage to any of the components.

AC 150/5220-10B

e. A means shall be provided to automatically prevent the water pump and, if applicable, the foam pump from overheating while engaged and operating at zero discharge.

80. WATER RESERVOIR AND PIPING.

a. The water reservoir shall:

(1) Have a minimum rated capacity (working capacity) which meets the water quantity standard presented in table 3, Performance Parameter 8.

(2) Be constructed of material suitable for service with the water intended to be used by the purchaser.

(3) Have sufficient longitudinal and transverse baffies to ensure that individual baffled compartments do not exceed 350 gallons (l 324 L) and baffie openings are not in-lines.

(4) Be equipped with removable manhole covers, plates, or removable tops to permit access to the sump.

(5) Be fitted with a sump, complete with antiswirl baffies, a 2.5-inch (6.5 cm) low point drain, an isolation valve, and a quarter-tum valve which has an accessible handle.

(6) Have a top-fill opening diameter of at least 8 inches (20 cm), a screen with maximum 114 inch (6.4 mm) mesh and a gasketed, latchable cap.

(7) Be vented to permit filling and overfilling at the rate specified in paragraph 80.c and discharging in accordance with table 3, without exceeding the design operating pressure or causing the reservoir to collapse. Overflow shall be directed to the ground.

b. The discharge piping shall be sized to allow sufficient water to the pump for the simultaneous operation of all turrets, ground sweeps, handlines, and undertruck nozzles, at the applicable discharge rates specified in table 3.

c. Each connection and corresponding fill piping shall be sized to permit filling in no more than 2 minutes when the supply source provides sufficient volume at 80 psi (5.5 bar) at the reservoir fill connection.

CANCELLED

AC 150/5220-1OB 10/20/97

Section 5. Handlines, Reels, and Compartments.

81. HANDLINES.

a. There shall be a minimum of two hand lines with nozzles for the discharge of foam/water which may be of the woven jacket or reeled type (can be reeled swing out type hoses . These handlines shall not be on the same side of the vehicle. If an optional complementary agent extinguishing system is to be included, the handline may be "twinned" with one or both of the reeled foam/water handlines, or included as a separate handline as specified by the purchaser. It may be fitted with nozzles which entrain or capture dry chemical application within the master stream of water agent flow.

h. If selected by the purchaser, the reeled complementary and foam/water hand lines shall:

(1) Be able to meet the discharge performance standard of table 3, Performance Parameter 3, with the hose fully unrolled.

(2) Have at least 150 feet (45 m) of hose on each foam/water reel or each dedicated complementary

agent reel. A complementary twinned agent reel shall have at least 100 feet (30m) of hose.

(3) Be equipped with a variable pattern, N shutoff-type nozzle which will meet the discharge and pattern performance standard of table 3, Performance

Parameter 3, for both foam and water. Be certified to meet NFPA 1 964, Standard for Spray Nozzles and Tips.

(4) Electric rewind shall be provided for each hosereel when specified by the purchaser.

c. If specified by the purchaser, the woven jacket foam/water hand lines shall:

(1) Be able to meet the discharge performance standard of table 3, Performance Parameter 4, with the hose fully stretched.

(2) Have at least 1 50 ft. (45 m) of hose in each handline.

(3) Be equipped with a variable pattern, N shutoff-type nozzle which will meet the discharge and pattern performance standard of table 3, Performance

parameter 4, for both foam and water. Be certified to meet NFPA 1 964, Standard for Spray Nozzles and Tips

(4) Meet the requirements of NFPA 1961, Standard for Fire Hose.

(5) Be stored and pre connected in a hose compartment.

NOTE: See the "NOTE" following paragraph 1 l0.e.(13) for a clarification of the handline test discharge rate conditions.

82. WOVEN JACKET HOSE AND REEL HOSE COMPARTMENTS.

a. Each woven jacket hose compartment shall:

(1) Have capacity for at least 1 50 ft. (45 m) of 1 .50-in. (38 mm) mUltiple jacket hose.

(2) Be fabricated from corrosion-resistant material and designed and constructed to drain by gravity.

(3) Be smooth and free from all projections that might damage the hose.

(4) Have NO OTHER equipment mounted or located where it will obstruct the removal of the hose.

(5) Be not more than 6 ft. (1.8 m) above the ground.

(6) Have located in or adjacent to it a manually operated quarter-tum ball-type valve which controls the flow to each handline.

(7) Be weather-tight and fitted with a closure that can be secured in either the open or closed position.

h. Each hose reel shall:

(1) Be positioned to permit hose line removal by one person from any position in a 120° horizontal sector in front of the reel.

(2) Be equipped with a friction brake that will prevent the hose from unrolling when the vehicle is in motion.

CANCELLED

•

1 0/20/97

(3) Be equipped with a power rewind with manual override.

(4) Have located adjacent to it a manually operated quarter-tum ball-type valve which controls the flow to each handline.

c. Each hose reel compartment shall:

AC 1 50/5220-10B

(1) Be provided with hose rollers on the left, right, and bottom edges of the reel compartment.

(2) Be weather-tight and fitted with a closure that can be secured in either the open or closed position.

Section 6. Ground Sweep, Turrets, and Undertruck Nozzles.

83. BUMPER TURRET. A power joystick controlled bumper turret shall be provided which meets the discharge and pattern standards of Table 3, Performance Parameter 7. It shall:

a. Have controls located in the cab within easy reach of the driver and a second crew member.

b. Be capable of rotating 90 degree to either side of center.

c. Have a total traverse of 1 80 degree.

d. Be capable of elevation at least 45 degree above the horizontal.

e. Be capable of automatic oscillation through the total traverse of 1800 with controls to adjust the oscillation angles.

84. PRIMARY TURRET.

a. A manual or power-assisted turret shall be acceptable.

b. One primary turret which meets the discharge and pattern standards of Table 3, Performance Parameter 5, shall be provided. It shaH:

(1) Be capable of rotating at least 1 05 percent to either side of center.

(2) Have a total traverse of at least 210 degrees.

(3) Be capable of being elevated at least 450 above the horizontal.

(4) Be capable of both high and low flow agent distribution with a means to indicate to

driver/operator which flow pressure is being distributed.

(5) May be fitted with nozzles which entrain or capture dry chemical application within the master stream of water agent flow.

(6) Roof mounted turrets (Optional flow) may have flow rates reduced by 250 GPM increment and elect to raise ground bumper turret flow rate by 250 GPM proportionally.

C. Where turret control is at the platform, operating forces shall be less than 30 lbs. (13.5 kgt). All power-assisted controls shall have identical operating characteristics. Manual controls and overrides shall be provided at the turret platform.

d. Where turret control is in the cab, operating forces shall be less than 30 lbs. (13.5 kgt). A turret follower or other device to indicate turret azimuth and elevation shall be provided.

e. If the vehicle is equipped with a ground sweep, turrets with variable flow rates of 500 gpm (1 893 Llmin) or more shall be designed to permit selection of either 50 percent or 100 percent of the rated turret discharge.

f. If the vehicle is equipped with a bumper turret with a maximum flow rate of 300 gpm (1 137 LIm), the primary turret may be specified by the purchaser to have either a single or a dual flow rate discharge capacity .

85. HIGH-REACH, EXTENDABLE TURRET­ OPTION. The need for a practical, high-riselhighreaCh/elevating/extendible waterway (device) to replace

conventional turrets as the principle fire extinguishing agent applicator on ARFF vehicles has been recognized for over two decades. Equipment intended to provide

CANCELLED

AC 150/5220- 10B

this capability for ARFF vehicles has been under development for the past decade, and devices which are operationally practical in the ARFF service environment have become available.

a. If selected as a substitute for the primary turret by the purchaser, the device provided shall:

(1) meet the requirements of paragraphs 8- 5.2, General Requirements and 8-5.3, Capacity Ratings in NFPA 1901-1991, Section 8-5, Water Tower,

EXCEPTION: The provisions of Paragraph 8.5.3.1 do not apply; see 85.a.(3) below.

(2) meet the functional requirements of paragraph 84.a-c for a conventional roof turret except that the minimum rotation of the agent stream either side of center shall be at least 105 degree, and have a űotal traverse of at least 210 degree, with horizontal rotation of the boom assembly,

(3) meet the primary water-foam agent turret discharge requirements of Table 3, Items 5.a and b.(l )-(3) for the applicable vehicle class while in bedded position,

(4) meet the foam quality standards of table 4 for the applicable foam applicator and foam type,

(5) function during ARFF operations without the need for outriggers or other ground contact stabilizers which would render the vehicle immobile or hinder its maneuverability,

(6) achieve the elevation and reach needed to service the highest tail mounted engine for the type of aircraft being protected and start application of agent within 30 seconds of activation of the deployment cycle. The high rise, telescoping, and/or articulating movement of the boom/tower shall be accomplished with not more than two adjacent lever controls and may be manual or automated for pre-selected positioning of the elevation and reach. If automated, these functions shall be provided with a manual override positioning capability,

(7) be capable of applying agent to the interior of the aircraft through cargo bay openings, passenger doorways, and emergency exits on the type

of aircraft being protected while the aircraft is in either the gear-up or gear-down landing position, with the

vehicle positioned a horizontal distance of twenty feet from the aircraft,

(8) have a range of motion so as to permit positioning of the nozzle to direct a fire fighting agent stream at least 90 degree to the longitudinal axis of the fuselage for interior fire extinguishment,

(9) be capable of providing (the boom mechanism) for horizontal movement along the aircraft of at least 300 left and right of the vehicle centerline so as not to require repositioning or movement of the ARFF vehicle. This horizontal rotation must be accomplished without the deployment of stabilizers or outriggers which might cause a delay in positioning or emergency movement of the rescue vehicle,

(10) have sufficient back-up systems to allow for override of the single lever boom control and hydraulic system (or other power source) if the primary system becomes disabled, and

(11) may be fitted with nozzles which entrain or capture dry chemical application within the master stream of water agent flow.

b. If specififed by the purchaser as a substitute for a roof-mounted primary water/foam and a dry chemical turret, i.e., to function as a dual agent turret

system, the device shall also be capable of meeting the agent discharge performance of Table 3, Item 9.a-c while in the bedded position.

c. For man-rated or nonman-rated devices an adjustable or dual flow rate nozzle shall be provided to which will allow flow rates and patterns suitable for interior aircraft fire fighting.

d. If a man-rated device is specified by the purchaser, access and load ratings shall be adequate to

allow a properly equipped fire fighter to use the tools and water/foam or auxiliary agent handlines necessary to perform the functions associated with interior aircraft fire fighting and fight tail mounted engine fires from the fully extended device. If the device is equipped with a ladder attached to the boom or sections for continuous egress, it shall meet the requirements of paragraphs 8-5.2.5. 1 through 8-5.2.5.7 ofNFPA 1901-199 1 .

e. If a nonman-rated device is specified by the purchaser, it shall be fitted with the tools and devices

CANCELLED

needed for a driver or another operator to remotely perform the interior aircraft and tail mounted engine fire fighting functions. The following are examples of such tools/devices:

(1) Auxiliary agent line - capable of discharging either dry chemical or Halotron I or approved equivalent through an appropriate nozzle while the device is extended out and up to its maximum operational reach. It shall meet the minimum auxiliary agent flow rate and pattern requirements of Table 3.

(2) Remote optics - capable of sufficient resolution to permit overall fire scene surveillance when fully extended and to provide the driver/operator with the detail needed for placement of the penetration device on the aircraft hull for proper piercing. The camera and associated lighting shall be designed and

installed for exterior environmental operating conditions normally encountered by ARFF vehicles. A monitor (7" or larger) shall be cab-mounted in a roadworthy manner and shall be readily accessible to the driver/operator.

(3) Skin penetrator/agent applicator - for penetration of the fuselage to access passenger cabin or

AC 1 50/5220-10B

cargo compartment fires from outside the aircraft. It shall be moveable in conjunction with the water/foam nozzle to allow proper placement with the nozzle control. It shall meet the minimum water/foam flow rate and pattern requirements of table 3, Items 4.a and c.

86. UNDERTRUCK NOZZLES -- OPTION. If requested by the purchaser, sufficient foam/water undertruck nozzles shall be provided so that the combined spray pattern will cover the total undertruck area as well as the inner sides of the wheels and tires.

87. DUAL AGENT TURRET--OPTION . If specified by the purchaser, it shall:

a. meet the applicable discharge and pattern standards of table 3, performance parameters 5 and 9,

b. be capable of being depressed to discharge foam/water agent to within 30 feet (9m) of the front bumper of the vehicle at full output using dispersed stream.

Section 1. Agent System Performance.

88. COMPLEMENTARY AGENT SYSTEM -­ OPTION.

a. If a dry chemical system is provided, it shall meet the standards of table 3, Performance Parameter

1 .

b. If a Halotron I or approved equivalent substitute system is provided, it shall meet the standards of Table 3, Performance Parameter 2.

89. WATERIFOAM AGENT APPLICATORS.

a. Each water/foam agent handline shall be capable of delivering a finished foam solution which meets the applicable rate, range, and pattern standards of table 3, Performance Parameters 3 or 4.

b. Each water/foam agent handline shall deliver finished foam of a quality which meets the applicable standards of table 4.

c. Each water/foam agent turret or ground sweep shall be capable of delivering a finished foam solution which meets the applicable rate, range, and pattern standards of Table 3, Performance Parameters 5, 6, or 7, as applicable.

d. Each water/foam agent turret or ground sweep shall deliver a finished foam of a quality which meets the applicable standards of Table 4.

NOTE: All water/foam applicator performance requirements are based on the assumption that foam used to perform the tests is an approved foam concentrate, e.g., will pass the military AFFF foam specification 50 ft2 fire test and the burnback resistance test.

90. THROUGH 99. RESERVED.

CANCELLED

AC 150/5220-10B 10/20/97

Table 3. Extinguishing Agent System Performance Standards .

AGENT SYSTEM PERFORMANCE

PARAMETER VEHICLE CLASS "

0 ---- I. Dry Chemical Handline:

a. Discharge Rate ::: 5 Ibs per sec S 7 Ibs per sec b. Range At least 25 feet

2. Halotron I or approved equivalent Handline: a. Discharge Rate ::: 5 Ibs per sec S 7 Ibs per sec b. Range At least 25 feet 3. Reeled WaterlFoam Handline: a. NoŜle Flow Rate: ± 5% ::: 60 gpm (or 95gpm for 1 .25 in. i.d hose) b. Straight Stream Pattern ::: 50 ft reach c. Dispersed Stream Pattern ::: 20 ft reach and ::: 15 ft wide

4. Woven Jacket WaterlFoam Handline: a. Nozzle Flow Rate: ±5% ::: 95 gpm b. Straight Stream Pattern ::: 65 ft reach c. Dispersed Stream Pattern ::: 20 ft reach and ::: 15 ft wide 5. Turret Discharge:

a. *Flow Rate: (gpm), (-0%, +10%) 500 750 1,000 1,200 b. Stream Pattern/Distances (1) StraightlFar Point (ft) 160 190 230 250 (2) DispersedlFar Point (ft) 60 65 70 75

(3) Dispersed/Width (ft) 35 35 35

35

6. Ground Sweep: a. Flow Rate: (gallons/minute) At least 100 (-0%, +10%) b. Flat Pattern Distances: (1) Far Point (ft) ::: 30 ::: 30 ::: 30 ::: 30 (2) Width (ft) ::: 12 ::: 1 2 ::: 12 ::: 12

7. Bumper Turret: a. *Flow Rate: (gpm), (-0%, +10%) 250 300 300 300 b. Flat Patter Distances: (1) Near Point S Within 30 feet of front bumper

(2) Width (ft) ::: 20 ::: 30 ::: 30 ::: 30 (3) Far Point (ft) ::: 50 ::: 50 ::: 50 ::: 50

c. Straight Stream: Range at least 150 feet

8. Water Tank: Minimum Rate Capacity 1,000 1,500 2,500 3,000 and above Percent Deliverable:

a. On level, 100% 100% 100% 100% b. On 20% side slope, and on 75% 75% 75% 75% c. 30% ascending/descending grade 75% 75% 75% 75%

9. Dry Chemical Turret Discharge: a. Flow Rate: ::: 16 Ibs per second b. Range, Far Point: ::: 100 ft c. Width: > 17 ft

*NOTE: Roof mounted turrets may have flow rates reduced by up to 30% and elect to raise ground bumper turrets rate increased proportionally. For example, Class 2 , Turret 750 down to (525), Bumper 300 up to (525).

CANCELLED

1 0/20/97 AC 150/5220-IOB

Table 3M. Extinguishing Agent System Performance Standards (Metric) .

AGENT SYSTEM PERFORMANCE PARAMETER VEHICLE CLASS ---- I. Dry Chemical Handline:

a. Discharge Rate 2: 2.35 kg per sec ::: 3.3 kg per sec b. Range At least 7.5 m

2. Halotron I or approved equivalent Handline:

a. Discharge Rate 2: 2.3 kg per sec ::: 3.3 kg per sec b. Range At least 7.5 m

3. Reeled WaterlFoam Handline:

a. Nozzle Flow Rate: ± 5% 2: 227 Lpm b. Straight Stream Pattern 2: i5 m reach c. Dispersed Stream Pattern 2: 6 m reach and 2: 4.6 m wide 4. Woven Jacket WaterlFoam Handline: a. Nozzle Flow Rate: ± 5% 2: 360 Lpm b. Straight Stream Pattern 2: 19.5 m reach c. Dispersed Stream Pattern 2: 6 m reach and 2: 4.6 m wide 5. Turret Discharge: a. *Flow Rate: (Lpm), (-0%, +10%) 1,893 2,839 3,785 4,542 b. Stream PatternlDistance s (1) StraightlFar Point (m) 49 58 70

75

(2) Dispersed/Far Point (m) 1 8 19.5 21 22.5 (3) Dispersed/Width (m) 10.5 10.5 10.5 10.5

6. Ground Sweep: a. Flow Rate: (liters/minute) At least 379 (-0%, +10%) b. Flat Pattern Distances: (1) Far Point (m) 2: 9 2: 9 2: 9 2: 9 (2) Width (m) 2: 3.6 2: 3.6 2: 3.6 2: 3.6 7. Bumper Turret: a. *Flow Rate: (Lpm), (-0%, +10%) 946 1,135 1,135 1,135 b. Flat Patter Distances: (1) Near Point ::: Within 9 meters of front bumper

(2) Width (m) 2: 6 2: 9 2: 9 2: 9 (3) Far Point (m) 2: 1 5 2: 15 2: 15 2: 15

c. Straight Stream: Range at least 45 meters

8. Water Tank: Minimum Rated Capacity (liters) 3,785 5,678 9,463 1 1,355 and above Percent Deliverable:

a. On level, 100% 100% 100% 100% b. On 20% side slope, and on 75% 75% 75% 75% c. 30% ascending/descending grade 75% 75% 75% 75%

9. Dry Chemical Turret Discharge: a. Flow Rate: 2: 7 kg. per second b. Range, Far Point: 2: 30 meters c. Width: > 5 meters

*NOTE: Roof mounted turrets may have flow rates reduced by up to 30% and elect to raise ground bumper turrets rate increased proportionally. For example, Class 2 , Turret 750 down to (525), Bumper 300 up to (525).

CANCELLED

AC 1 5015220-10B 10/20/97

Table 4. Foam Quality Standards.

Foam Concentrate Type (1) (2)

Protein and Fluoroprotein Aqueous-Film-Forming-Foam

and Air-Aspirated Film-Forming Fluoroprotein Foam

Air-aspirated Nonaspirated

Expansion Minimum Minimum Minimum Minimum Minimum Ratio 25% Drain Expansion 25% Drain Expansion 25% Drain (Range) Time Ratio Time Ratio Time (minutes) (minutes) (minutes)

Ground 8-12 5 5 4 3 1 Sweeps

Handlines 8-12 5 5 4 3 1

Turrets 8-12 5 5 4 3 1

(1) The foams used to test the vehicle foam system performance are assumed to be foams that meet the industry standards for acceptable aircraft firefighting foams. For example, the non-film forming foams, e.g., proteinl[Juoroprotein foams, must be capable of passing Underwriters Standard UL-162 (Type 3 Application) and the film-forming-foams must be capable of passing at least the 50 ft2 fire extinguishment test and the burnback resistance test of MIL-F-24385.

(2) Foams that are labeled as "universal", "multi-purpose", ''polar solvent", "3%16%" or "alcohol foams" should not be used in an airport ARFF vehicle unless the ARFF vehicle is specifically designed with a proportioning system, foam storage tank, and piping intended to use this type of agent.

CANCELLED

1 0/20/97 AC 150/5220-10B

CHAPTER 4. QUALITY ASSURANCE.

Section 1. General Consideration.

100. CRITERIA FOR VEHICLE ACCEPTANCE. Compliance with this guide specification shall be documented by one more of the following methods:

a. Manufacturer's Certification.

(1) The ARFF vehicle manufacturer shall comply with this requirement by providing a signed, component manufacturer's application approval for the specific components listed in paragraph 103. The signed application approvals or a clear copy of the original shall be made part of the vehicle documentation package.

(2) The ARFF vehicle manufacturer shall provide a written certification that the specific subsystems listed in paragraph 1 04 comply with the applicable performance, design, or construction requirements of this guide specification. A signed copy of the certification shall be made part of the vehicle documentation.

b. Prototype Vehicle Tests.

(1) The tests specified in paragraph 1 05 shall be conducted by the manufacturer on the "first article," i.e., prototype vehicle, produced to meet the performance criteria of this guide specification. A mutually acceptable third party (independent testing laboratory/service) may be used to conduct the required tests.

(2) A copy of the signed test report(s) shall be made part of the vehicle documentation package. These tests need not be repeated for follow-on production vehicles. However, if substantive changes

in design are made or unusual options are requested, which could reasonably be expected to affect one or more of the required vehicle performance criteria, the applicable test shall be repeated.

(3) There shall be a tilt table side slope test of vehicles fitted with elevated boom type devices. The vehicle must meet the minimum side slope angle of the class vehicle, with the boom in the nested or bedded position. This test needs only be accomplished for the first test article vehicle or if significant relocation of weight distribution occurs due to other possible center

of gravity changes resulting from installation of specialized equipment such as generators

c. Vehicle Acceptance Tests.

(1) The tests listed in paragraph 121 shall be conducted by the ARFF vehicle manufacturer on evelY vehicle. These tests may be conducted at the manufacturer's facility, at the airport, or at another mutually acceptable test site.

(2) The results of these tests shall be recorded and signed by the test manager. A copy of the signed test report(s) shall be made part of the vehicle documentation package.

101. TECHNICAL SERVICE, PERFORMANCE DOCUMENTATION, AND TRAINING.

a. The vehicle documentation package shall include two copies each of an Operator's Manual, a Parts Manual, and the Maintenance/Service Manual

applicable to the specific vehicle. It shall also include one signed copy of each of the certification(s) and test report(s) required by paragraphs 1 00.a, b, and c.

(1) The Operator's Manual shall include all information required for the safe and efficient operation of the automotive chassis, the fire extinguishing equipment, and any special attachments or auxiliary equipment. The location and function of all controls and instruments shall be illustrated and described. The manual shall at least:

(a) Cover preparation of the vehicle for service upon receipt from the manufacturer.

(b) Give a general description of, and step-by-step instructions for, the operation of the vehicle and its fire extinguishing system(s).

(c) Provide checklists for the daily maintenance inspections and mission readiness checks that the operator is expected to perform.

(d) Provide schedules for preventative maintenance and required maintenance.

required

periodic

CANCELLED

AC 150/5220-10B

(2) The Parts Manual shall include illustrations and exploded views, as needed, to properly identify all parts, assemblies, subassemblies, and special equipment. All components of assemblies shown in illustrations or exploded views shall be

identified by reference numbers which correspond to the reference numbers in the parts lists. All purchased parts shall be cross-referenced with the original manufacturer's name and part number. The parts list shall indicate the quantity of each item used per vehicle. The manual shall contain an alphabetical and a numerical parts list in addition to a table of contents.

(3) The Maintenance/Service Manual shall identify any special tools and test equipment required and shall cover troubleshooting and maintenance as well as minor and major repair procedures. The text shall contain performance specifications, tolerances, and fluid capacities; current, voltage, and resistance data; hydraulic, pneumatic, and electrical diagrams; and such other illustrations and exploded views as may be required to permit proper maintenance by qualified mechanics. The manual shall contain an alphabetical subject index as well as a table of contents.

(4) The Certification Documents and Test Reports shall be bound or otherwise packaged in a manner suitable for filing.

b. The manufacturer shall, at no additional cost, provide trained personnel at the time of delivery and provide adequate training as specified by the purchaser for firefighter and/or airport personnel in its operation and maintenance. Training shall include written operating instructions that depict the step by step operational use of the vehicle. Written instructions shall include, or be supplemented by, materials which can be used to train subsequent new operators.

102. NAMEPLATES AND INSTRUCTION PLATES.

a. All nameplates and instruction plates shall be made of a material which is not degraded by weathering or exposure to water, firefighting agents, vehicle operating fluids, or hydrocarbon fuels and solvents. The information may be engraved, stamped, or etched on the plate. All plates shall be attached with screws, bolts, or rivets as may be appropriate for the location. Each plate shall be mounted in a conspicuous place on or near the item it identifies or for which it gives instructions.

b. Nameplates shall show make, model, serial number, and other such data as may be appropriate for positive item identification.

c. Instruction plates shall provide specific directions to be followed for safe, efficient operation, or servicing the vehicle or equipment. These plates shall include specific warnings or cautions as may be necessary to protect operation and maintenance personnel from such hazards as high voltage, pressure and temperature, sharp edges, moving parts, or hazardous materials. These plates shall be so located and of sufficient size to be readily seen under normal operating and service conditions. Instruction plates essential to the safe and effective operation of the vehicle and fire suppression system(s) shall be

illuminated for night operations. For example, there shall be a data plate visible to the driver that includes vehicle weights and dimensions and an inclinometer calibrated to indicate manufacturers safe dynamic side slope operation. Another data plate should list all fluid types and capacities for the intended use.

Section 2. Certification of Performance.

103. COMPONENT MANUFACTURER'S CERTIFICATION. A copy of the component manufacturer's certification (signed application approval) shall be provided for each of the following ARFF vehicle components:

a. Axles.

b. Complimentary Agent Pressure Relief Device.

c. Complimentary Agent Storage Container.

d. Engine(s); Prime Mover(s) and Pump, If Separate.

e. Handline Hose(s) with Couplings Attached.

f. Propellant Gas Cylinder(s).

g. Propellant Gas Cylinder Regulating Device.

h. Tires.

CANCELLED

i. Transfer Case.

j. Transmission.

k. Wheels.

104. VEHICLE MANUFACTURER'S CERTIFICATION. The vehicle manufacturer shall certify in writing that the following components or subsystems comply with the applicable requirements of this AC or a comparable, recognized standard:

AC 1 50/5220-IOB

Component: Paragraph Table 2 Number Item No. a. Brake

(1) Air Supply 32a(l) thru (5) None

(2) Emergency 32b 1 1

(3) Parking 32c 12

(4) Service 32d(l ) and (2) 10

b. Cooling System 44 None

e. Exhaust System 45 None

d. Fuel System 46 None

Section 3. Prototype Vehicle Performance.

105. PROTOTYPE TEST LIST. The tests listed below shall be conducted by the manufacturer, an agent of the manufacturer, or an independent agent or agency on the "first article" produced to meet the performance criteria of this guide specification or a comparable recognized standard. Should major modification such as a new suspension design, or major alteration such as installation of a high reach or extendible turret device be made to the vehicle, tests to certify compliance with Section 1 14, Stability: Dynamic and Static, must be repeated. The specific facilities, equipment, test conditions, test procedures, and the pass/fail criteria detailed in paragraphs 106 through 1 1 8 of this section

shall be used for each function to be tested.

a. Brake Systems:

(1) Grade Holding--Service and Parking

(2) Stop Distance--Service and Emergency

b. Complimentary Agent Systems:

(1) Handline Discharge Rate and Range

(a) Dry Chemical

(b) Halotron I or approved equivalent

(2) Propellant Gas

(3) Purge and Vent System

(4) System Pressure Regulation

e. Electrical Charging System

d. Flexibility of Body and Chassis

e. Foam/Water Agent System:

(1) Bumper Turret/Ground Sweep Discharge Rate, Range, and Pattern

(2) Flush Capability

(3) Handline wlNozzle Discharge Rate, Range, and Pattern

(4) Proportioning and Foam Quality

(5) Pump and Roll Capability

(6) Pump Total Discharge Capacity

(7) Roof Turret(s):

(a) Azimuth and Elevation Limits, Control, and Indicator

(b) Control System Resistance

(e) Discharge Rate, Range, and Pattern

(8) Tank(s):

CANCELLED

AC 1 50/5220-lOB

(a) FiIl--Overflow and Vent Capacity

(b) Minimum Rated Capacity

(9) Undertruck Nozzle Pattern

f. Gradability

g. Radio Interference Suppression

h. Siren Output: Direction and Magnitude

i. Stability:

(1) Dynamic/Turning Control

(2) Static/Side Slope Stability

j. Steering System:

(1) Resistance/Operating Force Requirements

(2) Wall-To-Wall Turning Diameter

k. Underbody Clearances

I. Visibility: Included Angles From Driver's Seat

m. Vehicle Interior Noise Levels

106. BRAKE SYSTEMS PERFORMANCE.

a. Facilities.

(1) Tests 1 and 2 require two ramps or inclines (man made or natural) known to be 20 percent and 50 percent grades.

(2) Tests 3 and 4 may be conducted on any paved surface that can support the vehicle weight and the resulting braking forces and is long enough to allow for the combined acceleration, constant speed, and safe braking distance. The site shall be marked out in a lane that is the width of the vehicle to be tested, plus four feet ( 1 .2 m).

(3) A runway or taxiway with a marked center line that meets the length, strength, and other conditions specified is an acceptable alternative test site.

1 0/20/97

b. Equipment.

(1) Tests 3 and 4 require a calibrated fifth wheel connected to a ground speed readout device which is accurate to ±0.5 percent of the actual measured speed.

(2) Tests 3 and 4 require a brake triggered device which will mark the strip recorder to show initial brake application.

(3) Tests 3 and 4 require a strip recorder with sufficient resolution to record the vehicle speed, brake application point, and stop point with the same accuracy as that required for the fifth wheel.

NOTE: The use of other data collecting/recording devices of equal accuracy and precision is acceptable.

(4) A test report notebook or similar record form to be used as a test report work sheet and incorporated into the documentation package for the specific vehicle.

c. Test Conditions.

(1) The grades used for Tests 1 and 2 shall be dry, smooth, free of loose material, and long enough to accommodate the length and strong enough to hold the fully loaded vehicle.

(2) The vehicle shall be fully loaded. Ballast shall be used as needed to account for the crew and equipment allowance. The ballast shall be arranged so as to distribute the weight in a manner that closely simulates the items being represented. The ballast shall NOT be shaped or distributed in a manner that creates a favorable, artificial center of gravity.

(3) The brakes shall be burnished and adjusted to the manufacturer's specifications.

(4) The tires shall be inflated to the manufacturer's recommended cold inflation pressure.

(5) The surface of the site for Test 3 and 4 shall be level, dry, smooth, and free of any loose material.

CANCELLED

10120/97

d. Test Procedures.

(1) TEST-I. Grade Holding--Parking Brake.

(a) Drive the vehicle in the forward direction up the 20 percent grade, stop the vehicle with using the service brake, and set the parking brake.

(b) Shift the transmission to neutral, release the service brake, and monitor the vehicle visually for 5 minutes for any perceptible wheel rotation. Record the results.

(c) Repeat steps (a) and (b) except that the vehicle shall be backed up the grade.

(2) TEST-2. Grade Holding--Service Brake.

(a) Drive the vehicle in the forward direction up the 50 percent grade and stop the vehicle with the service brake.

(b) Continue holding the vehicle with the service brake, shift the transmission into neutral, and monitor the vehicle visually for 5 minutes for any perceptible wheel rotation. Record the results.

(c) Repeat steps (a) and (b) except that the vehicle shall be backed up the grade.

(3) TEST-3. Stop Distance--Service Brake.

(a) Start the vehicle, tum on the strip recorder, accelerate to 20 mph (32 km/h), and maintain that speed for at least 50 feet (15 m).

(b) Apply the service brake as if in a panic stop; hold the brake on until the vehicle stops. Record the printout of the distance traveled from the initial braking until the vehicle came to a stop. No steering corrections shall be made for vehicle drift during the stop.

(c) Measure and record the perpendicular distance from the nearest lane edge line to the outer most edge of the vehicle's width. Report the measurement as a negative number ifthe vehicle' is outside of the test lane; OR,

(d) If the test lane has a marked center line, measure and record the perpendicular distance

AC 150/5220-IOB

from the centerline to the outer most edge of the vehicle that is farthest from the center line of the test lane.

(e) Repeat the steps (a) through (d) for two complete cycles in each direction of the test lane; record each braking distance for 20 mph (32 km/h).

(f) Repeat steps (a) through (e) above except that the test speed shall be 40 mph (64 km/h).

(4) TEST-4. Stop Distance--Emergency Brake. Repeat Test-3, steps (a) through (e) above for the emergency brake except that only the 40 mph (64km/h) test speed shall be used.

(5) TEST-5. Circuit Failure--Service Brake.

(a) Disable one dual brake circuit and repeat Test-3, steps (a) through (e) for the service brake at a speed of 40 mph (64 km/h).

(b) Reconnect the first circuit, disconnect the second, and repeat Test-3, steps (a) through (e) on the second service brake circuit at 40 mph (64 km/h),

e. Pass/Fail Criteria.

(1) The service and parking brake grade holding performance shall comply with the applicable portions of paragraph 32 and the applicable standards of table 2, Performance Parameters 10 and 12.

(2) For all stop tests conducted in a lane with outer boundary markers, NO portion of the vehicle shall be outside those boundaries after the vehicle stops.

(3) For all stop tests conducted in a lane with a marked centerline, the measured distance from the outer most portion of the vehicle to the centerline of the lane shall be less than one-half of the vehicle width, plus 2 feet (0.6 m).

(4) Each of the four recorded stop distances for the service and emergency brakes shall meet the applicable stopping distance standards of table 2, Performance Parameters 10 and 1 1 .

(5) Each of the four recorded stop distances, for each circuit, for the split circuit service brake test

shall meet the applicable stopping distance standards

CANCELLED

AC 150/5220-I OB

of Table 2, Performance Parameters 1 1, Emergency Brake.

107. COMPLEMENTARY AGENT SYSTEM.

NOTE: If the vehicle manufacturer provides signed test data that verifies system performance, or a performance certificate from a third party for a complementary agent system of the same brand, general size, and flow rate, or similar documentation from the actual complementary agent system manufacturer, that documentation may be submitted as an additional item under the terms of paragraphs 1 00 and 103 and the test requirements of this paragraph (but not the pass fail/criteria) shall be waived.

a. Facilities for Agent System Test Series Tests- 1, 2, and 3 require a level, open site (free of obstructions within the expected agent range) that is suitable for the discharge of approximately 500 pounds (230 kg) of the complementary agent being tested.

b. Equipment for the Complimentary Agent System Test Series.

(1) Tests 1 , 2, and 3 require a means of removing the agent tank from the vehicle without loss of agent and moving it to the weighing device.

NOTE: Alternatively, the system may be tested as a unit outside the vehicle providing that the agent tank, related piping, fittings, valves, hose and nozzle(s) are in the same configuration as they will be in when installed on the vehicle. OR, the system may be tested as an integral part of the completed prototype vehicle as long as the weighing device meets the requirements of paragraph 107.b.(2).

(2) A calibrated scale or load cell with an accuracy of ± 1 percent of the amount of agent to be weighed.

(3) A stopwatch which can be read to ± 0.5 seconds.

(4) A tape measure or other distance measuring device that can be read to ± 0.5 inches.

(5) An anemometer capable of reading wind velocities in the range of 0 to 1 0 mph (0 to 16 km/h) with ± 0.5 mph (0.8 km/h) accuracy.

(6) Test-4 requires a means of connecting a pressure gauge or transducer between the low pressure (downstream) side of the regulator and the agent tank

inlet valve.

(7) Test-4 requires a calibrated pressure sensing device capable of reading pressure with an accuracy of ± 1 percent of the pressure to be measured.

(8) Test-4 requires a pressure reading device connected to the piping between the low pressure propellant gas inlet valve and the agent tank top. If the tank is equipped with a gauge having sufficient accuracy, it may be used.

(9) A test report notebook or similar record form to be used as a test report work sheet and incorporated into the documentation package.

c. Test Conditions for Agent System Series.

(1) The complimentary agent tank pressure relief device shall have been certified as required in paragraph 1 03.b and shall be operational.

(2) The agent tank shall have been certified as required in paragraph 103.c and shall be clean, dry, and empty.

(3) Propellant gas tanks shall have been certified as required in paragraph 103.f and shall be pressurized to the recommended operational pressure.

(4) Wind conditions shall be in the range of 0 to 5 mph (0 to 1 0 km/h).

(5) The vehicle (or alternative test unit) shall have all agent piping operational.

d. Test Procedures.

(1) TEST-I. Handline Discharge Rate and Range.

NOTE: This test may be combined with Test-4 if sufficient agent remains in the tank.

(a) Charge the agent tank using the manufacturer's recommended agent and fill procedure. Weigh it and record the gross filled weight.

(b) Reconnect the tank to the system and ensure that fill cap(s) are secure, propellant gas lines

CANCELLED

are connected, discharge nozzles are in the closed position, and that all fittings and connections are tight.

(c) Pull all handline hose from the reel(s), position nozzles so that they may be discharged onto the test site with no stream obstructions and such that the stream patterns will not overlap. Pressurize the system using the manufacturers recommended procedure.

(d) Select one of the handline nozzles and hold it in a fixed, horizontal position between 36 and 60 inches (90 and 150 cm) above the ground level. Simultaneously start the stopwatch and fully open the nozzle.

(e) Monitor the time, and after approximately 20 seconds of discharge time has elapsed, simultaneously shut down the nozzle and stop the stopwatch.

Continue reading ↓ 120 of 256 passages shown